Allowable deviation in shear stand installation

Item deviation (mm)

Elevation ± 0.50

Horizontal center line 1.00


1

Vertical center line 1.00

Single base 0.10/1000

2 Levelness Between
0.10/1000
two bases

Side of

Parallelism reference 0.10/1000

relative to base
3
shear center Side

line between two 0.10/1000

bases

Allowable deviation in shear installation

Allowable
Item Item Measured Value
deviation (mm)

Stand

window 0.20/1000

1 Perpendicularity surface

Stand side 0.20/1000


Rolling
0.10/1000
direction

Vertical

2 Levelness rolling 0.20/1000

direction

Between two
0.20/1000
stands

3 Stand center line 1.0

No feeler gauge

gap for 70% of


Contact gap between stand and
4 the periphery and
base
gap of 0.05 is

allowed locally