1 sec.
The over-rising in
temperature of the fixing
E001- assembly is detected. - Clear the error in service mode
0010 The power is turned off (COPIER>FUNCTION>CLEAR>ERR).
and then on without
clearing the error.
- Check if the connector (J505) of the DC controller PCB is
The rise in temperature
mounted properly and also check if the connector of the fixing
of the fixing assembly is
assembly is mounted properly. - Check the wiring between
faulty.
the thermistor and the DC controller. -Check if the main
E002- The reading of the main
thermistor is mounted properly and also check if there is no
0000 thermistor (TH1) does
contamination. - Replace the main thermistor. - Replace the
not reach 100 deg C 2
fixing heater. - Replace the AC driver PCB. - Replace the DC
min 30 sec after it has
controller PCB. Caution You must clear the error in service
exceeded 70 deg C.
mode (COPIER>FUNCTION>CLEAR>ERR).
- Check if the connector (J505) of the DC controller PCB is
The rise in temperature
mounted properly and also check if the connector of the fixing
of the fixing assembly is
assembly is mounted properly. - Check the wiring between
faulty.
the thermistor and the DC controller. -Check if the main
E002- The reading of the main
thermistor is mounted properly and also check if there is no
0001 thermistor does not
contamination. - Replace the main thermistor. - Replace the
reach 150 deg C within 2
fixing heater. - Replace the AC driver PCB. - Replace the DC
min 30 sec after it has
controller PCB. Caution You must clear the error in service
exceeded 100 deg C.
mode (COPIER>FUNCTION>CLEAR>ERR).
The rise in temperature
of the fixing assembly is
faulty.
E002- - Clear the error in service mode
The power has been
0010 (COPIER>FUNCTION>CLEAR>ERR).
turned off and then on
without clearing the
error.
- Check if the connector (J505) of the DC controller PCB is
The fixing temperature is
mounted properly and also check if the connector of the fixing
too low after a standby
assembly is mounted properly. - Check the wiring between
state.
the thermistor and the DC controller. -Check if the main
E003- The reading of the main
thermistor is mounted properly and also check if there is no
0000 thermistor is 70 deg C or
contamination. - Replace the main thermistor. - Replace the
lower for 2 sec or more
fixing heater. - Replace the AC driver PCB. - Replace the DC
after it has reached 100
controller PCB. Caution You must clear the error in service
deg C.
mode (COPIER>FUNCTION>CLEAR>ERR).
The fixing temperature is
too low after a standby
E003- state. - Clear the error in service mode
0010 The power has been (COPIER>FUNCTION>CLEAR>ERR).
turned off and then on
without clearing the
3
error.
The fixing assembly is
faulty.
- Replace the AC driver PCB. - Replace the DC controller
E004- The SSR used to drive
PCB. Caution You will have to clear the error in service mode
0000 the fixing heater has a
(COPIER>FUNCTION>CLEAR>ERR).
short circuit (detection by
hardware circuitry).
The absence of the fixing
web is detected.
The length of the fixing - Check the position of the fixing web detection lever. -
web that has been taken Replace the fixing web. - Replace the fixing web length
E005- up is more than a sensor. - Replace the DC controller PCB. Caution After
0000 specific value and the replacing the fixing web, you will have to clear the two web
fixing web length sensor counters in service mode (COPIER>COUNTER>MISC>FIX-
(PS7) has detected the WEB and COPIER>COUNTER>DRBL-1>FIX-WEB).
absence of the web for 5
sec or more.
The absence of the fixing
web is detected. - Reset the counters of the two webs to zero in service mode
E005-
The power is turned off (COPIER>COUNTER>MISC>FIX-WEB,
0010
and then on without COPIER>COUNTER>DRBL-1>FIX-WEB)
clearing the error.
0001 fan (1/2) is faulty. assembly of the laser cooling fan 1. - Check if the
The lock signal arrives for 5 sec connector (J503) of the relay PCB is mounted
or more although the laser properly. - Replace the laser cooling fan 1. - Replace
cooling fan 1 (FM3) is being the DC controller PCB.
driven.
The rotation of the laser cooling
- Check if there is no foreign material in the rotation
fan (1/2) is faulty.
assembly of the laser cooling fan 2. - Check if the
E121- The lock signal arrives for 5 sec
connector (J503) of the relay PCB is mounted
0002 or more although the laser
properly. - Replace the laser cooling fan 2. - Replace
cooling fan 2 (FM5) is being
the DC controller PCB.
driven.
Caution No code will be indicated. The keys will be
There is an error in the detection
locked. You can check the code in service mode
of the scanner home position.
(COPIER>DISPLAY>ERR). - Check if the scanner
Scanner home position cannot be
E202- motor is connected properly, and replace the scanner
detected within a specific period
0000 motor if necessary. - Check if the connector (J1720)
of time after the power switch is
of the relay PCB is mounted properly. - Replace the
turned on or the Start key is
scanner home position sensor. - Replace the reader
pressed.
controller PCB.
There is an error in the detection
of the image leading edge signal.
Caution No code will be indicated. The keys will be
During forward movement in fixed
locked. You can check the code in service mode
reading mode or during a home
(COPIER>DISPLAY>ERR). - Check if the scanner
E204- position search, the image
motor is connected properly, and replace the scanner
0000 leading signal does not occur; or,
motor if necessary. - Replace the scanner image
in stream reading mode, the
leading edge sensor. - Replace the reader controller
image leading edge signal does
PCB.
not arrive from the ADF controller
PCB.
The rise in temperature of the
scanning lamp heater is faulty.
While the power is ON, the
ambient temperature of the
- Check if the connecter (J852, J853) of the light
scanning lamp does not exceed
E211- control PCB is mounted properly. - Replace the
10 deg C 2 min after the
0000 scanning lamp heater. - Replace the light control
florescent heater has gone ON;
PCB. - Replace the reader controller PCB.
or, after the power is turned on,
the reading of the ambient
temperature of the scanning lamp
is 0 deg C or lower.
The rise in temperature of the
scanning lamp heater is faulty. - Check if the connecter (J852, J853) of the light
E215- While the scanning lamp is OFF, control PCB is mounted properly. - Replace the
0000 the reading of the ambient scanning lamp heater. - Replace the light control
temperature is 170 deg C or PCB. - Replace the reader controller PCB.
higher.
E218- The scanning lamp is not - Check if the scannning lamp is mounted properly. -
8
0000 mounted properly. Check if the connecter (J1002, J1003) of the inverter
When the power is turned on, the PCB is mounted properly. - Check if the connector
absence of the scanning lamp is (J1720) of the relay PCB is mounted properly. -
detected. Replace the scanning lamp. - Replace the reader
controller PCB.
The scanning lamp life
- Check if the connecter (J852, J853) of the light
While the scanning lamp is ON,
E219- control PCB is mounted properly. - Replace the
the reading of the ambient
0000 scanning lamp heater. - Replace the light control
temperature is 170 deg C or
PCB. - Replace the reader controller PCB.
higher.
contents.
There is an error in the initialization of the
IPC.
E710- - Check the cable. - Replace the reader
The IPC (IC5) on the reader controller PCB
0001 controller PCB.
cannot be initialized when the main power
supply is turned on.
There is an error in the initialization of the
IPC.
E710- - Check the cable. - Replace the DC
The IPC (IC40) on the DC controller PCB
0002 controller PCB.
cannot be initialized when the main power
supply is turned on.
There is an error in the initialization of the
IPC.
E710- - Check the cable. - Replace the main
The IPC (IC1003) on the machine controller
0003 controller PCB.
PCB cannot be initialized when the main
power is turned on.
There is an error in the IPC communication.
E711- Data has been written to the error register of - Check the cable. - Replace the reader
0001 the IPC (IC5) on the reader controller PCB 4 controller PCB.
times or more within 1.5 sec.
There is an error in the IPC communication.
E711- Data has been written to the error register of - Check the cable. - Replace the DC
0002 the IPC (IC40) on the DC controller PCB 4 controller PCB.
times or more within 2 sec.
There is an error in the IPC communication.
E711- Data has been written to the error register of - Check the cable. - Replace the main
0003 the IPC (IC1003) on the main controller PCB controller PCB.
4 times or more within 2 sec.
- Check if the communication cable
Communication error with the ADF
E712- between the ADF and copier is connected
The communication IC (IPC) on the ADF
0000 properly. - Replace the ADF controller
controller PCB goes out of order.
PCB.
because of an error.
There is an error in the
communication with the NE controller.
An IPC error has occurred while the Check the cable; thereafter, reset the condition in
E717-
NE controller is in operation. There is service mode:
0002
an open circuit for the IPC. An error COPIER>FUNCTION>CLEAR>ERR.
has occurred, and the IPC
communication remains disabled.
There is a coin vendor error.
The coin vendor is not connected
Check the cable; thereafter, reset the condition in
E719- when the power is turned on,
service mode:
0001 although it was connected before the
COPIER>FUNCTION>CLEAR>ERR.
power was turned off because of an
error.
There is a coin vendor error.
While the coin vendor is in operation,
an IPC error has occurred, IPC has
developed an open circuit, or an error Check the cable; thereafter, reset the condition in
E719-
preventing recovery of IPC service mode:
0002
communication has occurred. An COPIER>FUNCTION>CLEAR>ERR.
open circuit ha been detected in the
line for the pickup/delivery signal. An
illegal signal has been detected.
There is a coin vendor error.
Check the cable; thereafter, reset the condition in
E719- While the unit price is being checked
service mode:
0003 at startup, an error occurs in the
COPIER>FUNCTION>CLEAR>ERR.
communication with the coin vendor.
There is a coin vendor error.
An error has occurred at new card
Check the cable; thereafter, reset the condition in
E719- reader startup. The new card reader
service mode:
0011 is not connected when the power is
COPIER>FUNCTION>CLEAR>ERR.
turned off, although it was connected
when the power was turned off.
There is a coin vendor error.
An IPC error has occurred at new
Check the cable; thereafter, reset the condition in
E719- card reader startup. There is an IPC
service mode:
0012 open circuit. An error has occurred
COPIER>FUNCTION>CLEAR>ERR.
that prevents recovery of IPC
communication.
E730- There is a PDL software error. - Execute PDL resetting. - Turn on the power
1001 An initialization error has occurred. once again.
There is a PDL software error.
E730- An error that may be critical to the - Execute PDL resetting. - Turn on the power
100A system (e.g., failed initialization) has once again.
occurred.
E730- There is a PDL software error. - Turn on the power once main. - Check the
13
9004 There is an error in the connection of the open I/F board and the cable. -
communication (PAI) with an external Replace the board for the external controller
controller. open I/F. - Replace the main controller PCB.
- Turn on the power once main. - Check the
There is a PDL software error.
E730- connection of the open I/F board and the cable. -
Fault in the connector of the vide
9005 Replace the board for the external controller
cable to the external controller
open I/F. - Replace the main controller PCB.
- Execute PDL resetting. - Turn on the power
There is a PDL software error.
E730- once again. - Check the connection of the UFR
The PDL board does not respond. A
A006 board. - Re-install the firmware. - Replace the
subbootable is faulty or absent.
main controller PCB.
There is a PDL software error.
There is a mismatch between the - Execute PDL resetting. - Turn on the power
E730-
control software of the machine and once again. - Execute system formatting (all),
A007
the PDL control software in regard to and reinstall the system.
version.
- Turn on the power once again. - Re-install the
E730- There is a PDL software error.
Software. - Execute system formatting (all), and
B013 Corruption in the font data
reinstall the system.
error.
(COPIER>FUNCTION>CLEAR>ERR)
The power has been turned on without
resetting the error.
Disconnect and then connect J508 of the DC
The fixing unit temperature is abnormally
controller PCB. Disconnect and then connect
low. After correcting the fault, be sure to
the connectors of the fixing unit. Check the
reset the error.
E003- wiring between the main/sub thermistor and
(COPIER>FUNCTION>CLEAR>ERR)
0000 the DC controller PCB. Check the
The reading of the main thermistor has
mounting/soiling of the main thermistor.
exceeded 100 deg C, but is 70 deg C or
Replace the fixing heater. Replace the AC
less for 2 sec thereafter.
driver PCB. Replace the DC controller PCB.
The fixing unit has a fault. (protective
circuit ON) After correcting the fault, be
sure to reset the error.
E004- Replace the AC driver PCB. Replace the DC
(COPIER>FUNCTION>CLEAR>ERR)
0000 controller PCB.
While the sub heater is on, the SSR for
the heater drive has a short-circuit for 5
sec or more.
The fixing unit has a fault. (protective
circuit ON) After correcting the fault, be
sure to reset the error.
E004- Replace the AC driver PCB. Replace the DC
(COPIER>FUNCTION>CLEAR>ERR)
0001 controller PCB.
While the main heater is on, the SSR for
the heater drive has a short-circuit for 5
sec or more.
Check the position of the fixing web detecting
The fixing web has run out. After
lever. Replace the fixing web. Replace the
correcting the fault, be sure to reset the
fixing web length sensor. Replace the DC
E005- error.
controller PCB. If you have replaced the fixing
0000 (COPIER>FUNCTION>CLEAR>ERR)
web, be sure to reset the counter: -
The absence of the fixing web has been
COPIER>COUNTER>MISC>FIX-WEB -
detected for 5 sec or more.
COPIER>COUNTER>DRBL-1>FX-WEB
The fixing web has run out. After
correcting the fault, be sure to reset the
E005- error. Reset the error.
0010 (COPIER>FUNCTION>CLEAR>ERR) (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then
on without resetting the error.
0002 buffer motor rotation is faulty. The toner feed (J504, J511) of the DC controller PCB.
motor (sub hopper) rotation is faulty. After Replace the buffer motor (M18). Replace
correcting the fault, be sure to reset the error. the following: magenta roller drive clutch
(COPIER>FUNCTION>CLEAR>ERR) (CL1), toner transport motor (sub hopper;
The absence of toner in the buffer is detected M22), toner transport clutch (sub hopper;
for 60 sec even after toner supply operation CL23), buffer inside toner sensor (TS1),
for the buffer has been executed and when buffer inside toner lower limit sensor
there is toner inside the hopper. (TS2).
The developing assembly is out of toner. The
Disconnect and connect the connector
buffer motor rotation is faulty. The toner feed
(J504, J511) of the DC controller PCB.
motor (sub hopper) rotation is faulty. After
Replace the buffer motor (M18). Replace
correcting the fault, be sure to reset the error.
the following: magenta roller drive clutch
E020- (COPIER>FUNCTION>CLEAR>ERR)
(CL1), toner transport motor (sub hopper;
0003 The absence of toner inside the buffer is
M22), toner transport clutch (sub hopper;
detected for 210 sec or more even when
CL23), buffer inside toner sensor (TS1),
there is toner inside the sub hopper and after
buffer inside toner lower limit sensor
toner supply operation of that buffer following
(TS2).
the replacement of the toner bottle.
The developing assembly is out of toner. The
buffer motor rotation is faulty. The toner feed Disconnect and connect the connector
motor (sub hopper) rotation is faulty. After (J504, J511) of the DC controller PCB.
correcting the fault, be sure to reset the error. Replace the buffer motor (M18). Replace
(COPIER>FUNCTION>CLEAR>ERR) the following: magenta roller drive clutch
E020-
The absence of toner inside he buffer is (CL1), toner transport motor (sub hopper;
0004
detected for 150 sec or more even when M22), toner transport clutch (sub hopper;
there is toner inside the buffer and after toner CL23), buffer inside toner sensor (TS1),
supply operation has been executed for the buffer inside toner lower limit sensor
buffer following the replacement of the toner (TS2).
bottle.
The developing assembly is out of toner. The
buffer motor rotation is faulty. The toner feed
motor (sub hopper) rotation is faulty. After
correcting the fault, be sure to reset the error. Disconnect and then connect the
E020- (COPIER>FUNCTION>CLEAR>ERR) connector (J504) of the DC controller
0005 When installation mode PCB. Replace the developing assembly
(COPIER>FUNCTION>INSTALL>TONER-S) inside toner sensor (TS3).
is executed, the developing assembly inside
toner sensor does not detect the presence of
toner
The developing assembly is out of toner. The
buffer motor rotation is faulty. The toner feed
motor (sub hopper) rotation is faulty. After
Disconnect and then connect the
correcting the fault, be sure to reset the error.
E020- connector (J504) of the DC controller
(COPIER>FUNCTION>CLEAR>ERR)
0006 PCB. Replace the developing assembly
When installation mode
inside toner sensor (TS3).
(COPIER>FUNCTION>INSTALL>TONER-S)
is executed, the developing assembly inside
toner sensor detects the presence of toner,
20
E025- The toner bottle motor rotation is faulty. Disconnect and then connect J512 of the
0001 The toner bottle motor is not connected. DC controller PCB.
The copy data controller/NE controller Disconnect and then connect J1022 of the
E032- counter fails to operate. main controller PCB. Replace the copy data
0001 An open circuit of the counter signal has controller/NE controller. Replace the main
been detected. controller PCB.
The rotation of the pickup motor of the side
paper deck is faulty.
The side paper deck pickup motor has Disconnect and then connect J101 and
gone on, but the PLL lock signal is not J106 of the side paper deck driver PCB.
E043-
detected for 2 sec or more (1st detection). Replace the pickup motor. Replace the side
0000
MEMO: For the 2nd and subsequent paper deck driver PCB. Replace the DC
detection, the machine will indicate "E043" controller PCB.
on the screen offering a choice of sources
of paper.
The horizontal registration HP detection
has an error.
After the start of horizontal registration HP At the start of horizontal registration
detection, the HP sensor is not off within 5 detection in the course of printing, the
E051-
sec (i.e., not leaving home position). horizontal registration detection operation
0001
MEMO: If an error is detected in the course for downstream paper does not end within 5
of horizontal registration HP detection at sec.
power-on, the machine will indicate the
presence of a jam.
The horizontal registration HP detection
has an error.
After the start of horizontal registration HP At the start of horizontal registration
detection, the home position is not detection in the course of printing, the
E051-
detected within 5 sec. MEMO: If an error is horizontal registration detection operation
0002
detected in the course of horizontal for downstream paper does not end within 5
registration HP detection at power-on, the sec.
machine will indicate the presence of a
jam.
The horizontal registration HP detection
has an error. At the start of horizontal registration
Replace the horizontal registration HP detection in the course of printing, the
E051-
sensor. Replace the horizontal registration horizontal registration detection operation
0003
motor. Replace the stackless transport for downstream paper does not end within 5
driver PCB. Replace the DC controller sec.
PCB.
The high-voltage output has a fault. Remove and then mount the primary
(primary charging assembly) charging assembly. Check for soiling.
E065-
A fault (leak) is detected when high voltage Disconnect and then connect T601, J723,
0000
is supplied to the primary charging and J731 of the HV-DC PCB. Replace the
assembly. HV-DC PCB.
E067- The high-voltage output has a fault. Remove and mount the primary charging
0000 A fault is detected at the same time in 2 of assembly. Remove and mount the pre-
22
the following: primary high voltage, pre- transfer charging assembly. Remove and
transfer high voltage, transfer high voltage, mount the transfer/ separation charging
separation high voltage. assembly. Disconnect and then connect
J721, J723, J731, and J734 of the HV-DC
PCB. Replace the HV-DC PCB. Replace the
HV-AC PCB.
Remove and mount the transfer/separation
charging assembly. Disconnect and then
The high-voltage output has a fault.
connect J7233 and J734 of the HV-DC
(separation charging assembly)
E068- PCB. Disconnect and then connect J741
A fault (leak) has been detected while the
0000 and J742 of the HV-AC PCB. Replace the
separation charging assembly is being
HV-AC PCB. Replace the transfer/
supplied with high voltage.
separation charging assembly. Replace the
pre-transfer charging assembly.
Remove and mount the transfer/separation
The transfer high voltage has an error. charging assembly. Check for soiling.
E069- A fault (leak) has been detected while the Disconnect and then connect T701 and
0000 transfer charging assembly is being J723 of the HV-DC PCB. Replace the HV-
supplied with high voltage. DC PCB. Replace the pre-transfer charging
assembly.
A read error has occurred in relation to the Disconnect and then connect the connector
E102- laser scanner unit EEPROM data. of the video PCB. Disconnect and then
0001 The correction data cannot be read from connect the DC controller PCB. Replace the
the EEPROM of the laser scanner unit. laser scanner unit.
Check to see if all covers have been
attached to the primary charging assembly.
The laser scanner motor rotation has a Disconnect and then connect J764 of the
fault. laser scanner motor drive PCB (in the laser
E110-
After the laser scanner motor has gone on, scanner unit). Disconnect and then connect
0000
the PLL lock signal of the motor is not J1401 of the video PCB. Disconnect and
detected for 15 sec or more. then connect J506 of the DC controller PCB.
Replace the laser scanner unit. Replace the
video PCB. Replace the DC controller PCB.
0200 The open I/F relay PCB has detected between the main controller and PS controller).
an error (no recovery after a retry).
E315- The image data codec has a fault. Turn off and then back on he power. Replace
0300 Cubic time-out the main controller PCB.
E315- The image data codec has a fault. Turn off and then back on he power. Replace
0400 Shift Device A time-out the main controller PCB.
E315- The image data codec has a fault. Turn off and then back on he power. Replace
0401 Shift Device B time-out the main controller PCB.
An error has occurred in the main
E351- controller communication.
Replace the main controller PCB.
0000 At start-up, a main controller
communication error has occurred.
An ADF communication error has Disconnect and then connect the connector.
E400-
occurred. Replace the reader controller PCB. Replace
0001
A check sum error has occurred. the ADF controller PCB.
An ADF communication error has Disconnect and then connect the connector.
E400-
occurred. Replace the reader controller PCB. Replace
0002
A reception status error has occurred. the ADF controller PCB.
An ADF communication error has
Disconnect and then connect the connector.
E400- occurred.
Replace the reader controller PCB. Replace
0003 A reception interrupt error has
the ADF controller PCB.
occurred.
sensors within 2 sec after the sensor (PI7). Replace the ADF controller PCB.
pickup motor is driven: - pickup
roller height sensor 1 (PI8), pickup
roller height sensor 2 (PI9) - pickup
roller HP sensor (PI7)
The ADF shift motor rotation is Disconnect and then connect the connector.
E413-
faulty. Replace the shift motor HP sensor. Replace the
0001
The shift motor HP sensor is open. shift motor.
The ADF shift motor rotation is Disconnect and then connect the connector.
E413-
faulty. Replace the shift motor HP sensor. Replace the
0002
Shift motor HP sensor is closed. shift motor.
An ADF EEPROM read error has
occurred.
E420-
At power-on, an attempt to read the Replace the ADF controller PCB.
0000
EEPROM backup data fails. Or,
data that has been read has a fault.
E490-
The ADF is of the wrong type. Replace the ADF.
0001
E602 The HDD has an error.
The time memory (DDR-SDRAM)
E604- is faulty or inadequate.
Replace the DDR-SDRAM.
0000 A DDR-SDRAM (1 GB) of
adequate capacity is not detected.
The HDD temperature is
abnormally low.
E609-
At start-up, the HDD does not Replace the HDD.
0008
reach a specific temperature within
a specific time.
The HDD temperature is
abnormally low.
E609-
When returning from sleep mode, Replace the HDD.
0009
the HDD does not reach a specific
temperature within a specific time
E610 The HDD encryption key is faulty.
Turn off and then back on the power. (Turn off the
An error has occurred in the
machine and its delivery accessories; then, turn
communication between the
back on all accessories and then the machine.)
E711- pickup/delivery accessory and the
Connect the communication cables and terminals
0001 printer unit.
between the machine and the delivery accessories
The communication controller has
once again. Replace the accessories controller
detected a fault.
PCB. Replace the transceiver PCB.
An error exists in the Disconnect and then connect the connectors
E712- communication between the ADF between the reader unit and the ADF. Replace the
0001 and the reader unit. reader controller PCB. Replace the ADF controller
As much as 5 sec or more has PCB.
27
0012 the coin vendor/card reader. After correcting the connector of the main controller
fault, be sure to reset the error. PCB. Install the card reader. Replace
(COPIER>FUNCTION>CLEAR>ERR) the card reader.
In the communication with the card reader, an
error that cannot be reset has occurred (e.g.,
cable break).
A PDL-related error has occurred.
E730- Reset the PDL mechanism. Turn off
An initialization error has occurred at the start of a
1001 and then on the power.
job.
A PDL-related error has occurred.
E730- Reset the PDL mechanism. Turn off
An error has occurred in the communication with
100A and then on the power.
an external controller.
A PDL-related error has occurred. Turn off and then on the power.
E730-
A fault has been detected in the cable connection Replace the external controller relay
9004
with an external controller. PCB. Replace the external controller.
A PDL-related error has occurred. Turn off and then on the power.
E730-
A fault has been detected in the cable connection Replace the external controller relay
9005
with an external controller. PCB. Replace the external controller.
Reset the PDL mechanism. Turn off
E730- A PDL-related error has occurred. and then on the power. Reinstall the
A006 The PDL mechanism does not respond. system software. Replace the main
controller.
A PDL-related error has occurred. Reset the PDL mechanism. Turn off
E730- At start-up, the version of the machine control and then on the power. Reinstall the
A007 software and that of the PDL control software do system software. Replace the main
not match. controller.
Turn off and then on the power.
E730- A PDL-related error has occurred. Reinstall the system software.
B013 The font data is corrupted at start-up. Execute full formatting of the HDD,
and reinstall the system software.
Disconnect and connect the
connectors of the read
An error has occurred in the communication communication cable. Check the
E732- between the reader unit and the main controller. power supply of the reader unit (to
0001 An error has occurred in the communication see if initialization occurs at power-
between the reader unit and the main controller. on). Replace the reader controller
PCB. Reap the reader I/F PCB.
Replace the main controller PCB.
A fault has been detected in the I/F PCB. Replace the main controller PCB.
reader sync signal detection
mechanism.
An error has occurred in the
communication between the
reader unit and the main Disconnect and then connect the connector. Check the
E733- controller. power supply of the DC controller (to see if initialization
0000 An error has occurred in the occurs at time of start-up). Replace the DC controller
communication between the PCB. Replace the main controller PCB.
reader unit and the main
controller.
An error has occurred in the
communication between the Disconnect and then connect the connector. Check the
E733- reader unit and the main power supply of the DC controller (to see if initialization
0001 controller. occurs at time of start-up). Replace the DC controller
An attempt to communicate PCB. Replace the main controller PCB.
with the DC controller fails
An error has occurred in the
communication between the
Disconnect and then connect the connector. Check the
reader unit and the main
E733- power supply of the DC controller (to see if initialization
controller.
0010 occurs at time of start-up). Replace the DC controller
A fault has occurred in the
PCB. Replace the main controller PCB.
printer engine sync signal
detection mechanism.
An error exists in the LAN
E740- controller.
Replace the main controller PCB.
0002 An illegal MAC address has
been detected at start-up.
A fault exists in the
communication between the
main controller and the reader
controller. Disconnect and then connect the connectors of the
E743-
The reader controller has reader communications cable. Replace the reader
0000
detected an error in the controller PCB. Replace the main controller PCB.
communication between the
main controller and the reader
controller.
An error exists in the language
file/boot ROM.
E744- Update the version of the language file (Language), or
The version of the language file
0001 install the appropriate file.
on the HDD and that of
bootable do not match.
An error exists in the language
E744- file/boot ROM. Update the version of the language file (Language), or
0002 The language file on the HDD is install the appropriate file.
too large.
30
The home position is not ascent/ descent motor. Replace the fixing inlet sensor
detected when he sensor is ascent/descent motor driver PCB.
moved up/down (i.e., the
sensor has not gone on).
An HP detection error has
occurred in relation to the Disconnect and then connect J508, J552, and J553 of the
fixing inlet sensor (fixing DC controller PCB. Disconnect and then connect J4001
E840- wrap jam detection). and J4002 of the fixing inlet sensor ascent/descent motor
0001 The home position is not driver PCB; as necessary, replace the fixing inlet sensor
detected when the sensor ascent/ descent motor. Replace the fixing inlet sensor
is moved up/down (i.e., the ascent/descent motor driver PCB.
sensor has not gone off).
There is a fault in the
Remove paper lint form the surface of the double-feeding
double-feeding detection
sensor (reception). Remount the double-feeding sensor
unit.
(transmission, reception). Disconnect and then connect
E850- The double-feeding sensor
J509 and J550 of the DC controller PCB. Replace the
(reception) fails to attain an
double-feeding sensor (transmission, reception). Replace
ultrasonic signal of a
the double-feeding sensor PCB (transmission, reception).
specific level.