Loads for 2nd, 3rd, 4th and 5th Floor

Component Description Load (kPa)


Wood Furring System 0.12
Ceiling Plywood (12 mm) per thickness
0.72
(0.006)
Windows, Glass Frames, and
Sash 0.38
Frame Walls Exterior Stud Walls (50 x 100
@400 mm, 15 mm gypsum, 0.53
insulated loading
Plaster (0.24 per face) Both
Exterior Wall 0.48
face
19.6 kN/ thickness (150mm,
Masonry Unit full) 2.82
Floor Finish Cearmic Tiles 0.77

Slab Reinforced Concrete (Slab 3.54


depth 150 mm)

Beam 7.08
Reinforced Concrete (300 mm
by 300 mm)
h Floor
Load (kPa)
0.12
0.72
0.38
SYMBOLS
0.53
V
Kd
0.48
Kz
2.82 Kzt
0.77 Iw

3.54 G

h
7.08
qh

Cp

GCᵨᵢ

GCᵨ
NOTATIONS
Basic wind speed obtained from table 207-1, kph
Wind directionality factor in table 207-6
Velocity pressure coefficient evaluated at height z
Topographic factor as defined in section 207.7.2
Importance Factor

Gust effect factor for rigid buildings, also called “simplified dynamic response factor”
and is equivalent to Gf with R (resonant response factor) assumed as zero

Mean roof height of the building, tower or other structure, except that eave height
for a building shall be used for roof angle θ of less than or equal to 10°, m

Velocity pressure coefficient evaluated at height z = h, Kpa


External pressure coefficient to be used in the determination of wind loads for
buildings
Product of internal pressure coefficient and gust effect factor to be used in the
determination of wind loads for buildings

Product of external pressure coefficient and gust effect factor to be used in


determination of wind loads for buildings