Documente Academic
Documente Profesional
Documente Cultură
•
Ultrasonic Flowmeter/ monitoring
Monitor/Counter/Dosing Unit •
analysing
DUK
OOMeasuring range:
0.08 - 20 … 2.5 - 630 l/min
OO Accuracy: 0.7 % of reading + 0.7 % of full scale
OO Range span: 250
S5
OO pmax: 16 bar; tmax: 120 °C
OO Connection: G ½ … G 3, ½" … 3" NPT female
OO Material: brass or stainless steel 1.4408
OOAnalogue, frequency and switching outputs,
compact electronic with digital display,
dosing and counter electronic
www.kobold.com
1
Ultrasonic Flowmeter/Monitor/Counter/Dosing Unit Model DUK
Description Advantages
The new KOBOLD type DUK flow meters are used for the OO High range span of 1:250
measurement, monitoring, metering and dosing of low OO Small pressure loss
viscosity fluids.
OO High repeat accuracy ± 0.1 % of full scale
The devices work on the principle of the difference in running
OO Independent from density and temperature
times. This is based on the fact that ultrasonic waves in a
medium are influenced by the speed of flow. Areas of Application
Two sensors mounted opposite one another in the pipeline OO Machine building
function simultaneously as transmitter and receiver of
OO Automotive
ultrasound signals.
If there is no flow, then the running times of both signals are OO Robotic
identical. If the medium is flowing, then the running time of the OO Cooling
signal against the flow is longer than that with the flow. OO Hot water
The running time difference, which is determined by a
microprocessor, is proportional to the speed of flow. Technical Details
Sensor
Measuring principle: ultrasonic
L Range: see table
Medium: water with max. 1 % solid
T1 Viscosity: max. 5 mm²/s
Accuracy: 0.7 % of reading + 0.7 % of full scale
C Repeat accuracy: ±0.1 % of full scale
Vm
Mounting position: in all directions, fl ow in direction of
the arrow (horizontal: electronic on
top or below)
T2
In-/Outlet: 10 x DN
Electronic
Elektronik Media temperature: -20 ... +90 °C
-20 ... +120 °C (high temp. version)
The devices can be equipped with a switching output, Ambient temperature: -20 ... + 70 °C
a frequency output or an analogue output. In addition, a Response time t90: approx. 0.5...1 s at flow change
compact circuit can be selected that features a digital display, > 10 % FS
a switching output and an analogue output. (depending on electronic version)
The device series is rounded off by an optionally available Pressure: 0 …16 bar
dosing and meter circuit. The meter circuit indicates the Pressure loss: max. 150 mbar at full scale
momentary flow rate in the first line of the display and the Protection: IP 65
partial or total quantity in the second line. A dosing circuit
Wetted Parts
controls simple filling tasks and similarly measures flow rates,
total amounts and filling amounts. The analogue output and Sensor housing: brass or stainless steel 1.4408
two relay outputs can be used for further processing of the Sensors: PEEK
signals. Seal: NBR, other on request
high temp. version FPM
DUK-1xx5 0.16 - 40 ¾" approx. 1050 g approx. 1250 g approx. 1200 g approx. 2350 g approx. 2900 g
DUK-1xx6 0.25 - 63 1" approx. 1450 g approx. 1650 g approx. 1600 g approx. 2750 g approx. 3300 g
DUK-1xx8 0.6 - 150 1½" approx. 2350 g approx. 2550 g approx. 2500 g approx. 3650 g approx. 4200 g
DUK-1xx9 1 - 250 2" approx. 3800 g approx. 4000 g approx. 3950 g approx. 5100 g approx. 5650 g
DUK-1xxB 2.5 - 630 3" approx. 7100 g approx. 7300 g approx. 7250 g approx. 8400 g approx. 8950 g
1/09- 2015
Electrical Connection
DUK-...S300 DUK-...S30D
output 2 1 +Vs
N/O output 2 1 +Vs
output N/C
common
5
GND output
3 4 N/C GND output
3 4 N/O
2
Signal
3 out
1
GND Signal out
3 4 +VS
DUK-...C30* DUK-...C34*
GND GND
5
5
GND Switch out 1 GND switch out 1
3 4 3 4
Switching output
S300 = relay, M12-plug
S30D = aktiv 24 VDC, M12-plug
Frequency output
F300 = M12-plug, 500 Hz
F390 = M12-plug, 50…1000 Hz
G4H = G ½ female
Analogue output
G5H = G ¾ female L303 = M12-plug, 0-20 mA
G6H = G 1 female L343 = M12-plug, 4-20 mA L = from left
L443 = DIN-plug, 4-20 mA to right
DUK-11 = brass G8H = G 1½ female
Compact electronic
G9H = G 2 female R = from
DUK-12 = st. steel 1.4408 C30R = 2 x open collector, PNP right to
GBH = G 3 female
C30M = 2 x open collector, NPN left
DUK-21 = high temp. version C34P = 0(4)-20 mA, 1 x open collector, PNP T = from
brass N4H = ½" NPT female C34N = 0(4)-20 mA, 1 x open collector, NPN top to
N5H = ¾" NPT female ADI electronic bottom
DUK-22 = st. steel 1.4408
high temp. version N6H = 1" NPT female Display Power supply Output Contacts B = from
N8H = 1½" NPT bottom
female K = bar graph/ 0 = 100-230 VAC/DC 0 = without to top
2 = 2 change-
N9H = 2" NPT female digital 3 = 18-30 VAC, 4 = 0(4)-20 mA, over contacts
display 10-40 VDC 0-10 V
NBH = 3" NPT female
Counter electronic
E14R = LCD, 0(4)-20 mA, 2 x relays, 1 m cable
E34R = LCD, 0(4)-20 mA, 2 x relays, M12-plug
Dosing electronic
G14R = LCD, 0(4)-20 mA, 2 x relays, 1 m cable
G34R = LCD, 0(4)-20 mA, 2 x relays, M12-plug
Dimensions DUK-Sensor
Model G/NPT SW H H* L B
[mm] [mm] [mm] [mm] [mm]
* High Temp.-Version
1/09 - 2015
Dimensions
DUK-…S30x, DUK-…F3x0, DUK-…L3x3 DUK-…L443
11
8
M12x1
55.5
28
17.5
17.5
60
60
34
34
DUK-…C3xx DUK-…ExxR, DUK-…GxxR
Ø44.5 48 90
21.2
ca. 61
58.5
M12x1
7
60
34
S1 S2
PGM START
ENTER STOP
OBOLD
S1 S2
P ADI-1
1/09- 2015