Applicability of Caesar II for stress analysis of lines

having D/t ratio more than 100.

Sometimes while working you may have come across situations when the pipe diameter to thickness

ratio becomes more than 100. These normally happen for very large size low pressure systems. Due

to low design pressure (of the order of 1 bar to 3 bar) calculated thickness is less. As for example

consider a flare line of 42 inch (or 48 inches) NPS with 3 bar design pressure. The selected thickness

is STD wall thickness i.e, 9.525 mm. So Diameter to thickness ratio is more than 100. Normally

Caesar II is widely used for stress analysis of all piping systems. But when you use the software for

stress analysis of such stress systems you will find a warning message similar to as shown in Fig. 1.

This warning message is generated for all Bend and Intersections in the pipe.

So whether you will proceed for stress analysis ignoring such warning messages. ASME B 31.3 does
not provide any equation for calculating the SIF values for lines with D/t exceeding 100 (Also known
as thin walled pipes). This restriction on D/t comes from the B31.1 and B31.3 piping codes because
they do not have computations for stress intensification factors above this threshold, largely because
the testing that was done by Markl had this same limitation. CAESAR II will continue to use the
existing code formulations for SIF calculation when a D/t ratio is greater than 100, but no one knows
if these relations are still valid. That is the reason Caesar II displays such warning.
CAESAR II is a pipe flexibility analysis software package and as with all such packages, there are
limitations which should not be exceeded. It is always better to use some sort of FEA analysis for
analysing such systems and you will get accurate results. But considering the number of such stress
systems in any project (hardly one or two) purchasing costly FEA software may not get project
approval. So in such situation you may not have other options than to use Caesar II. So the analyst
can use Caesar II, but he needs to always bear the following points in mind:

 Failure of thin wall piping is dominated by buckling phenomenon and the validity of the
flexibility analysis assumptions decrease. CAESAR II and other such flexibility analysis
programs (CAEPIPE, AUTOPIPE etc.) do not compute buckling because it is a localized
effect caused by imperfections in manufacture, uneven corrosion, pitting, or other defects.
CAESAR II considers the pipe to be homogeneous in cross-section with an even wall
thickness everywhere. So the analyst is encouraged to consider buckling separately from
the CAESAR II analysis for such systems.
 Another problem with very thin-walled pipe is local deformation in the region of restraint.
When significant local deformation is likely at restraint locations, the load distribution will no
longer follow expectations as with homogeneous cross-sections and standard flexibility
analysis results should not be relied on. Normally it is a standard practice to use wear pads
in all support locations to reduce the possibility of local deformation at restraint points.
 It is better to use a lowered allowable stress than what is allowed by the piping code in use.
For example the analyst can reduce the allowable value by 75% of the code allowable.
 It is better to multiply the Caesar calculated SIF at intersections by 2.5-3.0 and input the
same manually at all three node points (Branch and header).