Sunteți pe pagina 1din 21

Dr.

Juliza Jamaludin
Faculty of Engineering and Built Environment

Revolutionizing Imaging: Real-


Time Optical Tomography Using
CCD Sensor
Tomography
Medical Types of
Application Tomography
Full Body Scan X-Ray, MRI,
NMR
Respiratory, PET Positron
digestive Emission
system, brain Tomography,
scanning radio isotopes
Mammography Ultrasound
Tomography
Process Control

• Petroleum refining systems


• Textile and fabric industries
• Oil and gas pipeline systems
• Geothermal wells
• Steam generation in boilers and burners
• Food and beverages industries
Invasive and Intrusive System

Liquid probe Optical fiber probe

Isokinetic sampling
probe
Requirement of Monitoring
System

Non-invasive and non-intrusive system


-Provide accurate measurement
-Remain the stability of process flow
Non- hazardous system
-No exposure of radiation
Tomography System

tomographic cross sections S1 and


S2 compared with the (not
tomographic) projected image P
Sensors are distributed around the periphery
of the analyzed system.
Tomography Analysis
• A tomographic imaging software
system with a mathematical
algorithm is designed to analyse
the:
Concentration
Velocity
Mass flow rate
Particle size distribution
Optical Tomography System (OPT)
• The Optical Tomography System is considered
as a hard-field sensor because
“ the sensing field is based on the measurement
of the light attenuation or absorption.”
Optical Tomography System (OPT)
The OPT system provides a good spatial
resolution, where it can capture a very
detailed image without making the pixels
visible.
Immunity to electrical noise or interference
OPT also provides a high-speed data capture
system and,
it is suitable for real-time monitoring system
applications.
Real-Time Optical Tomography
System (OPT) Using CCD Sensor

X-RAY : CCD in medical field

CCD OPT SYSTEM : CCD in


industrial field
Real-Time Optical Tomography
System (OPT) Using CCD Sensor

Transmitter :Low power laser diode system


650nm wavelength
Real-Time Optical Tomography
System (OPT) Using CCD Sensor
Object Top View 3 Dimensional Side view

Opaque

Translucent

Transparent

1. Analysis on the object concentration


Real-Time Optical Tomography
System (OPT) Using CCD Sensor

1. Analysis on the object concentration


Real-Time Optical Tomography
System (OPT) Using CCD Sensor

2. Analysis on the object size distribution


Real-Time Optical Tomography
System (OPT) Using CCD Sensor

2. Analysis on the object size distribution


Real-Time Optical Tomography
System (OPT) Using CCD Sensor

3. Analysis on the object velocity


Real-Time Optical Tomography
System (OPT) Using CCD Sensor

3. Analysis on the object velocity


CONCLUSION
 The experiments had proved that the CCD OPT
system is capable of detecting the existence of
different opacity of object in crystal-clear water
during the monitoring processes.
 This CCD OPT system is able to distinguish between
gas bubbles and solid objects.
 The CCD OPT system developed is a non-intrusive
and non-invasive system.
 Since no probes or sensors need to be fitted in the
liquid medium, this system offers more accurate data
due to the absence of any interference for the
pipeline monitoring processes.