SPLIT TYPE

Change for life

Owner's Manual
Original Instructions
Air Conditioners

Air-to-water Heat Pump Split Versati


Models:
GRS-CQ8.0Pd/NaE-K GRS-CQ10Pd/NaE-K
GRS-CQ12Pd/NaE-K GRS-CQ14Pd/NaE-K
GRS-CQ16Pd/NaE-K GRS-CQ12Pd/NaE-M
GRS-CQ14Pd/NaE-M GRS-CQ16Pd/NaE-M

Thank you for choosing GREE air conditioners. Please read this
Owner’s Manual carefully before operation and retain it for future
reference.
If you have lost the Owner's Manual,please contact the local agent
or visit www.gree.com or send an email to global@gree.com.cn for
the electronic version.
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI
To Users
Thank you for selecting Gree’s product. Please read this instruction manual carefully before installing and using
the product, so as to master and correctly use the product. In order to guide you to correctly install and use our
product and achieve expected operating effect, we hereby instruct as below:
(1) This equipment should be installed, operated or maintained by the qualified servicemen who have had
specific training. During operation, all safety issues covered in the labels, User’s Manual and other
literature should be followed strictly. This appliance can be used by children aged from 8 years and above
and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning used of this appliance in a safety way
and understand the hazards involved. Children shall not play with the appliances. Cleaning and user
maintenance shall not be made by children without supervision.
(2) This product has gone through strict inspection and operational test before leaving the factory. In order to
avoid damage due to improper disassembly and inspection, which may impact the normal operation of unit,
please do not disassemble the unit by yourself. You can contact with the special maintenance center of our
company if necessary.
(3) For personal injury or property loss and damage caused by improper operation such as improper
installation and debugging, unnecessary maintenance, violation of related national laws and rules and
industrial standard, and violation of this instruction manual, etc., we will bear no liability.
(4) When the product is faulted and cannot be operated, please contact with our maintenance center as soon
as possible by providing the following information.
• Contents of nameplate of product (model, cooling/heating capacity, product No., ex-factory date).
• Malfunction status (specify the situations before and after the error occurs).
(5) All the illustrations and information in the instruction manual are only for reference. In order to make the
product better, we will continuously conduct improvement and innovation. We have the right to make
necessary revision to the product from time to time due to the reason of sales or production, and reserve
the right to revise the contents without further notice.
(6) The final right to interpret for this instruction manual belongs to Gree Electric Appliances Inc. of Zhuhai.
Contents

Safety Notices (Please be sure to abide ).................................................................... 1


1. Diagram of the Operating Principle.......................................................................... 7
2. Operating Principle of the Unit.................................................................................. 8
3. Nomenclature........................................................................................................... 10
4. Installation Example .............................................................................................. 11
5. Main Components ................................................................................................... 14
5.1 Indoor unit........................................................................................................................14
5.2 Outdoor unit ...................................................................................................................16
6. Installation Guideline of Outdoor Unit.................................................................... 19
6.1 Instruction to installation..................................................................................................19
6.2 Installation of outdoor unit................................................................................................19
7. Installation of Indoor Unit........................................................................................ 21
7.1 Select installation location of indoor unit .........................................................................21
7.2 Install process of indoor unit............................................................................................22
7.3 Outline dimension of indoor unit ....................................................................................24
7.4 Space requirements for installation..................................................................................24
7.5 Precautions on installation of indoor unit.........................................................................25
7.6 Water volume and pump capacity (with pump)................................................................25
7.7 Water volume and expansion vessel pressure................................................................25
7.8 Selection of expansion vessel..........................................................................................26
8. Connection of Pipeline ............................................................................................ 27
8.1 Connection of outlet pipe for indoor & outdoor unit ........................................................27
8.2 Installation of protective layer on connection pipe ..........................................................27
9. Remote Air Temperature Sensor............................................................................. 29
10. Thermostat.............................................................................................................. 30
11. 2-Way Valve............................................................................................................. 31
12. 3-Way Valve............................................................................................................. 32
13. Other Auxiliary Heat Sources .............................................................................. 32
14. Gate-controller........................................................................................................ 32
15. Charging and Discharging of Refrigerant............................................................ 33
16. Refrigerant Collecting............................................................................................ 34
17. Handling of the Unit............................................................................................... 35
18. Installation of Insulated Water Tank .................................................................... 36
18.1 Installation measure.......................................................................................................36
18.2 Outline dimension and parameter of water tank............................................................37
18.3 Connection of waterway system....................................................................................38
18.4 Electric wiring work .......................................................................................................39
19. Wring Diagram........................................................................................................ 41
19.1 Control Board.................................................................................................................41
19.2 Electric Wiring................................................................................................................49
20. Commissioning...................................................................................................... 53
20.1 Check before startup......................................................................................................53
20.2 Test run..........................................................................................................................54
21. Daily Operation and Maintenance ........................................................................ 55
SPLIT TYPE
Air-to-water Heat Pump Split Versati

Safety Notices (Please be sure to abide )

WARNING: If not abide strictly, it may cause severe damage to the unit or the
people.
NOTE: If not abide strictly, it may cause slight or medium damage to the unit or the
people.
This sign indicates that the operation must be prohibited. Improper operation may
cause severe damage or death to people
This sign indicates that the items must be observed. Improper operation may
cause damage to people or property.

NOTE
After receipt of the unit, check it for appearance, unit model compared with your desire
and attachments.
Design and installation work of the unit must be performed by authorized personnel
according to applicable laws and regulations and this Instruction.
After installation work, the unit cannot be energized unless there is not any problem in
check.
Ensure periodical clean and maintenance of the unit after normal operation of the unit
for longer life and reliable operation.
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
The appliance shall be installed in accordance with national wiring regulations.
This product is a kind of comfort air conditioning, and is not allowed to be installed
where there are corrosive, explosive and inflammable substances or smog; otherwise
it would lead to operation failure, shortened service life, five hazard or even severe
injuries. Special air conditions are required for where mentioned above.

Correct Disposure
This marking indicates that this product should not be
disposed with other household wastes throughout the EU.To
prevent possible harm to the environment or human health from
uncontrolled waste disposal,recycle it responsibly to promote the
sustainable reuse of material resources. To retuern your used
device,please use the return and collection systems or contact
the retailer where the product was purchased. They can take this
product for environmental safe recycling.
R410A(R32/125:50/50):2087.5

1
Air-to-water Heat Pump Split Versati SPLIT TYPE

WARNING
Once abnormality Don't operate the unit with Before
likeburning smell occurs, wet hand. installation,please see
please cut off the power if the voltage of local
supply immediately and place accords with
then contact with service that on nameplate
center. of unit and capacity
of power supply,
power cord or socket
is suitable for input
power of this unit.

Otherwise, it may cause


electric shock.
If the abnormality still exists,
the unit may be damaged
and electric shock or fire
may result.
Be sure to pull out the Never damage the
Special circuit must be
power plug and drain the electric wire or use
adopted for power supply
indoor unit and water tank the one which is not
to prevent fire.
when unit is not in use for a specified.
long time.

Do not use octopus


multipurpose plug or mobile Otherwise, the accumulated Otherwise, it may
terminal board for wire dust may cause cause overheating or
connection. overheating,fire or freeze of fire.
water tank or coaxial heater
exchanger in winter.

2
SPLIT TYPE
Air-to-water Heat Pump Split Versati

Before cleaning please cut The power supply must User can not change
off the power supply. adopt special circuit with power cord socket
leakage switch and enough without prior consent.
capacity. Wiring working
must be done by
professionals. Ensure
good earthing and
don't change earthing
mode of unit.

Otherwise, it may cause


electric shock or damage.
Earthing: the unit must Never insert any foreign Don't attempt to repair
be earthed reliably ! The matter into outdoor unit to the unit by yourself.
earthing wire should avoid damage . And never
connect with special device insert your hands into the
of buildings. air outlet of outdoor unit.

Improper repair may


cause electric shock
or fire, so you should
If not, please ask the contact the service
qualified personnel to center to repair.
install.
Furthermore, don't connect
earth wire to gas pipe,
water pipe, drainage pipe or
any other improper places
which professional does not
recognize.

3
Air-to-water Heat Pump Split Versati SPLIT TYPE

Don't step on the top of the Never block the air inlet and Keep pressurized
unit or place anything on it. outlet of unit. spray, gas holder and
so on away from the
unit above 1m .

There is the danger of fall of


things or people. It may reduce efficiency or
cause stop of the unit and
even fire. It may cause fire or
explosion.
Please note whether the Unit should be installed When there is not
installation stand is firm at the place with good water in water tank,
enough or not. ventilation to save energy. never power the unit
on to run.

If damaged, it may cause


fall of the unit and injury of
people.

4
SPLIT TYPE
Air-to-water Heat Pump Split Versati

NOTE
Before installation, please check if the adopted power is accordance with that listed on
nameplate, and check the safety of power.
An all-pole disconnection switch having a contact separation of at least 3mm in all
poles should be connected in fixed wiring.
Before using, please check and confirm if wires and water pipes are connected
correctly to avoid water leakage, electric shock or fire etc.
Don’t operate the unit with wet hand, and don’t allow children to operate the unit.
The On/off in the instruction is for the operation to on and off button of PCB for users;
cut off power means to stop supplying power to the unit.
Don’t directly expose the unit under the corrosive ambient with water or dampness.
Don’t operate the unit without water in water tank .The air outlet/inlet of unit cannot be
blocked by other objects.
The water in unit and pipeline should be discharged if the unit is not in use, to prevent
the water tank, pipe line and water pump from frost-cracking.
Never press the button with sharp objects to protect manual controller. Never use
other wires instead of special communication line of the unit to protect control elements.
Never clean the manual controller with benzene, thinner or chemical cloth to avoid
fading of surface and failure of elements. Clean the unit with the cloth soaked in neutral
eradicator. Slightly clean the display screen and connecting parts to avoid fading.
The power cord must be separated with the communication line.

5
Air-to-water Heat Pump Split Versati SPLIT TYPE

maximum and minimum water operating temperatures.


Maximum
Minimum water operating
Item water operating
temperatures temperatures
Cooling 7°C 25°C
Heating 25°C 55°C
Water heating 40°C 80°C
maximum and minimum water operating pressures.
Minimum water operating Maximum water
Item pressures operating pressures
 Cooling
Heating 0.05MPa 0.25MPa
Water heating
maximum and minimum entering water pressures.
Minimum entering water Maximum entering
Item pressures water pressures
 Cooling
 Heating 0.05MPa 0.25MPa
Water heating
The range of external static pressures at which the appliance was tested (add-on
heat pumps, and appliances with supplementary heaters, only); If the supply cord
is damaged, it must be replaced by the manufacturer, its service agent or similarly
qualified persons in order to avoid a hazard.
The appliance is intended to be permanently connected to the water mains and not
connected by a hose-set.
If there is any question, please contact with local dealer, authorized service center,
agencies or our company directly.

6
SPLIT TYPE
Air-to-water Heat Pump Split Versati

1. Diagram of the Operating Principle

Outdoor Unit Indoor Unit Field Supplied


7
23 24 25 28 33 42
8
27 29 30
43

6 26 47
9
E
5 4 10 44 46

S D
3
45
C
40 39
11
2 12 18 21
37
49 36
34
38
48 41

16 1 20
13 19 35
14 22

17 50 31
32

15

No. Name No. Name No. Name

Liquid Temperature
1 Compressor 18 35 Water Tank
Sensor of the PHE
Discharge Temperature Gas Temperature Sensor of the Leaving Water Temperature
2 19 36
Sensor PHE Sensor of the Solar System
Flow Switch for the Solar
3 High Pressure Switch 20 Plate-type Exchanger 37
System
Leaving Water Temperature Water Pump for the Solar
4 Pressure Sensor 21 38
of the PHE System
Entering Water Temperature
5 4-way Valve 22 39 Solar Panel
of the PHE

6 Finned Exchanger 23 Automatic Exhaust Valve 40 Solar Panel Temperature Sensor

Environment Entering Water Temperature


7 24 Electric Heater 41
Temperature Sensor for the Solar System
Defrosting Temperature
8 25 Safety Valve 42 Water Knockout Vessel
Sensor

9 Filter 26 Expansion Tank 43 Electric 2-way Valve 1

Electrostatic Expansion Leaving Water Temperature


10 27 44 Floor Radiator
Valve of the Electric Heate

11 Filter 28 Water Pump 45 Water Collector

12 Liquid Valve 29 Flow Switch 46 FCU

Leaving Water Pipe Pressure Differential Bypass


13 Gas Valve 30 47
Connector Valve
Entering Water Pipe Water Tank Temperature
14 Filter 31 48
Connector Sensor 2

15 Vapor-liquid Separator 32 Water Filter 49 Liquid Valve Connector

Suction Temperature
16 33 Electric 3-way Valve 2 50 Gas Valve Connector
Sensor
Water Tank Temperature
17 Pressure Sensor 34
Sensor 1

7
Air-to-water Heat Pump Split Versati SPLIT TYPE

2. Operating Principle of the Unit


DC Inverter Air to Water Heat Pump is composed of outdoor unit, indoor unit and internal-fan coil water tank.
Operation functions:
(1) Cooling;
(2) Heating;
(3) Water heating;
(4) Cooling +water heating;
(5) Heating+ water heating;
(6) Emergency mode;
(7) Quick water heating;
(8) Holiday mode;
(9) Forced Operation Mode;
(10) Silent mode;
(11) Disinfection mode;
(12) Weather-dependent Operation;
(13) Floor debugging;
(14) Air removal of the water system;
(15) Solar water heater;
(16) Backup heat source
Cooling: in cooling mode, the refrigerant is condensed in the outdoor unit and evaporated in the indoor unit. Via
the heat exchange with water in the indoor unit, the temperature of water decreases and it releases heat while the
refrigerant absorbs heat and evaporates. With the help of wired controller, the outflow temperature can meet the
user’s requirement. Through the control of valve, the low-temperature water in the system is connected with indoor
fan coil and underground pipe, and exchanges heat with the indoor air so that the indoor temperature decreases to
the required range.
Heating: in heating mode, the refrigerant evaporates in the outdoor unit and is condensed in the indoor unit.
Via the heat exchange with water in the indoor unit, the water absorbs heat and its temperature increases while the
refrigerant releases heat and is condensed. With the help of wired controller, the outflow temperature can meet the
user’s requirement. Through the control of valve, the high-temperature water in the system is connected with indoor
fan coil and underground pipe, and exchanges heat with the indoor air so that the indoor temperature increases to
the required range.
Water heating: in water heating mode: the refrigerant evaporates in the outdoor unit and is condensed in
the indoor unit. Via the heat exchange with water in the indoor unit, the water absorbs heat and its temperature
increase while the refrigerant releases heat and is condensed. With the help of wired controller, the outflow
temperature can meet the user’s requirement. Through the control of valve, the high-temperature water in the
system is connected with the coil pipe of bearing water tank, and exchanges heat with the water in the water tank
so that the temperature of water tank increases to the required range.
Cooling + water heating: when cooling mode exists together with the water heating mode, the user can set the
priority of these two modes based on the needs. The default priority is heat pump. That is under the default setting,
if cooling mode exists together with the water heating mode, the heat pump gives priority to cooling. In that case,
water heating can only realized with e-heater of the water tank. Inversely, the heat pump gives priority to water
heating and switches to cooling after finishing water heating.
Heating+ water heating: when heating mode exists together with the water heating mode, the user can set the
priority of these two modes based on the needs. The default priority is heat pump. That is under the default setting,
if heating mode exists together with the water heating mode, the heat pump gives priority to heating. In that case,
water heating can only realized with e-heater of the water tank. Inversely, the heat pump gives priority to water
heating and switches to heating after finishing water heating.

8
SPLIT TYPE
Air-to-water Heat Pump Split Versati

Emergency mode: this mode is only available for heating and water heating. When the outdoor unit stops due
to malfunction, enter the corresponding emergency mode; as to heating mode, after entering the emergency mode,
heating can only be realized through e-heater of the indoor unit. When the setting outflow temperature or indoor
temperature is reached, the e-heater of indoor unit will stop running; as to water heating mode, the e-heater of
indoor unit stops while the e-heater of water tank runs. When the setting temperature or water tank is reached, the
e-heater will stop running.
Quick water heating: in quick water heating mode, the unit runs according to the water heating control of heat
pump and the e-heater of water tank runs at the same time.
Forced operation mode: this mode is only used for refrigerant recovery and debugging for the unit.
Holiday mode: this mode is only available for heating mode. This mode is set to keep indoor temperature or
leaving water temperature in a certain range, so as to prevent water system of the unit from freezing or protect
certain indoor articles from freezing damage. When the outdoor unit stops due to malfunction, the two e-heaters of
the unit will run.
Disinfection mode: in this mode, the water heating system can be disinfected. When starting up the disinfection
function and setting corresponding time to meet the requirement of disinfection mode, the function will start. After
the setting temperature is reached, this mode will terminate.
Weather-dependent operation: this mode is only available for space heating or space cooling. In Weather-
dependent mode, the setting value (remote room air temperature or leaving water temperature) is detected and
controlled automatically when the outdoor air temperature is changed.
Quiet mode: silent mode is available in cooling, heating and water heating mode. In silent mode, the outdoor
unit will reduce the running noise via automatic control.
Floor commissioning: this function is intended to preheat the floor periodically for the initial use.
Air removal of the water system: this function is intended to replenish water and remove air in the water
system to make the equipment run at the stabilized water pressure.
Solar water heater: when the condition for starting the solar water heater is satisfied, the solar heater will start
to heat the circulation water. Then the heated water will go to the water tank and exchange heat with water in it. At
any condition, the solar water heater will be given priority for startup so as for energy conservation.
Backup heat source: when the outdoor temperature is lower than the set point for starting the backup heat
source and the unit is under the error condition and the compressor has stopped for three minutes, then the backup
heat source will start to supply heat or hot water to the room.

9
Air-to-water Heat Pump Split Versati SPLIT TYPE

3. Nomenclature
G RS - C Q 16 Pd / Na E - M (O)

1 2 3 4 5 6 7 8 9 10

NO. Description Options


1 GREE G-GREE Air to water heat pump

2 Heat Pump Water Heater RS

3 Heating Mode S= Static; C=Circulating

4 Function Q=Multi-function; Omit=Single-function

5 Nominal Heating Capacity 6.0=6.0kW; 8.0=8.0kW;10=10kW; 12=12kW; 14=14kW; 16=16kW

6 Compressor Style Pd=DC Inverter; Omit=On/Off

7 Refrigerant Na=R410A

8 Design Serial Number B,C,D,E......

9 Power Supply K=220-240V,~,50Hz;M=380-415V,3N~,50Hz;H=380V,3N~,60Hz

10 Indoor and Outdoor Unit Code I=Indoor unit; O=Outdoor unit

Model Line-Up
Capacity
Model Name Power supply
1
Heating ,kW Cooling2,kW

GRS-CQ8.0Pd/NaE-K 8 7.8

GRS-CQ10Pd/NaE-K 10 8.2

GRS-CQ12Pd/NaE-K 12 12.5 220-240VAC 50Hz

GRS-CQ14Pd/NaE-K 14 13.5

GRS-CQ16Pd/NaE-K 15.5 14.5

GRS-CQ12Pd/NaE-M 12 13.5

GRS-CQ14Pd/NaE-M 14 14.5 380-415VAC 3Ph 50Hz

GRS-CQ16Pd/NaE-M 15.5 15
Notes
(a) 1Capacities and power inputs are based on the following conditions:
Indoor Water Temperature 30°C/35°C, Outdoor Air Temperature 7°C DB/6°C WB;
(b) 2Capacities and power inputs are based on the following conditions:
Indoor Water Temperature 23°C/18°C, Outdoor Air Temperature 35°C DB/24°C WB.
Operation Range
Mode Heat Source Side Temperature (°C) User Side Temperature (°C)

Heating -20~35 25~55

Cooling 10~48 7~25

Water Heating -20~45 40~80

10
SPLIT TYPE
Air-to-water Heat Pump Split Versati

4. Installation Example
CASE 1: Connecting Under floor Coil and Fan Coil Unit

Outdoor Indoor

Notes
(a) The two-way valve is very important to prevent dew condensation on the floor and FCU while cooling mode;
(b) Type of thermostat and specification should be complied with installation of this manual;
(c) The bypass valve must be installed to secure enough water flow rate, and should be installed at the
collector.
(d) When the FCU and the underfloor coil are used at the same time, performance of the underfloor coil is
satisfied firstly. When performance of the FCU is required, then “Floor config” should be set to “Without”.

11
Air-to-water Heat Pump Split Versati SPLIT TYPE

CASE 2: Connecting Under floor Coil, Fan Coil Unit and Water Tank

Outdoor Indoor

Notes
(a) The two-way valve is very important to prevent dew condensation on the floor and FCU while cooling mode
(b) In this case, three-way valve should be installed and should be complied with installation of this manual;
(c) When the FCU and the underfloor coil are used at the same time, performance of the underfloor coil is
satisfied firstly. When performance of the FCU is required, then “Floor config” should be set to “Without”.
(d) Anitary water tank should be equipped with internal electric heater to secure enough heat energy in the
very cold days.

12
SPLIT TYPE
Air-to-water Heat Pump Split Versati

CASE 3 : Connecting Under floor Coil, Fan Coil Unit , Water Tank and Solar System

Outdoor Indoor

Notes
(a) The two-way valve is very important to prevent dew condensation on the floor and FCU while cooling mode
(b) In this case, three-way valve should be installed and should be complied with installation of this manual;
(c) Anitary water tank should be equipped with internal electric heater to secure enough heat energy in the
very cold days.
(d) When the FCU and the underfloor coil are used at the same time, performance of the underfloor coil is
satisfied firstly. When performance of the FCU is required, then “Floor config” should be set to “Without”.
(e) For the solar heating system, only the control port is available and relative accessories are absent.

13
Air-to-water Heat Pump Split Versati SPLIT TYPE

5. Main Components
5.1 Indoor unit
(1) GRS-CQ8.0Pd/NaE-K(I),GRS-CQ10Pd/NaE-K(I)

External

Internal

14
SPLIT TYPE
Air-to-water Heat Pump Split Versati

(2) GRS-CQ12Pd/NaE-K(I), GRS-CQ14Pd/NaE-K(I), GRS-CQ16Pd/NaE-K(I), GRS-CQ12Pd/NaE-M(I)GRS-


CQ14Pd/NaE-M(I), GRS-CQ16Pd/NaE-M(I)

External

Internal

15
Air-to-water Heat Pump Split Versati SPLIT TYPE

5.2 Outdoor unit


(1) GRS-CQ8.0Pd/NaE-K(O),GRS-CQ10Pd/NaE-K(O)

External

Internal

16
SPLIT TYPE
Air-to-water Heat Pump Split Versati

(2) GRS-CQ12Pd/NaE-K(O), GRS-CQ14Pd/NaE-K(O), GRS-CQ16Pd/NaE-K(O)

External

Internal

17
Air-to-water Heat Pump Split Versati SPLIT TYPE

(3) GRS-CQ12Pd/NaE-M(O),GRS-CQ14Pd/NaE-M(O), GRS-CQ16Pd/NaE-M(O)

External

Internal

18
SPLIT TYPE
Air-to-water Heat Pump Split Versati

6. Installation Guideline of Outdoor Unit


6.1 Instruction to installation
(1) Installation of the unit must be in accordance with national and local safety codes.
(2) Installation quality will directly affect the normal use of the air conditioner unit. The user is prohibited from
installation. Please contact your dealer after buying this machine. Professional installation workers will
provide installation and test services according to installation manual.
(3) Do not connect to power until all installation work is completed.

6.2 Installation of outdoor unit


6.2.1 Select installation location of outdoor unit
(1) Outdoor unit must be installed on a firm and solid support.
(2) Outdoor unit shall be installed close to the indoor unit, hence to minimize the length and bends of cooling
pipe.
(3) Avoid placing the outdoor unit under window or between two constructions, hence to prevent normal
operating noise from entering the room.
(4) Air flow at inlet and outlet shall not be blocked.
(5) Install at a well-ventilated place, so that the machine can absorb and discharge sufficient air.
(6) Do not install at a place where flammable or explosive goods exist or a place subject to severe dust, salty
fog and polluted air.
6.2.2 Outline dimension of outdoor unit
(1) GRS-CQ8.0Pd/NaE-K(O),GRS-CQ10Pd/NaE-K(O)
788

427

395

650
980

19
Air-to-water Heat Pump Split Versati SPLIT TYPE

(2) GRS-CQ12Pd/NaE-K(O),GRS-CQ14Pd/NaE-K(O),GRS-CQ16Pd/NaE-K(O),GRS-CQ12Pd/NaE-
M(O),GRS-CQ14Pd/NaE-M(O),GRS-CQ16Pd/NaE-M(O)

1326

1345
900
572
340

412
378

Description:
Unit: inch
No. Name Remarks

1 Liquid-side Service Valve 3/8 GRS-CQ8.0/10Pd/NaE-K, GRS-CQ12/14/16 Pd/NaE-K, GRS-CQ12/14/16 Pd/NaE-M

2 Gas-side Service Valve 5/8 GRS-CQ8.0/10Pd/NaE-K, GRS-CQ12/14/16 Pd/NaE-K, GRS-CQ12/14/16 Pd/NaE-M

3 Handle Used to cover or uncover the front casew

4 Air discharge Grill /

20
SPLIT TYPE
Air-to-water Heat Pump Split Versati

6.2.3 Space requirements for installation

>1000
>500

>2000
>500 >500

>500
>2000

6.2.4 Precautions on installation of outdoor unit


(1) When moving outdoor unit, it is necessary to adopt 2 pieces of long enough rope to hand the unit from 4
directions. Included angle between the rope when hanging and moving muwst be 40 ℃ below to prevent
center of the unit from moving.
(2) Adopt M12 bolts components to tighten feet and under frame when installing.
(3) Outdoor unit should be installed on concrete base that is 10cm height.
(4) Requirements on installation space dimension of unit’s bodies are shown in following drawing.
(5) Outdoor unit must be lifted by using designated lifting hole. Take care to protect the unit during lift. To avoid
rusting, do not knock the metal parts.

7. Installation of Indoor Unit


7.1 Select installation location of indoor unit
(1) Avoid direct sunshine.
(2) Ensure the hanger rod, ceiling and building structure have sufficient strength to support the weight of air
conditioner unit.
(3) Drainage pipe is easy to connect out.
(4) Indoor and outdoor connection pipes are easy to go outdoors.
(5) Do not install at a place where inflammable or explosive goods exist or inflammable or explosive gas might
leak.
(6) Do not install at a place subject to corrosive gas, severe dust, salty fog, smoke or heavy moisture.

21
Air-to-water Heat Pump Split Versati SPLIT TYPE

7.2 Install process of indoor unit


Step1:Drilling hole on the wall in the following draw.
500
463

Expansion bolt hole

900
825
Unit outline

Step2:Releasing screws, detach front cover from the indoor unit.

22
SPLIT TYPE
Air-to-water Heat Pump Split Versati

Step3: Attaching indoor unit to the wall make use of accessory expansion bolt.

Expansion bolt

Wall

NOTENote
• While lifting the indoor unit, at least two persons should be joined. Weight of the indoor unit is more than 50kg.
• The indoor unit must be installed vertically to the ground and fastened securely.
• Before commissioning, the dust-proof cap of the automatic relief valve must be loosened, other than entirely being
removed away, and it can be tightened in case that it leaks.

23
Air-to-water Heat Pump Split Versati SPLIT TYPE

7.3 Outline dimension of indoor unit

900
981
324
500

Description:
Unit: inch
No. Name Remarks

1 Leaving Water Pipe 1″Male BSP

2 Returning Water Pipe 1″Male BSP

3 Gas-side Pipe 5/8 GRS-CQ8.0/10Pd/NaE-K, GRS-CQ12/14/16Pd/NaE-K, GRS-CQ12/14/16Pd/NaE-M

4 Liquid-side Pipe 3/8 GRS-CQ8.0/10Pd/NaE-K, GRS-CQ12/14/16Pd/NaE-K, GRS-CQ12/14/16Pd/NaE-M

7.4 Space requirements for installation

250

200 800
1300

Service Space

24
SPLIT TYPE
Air-to-water Heat Pump Split Versati

7.5 Precautions on installation of indoor unit


(1) Indoor unit shall be vertically mounted on the wall of the room with expansion bolt.
(2) Keep the indoor unit away from heat sources like heat sink and so on in the room as much as possible.
(3) Keep the indoor unit as close as possible to outdoor unit. Level distance between connection pipes cannot
exceed 30m (8.0~16kW) and vertical distance cannot exceed 15m (8.0~16kW).

7.6 Water volume and pump capacity (with pump)

Note
During operation, the water pump will adjust its output based on the actual load.

7.7 Water volume and expansion vessel pressure

2.5
Pre-pressure in expension vessel(Bar)

2.0

1.5

1.0

0.5

0.0
0 50 100 150 200 250 300 350 400
Maximum total water volume(liter)
Notes
(a) The expansion vessel is 10 liter and 1bar pre-pressurized;
(b) Total water volume of 280 liter is default; if total water is changed because of installation condition, the pre-
pressure should be adjusted to secure proper operation. If the indoor unit is located at the highest position,
adjustment is not required;
(c) Minimum total water volume is 20 liter;
(d) To adjust pre-pressure, use nitrogen gas by certificated installer.

25
Air-to-water Heat Pump Split Versati SPLIT TYPE

7.8 Selection of expansion vessel


Formula:

V--- Volume of expansion vessel


C--- Total water volume
P1--- Pre-set pressure of expansion vessel
P2-- The highest pressure during running of the system (that is the action pressure of safety valve.)
e---The expansion factor of water (the difference between the expansion factor of the original water temperature
and that of highest water temperature.)

Water expansion factor in different temperature

Temperature(℃) Expansion factor e

0 0.00013

4 0

10 0.00027

20 0.00177

30 0.00435

40 0.00782

45 0.0099

50 0.0121

55 0.0145

60 0.0171

65 0.0198

70 0.0227

75 0.0258

80 0.029

85 0.0324

90 0.0359

95 0.0396

100 0.0434

26
SPLIT TYPE
Air-to-water Heat Pump Split Versati

8. Connection of Pipeline
8.1 Connection of outlet pipe for indoor & outdoor unit
(1) Align the expansion end of copper pipe with the center of threaded joint. Tighten the flaring nuts with your
hands.
(2) Tighten the flaring nuts with torque wrench until you hear a “click”.
(3) Bend of fitting pipe shall not be too low; otherwise the fitting pipe might crack. Please use pipe bender when
bending the fitting pipe.
(4) When connecting outdoor and indoor unit, never pull the big and small joint of indoor unit with force, so as
to prevent the tubes of indoor unit from cracking and causing leakage.
(5) Connecting pipe shall be supported by a rack without transmitting its weight to other units.

8.2 Installation of protective layer on connection pipe


(1) To avoid condensate dew or water leakage on connecting pipe, the air pipe and liquid pipe must be
wrapped with heat preservation material and adhesive pipe for insulation from the air.
(2) The joints on indoor unit and outdoor unit must be wrapped with heat preservation materials and have no
clearance against the wall surface of indoor unit and outdoor unit.
(3) Wrap the pipe with tapes.
• Use the adhesive tape to wrap the connecting pipe and cable into one bundle. To prevent condensate
water from overflowing out of the drainpipe, the drainpipe shall be separated from connecting pipe and
cable.
• Wrap the heat preservation tape so that each ring of tape shall press half of the previous ring.

• Fix the wrapped pipe onto the wall with pipe clamp.

• Do not wrap the protective tape too tightly, as this will decrease the heat insulation performance.

• After completing the protection work and wrapping the pipe properly, close the wall holes with sealing
materials.

No clearance

27
Air-to-water Heat Pump Split Versati SPLIT TYPE

Indoor unit
Outdoor unit

Indoor unit

A
A
Outdoor unit

B B

Outdoor unit

Indoor unit
Oil trap

Pipe size
Length B Elevation A Additional
Model (Diameter:Φ)
refrigerant
gas Liquid Standard Max. Standard Max.

GRS-CQ8.0Pd/NaE-K 5/8" 3/8" 5m 30m 0m 15m 50g/m

GRS-CQ10Pd/NaE-K 5/8" 3/8" 5m 30m 0m 15m 50g/m

GRS-CQ12Pd/NaE-K 5/8" 3/8" 5m 30m 0m 15m 50g/m

GRS-CQ14Pd/NaE-K 5/8" 3/8" 5m 30m 0m 15m 50g/m

GRS-CQ16Pd/NaE-K 5/8" 3/8" 5m 30m 0m 15m 50g/m

GRS-CQ12Pd/NaE-M 5/8" 3/8" 5m 30m 0m 15m 50g/m

GRS-CQ14Pd/NaE-M 5/8" 3/8" 5m 30m 0m 15m 50g/m

GRS-CQ16Pd/NaE-M 5/8" 3/8" 5m 30m 0m 15m 50g/m


Notes
(a) No additional charge of the refrigerant is need when the pipe length is less than 10m, if the pipe length is
longer than 10m, additional charge of the refrigerant is needed according to the table.
(b) Example: If 14kW model is installed at a distance of 25m, (25-10)x50=750g refrigerant should be added.
Rated capacity is based on standard pipe length and maximum allowable length is based on the product
reliability in the operation. Oil trap should be installed every 5-7 meters when the location of outdoor unit is
higher than indoor unit.

28
SPLIT TYPE
Air-to-water Heat Pump Split Versati

9. Remote Air Temperature Sensor

Front side Back side

CN15
Remote Air Environment
Temp sensor

PCB CN1 15K RT6

AP

2
Electric box

Notes
(a) Distance between the indoor unit and the remote air temperature sensor should be less than 15m due to
length of the connection cable of remote air temperature sensor;
(b) Height from floor is approximately 1.5m;
(c) Remote air temperature sensor cannot be located where the area may be hidden when door is open;
(d) Remote air temperature sensor cannot be located where external thermal influence may be applied;
(e) Remote air temperature sensor should be installed where space heating is mainly applied;
(f) After the remote air temperature sensor is installed, it should be set to “With” through the wired controller so
as to set the remote air temperature to the control point.

29
Air-to-water Heat Pump Split Versati SPLIT TYPE

10. Thermostat
Installation of the thermostat is very similar to that of the remote air temperature sensor.
XT5 XT5 XT6

17 18 19 20 21 22 23 24 33 34

L(220V AC)
24V GND

24V AC
COOL

COOL
HEAT

HEAT
OFF

OFF

N
Thermostat Thermostat

How to Wire Thermostat


(1) Uncover the front cover of indoor unit and open the control box;
(2) Identify the power specification of the thermostat, if it is 230V, find terminal block XT5 as NO.22~24 and
block XT6 as NO.33~34;Otherwise, if it is 24V, find terminal block XT5 as NO.17~21;
(3) If it is the heating/cooling thermostat, please connect wire as per the figure above.
Installation Examples

10~30℃ , By means of a large Directly onto the wall or wall-box (mounting screws
Setpoint range Mounting
setpoint dial supplied)
Up to 9 screw-in terminals per unit, capable of
Supply voltage 230V, 50/60Hz Wiring
accepting wires up to 1.5mm2.
Thermostat switch S.P. D.T. Enclosure Plastic 2-piece housing
Typical differential 1℃ (heating
Dimensions 85*130*40mm(W*H*D)
Performance & cooling) at 20 at 50% load with
Protection class IP30
anticipator connected
4(2)A, 230V, Typical loads
are fans, zone valves, relays,
compressors. Compressors of Environmental
Electric ratings Operating temperature range 0 to 40℃ . S
greater than 0.5kW capacity requirements
should be switched via a
contactor.
Greater than 100000 cycles (all
The XE70 range is CE, RoHs and WEEE
loads) for thermostat contacts
compliant. For regulatory information, DoC/CoC
Operational life at 230V; greater than 6000 Approvals
D0045 is available on request. Product must be
operations for all manually
wired as shown for CE compliance.
operated swtiches

30
SPLIT TYPE
Air-to-water Heat Pump Split Versati

NOTE
• Never use 230V AC and 24V AC thermostat at the same time, otherwise, it will cause short circuit and power cut-off
by the circuit breaker;
• Setting temperature by the thermostat(heating or cooling) should be within the temperature range of the product;
• For other constrains, please refer to previous pages about the remote air temperature sensor;
• Do not connect external electric loads. Wire 230V AC(24V AC) and 230V GND(24V GND) should be used only for the
electric thermostat;
• Never connect external electric loads such as valves, fan coil units, etc. If connected, the mainboard of the unit can be
seriously damaged;
• Installation of the thermostat is very similar to that of the remote air temperature sensor.
• “OFF” interfaces can be kept vacant and no adverse effect will be produced for nomrla operation. When signals for
both heating and cooling are not detected, it can be considered the thermostat is “OFF”.

11. 2-Way Valve


The 2-way valve 1 is required to control water flow for cooling or heating operation. The role of 2-way valve 1 is
to cut off water flow into the underfloor loop when the fan coil unit is equipped for cooling operation.
General Information
Type Power Operating Mode Supported

Closing water flow Yes


NO 2-wire 230V 50Hz ~AC
Opening water flow Yes

Closing water flow Yes


NC 2-wire 230V 50Hz ~AC
Opening water flow Yes
(1) Normal Open type. When electric power is NOT supplied, the valve is open. (When electric power is
supplied, the valve is closed.)
(2) Normal Closed type. When electric power is NOT supplied, the valve is closed. (When electric power is
supplied, the valve is open.)
How to Wire 2-Way Valve:
Follow steps below to wire the 2-way valve.
Step 1. Uncover the front cover of the unit and open the control box.
Step 2. Find the terminal block and connect wires as below.

XT2 4 5 6
L2(ON)
L1(OFF)

2-Way Valve 1

WARNING
• Normal Open type should be connected to wire (ON) and wire (N) for valve closing in cooling mode.
• Normal Closed type should be connected to wire (OFF) and wire (N) for valve closing in cooling mode.
• (ON) : Line signal (for Normal Open type) from PCB to 2-way valve
• (OFF) : Line signal (for Normal Closed type) from PCB to 2-way valve
• (N) : Neutral signal from PCB to 2-way valve

31
Air-to-water Heat Pump Split Versati SPLIT TYPE

12. 3-Way Valve


The 3-way valve 2 is required for the sanitary water tank. Its role is flow switching between the under floor
heating loop and the water tank heating loop.
General Information
Type Power Operating Mode Supported

SPDT Selecting “Flow A” between “Flow A” and “Flow B” Yes


230V 50Hz ~AC
3-wire Selecting “Flow B” between “Flow B” and “Flow A” Yes

(1) SPDT = Single Pole Double Throw. Three wires consist of Live1 (for selecting Flow B), and Neutral (for
common).
(2) Flow A means 'water flow from the indoor unit to under floor water circuit'.
(3) Flow B means 'water flow from the indoor unit to sanitary water tank'.
Follow steps below to wire the 3-way valve:
Follow below procedures Step 1 ~ Step 2.
Step 1. Uncover front cover of the unit and open the control box.
Step 2. Find terminal block and connect wires as below.

XT2 1 2 3
L2(ON)
L1(OFF)

3-Way Valve 2

WARNING
• The 3-way valve should select water tank loop when electric power is supplied to wire (OFF) and wire (N).
• The 3-way valve should select under floor loop when electric power is supplied to wire (ON) and wire (N).
• (ON): Line signal (Water tank heating) from the main board to the 3-way valve
• (OFF): Line signal (Under floor heating) from the main board to the 3-way valve
• (N): Neutral signal from the main board to the 3-way valve

13. Other Auxiliary Heat Sources


Other auxiliary heat sources are allowed for the equipment and controlled in such a way that the mainboard will
output 230V when outdoor temperature is lower than the set point for startup of the auxiliary heat source.

XT2 7 8

Other Thermal

14. Gate-controller
If there is gate control function, installation guide follow as:
(1) GRS-CQ8.0Pd/NaE-K,GRS-CQ10Pd/NaE-K, GRS-CQ12Pd/NaE-K, GRS-CQ14Pd/NaE-K,GRS-CQ16Pd/
NaE-K

XT4 3 4

Gate-Controller

32
SPLIT TYPE
Air-to-water Heat Pump Split Versati

(2) GRS-CQ12Pd/NaE-M,GRS-CQ14Pd/NaE-M,GRS-CQ16Pd/NaE-M

XT4 25 26

Gate-Controller

15. Charging and Discharging of Refrigerant


(1) Before shipped out from manufacturer, the outdoor unit has been filled with refrigerant. Additional refrigerant
may be filled when carrying out site connection of pipelines.
(2) Check the liquid valve and the gas valve of the outdoor unit. The valves shall be completely shut off.
(3) Connect a vacuum pump to the liquid valve and the gas valve of the outdoor unit to remove air from the
inside of the indoor unit and the connecting pipe. Refer to the following figure:
Pressure meter Pressure meter

“Lo”knob “HI”knob

Liquid valve
Vacuum pump

Connection pipe

Gas valve

(4) After confirming that there is no leakage from the system, when the compressor is not in operation, charge
additional R410A working fluid with specified amount to the unit through the filling opening of the liquid pipe
valve of the outdoor unit.
• Be sure to charge the specified amount of refrigerant in liquid state to the liquid pipe. Since this
refrigerant is a mixed refrigerant, adding it in gas form may cause the refrigerant composition to change,
preventing normal operation.
• Before charging, check whether the refrigerant cylinder is equipped with a siphon tube or not.

With siphon tube No siphon tube

WARNING
• When charging is interrupted or finished, reinspect the unit but do not let the compressor run into operation.

NOTE
• Do not use mixture of refrigerant vapor and air or oxygen for pressurizing for fear of explosion.

33
Air-to-water Heat Pump Split Versati SPLIT TYPE

16. Refrigerant Collecting


When relocating or disposing of the indoor/outdoor unit, pump down the system following the procedure below
so that no refrigerant is released into the atmosphere.
(1) Turn off the power supply (circuit breaker).
(2) Connect the low-pressure valve on the gauge manifold to the charge plug (lowpressure side) on the outdoor
unit.
(3) Close the liquid stop valve completely.
(4) Supply power (circuit breaker).
Start-up of the indoor-outdoor communication takes about 3 minutes after the power (circuit breaker) is turned
on. Start the pump-down operation 3 to 4 minutes after the power (circuit breaker) is turned on.
(5) Perform the refrigerant collecting operation (pump down mode).
Hold pressing UP key 5 seconds at the homepage to enter pump down mode.

(6) Fully close the ball valve on the gas pipe side of the outdoor unit when the pressure gauge on the gauge
manifold shows 0.05 to 0 MPa [Gauge] (approx. 0.5 to 0 kgf/cm²) and quickly stop the air conditioner. Then
press UP key or Down key or ON/OFF key can exit pump down mode.

(7) Turn off the power supply (circuit breaker), remove the gauge manifold, and then disconnect the refrigerant
pipes.

WARNING
• When pumping down the refrigerant, stop the compressor before disconnecting the refrigerant pipes.
• If the refrigerant pipes are disconnected while the compressor is operating and the stop valve (ball valve) is open, the
pressure in the refrigeration cycle could become extremely high if air is drawn in, causing the pipes to burst, personal
injury, etc.

34
SPLIT TYPE
Air-to-water Heat Pump Split Versati

17. Handling of the Unit


During installing or moving the unit, other substances except refrigerant cannot get into the refrigerant pipe and
there shall not be air remained in the pipe.
If air or other substance gets into the pipe, system pressure will increase and compressor will be damaged.
Do not charge refrigerant of other type into the unit during installing or moving. Otherwise, it may cause poor
operation, malfunction, mechanical failure, or even serious safety accident.
If the refrigerant shall be recycled during moving or maintaining, pressure meter must be used. Set the unit in
cooling mode and close the valve at high pressure side (liquid valve) completely. When the reading of pressure
meter ranges 0~0.05MPa (about 30s~40s), close the valve at high pressure side (gas valve) completely, turn off
the unit and cut off power supply.
If refrigerant recycle time is too long, air may get into the system. In this case, system pressure will increase and
compressor will be damaged.
During recycling refrigerant, make sure the liquid valve and gas valve are closed completely, and the power
supply is cut off before disassembling the connection pipe.
If connection pipe is disassembled when the compressor is still operating, air may get into the system. In this
case, system pressure will increase and compressor will be damaged.
During installing the unit, make sure the connection pipe is connected properly before starting the compressor.
If the compressor is started before finishing connection of connection and when the cut-off valve is opened, air
may get into the system. In this case, system pressure will increase and compressor will be damaged.
The indoor unit and outdoor unit shall be connected properly with required wire. The wiring terminal shall be
secured properly without affecting by exterior force directly.
If the wire is not connected properly or the wiring terminal is not secured properly, fire hazard may be caused.
The wire cannot be refit or reconnected in the middle.
When the length of connection wire is not sufficient, please contact the appointed after-sales service center to
purchase a specialized wire with sufficient length.

35
Air-to-water Heat Pump Split Versati SPLIT TYPE

18. Installation of Insulated Water Tank


18.1 Installation measure
The insulated water tank should be installed and keep levelly within 5m and vertically within 3m from the indoor
unit. It can be installed in the room.
Standing water tank must be installed vertically with the bottom on the ground, never suspended. Installation
place must be firm enough and the water tank should be fixed on the wall with bolts to avoid vibration, as shown in
the following figure. Weight capacity of water tank during installation should also be considered.
Water Tank

Fix
With
Bolts
Installed on the ground
and never suspended

The minimum clearance from the water tank to combustible surface must be 500mm.
There should be water pipe, hot water joint and floor drain near the water tank in favor of water replenishment,
hot water supply and drainage of water tank.
Connection of inlet/outlet waterway: Connect the safety check valve attached with the unit (with the arrow on it
pointing at the water tank) with the water inlet of water tank with PPR pipe according to the following figure, sealing
with unsintered tape. The other end of the safety check valve should connect with tap water joint. Connect the hot
water pipe and water outlet of water tank with PPR pipe.

Safety check valve


Tap water

Note
(a) For safe use of water, water outlet/inlet of water tank must connect with a certain length of PPR pipe ,L
≥70×R2(cm, R is inside radius of the pipe). Moreover, heat preservation should be conducted and metal pipe
cannot be used. For the first use, water tank must be full of water before the power is on.

36
SPLIT TYPE
Air-to-water Heat Pump Split Versati

18.2 Outline dimension and parameter of water tank

SXVD200LCJ/A-K SXVD200LCJ2/A-K SXVD300LCJ/A-K SXVD300LCJ2/A-K


Model SXVD200LCJ/A-M SXVD200LCJ2/A-M SXVD300LCJ/A-M SXVD300LCJ2/A-M
SXVD200LCJ/A-H SXVD200LCJ2/A-H SXVD300LCJ/A-H SXVD300LCJ2/A-H
Litre 200L 200L 300L 300L
Coil specification SUS304 Ф22X0.8
M \ 10m \ 10m
Coil length
N 13m 13m 18.5m 18.5m
D(mm) 540 620
D1(mm) 438 528
H(mm) 1595 1620
A(mm) 272 280
B(mm) 105
C(mm) 112
E(mm) 432 464
F(mm) 431 399
I(mm) \ 80 \ 95
J(mm) \ 247.5 \ 202.5
K(mm) 739 718
Outline (Diameter×H)
Φ540×1595 Φ620×1620
(mm)
Package
1623×628×645 1648×708×725
(W×D×H) (mm)
Net weight kg 68 71 82 87

Gross weight kg 77 80 92 97

37
Air-to-water Heat Pump Split Versati SPLIT TYPE

Joints Dimension

Description Joint pipe thread

Hot water outlet of water tank 1/2″Female BSP

Circulating water inlet/outlet of water tank 3/4″Female BSP

Cooling water inlet of water tank 1/2″Female BSP

Pipe joint 3/4″Female BSP

18.3 Connection of waterway system


(1) If connection between water tank and indoor unit should be through the wall, drill a hole φ70 for pass of
circulating water pipe. It is unnecessary if the hole is not needed.
(2) Preparation of pipelines: Circulating water outlet/inlet pipe must be hot water pipe, PPR pipe with nominal
out diameter of dn25 and S2.5 series (wall thickness of 4.2mm) being recommended. Cooling water inlet
pipe and hot water outlet pipe of water tank should also be hot water pipe, PPR pipe with nominal out
diameter of dn20 and S2.5 series (wall thickness of 3.4mm) being recommended. If other insulated pipes
are adopted, refer to the above dimensions for out diameter and wall thickness.
(3) Installation of circulating water inlet/outlet pipes: connect the water inlet of the unit with circulating outlet of
water tank and water outlet of unit with circulating inlet of water tank.
(4) Installation of water inlet/outlet pipes of the water tank: safety check valve, filter and cut-off valve must be
installed for the water inlet pipe according to the installation sketch of the unit. At least a cut-off valve is
needed for the water outlet pipe.
(5) Installation of blow-off pipes at the bottom of water tank: connect a piece of PPR pipe with drainage outlet
to floor drain. A cut-off valve must be installed in the middle of the drainage pipe and at the place where it is
easy to be operated by the users.
(6) After connection of all waterway pipelines, perform the leakage test firstly. After that, bind up the water
pipes, water temp sensor and wires with wrapping tapes attached with the unit.
(7) Refer to Installation Sketch of the Unit for details.

Indoor Unit

Other Thermal sensor (less than 5 meters)

Water Tank

Hot water output

Other
Thermal
System
Temp Sensor 1
Safety check
valv e Filter

Tap water
Cool Water Temp sensor 2
Inlet

Blow-off Outlet
Power cord of booster heater Cut-off valve

38
SPLIT TYPE
Air-to-water Heat Pump Split Versati

Description Joint pipe thread

Circulating water inlet/outlet of main unit 1″Male BSP

Cooling water inlet of water tank 1/2″Female BSP

Circulating water inlet/outlet of water tank 3/4″Female BSP

Hot water outlet of water tank 1/2″Female BSP

Notes
(a) Distance between indoor unit and water tank should not exceed 5m levelly and 3m vertically. If higher,
please contact with us. Water tank on lower and main unit on higher side is recommended.
(b) Prepare the materials according to the above joints dimension. If cut-off valve is installed outside the room,
PPR pipe is recommended to avoid freeze damage.
(c) Waterway pipelines can’t be installed until water heater unit is fixed. Do not let dust and other sundries
enter into pipeline system during installation of connection pipes.
(d) After connection of all waterway pipelines, perform leakage test firstly. After that, perform heat preservation
of waterway system; meanwhile, pay more attention to valves and pipe joints. Ensure enough thickness of
insulated cotton. If necessary, install heating device for pipeline to prevent the pipeline from freezing.
(e) Hot water supplied from insulated water tank depends on pressure of water tap, so there must be supply of
tap water.
(f) During using, the cut-off valve of cooling water inlet of water tank should be kept normally on.

18.4 Electric wiring work


18.4.1 Wiring principle
General principles
(1) Wires, equipment and connectors supplied for use on the site must be in compliance with provisions of
regulations and engineering requirements.
(2) Only electricians holding qualification are allowed to perform wire connection on the site.
(3) Before connection work is started, the power supply must be shut off.
(4) Installer shall be responsible for any damage due to incorrect connection of the external circuit.
(5) Only copper wires are allowed to be used.
(6) Connection of power cable to the electric cabinet of the unit
(7) Power cables should be laid out through cabling trough, conduit tube or cable channel.
(8) Power cables to be connected into the electric cabinet must be protected with rubber or plastic to prevent
scratch by edge of metal plate.
(9) Power cables close to the electric cabinet of the unit must be fixed reliably to make the power terminal in
the cabinet free from an external force.
(10) Power cable must be grounded reliably.

39
Air-to-water Heat Pump Split Versati SPLIT TYPE

18.4.2 Specification of power supply wire and leakage switch


Power cable specifications and Leakage switch types in the following list are recommended.
Minimum
Leakage Minimum Sectional Sectional Area
Power Supply
Model Switch Area of Earth Wire of Power Supply
Wire
V,Ph,Hz (A) (mm2) (mm2)

GRS-CQ8.0Pd/NaE-K(O) 20 3.3 2×3.3

GRS-CQ10Pd/NaE-K(O) 20 3.3 2×3.3


220-240,~,50Hz
GRS-CQ8.0Pd/NaE-K(I) 50 13.3 2×13.3

GRS-CQ10Pd/NaE-K(I) 50 13.3 2×13.3

GRS-CQ12Pd/NaE-K(O) 30 5.3 2×5.3

GRS-CQ14Pd/NaE-K(O) 30 5.3 2×5.3

GRS-CQ16Pd/NaE-K(O) 30 5.3 2×5.3


220-240,~,50Hz
GRS-CQ12Pd/NaE-K(I) 50 13.3 2×13.3

GRS-CQ14Pd/NaE-K(I) 50 13.3 2×13.3

GRS-CQ16Pd/NaE-K(I) 50 13.3 2×13.3

GRS-CQ12Pd/NaE-M(O) 25 3.3 4×3.3

GRS-CQ14Pd/NaE-M(O) 25 3.3 4×3.3

GRS-CQ16Pd/NaE-M(O) 25 3.3 4×3.3


380-415,3N~,50Hz
GRS-CQ12Pd/NaE-M(I) 20 3.3 4×3.3

GRS-CQ14Pd/NaE-M(I) 20 3.3 4×3.3

GRS-CQ16Pd/NaE-M(I) 20 3.3 4×3.3


Notes
(a) Leakage Switch is necessary for additional installation. If circuit breakers with leakage protection are in use,
action response time must be less than 0.1 second, leakage circuit must be 30mA.
(b) The above selected power cable diameters are determined based on assumption of distance from the
distribution cabinet to the unit less than 75m. If cables are laid out in a distance of 75m to 150m, diameter of
power cable must be increased to a further grade.
(c) The power supply must be of rated voltage of the unit and special electrical line for air-conditioning.
(d) All electrical installation shall be carried out by professional technicians in accordance with the local laws
and regulations.
(e) Ensure safe grounding and the grounding wire shall be connected with the special grounding equipment of
the building and must be installed by professional technicians.
(f) The specifications of the breaker and power cable listed in the table above are determined based on the
maximum power (maximum amps) of the unit.
(g) The specifications of the power cable listed in the table above are applied to the conduit-guarded multi-wire
copper cable (like, YJV XLPE insulated power cable) used at 40℃ and resistible to 90℃ (see IEC 60364-5-52).
If the working condition changes, they should be modified according to the related national standard.Power
lines used outdoor should at least comply with 60245 IEC57.
(h) The specifications of the breaker listed in the table above are applied to the breaker with the working
temperature at 40℃ . If the working condition changes, they should be modified according to the related national
standard.

40
SPLIT TYPE
Air-to-water Heat Pump Split Versati

19. Wring Diagram


19.1 Control Board
(1) Main Board (AP2): GRS-CQ8.0Pd/NaE-K(O),GRS-CQ10Pd/NaE-K(O) , GRS-CQ12Pd/NaE-K(O)),GRS-
CQ14Pd/NaE-K(O), GRS-CQ16Pd/NaE-K(O),GRS-CQ12Pd/NaE-M(O), GRS-CQ14Pd/ NaE-M(O),GRS-
CQ12Pd/NaE-M(O)
AC_N AC_L 4V VA-1 HEAT FA

H-PRESS

CN8

COM-ESPE2
CN7
PWR1 HPP

DC-MOTOR0
T-SENSOR3

DC-MOTOR1 CN5 T-SENSOR2


Silk Screen Specification

AC_N Neutral wire input of power supply

AC_L Live wire input of power supply

4V 4-way valve

VA-1 E-heater of chassis

HEAT Electric heating tape

FA To EXV1,pipe electric expansion valve,1-4 pin: driving impulse output; 5 pin: +12V;

H-PRESS Signal input of pressure sensor 1 pin: GND; 2 pin: signal input; 3 pin: +5V;
To the wired controller, communication cable: 1 pin earthed, 2 pin B, 3 pin A, 4 pin+12power
CN8
supply;
CN7 Communication between AP1 and AP2;communication cable 2 pin B, 3 pinA

COM-ESPE2 Pin for communication with the drive

HPP High pressure switch

T-SENSOR3 1 hole: +3.3V 2 hole: detection ; suction temperature sensor

T-SENSOR2 1, 2 hole: pipe temperature; 3, 4 hole: environment; 5, 6 hole: exhaust

CN5 Supply 18V DC power to the drive.


DC fan 1 pin: strong power supply; 3 pin: fan GND; 4 pin: +15V; 5 pin: control signal;
DC-MOTOR1
6pin:feedback signal;
DC fan 1 pin: strong power supply; 3 pin: fan GND; 4 pin: +15V; 5 pin: control signal;
DC-MOTOR0
6pin:feedback signal;
PWR1 Supply 310V DC power to the drive.

41
Air-to-water Heat Pump Split Versati SPLIT TYPE

(2) Main Board (AP1): GRS-CQ8.0Pd/NaE-K(I),GRS-CQ10Pd/NaE-K(I) , GRS-CQ12Pd/NaE-K(I),GRS-


CQ14Pd/NaE-K(I) , GRS-CQ16Pd/NaE-K(I),GRS-CQ12Pd/NaE-M(I), GRS-CQ14Pd/NaE-M(I),GRS-
CQ16Pd/NaE-M(I)
OTHER_HEAT
X10 3V1_OFF 3V2_OFF
HEAT2 2V1_OFF 2V2_OFF OTHER_HETA_DCOUT

AC-L N ERR RUN WT_HEAT HEAT1 BAN_HEAT PUMP2 2V1_ON 2V2_ON 3V1_ON 3V2_ON
PUMP1

N1

OTHER_HETA_DCIN

X23

CN33
OTHER_HETA_DCIN

CN31
CN31 COM-OUT
TR-IN

CN8 INDOOR_PUMP

TR-
CN8

TR-
POOL_PUMP

T-SEN13
SW_IN
SOLAR_PUMP
SW_SO
T-SEN12

SW_PO

T-SEN11 T-SEN9 T-SEN7 T-SEN6 T-SEN2 T-SEN4

T-SEN8 T-SEN1 T-SEN3 OVC_HEAT1 OVC_HEAT2 OVC_WT_HEAT


T-SEN10 DOOR_IN
T-SEN5

Silk Screan Location Introduction

AC-L AC-L Live wire of power supply

N N Neutral wire of power supply

N1 N1 Reserved

TR-IN CN1 220V input of transformer

TR-OUT1 CN2 Transformer output 1 (12V)

TR-OUT2 CN3 Transformer output 2 (24V)

X23 X23 To the ground (Reserved)

Leaving Water Temperature of the PHE

T-SEN5 CN10 Entering Water Temperature of the PHE

Liquid Temperature Sensor of the PHE

T-SEN1 CN11 Water Tank Temperature Sensor 1

T-SEN6 CN12 Water Tank Temperature Sensor 2

42
SPLIT TYPE
Air-to-water Heat Pump Split Versati

Gas Temperature Sensor of the PHE


T-SEN12 CN13
Leaving Water Temperature of the Electric Heate

T-SEN13 CN14 Remote room temp sensor2(Reserved)

T-SEN11 CN15 Remote room temp sensor1

T-SEN4 CN20 Reserved

T-SEN2 CN21 Reserved

T-SEN3 CN22 Reserved

T-SEN10 CN24 Solar water-in temp sensor

T-SEN7 CN29 Solar water-out temp sensor

T-SEN9 CN30 Solar board temp sensor

T-SEN8 CN32 Reserved

SW_SO CN16 Solar waterflow switch

SW_PO/OV_PUMP CN17 Reserved

SW_IN CN25 Indoor units waterflow switch

OVC-HEAT1 CN26 E-heater of indoor unit1 adhesion-proof protection detector

OVC-HEAT2 CN27 E-heater of indoor unit2 adhesion-proof protection detector

OVC-WT_HEAT CN28 E-heater of water tank adhesion-proof protection detector

DOOR_IN CN23 Door detection input

CN18 CN18 Power supply interface of the thermostat (220~240V)

HEAT_M2

COOL_M2
CN31 Power supply interface and control signal of the thermostat (24V)
24VAC

OFF2

OFF1

HEAT_M1 CN33 Control signal of the thermostat

COOL_M1

COM_OUT CN5 Connect to AP2

COM_MANUAL CN6 Connect the wired controller

COM_BMS CN19 Reserved

OTHER_HEAT_DCOUT X1 The dc output of assistant heat

OTHER_HEAT_DCIN X2 The dc input of assistant heat

RUN X15 Running indicator

ERR X19 Error indicator

WT­_HEAT X16 E-heater of water tank

HEAT1 X17 E-heater 1

HEAT2 X18 E-heater 2

BAN_HEAT X3 Reserved

PUMP1 X5 Reserved

OTHER_HEAT X6 Assistant heat by 220VAC

PUMP2 X9 Reserved

X10 X10 Reserved

43
Air-to-water Heat Pump Split Versati SPLIT TYPE

2V1_ON X7 Electric magnetic 2-way valve 1 is normally open

2V1_OFF X8 Electric magnetic 2-way valve 1 is normally closed

3V2_ON X12 Electric magnetic 3-way valve 2 is normally open

3V2_OFF X11 Electric magnetic 3-way valve 2 is normally closed

INDOOR_PUMP CN4 Control of the water pump for the main unit

CN8 CN8 Reserved

SOLAR_PUMP CN7 Control of the water pump for solar system

44
SPLIT TYPE
Air-to-water Heat Pump Split Versati

(3) Drive Board (AP4): GRS-CQ8.0Pd/NaE-K(O),GRS-CQ10Pd/NaE-K(O)


P-OUT DC-BUS1
L2-1
G-OUT L1-2

PWR

L1-1 AC-L COMM1 COMM

L2-2 N
Silk Screen Introduction

AC-L Live line input of the drive board

N Neutral line input of the drive board

L1-1 To PFC inductor brown line

L1-2 To PFC inductor white line

L2-1 To PFC inductor white line

L2-2 To PFC inductor blue line

U To compressor phase U

V To compressor phase V

W To compressor phase W

DC-BUS1 Pin for electric discharge of the high-voltage bar during test.

P-OUT Reserved

G-OUT Reserved

COMM Communication interface[1-3.3V,2-TX,3-RX,4-GND]

COMM1 Communication interface[1-3.3V,2-TX,3-RX,4-GND]

PWR Power input of the drive board [1-GND,2-18V,3-15V]

45
Air-to-water Heat Pump Split Versati SPLIT TYPE

(4) Drive Board (AP4):GRS-CQ12Pd/NaE-K(O) , GRS-CQ14Pd/NaE-K (O), GRS-CQ16Pd/NaE-K(O)


10 7
3 4 5 6

11

1
No Silk Screen Introduction

1 COMM Communication interface [1-3.3V, 2-TX, 3-RX, 4-GND]

2 PWR Switch power interface [1-310VDC, 3-GND]

3 N Neutral line input of the drive board

4 L2-2 Connector to L2-2 of PFC reactor 2

5 L2-1 Connector to L2-1 of PFC reactor 2

6 L1-1 Connector to L1-1 OF PFC reactor 1

7 W Connector to the compressor phase-W

8 V Connector to the compressor phase-V

9 U Connector to the compressor phase-U

10 L1-2 Connector to L1-2 OF PFC reactor 1

11 AC-L Live line input of the drive board

46
SPLIT TYPE
Air-to-water Heat Pump Split Versati

(5) Drive Board (AP4):GRS-CQ12Pd/NaE-M(O), GRS-CQ14Pd/NaE-M(O), GRS-CQ16Pd/NaE-M(O)

14
13
12

3
4

8 7 6
11 10 9

No Silk Screen Introduction

1 COMM Communication interface [1-3.3V, 2-TX, 3-RX, 4-GND]

2 PWR Switch power interface [1-310VDC, 3-GND]

3 X1 Connector to filter R

4 X2 Connector to filter S

5 X3 Connector to filter T

6 X6 Connector to T-1 OF PFC reactor 3

7 X5 Connector to S-1 OF PFC reactor 2

8 X4 Connector to R-1 OF PFC reactor 1

9 X7 Connector to T-2 of PFC reactor 3

10 X8 Connector to R-2 of PFC reactor 2

11 X9 Connector to S-2 of PFC reactor 1

12 X503 Connector to the compressor phase-W

13 X502 Connector to the compressor phase-V

14 X501 Connector to the compressor phase-U

47
Air-to-water Heat Pump Split Versati SPLIT TYPE

(6) Filter Board (AP3):GRS-CQ8.0Pd/NaE-K(O),GRS-CQ10Pd/NaE-K(O)


AC-N AC-L

N-OUT

L-OUT

E1
Silk Screen Introduction

AC-N Neutral line of the power supply for the main unit

AC-L Live line of the power supply for the main unit

Neutral line output of the filter board (to the drive board)
N-OUT
Neutral line output of the filter board (to the main board )

L-OUT Live line output of the filter board (to the drive and main boards)

E1 To the grounding line of the main unit

(7) Filter Board (AP3):GRS-CQ12Pd/NaE-K(O), GRS-CQ14Pd/NaE-K(O) , GRS-CQ16Pd/NaE-K(O)

N-OUT

AC-N

L-OUT
AC-L

Silk Screen Introduction


AC-N Neutral line of the power supply for the main unit
AC-L Live line of the power supply for the main unit

Neutral line output of the filter board (to the drive board)
N-OUT
Neutral line output of the filter board (to the main board )

L-OUT Live line output of the filter board (to the drive and main boards)

48
SPLIT TYPE
Air-to-water Heat Pump Split Versati

(8) Filter Board (AP3):GRS-CQ12Pd/NaE-M(O), GRS-CQ14Pd/NaE-M(O), GRS-CQ16Pd/NaE-M(O)

X4

X7 X3

X6 X2

X5 X1

No. Silk Screen Introduction

1 X1 U line of the power supply for the main unit

2 X2 V line of the power supply for the main unit

3 X3 W line of the power supply for the main unit

4 X4 Ground line of the power supply for the main unit

5 X5 U line output of the filter board (to the drive board)

6 X6 V line output of the filter board (to the drive board )

7 X7 W line output of the filter board (to the drive and main boards)

19.2 Electric Wiring


19.2.1 Wiring principle
Refer to Section 18.4.

49
Air-to-water Heat Pump Split Versati SPLIT TYPE

19.2.2 Electric wiring design


The wiring diagram stuck to the unit always prevails.
(1) Wiring diagram: indoor unit
GRS-CQ8.0Pd/NaE-K(I), GRS-CQ10Pd/NaE-K(I), GRS-CQ12Pd/NaE-K(I), GRS-CQ14Pd/NaE-K(I), GRS-
1 CQ16Pd/NaE-K(I) 2 3 4 5 6 7 8

A PE PE A
XT1
CODE NAME
Power
1 20K RT1 AP Main Board Only For RT6
L AC-L

2 AP1 Indoor unit Main Board


N N
5
20K RT2 EH1 Water side electrical heater1
3 6 4 CN10
1 1 EH2 Water side electrical heater2
Water tank Auxiliary

6 XT2
4 8 2 L1(OFF) 36 20K RT3
N 2 1 X11 HL1 Running indicating lamp
electric heater

valve2
27 37

3-way
KM3 L2(ON)
2 X12
7 8 9 10
N
3
HL2 Error indicating lamp
L1(OFF) 38
PE PE 4 X8
HT1 Temperature limiter 1

valve1
28

2-way
L2(ON) 39 20K RT8
5 X7
Consumer Connection
N
6 20K
HT2 Temperature limiter 2
40 CN13 RT9
7 X6
KM1 Auxiliary electric heater 1 AC contactor

thermal
29
N

Other
8
2

B
B KM2 KM1
KM2 Auxiliary electric heater 2 AC contactor
XT3
HL1
9
41 50K RT4 KM3 Water tank Auxiliary electric heater AC contactor
8

Running Indi- X15


6

N 30 CN11
cating lamp
WH RD
10 42 M2 Indoor unit pump
BK BU HL2
Error indi- 11 31 X19
78 50K
N RT5
17 家研
cating lamp
12 CN12 79
RT1 Water-out temp sensor of the whole unit
201 家用 HT1 RT2 Water-in temp sensor of the whole unit
15K RT7
202 试制 CN14 RT3 Liquid line temp sensor
22 质控
24 采购 Gate-controller
XT4
50K
RT4 Water-tank temp sensor1
49 RT11
3 50 CN24 RT5 Water-tank temp sensor2
29 出口 220VAC
4
CN23

361 商工 EH2 EH1


SW1 51 50K RT12
RT6 Remote room temp sensor1
43 钣金 5
6
52 CN16 CN29 RT7 Remote room temp sensor2
44 喷塑
46 两器 50K RT13 RT8 Gas line temp sensor
C CN30 C
47 管一 RT9 Auxiliary heater leaving water temp sensor
48 模具
XT5 RT11 Solar water-out temp sensor
49 筛选 HEAT
17
60 AP1 HT2
XT2
RT12 Solar water-in temp sensor
COOL 61 17 22 23
Thermostat

50 控制 PE PE 18 X17 KM1 1 3
62 0 1 2
51 空四
Electrical heater Electrical box 24VACGND
19 CN31 18 RT13 Solar Board temp sensor
Earthing Earthing 24VAC 63 19
20 X18
0 KM2 1 SW1 Solar waterflow switch
55 管二 OFF 64
21 11
62 重庆
OFF 57 CN26 12
KM1-6 SW3 Indoor units waterflow switch
79 小家电 22
HEAT
23
58
CN33 TC Transformer
61 巴西 COOL 59 13
24 KM2-6 XT1 Terminal block(L,N,1,2)
Thermostat

CN27 14
Specification: 15
XT2 Terminal block(1~8)
XT6 KM3-6
N
33
55 CN28 16 XT3 Terminal block(9~16)
1. The wires in the imaninal frames L(220VAC)
34
56 CN18
21 20
XT3 XT4 Terminal block(1~6) D
D are connected by the consumer. Solar-pump
70
X16
0
KM3 1 12
XT5 Terminal block(17~24)
35 71
是否属于客 control signal 36 72 SW3 XT6 Terminal block(33~40)
户化物料 CN7 CN25

2. power supply for Thermostat: If it Solar-pump fault
feedback signal
37 73
38

is 24V AC, Please connect Terminal 2
15K RT6
74 CN15
block(XT5) 17.18.19.20.21; If it is Pump Control
signal (OUT)
39 75 CN8 Electric component position map
使用范围 40 CN1 AP
220V AC, please connect Terminal
通用 TC
block(XT5) 22.23.24 and connect

KM3
4 Display
出口 CN6

XT3

XT6
Terminal block(XT6) 33.34. board

XT1
内销 Communication Line

KM2
AP2 3 AP1
CN7 CN5
BK/BN

XT4
M2 KM1-4

XT2

XT5
CN4 BU KM1
KM1-2
OUTDOOR
UNIT CN1 CN2 CN3 YE/GN HT2
地点 状态 PE PE E
E
是否需
管一
要加工 3L PE
1L
是否需 3N
管二
要加工 2L

借通用登记 1N
TC 2N

物料状态
钣金
喷塑 印刷线路图技术要求:
GRS-CQ12Pd/NaE-M(I), GRS-CQ14Pd/NaE-M(I),GRS-CQ16Pd/NaE-M(I)
两器
管路 1.严格按图幅比例,图文正确,画面优美;
机加件 1 2.图幅为白底黑字; 2 3 4 5 6 D 换版 许海强 7
170913 材料:光白PET 8
采购 C 2 许海强 161011 F
注塑
3.用湿布擦15秒,再用浸汽油布擦15秒,图文仍清晰明了; B 换版 许海强 160125
F 喷涂 4.材料为光白PET; 标记 处数分区 更改文件号 签名 年月日 产品型号:
GRS-CQ16Pd/NaE-K(I)

丝印 线路图
控制
5.印刷线路图尺寸为:外框300X200(宽X高),内框296X196(宽X高), 设计 许海强 151215 标准化
图样标记 重量 比例
预装 Power XT1
外框圆角半径为R4,内框圆角半径为R2,尺寸公差为±1。 审核 数据审核
A W15 RT1 20K S 物料编码: 600007000179
下料 L1
6.其余应符合 L1
QJ/GD 41.12.001的要求。 AC-L 工艺 审定 A
会签 CODE
批准 共 1张
NAME 第 1张 GRSCQ16PdNaEKI.XL
L2 L2 RT2
1 2 3 4 5 620K 7 8
CN10 AP Main Board Only For RT6
L3 L3
AP1 Main PCB
W14 RT3 20K
N N N EH1 Auxiliary electric heater
HL1 Running indicating lamp
PE PE XT2 RT8 20K HL2 Error indicating lamp
W8 W9 W10 L1(OFF) W48
W45
3-way L2(ON) 1 W49 X11 CN13 HT1 Thermostat (WP95A-R)
XT4 KM2 valve2 2 X12 RT9
N
3
20K HT2 Thermostat (WP75A-R)
W16 2 1 W5 L1(OFF) W52
29 2-way L2(ON) 4 W50 W53 X8 KM1 Auxiliary electric heater AC contactor
5
Water tank Auxiliary

W17 4 3 W6 valve1 N
X7 RT4
30 6
50K KM2 Water tank Auxiliary electric heater AC contactor
Other
W55 CN11 B
B 7 X6
electric heater

6 5 M3 Indoor unit pump


1

W18 W7 N W51
31 KM1 thermal 8 W41 RT5 50K
RT1 Water-out temp sensor of the whole unit
CN12 W42
2

XT3 RT2 Water-in temp sensor of the whole unit


PE PE HL1 W54 W57 RT7 15K
17 家研
Running 9 X15
CN14 RT3 Liquid line temp sensor
indicating lamp N
HT1 10 W58
201 家用 Error indicating
HL2
11 X19 RT4 Water-tank temp sensor 1
N W59 RT11 50K
202 试制 lamp 12 RT5 Water-tank temp sensor 2
CN24
22 质控 RD BK BU RT6 Remote Air temp sensor 1
24 采购 RT12 50K
29 出口 CN29 RT7 Remote Air temp sensor 2
361 商工 XT5 RT8 Gas line temp sensor
HEAT W65 RT13 50K
Thermostat

43 钣金 17 RT9 Auxiliary heater water-out temp sensor


1

EH1 COOL W66 CN30


44 喷塑 18 W67
24VACGND CN31
19 RT11 Solar water-out temp sensor
4

6
2

46 两器 24VAC W68 SW3


C 20 C
47 管一 OFF W69 CN25 RT12 Solar water-in temp sensor
21
48 模具 W85 RT13 Solar board temp sensor
KM1-2
49 筛选 OFF W70 CN26 W86 SW1 Solar waterflow switch
PE PE HEAT
22 W71
50 控制 23 CN33 SW3 Indoor units waterflow switch
Thermostat

COOL W72 W87 W94


KM1

Electrical heater Electrical box 24 X17


51 空四
Earthing Earthing A1 A2 TC Transformer
55 管二 HT2
1

XT6 XT1 Terminal block(L1,L2,L3,N)


62 重庆
N W63 W91
33 KM2-2 XT2 Terminal block(1~8)
2

79 小家电 L(220VAC) W64 CN18 CN28 W92


Specification: 34
AP1
W96
61 巴西 XT7 XT3 Terminal block(9~16)
1. The wires in the imaninal frames are W93 W97
KM2

W77
X16 2 XT4 Terminal block(25~32)
A1 A2
connected by the consumer. Solar-pump 35 W78 XT5 Terminal block(17~24)
control signal 36 W79 CN7 CN1
Solar-pump fault 37 1L 1N XT6 Terminal block(33~40)
W80
2. power supply for Thermostat: If it is 24V AC, feedback signal 38 TC D
D
XT7 Terminal block(1,2)
Please connect Terminal block(XT5) Pump Control 39
W81 3L 3N 2L 2N
是否属于客 W82 CN8 CN2
户化物料
17.18.19.20.21; If it is 220V AC, please signal (OUT)
40
是 connect Terminal block(XT5) 22.23.24 and
CN3
否 connect Terminal block(XT6) 33.34.
使用范围 XT4 2 15K RT6
Gate controller W102 CN15
通用 25
220VAC W103 CN23
26 CN1 AP
出口
内销
Electric component position map SW1
27
W104
W105 CN16
28 4 Display
CN6
board
XT1

KM2
XT6
XT3

Communication Line XT7


E 地点 状态 BN W113 E
XT4

TC AP1 3 CN4 M3
BU
1 W114
XT1-L1
管一
是否需 CN7 CN5 2 XT1-N
要加工
YE/GN
XT2

XT5

是否需 OUTDOOR
XT7

管二
要加工 KM1 UNIT AP2
HT2
借通用登记 PE

物料状态
钣金
喷塑 印刷线路图技术要求:
两器 1.严格按图幅比例,图文正确,画面优美;
管路
机加件 2.图幅为白底黑字; 材料:光白PET
采购 3.用湿布擦15秒,再用浸汽油布擦15秒,图文仍清晰明了; F
注塑 F 换版 许海强 170913
F 喷涂 4.材料为光白PET; 标记 处数分区 更改文件号 签名 年月日 产品型号:
GRS-CQ16Pd/NaE-M(I)

丝印 5.印刷线路图尺寸为:外框300X200(宽X高),内框296X196(宽X高), 线路图

50
设计 许海强 160105 标准化 重量
控制 图样标记 比例
预装 外框圆角半径为R4,内框圆角半径为R2.尺寸公差为±1; 审核 数据审核
下料 6.其余应符合 QJ/GD 41.12.001的要求。 工艺 审定 S 物料编码: 600007000180

会签 批准 共 1张 第 1张 GRSCQ16PdNaEMI.XL
1 2 3 4 5 6 7 8
SPLIT TYPE
Air-to-water Heat Pump Split Versati
2 3 4 5 6 7 8

(2) Wiring diagram: outdoor unit


• GRS-CQ8.0Pd/NaE-K(O),GRS-CQ10Pd/NaE-K(O)

Power XT1
L4
L
24
AC-L CODE NAME
E1
25 AP3 AP2 Outdoor unit Main Board
N AC-N

26
L5
L-OUT N-OUT
80 AP3 Filter Board
AP4 Drive Board
COMP Compressor
PE 84 83 85 PE
EH4 Compressor band heater
EH5 Bottom band heater
L2 L6 L3
20K RT14 82
AC-L
X2 X1
EKV1 Electronic expansion valve coil1
15K RT15
AC-N
81 HP High pressure switch
T-SENSOR2
50K RT16 86 L1 Electrical Inductance 1
CN5
87
PWR
AC-L N L2 Electrical Inductance 2
88
20K RT17 L3~L7 Magnetic ring
T-SENSOR3 LP low pressure switch
89
PE AP4 M1 DC motor
HP p 76 90
77 HPP COM-ESPE2 91 COMM RT14 Defrosting temp sensor
92 U V W
L2-1 L1-1 L1-2 L2-2
RT15 Outdoor temp sensor
LP p 79 RT16 Discharged temp sensor
78 CN4
93 94 95
YE BN WH BU
RT17 Suction temp sensor
5
4 SP1 High pressure sensor
SP1 FA
3
EKV1 L7 XT1 Terminal block(3 BIT)
2

H-PRESS
1 YV4 4-way valve coil
SP AP2 U V W

COMP
3~
L1
PE
YV4 96 Electric component position map
4V
EH4

HEAT PE L1 AP2
AP4
EH5 DC-MOTOR1

VA-1 AP3
1

3
4
5
6

Communication Line
M1 XT1
AP1 3 L2
CN5

CN7

INDOOR
UNIT PE PE PE
Earthing wire is available for iron-clad motor,
while unavailable for plastic-clad motor.

2 3 4 5 6 7 8

• GRS-CQ12Pd/NaE-K(O), GRS-CQ14Pd/NaE-K(O), GRS-CQ16Pd/NaE-K(O)


印刷线路图技术要求:
1.严格按图幅比例,图文正确,画面优美;
2.图幅为白底黑字;
CODE NAME
3.用湿布擦15秒,再用浸汽油布擦15秒,图文仍清晰明了; AP2 Outdoor unit Main Board
4.材料为0.05mm光白PET;
Power XT1
L3 L4
AP3 Filter Board 材料:0.05mm光白PET
1 AP4 Drive Board
5.印刷线路图尺寸为:外框250X180(宽X高),内框246X176(宽X高),
L L AC-L E 换版 许海强 20160317
2
L3 L4 AP3 E1 EH1 Compressor
标记 处数分区 band 更改文件号 heater 签名 年月日 产品型号:
GRS-CQ10PdNaE-K
外框圆角半径为R4,内框圆角半径为R2.尺寸公差为±1
N N
L5
N
EH2 Bottom
设计 band 2015/8/24
郑景涛 heater 标准化 线路图
DC-BUS 重量
6.其余应符合 QJ/GD
PE 41.12.001的要求3 L-OUT N-OUT
EKV Electronic expansion数据审核
审核
valve coil
图样标记 比例

HP High pressure switch 审定


工艺 S 物料编码: 600007
L1 Electrical Inductance 1
会签 批准 共 1张 第 1张 GRSCQ10PdN
PE 5 4 7 6 8 9 PE L2 Electrical Inductance 2
2 3 4 5 6 7 8
L3~L13 Magnetic ring
L8 L7 L6 L6 LP High pressure switch
20K RT1
AC-L M1 UP DC Motor
L2 L8 L7
15K RT2
AC-N
24 X1 X2 M2 Down DC Motor
T-SENSOR2
RT1 Defrosting temp sensor
50K RT3
RT2 Outdoor temp sensor
L9
10 AC-L N DC-BUS RT3 Discharged temp sensor
20K RT4
PWR1
11
L9 PWR RT4 Suction temp sensor
T-SENSOR3
SP High pressure sensor
HP p 20 12
21 HPP 13 AP4 XT1
YV1
Terminal block(3 BIT)
4-way valve coil
COM-ESPE2 14 COMM
15
LP p 22
23 LPP U V W
L2-1 L1-1 L1-2 L2-2

SP
AP2 5
16 17 18
YE BN WH BU

S H-PRESS FA
4
EKV
Electric component position map
3
P 2
L10 L10

AP3
1
L13 L13 L13 L11 L11
L1
AP4
DC-MOTOR1
4V YV1 U V W L12 L12 L2
EH1 COMP
M1 AP2
HEAT 3~
PE
EH2 L1
VA-1
19 XT1
DC-MOTOR0

Communication Line PE

3 AP1 M2
1

3
4
5
6

3
4
5
6

CN7 CN5

M1 M2
INDOOR
PE PE UNIT

PE PE

Earthing wire is available for iron-clad motor,


while unavailable for plastic-clad motor.

印刷线路图技术要求:
1.严格按图幅比例,图文正确,画面优美;
2.图幅为白底黑字;
3.用湿布擦15秒,再用浸汽油布擦15秒,图文仍清晰明了; 51 材料:光白PET
4.材料为光白PET; C 换版 许海强 160224
5.印刷线路图尺寸为:外框200X150(宽X高),内框196X146(宽X高), B 换版 许海强 151215
GRS-CQ16Pd/NaE-K(O)
标记 处数分区 更改文件号 签名 年月日 产品型号:
外框圆角半径为R4,内框圆角半径为R2.尺寸公差为±1 线路图
设计 许海强 150801 标准化
6.其余应符合 QJ/GD 41.12.001的要求 图样标记 重量 比例
审核 数据审核
Air-to-water Heat Pump Split Versati SPLIT TYPE

1 2 3 4 5 6 7 8

• GRS-CQ12Pd/NaE-M(O), GRS-CQ14Pd/NaE-M(O), GRS-CQ16Pd/NaE-M(O)

CODE NAME
Power XT1
AP2 Outdoor unit Main Board
L4 L5 L6
1
L1 X1(AC-L1)
L4 L5 L6 AP3 Filter Board
2
L2 X2(AC-L2)
AP4 Drive Board
3
L4 L5 L6 AP3 X9
L3 X3(AC-L3)
EH1 Compressor band heater
L4 L5 L6
4
N X4 6
EH2 Bottom band heater
L7
5 X11(AC-L1) X8(N-F) X5(L1-F) X6(L2-F) X7(L3-F)
EKV Electronic expansion valve coil
RD HP High pressure switch
10 7 8 9
PE PE L Electrical Inductance
L8 L8 L8 L8 L1-L3 Inductor
20K RT1
AC-L LP High pressure switch
家研 L
家用
15K RT2
AC-N
BK M1 UP DC Motor
T-SENSOR2
试制 50K RT3 M2 Down DC Motor
质控
采购 11
L9
X1(R) X2(S) X3(T) RT1 Defrosting temp sensor
20K RT4
出口
T-SENSOR3
PWR1
12
L9 PWR RT2 Outdoor temp sensor
商工
钣金 HP p 27 13 RT3 Discharged temp sensor
喷塑
两器
28 HPP
COM-ESPE2
14
15 COMM AP4 RT4 Suction temp sensor
16
管一 LP p SP High pressure sensor
29
模具 30 LPP U V W X7 X8 X9 X6 X5 X4 XT1 Terminal block(5 BIT)
筛选 (X501) (X502) (X503) (R-2) (S-2) (T-2) (T-1) (S-1) (R-1)

控制 YV1 4-way valve coil


AP2
SP
5
RD BK BU BU BK RD
空四 4
S H-PRESS FA EKV 23 24 25 20 21 22 19 18 17
管二 3
P 2 Electric component position map
重庆 1
L10 L10 L10 L14 L14 L14 L12 L12 L12
家电
L2 L3
巴西 L1
DC-MOTOR1 YV1 L11 L11 L11 L15 L15 L15 L13 L13 L13 AP4
4V

EH1
U V W
HEAT
COMP L1 L2 L3 AP3
EH2
3~ M1 L
于客 VA-1 PE
DC-MOTOR0 AP2
物料 26

Communication Line XT1


3 AP1 PE
范围
1

3
4
5
6

3
4
5
6

CN7 CN5

M1 M2 M2
INDOOR
PE PE UNIT

PE PE

状态 Earthing wire is available for iron-clad motor,


否需 while unavailable for plastic-clad motor.
加工

否需
加工

19.2.3 印刷线路图技术要求:
Terminal Board
登记

状态
1.严格按图幅比例,图文正确,画面优美;
(1) 2.图幅为白底黑字;
GRS-CQ8.0Pd/NaE-K(I),GRS-CQ10Pd/NaE-K(I),GRS-CQ12Pd/NaE-K(I),GRS-CQ14Pd/NaE-K(I), GRS-


器 3.用湿布擦15秒,再用浸汽油布擦15秒,图文仍清晰明了;

4.材料为光白PET;
加件


CQ16Pd/NaE-K(I)
5.印刷线路图尺寸为:外框200X150(宽X高),内框196X146(宽X高),
B 换版 许海强 160120
材料:光白PET

涂 外框圆角半径为R4,内框圆角半径为R2.尺寸公差为±1 标记 处数分区 更改文件号 签名 年月日 产品型号:


GRS-CQ16Pd/NaE-M(O)

印 6.其余应符合 QJ/GD 41.12.001的要求 设计 许海强 150818 标准化 重量


线路图
制 图样标记 比例
装 审核 数据审核
料 工艺 审定 S 物料编码: 600007000041

会签 批准 共 1张 第 1张 GRSCQ16PdNaEMO.XL

1 2 3 4 5 6 7 8

52
SPLIT TYPE
Air-to-water Heat Pump Split Versati

(2) GRS-CQ12Pd/NaE-M(I),GRS-CQ14Pd/NaE-M(I),GRS-CQ16Pd/NaE-M(I)

20. Commissioning
20.1 Check before startup
For safety of users and unit, the unit must be started up for check before debugging. The procedures are as
below:

The following items shall be performed by qualified repair persons.


Confirm together with the sales engineer, dealer, installing contractor and customers for the following items finished or to
be finished.
No. Confirmation of Installation √
1 If the contents of Application for Installation of this Unit by Installer are real. If not, debugging will be refused. □

2 Is there written notice in which amendment items are shown in respect of unqualified installation? □

3 Are Application for Installation and Debugging list filed together? □

No. Pre-check √
1 Is appearance of the unit and internal pipeline system ok during conveying, carrying or installation? □
2 Check the accessories attached with the unit for quantity, package and so on. □
3 Make sure there is drawings in terms of electricity, control, design of pipeline and so on. □
4 Check if installation of the unit is stable enough and there is enough space for operation and repair. □
5 Completely test refrigerant pressure of each unit and perform leakage detection of the unit. □
6 Is the water tank installed stably and are supports secure when the water tank is full? □
7 Are heat insulating measures for the water tank, outlet/inlet pipes and water replenishing pipe proper? □

53
Air-to-water Heat Pump Split Versati SPLIT TYPE

Are the nilometer of water tank, water temperature indicator, controller, manometer, pressure relief valve and
8 □
automatic discharge valve etc. installed and operated properly?

9 Does power supply accord with the nameplate? Do power cords conform to applicable requirements? □

Is power supply and control wiring connected properly according to wiring diagram? Is earthing safe? Is each
10 □
terminal stable?

11 Are connection pipe, water pump, manometer, thermometer, valve etc. are installed properly? □

12 Is each valve in the system open or closed according to requirements? □


13 Confirm that the customers and inspection personnel of Part A are at site. □
14 Is Installation Check-up Table completed and signed by the installation contractor? □

NOTE: If there is any item marked with ×, please notify the contractor. Items listed above are just for reference.

General Evaluation: Debugging □ Amendment □

Judge the following items (if there is not any filling, qualification will be regarded.)
Confirmed Items after pre-checking

a: Power supply and electric control system b: Loading calculation

c: Heating problems of Unit d: Noise problem

e: Pipeline problem f: Others

Normal debugging work can’t be performed unless all installation items are qualified. If there is any problem,
it must be solved firstly. The installer will be responsible for all costs for delay of debugging and re-debugging
incurred by any problem which is not solved immediately.

Submit schedule of amending reports to installer.

Is the written amending report which should be signed after communication provided to installer?

Yes ( ) No ( )

20.2 Test run


Test run is testing whether the unit can run normally via preoperation. If the unit cannot run normally, find and
solve problems until the test run is satisfactory. All inspections must meet the requirements before performing the
test run. Test run should follow the content and steps of the table below:

The following procedure should be executed by experience and qualified maintenance men.

No. Start up the pretest procedure


Notice: before test, ensure that all power must be cut off, including the far- end power switch, otherwise, it may cause
casualty.
1 Ensure that the compressor of the unit is preheated for 8h.

NOTE: heat the lubricating oil at least 8h in advance to prevent refrigerant from mixing with the lubricating oil, which
may cause damage to the compressor when starting up the unit.
Check whether the oil temperature of the compressor is obviously higher than the outdoor ambient
2
temperature.
NOTE: if the oil temperature of the compressor is obviously higher than the outdoor ambient temperature, it means
that the heating tape of compressor is damaged. In that case, the compressor will be damaged easily. Therefore, repair
the heating tape before using the unit.
Check whether the phase sequence of the main power supply is correct. If not, correct the phase sequence
3
firstly.
NOTE: recheck the phase sequence before start-up to avoid reverse rotation of the compressor which may damage
the unit.
Apply the universal electric meter to measure the insulation resistance between each outdoor phase and earth
4
as well as between phases.
NOTE: defective earthing may cause electric shock.
No. Ready to start

54
SPLIT TYPE
Air-to-water Heat Pump Split Versati

Cut off all temporary power supply, resume all the insurance and check the electricity for the last time.
1
Check the power supply and voltage of the control circuit; _____V must be ±10% within the range of rated
operating power.
No. Start up the unit

1 Check all the conditions needed to start up the unit: oil temperature, mode, required load etc.

Start up the unit, and observe the operation of compressor, electric expanding valve, fan motor and water
pump etc.
2
Note: the unit will be damaged under abnormal running state. Do not operate the unit in states of high
pressure and high current.
Others:

Estimation or suggestion on the general running situation: good, modify


Identify the potential problem (nothing means the installation and debugging are in accordance
with the requirements.)
a. problem of power supply and electric control system:
b. problem of load calculation:
c. outdoor refrigerant system:
Items for d. noise problem:
acceptance after e. problem of indoor and piping system:
debugging h. other problems:
During operation, it is needed to charge for the maintenance due to non-quality problems such as
incorrect installation and maintenance.
Acceptance

Is the user trained as required? Please sign. Yes( ) No( )

21. Daily Operation and Maintenance


In order to avoid damage of the unit, all protecting devices in the unit had been set before delivery, so please do
not adjust or remove them.
For the first startup of the unit or next startup of unit after long-period stop (above 1 day) by cutting off the power,
please electrify the unit in advance to preheat the unit for more than 8 hours.
Never put sundries on the unit and accessories. Keep dry, clean and ventilated around the unit.
Remove the dust accumulated on the condenser fin timely to ensure performance of the unit and to avoid stop
of the unit for protection.
In order to avoid protection or damage of the unit caused by blockage of the water system, clean the filter in
water system periodically and frequently check water replenishing device.
In order to ensure anti-freezing protection, never cut off the power if ambient temperature is below zero in winter.
In order to avoid frost crack of the unit, water in the unit and pipeline system not used for a long period should
be drained. In addition, open the end cap of the water tank for drainage.
When the water tank has been installed but the water tank is set to “Without”, functions relative with the water
tank will not work and the displayed water tank temperature will always be “-30”. In this case, the water tank would
suffer frostbite and even other severe influences under low temperature. Therefore, once the water tank has been
installed, the water tank must be set to ‘’With”, otherwise GREE will not be responsible for this abnormal operation.
Never frequently make the unit on/off and close the manual valve of the water system during operation of the
unit by users.
Ensure frequent check to the working condition of each part to see if there is oil stain at pipeline joint and charge
valve to avoid leakage of refrigerant.
If malfunction of the unit is out of control of users, please timely contact with authorized service center.
The water pressure gage is installed in the returning water line in the unit. Please adjust the hydraulics system

55
Air-to-water Heat Pump Split Versati SPLIT TYPE

pressure according to next item:


(1) If the pressure is less than 0.5 bar, please recharge the water immediately;
(2) When recharging, the hydraulics system pressure should be not more than 2.5 Bar.
Troubleshooting
Malfunctions Reasons Troubleshooting
① Power supply has problem. ① Phase sequence is reverse.
Compressor does not ② Connection wire is loose. ② Check out and re-fix.
start up ③ Malfunction of mainboard. ③ Find out the reasons and repair.
④ Malfunction of compressor. ④ Replace compressor.
① Fixing bolt of fan is loose. ① Re-fix fixing bolt of fan.
Heavy noise of fan ② Fan blade touches shell or grill. ② Find out the reasons and adjust.
③ Operation of fan is unreliable. ③ Replace fan.

① Liquid slugging happens when liquid ① Check if expansion valve is failure and
Heavy noise of
refrigerant enters into compressor. temp. sensor is loose. If that, repair it.
compressor ② Internal parts in compressor are broken. ② Replace compressor.

Water pump does not


① Malfunction of power supply or terminal. ① Find out the reasons and repair.
② Malfunction of relay. ② Replace relay.
run or runs abnormally ③ There is air in water pipe. ③ Evacuate.

① Discharge or add part of refrigerant.


② Water system is blocked or there is
① Poor or excess refrigerant.
Compressor starts or air in it. Check water pump, valve and
② Poor circulation of water system.
stops frequently pipeline. Clean water filter or evacuate.
③ Low load.
③ Adjust the load or add
accumulating devices.

The unit does not heat ① Repair by leakage detection and add
① Leakage of refrigerant.
although compressor refrigerant.
② Malfunction of compressor.
is running ② Replace compressor.

① Enhance heat insulation efficiency of


① Poor heat insulation of water system. the system.
Poor efficiency of hot ② Poor heat exchange of evaporator. ② Check if air in or out of unit is normal
water heating ③ Poor refrigerant of unit. and clean evaporator of the unit.
④ Blockage of heat exchanger at water side. ③ Check if refrigerant of unit leaks.
④ Clean or replace heat exchanger.

56
GREE ELECTRIC APPLIANCES, INC. OF ZHUHAI
Add: West Jinji Rd, Qianshan, Zhuhai,Guangdong, China, 519070
Tel: (+86-756) 8522218
Fax: (+86-756) 8669426
E-mail: gree@gree.com.cn www.gree.com