VR300TK/B 300 * * * * F7 * * 184

VX E 700 * * * F7 * * 185

VX EV 700 * * * F7 * * 185
VR-E
VR 300 TK/B
VR EV 700 * * * * F7 * * 184

VR E 700 * * * * F7 * * 184

TLP 1600 * * * G4 * 186

TA 4500 * * * F5 * * * 187
VX-E VR-DC
TA Big 15000 * * F5 * * 189

VR-DC 700 * * * * F7 * * * 184

VR-DCV 700 * * * * F7 * * * 184

F 3000 Opt * * EU3 Opt Opt 191


VX-EV TLP
K 12000 Opt * * EU3 Opt Opt 192

Maxi 2000 * * * F7 * * Opt * 193

Topvex FR 6552 * * * * F7 * * Opt * 45

TA
VR-EV

Maxi F - AHU K - AHU

179
Air Handling Units
K-FanOverview
AHU EC
• Compact design • Heat recovery efficiencies up to 90%
• Easy to install • Automatic defrost functions
• Including heating and filter • Large front covers for easy maintenance
• Maintenance-free and reliable fan motors
• Cross flow heat exchanger
• Rotating heat exchanger
- automatic change normal/summer operation
- flexible installation without conden­sation drain

VR-DCV/DC

VR DCV and DC are com-


TLP plete air handling units
suitable for homes, smaller
offices and similar premises.
TLP Compact supply air unit for circular ducting with With EC-fan motors and a
built in speed controllable fan. Housing made of new regulation system the
galvanized sheet metal with a 50 mm acoustic energy use is optimized to
insulation. Circular electrical heater and G3 filter be able to meet the new
included. Heater is controlled by a pulser with room regulations on energy
temperature or duct sensor (not included). Max air flow management. To ensure optimal
1350 m3/h. operation, the rotating heat exchanger, supply and extract
air filter, supply and extract fans, all temperature sensors and
the re-heater are monitored.
DCV(/B) units are designed for installation on wall, in laun-
dry rooms, utility rooms or similar. With the white painted
door and side panels the unit can easily be
installed to blend in with the surroundings. Large
inspection doors simplifies inspection and service. The VR
400 DCV/B has a by-pass function which allows the unit to
be connected to a kitchen hood. The polluted air from the
hood is led directly to the extract fan without coming in
TA contact with the rotating heat exchanger.
The DC-units are designed for mounting horizontal on the
wall. They are manufactured with 50 mm insulation and are
TA Compact supply air unit for circular/rectangular therefore suitable to be installed in cold premises e.g. store
ducting suitable for supplying air to smaller build- rooms, attics or similar. Max air flow 550 m3/h.
ings. The Plug & Play unit is powered by a single inlet
centrifugal fan. Electrical or hot water heating battery VX-EV/E
and a F5 filter is included. Housing made from gal-
vanized sheet metal with 50 mm acoustic insulation.
Control unit for fan speed and heater is included
with the unit. Max airflow 14 000 m3/h (size 6000-14
000 available in June-10). Accessories:
Supply air damper, cooling battery.

The VX range is a complete air handling unit suitable for


ventilating homes, offices and smaller areas in commercial
buildings. The cross flow heat exchanger are mostly used
when there is a strong need to minimize the mixing of sup-
ply and extract air.
9 The unit has an automatic defrost function of the cross
flow heat exchanger. The EV model is suitable for wall
mounting and the E model for lying on the side. The E
model can also be mounted in cold areas due to the
50 mm of casing insulation. The unit is very easy to
operate with the external control panel.
Max air flow 550 m3/h.

180
Air Handling Units
K-Fan EC AHU Overview
VR 300 ECV/B
Topvex TR/TX
The VR 300 ECV/B is a very compact unit for
ventilation of homes and Topvex TR/TX is a “Plug and
primarily developed for wall play” air handling unit with a
mounted installation but can be modern design intended for
installed horizontally e.g. in a ventilating offices, day-care
false ceiling. The unit is double centres or used as zone ven-
skinned, fully tilation in larger buildings e.g.
insulated, equipped EC-fan schools. Top-connection of the
motors for supply/extract air, air-ducts minimize the “Foot-
rotating heat exchanger, filters print” of the unit. To meet the
and thermostat operated new restricted energy requirements with low SFP (Specific
re-heater battery.   Fan Power) Topvex is equipped with EC fan motors. EC-mo-
VR 300 ECV/B is equipped with large inspection tors consume an average of 30% less energy than AC mo-
hatches on both sides and is by that means tors. In some applications, the saving can be 50% or more.
reversible for optimal and simple duct connections. Topvex TR is equipped with a high efficiency rotating heat
Max air flow 180 m3/h. exchanger with an efficiency of up to 85%. Rotating heat
exchangers do not need condense water drainage and is
therefore very flexible to install.
Topvex FR Topvex TX with its crossflow heat exchanger is normally
used where it is a requirement that the supply and exhaust
Topvex FR03-11 is a air must be kept separated. The units have an efficient
series of efficient de-icing function.
ventilation units de-
signed for offices, shops,
schools, daycare centre
or similar premises. The
units can be installed
flat on the floor or sus-
pended in a false ceiling.
The units are especially
designed to meet the coming energy requirements and
have therefore a very low energy use and high efficiency
rotating heat exchangers. To simplify the installation and
commissioning, the units are included with control sys- DV
tem and pre-configured. The unique design with double
rotating heat exchangers makes the unit very flat. No
need of condense-water drainage makes the unit very
flexible to install. Max air flow 4000 m3/h. NB
The DV and NB, air handling units (AHU) are highly flexible
AHU’s that can be configured to make up the heart of any
Topvex SR/SX mechanical ventilation system.
Topvex SR/SX is a “Plug and play” air handling unit The DV comes in a range of 12 different sizes with air
with a modern design volume capacities from 1500 m3/h to 54 000 m3/h, making it
intended for ventilating possible to always find the unit suitable for any requirement.
offices, day-care centres The NB comes in a range of 15 different sizes with air
or used as zone ventila- volume capacities from 500 m3/h to 87 000 m3/h.
tion in larger buildings Both DV and NB can be configured as supply units or as
e.g. schools. To meet the a supply – exhaust units with heat exchanger, either Rotary
new restricted energy Heat Exchanger, Plate Heat Exchanger or Run-around Coil
requirements with low Heat Exchangers.
SFP (Specific Fan Power).
Topvex is equipped with
EC fan motors. EC-motors consume an average of 30%
less energy than AC
motors. In some applications, the saving can be 50% TIME
or more. Topvex SR is equipped with a high efficiency
rotating heat exchanger with an efficiency of up to 85%.
Rotating heat exchangers do not need
9
condense water drainage and is therefore very flexible The DV - TIME unit is available in 6 sizes and comes
to install. Topvex SX with its crossflow heat exchanger complete with pre-wired controls package.
is normally used where it is a requirement that the sup- Air Volumes from 1440 m3/h to 14 400 m3/h
ply and exhaust air must be kept separated. The units Suitable for internal & external mounting.
have an efficient de-icing function.

181
Air Handling Units
K-Fan EC Unit
Compact

Air Handling Units - Overview


Systemair has a wide range of air handling units for use in various applications from small office premises to larger
Industrial use. Common to all items in the range is that systems and components have been developed to satisfy
stringent demands for low energy consumption. Heat exchangers, motors and fan units have all undergone extensive testing,
both in the laboratory and out in the field, in order to comply with current and future demands for low energy consump-
tion. All products are also manufactured to comply with environmental requirements. To ensure easy
installation, many of these units feature control systems enabled for plug-and-play , i.e simple start-up.

TA 0.07-1.25 m3 /s
200 500 1000 1500 2000 4000 6000
m3/h
4500

Supply air handling units intended for


3000
small to medium-sized premises.
Available in 7 sizes and supplied 2000

complete with control system, fan,


1500
heating coil and filter.
A separate extract fan can be linked into 1100

the control for Supply & Extract 650


Ventilation. LPHW & Elec Heater
Batteries available. 450
m3/s
0.05 0.1 0.2 0.3 0.4 0.5 1 2

F 0.13-0.97 m3 /s
500 1000 1500 2000 3000
m3/h
035
False ceiling units for small and medium-
sized premises. Available in 3 sizes and in 030
3 versions.
016

m3/s
0.1 0.2 0.3 0.4 0.5 1 1.4

Maxi 0.1-0.56 m3 /s
500 1000 1500 2000 3000
m3/h

Compact air handling units with a low overall 2000

height and heat recovery, intended for small 1100


and medium-sized premises. Available in 2
m3/s
sizes and supplied complete with control
0.08 0.1 0.2 0.3 0.4 0.5 1
system. Also available with an electric or hot
water heating coil.

Topvex FR 0.15-1.78 m3 /s

Compact air handling units with a low overall


height and heat recovery, intended for small
and medium-sized premises. Available in 4
9 sizes and supplied complete with control
system. Also available with an electric or hot
water heating coil. Efficiencies up to 90%

182
Air Handling Units
K-Fan EC Compact & Modular Units

200 500 1000 1500 2000 4000 6000


m3/h
Topvex TR/TX 0.09-1.9 m /s 3

Topvex TR (rotating heat exchanger) 15

Topvex TX (cross-flow heat exchanger) Compact air handling units with top
12
connection and rotating or cross-flow heat
09 exchangers, intended for medium-sized
premises. Supplied complete with control
06
system. Equipped with EC motors and can
04 be supplied with an electric or hot water
heating coil.
03
m3/s
0.05 0.1 0.2 0.3 0.4 0.5 1 2

200 500 1000 1500 2000 4000 6000


m3/h
Topvex SR/SX 0.1-1.9 m /s 3

Topvex SR (rotating heat exchanger) 11


Compact air handling units with side
Topvex SX (cross-flow heat exchanger) 09
connection and rotating or cross-flow heat
07 exchangers, intended for medium-sized
premises. Supplied complete with control
06
system. Equipped with EC motors and can
04 be supplied with an electric or hot water
heating coil.
03
m3/s
0.05 0.1 0.2 0.3 0.4 0.5 1 2

1500 2000 4000 6000 10 000 15 000


m3/h
TIME 0.4-4.0 m3 /s
40

30 Compact air handling units with heat


25 recovery, intended for medium-sized
20 premises. Available in 6 sizes and
15 supplied complete with control system.
10
Also available with heating coil and
m3/s cooling coil.
0.3 0.4 0.5 1 2 3 4 5

1500 2000 3000 5000 10 000 20 000 30 000 50 000 90 000


240 m3/h

DV
190

120
150 0.4-24 m3 /s
100
80
60
Modular air handling units intended for
50 large premises. Available in 14 sizes.
40

20
25
30 Large number of combinations and
options. 9
15
10 m3/s Systemair CAD selection programme
0.4 0.7 1 2 3 5 10 15 20 25 can be downloaded from our website.

183
Air Handling Units
K-Fan
VR Heat
ECRecovery Units (Suitable for Residential Applications)
VR-EV/B & VR-EV
VR-EV/B and -EV is a complete air handling unit suitable for ventilating homes, offices
and smaller areas in commercial buildings. With the white painted inspection door and
the additional white painted side covers the unit is design to be mounted on the wall
into e.g.; a laundry room. The rotating heat exchanger have the effciency of up to 85%
and have the advantages that there is now water condensation and thereby no need
of condensation drainage. The EV/B model has the advantage that it also can be con-
nected to a cooker hood by using the integrated by-pass duct where the polluted air
is lead direct to the extract fan.

VR-E
VR-E is a complete air handling unit suitable for ventilating homes, offices and smaller areas
in commercial buildings.VR-E is designed to be mounted lying in the e.g. attic. The unit have
double sheet metal casing with intermediate 50mm insulation and is therefore
suitable to be mounted in cold places. To simplify the maintenance and make the
installation more flexible the VR-E is equipped with large inspection doors on both of the sides.
All components can be removed from each side.VR-E have a rotating heat exchanger and
thereby the same advantages as for the VR-EV units.

VR 300TK/B
The VR 300 TK/B is a compact unit for ventilation of homes and primarily developed for wall mounted
installation but can be installed horizontally e.g. in a false ceiling. The unit is double skinned, fully
insulated, equipped with centrifugal fans for supply/extract air, rotating heat exchanger, filters and ther-
mostat operated re-heater battery.VR 300 TK/B is quipped with large inspection hatches on both sides
and is by that means reversible for optimal and simple duct connections.

VR DC/DCV (SAP Appendix Q Rated)


VR 400/700 DCV and DC are complete air handling units suitable for homes, smaller offices and
similar premises. With EC-fan motors and a new regulation system the energy use is optimized
to be able to meet the new regulations on energy management. Compared to AC-motors
EC-motors maintain efficiency throughout the motor speed range when speed controlled and
are therefore suitable to use in demand controlled ventilation units. Measurements show that an
EC-motor reduces the energy use with up to 50% compared to a traditional voltage
controlled AC-motor.

VR Length Spigot Height Depth VR Width Spigot Height Depth VR Width Spigot Height Depth
250 EH/B 1071 ø125 273 540 300 TK/B 598 ø125 630 327 400 DC 1149 ø160 576 449
400 E 1149 ø160 576 449 400 EV/B 796 ø160 800 406 700 DC 1149 ø200 576 545
700 E 1149 ø200 576 539 700 EV 918 ø200 872 509 400 DCV/B 796 ø160 800 406
700 DCV 918 ø200 872 509

VR 400 DCV/B
VR 400 DC
2,5 VR 700 DCV
2,5
VR 700 DC
2,5
2,5

2,0
2,0
2,0

1,5 2,0
1,5 1,5
1,5

3,0 = SFP value (Specific Fan Power)

3.0 = SFP value (Specific Fan Power)

Technical Data 250EH/B 400E 700E 300TK/B 400EV/B 700EV 400DC 700DC 400DCV/B 700DCV
VR

9 Voltage/Frequency
Power, motors
V/50 Hz
W
230 ~
2x127
230 ~
2x138
230 ~
2x315
230-240 ~
2x138
230-240 ~
2x138
220 ~
2x285
230 ~
2x115
230 ~
2x246
230 ~
2x114
230 ~
2x240
Power, re-heater kW 500 1670 1670 1000 1670 1670 1670 1670 1670 1670
Fuse A 10 10 16 10 10 16 10 13 10 13
Weight kg 40 57 70 45 62 80 55.5 66.4 57 72.3
Filter, fresh air bag F7 F7 F7 F7 F7 F7 F7 F7 F7 F7
Filter, extract air bag G3 G3 G3 G3 G3 G3 G3 G3 G3 G3

184
Air Handling Units
K-Fan ECVX Heat Recovery units (Suitable for Residential Applications)
VX 250 TV/P
The VX 250 TV/P is a compact unit for ventilation of apartments. The unit is designed to be
mounted on the wall in a laundry room or similar. The unit is equipped with centrifugal fans
for supply/extract air, cross flow heat exchanger, filters and thermostat operated re-heater
battery.VX 250 TV/P is quipped with a large inspection door to simplify the maintenance.

VX-E, -EV
The VX range is a complete air handling unit suitable for ventilating homes, offices and
smaller areas in commercial buildings. The cross flow heat exchanger are mostly used when
there is a strong need to minimize the mixing of supply and extract air.
The unit have an automatic defrost function of the cross flow heat exchanger.
The EV-model is suitable for wall mounting and the E-model for lying on the side.
The E-model can also be mounted in cold areas due to the 50mm of casing insulation. The
unit is very easy to operate with the external control panel.

TF Fresh Air filter


AF Extract Air Filter Explanatory Diagram
FV Exhaust Fan
TV Supply Fan
FT Defrosting Thermostat
VV Heat Exchanger
VB Elec Heater Battery
OT Overheat Thermostat
BT Emergency Thermostat
L Condensate drain
AT Setting of supply air temperature

VX Width Spigot Height Depth


250 TV/P 600 ø125 600 295
400 EV 919 ø160 884 327
700 EV 918 ø200 899 507
VX Length Spigot Height Depth
400 E 1189 ø160 650 327
700 E 1189 ø200 651 500

VX 250TV/P 400EV 700EV 400E 700E


Voltage/Frequency V/50 Hz 230-240~ 230~ 230~ 230~ 230~
Input power, motors W 2 x 115 2 x 138 2 x 315 2 x 152 2 x 308
Input power, re-heater battery
Mains fuse
W
A
1000
10
1670
10
2670
16
1670
10
2670
16
9
Weight kg 30 55 75 48 67
Filter, supply air F5 F7 F7 F7 F7
Filter, extract air Aluminium Aluminium Aluminium Aluminium Aluminium

185
Air Handling Units
K-Fan- Supply
TLP EC Air Handling Unit
• Supply air units
• Filter, Elec Heater & Fan
• Acoustic Casing 50mm Insulation
• Speed-controllable

A compact unit consisting of a fan and heater in galvanised sheet steel, and an EU4 filter.
The casing is insulated inside with 50 mm of mineral wool. Rubber sealed sleeve couplings.
Neoprene sealing strips and toggle locks.
Note that the fan must always be connected to 230 V. Fan run-on is not normally required.
(Lowest air velocity 1.5 m/s). Max output air temperature 40°C. The fan may be adjusted by
either a transformer or a thyristor. The heating element is most effectively controlled by a power regulator, pulser and duct
sensor. The filter should be checked regularly and replaced at least twice a year.

1
2
3

1 2 3 TLPW315

TLP 125/1.2 160/2.1 315/9.0 TLPW315


Voltage/Frequency V/50 Hz 230 230 400 230
Phase ~ 1 1 3 1
Input, power el heating battery kW 1.2 2.1 9.0 Enq
Current, el heating battery A 5.22 9.13 13 n/a
Max temp transported air °C 70 70 40 40
Temp control Pulser Pulser TTC 2000 AQUA
Min air flow m3/h 70 110 415 180
Sound pressure level at 3 m dB(A) 29.3 38.9 49.5 33
Connection duct ø mm 125 160 315 315
Weight kg 31 33 54 75

Fan type K 125M K 160M KD 315L TLPW315


Voltage/Frequency V/50 Hz 230 230 230 230
Phase ~ 1 1 1 1
Power W 29 61 372 643
Current A 0.17 0.27 1.62 2.82
R.p.m. min-1 2483 2499 2595 1440
Speed control, five step Transformer RE 1.5 RE 1.5 RE 3 RTRE3
Speed control, high/low Transformer REU 1.5 REU 1.5 REU 3 REU3.0
Speed control, stepless Thyristor REE 1 REE 1 REE 2 STL3.0

9 TLP Length Spigot Width Height


125/1.2 786 ø125 459 436
160/2.1 786 ø160 459 436
315/9.0 948 ø315 549 551
315/LPHW 983 ø315 546 585

186
Air Handling Units
K-Fan EC TA - Supply Air Handling Unit c/w Controls
• Supply air units with either LPHW or Elec Heating
• Low overall height for ceiling void mounting
• Complete with integrated control system
• Speed-controllable
• Remote Extract fan can be linked to controller
• Weather cover available for external mounting

TA is a series of air-handling units designed for ventilating petrol stations,


schools, shops, offices and other smaller premises. The units have low overall
height and are easy to install in existing premises.
The units are delivered complete with control system, heating battery and
filters. The TA EL has an electric re-heater, whilst the TA HW uses a hot-water
battery for re-heating. Speed-controllable, high efficiency plug fans make service and
cleaning easy.
The double skin casing is insulated with 50 mm mineral wool to minimize sound to the
environment. The units are controlled from a user-friendly control panel that can be
mounted on the wall.

TA Voltage Motor Heater Airflow m3/s @ Pa Filters


V/50Hz W kW 50Pa 100Pa 200Pa 300Pa 400Pa 500Pa
450EL 230/400 130 3/3 or 6 0.155 0.143 0.11 0.077 0.025 - EU5
650EL 400 220 5 or 8.3 0.22 0.21 0.17 0.15 0.1 0.06 EU5
1100EL 400 325 8 or 13.3 0.34 0.32 0.27 0.23 0.19 0.14 EU5
1500EL 400 548 12 or 20.3 0.49 0.47 0.42 0.37 0.31 0.25 EU5
1500HW 230 573 enq 0.41 0.4 0.35 0.3 0.25 0.2 EU5
2000EL 400 705 16 or 33.3 0.6 0.57 0.54 0.49 0.44 0.39 EU5
2000HW 400 673 enq 0.56 0.54 0.5 0.46 0.42 0.36 EU5
3000HW 400 1084 enq 0.95 0.9 0.8 0.64 0.4 0.1 EU5
4500HW 400 1880 enq 1.44 1.39 1.27 1.12 0.9 0.6 EU5

TA-450EL, 650EL, 1100EL, 1500EL, 1500HW


qv [m3/h]
0 200 400 600 800 1000 1200 1400 1600 1800
Ps [Pa]

300
TA
TA

TA

TA

250
15
45

11
650

00
0
0E

0
EL

EL
EL
L

200
/H
W

150

100

50

0
0 0,1 0,2 0,3 0,4 0,5
qv [m3/s]

TA-2000EL, 2000HW, 3000HW, 4500HW


qv [m3/h]
2000 3000 4000 5000
Ps [Pa]

300
TA TA
TA 2

TA 2

30 45
250 00 00
0
0

HW HW
00 E
00 H

9
200
L
W

150

100

50

0
0,4 0,6 0,8 1,0 1,2 1,4 1,6
qv [m3/s]

187
Air Handling Units
K-Fan
TA Supply
EC Air Handling Units

TA Unit A B C D E F G H I J K L Dia dy N Weight


kg
450EL 1125 500 354 200 dia - 51 - 1042 89 - - - - 176 50
650EL 1203 556 307 200 dia 69 - 1116 82 - - - - 702 55
1100EL 1233 620 374 250 dia 75 - 1146 140 - - - - 731 67
1500EL 1190 750 374 200 400 105 175 1146 69 - - - - 731 82
1500HW 1190 750 374 200 400 105 175 1146 175 102 125 162 21mm 731 71
2000EL 1190 850 374 250 500 73 175 1146 73 - - - - 731 99
2000HW 1190 850 374 250 500 73 175 1146 175 101 92 212 21mm 731 87
3000HW 1296 904 545 300 600 141 152 1252 152 92 160 262 27mm 325 125
4500HW 1346 1006 545 400 700 91 153 1302 153 92 110 362 34mm 320 145

Suitable Extract Fans External extract Fan


(See table for options)
TA Unit Current Current In-line duct In-line duct In-line duct Roof Roof
An extract fan can be connected to the unit
Amps Amps fan fan fan mounted mounted
and be operated in parallel with the TA supply
230V 400V
unit. The extract fan must be 1-phase for TA
TA-450 0.7 - K200M KVK160L KVKE200 DVS225EZ DHS225EZ units 450 - 1500 and 3-phase for TA units 2000
TA-650 1.0 - K200L KVK200 KVKE200 DVS225EZ DHS225EZ & above.
The extract fan must also have integrated ther-
TA-1100 3.5 - KD250M KVK250L KVKE315M DVS311EV DHS311EV
mal contacts for protection against over heating.
TA-1500 2.6 - KD250L RS40-20L KVKE315L DVS355E4 DHS355E4
TA-2000 - 2.8 MUB355DV RS60-35M3 RSI60-35M3 DVS355DV DHS355DV
TA-3000 - 2.0 RSI60-35L3 KT60-35-6 KD400M3 DVS400DV DHS400DV
TA-4500 - 4.3 MUB450DV KD400XL3 DVS450DV DHS450DV

Explanatory Diagram
TF Supply Fan
GT1 Supply Air Sensor
SV Actuator & Valve
GTO Overheat Sensor
GTF Frost Protection Sensor
ST1 Fresh Air Damper Actuator

L.P.H.W Water Battery Data Max. operating temp 100°C at 16 bar


TA unit TA-1500 TA-2000 TA-3000 TA-4500
Water Battery Temp. (F&R) 60/40 70/50 80/60 60/40 70/50 80/60 60/40 70/50 80/60 60/40 70/50 80/60
Air flow m3/s 0.38 0.38 0.38 0.52 0.52 0.52 0.85 0.85 0.85 1.33 1.33 1.33
Outdoor temp. 0°C
Supply temp. °C 19.8 25.1 21.5 27.0 20.7 26.0 20.0 25.2
Water flow l/s 0.1 0.1 0.2 0.2 0.3 0.3 0.4 0.5

9 Pressure drop
Capacity
kPa
kW
2.9
9.2
4.3
11.6
2.6
13.6
3.8
17.1
2.7
21.4
4.0
27.0
2.2
32.4
3.3
41.0
Outdoor temp. -10°C
Supply temp. °C 14.7 20.0 25.2 16.6 22.1 27.6 15.6 20.9 26.2 14.8 20.1 25.3
Water flow l/s 0.1 0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.4 0.5 0.6 0.7
Pressure drop kPa 4.3 5.9 7.7 3.8 5.1 6.6 4.0 5.4 7.0 3.3 4.5 5.9
Capacity kW 11.4 13.9 16.3 16.9 20.4 23.8 26.5 32.1 37.6 40.3 48.8 57.4

188
Air Handling Units
K-Fan EC TA Big - Supply AHU (LPHW & Controls)
• Supply AHU with Controls
• Duties from 0.8 to 4.40 m3 /s
• Available in 5 casing sizes
• Compact Design
• Bag Filter, LPHW Coil & Fan
• Accessories available
• Low Breakout noise 50mm Insulation
• Pentapost Double Skin Construction
• Can be mounted externally (Roof Required)

TA is a series of efficient ventilation units designed for schools, shops and offices, etc.
The units are complete with controls and are delivered ready for operation.
TA units are delivered pre-programmed, tested and ready for installation. Connect the unit to the duct system, (connect any
external components), connect the mains power, set the timer and fan speed in the controller and the unit is installed.
General
TA units are delivered enclosed in plastic and mounted on pallets. The units are fully wired internally.
The controller is preset and has been test-run at the factory. Cables for external components
(outdoor air dampers, etc.) are connected to terminals in the electrical connection box. The same applies to the valve
actuator for the heating coil.
Measurement and control accuracy
The supply air sensor, operates with an accuracy of +/-0.4K. The accuracy of the controlled temperature is the same.
Unit housing
The unit housing and doors are made of galvanised sheet steel with 50 mm mineral wool insulation for low noise to the
surroundings. The TA units have large doors that make inspection and maintenance easy. The doors are lockable.
The electrical connections are collected in one place to make it easy for the installer.
The controls display is connected with a 10 m cable (included)

TA Big Unit Voltage Fuse Motor L P H W A B C D E F G H We i g h t


V A kW Coil kW kg
6000 HW 400-3-50 3x16 1.9 Enq 1720 1120 595 750 400 600 260 60 291
7000 HW 400-3-50 3x16 2.5 Enq 1720 1270 670 750 400 800 235 85 335
9000 HW 400-3-50 3x20 3.3 Enq 1870 1420 745 900 500 900 260 85 387
11000 HW 400-3-50 3x25 3.6 Enq 1870 1570 820 900 600 1100 235 60 449
14000 HW 400-3-50 3x32 5.1 Enq 2020 1720 895 1050 600 1200 260 110 521
Full selections can be found on our website www.systemair.co.uk

189
Air Handling Units
K-Fan
TA BigEC
- Performance Curves

190
Air Handling Units
K-Fan EC F - Air Handling Unit
• Low Profile AHU’s for ceiling void mounting
• Duties from 0.13 to 0.97 m3 /s
• Available in 3 casing sizes

• 3 sizes (from approx. 500 m³/h up to approx. 3.500 m³/h)


• Modular system, corrosion resistant aluminium profile with plastic corners
• 20 mm double skinned panels, manufactured from steel sheet with non-flammable
mineral wool infill for thermal and acoustic insulation
• Variety of components (filter, heating, cooling, heat recovery.)
• Wide unit range: supply, exhaust, combined with/without heat recovery

F AHU’s F16 CB-23 F30 CH-23


Voltage/Frequency V/50 Hz 230 230
Input power, motors W 1150 1750
Input power, LPHW heater battery kW 14.0 24.0
Max Airflow m3/s 0.50 0.69
Fan Section Direct Drive GT1 280E4 GC1 356E4
Speed R.p.m 1210 1160
Current A 5.1 7.6
Sound Pressure level @ 3m dB(A) 62 69
Weight kg 97 118
Filter, Supply Bag EU5 EU5

Heat Recovery

Supply Units

Extract Units
Sound power (Lw) dB(A)

F16 CB-23 Mid frequency band

63 125 250 500 1k 2k 4k 8k

LwA Inlet 62 65 67 70 76 74 72 67

LwA Outlet 64 67 69 72 78 76 74 69

LwA Surrounding 42 52 53 56 62 60 58 53

Measuring point: qv = 0.38m3/s @ 200Pa

Sound power (Lw) dB(A)


9
F30 CH-23 Mid frequency band

63 125 250 500 1k 2k 4k 8k

LwA Inlet 71 73 76 77 80 79 77 72

LwA Outlet 72 75 78 79 82 81 79 74

LwA Surrounding 45 54 56 59 65 63 61 56

3
Measuring point: qv = 0.40m /s @ 450Pa

191
Air Handling Units
K - Air Handling Unit
• Modular AHU’s for internal or External mounting
• Duties from 0.2 to 4.0 m3 /s
• Available in 5 casing sizes

• 5 sizes (from approx. 500 m³/h up to approx. 15.000 m³/h)


• Modular system, corrosion resistant aluminium profile with
aluminium corners or plastic corners
• 20 mm double skinned panels, manufactured from steel sheet with non-
flammable mineral wool infill for thermal and acoustic insulation
• Variety of components (filter, heating, cooling, heat recovery,...)
• Wide unit range: supply, exhaust, combined with/without heat recovery

K AHU’s F25 CC-23 F42 CG-23 K62 CK-23


Voltage/Frequency V/50 Hz 230 400 400
Input power, motors W 1050 2800 5900
Input power, LPHW heater battery kW 12.0 32.0 39.0
Max Airflow m3/s 0.36 1.14 1.39
Fan Section Direct Drive GC2 249E4 GC2 283D4 GC2 399D4-A
Speed R.p.m 1180 1240 1120
Current A 4.6 4.60 9.30
Sound Pressure level @ 3m dB(A) 60 65 72
Weight kg 89 136 194
Filter, Supply Bag EU5 EU5 EU5

Heat Recovery

Supply Units

Extract Units

192
Air Handling Units
K-Fan EC Maxi - Heat Recovery Unit
• Complete with integrated control system
• Low overall height
• Easy to service
• EU7 fine filter
• Available with LPHW or Elec Htg
• External Roof Cover (Option)

The MAXI unit are designed for the ventilation of smaller offices, shops or similar premises. The unit is to be installed
horizontally in the attic, above a corridor or similar locations. The EL (Elec heating unit) can also be installed upside down.
The MAXI 1100 is manufactured from galvanised sheet steel with 50 mm insulation (30 mm for the inspection covers.)
The 2 inspection covers with quick-release fasteners together with removable motors and heat exchange unit facilitate
easy service and maintenance.
The MAXI 2000 unit is supplied in 2 parts to facilitate easy installation. The MAXI 2000 is manufactured from galvanised
sheet steel, double skinned, with 50 mm of Rock-Wool insulation. To facilitate easy maintenance, the access covers are
fitted with quick release clips. In addition, the motors and heat exchanger re removable.
The heat recovery efficiency is approximately 55-70%.
The MAXI EL has an electric re-heater, whilst the MAXI HW uses a hot-water battery for re-heating.
A by-pass channel with motorized damper is built into the MAXI 1100 unit and is an optional extra on the MAXI 2000
unit.
The integral transformer has a 7-step choice on the MAXI 1100 for fan speed and five-step choices on the MAXI 2000.
The SCP control panel has an integral 7-day timer for selecting day and night operating settings.
MAXI Voltage Motor Main Fuse Heater Airflow Airflow m3/s @ Pa Filters Weight
V/50Hz W Amps kW 50Pa 100Pa 150Pa 200Pa 250Pa 300Pa 350Pa kg

MAXI 1100EL 400 2x492 16 5 Supply 0.37 0.35 0.32 0.27 0.21 0.1 - EU7 172
Extract 0.33 0.30 0.26 0.22 0.14 0.05 -
MAXI 1100HW 230 2x492 10 6.2 - 7.5 Supply 0.37 0.35 0.32 0.27 0.21 0.1 - EU7 169
Extract 0.33 0.30 0.26 0.22 0.14 0.05 -
MAXI 2000EL 400 2x1119 25 9 Supply 0.63 0.60 0.58 0.56 0.53 0.5 0.45 EU7 232
Extract 0.60 0.58 0.55 0.53 0.50 0.47 0.43
MAXI 2000HW 400 2x1119 10 10.9 - 17.0 Supply 0.63 0.60 0.58 0.56 0.53 0.5 0.45 EU7 232
Extract 0.60 0.58 0.55 0.53 0.50 0.47 0.43

Sound power (Lw) dB(A) Sound power (Lw) dB(A)

MAXI 1100 Mid frequency band MAXI 2000 Mid frequency band

63 125 250 500 1k 2k 4k 8k Tot 63 125 250 500 1k 2k 4k 8k Tot

LwA Suppy Outlet 63 64 68 68 69 65 63 56 75 LwA Suppy Outlet 66 71 75 74 77 70 68 61 82

LwA Extract Inlet 44 53 47 50 42 40 39 34 56 LwA Extract Inlet 64 73 75 75 80 71 69 62 83

LwA Surrounding 45 51 50 39 42 35 27 21 53 LwA Surrounding 40 51 56 49 56 53 51 47 61

3 3 3 3
Measuring point: qv Suppy = 0.21m /s / Extract = 0.18m /s Max. 230V Measuring point: qv Suppy = 0.28m /s @ 480Pa / Extract = 0.30m /s @ 454 Pa

Accessories
MAXI 1100 MAXI 2000
Spring return damper EFD 315 EFD 315
Valve actuator for HW model HWRO HWRO
Valve, 2-way TVTA 202 TVTA 452
Valve, 3-way TVTA 203 TVTA 453
By-pass Duct (heat exchanger)
Circ Duct Adapters
Cooling battery, water
Built-in (inc)
-
CWK 315
BP 1500/2000
OKM 1500/2000
CWK315
9
Combi Roof Cowl THM THM
Combi Wall Cowl VGM VGM
Silencer LDC 315 LDC 315
Filter EU7 BFM 1100/7 BFM 2000/7
CO2 Room Sensor CO2RT-DR CO2RT-DR
Room temp sensor TG-R5/PT1000 TG-R5/PT1000
Outdoor sensor (wall mounted) TG-R6/PT1000 TG-R6/PT1000
Exhaust air duct sensor TG-KH/PT1000 TG-KH/PT1000

193
Air Handling Units
K-Fan- EC
Maxi Performance & Dimensions
Supply Air Extract Air Supply Air Extract Air

MAXI 1100
200 200
Purge

Alim entation
Repr
Extract Repr
Extract électrique Air
Fresh Air
Fresh
neuf
Air In Airneuf
In

Supply
Souff l Alim entation Exhaust
Refoul
hydraulique ø1/2''

315

Purge

MAXI 2000
Air neuf Reprise

Purge
Refoul
em ent Souff
lage
Purge

Alimentation Reprise
Air neuf
électrique
Alimentation
hydrauliq
ue ø3/4''

Purge

FF Exhaust air fan


TF Supply air fan
F1 Supply air filter
F2 Exhaust air filter
GT1 Supply air sensor

9
GT2 Outside air sensor
GT3 Exhaust air sensor
GT4 Defrost sensor
GTO1 Overheat/Frost thermostat
GTO2 Emergency thermostat
GP1 Pressure switch - filter
GP2 Pressure switch - filter
GP3 Pressure switch - fan
VVX Heat Exchanger
ST1 By-pass damper & motor (accessory Maxi 2000)
ST2 Damper & motor for heat exchanger
ST3 Supply air damper & motor (EFD accessory)
ST4 Exhaust air damper & motor (EFD accessory)
VB1 Electric Heater Battery (EL Models only)

194