Sunteți pe pagina 1din 1

TEST REPORT -BURNT CLAY BUILDING BRICK

Job No : 335-17156 Test Report No : SGL/2015/335-17156/BRK/63687


Sample No : 63687 Report Date: 15-Oct-15

Client : District Project Engineer, SSA Mission, Vadodara


Project Name : Consultancy service for 3rd party technical supervision, monitoring & quality assurance
of Civil Works in the district of Vadodara under Sarva Shiksha Abhiyan Mission for
the financial year 2015-2016 (Package No. SC-167)
District : Vadodara Taluka : Dabhoi
Name of : Dangikuva Activity : Boys Toilet Block
Village\School
Material Frog Mark on
: Burnt Clay Building Brick : DNR
Description Sample
Date Sample rec. : 08-Oct-15
Dimension Test
I.S 1077 - 1992 (Reaffirmed 2011), Clause 6.0
Requirement as per I.S
For Non-Modular Size Results
1077-1992, Clause-6.2 (b)
Length 4601 4600 + 80 mm
Width 2206 2200 + 40 mm
Height 1419 1400 + 40mm
Compressive Water
Item Lab Absorption Lab Sample
Lab Sample No. Strength Efflorescence
No. Sample No. No.
Kgf/cm2 (%)
1 63687-1 37.23 63687-6 12.98 63687-11 Nil
2 63687-2 41.12 63687-7 11.71 63687-12 Nil
3 63687-3 40.88 63687-8 12.98 63687-13 Nil
4 63687-4 42.19 63687-9 13.64 63687-14 Nil
5 63687-5 39.77 63687-10 10.78 63687-15 Nil
Average 40.24 12.42
Specification Requirement as Nil / Slight /
Minimum 35 Maximum
per I.S 1077 - 1992 2 Moderate /
Kg/cm 20%
(Reaffirmed 2011) Serious

Note Checked by: (Authorized Signatory)


1.This certificate or report may not be published for commercial purpose except in full unless permission for
the publication of an approved abstract has been obtained from ,SAI Geotechnical Lab,Vadodara.
2.This test certificate or report applies only to the samples received in the laboratory.
3.The samples were offered by Client

Page 1 of 1