Sunteți pe pagina 1din 2

Small. Powerful. The perfect fit.

High performance in an
affordable, truly compact design Fast and easy to use

• Reliable and accurate patient results • Results in less than


• Standard barcode reader 60 seconds
• Multiple languages available • Small sample size
• Open-mode one touch operation • Low reagent consumption
• Auto shutdown • Zero daily and weekly
maintenance
• Quiet and lightweight
CELL-DYN® Emerald SPECIFICATIONS
Demographics CELL-DYN Emerald Reagents
• Sequence number
Reagent
• Alphanumeric specimen ID
Description Size and List Number
• Alphanumeric patient ID
• Date & time analyzed CN-Free Diff Lyse 960 mL
• Patient name List No. 09H47-02
• CBC with 3-part differential
Diluent 10 L
• Flagging and Alerts
List No. 09H48-02
Dispersional Data Alert Cleaner 960 mL
• Operator-defined patient limits for high and panic values List No. 09H46-02
• System-defined limits for reportable range and analytical
measurement range
• Suspect parameter flags caused by interfering substances CELL-DYN Emerald Controls
or sample abnormalities and Calibrators
• Suspect parameter flags generated when WBC data indi-
cates possible presence of an abnormal population
CELl-DYN 16 Controls and Calibrators
Standards & Safety Compliance CELl-DYN 16 Calibrator
• UL61010A-1 List No. 99110-01
• CE Mark
CELl-DYN 16 Normal Control 6 x 2.5 mL
• CAN/CSA C22.2 No. 1010.1-92
List No. 02H40-01
• ETL Mark
• IEC 61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-8, 4-11 CELL-DYN 16 Tri-Level Control 12 x 2.5 mL
Technology & Methods • Harmonics emissions List No. 99109-01
• Electronic impedance • EN 55011 and EN 61000 or
• Absorption spectrophotometry CELL-DYN 16 Tri-Level Control 6 x 2.5 mL
• Electronic valves Peripheral Devices List No. 99105-01
• Cyanide-free lyse reagent • Dot Matrix or Inkjet printer
• LCD color touch screen • USB thumb drive
• RS232 and TCP/IP LIS interface • Handheld barcode scanner Main Menu
• USB ports
Physical Dimensions
Throughput • Height 13.8” (35cm)
• Up to 60 samples per hour • Width 9.9” (25cm)
• Depth 13.4” (35cm)
Sample Size • Weight 19.85lbs (9kg) (without on-board reagents)
• 9.8 µL
Parameters
Specimen Data Management
• Search by date or sequence number White Cells Red Cells Platelets
• Flagging for patient limit sets WBC RBC PLT
• Flagging for panic values
LYM # HGB MPV
• 1,500 records with histograms on internal memory
• Up to 60,000 on external USB thumb drive LYM % HCT PDW*
• Flagging for patient limit sets
MID # MCV PCT*
• Programmable patient limits Datalog File
• Programmable report units MID % MCH
• Standard barcode reader (reads code 128, code 39, and GRAN # MCHC
interleaved 2 of 5)
GRAN % RDW
Quality Control
• 6 control files *Clinical significance has not been established for these
• 100 runs per file measurands; therefore, they are not reportable in the U.S.
• Levey-Jennings graphs
• Upload/download control information
• eQC Online peer review program

www.abbottdiagnostics.com
1-800-323-9100
© 2008 Abbott HM7185/R1-10 May Printed in USA