High performance in an affordable, truly compact design Fast and easy to use
• Reliable and accurate patient results • Results in less than
• Standard barcode reader 60 seconds • Multiple languages available • Small sample size • Open-mode one touch operation • Low reagent consumption • Auto shutdown • Zero daily and weekly maintenance • Quiet and lightweight CELL-DYN® Emerald SPECIFICATIONS Demographics CELL-DYN Emerald Reagents • Sequence number Reagent • Alphanumeric specimen ID Description Size and List Number • Alphanumeric patient ID • Date & time analyzed CN-Free Diff Lyse 960 mL • Patient name List No. 09H47-02 • CBC with 3-part differential Diluent 10 L • Flagging and Alerts List No. 09H48-02 Dispersional Data Alert Cleaner 960 mL • Operator-defined patient limits for high and panic values List No. 09H46-02 • System-defined limits for reportable range and analytical measurement range • Suspect parameter flags caused by interfering substances CELL-DYN Emerald Controls or sample abnormalities and Calibrators • Suspect parameter flags generated when WBC data indi- cates possible presence of an abnormal population CELl-DYN 16 Controls and Calibrators Standards & Safety Compliance CELl-DYN 16 Calibrator • UL61010A-1 List No. 99110-01 • CE Mark CELl-DYN 16 Normal Control 6 x 2.5 mL • CAN/CSA C22.2 No. 1010.1-92 List No. 02H40-01 • ETL Mark • IEC 61000-3-2, 3-3, 4-2, 4-3, 4-4, 4-5, 4-6, 4-8, 4-11 CELL-DYN 16 Tri-Level Control 12 x 2.5 mL Technology & Methods • Harmonics emissions List No. 99109-01 • Electronic impedance • EN 55011 and EN 61000 or • Absorption spectrophotometry CELL-DYN 16 Tri-Level Control 6 x 2.5 mL • Electronic valves Peripheral Devices List No. 99105-01 • Cyanide-free lyse reagent • Dot Matrix or Inkjet printer • LCD color touch screen • USB thumb drive • RS232 and TCP/IP LIS interface • Handheld barcode scanner Main Menu • USB ports Physical Dimensions Throughput • Height 13.8” (35cm) • Up to 60 samples per hour • Width 9.9” (25cm) • Depth 13.4” (35cm) Sample Size • Weight 19.85lbs (9kg) (without on-board reagents) • 9.8 µL Parameters Specimen Data Management • Search by date or sequence number White Cells Red Cells Platelets • Flagging for patient limit sets WBC RBC PLT • Flagging for panic values LYM # HGB MPV • 1,500 records with histograms on internal memory • Up to 60,000 on external USB thumb drive LYM % HCT PDW* • Flagging for patient limit sets MID # MCV PCT* • Programmable patient limits Datalog File • Programmable report units MID % MCH • Standard barcode reader (reads code 128, code 39, and GRAN # MCHC interleaved 2 of 5) GRAN % RDW Quality Control • 6 control files *Clinical significance has not been established for these • 100 runs per file measurands; therefore, they are not reportable in the U.S. • Levey-Jennings graphs • Upload/download control information • eQC Online peer review program