High performance
Advanced motor TeSys™ T covers all load monitoring and protection needs, from feeders to

management and critical process automation. Your equipment is protected, while advanced
diagnostics, statistics, and alarms help you anticipate unexpected production
halts and minimize downtime. TeSys T is compact and a natural fit for control
protection for your panels with IEC or NEMA standards. In addition, the system’s connectivity
and access to real-time data provide key information so you can enhance the

business operation and safety of your process while improving efficiency.

Proven solutions and support


The TeSys T advanced motor The Schneider Electric™ library of tested, validated, documented architecture
monitoring, control, and protection (TVDA) solutions reduces integration and commissioning time. We also support
the whole project life cycle with network architectures, wiring and design
system is designed to provide guides, and more. Contact our expert at TeSys_US@schneider-electric.com.
top performance, efficiency, and
connectivity, fulfilling the most Key features and benefits

demanding needs • Advanced motor protection from basic to mission-critical applications up to


810A
• Reduce operating costs and downtime with advanced diagnostics and
statistics
• Advance notice of potential issues through intuitive pre-fault alarming
reduces downtime
• Built-in current transformer up to 100A
• Reduced panel size
• Maximum flexibility with expandable I/O and custom programmable logic
• Connectivity to your automation system through multiple industrial protocols

----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
STOP ----------------
----------------
----------------
----------------
START RESET ----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
----------------
--------------

Contact our expert at TeSys_US@schneider-electric.com


schneider-electric.us/tesyst TeSys T Motor Management System | 3
®

Features that help


you do more LTMCU LTMR

PLC (Your automation


TeSys T detailed functionalities and platform)

possible configuration
LTMCU

Network or bus
LTME + LTMR

Protection Functions
• Thermal overload SoMOVE
• Phase imbalance and phase overloads
• Thermal motor protection via temperature probes
• Phase reversal
• Ground fault detection
• Long start and Jam protection SCADA
HMI
• Load shedding LTMR
• Load fluctuations (current, voltage, power)
• Variations of Cos (power factor)

Metering Functions Motor Control Functions


• Phase and average Current A motor managed by a TeSys T controller can be controlled:
• Line to Line and average Voltage
• Locally, using logic inputs present of the product, or via the human machine
• Motor temperature interface (HMI)
• Ground Current • Remotely via the network
• Active & Reactive Power Ten predefined motor control modes are incorporated into the controller (two or
• Active & Reactive energy three-wire):
• Power factor
• Overload mode: Monitoring of motors whose control is not managed by the
• Frequency
controller

Statistical and Diagnostic Functions • Independent mode: Starting of full voltage non-reversing motors
• Reverser mode: Starting of full voltage reversing motors
• History of the last five detected faults
• Two-step mode: Two-step starting of motors (star-delta by auto transformer
• Motor statistics and by resistor)
• Controller operations • Two-speed mode: Two-speed starting of motors (Dahlander, pole changer)
• Warning of potential faults A Custom logic mode is available allowing for user created specific control
schemes.
Communication
Custom Logic has the basic functions of a small programmable logic
TeSys T is a flexible motor management controller (PLC). Programming can be done in structured text mode or in
system that supports five major communication function block diagrams through SoMove. To ensure consistency, the same
protocols Modbus serial, Profibus®, CANopen®, software used to commission TeSys T controller, is used for custom logic
DeviceNet™, Modbus TCP/IP, EtherNet/IP. programming.
These communication protocols allow the TeSys
T controller to integrate seamlessly into your
automation system.

Contact our expert at TeSys_US@schneider-electric.com


schneider-electric.us/tesyst TeSys T Motor Management System | 4
®

Introducing Modbus
TCP and EtherNet/IP
for reliable control
TeSys T now combines industry-
standard Modbus TCP and EtherNet/IP
protocols into one package.

New connectivity options bring new advantages TeSys T with Modbus TCP and EtherNet/IP
gives you:
Ethernet is the perfect choice for fast and failure-resistant connectivity in
industrial control networks. EtherNet/IP enables easier integration of the • Fast integration: Significantly reduced
TeSys T Motor Management System with any PLC, SCADA, or DCS controller configuration and testing time due to standard
package, while providing maximum speed, performance, and reliability during device profiles, preconfigured connections, and
both startup and operation. integration with both Schneider Electric and
third-party PLC, SCADA, and DCS systems
• Real-time exchange: Enhanced bandwidth,
Quality-of-Service message priority, and built-
in java-free web pages support data access,
Overall industrial automation architecture control, and other functions
• Superior reliability: Rapid Spanning Tree Protocol
MES ERP (RSTP) for fast failure recovery, broadcast storm
protection to prevent oversaturation of available
INTERNET TCP/IP
network bandwidth
MAINTENANCE
REMOTE STATION
• Dual Ethernet ports: Fast 100 Mbps peer-
to-peer communication, simple daisy-chain
connections, and support for redundant
SCADA REDUNDANT SERVERS architectures
• Fast device replacement (FDR) allows to replace
the device quickly with automatic download of
MAINTENANCE
configuration
STATION

PLC/DCS CONTROL SYSTEM TeSysT MOTOR MANAGEMENT SYSTEM

Contact our expert at TeSys_US@schneider-electric.com


schneider-electric.us/tesyst TeSys T Motor Management System | 5
®

TeSys T Controller TeSys T Accessories

Reference TeSys T Expansion Module 1, 2

LTM R 100 E BD Control Voltage Reference


24 V DC LTM EV40BD

100..240 V AC LTM EV40FM

1
Required for Voltage and Power measurement
Current Range

2
4 digital inputs
0.4 - 8 A 08

1.35 - 27 A 27 Connector for Expansion


5 - 100 A 100
Length (m) Reference
0.04 LTMCC004 3

0.3 LTM9CEXP03

3
Sold in lots of 6
Network Protocol

CAN Open C

DeviceNet D Operator Control Display


Ethernet E
Description Reference
Modbus M Operator Control Display LTM CU

Operator Control Display LTM CUF


Profibus DP P with configuration backup

Controller to Display Cable


Control
Voltage

24 V DC BD
Length (m) Reference
100 . . .240V AC FM 1.0 LTM9CU10

3.0 LTM9CU30
6 digital inputs/4 relays output
1 input for external ground current sensor
1 input for motor temperature sensor

Current Transformers 4

Primary [A] Secondary [A] Reference


100 1 LT6 CT1001

200 1 LT6 CT2001

400 1 LT6 CT4001

800 1 LT6 CT8001

TeSys T 4
To be used with controller LTM 8 •••

Full and Flexible


Ground Fault CT’s
Intelligent Motor
Management System Primary [A]
65
Internal Ø “d” [mm]
30
Reference
50437

85 50 50438
d 160 80 50439

250 120 50440

400 200 50441

630 300 50442

Contact our expert at TeSys_US@schneider-electric.com


Schneider Electric

8001 Knightdale Blvd.


Knightdale, NC 27545
Phone: 919-266-3671

schneider-electric.us

1, August, 2016
Document Number 8502BR1602

©2015 Schneider Electric. All Rights Reserved. This document has been
All trademarks are owned by Schneider Electric Industries SAS or its affiliated companies. printed on recycled paper

S-ar putea să vă placă și