Sunteți pe pagina 1din 158

A B C D E F G H J K L M N P Q

PLOT 01 - 100% CONSTRUCTION DOCUMENTS FOR TENDER


24.08.2017
STRUCTURE
11

10

Client:

MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
1 Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
Drawing Number

14011603-01-00-SG0000
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

DRAWING LIST PLOT 01 - STRUCTURAL DRAWING LIST PLOT 01 - STRUCTURAL


SHEET NUMBER SHEET NAME SCALE REVISON SHEET NUMBER SHEET NAME SCALE REVISON
14011603-01-00-SG0000 COVER SHEET - STRUCTURAL N.T.S 0 BUILDING 01
14011603-01-00-SG0001 DRAWING LIST - STRUCTURAL N.T.S 0 14011603-01-01-SC1000 GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN 1:150 0
14011603-01-00-SG0002 STRUCTURAL GENERAL NOTES - 01 N.T.S 0 14011603-01-01-SC1001 LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN 1:150 0 N
10
14011603-01-00-SG0003 STRUCTURAL GENERAL NOTES - 02 N.T.S 0 14011603-01-01-SC1002 LEVEL 02 - COLUMNS & WALLS SETTING OUT PLAN 1:150 0
KEY PLAN
14011603-01-00-SG0004 STRUCTURAL GENERAL NOTES - 03 N.T.S 0 14011603-01-01-SC1003 LEVEL 03 - COLUMNS & WALLS SETTING OUT PLAN 1:150 0
14011603-01-00-SG0005 STRUCTURAL GENERAL NOTES - 04 N.T.S 0 14011603-01-01-SC1004 LEVEL 04 - COLUMNS & WALLS SETTING OUT PLAN 1:150 0
14011603-01-00-SG0006 STRUCTURAL GENERAL DETAILS - 01 N.T.S 0 14011603-01-01-SC1005 LOWER ROOF LEVEL - COLUMNS & WALLS SETTING OUT PLAN 1:150 0
14011603-01-00-SG0007 STRUCTURAL GENERAL DETAILS - 02 N.T.S 0
14011603-01-00-SG0008 STRUCTURAL GENERAL DETAILS - 03 N.T.S 0 14011603-01-01-SF1001 LEVEL 01 - FRAMING PLAN 1:150 0
14011603-01-00-SG0009 STRUCTURAL GENERAL DETAILS - 04 N.T.S 0 14011603-01-01-SF1002 LEVEL 02 - FRAMING PLAN 1:150 0
14011603-01-00-SG0010 STRUCTURAL GENERAL DETAILS - 05 N.T.S 0 14011603-01-01-SF1003 LEVEL 03 - FRAMING PLAN 1:150 0
14011603-01-00-SG0011 STRUCTURAL GENERAL DETAILS - 06 N.T.S 0 14011603-01-01-SF1004 LEVEL 04 - FRAMING PLAN 1:150 0
14011603-01-00-SG0012 STRUCTURAL GENERAL DETAILS - 07 N.T.S 0 14011603-01-01-SF1005 LOWER ROOF LEVEL - FRAMING PLAN 1:150 0
9 14011603-01-00-SG0013 STRUCTURAL GENERAL DETAILS - 08 N.T.S 0 14011603-01-01-SF1006 ROOF LEVEL - FRAMING PLAN 1:150 0
14011603-01-00-SG0014 STRUCTURAL GENERAL DETAILS - 09 N.T.S 0
14011603-01-00-SG0015 STRUCTURAL GENERAL DETAILS - 10 N.T.S 0 14011603-01-01-SL1001 LEVEL 01 - LOADING PLAN 1:150 0
14011603-01-00-SG0016 STRUCTURAL GENERAL DETAILS - 11 N.T.S 0 14011603-01-01-SL1002 LEVEL 02 - LOADING PLAN 1:150 0
14011603-01-00-SG0017 STRUCTURAL GENERAL DETAILS - 12 N.T.S 0 14011603-01-01-SL1003 LEVEL 03 - LOADING PLAN 1:150 0 General Notes:
14011603-01-00-SG0018 STRUCTURAL GENERAL DETAILS - 13 N.T.S 0 14011603-01-01-SL1004 LEVEL 04 - LOADING PLAN 1:150 0
1. DO NOT SCALE FROM THIS DRAWING.
14011603-01-00-SG0019 STRUCTURAL GENERAL DETAILS - 14 N.T.S 0 14011603-01-01-SL1005 LOWER ROOF LEVEL - LOADING PLAN 1:150 0
14011603-01-00-SG0020 STRUCTURAL GENERAL DETAILS - 15 N.T.S 0 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
14011603-01-00-SG0021 STRUCTURAL GENERAL DETAILS - 16 N.T.S 0 14011603-01-01-S5201 CORE WALL DETAILS - 01 1:50 0 BY THE ENGINEER.
14011603-01-00-SG0022 STRUCTURAL GENERAL DETAILS - 17 N.T.S 0 14011603-01-01-S5202 CORE WALL DETAILS - 02 1:50 0
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
14011603-01-00-SG0023 STRUCTURAL GENERAL DETAILS - 18 N.T.S 0 14011603-01-01-S5203 CORE WALL DETAILS - 03 1:50 0 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
14011603-01-00-SG0024 STRUCTURAL GENERAL DETAILS - 19 N.T.S 0
14011603-01-00-SG0025 STRUCTURAL GENERAL DETAILS - 20 N.T.S 0 14011603-01-01-S6101 COLUMN & WALL SCHEDULES - 01 1:25 0 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
14011603-01-00-SG0026 STRUCTURAL GENERAL DETAILS - 21 N.T.S 0 14011603-01-01-S6102 COLUMN & WALL SCHEDULES - 02 1:25 0 AND RELEVANT SECTIONS OF THE SPECIFICATION.
14011603-01-00-SG0027 STRUCTURAL GENERAL DETAILS - 22 N.T.S 0 14011603-01-01-S6103 COLUMN & WALL SCHEDULES - 03 1:25 0
14011603-01-01-S6104 COLUMN & WALL SCHEDULES - 04 1:25 0
14011603-01-00-SE0100 EXCAVATION PLAN 1:350 0 14011603-01-01-S6105 COLUMN & WALL SCHEDULES - 05 1:25 0
14011603-01-00-SP0999 BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - OVERALL 1:350 0 14011603-01-01-S6201 BEAMS SCHEDULE-01 N.T.S 0
14011603-01-00-SP0999a BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART A 1:150 0 14011603-01-01-S6202 BEAMS SCHEDULE-02 N.T.S 0
14011603-01-00-SP0999b BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART B 1:150 0 BUILDING 02
14011603-01-00-SP0999c BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART C 1:150 0 14011603-01-02-SC1000 GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
7 14011603-01-02-SC1000a GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0
14011603-01-00-SC0999 BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT - OVERALL PLAN 1:350 0 14011603-01-02-SC1000b GROUND LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0
14011603-01-00-SC0999a BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT - PART A 1:150 0 14011603-01-02-SC1001 LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
14011603-01-00-SC0999b BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT - PART B 1:150 0 14011603-01-02-SC1001a LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0
14011603-01-00-SC0999c BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT - PART C 1:150 0 14011603-01-02-SC1001b LEVEL 01 - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0
14011603-01-02-SC1002 LEVEL 02 - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
14011603-01-00-SF1000 GROUND LEVEL - FRAMING PLAN - OVERALL 1:350 0 14011603-01-02-SC1002a LEVEL 02 - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0
14011603-01-00-SF1000a GROUND LEVEL - FRAMING PLAN - PART A 1:150 0 14011603-01-02-SC1002b LEVEL 02 - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0
14011603-01-00-SF1000b GROUND LEVEL - FRAMING PLAN - PART B 1:150 0 14011603-01-02-SC1003 LEVEL 03 - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
14011603-01-00-SF1000c GROUND LEVEL - FRAMING PLAN - PART C 1:150 0 14011603-01-02-SC1003a LEVEL 03 - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0
14011603-01-02-SC1003b LEVEL 03 - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0
6 14011603-01-00-SRB0999 BASEMENT 01 LEVEL - BOTTOM REINFORCEMENT PLAN - OVERALL 1:350 0 14011603-01-02-SC1004 LEVEL 04 - COLUMNS & WALLS SETTING OUT PLAN - OVERALL 1:200 0
14011603-01-00-SRB0999a BASEMENT 01 LEVEL - BOTTOM REINFORCEMENT PLAN - PART A 1:150 0 14011603-01-02-SC1004a LEVEL 04 - COLUMNS & WALLS SETTING OUT PLAN - PART A 1:150 0
14011603-01-00-SRB0999b BASEMENT 01 LEVEL - BOTTOM REINFORCEMENT PLAN - PART B 1:150 0 14011603-01-02-SC1004b LEVEL 04 - COLUMNS & WALLS SETTING OUT PLAN - PART B 1:150 0
14011603-01-00-SRB0999c BASEMENT 01 LEVEL - BOTTOM REINFORCEMENT PLAN - PART C 1:150 0 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
14011603-01-00-SRT0999 BASEMENT 01 LEVEL - TOP REINFORCEMENT PLAN - OVERALL 1:350 0 14011603-01-02-SF1001 LEVEL 01 - FRAMING PLAN - OVERALL 1:200 0 AUTHORITY APPROVAL 0 17.08.2017 NS
14011603-01-00-SRT0999a BASEMENT 01 LEVEL - TOP REINFORCEMENT PLAN - PART A 1:150 0 14011603-01-02-SF1001a LEVEL 01 - FRAMING PLAN - PART A 1:150 0 Purpose of Issue Rev. Date Appoved
14011603-01-00-SRT0999b BASEMENT 01 LEVEL - TOP REINFORCEMENT PLAN - PART B 1:150 0 14011603-01-02-SF1001b LEVEL 01 - FRAMING PLAN - PART B 1:150 0
Client:
14011603-01-00-SRT0999c BASEMENT 01 LEVEL - TOP REINFORCEMENT PLAN - PART C 1:150 0 14011603-01-02-SF1002 LEVEL 02 - FRAMING PLAN - OVERALL 1:200 0
14011603-01-02-SF1002a LEVEL 02 - FRAMING PLAN - PART A 1:150 0
14011603-01-00-SR1000 GROUND LEVEL - REINFORCEMENT PLAN - OVERALL 1:350 0 14011603-01-02-SF1002b LEVEL 02 - FRAMING PLAN - PART B 1:150 0
5 14011603-01-00-SR1000a GROUND LEVEL - REINFORCEMENT PLAN - PART A 1:150 0 14011603-01-02-SF1003 LEVEL 03 - FRAMING PLAN - OVERALL 1:200 0
14011603-01-00-SR1000b GROUND LEVEL - REINFORCEMENT PLAN - PART B 1:150 0 14011603-01-02-SF1003a LEVEL 03 - FRAMING PLAN - PART A 1:150 0 MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
14011603-01-00-SR1000c GROUND LEVEL - REINFORCEMENT PLAN - PART C 1:150 0 14011603-01-02-SF1003b LEVEL 03 - FRAMING PLAN - PART B 1:150 0 T: +9714 3270000 F: +9714 3270007
14011603-01-02-SF1004 LEVEL 04 - FRAMING PLAN - OVERALL 1:200 0 E: info@dubairacingclub.com W: www.dubairacingclub.com

14011603-01-00-S5101 FOUNDATION DETAILS - 01 1:50 0 14011603-01-02-SF1004a LEVEL 04 - FRAMING PLAN - PART A 1:150 0 Principal Consultant:
14011603-01-00-S5102 FOUNDATION DETAILS - 02 1:50 0 14011603-01-02-SF1004b LEVEL 04 - FRAMING PLAN - PART B 1:150 0
14011603-01-00-S5103 FOUNDATION DETAILS - 03 1:25 0 14011603-01-02-SF1005 ROOF LEVEL - FRAMING PLAN - OVERALL 1:200 0
14011603-01-00-S5104 FOUNDATION DETAILS - 04 1:25 0 14011603-01-02-SF1005a ROOF LEVEL - FRAMING PLAN - PART A 1:150 0
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
14011603-01-00-S5105 FOUNDATION DETAILS - 05 1:25 0 14011603-01-02-SF1005b ROOF LEVEL - FRAMING PLAN - PART B 1:150 0 www.ae-7.com
14011603-01-00-S5106 FOUNDATION DETAILS - 06 1:25 0 Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
14011603-01-00-S5107 FOUNDATION DETAILS - 07 1:25 0 14011603-01-02-SL1001 LEVEL 01 - LOADING PLAN 1:200 0 P: +971 4 3997758 F: +971 4 3997759
4 14011603-01-00-S5108 FOUNDATION DETAILS - 08 1:25 0 14011603-01-02-SL1002 LEVEL 02 - LOADING PLAN 1:200 0 Sub-Consultant:
14011603-01-00-S5109 FOUNDATION DETAILS - 09 1:25 0 14011603-01-02-SL1003 LEVEL 03 - LOADING PLAN 1:200 0
14011603-01-00-S5301 SLAB DETAILS - 01 1:25 0 14011603-01-02-SL1004 LEVEL 04 - LOADING PLAN 1:200 0
14011603-01-00-S5302 SLAB DETAILS - 02 1:25 0 14011603-01-02-SL1005 ROOF - LOADING PLAN 1:200 0
14011603-01-00-S5303 SLAB DETAILS - 03 1:25 0
14011603-01-00-S5304 SLAB DETAILS - 04 1:25 0 14011603-01-02-S5201 CORE WALL DETAILS - 01 1:50 0
14011603-01-00-S5305 SLAB DETAILS - 05 1:25 0 14011603-01-02-S5202 CORE WALL DETAILS - 02 1:50 0
14011603-01-00-S5306 SLAB DETAILS - 06 1:100 0 14011603-01-02-S5203 CORE WALL DETAILS - 03 1:50 0
14011603-01-00-S5307 SLAB DETAILS - 07 1:25 0 14011603-01-02-S5204 CORE WALL DETAILS - 04 1:50 0 Project Name:
14011603-01-00-S5308 SLAB DETAILS - 08 AS INDICATED 0
3 14011603-01-00-S5501 STAIRS DETAILS - 01 1:50 0 14011603-01-02-S6101 COLUMN & WALL SCHEDULES - 01 1:25 0 DUBAI WATER CANAL
14011603-01-00-S5502 STAIRS DETAILS - 02 1:50 0 14011603-01-02-S6102 COLUMN & WALL SCHEDULES - 02 1:25 0 SAFA A
14011603-01-00-S5503 STAIRS DETAILS - 03 1:50 0 14011603-01-02-S6103 COLUMN & WALL SCHEDULES - 03 1:25 0
14011603-01-00-S5504 STAIRS DETAILS - 04 1:50 0 14011603-01-02-S6104 COLUMN & WALL SCHEDULES - 04 1:25 0 DUBAI-UAE
14011603-01-00-S5505 STAIRS DETAILS - 05 1:50 0 14011603-01-02-S6105 COLUMN & WALL SCHEDULES - 05 1:25 0
14011603-01-00-S5506 STAIRS DETAILS - 06 1:50 0 14011603-01-02-S6201 BEAMS SCHEDULE-01 N.T.S 0 Project Description:
14011603-01-00-S5507 STAIRS DETAILS - 07 1:50 0 14011603-01-02-S6202 BEAMS SCHEDULE-02 N.T.S 0
14011603-01-00-S5508 STAIRS DETAILS - 08 1:25 0
MIXED USE DEVELOPMENT
14011603-01-00-S5601 RAMP DETAILS - 01 1:100 0 (RETAIL & RESIDENTIAL)
14011603-01-00-S5602 RAMP DETAILS - 02 1:50 0 PLOT 01 / 3435338
14011603-01-00-S5603 RAMP DETAILS - 03 1:50 0
2 14011603-01-00-S5901 WATER TANK DETAILS 1:50 0
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:
14011603-01-00-S6001 PILE CAP SCHEDULE N.T.S 0
14011603-01-00-S6301 SLAB REINFORCMENET SCHEDULES N.T.S 0
14011603-01-00-S6302 SLAB REINFORCMENET SCHEDULES N.T.S 0
DRAWING LIST - STRUCTURAL

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-00-SG0001 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
2-11. CONCRETE GRADES SHALL BE AS FOLLOWS, UNLESS NOTED 3. NOTES OF DESIGN LOAD CRITERIA
1. GENERAL NOTES OTHERWISE:-

1-1. ALL STRUCTURAL DRAWINGS TO BE READ IN CONJUNCTION WITH RELEVANT ARCHITECT'S 3-1. GRAVITY LOADS
CONCRETE GRADE GGBS MODULUS OF
DRAWINGS, SERVICES ENGINEER'S DRAWINGS, SPECIFICATIONS AND PRELIMINARIES. ELEMENTS CEMENT SUPERIMPOSED DEAD LOAD (SDL) (kPa)
CUBIC / CYLINDER (%) ELACTICITY LIVE LOAD
(N/mm2) TYPE (Ec) Mpa
FLOOR USAGE
1-2. FOR SETTING OUT REFER TO ARCHITECTURAL DRAWINGS. FINISHES SERVICES & PARTITIONS & (LL) (kPa)
1-3. ALL DIMENSIONS ARE IN MILLIMETRES UNLESS OTHERWISE STATED.
CEILING BRICK WALLS
PILE C50 / 40 OPC 55% 29725
INACCESSIBLE LIGHT ROOF 2.50 0.50 ---- 1.00
1-4. DO NOT SCALE FROM DRAWINGS. ONLY FIGURED DIMENSIONS ON THE DRAWINGS ARE TO FOUNDATIONS / PILE CAPS C60 / 50 OPC 55% 37721
BE USED. MEMBERS ARE PLACED SYMMETRICALLY ABOUT GRIDLINES UNLESS NOTED 4.00 ---- 2.00 N
10 ACCESSIBLE ROOF 0.50 KEY PLAN
OTHERWISE. COLUMNS / SHEAR WALLS C60 / 50 OPC ---- 37721
MEP ROOF 4.50 0.50 ---- 5.00
1-5. FOR DIMENSIONS AND SETTING OUT OF NON-STRUCTURAL COLUMNS/WALLS, PARAPETS BASEMENT RETAINING WALL/ STAIRS /
C45 / 36 OPC 55% 28200
AND CLADDING WALL DETAILS, REFER TO ARCHITECTURAL / CIVIL DRAWINGS. RAMPS/UP-STANDS CHILLER ROOF 9.50 0.50 ---- 7.50
1-6. ALL LEVELS ARE MENTIONED IN (m) AND SHALL BE READ WTIH THE THE ARCHITECTURAL WATER TANK C60 / 50 OPC 55% 37721 RESIDENTIAL 1.70 5.60 2.00
0.50
DRAWINGS. BEAMS / SLABS C60 / 50 OPC ---- 37721 LOBBY ----
0.50 5.00
TRANSFER BEAMS / SLABS C60 / 50 OPC ---- 2.50
1-7. ALL STRUCTURAL WORKS SHALL COMPLY WITH THE SPECIFICATIONS, SPECIFIED 37721
STANDARD CODES AND OTHER RELEVANT UAE STANDARDS. WHERE STRUCTURAL SWIMMING POOL C60 / 50 OPC 55% 37721 CAR PARK 1.00 0.50 ---- 3.50
REQUIREMENTS ARE COVERED BY MORE THAN ONE DOCUMENT, THE STRONGEST BLINDING C25 / 20 OPC ---- ----
9 REQUIREMENTS SHALL APPLY. 4.50 0.50 ----
GYM 5.00

1-8. UNLESS OTHERWISE STATED ON THE DRAWINGS, SIZE OF STRUCTURAL MEMBERS ARE RETAILS 11.50 0.50 ---- 5.00
SHOWN AS FOLLOWS : e.g. (200) - 200mm THICK WALL UNDER, (150) - 150mm THICK SLAB.
LANDSCAPE AREA VARIOUS General Notes:
1-9. THE SUPERIMPOSED LIVE LOADS AND SUPERIMPOSED DEAD LOADS SPECIFIED AS 1. DO NOT SCALE FROM THIS DRAWING.
FACADE VARIOUS
CHARACTERISTIC LOADS. TEMPORARY LOADS DURING CONSTRUCTION MUST NOT EXCEED
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
THE SPECIFIED CHARACTERISTIC LOADS UNLESS OTHERWISE STATED ON THE DRAWING. 2-12. COVER TO ALL REINFORCEMENT TO BE AS FOLLOWS, NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
UNLESS NOTED OTHERWISE : BY THE ENGINEER.

1-10. ALL STRUCTURES SUPPORTED BY HANGER MUST REMAIN PROPPED UNTIL THE 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 SUPPORTING STRUCTURES ARE CAST AND HAVE GAINED THE REQUIRED STRENGTH. CONDITION COVER (mm) SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
AT SITE.

CONCRETE CAST IN WATER 100mm 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
1-11. FOR DETAILS OF ALL NON-STRUCTURAL CONCRETE ELEMENTS INCLUDING CONCRETE
CONCRETE CAST AGAINST & PERMANENTLY 75mm
AND RELEVANT SECTIONS OF THE SPECIFICATION.
SURROUNDINGS TO PIPES/DUCTS, KERBS, DRAINAGE CHANNELS, PLINTHS FOR
EXPOSED TO EARTH 3-2. WIND LOADS
MECHANICAL PLANT AND EQUIPMENT, REFER TO THE RELEVANT ARCHITECTURAL AND
SERVICES ENGINEER. PILES 75mm 3-2-1. WIND LOADS BASED ON ASCE 7-05, WITH THE FOLLOWING DATA;
FOUNDATIONS / PILE CAPS 75mm EARTH FACES, AND 50mm OTHER FACES - DESIGN WIND SPEED 45 m/s
1-12. ANY INFORMATION CONCERNING THE NATURE OF THE GROUND FROM THE AVAILABLE
SITE INVESTIGATION REPORTS IS GIVEN IN GOOD FAITH AND NO GUARANTEE IS GIVEN OF COLUMNS & SHEAR WALLS 50mm EXTERNAL, AND 40mm INTERNAL - EXPOSURE CATEGORY C
ITS ACCURACY OR APPLICABILITY THROUGHOUT THE SITE.
7 - IMPORTANCE FACTOR 1.00 (TABLE 6-1)
BASEMENT RETAINING WALLS 75mm EARTH FACES, AND 50mm OTHER FACES
1-13. THE CONTRACTOR SHALL EXERCISE ALL NECESSARY CARE AND DILIGENCE IN THE 70mm ATTACHED TO WATER - DIRECTIONALITY FACTOR 0.85 (TABLE 6-4)
EXECUTION OF THE WORKS SUCH THAT THE EXISTING BUILDINGS, ROADS, PAVEMENTS - TOPOGRAPHIC FACTOR, Kzt 1.00 (TABLE 6-4)
AND UTILITIES ARE NOT AFFECTED. SUSPENDED FLOOR SLABS / STIARS / RAMPS 40mm EXTERNAL, AND 30mm INTERNAL
- WINDWARD COEFFICIENT, cp 0.80
SUSPENDED FLOOR BEAMS / LINK BEAMS 50mm ALL SIDES - LEEWARD COEFFICIENT 0.50
1-14. PRIOR TO THE COMMENCEMENT OF THE WORKS THE CONTRACTOR SHALL SUBMIT A - LOADING CASE "ASCE7-05 ALL CASES (Fig. 9-6)
PRE-CONDITION SURVEY REPORT OF THE NEIGHBORING GROUND, ROADS AND WATER TANKS 50mm ALL SIDES
STRUCTURES SURROUNDING THE PROPOSED SITE AND THE RESULTS OF CADASTRAL - GUST FACTOR 1
SURVEY CONFIRMING THE SITE BOUNDARY LINE WITH HIS/HER OWN EXPENSES. PARAPET 30mm ALL SIDES
6
1-15. BEFORE EXCAVATIONS ARE CARRIED OUT NEAR UTILITY SERVICES BY MEANS OF 3-2-2 SEISMIC LOADS BASED ON UBC1997, WITH THE FOLLOWING DATA
MECHANICAL PLANT, THE CONTRACTOR SHALL CARRY OUT FULL AND ADEQUATE 2-13. THE MAXIMUM AGGREGATE SIZE SHALL BE 20mm FOR ALL CONCRETE MIX, UNLESS NOTED
PRELIMINARY INVESTIGATIONS BY MEANS OF HAND-DUG INSPECTION PITS. OTHERWISE
- SEISMIC ZONE 2A 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
1-16. THE CONTRACTOR SHALL LIAISE WITH UTILITY UNDERTAKERS, OBTAIN THEIR APPROVAL 2-14. THE REACTIVE ALKALI CONTENT OF CONCRETE EXPRESSED AS THE EQUIVALENT SODIUM - SEISMIC ZONE FACTOR 0.15 TABLE (16-I) AUTHORITY APPROVAL 0 17.08.2017 NS
AND PAY ALL COSTS FOR THE TREATMENT AND DISPOSAL OF SEWAGE AND OXIDE CONTENT / CUBIC METER OF CONCRETE SHOULD NOT EXCEED 3.0kg. Purpose of Issue Rev. Date Appoved
WASTEWATER FROM THE SITE TO THEIR APPROVAL. - SOIL PROFILE TYPE SC (TO BE CONFIRMED BY SOIL REPORT)
Client:
- IMPORTANCE FACTOR 1.00 TABLE (16-K)
2-15. ALL BARS TO BE HIGH YIELD DEFORMED BARS TYPE II AND CONFORM WITH BS 4449:2005
1-17. THE CONTRACTOR SHALL NOT DO OR PERMIT ANYTHING TO BE DONE WITHIN THE SITE THAT AND WITH A GUARANTEED MINIMUM YIELD STRESS OF 460 N/mm2 . - IMPORTANCE OVER STRENGTH FACTOR 4.50 FOR SHEAR WALL LATERAL SYSTEM
MAY BECOME A NUISANCE OR ANNOYANCE TO THE OCCUPANTS OF NEARBY PREMISES.
5 - SEISMIC COEFFICIENT (Ca) 0.18 TABLE (A6-Q)
2-16. UNLESS NOTED OTHERWISE, ALL LAP LENGTH AND ANCHORAGE VALUES OF - SEISMIC COEFFICIENT (Cv) 0.25 TABLE (16-R) MEYDAN L.L.C
1-18. THE CONTRACTOR SHALL PROPOSE MEASURES ON GROUNDWATER CONTROL WITHIN THE REINFORCEMENT SHALL BE IN ACCORDANCE WITH AMERICAN STANDARD (ACI 318-11) P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
SITE TO ENSURE DRY EXCAVATION IN RESPECT TO THE NATURE OF THE GROUND. E: info@dubairacingclub.com W: www.dubairacingclub.com
2-17. REINFORCEMENT CONSISTING OF EXPANDED METAL LATH OR WIRE FABRIC Principal Consultant:
1-19. THE CONTRACTOR SHALL BE RESPONSIBLE FOR GETTING APPROVAL OF EASEMENT FROM (MIN. 0.5 kg/m2 ) WITH 2mm DIAMETER WIRE AT NOT MORE THAN 100mm CENTERS OR A
RELEVANT AUTHORITY OR OWNER FOR INSTALLATION OF GROUND ANCHORS PROTRUDED CONTINUOUS ARRANGEMENT OF LINKS AT NOT MORE THAN 200mm CENTERS SHALL BE 3-4. THERMAL VARIATION
OUTSIDE SITE BOUNDARY. INCORPORATED IN THE CONCRETE COVER (BOTTOM AND SIDE FACES ONLY) AT A
DISTANCE NOT EXCEEDING 30mm FROM THE FACE. - SUPER - STRUCTURE ∆ T = +/- 20° abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
1-20. NO ROCK REMOVAL BY BLASTING IS ALLOWED WITHOUT PRIOR APPROVAL OF THE ENGINEER - SUB - STRUCTURE ∆ T = +/- 10° Hassanicor Building, 6th Floor, Al Barsha 1
AND AUTHORITY. 2-18. ALL COUPLERS IF APPLICABLE SHALL BE SCREWED COUPLERS AND PO Box 54115 Dubai, UAE
4 WELDABLE SCREWED COUPLERS OR EQUIVALENT APPROVED AND SHALL BE CAPABLE P: +971 4 3997758 F: +971 4 3997759
OF TRANSFERRING THE FULL DESIGN TENSION, COMPRESSION CAPACITY OF THE 3-5. EARTH PRESSURE Sub-Consultant:
1-21. ALL BIDDERS / CONTRACTORS SHALL BE OBLIGED TO VISIT THE SITE AND ASSESS THE SITE CONNECTED REINFORCEMENT. THE COUPLERS SHALL BEINSTALLED ACCORDING TO THE
CONDITION PRODUCT SPECIFICATIONS. - UNIT WEIGHT OF DRY SOIL = 18kN/m3
- UNIT WEIGHT OF SATURATED SOIL = 20kN/m3
2-19. COUPLER SHALL BE USED WHERE THE REINFORCEMENT PERCENTAGE
2. NOTES ON STRUCTURAL CONCRETE AT LAPPING LOCATIONS EXCEEDS 8%. - UNIT WEIGHT OF WATER SOIL = 10kN/m3

2-1. STRUCTURAL CONCRETE NOTES TO BE READ IN CONJUNCTION WITH ALL RELEVANT 3-6. CONSTRUCTION MATERIAL DENSITIES Project Name:
ARCHITECTURAL / MEP DRAWINGS, SPECIFICATIONS, AND EMPLOYER REQUIREMENTS. DENSITY
3
MATERIAL
(kN/m3) DUBAI WATER CANAL
2-2. ALL CONCRETE WORKS SHALL CONFORM WITH ACI318-11. STEEL 78.50 SAFA A
REINFROCED CONCRETE 25 DUBAI-UAE
2-3. ALL CEMENT SHALL BE ORDINARY PORTLAND CEMENT (CEM1).
PLAIN CONCRETE 22 Project Description:
2-4. WELDING OF REINFORCEMENT IS NOT PERMITTED.
MIXED USE DEVELOPMENT
2-5. ALL AREAS WHERE CONCRETE IS TO BE PLACED MUST BE CLEANED AND FREE OF (RETAIL & RESIDENTIAL)
STANDING WATER IMMEDIATELY BEFORE PLACING OF CONCRETE.
PLOT 01 / 3435338
4. PROJECT GENERAL LIMITATIONS
2 2-6. CORROSION INHIBITOR SHALL BE PROVIDED TO THE CONCRETE MIX FOR ALL SUB BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
STRUCTURE ELEMENTS. INCLUDING PILES, EXCEPTING SHORING PILES.
4-1. THE SLABS BELOW THE TRANSFER FLOOR LEVEL ARE NOT DESIGNED TO SUPPORT Drawing Title:
OWN WEIGHT OF THE TRANSFER SLABS/ BEAMS, SO THE CONTRACTOR SHALL KEEP
2-7. FOR DETAILS OF CONCRETE FINISHES, REFER TO ARCHITECTURAL DRAWINGS. THE SCAFFLODING FROM THE FOUNDATION LEVEL UP TO TRANSFER LEVEL UNTIL 56 DAYS
AFTER CASTING TRNASFER FLOOR OR AS INSTRUCTED BY THE ENGINEER. STRUCTURAL GENERAL NOTES - 01
2-8. MASS CONCRETE FILL (PLAIN CONCRETE) SHALL COMPLY WITH ACI318-11 UNLESS NOTED
OTHERWISE. 4-2. PT SPECIALIST SHALL CONSIDER ALL THERMAL EFFECT ON PT SLABS AND BEAMS IN
COLLABORATION WITH THE MAIN CONSULTANT.
Scale Drawn Checked Approved Size
2-9. ALL R.C. ELEMENTS ARE DESIGNED TO AMERICAN STANDARD ACI 318-11 AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
2-10. 75mm THICK BLINDING SHALL BE LAID UNDERNEATH FOUNDATIONS / PILE CAPS
Drawing Number Rev.

14011603-01-01-00-SG0002 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

5. NOTES ON PILES DUBAI MUNICIPALITY STAMP:


DEWATERING - THE CONSTRUCTION OF SHORING WALL AND ELS WORKS SHALL NOT INDUCE ANY ADVERSE
5-1. UNLESS OTHERWISE INDICATED ON DRAWINGS, ELEVATIONS ARE IN METERS,DIMENSIONS AND
DEWATERING SHALL BE SWITCHED OFF 28 DAYS AFTER CASTING COMPLETE THE ENTIRE EFFECT ON ADJACENT STRUCTURES, UTILITIES AND FACILITIES. A DETAILED ANALYSIS ON
REINFORCEMENT BAR SIZES IN mm THE MOVEMENT OF THE SHORING WALL AND THE ADJACENT GROUND/STRUCTURES, AND A
GROUND FLOOR SLAB AND SHALL BE APPROVED IN WRITING BY THE ENGINEER.
11
5-2. DESIGN AND CONSTRUCTION OF PILES ARE IN ACCORDANCE WITH THE BUILDING CODE DETAILED ASSESSMENT ON THE EFFECT ON ADJACENT STRUCTURE, UTILITIES AND
REQUIREMENTS FOR STRUCTURAL CONCRETE ACI 318-08 AND ALSO SHALL COMPLY ALL LOCAL Important Note: FACILITIES SHALL BE CARRIED OUT BY THE CONTRACTOR TO THE SATISFACTION OF THE
REGULATIONS/CODES OF DUBAI. ENGINEER. THE LATERAL MOVEMENT OF THE SHORING WALL SHALL BE LIMITED TO 30mm IN
HIGH STRAIN DYNAMIC LOAD TEST, LOW STRAIN INTEGRITY TEST & CROSS HOLE LOGGING
5-3. THE SPECIFIED 28 DAY CYLINDER COMPRESSIVE STRENGTH OF CONCRETE (FOR PILES) IS 40 N/mm . INTEGRITY TEST SHALL BE DONE ON THE NON WORKING COMPRESSION PILES BEFORE THE ALL CASE UNLESS OTHERWISE APPROVED BY THE ENGINEER. THE MAXIMUM ALLOWABLE
5-4. TRIAL MIXES MUST BE PERFORMED AND 28 DAY COMPRESSIVE STRENGTHS & DURABILITY EXECUTION OF THE STATIC AXIAL COMPRESSION LOAD TEST. INDUCED GROUND SETTLEMENT DUE TO THE SHORING WALL AND ELS WORKS SHALL BE
TEST RESULTS MUST BE SUBMITTED TO THE ENGINEER FOR HIS APPROVAL PRIOR TO ANY GENERALLY 50mm BUT IT SHALL NOT BE APPLIED TO STRUCTURES OR UTILITIES OF WHICH
CONCRETE WORK FOR PERMANENT WORKS. 6. NOTES FOR DESIGN OF TEMPORARY SHORING WALL,AND LATERAL MORE STRINGENT REQUIREMENT TO THE APPROVAL OF THE ENGINEER SHALL BE ADOPTED;
5-5. ALL REINFORCING STEEL BARS SHALL BE DEFORMED HIGH GRADE STEEL HAVING A MINIMUM SUPPORT SYSTEM
YIELD STRENGTH OF 460 N/mm2 TO ASTM A615. - THE LATERAL SUPPORT LAYOUT OF THE ELS WORKS DESIGNED BY THE CONTRACTOR SHALL
6-1. THE DESIGN OF TEMPORARY SHORING WALL, LATERAL SUPPORT SYSTEM AND PILING N
10 5-6. THE PILE LONGITUDINAL REINFORCEMENT SHALL EXTEND ALL OVER THE PILE FULL LENGTH. NOT OBSTRUCT THE CONSTRUCTION OF THE PERMANENT STRUCTURE WITHOUT PRIOR KEY PLAN
WORKS SHALL BE CARRIED OUT BY THE CONTRACTOR TO THE APPROVAL OF THE
5-7. THE PILE LONGITUDINAL REINFORCEMENT EXTENSION ABOVE THE CUT OFF LEVEL INDICATED IN ENGINEER, AND IF NECESSARY, RELEVANT GOVERNMENT AUTHORITIES IN DUBAI. APPROVAL BY THE ENGINEER;
THE PILE SCHEDULE SHALL NOT BE LESS THAN 50 TIMES DIA. OF THE MAIN REINFORCEMENT.
6-2. THE CONTRACTOR SHALL PREPARE AND SUBMIT IN THE TENDER THE DESIGN WITH
- THE COMBINED THICKNESS OF THE SHORING WALL INCLUDING WALL DEFLECTION,
5-8. A FULL MECHANICAL SPLICE SHALL BE USED FOR ALL LONGITUDINAL REINFORCEMENT TO DETAILED PLANS, CALCULATIONS AND EXPLANATORY NOTES. THE DRAWINGS CONSTRUCTION TOLERANCE AND ANCHOR HEAD (IF ANY SHALL NOT BE MORE THAN 1.10m
DEVELOP IN TENSION OR COMPRESSION, AS REQUIRED, AT LEAST 125% OF THE SPECIFIED INCLUDING PLANS AND SECTIONS INDICATED IN THE TENDER DRAWINGS ARE FOR UNLESS OTHERWISE AGREED BY THE ENGINEER. IN ANY CASE, THE BASEMENT AREA SHALL
YIELD STRENGTH Fy OF THE BAR. MECHANICAL COUPLERS SHALL BE TESTED IN THE INFORMATION ONLY AND IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO NOT BE SACRIFICED DUE TO CONSTRUCTION OF THE SHORING WALL;
LABORATORY IN ACCORDANCE WITH ACI 318-08. VERIFY AND UNDERTAKE HIS DESIGN.
- THE SHORING WALL AND ELS SYSTEM SHALL BE DESIGNED FOR THE HEIGHT SHOWN ON
5-9. ALL PILES SHALL BE OF CAST-IN-SITU BORED SYSTEM . 6-3. ALL TIME AND COST PERTAINING TO THE DESIGN WORKS SHALL BE SOLELY ON THE DRAWINGS.
CONTRACTOR'S EXPENSES.
5-10. NO ROCK REMOVAL BY BLASTING IS ALLOWED WITHOUT PRIOR APPROVAL OF THE ENGINEER 6-4. THE PROPOSED TEMPORARY SHORING WALL SHALL BE BASED ON THE ASSUMPTION - THE FREE LENGTH OF GROUND ANCHOR SHALL EXTEND BEYOND THE CRITICAL FAILURE
9 AND AUTHORITY. THAT TIE BACKS/ANCHORS ARE REQUIRED TO PROVIDE AS THE LATERAL SUPPORT FOR SURFACE IN THE ROCK OR SOIL MASS BEING RETAINED BY THE WALL. THE BOND LENGTH
5-11. THE CAPACITY OF THE SOIL/ROCK FOR BEARING, BOND OR FRICTION SHALL POSSESS A THE SYSTEM. HOWEVER, SHOULD THIS NOT BE POSSIBLE, ALTERNATIVES SUCH AS
MINIMUM FACTOR OF SAFETY OF 2.5 UNDER COMPRESSION AND TENSION.
SHALL BE MINIMUM OF 4m AND LOCATED A MINIMUM DEPTH OF 5m BELOW THE GROUND
CANTILEVER WALL OR INTERNAL PROPPING SYSTEMS SHALL BE CONSIDERED BY THE SURFACE "SUBJECT TO THE SOIL LAYERS & AS PER LOCAL AUTHORITY REQUIREMENTS ".
5-12. THE CONTRACTOR SHALL SUBMIT AN INSURANCE POLICY, APPROVED BY THE LOCAL CONTRACTOR AND TO SUBMIT FOR REVIEW AND ACCEPTANCE BY THE ENGINEER.
MUNICIPALITY, COVERING ALL LOCAL MUNICIPALITY REQUIREMENTS PRIOR TO WORK SELECTION OF GROUND ANCHOR INCLINATION General Notes:
6-5. THE CONTRACTOR SHALL SUBMIT WITH HIS TENDER THE FOLLOWING INFORMATION FOR
COMMENCEMENT. THE CONSIDERATION OF THE ENGINEER: SHALL CONSIDER THE LOCATION OF SUITABLE ROCK FORMATIONS, THE PRESENCE OF 1. DO NOT SCALE FROM THIS DRAWING.
5-13. ALL PILES TO HAVE A DEPTH AS SHOWN ON THE DRAWINGS AND AS RECOMMENDED BY THE BURIED UTILITIES OR OTHER GEOMETRIC CONSTRAINTS, AND CONSTRUCTABILITY OF THE 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
SOIL INVESTIGATION REPORT. HOWEVER, IT IS THE RESPONSIBILITY OF THE CONTRACTOR - DETAILED CONSTRUCTION SEQUENCE FOR AND TEMPORARY SHORING WALL
ANCHOR DRILLHOLES. GROUND ANCHORS SHALL BE LOCATED WITH AN ANGLE OF NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
TO ASCERTAIN THE DEPTH OF EACH & EVERY PILE BY CALCULATIONS BASED ON THE SOIL EXCAVATION AND LATERAL SUPPORT (ELS) WORKS INCLUDING THE TEMPORARY ROAD BY THE ENGINEER.
DIVERSION WORKS AND THE REMOVAL OF SHORING IF ANY; INCLINATION BELOW HORIZONTAL BETWEEN 15° MINIMUM AND 45° MAXIMUM AND TO
INVESTIGATION REPORT AND ON HIS OWN INVESTIGATION/FINDINGS DURING EXECUTION OF 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
THE PILING WORKS AND TO REPORT ALL DISCREPANCIES TO THE ENGINEER. - DEWATERING SYSTEM DESIGN AND THE LOCAL PUMPING TEST DESIGN SHOWING THE MINIMIZE THE EASEMENT REQUIRED; SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 - THE CONTRACTOR SHALL DEMONSTRATE THAT ANY DEWATERING FOR THE EXCAVATION AT SITE.
5-14. PILING WORKS CAN COMMENCE ONLY AFTER ALL TEST RESULTS PERFORMED ON THE LOCATIONS OF PUMPING WELLS, MONITORING WELLS AND TESTING SEQUENCES;
PRELIMINARY TEST PILES ARE REVIEWED AND APPROVED BY THE ENGINEER. - TOE STABILITY CHECK FOR TEMPORARY SHORING WALL; AND SUBSEQUENT SUBSTRUCTURE CONSTRUCTION WORKS WILL NOT CAUSE EXCESSIVE 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
5-15. THE CONTRACTOR SHOULD PROVIDE THE NECESSARY ADDITIVES AND - DESIGN CALCULATION OF TEMPORARY SHORING WALL AND ELSE WORKS WITH SETTLEMENT IN ADJACENT AREAS. IN ANY CASE, THE GROUNDWATER DRAWDOWN AND RELEVANT SECTIONS OF THE SPECIFICATION.

SUPERPLASTICIZERS IN THE CONCRETE MIX IN ORDER TO ACHIEVE THE REQUIRED NECESSARY ANALYSIS ON MOVEMENT OF SHORING WALL DUE TO OUTSIDE THE SITE SHALL BE PROPOSED BY THE CONTRACTOR AS PART OF THE
STRENGTH & DURABILITY CRITERIA. INSTALLATION, BRACED EXCAVATION AND DEWATERING AND ASSESSMENT TO DEWATERING SYSTEM DESIGN FOR REVIEW BY THE ENGINEER AND SHOULD
THE EFFECTS ON ADJACENT STRUCTURES, UTILITIES AND FACILITIES
5-16. DEWATERING CAN BE SWICHED OFF AFTER 28 DAYS FROM CASTING THE GROUND
(WHERE APPLICABLE);
DEMONSTRATE THE ASSOCIATED EFFECT ON ADJACENT GROUND AND STRUCTURES IS
FLOOR SLAB AND SHALL BE APPROVED BY THE ENGINEER. MINIMAL. THE GROUNDWATER DRAWDOWN OUTSIDE THE EARTH RETAINING WALL SHALL
- STABILITY CHECK FOR THE SHORING WALL AGAINST SLIDING, OVERTURNING AND UPLIFTING;
5-17. DESIGN SHOULD BE VERIFIED AGAINST FINAL CONDITIONS, THE CONTRACTOR SHOULD - CHECKING ON THE GEOTECHNICAL CAPACITY AND STRUCTURAL STRENGTH OF THE PILES;
BE MONITORED BY STANDPIPES/PIEZOMETERS DURING THE CONSTRUCTION PERIOD. IF
SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE FABRICATIONS. ANY ABNORMAL GROUNDWATER DRAWDOWN IS NOTED, CONTINGENCY MEASURE SUCH AS
7 - DESIGN CALCULATION OF PILING WORKS WITH NECESSARY ANALYSIS ON ANTICIPATED
5-18. PILING SUB-CONTRACTOR SHOULD SUBMIT FULL SET OF SHOP DRAWINGS AND
SETTLEMENT AND MOVEMENT OF PILING , AND ASSESSMENT TO THE EFFECTS ON THE RECHARGE WELLS WHICH SHALL BE PROPOSED BY THE CONTRACTOR AND AGREED WITH
CALCULATIONS FOR PILING WORKS FOR ENGINEER'S AND AUTHORITIES APPROVAL. PILING THE ENGINEER SHALL BE CARRIED OUT BY THE CONTRACTOR ON HIS OWN EXPENSE.
PROPOSED STRUCTURES, ADJACENT EXISTING STRUCTURES, UTILITIES AND FACILITIES
WORKS CAN COMMENCE ONLY AFTER GETTING THE REQUIRED APPROVALS.
(WHERE APPLICABLE);
5-19. CONTRACTOR SHALL DETERMINE THE CONCRETE STRENGTH AND REINFORCEMENT DETAILS 6-6. ASSUMPTIONS ON THE BOUNDARY CONDITIONS AND INTERFACING REQUIREMENTS SHALL BE
OF THE PRELIMINARY TEST PILES FOR ENGINEER'S APPROVAL. - CAL PUMPING TEST TO VERIFY THE HYDRAULIC CUT-OFF OF THE SHORING WALL SHALL
SPECIFIED AND VERIFIED WITH THE ENGINEER. IN PARTICULAR THE SURCHARGE/EXTERNAL BE DESIGNED AND CARRIED OUT PRIOR TO BASEMENT EXCAVATION. AT LEAST 3 LOCATIONS
5-20. ALL PILES SHALL BE DESIGNED TO RESIST A HORIZONTAL FORCE OF AT LEAST 5% OF THE FORCES SHALL BE CLEARLY STATED. CO-ORDINATION AMONGST THE SEQUENCE OF EXCAVATION,
VERTICAL LOAD. (U.N.O.) PILING, AND SHORING CONSTRUCTION SHALL BE INDICATED. IN THE VICINITY NEXT TO THE SHORING WALL SHALL BE SELECTED BY THE ENGINEER TO
6-7. THE CONTRACTOR'S PROPOSAL OF THE SHORING WALL AND ELSE WORKS SHALL CARRY OUT LOCAL PUMPING TESTS. THE TESTING ZONE OF EACH PUMPING TEST SHALL
5-21. FOR MORE INFORMATION AND REQUIREMENTS REFER TO SPECIFICATIONS.
COMPLY WITH THE FOLLOWING MINIMUM CRITERIA: COVER AT LEAST 5% OF THE PERIMETER OF THE SHORING WALL. THE SPACING OF THE
- THE INDUCED VIBRATION ON ADJACENT STRUCTURES/UTILITIES DUE TO THE OBSERVATION WELLS WITHIN THE BASEMENT AND STANDPIPES/PIEZOMETERS OUTSIDE THE
6 5-22. ALL WORKING AND NON WORKING TESTED PILES SHOULD BE CHOSEN BY THE CONSULTANT
ENGINEER CONSTRUCTION OF THE SHORING WALL AND ELS WORKS SHALL NOT BE MORE BASEMENT SHOULD NOT EXCEED 20m ALONG THE WALL PERIMETER.
THAN15mm/s; - TIE BACK / ANCHORS SHOULD BE TESTED IN ACCORDANCE WITH THE SPECIFICATIONS.
5-23. THE CONCRETE FOR PILES SHALL BE AS PER PROJECT SPECIFICATIONS. -CONCRETE
MIX DESIGN DETAILS & TRIAL MIX TEST RESULTS SHALL BE SUBMITTED TO ENGINEER FOR IMPORTANT NOTES 6-8. THE CONTRACTOR'S PROPOSAL OF ENABLING WORKS SHALL COMPLY WITH THE FOLLOWING 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
APPROVAL. MINIMUM CRITERIA: - AUTHORITY APPROVAL 0 17.08.2017 NS
(a) THE CONTRACTOR MUST OBTAIN ALL REQUIRED NOCS' FROM RTA AND ALL RELEVANT
5-24. THE TOTAL LENGTH OF THE PILE IS THE RESPONSIBILITY OF THE CONTRACTOR SO THAT - THE INDUCED VIBRATION ON ADJACENT STRUCTURES/UTILITIES DUE TO THE Purpose of Issue Rev. Date Appoved
AUTHORITIES FOR ENABLING WORKS.
THE PILE CAN ACHIEVE THE REQUIRED LOAD CARRYING CAPACITY & SATISFY THE CONSTRUCTION OF SHORING AND PILING SHALL NOT BE MORE THAN 15mm/s; Client:
LOADING TEST. DETAILS OF PILE LENGTH TO BE SUBMITTED TO CONSULTANTS FOR - THE AVERAGE COMPRESSIVE STRESS OF CONCRETE PILE SHAFT IMPOSED BY WORKING
APPROVAL AS PER SOIL INVESTIGATION REPORT.
LOAD SHALL NOT EXCEED 33% OF THE DESIGN GRADE STRENGTH OF THE CONCRETE.
5-25. ALL PILES SHALL BE CAPABLE OF CARRYING THE WORKING LOADS INDICATED IN THE
5 PILE SCHEDULES, ALLOWABLE VERTICAL DISPLACEMENT (SETTLEMENT) SHALL BE IN STANDARD CONDITIONS OF NOC - THE CAPACITY OF THE SOIL/ROCK FOR BEARING, BOND OR FRICTION SHALL POSSESS
MINIMUM FACTORS OF SAFETY OF 2.5 UNDER COMPRESSION AND TENSION MEYDAN L.L.C
ACCORDANCE WITH SPECIFICATION ALLOWABLE HORIZONTAL DISPLACEMENT NOT THE METHOD OF SHORING THE BASEMENT EXCAVATION IS APPROVED SUBJECT TO THE FOLLOWING: P.O. Box 9305, Dubai , UAE.
EXCEED 5mm. OF PERMANENT DEFORMATION AT WORKING LOADS. RESPECTIVELY. T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
1. TRIAL PITS MUST BE TAKEN BY CAREFUL HAND EXCAVATION TO LOCATE THE EXISTING - CONE FAILURE SHALL BE CHECKED FOR TENSION PILE SOCKETTED INTO ROCK. THE Principal Consultant:
SERVICES BEFORE BORING OF SECANT PILES THE TRIAL PITS SHALL BE RESTRICTED TO MINIMUM FACTOR OF SAFETY AGAINST CONE FAILURE SOLELY BY SUBMERGED WEIGHT OF
PILE TESTING ROCK/SOIL MASS SHALL BE 1.1;
UNMADE AREAS AROUND THE PLOT LINE AS FAR AS POSSIBLE.
-LOAD TESTING OF PILES SHALL BE CARRIED OUT IN ACCORDANCE WITH SPECIFICATIONS, AND AS FOLLOWS : IN THE EVENT OF EXISTING PAVED AREAS AROUND THE PLOT LINE REQUIRING EXCAVATION FOR - THE ANTICIPATED ABSOLUTE SETTLEMENT, ANGULAR DISTORTION AND LATERAL MOVEMENT abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

LOCATING SERVICES AND INSERTION OF PILES, A SEPARATE ROAD CUTTING NOC OF THE SHORING WALL AND PILING SHALL GENERALLY NOT EXCEED 25mm, 1/500 AND 30mm www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1

WILL HAVE TO BE OBTAINED FROM RTA BEFORE ANY CUTTING IS MADE.


RESPECTIVELY, UNLESS SUCH SETTLEMENT OR LATERAL MOVEMENT CAN BE TOLERATED PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 1) STATIC AXIAL COMPRESSION LOAD TEST BY THE PROPOSED STRUCTURES AND HAS MINIMAL ADVERSE EFFECT ON THE ADJACENT Sub-Consultant:
NON WORKING TEST PILES, "250% ALLOWABLE LOAD" STRUCTURES, UTILITIES AND FACILITIES (WHERE APPLICABLE);
2. ALL EXISTING SERVICES AND ROAD STRUCTURES WILL HAVE TO BE PROTECTED AT ALL TIMES - NO BENEFICIAL GROUNDWATER UPLIFT FORCE SHALL BE CONSIDERED TO DEDUCE THE
PILE TEST TYPE ALLOWABEL LOAD TEST LOAD PILE PILE AND ANY DAMAGES TO THEM WILL BE TREATED AS VIOLATION OF LAW No.2/94 AND LOCAL
TYPE "kN" "kN" DIAMETER "mm" LENGTH "m" COMPRESSION LOAD OF THE PILE;
ORDER No. 84/94 ON THE PART OF BUILDING CONTRACTOR, AND WILL BE TREATED AS SUCH.
- THE MINIMUM FACTOR OF SAFETY OF THE SHORING WALL AGAINST SLIDING, OVERTURNING
IN ADDITION THE REIMBURSEMENT OF ALL COSTS OF REPAIRS WILL BE TO THE OWNER'S ACCOUNT.
TYPE 4
STATIC AXIAL COMPRESSION NON
4,885 12,215 750 24.00 AND UPLIFT SHALL BE 1.50
WORKING LOAD TEST
3. THIS NOC IS ISSUED AS A GENERAL TECHNICAL GUIDANCE TO THE OWNER AND DUBAI MUNICIPALITY - THE MAXIMUM CRACK WIDTH IN PILES SHALL NOT EXCEED 0.2mm Project Name:
BEARS NO RESPONSIBILITY TOWARDS ANY COLLAPSE OF SIDE WALLS OR ANY
3 TO ANY PARTY WHATSOEVER.OTHER MISHAPS OCCURRING 6-9. DESIGN OF THE SHORING WALL, ELS WORKS AND PILING SHALL COMPLY WITH ALL DUBAI WATER CANAL
2) STATIC AXIAL COMPRESSION LOAD TEST
LOCAL REGULATIONS/CODES IN DUBAI. SAFA A
WORKING TEST PILES, "150% ALLOWABLE LOAD"
1% OF THE TOTAL NUMBER OF PILES TO BE TESTED NO OBJECTION FROM AUTHORITIES N.O.C SUBJECT TO THE FOLLOWING 6-10. THE PROPOSED SHORING WALL AND ELS WORKS SHALL BE CAPABLE TO RETAIN THE LEVEL DUBAI-UAE
3) STATIC AXIAL TENSION LOAD TEST DIFFERENCE AND COPE WITH THE CONSTRUCTION ACTIVITIES UNDERTAKEN IN THE NEARBY.
1. THE CONTRACTOR MUST CARRY OUT THE WORK CAREFULLY TO AVOID DAMAGE OF EXISTING SERVICES. THE DESIGN SHALL SATISFY BOTH ULTIMATE LIMIT STATE AND SERVICEABILITY LIMIT STATE
WORKING TEST PILES, "150% ALLOWABLE LOAD" Project Description:
ONE PILE TO BE TESTED 2. PROGRAME OF THE ABOVE WORKS MUST BE COORDINATED WITH DUBAI MUNICIPALITY, CONTRACTOR IN ACCORDANCE WITH CIRIA REPORT NO. C580 UNLESS OTHERWISE AGREED BY THE ENGINEER. MIXED USE DEVELOPMENT
AND CONSULTANT WITHIN THE AREA.
PILE ALLOWABEL LOAD TEST LOAD PILE PILE 3. F.I.C DETAILS TO BE RECONFIRMED WITH DUBAI MUNICIPALITY DRAINAGE & IRRIGATION DEPARTMENT
6-11. THE SHORING WALL AND ELS WORKS SHALL BE DESIGNED TO SUPPORT THE SURCHARGE OF (RETAIL & RESIDENTIAL)
TEST TYPE
TYPE "kN" "kN" DIAMETER "mm" LENGTH "m" BEFORE FINALISING THE INTERNAL PIPE WORK.
MINIMUM 20 kPa. THE SURCHARGE CONDITION SHALL BE DESIGNED BY THE CONTRACTOR TO PLOT 01 / 3435338
2 THE APPROVAL OF THE ENGINEER AND DULY INCORPORATED IN HIS DESIGN OF THE EARTH BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
STATIC AXIAL TENSION 4. TEMPORARY HOARDING OUT WITH THE BUILDING LINE TO BE AGREED WITH DUBAI MUNICIPALITY RETAINING WALL.
TYPE 7a 1500 2,250 900 28.00 AND CONSULTANT.
WORKING LOAD TEST Drawing Title:
5. THE CONTRACTOR IS RESPONSIBLE TO PROTECT EXISTING SEWERAGE/ DRAINAGE/IRRIGATION/HOUSE 6-12. CONTRACTOR'S ATTENTION IS DRAWN TO THE POSSIBLE UNDERGROUND OBSTRUCTION
4. HIGH STRAIN DYNAMIC LOAD TEST . CONNECTION LINE. ANY DAMAGED TO THESE SERVICES WILL BE CHARGED TO CONCERN PARTY. SUCH AS FOUNDATIONS OF OLD STRUCTURES. METHOD OF OVERCOMING UNDERGROUND
WORKING TEST PILES ………. 5% WORKING PILES OF THE TOTAL NUMBER FOR EACH PLOT. 6. LEVEL OF OUR EXISTING SERVICES ARE TO BE CONFIRMED BEFORE COMMENCING THE SHORING OBSTRUCTION SHALL BE PROPOSED BY THE CONTRACTOR TO THE APPROVAL OF THE ENGINEER STRUCTURAL GENERAL NOTES - 02
5. LOW STRAIN INTEGRITY TEST (PULSE ECHO OR SONIC ECHO). AND ANCHORING OPERATIONS. 6-13. CONSTRUCTION RECORDS SHALL BE SUBMITTED TO THE ENGINEER FOR RECORD AT TIMING
WORKING TEST PILES ………. 100% WORKING PILES OF THE TOTAL NUMBER OF EACH PLOT. AGREED BY THE ENGINEER. DETAILS OF SUBMISSION SHALL BE APPROVED BY THE ENGINEER
PRIOR TO CONSTRUCTION OF WORKS. Scale Drawn Checked Approved Size
6. CROSSHOLE SONIC LOGGING INTEGRITY TEST . AA MA NS
1 WORKING TEST PILES ………. 10% WORKING PILES OF THE TOTAL NUMBER OF EACH PLOT. 6-14. THE DESIGN OF THE SHORING WALL, ELS WORKS AND PILING WORKS SHOULD BE SUBMITTED N.T.S A1
TO THE LOCAL GOVERNMENT AUTHORITIES IN DUBAI FOR APPROVAL PRIOR TO WORKS 26.05.2016 24.08.2017 24.08.2017
COMMENCEMENT, THE CONTRACTOR SHALL BE RESPONSIBLE TO RESPONSE TO ANY QUERIES Drawing Number Rev.
FROM THE GOVERNMENT AUTHORITIES AND TO THEIR SATISFACTION/APPROVAL. 14011603-01-01-00-SG0003 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
8. ABBREVIATIONS 9. GRAPHIC SYMBOLS & REFERENCES KEYS 10. DRAWINGS ORGANIZATIONS:
AB - ADDITIONAL BOTTOM REINFORCEMENT
ADD - ADDITIONAL - REINFORCED CONCRETE
ALT - ALTERNATIVE
ARB - ARCH BEAM
AT - ADDITIONAL TOP REINFORCEMENT - BLINDING 10-1. DRAWING NUMBERING SYSTEM
B - BEAM - BREAK LINE
BLK - REINFORCED BLOCK WORK IN GENERAL CASE THE DRAWING NUMBER FOR EACH SHEET CONSISTS OF THE FOLLOWING: N
10 KEY PLAN
BOTT (B) - BOTTOM
- SLOPE
BR
BRK
-
-
BRACING
BRICK WALL 14011603 - 00 - 01 - S0000
BW - BOTH WAYS
- OPENING / SLEEVES IN THE STRUCTURAL ELEMENT
C - CONCRETE COLUMN
DRAWING GROUP NUMBER
CA - CANTILEVER BEAM
DISCIPLINE CODE
C/C - CENTERS
CHQ - CHECKERED PLATE - COMPACTED SOIL
CIP - CAST-IN-PLACE BUILDING NUMBER
9 PLOT CODE
CL - CENTER LINE
PROJECT NUMBER
DIA/Ø - DIAMETER
DWG - DRAWING - STRUCTURAL LEVEL (ELEVATION / SECTION)
DIAPH - DIAPHRAGM 10-2. BUILDING NUMBER General Notes:
DET - DETAIL
- GROUND LEVEL (ELEVATION / SECTION) 1. DO NOT SCALE FROM THIS DRAWING.
ALL BUILDINGS ARE CLASSIFIED ACCORDING TO THE FOLLOWING:
EL - EXISTING LEVEL 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
EF - EACH FACE 00 = GENERAL NOTES AND STANDARD DETAILS, BASEMENT AND GROUND BY THE ENGINEER.
EW - EACH WAY 01 = BUILDING 01
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
(E.J.) - EXPANSION JOINT - STRUCTURAL SLAB ON PLANS 02 = BUILDING 02 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
ELEV - ELEVATION 03 = BUILDING 03
04 = BUILDING 04 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
FL - FOUNDATIONS LEVEL ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

FFL - FINISHED FLOOR LEVEL - SLAB THICKNESS ON PLANS 280 AND RELEVANT SECTIONS OF THE SPECIFICATION.

FGL - FINISHED GROUND LEVEL


G - GRADE OF STEEL BOLT / ANCHOR - WALL THICKNESS ON PLANS (250) 10-3. DISCIPLINE CODE
GB - GROUND BEAM
GND - GROUND ALL DRAWINGS ARE CLASSIFIED ACCORDING TO THE FOLLOWING DISCIPLINES:
HB - HIDDEN BEAM G = GENERAL DRAWINGS
HCS - HOLLOW CORE SLAB - STEP IN LEVEL ON PLANS A = ARCHITECTURE
7
HR/HL - HORIZONTAL S = STRUCTURAL ENGINEERING
(&) - AND M = MECHANICAL ENGINEERING
(@) - AT - SETTING OUT POINT E = ELECTRICAL ENGINEERING
(%) - PERCENT I = INTERIOR DESIGN
(±) - PLUS/MINUS L = LANDSCAPE
LB - LINTED BEAM
- DETAIL MARK / REFERENCE
C = CIVIL
LVL - LEVEL
10-4. DRAWING GROUP NUMBER
M - DIAMETER OF BOLT / ANCHOR
6 MAX - MAXIMUM
MIN - MINIMUM STRUCTURAL DRAWINGS ARE ORGANIZED INTO THE FOLLOWING
SECTION
GROUPS:
NTS - NOT TO SCALE
- SECTION REFERENCE 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
DRAWING No. SC1000 = COLUMN LAYOUT
P - PILE AUTHORITY APPROVAL 0 17.08.2017 NS
PB - PRE-STRESSED BEAM SF1000 = FRAMING LAYOUT Purpose of Issue Rev. Date Appoved
PC - PILE CAP SR1000 = REINFORCEMENT LAYOUT Client:
(P.C.) - PLAIN CONCRETE (BLINDING) S5000 = DETAILS
PL - STEEL PLATE - REINFORCEMENT DETAILS
S6000 = SCHEDULES
PLc - PLANTED COLUMN F1
5 PD - PEDESTAL COLUMN FAR FACE (OUTER LAYER) --- F1
PS - PUNCHING SHEAR FAR FACE (SECOND LAYER) --- F2 F2 MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
PT - POST-TENSIONING SLAB NEAR FACE (OUTER LAYER) --- N1 T: +9714 3270000 F: +9714 3270007
N1 E: info@dubairacingclub.com W: www.dubairacingclub.com
R - MILD STEEL NEAR FACE (SECOND LAYER) --- N2 Principal Consultant:
N2
(R.C.) - REINFORCED CONCRETE BOTTOM FACE (LOWER LAYER) --- B1
RFT - REINFORCEMENT
BOTTOM FACE (SECOND LAYER) --- B2 T1 T2
RW - RETAINING WALL
S - WELDING SIZE TOP FACE (UPPER LAYER) --- T1 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
SB - STRAP BEAM TOP FACE (SECOND LAYER) --- T2 Hassanicor Building, 6th Floor, Al Barsha 1
SB - STEEL BEAM PO Box 54115 Dubai, UAE
B1 B2 P: +971 4 3997758 F: +971 4 3997759
4 SC - STEEL COLUMN Sub-Consultant:
SG - STEEL GIRDER
S.O.G - SLAB ON GRADE DISTRIBUTION LENGTH
SOL - SETTING OUT LINE
SOP - SETTING OUT POINT
SQ - SQUARE TOTAL NO. OF BARS
4000
SSL - STRUCTURAL SLAB LEVEL (20)
STG - STAGGERED
T16@200 (AT)

Project Name:
STIFF - STIFFENER PLATE
L=4.00m

4000
(20)

3 T - TOP DUBAI WATER CANAL


T - HIGH TENSILE STEEL T16@200mm (AT)
SAFA A
TB - TIE BEAM L=4.00m
THK - THICKNESS DUBAI-UAE
TL - TOP LEVEL
T.O.C - TOP OF CONCRETE Project Description:
T.O.B - TOP OF BEAM
T.O.P - TOP OF PARAPET *C32/40 MIXED USE DEVELOPMENT
T.O.S - TOP OF STEEL - CONCRETE STRENGTH CUBE STRENGTH OF CONCRETE (RETAIL & RESIDENTIAL)
TRB - TRANSFER BEAM
CYLINDER STRENGTH OF CONCRETE
PLOT 01 / 3435338
2 TRG - TRANSFER GIRDER BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
TYP - TYPICAL
Drawing Title:
U.N.O - UNLESS NOTED OTHERWISE - SLABS SPANS AND TYPE

VR/VL - VERTICAL
THK. THK. THK. STRUCTURAL GENERAL NOTES - 03
THK.

W - WALL
WF - WITH FLOOR CANTL.
WS - WITH STAIR
ONE WAY SLAB TWO WAY SLAB CANTILEVER SLAB Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0004 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
11. POST-TENSIONED CONCRETE NOTES

11-1. GENERAL
11-8. MISCELLANEOUS 11-23. ADDITIONAL CONCRETE REQUIREMENTS FOR POST TENSIONING
11-1-1. ALL POST-TENSIONING WORKS SHALL BE CARRIED OUT IN ACCORDANCE
WITH ACI 318-11 STRUCTURAL USE OF CONCRETE AND TR-43
a) NO DRILLING OR BREAKING OUT OF THE SLAB SHALL BE PERMITTED WITHOUT A. ALL CONCRETE TEST CYLINDERS SHALL BE SITE CURED UNDER CONDITIONS
11-1-2.
- FORMWORK SHALL BE DESIGNED TO SUPPORT THE REACTIONS DURING PRIOR APPROVAL. CONSISTENT WITH THE CONCRETE POUR.
STRESSING. N
10 B. MAXIMUM SHRINKAGE STRAIN AT 56 DAYS, SHALL BE 600x10-6 MICROSTRAIN.
KEY PLAN
b) (i) SHOULD SMALL FIXINGS BE REQUIRED FOR THE SUSPENSION OF SERVICES,
DRILLING INTO THE CONCRETE SHALL BE BY STANDARD 'MASONRY BIT' TYPE DRILLS ONLY
AND SHALL ONLY BE PERMITTED SUBJECT TO APPROVAL. C. TO PREVENT DAMAGE TO STRESSING TENDONS AND REINFORCEMENT, CONCRETE
11-2. STRAND PROPERTIES
PUMP LINES SHALL BE ADEQUATELY RESTRAINED AND SUPPORTED ON STOOLS
OR TIMBER BLOCKS.
11-2-1. ALL STRANDS SHALL COMPLY WITH ACI 318-11 SEVEN WIRE STEEL STRAND FOR
PRESTRESSED CONCRETE. (ii) ALL DUCTS SHALL BE FULLY GROUTED AND DUCT POSITIONS PERMANENTLY MARKED D. SLURRY USED TO LUBRICATE CONCRETE PUMP LINES SHALL NOT BE
ON SOFFITS BEFORE ANY DRILLING COMMENCES. UNDER NO CIRCUMSTANCES SHALL ANY USED IN ANY STRUCTURAL MEMBER.
STRAND TYPE : SUPER DRILL BIT OR CORE BE USED WHERE THIS CAN PENETRATE STEEL (i.e. DIAMOND DRILL
BIT OR DIAMOND CORE)
NOMINAL DIAMETER : 12.7 mm
9 11-24. ADDITIONAL REINFORCEMENT REQUIREMENTS FOR POST TENSIONING
NOMINAL AREA : 99 mm2
TENSILE STRENGTH : 1770 N/mm2 A. TOP REINFORCEMENT SHALL NOT BE LAID UNTIL AFTER TENDONS
11-9 SUBMIT ALL TEST CERTIFICATES, CALCULATIONS AND WORKSHOP DRAWINGS TO
HAVE BEEN PLACED.
MINIMUM BREAKING L0AD : 184 kN THE ENGINEER PRIOR TO CONSTRUCTION.
YOUNG'S MODULUS : 195GPa General Notes:
11-10. ALL STRESSING EQUIPMENT AND GAUGES SHALL POSSESS CURRENT CALIBRATION 11-25. EXTERNAL STRESSING POCKET TREATMENT NOTES
MAX. RELAXATION AT 1000 Hrs : 2.5 % 1. DO NOT SCALE FROM THIS DRAWING.
(AT 80% Pult) CERTIFICATES AVAILABLE TO THE CONSULTING ENGINEER UPON REQUEST.
11-25-1. ALL STRESSING EQUIPMENT AND GAUGES SHALL POSSESS CURRENT CALIBRATION 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
CERTIFICATES AVAILABLE TO THE CONSULTING ENGINEER UPON REQUEST. NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
11-3. TENDON DESIGN PARAMETERS 11-11. TENDONS SHALL BE LOCATED IN ACCORDANCE WITH THE DRAWINGS TO A 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
VERTICAL TOLERANCE OF +/- 5.0mm. A. CUT BACK STRAND ENDS AS FAR AS POSSIBLE. SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 11-3-1. THE FRICTION PARAMETERS ASSUMED FOR THE DESIGN ARE AS FOLLOWS: AT SITE.

11-12. TENDONS SHALL BE SECURELY FIXED IN POSITION AT MAXIMUM 1200mm CTS. B. DEGREASE AND WIRE BRUSH STRAND ENDS AND ANCHOR POCKET AND 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
SLAB TENDON ALONG THE LENGTH. ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
ALLOW TO DRY. AND RELEVANT SECTIONS OF THE SPECIFICATION.
FRICTION COEFFICIENT u = 0.20/radian
WOBBLE FACTOR k = 0.002/m 11-13. TENDONS ARE GENERALLY TO HAVE A PARABOLIC PROFILE WITHIN SPANS UNLESS C. EPOXY COAT STRAND ENDS AND ANCHOR.
WEDGE DRAW-IN l = 6.0mm NOTED OTHERWISE, AND SHALL CONFORM TO GIVEN PROFILE POINTS.
D. FILL ANCHOR POCKET WITH NON-SHRINK GROUT
11-4. TENDON SIZES (MASTERFLOW 870 BY MDT OR SIMILAR) FLUSH WITH SLAB.
11-14. TENDON HEIGHTS GIVEN ON DRAWINGS ARE MEASURED FROM THE SOFFIT
OF BEAM AS FOLLOWS: E. IMMEDIATELY COVER GROUTED POCKET WITH PLASTIC COVER SECURELY TAPED
11-4-1. ALL TENDONS SHALL BE FORMED FROM THE STRANDS WITH THE PROPERTIE
7 AROUND ALL FOUR EDGES TO PROMOTE MOIST CURING OF GROUT.
STATED IN NOTE 2 ABOVE.
AT ANCHORAGES :- TO CENTERLINE OF ANCHOR
11-4-2. ALL TENDONS SHALL BE VSL MULTISTRAND SYSTEM UNLESS OTHERWISE F. LEAVE PLASTIC COVER ON FOR 7 DAYS MINIMUM.
NOTED ON THE TENDON LAYOUT DRAWINGS, OR EQUIVALENT TO THE ELSEWHERE :- TO UNDERSIDE OF DUCT.
ENGINEER'S APPROVAL. G. REMOVE PLASTIC AND APPLY ACRYLIC WATERPROOFING MEMBRANE, COMPATIBLE
11-15. TENDON PROFILES SHALL HAVE PRECEDENCE OVER OTHER WITH THE SPECIFIED PAINT SYSTEM, EXTENDING PAST THE GROUTED POCKET TO
11-5. TENDON SET OUT REINFORCEMENT AND SERVICE CONDUITS. THE EXPOSED SLAB EDGE.

11-16. STRESSING PROCEDURE: H. ALLOW ACRYLIC MEMBRANE TO CURE BEFORE APPLICATION OF SPECIFIED PAINT
11-5-1. ALL TENDONS SHALL BE SET OUT TO THE POSITION AND PROFILES SPECIFIED SYSTEM OVER.
ON THE TENDON LAYOUT DRAWINGS.
6 i) STRESS EACH INDIVIDUAL STRAND OF ALL TENDONS TO 25% U.T.S AT APPROX. 24HRS.
(FCP=7/9MPa MINIMUM) AFTER COMPLETION OF POUR.
11-5-2. GENERAL: DESIGN IN ACCORDANCE WITH BS 8110-1997, CLASS 3 MEMBER, IMPORTANT:
WITH A MAXIMUM CRACK WIDTH OF 0.2mm.
ii) FULLY STRESS TENDONS WHEN CONCRETE ATTAINS F'c=22/30 MPa.
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
a) CREEP COEFFICIENT =2.72 FOR 12.7mm DIA. STRANDS (MONO), F'c=25/35MPa. FOR 15.2mm DIA.
1. THE FINAL DESIGN & DETAILS OF PT SLABS ARE THE SOLE RESPONSIBILITY OF THE AUTHORITY APPROVAL 0 17.08.2017 NS
b) SHRINKAGE STRAIN = 600x10 STRANDS OR 12.7mm DIA. STRANDS (MULTI) CONTRACTOR PT SPECIALIST . HOWEVER , THE FINAL DESIGN AND THE DETAILING
-6 Purpose of Issue Rev. Date Appoved
c) YOUNG'S MODULUS OF CONCRETE = 29000 MPa SHALL BE SUBMITTED TO THE ENGINEER AND LOCAL AUTHORITY FOR APPROVAL.
iii) JACK TENDONS TO 85% U.T.S. AND LOCK OFF. Client:
d) ULS DESIGN LOAD SHALL BE = 1.4DL + 1.6LL + EFFECTIVE
PRESTRESS FORCE
iv) JACK CENTRAL TENDONS FIRST AND WORK PROGRESSIVELY OUTWARDS 2. THE CONTRACTOR PT SPECIALIST HAS TO CONSIDER ALL LOADS AND STRAINING
5 11-5-3. ALL VERTICAL PROFILES SHALL BE MEASURED FROM THE SLAB TOP LEVEL ON EACH SIDE. (ALTERNATING). ACTION GIVEN IN THE STRUCTURAL DRAWINGS. IN ADDITION TO THE LATERAL
TO THE CENTERLINE OF THE TENDON DUCT EXCEPT AT STRESSING AND REACTIONS THAT SHALL BE EXTRACTED FROM 3D STRUCTURAL MODELS. MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
DEAD END ANCHORAGES. (SEE NOTE 6 BELOW) T: +9714 3270000 F: +9714 3270007
11-17. TENDON POSITION SHALL BE MARKED ON SLAB SOFFIT BY USE OF EMBEDDED E: info@dubairacingclub.com W: www.dubairacingclub.com
PLASTIC BUTTONS AT GRID AND MID - GRID LOCATIONS AND THE ALIGNMENTS 3. THE MAXIMUM LOND TERM DEFLECTION FOR CANTILIVER SLABS SHALL NOT EXCEED Principal Consultant:
SHALL BE PAINTED ON SLAB SOFFIT. PROPOSED ARRANGEMENT TO BE L/300 OR 20mm WHICH IS LESSER.
11-6. ANCHORAGES SUBMITTED FOR APPROVAL.

11-6-1. ALL TENDONS SHALL HAVE ANCHORAGES AS SPECIFIED ON THE TENDON 11-18. FINAL STRESSING SHALL FIRST BE APPLIED TO BEAM/BAND TENDONS, FOLLOWED abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
4. THE MAXIMUM LOND TERM DEFLECTION AT THE MID OF SPAN SHAL NOT EXCEED www.ae-7.com
LAYOUT DRAWING. THEN BY SLAB TENDONS. L/240 OR 25mm WHICH IS LESSER. Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 11-6-2. ALL ANCHORAGES SHALL BE SET OUT TO THE POSITIONS AND OFFSETS 11-19. ALTERNATIVE STAGED STRESSING OPERATIONS WHERE REQUIRED SHALL
SPECIFIED ON THE TENDON LAYOUT DRAWINGS. Sub-Consultant:
BE NOTED.
5. THE MAXIMUM INCREMENTAL DEFLECTION SHALL NOT EXCEED L/480.
11-6-3. ALL VERTICAL OFFSETS SHALL BE MEASURED FROM THE SLAB TOP LEVEL TO 11-20. STRAND EXTENSIONS SHALL BE RECORDED FOLLOWING FINAL STRESSING FOR
THE CENTERLINE OF THE ANCHORAGE. SUBMISSION TO THE ENGINEER.
6. THE PT SPECIALIST SHALL COORDINADE WITH THE ENGINEER TO CONSIDER
11-7. DUCTS 11-21. FOLLOWING APPROVAL OF THE EXTENSIONS BY THE ENGINEER, STRAND ENDS NON-PRESTRESSING REINFORCEMENT REQUIRED DUE TO LATERAL LOADS
SHALL BE CUT OFF AND SEALED FLUSH WITH THE SURROUNDING CONCRETE "SEISMIC & WIND" AND THERMAL EFFECT AS WELL.
FACE WITH A HOMOGENEOUS CEMENT MIX.
11-7-1. ALL DUCTS SHALL BE CORRUGATED STEEL WITH A MINIMUM WALL THICKNESS Project Name:
OF 0.25 mm. DUCTS SHALL BE RIGIDLY SUPPORTED BY AN APPROVED MEANS
3
AT NOT MORE THAN 1000 mm CENTERS. NO RIBBED HIGH GRADE BARS SHALL 11-22. GROUTING OF TENDONS SHALL OCCUR WITHIN 7 DAYS OF STRESSING
APPROVAL.
DUBAI WATER CANAL
BE PERMITTED TO BE USED AS SUPPORTS. DUCTS SHALL BE SEALED. SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL NOTES - 04

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0005 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
C
L END SUPPORT C
L INTERMEDIATE SUPPORT C
L INTERMEDIATE SUPPORT C
L END SUPPORT

1/3 x L3 OR 1.25 L4
WHICHEVER IS GREATER
SPAN VARIES SPAN VARIES SPAN VARIES CANTILEVER SPAN VARIES

L1 (CLEAR SPAN) L2 (CLEAR SPAN) L3 (CLEAR SPAN) L4 (CLEAR SPAN)

SIDE BARS SIDE BARS SIDE BARS


TOP BARS (T)
A SIDE BARS
C
L OF SPAN C
L OF SPAN C
L OF SPAN N
----
10 ADD TOP BARS ADD TOP BARS TOP BARS (T) ADD TOP BARS TOP BARS (T) ADD TOP BARS KEY PLAN
35mm. MIN. (ET) (AT) (AT) (AT) TOP BARS (T)
75mm. MAX. 1/3 x L1 LCS 1/3 x L* 1/3 x L* LCS 1/3 x L* 1/3 x L* LTB
GREATER OF { 1/3 x L3
1.25 L4
12 x DIA.
DEPTH

MIN.150mm. LCS LCS LCS

9
BOTTOM BARS (B) BOTTOM BARS (B) BOTTOM BARS (B)

BOTTOM BARS (B)


ADD BOTTOM BARS ADD BOTTOM BARS ADD BOTTOM BARS
(AB)
1/8 x L1 50mm. 50mm. 1/8 x L2
(AB)
1/8 x L2 50mm. 50mm. 1/8 x L3
(AB)
1/8 x L3 50mm. 50mm.
General Notes:
50mm. 1/8 x L1
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
END STIRRUPS OVER END STIRRUPS OVER END STIRRUPS OVER END STIRRUPS OVER END STIRRUPS OVER END STIRRUPS OVER BY THE ENGINEER.
SUPPORT 1/4 L1 MIN. U.N.O. STIRRUPS BALANCE 1/4 L1 MIN. U.N.O. SUPPORT 1/4 L2 MIN. U.N.O. STIRRUPS BALANCE 1/4 L2 MIN. U.N.O. SUPPORT 1/4 L3 MIN. U.N.O. STIRRUPS BALANCE 1/4 L3 MIN. U.N.O. SUPPORT END STIRRUPS
WIDETH (S1) (S2) (S1) WIDETH (S1) S2) (S1) WIDETH (S1) (S2) (S1) WIDETH (S1) 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
TYPICAL END BAY TYPICAL INTERNAL BAY TYPICAL INTERNAL BAY ADJACENT TO CANTILEVER TYPICAL CANTILEVER

01 TYPICAL
SCALE:
GRAVITY RC. BEAM ELEVATION
N.T.S

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved

C C 2 LEGS 3 LEGS 4 LEGS 5 LEGS 6 LEGS Client:


L END SUPPORT L END SUPPORT

SPAN VARIES
5
L1 (CLEAR SPAN) MEYDAN L.L.C
03 TYPICAL STIRRUPS ARRANGEMENT P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
SCALE: N.T.S E: info@dubairacingclub.com W: www.dubairacingclub.com
A REINFORCED CONCRETE BEAM NOTES
SIDE BARS Principal Consultant:
TOP BARS (T) ----
C
L OF SPAN
ADD TOP BARS ADD TOP BARS TOP BARS SEE
NOTES: 1 TO 7 ARE TYPICAL FOR ALL BEAMS.
ADD TOP BARS abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
(ET) (AT) SCHEDULE.
35mm. MIN. (ET) www.ae-7.com
75mm. MAX. 1/3 x L1 1/3 x L* R.C. SLAB Hassanicor Building, 6th Floor, Al Barsha 1
ADDITIONAL LAYER IF CLEAR WHERE OCCURS 1.ALL DIMENSIONS ARE IN MILLIMETER, U.N.O.. PO Box 54115 Dubai, UAE
SPACING BETWEEN REBARS OF P: +971 4 3997758 F: +971 4 3997759
4
ANY LAYER EXCEED 50mm Sub-Consultant:
2.L* IS GREATER OF ADJACENT CLEAR SPAN.
12 x DIA.
DEPTH

SEE NOTE 1
SLAB THICKNESS

3.ALL TOP BARS AND BOTTOM BARS SHALL BE PLACED IN ONE LAYER
IF SPACING PERMITS.SEE TYPICAL BEAM SECTION FOR BAR SPACING
REQUIREMENTS.
T

4.PLACEMENT OF CONTINUOUS AND DISCONTINUOUS REBARS IN EACH

SEE SCHEDULE
LAYER SHALL BE IN ACCORDANCE WITH ACI 318-11M Project Name:

DEPTH
50mm. 1/8 x L1 BOTTOM BARS (B) 1/8 x L1 50mm.
SIDE BAR RECOMMENDATIONS.
3
STIRRUPS,SEE
SCHEDULE
WHERE OCCURS DUBAI WATER CANAL
5.USE END SPACING OF SHEAR REINFORCEMENT FOR ENTIRE
40mm CLEAR
CANTILEVER SPAN.
SAFA A
ADDITIONAL LAYER IF CLEAR TYP.
ADD BOTTOM BARS DUBAI-UAE
SPACING BETWEEN REBARS OF
(AB)
END STIRRUPS OVER END STIRRUPS OVER ANY LAYER EXCEED 50mm 6.WHERE GRAVITY FRAMING INTERSECTS WITH FRAME BEAMS, THE
SUPPORT 1/4 L1 MIN. U.N.O. STIRRUPS BALANCE 1/4 L1 MIN. U.N.O. SUPPORT FRAME BEAM REBAR TAKES PRECEDENCE (i.e. LOCATE IN FIRST OR
MIN. CLEAR HORIZONTAL SPACE

Project Description:
WIDETH (S1) (S2) (S1) WIDETH OUTERMOST LAYERS) U.N.O.. WHERE GRAVITY FRAMING INTERSECTS
BETWEEN BARS IS 25mm

BOTTOM BARS,
WIDTH SEE SCHEDULE SEE SCHEDULE.
OTHER GRAVITY FRAMING, THE DEEPER MEMBER REBAR TAKES MIXED USE DEVELOPMENT
PRECEDENCE OR WHERE BEAMS ARE THE SAME DEPTH,THE BEAM
WITH THE GREATEST REBAR TAKES PRECEDENCE(U.N.O.). (RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 7.WHERE TOP REINFORCING VARIES IN ADJACENT SPANS USE THE BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
GREATER VOLUME OF REINFORCING IN BOTH SPANS.
Drawing Title:
8.SEE PLANS FOR ADD'L BEAM REINFORCEMENT NOT SHOWN ON
SCHEDULE.
STRUCTURAL GENERAL DETAILS -
NOTE:
9.STIRRUP ARRANGEMENT TO BE BASED ON EXAMPLES SHOWN ON
THIS SHEET.
01
ADD TOP BARS OUTSIDE STIRRUP CAGE WHERE 10. UPTURNED BEAMS MUST BE PLACED MONOLITHICALLY FOR FULL
NOTES IN REMARKS COLUMN IN BEAM SCHEDULE. Scale Drawn Checked Approved Size
DEPTH OF BEAMS. COLUMNS SUPPORTING UPTURNED BEAMS MUST AA MA NS
1 BE POURED MONOLITHICALLY WITH BEAMS FOR FULL DEPTH OF BEAM. N.T.S A1
26.05.2016 24.08.2017 24.08.2017

02 TYPICAL GRAVITY RC SIMPLE BEAM ELEVATION 11. ADDITIONAL TOP AND BOTTOM BARS SHALL BE PLACED IN SAME
04 TYPICAL BEAM SECTION (A) Drawing Number Rev.
SCALE: N.T.S LAYER AS TOP OR BOTTOM BARS,WHERE POSSIBE.
SCALE: N.T.S 14011603-01-01-00-SG0006 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

WALL REINFORCEMENT PER


REINFORCING PLAN N
10 KEY PLAN
BEAM STIRRUP BEAM STIRRUP
.50 TOP BAR PER SCHEDULE
50.
MAX. OF Ld AND D
50.

A
---

D
9 Ld
HORIZONTAL BARS
HORIZONTAL REINFORCEMENT
BOTTOM BAR PER BEAM SCHEDULE

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

A SECTION
SCALE:
(A)
N.T.S
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

01 LINTEL
SCALE:
BEAM TYPICAL DETAILS
N.T.S

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

5
CL MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

WALL REINFORCEMENT
REINF. TO MATCH SLAB BEAM TOP REINFORCEMENT PER REINFORCING PLAN abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
DISTRIBUTION REINF. BEAM SIDE BAR PER PER BEAM SCHEDULE Hassanicor Building, 6th Floor, Al Barsha 1
STD. HOOK BEAM SCHEDULE PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 0.3L OR 1200 MIN. TYPICAL, U.N.O.
50mm MAX. Sub-Consultant:
R.C. SLAB

CONT. SLAB BOTTOM


REINF. PER PLANS
SLAB DISTRIBUTION REINF.
Project Name:
END SUPPORT BEAM BOTTOM REINF.PER
3
BEAM SCHEDULE DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


02
03 ONE
SCALE:
WAY SLAB - TYP. SECTION AT END SUPPORTS: WALLS, GIRDERS, AND BEAMS, U.N.O.
N.T.S
02 TYPICAL
SCALE:
GRAVITY BEAM TO WALL CONNECTION DETAIL
N.T.S Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0007 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

B
DUBAI MUNICIPALITY STAMP:
--- D
---
11
0.25 L1 0.5 L1 0.25 L1

BEAM 2
INDICATESPRIMARY

BEAM 2
BEAM1 ORIENTATION

0.5h

h
A N

0.5h
10 ---
KEY PLAN
C
--- LI
BEAM 1 BEAM 1 TYPICAL INTERNAL SPAN

BEAM 1 - PRIMARY BEAM


BEAM 2 - SECONDARY BEAM BEAM 1 - PRIMARY BEAM
BEAM 2 - SECONDARY BEAM
9

NOTE: General Notes:


WHERE REFT IS TO BE DETAILED CONTINUOUSLY 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


LAPS IN REFT MAY OCCUR ONLY IN SHADED AREAS SHOWN NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
PRIMARY BEAM DEEPER THAN BY THE ENGINEER.

SECONDARY BEAM PRIMARY & SECONDARY BEAMS OF 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 SAME DEPTH AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

01 BEAM
SCALE:
INTERSECTION (NO COLUMN SUPPORT)
N.T.S 02 BEAM
SCALE:
LAP LOCATIONS
N.T.S

SECONDARY BEAM REFT. - T2 SECONDARY BEAM REFT. - T2 LAP LAP

PRIMARY BEAM REFT. - T1 PRIMARY BEAM REFT. - T1

6
3000

LAP 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

PRIMARY BEAM REFT. PRIMARY BEAM REFT. -B1


5 SPLICE BAR FOR SECONDARY BEAM-B2
SECONDARY BEAM REFT. MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

A SECTION
SCALE:
(A)
N.T.S
C SECTION
SCALE:
(C)
N.T.S 03 DETAIL
SCALE:
AT STEP IN BEAM GRATER THAN 100mm.
N.T.S abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

PRIMARY BEAM REFT. - T1

PRIMARY BEAM REFT. - T1 SECONDARY BEAM REFT. - T2


Project Name:

SECONDARY BEAM REFT. - T2


3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


300 min. 300 min. (RETAIL & RESIDENTIAL)
300 min. 300 min. PLOT 01 / 3435338
2 SECONDARY BEAM REFT. - B1 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
SECONDARY BEAM REFT.
SPLICE BAR FOR SECONDARY BEAM - B2 Drawing Title:

PRIMARY BEAM REFT. PRIMARY BEAM REFT. - B1 STRUCTURAL GENERAL DETAILS -


03

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
B SECTION
SCALE:
(B)
N.T.S D SECTION
SCALE:
(D)
N.T.S
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0008 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

GRID GRID
N
10 KEY PLAN
CL OF COL. CL OF COL.
175 mm MAX TO COLUMN HOOK AT BEAM 175 mm MAX TO COLUMN HOOK AT BEAM
100 mm MAX TO COLUMN HOOK AT SLAB 100 mm MAX TO COLUMN HOOK AT SLAB

STD. HOOK AT STD. HOOK AT


TOP OF COLUMN TOP OF COLUMN T.O. SLAB
T.O. SLAB EL. SEE PLAN
EL. SEE PLAN
SPACING

SPACING
9 50 MAXIMUM BELOW THE 50 MAXIMUM BELOW THE
= S1

= S1
S1

S1
TIE

TIE
LOWEST HORIZ. REINFORCEMENT LOWEST HORIZ. REINFORCEMENT
"A"

"A"
OF ROOF OR FLOOR SLAB, TYP. OF ROOF OR FLOOR SLAB, TYP.

General Notes:
TIE SPACING = S2

TIE SPACING = S2
1. DO NOT SCALE FROM THIS DRAWING.
S2

S2
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
"H"

"H"
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
TYP., U.N.O.

TYP., U.N.O.
LAP SPLICE

LAP SPLICE
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
LCS

LCS
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
SPACING

SPACING
AND RELEVANT SECTIONS OF THE SPECIFICATION.
S1

S1
= S1

= S1
TIE

TIE
"A"

"A"
T.O. SLAB T.O. SLAB
EL. SEE PLAN EL. SEE PLAN
SPACING

SPACING
S1/2

S1/2
= S1

= S1
TIE

TIE
SPACING

SPACING
FLOOR SLAB OR R.C. BEAM, TYP.
FLOOR SLAB OR R.C. BEAM, TYP.
S1

S1
= S1

= S1
TIE

TIE

1705
"A"

"A"
7

ONE EXTRA SET OF ONE EXTRA SET OF


TIES AT BAR CRANK TIES AT BAR CRANK
TIE SPACING = S2

TIE SPACING = S2
S2

S2
"H"

"H"
6
SPACING

SPACING
S1

S1
= S1

= S1
TIE

TIE

1705
"A"

"A"
T.O. SLAB T.O. SLAB 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
EL. SEE PLAN EL. SEE PLAN
AUTHORITY APPROVAL 0 17.08.2017 NS
SPACING

SPACING
S1/2

S1/2
Purpose of Issue Rev. Date Appoved
= S1

= S1
TIE

TIE Client:
SPACING

FLOOR SLAB OR R.C. BEAM, TYP. FLOOR SLAB OR R.C. BEAM, TYP.
SPACING
TIE "A"
S1

S1
= S1
TIE

= S1
"A"

5
MEYDAN L.L.C
ONE EXTRA SET OF ONE EXTRA SET OF P.O. Box 9305, Dubai , UAE.
TIES AT BAR CRANK TIES AT BAR CRANK T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
TIE SPACING = S2

TIE SPACING = S2
S1

S2
Principal Consultant:
"H"

"H"

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com

DOWELS TO MATCH COLUMN DOWELS TO MATCH COLUMN Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
VERTICAL REINF. VERTICAL REINF. P: +971 4 3997758 F: +971 4 3997759
4
SPACING

SPACING

Sub-Consultant:
S1

TIE "A"
= S1

S1
TIE

LCS
= S1

LCS
"A"

LAP SPLICE T.O. PILE CAP OR FOOTING LAP SPLICE T.O. PILE CAP
TYP., U.N.O. EL. SEE PLAN TYP., U.N.O. EL. SEE PLAN
KICKER

KICKER
75mm.

75mm.
FOOTING DEPTH

FOOTING DEPTH
Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:
NOTES: MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
1. "A" SHALL NOT BE LESS THAN "H/6" AND THE MAXIMUM
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
COLUMN DIMENSION (WIDTH, DEPTH OR DIAMETER).
Drawing Title:

2. INTERNAL CROSS TIE SIZES AND SPACING SHALL STRUCTURAL GENERAL DETAILS -
04
04 TYPICAL ROUND IMRF CONCRETE COLUMN 02 TYPICAL
SCALE:
RECTANGULAR / SQUARE IMRF COLUMN ELEVATION
N.T.S
MATCH PERIMETER TIE SIZES AND SPACING.
SCALE: N.T.S
3. "S2" SPACING IS LISTED IN COLUMN SCHEDULE. "S1" Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
EQUALS ONE HALF OF "S2". 26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0009 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


COLUMN COLUMN COLUMN

DOWELS SIZE & NUMBER


11 TO MATCH LARGER OF
UPPER AND LOWER COLUMN
ADD DOWELS IF AREA
OF REINF. IN COLUMN SEE (1) WHEN OFFSET LESS
ABOVE IS LARGER THAN 75mm MAX. SEE 3B WHEN THAN 75mm
COLUMN BELOW. OFFSET LARGER THAN 75mm 0mm

ADD DOWELS IF AREA OF


REINF.

SEE COL.
KICKER S (TYP.)

SEE COL.
SEE COL.

S (TYP.)
KICKER S (TYP.)

SCHD.

SCHD.
SCHD.
IN COLUMN ABOVE IS LARGER

LAP

LAP
LAP

75
FLOOR SLAB THAN COLUMN BELOW. N
10 KEY PLAN

75

50
75

50

50
50

6 MAX. BEND BARS INTO

S MAX.
SLAB/BEAM

SEE COL.
SEE COL.

SEE COL.
SCHD.
SCHD.
1

SCHD.
LAP
LAP
150mm

LAP
MAX.

S (TYP.)

S (TYP.)
9

ADDITIONAL 2 TIES AT BOTTOM OF BEND


BEND General Notes:
MAX. SPACING 150
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


COLUMN NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
COLUMN COLUMN
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

01 COLUMN
SCALE:
IS OFFSET BY LESS THAN 75
N.T.S 02 COLUMN ABOVE IS SMALLER THAN COLUMN BELOW
03 COLUMN SIZE ABOVE IS LARGER THAN COLUMN BELOW 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
SCALE: N.T.S SCALE: N.T.S AND RELEVANT SECTIONS OF THE SPECIFICATION.

TYPICAL DETAIL OF VERTICAL COLUMN


7
REINFORCEMENT

6
LAP

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


COLUMN CONSTRUCTION JOINT AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:
SLAB

TYPICAL SPANNING "S1"

5 Ta Ta
MEYDAN L.L.C
PROVIDE TIES AT

P.O. Box 9305, Dubai , UAE.


T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

TYPICAL SPANNING "S1"

TYPICAL SPANNING "S1"


Principal Consultant:

PLACE THIS PART OF CONC.

75mm KICKER

75mm KICKER
STARTER BARS

PROVIDE TIES AT

PROVIDE TIES AT
D

LAP

LAP
COLUMN MONOLITHICALLY (PROVIDE FULL
WITH
2

TENSION ANCHORAGE)
1/

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


BEAM & SLAB. CONCRETE www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
STRENGTH TO BE GREATEST PO Box 54115 Dubai, UAE
4 OF DOWELS SAME AS P: +971 4 3997758 F: +971 4 3997759

BEAM, SLAB OR COLUMN


CJ COLUMN REINF. Sub-Consultant:
2

2
1/

1/
(PROVIDE FULL
COLUMN CONSTRUCTION JOINT TENSION ANCHORAGE)

Project Name:

3
DUBAI WATER CANAL
COLUMN
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


TYPICAL DETAIL OF COLUMN AT INTERNAL COLUMN TERMINATION DETAIL 05
04 UPSET BEAM OR STEP IN FRAMED SLAB 05 WHERE COLUMN STOPS AT FLOOR LEVEL
06 COLUMN SUPPORTED ON WALL 06 PLANTED COLUMN SUPPORTED ON SLAB
SCALE: N.T.S SCALE: N.T.S
Scale Drawn Checked Approved Size
SCALE: N.T.S SCALE: N.T.S AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0010 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


X X H
11 SEE NOTE 1
X X X X

SEE NOTE 1 SEE NOTE 1

B
N
10 KEY PLAN

8 BARS 10 BARS
4 BARS 6 BARS 03 04 SCALE: N.T.S

01 02 CONDUITS PLACEMENT IN COLUMNS


SCALE: N.T.S

11
SCALE: N.T.S SCALE: N.T.S
SCALE: N.T.S

9
CONDUITS PLACEMENT TO CONFORM TO THE REQUIREMENTS OF
X X X X X UBC1997 AND: THE TOTAL AREA OF EMBEDDED CONDUITS SHALL NOT
X X
SEE NOTE 1 EXCEED 1% OF THE CROSS AREA (B x H) CONDUITS TO BE SECURED General Notes:
1. DO NOT SCALE FROM THIS DRAWING.
TO COLUMN TIES
. 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

SEE NOTE 1 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

X
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

X
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

14 OR 16 BARS
12 BARS 06 SCALE: 24 BARS
07
N.T.S

05 SCALE: N.T.S SCALE: N.T.S

250 MAX.

6
P
LA

SEE NOTE 1
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

5
X

MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
X

T: +9714 3270000 F: +9714 3270007


E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

ROUND COLUMN NARROW COLUMNS L SHAPED COLUMN


08 SCALE: N.T.S 09 SCALE: N.T.S 10 SCALE: N.T.S

NOTES:
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
1. TYPICAL DETAILS TO BE READ IN CONJUNCTION WITH Sub-Consultant:

COLUMN SCHEDULE.
2. FOR LAP LENGTHS AND REFER GENERAL NOTES #
00-S015.
Project Name:
3. TIE VERTICAL BARS WITH LINKS SHOWN DASHED WHEN DUBAI WATER CANAL
3 DIST. 'X' IS GREATER THAN 150mm. SAFA A
DUBAI-UAE
4. CLEAR DISTANCE BETWEEN VERTICAL BARS SHALL BE
NOT LESS: Project Description:

MIXED USE DEVELOPMENT


a) 1.40 TIMES VERTICAL BAR DIAMETER. (RETAIL & RESIDENTIAL)
b) 1.40 TIMES THE MAX. SIZE OF THE COARSE PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
AGGREGATE.
c) 40mm Drawing Title:

STRUCTURAL GENERAL DETAILS -


5. REFER COLUMN SCHEDULE FOR REINFORCEMENT 06
ARRANGEMENTS NOT SHOWN HERE.
6. PROVIDE FULL TIE FOR EVERY OTHER VERTICAL BAR. Scale Drawn
AA
Checked
MA
Approved
NS
Size

1
TYPICAL SECTIONAL N.T.S
26.05.2016 24.08.2017 24.08.2017
A1
7. ALTERNATIVE BAR ARRANGEMENT, MAY BE USED IF
REINFORCEMENT LAYOUT IN COLUMNS APPROVED BY THE CONSULTANT.
Drawing Number

14011603-01-01-00-SG0011
Rev.

0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


2N16
11
FOR SLAB DETAILS FOR SLAB DETAILS
REFER TO LAYOUTS REFER TO LAYOUTS FOR SLAB DETAILS FOR SLAB DETAILS
REFER TO LAYOUTS REFER TO LAYOUTS

LAP

LAP
N
10 KEY PLAN
LAP

LAP
9

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

01 TYPICAL DETAILS AT TOP OF WALLS


02 TYPICAL WALL/SLAB JUNCTION DETAILS 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 SCALE: N.T.S SCALE: N.T.S AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

'U' BARS
AS PER SCHEDULE
7 LAP
PLACE VERTICAL
BARS IN CORNER LAP

TYPICAL

6
LAP

LAP

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


'U' BARS AUTHORITY APPROVAL 0 17.08.2017 NS

'U' BARS AS PER SCHEDULE Purpose of Issue Rev. Date Appoved

T12-300
Client:

AS PER SCHEDULE
'U' BARS
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
'U' BARS Sub-Consultant:

LAP AS PER SCHEDULE


'U' BARS 'U' BARS
AS PER SCHEDULE AS PER SCHEDULE VL. RFT (E.F.)
Project Name:
AS PER SCHEDULE & DETAILS
LAP

LAP

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

HL. RFT (E.F.) Project Description:


AS PER SCHEDULE & DETAILS MIXED USE DEVELOPMENT
LAP

(RETAIL & RESIDENTIAL)


PLOT 01 / 3435338
2 'U' BARS BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
AS PER SCHEDULE LINK / STIRRUPS
TIES AS PER AS PER SCHEDULE
Drawing Title:

SCHEDULE STRUCTURAL GENERAL DETAILS -


07

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017

03 TYPICAL WALL PLAN JUNCTION DETAILS 04 TYPICAL WALL SECTION Drawing Number Rev.

SCALE: N.T.S SCALE: N.T.S 14011603-01-01-00-SG0012 0


All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

SHEAR WALL SHEAR WALL DUBAI MUNICIPALITY STAMP:


SEE PLANS
OUTSIDE CORE INSIDE CORE
11

SEE SHEAR WALL DETAILS


FOR WALL REINFORCEMENT
SHEAR WALL
OUTSIDE CORE BEYOND INSIDE CORE 30 CLEAR COVER
SEE SCHEDULE FOR INTENTIONALLY TO WALLS
WALL RFT. ROUGHENED SURFACE
N
10 INTENTIONALLY COG BAR IF SLAB KEY PLAN
DOWEL BARS TO ROUGHENED SURFACE NOT CONTINUOUS
36

50
MATCH SLAB REINF'T. 36 TYP
TYP. . 36 FOR SLAB REINFORCEMENT
TYP DOWEL BARS TO SEE PLAN
SLAB RFT SLAB REINF.'T . MATCH SLAB REINF'T.
50

TYP.
1.3Ld+400(MIN.) SEE DETAIL SEE PLANS

50
SLAB RFT 1.3Ld+400(MIN.) SLAB REINF.'T
SEE PLANS SEE PLANS
9 T12

1.3Ld (MIN.)
General Notes:
1.3Ld (MIN.) 45MM
CONTINUOUS 1. DO NOT SCALE FROM THIS DRAWING.
DOWEL BARS TO SEAT

50
ALL SLAB REINF'T. TO MATCH SLAB REINF'T. ALL SLAB REINF'T. TO HOOK AT 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
HOOK AT FAR SIDE OF FAR SIDE OF BEAM BY THE ENGINEER.
TYP.

WALL
50

75 (TYP.) 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 CLEAR COVER AT SITE.
SEE SCHEDULE FOR
50 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
BEAM REINFORCING ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
CORK FILLING STRIP AND RELEVANT SECTIONS OF THE SPECIFICATION.

75 OR APP'D EQUIV.
(TYP.)

01 TYPICAL
SCALE:
SLAB/COREWALL CONNECTION
N.T.S 03 TYPICAL
SCALE:
LINTEL BEAM/SLAB CONNECTION
N.T.S
05 TYPICAL
SCALE:
SLAB SEAT AT SHEARWALL
N.T.S

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


SHEAR WALL SHEAR WALL AUTHORITY APPROVAL 0 17.08.2017 NS
SEE PLANS Purpose of Issue Rev. Date Appoved
OUTSIDE CORE INSIDE CORE
Client:

5 SEE SHEAR WALL DETAILS


MEYDAN L.L.C
SHEAR WALL FOR WALL REINFORCEMENT P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
OUTSIDE CORE BEYOND INSIDE CORE
Principal Consultant:
SEE SCHEDULE FOR INTENTIONALLY SURFACE INTENTIONALLY
WALL REINF'T. ROUGHENED SURFACE ROUGHENED
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
INTENTIONALLY FOR SLAB REINFORCEMENT
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
DOWEL BARS TO ROUGHENED SURFACE PO Box 54115 Dubai, UAE
4 MATCH SLAB REINF'T. SEE PLAN P: +971 4 3997758 F: +971 4 3997759
36 Sub-Consultant:
TYP. 36 36
SLAB RFT 1.3Ld+400(MIN.) 50 SLAB RFT TYP TYP
. . DOWEL BARS TO
TYP.

SEE PLANS SEE DETAIL


50

MATCH SLAB REINF'T.

SEE LINTEL BEAM SCHEDULE Project Name:


1.3Ld (MIN.) FOR REINFORCEMENT DUBAI WATER CANAL
3 SLAB REINF.'T
1.3Ld+400(MIN.) SEE PLANS SAFA A
1.3Ld (MIN.)
DUBAI-UAE
ALL SLAB REINF'T. TO ALL SLAB REINF'T. TO HOOK
TYP.
50

HOOK AT FAR SIDE OF SLAB REINF.'T AT FAR SIDE OF BEAM Project Description:
50 75 (TYP.) WALL SEE PLANS MIXED USE DEVELOPMENT
CLEAR COVER SEE SCHEDULE FOR (RETAIL & RESIDENTIAL)
BEAM REINFORCING PLOT 01 / 3435338
75
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
(TYP.)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


08

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1

02 TYPICAL SLAB/COREWALL CONNECTION 04 TYPICAL


SCALE:
LINTEL BEAM/SLAB CONNECTION
N.T.S
06 LINTEL
SCALE:
BEAM DETAIL
N.T.S
26.05.2016 24.08.2017 24.08.2017
SCALE: N.T.S Drawing Number Rev.

14011603-01-01-00-SG0013 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

MIN. CLEARANCE WHERE NO LINK BEAM DUBAI MUNICIPALITY STAMP:


BETWEEN SLEEVES OCCURS ABOVE RECTANGULAR
11 OPENING ADD BARS TO
IS THE LARGER
DIAMETER 'D' MATCH CUT VERT. REINF.
NUMBER ADDED BARS AT EACH
D D
U BAR TO MATCH VERT. FACE TO EQUAL HALF U BAR TO MATCH
600 600 HORIZONTAL OR VERTICAL NUMBER OF CUT BARS PLUS 1 HORIZONTAL OR VERTICAL
TRIM BARS TO
MAX. MAX. REINFORCEMENT. REINFORCEMENT.
MATCH WALL N
10
HORIZONTAL BARS
KEY PLAN
CL (1)-T16 E.F. MIN.

FOR D>=450
ADD (1)-T16
x1.8m E.F.
9
FOR WALLS
300 & THICKER NOTES:
General Notes:
TRIM BARS.
CLASS 'B' SPLICE 1. LENGTH OF TRIM 1. DO NOT SCALE FROM THIS DRAWING.
TRIM BARS TO 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
BARS = D+1200 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
MATCH WALL BY THE ENGINEER.
'W'
VERTICAL BARS 2. OMIT TRIM BARS 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 EQ. EQ. SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
AT SITE.
(1)-T16 E.F. MIN. FOR SINGLE
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
OPENINGS AND RELEVANT SECTIONS OF THE SPECIFICATION.

A SECTION (A) WHEN D<150


01 CIRCULAR
SCALE:
OPENING
N.T.S
SCALE: N.T.S

7
TENSION
ADD (2)-T16 SPLICE SPLICE SHEAR WALL

B
----
A
----

LENGTH LENGTH
x1800 E.F. WIDTH
TYP. FOR WALLS
300 & THICKER T12 STIRRUPS AT 100mm
ONE PIECE OR 2 PIECE
6 A CLOSED STIRRUP UNO 4T20 U.N.O
---- (2)-T16 FOR 900mm
OPEN WIDE OR SMALLER T.O.S 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
OPENINGS AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
(2)-T20 FOR WIDER
TYP.
600

Client:
OPENINGS EXCEPT
H

AS NOTED.
5
'W'=2100mm MAX. MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
30

H
T: +9714 3270000 F: +9714 3270007
'W' 600 T12 STIRRUPS E: info@dubairacingclub.com W: www.dubairacingclub.com
SHEAR WALL RFT. CL Principal Consultant:
TYP. SEE DETAILS, TYP.

4T20 U.N.O T12 AT 100 E.F. U.N.O abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com

02 RECTANGULAR OR SQUARE OPENING Hassanicor Building, 6th Floor, Al Barsha 1


PO Box 54115 Dubai, UAE
SCALE: N.T.S P: +971 4 3997758 F: +971 4 3997759
4
CONT SHEAR WALL Sub-Consultant:
TOP OF OPENING RFT. SEE DETAILS
(2)-T16 FOR 900mm T12 AT 100mm E.F. U.N.O 4T20 U.N.O
A
----

WIDE OR SMALLER
OPENINGS BEND WHERE VERTICAL
SHEAR WALL RFT. BARS BEYOND
(2)-T20 FOR WIDER ADJACENT Project Name:
SEE DETAILS, TYP.
3 OPENINGS EXCEPT OPENING HOOK HORIZONTAL
DUBAI WATER CANAL
Ld

Ld SAFA A
AS NOTED. INTERFERES T10 TIES AT 150mm BARS AT OPENING
FULL HEIGHT OF DUBAI-UAE
'W'=2100mm MAX. OPENING
(2)-T16 FOR 900mm B SECTION (B) Project Description:
DOWELS INTO
WIDE OR SMALLER
SCALE: N.T.S MIXED USE DEVELOPMENT
A SLAB OR FOOTING (RETAIL & RESIDENTIAL)
---- OPENINGS PLOT 01 / 3435338
2 OPEN (2)-T20 FOR WIDER BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
LENGTH
SPLICE

NOTE
L1

CLASS 'B' OPENINGS EXCEPT Drawing Title:

PLACE BARS IN AS NOTED.


SPLICE STRUCTURAL GENERAL DETAILS -
SAME PLANE 'W'=2100mm MAX.
09
L2

FOR WALLS L2=Ld


ADD. RFT. AS TYP. CONC.
200 OR LESS. SLAB OPENING DETAIL, Scale Drawn
AA
Checked Approved
NS
Size
MA
1 'W' N.T.S
26.05.2016 24.08.2017 24.08.2017
A1
BEND IF
04 TYPICAL SHEAR WALL BEAM DETAIL Drawing Number Rev.

03 DOOR
SCALE:
OPENING
N.T.S
NECESSARY SCALE: N.T.S
14011603-01-01-00-SG0014 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

CL OF BEAM CL OF BEAM CL OF BEAM CL OF BEAM


DUBAI MUNICIPALITY STAMP:
TEMPERATURE REINF. TEMPERATURE REINF. TEMPERATURE REINF.
WHERE REQUIRED WHERE REQUIRED WHERE REQUIRED
11 (SEE NOTE #3) (SEE NOTE #3) (SEE NOTE #3)

SLAB THICKNESS

SLAB THICKNESS

SLAB THICKNESS
1/4 L1 1/3 L 1/3 L 1/3 L 1/3 L GREATER OF (1/4 L3, 1.5 L4)

PER SCHEDULE

PER SCHEDULE

PER SCHEDULE
TOP LEFT REINF. TOP RIGHT REINF. TOP RIGHT REINF. TOP RIGHT REINF.
OF SPAN #1 OF SPAN #1 OR 'Ld' SPLICE TYPICAL OF SPAN #2 OR OF SPAN #3 OR
TOP LEFT REINF. TOP LEFT REINF. TOP LEFT REINF.
OF SPAN #2 OF SPAN #3 OF SPAN #4

STD. HOOK STD. HOOK N


10 KEY PLAN

BOTTOM REINF. BOTTOM REINF. BOTTOM REINF.


PER SLAB SCHEDULE PER SCHEDULE PER SCHEDULE
DISTRIBUTION REINF. Ldc DISTRIBUTION REINF. Ldc DISTRIBUTION REINF. Ldc DISTRIBUTION REINF.
PER SLAB SCHEDULE PER SLAB SCHEDULE PER SLAB SCHEDULE PER SCHEDULE
(SEE NOTE #1) (SEE NOTE #1) (SEE NOTE #1) (SEE NOTE #1)

9
BEAM CLEAR SPAN - L1 BEAM CLEAR SPAN - L2 BEAM CLEAR SPAN - L3 BEAM CLEAR SPAN - L4

EXTERIOR SPAN #1 EXTERIOR SPAN #2 EXTERIOR SPAN #3 CANT. SPAN #4


(WHERE OCCURS) General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
NOTES: AND RELEVANT SECTIONS OF THE SPECIFICATION.

1. ALL BOTTOM REINFORCEMENT SHALL BE CONTINUOUS WITH CLASS 'A' SPLICE AT SUPPORTS.
01 TYPICAL
SCALE:
SECTION AT ONE WAY GRAVITY SLAB
N.T.S
TOP DISTRIBUTION REBARS ARE ANCHORED IN END SUPPORTS WITH STD. HOOK.
2. SEE CONCRETE NOTES FOR CONCRETE COVERS.
3. PROVIDE TEMPERATURE REINF. TO MATCH SLAB DISTRIBUTION REINF. WHERE TOP OF SLAB IS EXPOSED TO WEATHER.
7
4. L IS GREATER OF ADJACENT SPAN.

CUT BARS
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

. AUTHORITY APPROVAL 0 17.08.2017 NS


P PLACE TRIM BARS SAME SIZE AS
.
EQ

Rev.
TY
Purpose of Issue Date Appoved
CUT BARS AT EACH FACE OF OPENING. TRIMMER BARS Client:

P. NUMBER OF TRIM BARS AT EACH FACE


.
EQ

5 TY TO EQUAL HALF OF CUT BARS PLUS 1.


MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
LAP LAP

1 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
----
OPEN Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
4 U-BARS OF THE SAME Sub-Consultant:
P: +971 4 3997758 F: +971 4 3997759

DIAMETER
AS THE BARS ON TO WHICH
600
THEY LAP TYPICAL.
TYP.

TYP. ADDITIONAL DIAGONAL REINFORCEMENT


600

T16 x 1200 TOP AND BOTTOM Project Name:

AT EACH CORNER OF ALL OPENINGS DUBAI WATER CANAL


3 A SECTION
SCALE:
(A)
N.T.S SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
02 TYPICAL SLAB OPENING OVER THAN 150mm PLOT 01 / 3435338
2 SCALE: N.T.S BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
TRIMMING REFT FOR HOLES IN SLABS Drawing Title:

NOTES : 1. ALL REPLACEMENT AND DIAGONAL BARS SHOULD STRUCTURAL GENERAL DETAILS -
EXTEND AN ANCHORAGE LENGTH BEYOND THE 10
1. REINF. SIMILAR FOR CIRCULAR OPENINGS. EDGE OF THE HOLE.
2. FOR OPENINGS LARGER THAN 600mm (ANY SIDE) SEE PLAN FOR TRIM REINF.
2. HOLES LARGER THAN 900 mm IN ANY DIRECTION ARE
Scale Drawn Checked Approved Size
AA MA NS
1 3. OPENINGS LARGER THAN 600mm (ANY SIDE) NOT SHOWN ON STRUCTURAL PLANS N.T.S A1

MUST BE APPROVED BY STRUCTURAL ENGINEER PRIOR TO CONSTRUCTION. DETAILED ON THE DRAWINGS 26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0015 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

MULTIPLE LAYERS OF RFT ARE NUMBERED IN ASCENDING ORDER FROM THE


OUTERMOST LAYER INWARDS AS SHOWN BELOW: Ld
DUBAI MUNICIPALITY STAMP:
T1 T2
11
T 4T20
T&B

T
B1 B2
N
10 KEY PLAN
S = LESS THAN 0.8T 1.5T
01 NOTATION
SCALE:
FOR PLACEMENT OF SLAB REINFORCEMENT
N.T.S
Ld
NOTES:
T1 DENOTES FIRST (OUTERMOST) LAYER OF TOP REFT.
T2 DENOTES SECOND LAYER TOP REFT.
B1 DENOTES FIRST (OUTERMOST) LAYER OF BOTTOM REFT. 05 TYPICAL
SCALE:
SLAB STEP DOWN DETAILS
N.T.S
B2 DENOTES SECOND LAYER OF BOTTOM REFT.
9

ADD 1-T10-400 TOP x 1000


CONSTRUCTION JOINT AT LONG WHEN NO TOP General Notes:
MIDSPAN ONLY REINFORCEMENT IS NOTED Ld
KEY CUT NOTE:
ON PLAN 4T20 1. DO NOT SCALE FROM THIS DRAWING.

CUT KEYS IN SLABS AS FOLLOWS: T&B 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


CL SLAB THICKNESS KEY SIZE SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
LESS THAN 150 38 x 38
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
150 TO 250

S
38 x 39 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
250 TO 350 38 x 140
REFER KEY CUT NOTE 350 & THICKER 38 x 184

T
02 SLAB
SCALE:
CONTROL JOINT
N.T.S
NOTES: SAME SIZE & SPACING
7 AS PER SLAB REINF'T.
1. JOINT LOCATION TO BE APPROVED BY ENGINEER U.N.O. 1.5T
2.EXTEND SLAB REINFORCEMENT THROUGH JOINT FOR THE FULL LENGTH
STIPULATED ON PLAN AND OR TYPICAL DETAILS. Ld
S = GREATER THAN 0.8T
CL LESS THAN 1.5T

6 DOWEL BARS TO
DOWEL BARS TO MATCH SLAB REINF'T.
MATCH SLAB REINF'T.

SLAB TOP BAR


06 TYPICAL
SCALE:
SLAB STEP DOWN DETAILS
N.T.S 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 17.08.2017 NS
PER SLAB REINF. PLAN
Purpose of Issue Rev. Date Appoved
Client:
FLOOR SLAB LTB LTB CORE WALL SLAB
PER PLAN WHERE OCCURS
5
TENSION LAP MEYDAN L.L.C

75 MAX,.
TENSION LAP
TYP.

P.O. Box 9305, Dubai , UAE.


0

T: +9714 3270000 F: +9714 3270007


E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
TYP.
0

t
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
SLAB BOTTOM BAR CORE WALL SLAB
www.ae-7.com
TENSION LAP Hassanicor Building, 6th Floor, Al Barsha 1
PER SLAB REINF. PLAN REINF. PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
3t 1.5t Sub-Consultant:

DOWEL BARS TO
MATCH SLAB REINF'T. DOWEL BARS TO MATCH SLAB REINF'T.

03 TYPICAL SLAB- WALL CONNECTION DETAIL 07 TYPICAL SLAB STEP - 75mm MAX. Project Name:

3
SCALE: N.T.S
NOTE: SEE PLANS FOR FURTHER INFORMATION.
SCALE: N.T.S DUBAI WATER CANAL
SAFA A
DUBAI-UAE
WALL
Project Description:
ADDITIONAL 0.25 L 0.5 L 0.25 L
DIAGONAL BARS AT SLAB
MIXED USE DEVELOPMENT
TOP & BOTTOM (RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:
L
STRUCTURAL GENERAL DETAILS -
EDGE BEAM
COLUMN NOTE: 11
ADDITIONAL 1. WHERE REINF'T. IS TO BE DETAILED CONTINUOUSLY LAPS IN
SLAB DIAGONAL BARS Scale Drawn Checked Approved Size
AT TOP & BOTTOM REINF'T. MAY OCCUR ONLY IN SHADED AREAS SHOWN N.T.S
AA MA NS
1 A1
26.05.2016 24.08.2017 24.08.2017

04 CORNER REFT DETAILS 08 LAP LOCATIONS Drawing Number Rev.

SCALE: N.T.S
SCALE: N.T.S 14011603-01-01-00-SG0016 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11 BEAM, SLAB OR STAIR MIX.


200 MAX.

ELECT. DWGS.
CHANNEL GRATING FOR DETAIL ROUGHEN JOINT

SEE MECH./
100 100 125 MIN.

'Ld'
REFER MECHANICAL DWGS. 25 CLR. T12 @ 200 O.C.
MIN. MIN. EACH WAY 25 CLR.

ELECT. DWGS.
SLAB TYP. SLAB

SEE MECH./
a E.F. REBAR REBAR TYP.
SUPPORT TO
HANGER WALL WALL/COLUMN SLAB
(2)T12 CONT. @300 O.C.

MAX.
b E.F. MIX

150
45° 45° EL. SEE PLAN

SLAB

MAX.
450
EL. SEE PLAN
FL. LEV.
N
10 T12 @ 300 O.C. KEY PLAN

Ld (OR LDh WITH

Ld (OR LDh WITH


STD. 90 HOOK)
ALT.

STD. 90 HOOK)
T10-200-EW, EF

01 TYPICAL
SCALE:
DETAILS OF HANGER WALL
N.T.S

TYPICAL JUNCTION DETAILS FOR COLUMNS &

TYP.

TYP.
NOTE:
02 DETAIL
SCALE:
OF DRAIN CHANNEL IN SLABS
N.T.S 03 BEAMS
SCALE:
WITH DIFFERENT GRADE OF CONCRETE
N.T.S
FOR (a) & (b) VALUES REF WALL SCHEDULE IF APPLICABLE
MACHINE BASE POURED MONOLITHIC WITH SLAB CURB WIDTH 200 MAX. 125 MIN.
20DIA. HOLES ON
ANGLE
70
ADDITIONAL BARS GALVANIZED 75x75x6 EA AT 200 CENTRES.
SLAB REINF'T 2T16 TOP & BOTTOM 6DS MIN. D2 LESS THAN 1\3 T
'L' 200 MIN.
T16

T16

70
ROUGHEN JOINT
9 'L' 'L'
W 25 CLR.

ELECT. DWGS.
t

ELECT. DWGS.
T12 @ 200 O.C.

1/3
SLAB

SEE MECH./
TYP.

SEE MECH./
EACH WAY REBAR
25 CLR.

1/3

T
SLAB CLASS 'A' SPLICE ROUGHEN JOINT
1 T12 AT 150 CENTRES

1/3
TYP. (2)T12 CONT. @300 O.C.
t

1 REBAR TYP. General Notes:


T16

D2 LESS THAN 1\3 T


T16

200 200 D1 LESS THAN 1\3 T T12 HOOKED BAR SLAB SLAB

MAX.
MAX.
WELDED TO ANGLE AT

450
EL. SEE PLAN

150
EL. SEE PLAN 1. DO NOT SCALE FROM THIS DRAWING.
500 CENTRES MAX.
SLAB REINF'T NOTE: T12 (L)-BAR AT 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
1. CONDUITS SHALL BE PLACED IN MIDDLE THIRD OF WALL THICKNESS. 150 CENTRES NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
2. DS IS THE LARGER OF D1 OR D2. VALVE PIT COVERS AND TRENCH COVERS T12 @ 300 O.C. BY THE ENGINEER.

Ld (OR LDh WITH


EACH WAY

STD. 90 HOOK)
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 TYPICAL RECESS DETAIL FOR SUMP PIT COVERS, SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

Ld (OR LDh WITH


STD. 90 HOOK)
AT SITE.
06 VALVE PIT COVERS AND TRENCH COVERS

TYP.
04 TYPICAL
SCALE:
SECTION FOR U-CHANNEL OF SLAB
N.T.S 05 CONDUIT
SCALE:
PLACEMENT IN WALLS
N.T.S
SCALE: N.T.S
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

TYP.
CURB WIDTH 200 MIN. AND RELEVANT SECTIONS OF THE SPECIFICATION.

A393 BRC FABRIC MESH MACHINE BASE POURED AFTER SLAB POUR NOTES:
TOC NOTES:

50
2 x 2-T20 FOR WALLS THICKER THAN 450 1. SEE MECHANICAL, ELECTRICAL, PLUMBING AND ARCHITECTURAL
PER 50 150 1. SEE MECHANICAL, ELECTRICAL, PLUMBING AND ARCHITECTURAL DRAWINGS FOR LOCATION AND DRAWINGS FOR LOCATION AND DIMENSIONS OF MACHINE BASE.
DIMENSIONS OF MACHINE BASE. THE CONTRACTOR SHALL COORDINATE THE PROVISION OF MACHINE THE CONTRACTOR SHALL COORDINATE THE PROVISION OF CURBS
4 SETS OF ADDITIONAL LINKS BASE DOWELS FROM THE SLAB PRIOR TO THE CONCRETING OF THE SLAB. DOWELS FROM THE SLAB PRIOR TO THE CONCRETING OF THE SLAB.
SLEEVES 200 DIA. MAX.
SPEC

HARDCORE
200 MIN.

AS

2. CLEAR COVERS TO BARS SHOWN ARE FOR INTERIOR CONDITIONS. FOR OTHER CONDITIONS
S

2. CLEAR COVERS TO BARS SHOWN ARE FOR INTERIOR CONDITIONS. FOR OTHER CONDITIONS
7 SEE CONCRETE NOTES.
900 MIN. 400 900 MIN SUB-GRADE
MIN
WATERPROOFING IF REQUIRED
REFER TO STRUCTURAL DRAWINGS FOR REINFORCEMENT
AT SLEEVES GREATER THAN 200 DIA. 50mm BLINDING
1000 GAUGE POLYTHENE SHEET

07 REINFORCEMENT
SCALE: N.T.S
AT SLEEVES THROUGH WALLS 08 TYPICAL
SCALE:
DETAILS OF GRADE SLAB (150mm)THICKNESS
N.T.S 15 TYPICAL
SCALE:
MACHINE BASE REINFORCING AT SLAB
N.T.S 16 TYPICAL
SCALE:
CONCRETE CURB REINFORCING AT SLAB
N.T.S

ISOLATION JOINT 20mm


A393 FABRIC MESH THICK COMPRESSIBLE EDGE OF OTHER
6 FILLER BOARD WITH
SEALANT TO
STRUCTURE FABRIC MESH
TOC
50

ARCHITECT'S DETAILS
TOC

50
PER 50 200

PER 50 H
2H 2H
0
2H

100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS


SPEC

HARDCORE AUTHORITY APPROVAL 0 17.08.2017 NS

SPEC
AS

HARDCORE

AS

S
1
2 Purpose of Issue Rev. Date Appoved
SUB-GRADE SUB-GRADE Client:
WATERPROOFING IF REQUIRED
WATERPROOFING IF REQUIRED
50mm BLINDING
50mm BLINDING
1000 GAUGE POLYTHENE SHEET
5 1000 GAUGE POLYTHENE SHEET
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
09 TYPICAL
SCALE:
DETAILS OF GRADE SLAB (200mm) THICKNESS
N.T.S 10 TYPICAL
SCALE:
EDGE DETAILS OF ON GRADE SLAB
N.T.S
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

SAW CUT OR FORMED GROVE, SAW CUT OR FORMED GROVE,


5mm 5mm
WIDE, SEALED TO ARCHITECT'S INDUCED CRACK WIDE, SEALED TO ARCHITECT'S BUTT JOINT
DETAILS DETAILS (UNTREATED) abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
A393 FABRIC MESH 50 50 50 50 www.ae-7.com
FABRIC MESH FABRIC MESH Hassanicor Building, 6th Floor, Al Barsha 1
TOC TOC
50

50

PO Box 54115 Dubai, UAE


P: +971 4 3997758 F: +971 4 3997759
4
PER 50 H

PER 50 H

H/2

Sub-Consultant:
50

EQUAL EQUAL EQUAL EQUAL


SPEC

SPEC

HARDCORE HARDCORE
AS

AS
S

SUB-GRADE SUB-GRADE

WATERPROOFING IF REQUIRED MILD STEEL DOWEL BARS, 20mm DIA. WATERPROOFING IF REQUIRED
x
50mm BLINDING 500LG @ 300 CTS DE-BONDED OVER 50mm BLINDING
TWO THIRDS LEHGTH. (SET
1000 GAUGE POLYTHENE SHEET PERPENDICULAR TO JOINT) 1000 GAUGE POLYTHENE SHEET Project Name:

3 11 INDUCED
SCALE:
TIED JOINT (IT)
N.T.S 12 FORMED
SCALE:
DOWELLED CONTRACTION JOINT (FDC)
N.T.S
DUBAI WATER CANAL
SAFA A
SAW CUT OR FORMED GROVE, 5mm
WIDE, SEALED TO ARCHITECT'S JOINT COMPRISES COMPRESSIBLE FILLER BOARD, DUBAI-UAE
DETAILS BUTT JOINT 20mm THICK, WITH SEALANT TO ARCHITECT'S DOWEL CAP, END FILLED WITH
(UNTREATED) DETAILS COMPRESSIBLE MATERIAL
50 50 50 20 50
Project Description:
FABRIC MESH FABRIC MESH
TOC 100 20
TOC
MIXED USE DEVELOPMENT
50

50

(RETAIL & RESIDENTIAL)


PER 50 H

PER 50 H
H/2

H/2

EQUAL EQUAL PLOT 01 / 3435338


SPEC

SPEC

HARDCORE HARDCORE
AS

AS
S

2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)


SUB-GRADE SUB-GRADE
Drawing Title:
MILD STEEL DOWEL BARS, 12mm DIA.
WATERPROOFING IF REQUIRED WATERPROOFING IF REQUIRED
MILD STEEL DOWEL BARS, 20mm DIA. x
x
900 LG. @ 600 CTS. (SET
PERPENDICULAR TO JOINT)
50mm BLINDING
1000 GAUGE POLYTHENE SHEET
550 LG. @ 300 CTS. DE-BONDED OVER
TWO THIRDS LENGTH (SET
PERPENDICULAR TO JOINT)
50mm BLINDING
1000 GAUGE POLYTHENE SHEET
STRUCTURAL GENERAL DETAILS -
12
13 LONGITUDINAL
SCALE: N.T.S
JOINT (LJ) 14 EXPANSION
SCALE:
JOINT (EJ)
N.T.S

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0017 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

200 OR 300
T10-300

----
D
LINKS

T10

1500 MAX. (FOR 200 THICK)


2500 MAX. (FOR 300 THICK)
T10 T10
300 1500 300 T10 T16-160 (FOR T10-300 (FOR 200
200 THICK) T16-200
T10 THICK) T16-200 E.F.

200
T10-300 E.F. E.F. (FOR 300
T12-300 T12-300 T12-300 (FOR 300 THICK)
THICK) T10-300 E.F.
C T10-300 E.F. T16-160 (FOR (FOR
T10-300 E.F. ---- 200 200 THICK) T10- N
T10

1250 MAX.
10 THICK) T16-200 250 KEY PLAN

(MIN. 750)
T10-250 E.F.

D+300
T10-250 E.F. E.F. (FOR 300 E.F. (FOR 300
100 100 THICK) THICK)
T12-300
T10-300 SLAB RFT
100

200
150

T10-300

200 MIN.750 200


mm mm TRIMMING BEAMS FOR
MANHOLE.
T8-150 T10-250
9 75 THICK
BLINDING LAYER

01 TYPICAL
SCALE:
DETAILS OF PORTIABLE PLANTER
N.T.S 02 TYPICAL
SCALE:
R.C. DETAIL OF MANHOLE
N.T.S C SECTION
SCALE:
(C)
N.T.S 06 TYPICAL
SCALE:
DETAILS OF PARAPET WALL
N.T.S
General Notes:
1. DO NOT SCALE FROM THIS DRAWING.
150
GALVANIZED T16 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
T10 T10

80
REINF'T FOR T10 REINF'T FOR HORIZ. BARS VERT. BARS
T10 FLOOR BEAM 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
FLOOR BEAM
T10 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 T10-300
LINKS 150x80x65 BOXOUT AT SITE.

300 300 T10-300 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
VARIES PLAN ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
T10-300
T10 AND RELEVANT SECTIONS OF THE SPECIFICATION.
150
T10-250 T10-250
T12-300 T12-300 T12-300 SPLAY BARS TOP LEVEL AT FFL
VERT. BARS

65
T10-300 E.F.
1250 MAX.

HORIZ. BARS

150 MIN.
T12-300 T10-300
GALVANIZED T16
7
ELEVATION
SLAB REINF'T FOR COVERS > 1500mm LONG (MIN. 2 HOOPS PER COVER UNIT)
T8-150 T10-250
75 THICK
BLINDING LAYER

LIFTING HOOP - IN ANY ORIENTATION


D SECTION (D) 05 TYPICAL TANK WALL CORNER DETAILS 07 TO AVOID EXPOSING OTHER REINFORCEMENT
03 TYPICAL DETAILS OF PLANTER WALL SCALE: N.T.S
SCALE: N.T.S SCALE: N.T.S
SCALE: N.T.S

6
N.
8D. MIN.
0 MI ALT. CROSS TIE
10D.MAX. 10

db
IN. END IN ALL

=6
. M AX.
----
A

D
8 .M CROSS CASES

R
0 NS

LE
100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017
10D TIE

AL
DETAILING 0 NS

SM
AUTHORITY APPROVAL 17.08.2017
250

5&
DIMENSION

db
. Purpose of Issue Rev. Date Appoved

T2
MIN D

100 MIN.
150 Client:

T16 & SMALLER = 6db


B
D
H

T19, T22, T25 = 12db


---- db
750
UN

65 MIN.
O

4db
T12-200 E.F. COLUMN REINFORCEMENT
5
550

T10-300 E.F. 2r OR 5mm + DIA. OF COLUMN BAR MEYDAN L.L.C


WHICHEVER IS GREATER P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
250

E: info@dubairacingclub.com W: www.dubairacingclub.com
300

Principal Consultant:
750 750 8.1 LINKS
SCALE: N.T.S 8.2 SPANDREL
SCALE:
& BEAM SUPPLEMENTARY TIE
N.T.S 8.3 STANDARD
SCALE:
180-DEGREE HOOK
N.T.S
250 UN 250
O 250 UN 250
O
T10-300 T12-200 T16 & SMALLER = 6db abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

.
IN
T19, T22, T25 = 12db www.ae-7.com

0M
T25 & SMALLER = 6db Hassanicor Building, 6th Floor, Al Barsha 1

10
PO Box 54115 Dubai, UAE

db
100mm MIN.

=6
P: +971 4 3997758 F: +971 4 3997759
4

R
LE
Sub-Consultant:

DIMENSION
DETAILING
AL
CL BEAM 10
0M

SM
04 TYPICAL R.C. DETAIL OF SUMP PIT IN LIFT PIT B SECTION (B)
D IN

5&
SCALE: N.T.S SCALE: N.T.S
D .

T2
db db
db

Project Name:

DUBAI WATER CANAL


H

3
8.4 BEAM
SCALE:
& JOIST STIRRUP
N.T.S 8.5 COLUMN
SCALE:
& SPANDREL TIE
N.T.S 8.6 135-DEGREE
SCALE:
STIRRUP/TIE HOOK
N.T.S
SAFA A
T12-200 E.F.
DUBAI-UAE
550

T10-300 E.F.

Project Description:
DETAILING NOTES:
300

WIRE TOGETHER DIMENSION MIXED USE DEVELOPMENT

db
EACH END 1. REFERENCE ACI 318M-05.
300 750 300 2. db = BAR DIAMETER. (RETAIL & RESIDENTIAL)
PLOT 01 / 3435338

EXTENSION
3. D = DIAMETER OF BEND

100 MIN.
CLASS "B"

U.N.O.
T12-200 T10-300 D
2 SPLICE U.N.O. 12db D = 6db FOR 8 THRU 25 BARS BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
D = 8db FOR 32 THRU 36 BARS
D = 10db FOR 40 AND LARGER Drawing Title:

8.7 TIE LAP DETAIL


SCALE: N.T.S 8.8 STANDARD
SCALE:
90-DEGREE HOOK
N.T.S
STRUCTURAL GENERAL DETAILS -
13
A SECTION (A)
08 TYPICAL BAR BENDING DETAILS
SCALE: N.T.S
SCALE: N.T.S
Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0018 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

1-T20 BAR x 350 LONG NOTES:


DEBONDED IN POST
SUSPENDED SLAB

S019
1-T20 BAR x 350 LONG DEBONDED IN POST 1.01 ALL MASONRY CONSTRUCTION SHALL CONFORM TO BS 6073, BS 5628 AND

A
CONTROL JOINT
SPECIFICATIONS.

1.02 ALL CONTROL JOINTS ARE TO BE FILLED WITH COMPRESSIBLE EXPANDABLE


FILLER, REFER ALSO TO PROJECT SPECIFICATIONS FOR FIRE RATED WALLS. N
10 KEY PLAN
1.03 ALL WALL FINISHES MUST BE JOINTED AT THE WALL JOINTS TO PREVENT
UNCONTROLLED CRACKS IN THEM.

1.04 GREAT CARE MUST BE TAKEN TO ENSURE THAT MORTAR DROPPINGS AND
OTHER HARD MATERIALS DO NOT FALL OR REMAIN IN THE CONTROL JOINTS.
1 POLYSTYRENE TO BE PLACED IN ALL VERTICAL JOINTS DURING CONSTRUCTION
S019 IN MASONRY TO AVOID MORTAR DROPPINGS FILLING THE JOINTS.

1.05 ALL JOINTS ARE TO BE REVIEWED AND APPROVED BY THE ARCHITECT OR HIS
S019 REPRESENTATIVE PRIOR TO USE.
B
S019
9 1.06 WHERE FILLER MATERIALS ARE NOT SPECIFIED BY A TRADE NAME, THE
D
S019 CONTRACTOR SHALL SUBMIT THE NAME OF HIS PROPOSED FILLERS TO THE
B CONSULTANT FOR REVIEW PRIOR TO USE.

BCJ BCJ FIXED END CONCRETE COLUMN 1.07 THE CONTACTOR'S ATTENTION IS DRAWN TO THE MANUFACTURER'S General Notes:
SUPPORT POST SUPPORT POST REQUIREMENTS WITH REGARD TO THE POSITION OF THE FLEXIBLE ANCHORS
FOR FOR BCJ WHEN FIXED. THE MANUFACTURER'S WRITTEN RECOMMENDATIONS SHALL BE 1. DO NOT SCALE FROM THIS DRAWING.

BLOCKWORK F F BLOCKWORK FOLLOWED STRICTLY. 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
1.08 THE CONTRACTOR IS TO TAKE PARTICULAR CARE TO ENSURE THAT ALL BY THE ENGINEER.
PERPENDS AND BEDS ARE PROPERLY FILLED WITH MORTAR. 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
1.01 REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR LOCATIONS OF AT SITE.

CONTROL JOINTS. 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
4250 MAX. BETWEEN CONTROL JOINTS 4250 MAX. BETWEEN FIXED END AND CONTROL JOINT 1.10 PROVIDE RESTRAINT TO ALL MASONRY AT SOFFIT OF SLAB OVER AS REQUIRED. AND RELEVANT SECTIONS OF THE SPECIFICATION.

NOTES: 1.11 WHERE STARTER BARS, ANCHOR BOLTS, ETC. ARE SHOWN PROJECTING INTO
2 MASONRY, BUILD THESE TIGHTLY INTO MASONRY VOIDS WITH MASONRY GROUT.
BED JOINT REINFORCEMENT EVERY SECOND 1. BCJ. DENOTES BLOCKWORK CONTROL JOINT. REFER ARCH. PLANS FOR LOCATION
COURSE S019 1.12 PROVIDE HORIZONTAL BED JOINT REINFORCEMENT AS PER SPECIFICATIONS AND
2. WALL TIES TO BE PLACED AT 400mm VERTICAL SPACING 1000mm HORIZONTAL SPACING(STAGGERED)
(EXTERNAL SINGLE LEAF WALL ONLY) DETAILS ON DRAWINGS.
3. ALL DETAILS SHOWN ARE FOR NON LOAD BEARING BLOCKWORK (UNO)

01 TYPICAL BLOCKWORK ELEVATI0N


7 1.13 PROVIDE LINTELS OVER ALL OPENINGS OR RECESSES IN MASONRY WALLS,
SCALE: N.T.S INCLUDING THOSE FOR MECHANICAL OR ELECTRICAL SERVICES OR EQUIPMENT.
SEE TYPICAL DETAILS FOR LINTEL SIZES FOR NON-LOAD BEARING MASONRY
WALLS.
B 1.14 THE AVERAGE MATERIAL DENSITY OF MASONRY UNITS TO BE AS FOLLOWS:
HOLLOW MASONRY UNITS : 750 Kg/Cubic M
HOLLOW BLOCKWORK UNITS : 1500 Kg/Cubic M

BED JOINT REINFORCEMENT OVER LINTEL 600 LAP FORM OPENING EDGE 1.15 FIRE RATING REQUIREMENTS, SOUND AND THERMAL INSULATION PROPERTIES TO
HORIZONTAL O BE AS PER PROJECT SPECIFICATIONS.
6 REINFORCEMENT WITH GALAVANISED STEEL MESH OF 4mm DIA
1.16 CUTTING AND CHASING OF MASONRY WALLS TO BE STRICTLY IN ACCORDANCE
LONGITUDINAL WIRES WITH THE SPECIFICATION AND DM REQUIREMENTS.
AND 2.52mm DIA CROSS WIRE. LAP REIN. 150mm AT EVERY SECOND LAYER
CONCRETE LINTEL
C REINF. SYMM.
LINKS A 1.17 MORTAR MIX TO BE 1:1:6 (CEMENT:LIME:SAND) OR APPROVED EQUIVALENT. 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 17.08.2017 NS
CLEAR SPAN 1.18 TIES @400C/C TO ALL STRUCTURE COLUMN/SHEAR WALLS VERTICALLY WITH Purpose of Issue Rev. Date Appoved
MINIMUM 125MM FULL EMBEDMENT EACH SIDE OF THE ANCHOR.
Client:

03 LINTEL
SCALE:
BEAM DETAIL -1
N.T.S
1.19 DEFLECTION JOINTS @ HEADS WITH HORIZONTAL STABILIZATION BY STRUCTURAL
ANGLES ATTACHED TO U/S SIDE OF JOINT
600 600
40 DIA. OF BAR
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
30 mm DEFLECTION JOINT T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
ANGLE AT OPPOSITE
SIDE OF WALL Principal Consultant:
1200
VERTICAL O
SIDES 600
C
OF DOORS S019 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
AND Hassanicor Building, 6th Floor, Al Barsha 1
WINDOWS TO WINDOW OR DOOR
LINKS PO Box 54115 Dubai, UAE
4 BE
CLEAR SPAN
CONCRETE FACE Sub-Consultant:
P: +971 4 3997758 F: +971 4 3997759

GROUTED

S019
A
WITH C E
C15/10 CONC. S019 CONTRACTOR TO ENSURE CORRECT S019 100x100x6x150mm ANGLE
FILL MINIMUM STARTER BARS ARE CAST INTO FIXED TO SLAB FOR
OF CONCRETE ELEMENTS AS NECESSARY MOVEMENT OF
HALF BLOCK BLOCKWALL
SSL NOTES: @ EVERY
20mm CONTROL JOINT FILLED WITH 1200 C/C
Project Name:
1. BEARING ON BLOCK WALL ON EITHER SIDE OF OPENING SHALL BE FIRE RESISTANT COMPRESSIBLE

3 04 LINTEL
SCALE:
BEAM DETAIL - 2
N.T.S
AT LEAST EQUAL TO THE OVERALL DEPTH OF THE LINTEL JOINT
FILLER TO ARCHITECTS
DUBAI WATER CANAL
BED JOINT REINFORCEMENT
2. OVERALL LINTEL DEPTHS COULD BE INCREASED SPECIFICATION. SAFA A
TO SUIT BLOCK WORK COURSING
DUBAI-UAE
LINTEL SIZE REINFORCEMENT
Project Description:
WIDTH DEPTH TOP BOTTOM LINKS
MIXED USE DEVELOPMENT
2.50M 200mm 200mm 2-T12 2-T12 T8@125 (RETAIL & RESIDENTIAL)
TYPICAL BLOCKWORK DETAIL > 2.50M 4.50M 200mm 300mm 2-T16 2-T16 T8@175 PLOT 01 / 3435338

02 WINDOW OR DOOR OPENING


2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
> 4.50M 6.50M 200mm 400mm 2-T16 2-T20 T8@200
SCALE: N.T.S ELEVATION ON NON-LOAD Drawing Title:

17 SCHEDULES OF LINTEL (UNO) 02 BEARING BLOCK WORK WALL


SCALE: N.T.S
SCALE: N.T.S
STRUCTURAL GENERAL DETAILS -
14

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0019 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

T8-100 CTS 4T10

N
10 KEY PLAN

30

30
100x100x6x150mm ANGLE
FIXED TO SLAB FOR MOVEMENT 30mm DEFLECTION JOINT FILLED 30mm DEFLECTION JOINT FILLED
OF BLOCKWALL @ EVERY 1200 FIRE RESISTANT COMPRESSIBLE FIRE RESISTANT COMPRESSIBLE
C/C STAGGERED JOINT FILLER TO ARCHITECTS JOINT FILLER TO ARCHITECTS 200 x 200 POST FOR
(1 NO. ANGLE AT 600 C/C SPECIFICATION. BLOCKWORK SUPPORT POST
SPECIFICATION. 200 THK. BLOCKWORK
9 TOTAL ALTERNATIVE SIDE)

FOR FIRE COMPARTMENTS WALLS AND FOR ORDINARY PARTITIONS General Notes:
ORDINARY WALLS OF HEIGHT MORE THAN 4 METERS 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

B SECTION (B) SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK


8
A SECTION (A) AT SITE.
SCALE: N.T.S
SCALE: N.T.S 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

C15/10 GROUT FILLED


20 mm CONTROL JOINT FILLED
WITH FIRE RESISTANT SLEEVED METAL TIES@ 200 mm
7 CONCRETE COLUMN C/C VERTICALLY
COMPRESSIBLE JOINT FILLER

WALL TIES AT
SLIDING PLASTIC
EVERY OTHER
SLEEVED WALL TIES AT
COURSE FIXED TO
EVERYOTHER COURSE
COLUMN
FIXEDTO COLUMN
T12 VERTICAL REINFORCEMENT
6

FIXED END CONTROL JOINT IN BLOCKWALL WALL


100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
BCJ
Client:

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.

C SECTION (C) D SECTION (D) E SECTION (E) T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S
Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
1-T20 BAR x 350 LONG PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
DEBONDED IN POST REINFORCED Sub-Consultant:
CONCRETE BCJ

125
BLOCK WORK HEAD RESTRAINT
FLOOR SLAB
HORIZONTAL REINFORCEMENT DETAILS SHOWN ON THIS
WITH GALAVANISED STEEL DRAWING ARE APPLICABLE
MESH OF 4mm DIA WHERE FALSE CEILINGS U/S SLAB OR BEAM
LONGITUDINAL WIRES AND PRESENT. 100
2.52mm DIA CROSS WIRE. LAP FIRE RESISTANT COLUMN BARS Project Name:
20

550
REIN. 150mm AT EVERY SECOND
3 LAYER
COMPRESSIBLE JOINT DUBAI WATER CANAL
150 FILLER 1-T12 STARTER SAFA A
LAP BAR CENTRALLY DUBAI-UAE

25mm. DIA PURPOSE


Project Description:
MADE CAP WITH MIXED USE DEVELOPMENT
COMPRESSIBLE FILLER (RETAIL & RESIDENTIAL)

VARIES
PLOT 01 / 3435338
BCJ
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
COLUMN BARS Drawing Title:

STRUCTURAL GENERAL DETAILS -


15
F SECTION (F) 01 DETAIL (1) 02 DETAIL (2)
SCALE: N.T.S SCALE: N.T.S SCALE: N.T.S
Scale Drawn Checked Approved Size
AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0020 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

02 04
LINKS CIP SLAB LINKS CIP SLAB

N
10 KEY PLAN

750
LINKS LINKS

01 01 03 03

EQ

EQ
9

EQ

EQ
EQ

EQ
50 AS PER DESIGN General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

02 04

7
PS1 TYPICAL PUNCHING SHEAR DETAIL (INTERNAL COLUMN)
SCALE: 1:25
PS2 TYPICAL
SCALE:
PUNCHING SHEAR DETAIL (EDGE COLUMN)
1:25

LINKS
SLAB RFT
6

SLAB
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
LINKS
SLAB RFT SLAB RFT 50 AUTHORITY APPROVAL 0 17.08.2017 NS
AS PER PLAN Purpose of Issue Rev. Date Appoved
Client:
SLAB

SLAB

50 50 R.C. COLUMN
5
AS PER PLAN AS PER PLAN MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
R.C. COLUMN

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

03 SEC. (03-03) www.ae-7.com


Hassanicor Building, 6th Floor, Al Barsha 1
SCALE: 1:25 PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
01 SEC. (01-01) Sub-Consultant:
SCALE: 1:25

LINKS LINKS
SLAB RFT SLAB RFT SLAB RFT SLAB RFT
Project Name:

DUBAI WATER CANAL


SLAB

SLAB

SLAB

SLAB
3
SAFA A
50 50 50 50
AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN DUBAI-UAE

Project Description:

R.C. COLUMN R.C. COLUMN MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:
02 SEC. (02-02) 04 SEC. (04-04)
SCALE: 1:25 SCALE: 1:25
STRUCTURAL GENERAL DETAILS -
16

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0021 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

1 ELASTOMERIC, CEMENT WATERPROOF COATING 1 REINJECTABLE HOSE


11 1 1 BASEMENT WALL / RETAINING WALL N
10 1
2 GEOTEXTILE 2 PROTECTION SCREED - MIN. 50mm. THICK
2 2 GEOTEXTILE
KEY PLAN
2 3 PVC WATERPROOFING MEMBRANE 2mm. THICK 3 2mm MEMBRANE WELDED TO WATER STOP 3
1 3 PVC WATERPROOFING MEMBRANE 2mm. THICK
3 4 2mm MEMBRANE WELDED TO WATER STOP 4 WATER STOP
4
4 5 WATER STOP 5 GEOTEXTILE 4 2mm MEMBRANE WELDED TO WATER STOP
5
5 2 6 BLINDING SCREED - SMOOTH FINISH 5 WATER STOP
6 HYDROSWELLING WATER BAR WITH PROPER ADHESIVE
3 1 6 6 REINJECTABLE HOSE
7 REINFORCING FIBER MESH
6 7
8 RAFT SLAB 7 PROTECTION BOARD 6mm. THICK
7 4
9 PROTECTION SCREED - MIN. 50mm. THICK 8 RAFT SLAB
5 9 PROTECTION SCREED - MIN. 50mm. THICK
10 BLINDING SCREED - SMOOTH FINISH 8
8 11 PROTECTION BOARD 6mm. THICK 1 REINJECTABLE HOSE 4 2 10 BLINDING SCREED - SMOOTH FINISH
2 PROTECTION SCREED - MIN. 50mm. THICK 9
9 6 3
3 BLINDING SCREED - SMOOTH FINISH
9 3
4 GEOTEXTILE
5
6 2
2 5 PVC WATERPROOFING MEMBRANE 2mm. THICK 10
10 3
6 BLOCKWORK
4
General Notes:
A TYPICAL
SCALE:
TERMINATION DETAIL @ WATER TANK
N.T.S B TYPICAL
SCALE:
LIFT PIT/SUMP PIT DETAIL
N.T.S C TYPICAL
SCALE:
CONSTRUCTION JOINT DETAIL
N.T.S C TERMINATION
SCALE: N.T.S
DETAIL @ PLOT LINE 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
1 1 1 GUNITE SMOOTH SURFACE
1 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
1 GUNITE SMOOTH SURFACE 2 2 GEOTEXTILE SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 2 3 3 PVC WATERPROOFING MEMBRANE 2mm. THICK AT SITE.
3 2 GEOTEXTILE
4 4 2mm MEMBRANE WELDED TO WATER STOP 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
4 3 PVC WATERPROOFING MEMBRANE 2mm. THICK
GROUND LEVEL 5 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
5 4 2mm MEMBRANE WELDED TO WATER STOP 5 WATER STOP
AND RELEVANT SECTIONS OF THE SPECIFICATION.
5 WATER STOP 6 6 INJECTABLE HOSE

SHORING
6 7 PROTECTION BOARD 6mm. THICK

SHORING WALL
6 REINJECTABLE HOSE 7
2 7
7 PROTECTION BOARD 6mm THICK 8 RAFT SLAB
3 1 2 COATS OF ELASTOMERIC, CEMENT BASED
8 9 PROTECTION SCREED - MIN. 50mm. THICK
WATERPROOF COATING 8 RAFT SLAB
9 PROTECTION SCREED - MIN. 50mm. THICK 6 10 BLINDING SCREED - SMOOTH FINISH
2 WATER STOP 8
3 2mm MEMBRANE WELDED TO WATER STOP 10 BLINDING SCREED - SMOOTH FINISH 9
4 9 3
4 GEOTEXTILE 3
5
5 PVC WATERPROOFING MEMBRANE 2mm. THICK
7 6
2
6 PROTECTION BOARD 6mm. THICK 2 10
10

E TERMINATION
SCALE: N.T.S
DETAIL @ GROUND LEVEL D1 TERMINATION
SCALE: N.T.S
DETAIL @ GUNITE DIAPHRAGM WALL D2 GENERAL
SCALE:
SECTION TERMINATION DETAIL
N.T.S

8 9 1 HIGH STRENGTH FLOWABLE EPOXY GROUT


1 REINJECTABLE HOSE MIN. 50mm.
6 1
2 HIGH STRENGTH FLOWABLE EPOXY GROUT 2 PVC WATERPROOFING MEMBRANE 2mm. THICK
1 GEOTEXTILE
MIN. 50mm. 2 3 ADDITIONAL LAYER
4 2 PVC WATERPROOFING MEMBRANE 2mm. THICK 1
3 PVC WATERPROOFING MEMBRANE 2mm. THICK 3 2mm. PVC WATERPROOFING MEMBRANE
5 3 BLOCKWORK 4 PROTECTION SCREED - MIN. 50mm. THICK
2 4 PROTECTION SCREED - MIN. 50mm. THICK
4 4 0
4 PROTECTION SCREED - MIN. 50mm. THICK
5 BLINDING SCREED - SMOOTH FINISH 5 BLINDING SCREED - SMOOTH FINISH 100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS
1 5 BLINDING SCREED - SMOOTH FINISH 5 5 6 GEOTEXTILE AUTHORITY APPROVAL 0 17.08.2017 NS
6 GEOTEXTILE
2 6 HIGH STRENGTH FLOWABLE EPOXY GROUT 4 4
3
6 7 PROFILING WITH HIGH STRENGTH, SHRINKAGE 7 7 PROFILING WITH HIGH STRENGTH, SHRINKAGE Purpose of Issue Rev. Date Appoved
MIN. 50mm. 5 5 2 COMPENSATED CEMENTITIOUS MICRO
COMPENSATED CEMENTITIOUS MICRO CONCRETE
2 7 ADDITIONAL LAYER OF 2mm PVC MEMBRANE 6 CONCRETE Client:
8 REINJECTABLE HOSE JUNCTION BOX
7 7
8 PROFILING WITH HIGH STRENGTH, SHRINKAGE 3 9 REINJECTABLE HOSE VENT PIPES
4 4 COMPENSATED CEMENTITIOUS MICRO CONCRETE 6
5 5
5 8
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
F1 TYPICAL
SCALE:
PILE WATERPROOFING DETAIL WITH INJECTION HOSE
N.T.S F2 TYPICAL
SCALE:
PILE DETAIL ABOVE BLINDING LEVEL
N.T.S
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
F TYPICAL
SCALE:
PILE WATERPROOFING DETAIL
N.T.S
EPOXY BONDED SEAL

HIGH STRENGTH
EPOXY BEDDING PROTECTION BOARD abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
FILLER Hassanicor Building, 6th Floor, Al Barsha 1
GEOTEXTILE PO Box 54115 Dubai, UAE
DETAIL 'G1' P: +971 4 3997758 F: +971 4 3997759
4 WATER BAR
PVC WATERPROOFING MEMBRANE 2mm. THICK
Sub-Consultant:
1 G1 DETAIL
SCALE:
'G1'
N.T.S HIGH STRENGTH
EPOXY BEDDING
2 CONCRETE SLAB
EPOXY BONDED SEAL SOIL FILL
3 WATER STOP
4
4 FILLER
3 ADDITIONAL LAYER OF
5 2mm PVC MEMBRANE WATER BAR
1 PROTECTION SCREED - MIN. 50mm. THICK WELDED TO WATER STOP WATER STOP
6 REINJECTABLE HOSE
2 BLINDING SCREED - SMOOTH FINISH ADDITIONAL LAYER OF
PVC WATERPROOFING
Project Name:
1 3 GEOTEXTILE 2mm PVC MEMBRANE WELDED
REINJECTABLE HOSE MEMBRANE 2mm. THICK
DUBAI WATER CANAL
TO WATER STOP
2 4 PVC WATERPROOFING MEMBRANE 2mm. THICK
GEOTEXTILE
3 5 BLOCKWORK / SHUTTERING BLINDING
6 GROUND BEAM SAFA A
DUBAI-UAE
H TYPICAL
SCALE:
GROUND BEAM DETAIL
N.T.S

Project Description:

G EXPANSION
SCALE:
JOINT DETAIL VERTICAL & HORIZONTAL
N.T.S
MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


17

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0022 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN

1 4 1

PROTECTION BOARD 6mm. THICK


1 REINJECTABLE HOSE

2 WATER STOP PVC WATERPROOFING

MEMBRANE 2mm. THICK


3 2mm. PVC WATERPROOFING MEMBRANE WELDED TO WATER STOP
2 GEOTEXTILE
4 CONCRETE RAFT
WELDING

5 GEOTEXTILE

6 PVC WATERPROOFING MEMBRANE 2mm. THICK JUBILEE CLIP

JOINT SEALANT
BLINDING SCREED - SMOOTH FINISH
9
7

5
3
9
8 PROTECTION SCREED - MIN. 50mm. THICK

6
10 DEEP WELL STEEL CAP
9
7
10 POLYURETHANE SEALANT

11

15 12

13
11

12
JUBILEE CLIP

WATERPROOFING SWELLING PASTE


General Notes:
8
13 HIGH STRENGHT FLOWABLE EPOXY GROUT MIN. 50mm.
1. DO NOT SCALE FROM THIS DRAWING.
7
14 ADDITIONAL LAYER OF 2mm. PVC WATERPROOFING MEMBRANE

14
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
15 PROTECTION BOARD 6mm. THICK
PVC WATERPROOFING
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
MEMBRANE 2mm. THICK BY THE ENGINEER.

WATERPROFING 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SWELLING PASTE
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 ADDITIONAL PIECE OF MEMBRANE AT SITE.
WELDED TO THE MAIN MEMBRANE

J DEWATERING
SCALE: N.T.S
WELL WATERPROOFING DETAIL
PVC WATERPROOFING
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
MEMBRANE 2mm. THICK
AND RELEVANT SECTIONS OF THE SPECIFICATION.
GEOTEXTILE

PROTECTION BOARD 6mm. THICK

CEMENT RENDER

M PIPE PENETRATION DETAIL - ABOVE WATER LEVEL


JOINT SEALANT

SCALE: N.T.S

7 ALUMINIUM FLASHING/TERMINATION STRIP

MECHANICAL FIXING

PROTECTION BOARD 6mm. THICK

PROTECTION BOARD 6mm. THICK

LANDSCAPING / PLANTING
GEOTEXTILE

PVC WATERPROOFING

100mm. THICK RC CAP MEMBRANE 2mm. THICK

WELDING
SLOPED LIGHT WEIGHT CONCRETE,

DENSITY 13 kN/m3 JOINT SEALANT

6
JUBILEE CLIP

PVC WATERPROOFING MEMBRANE


HIGH STRENGTH FLOWABLE
2mm. THICK
EPOXY GROUT min. 50mm

GEOTEXTILE 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


CONCRETE SLAB AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

K WATERPROOFING
SCALE: N.T.S
DETAILS BELOW LANDSCAPING @ GROUND FLOOR WITH UPSTAND
PVC WATERPROOFING
MEMBRANE 2mm. THICK

5
MEYDAN L.L.C
WATERPROOFING
SWELLING PASTE

P.O. Box 9305, Dubai , UAE.


ADDITIONAL PIECE OF MEMBRANE
WELDED TO THE MAIN MEMBRANE
T: +9714 3270000 F: +9714 3270007
1 E: info@dubairacingclub.com W: www.dubairacingclub.com
2

3
PVC WATERPROOFING
MEMBRANE 2mm. THICK Principal Consultant:
4
GEOTEXTILE

PROTECTION BOARD 6mm. THICK

1 LANDSCAPING / PLANTING abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
2 100mm. THICK RC CAP
Hassanicor Building, 6th Floor, Al Barsha 1
3 2mm. THICK PVC WATERPROOFING MEMBRANE PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 4 GEOTEXTILE

5 SLOPED LIGHT WEIGHT CONCRETE, DENSITY 13 kN/m3


Sub-Consultant:
6 CONCRETE SLAB

N PIPE
SCALE:
PENETRATION DETAIL - BELOW WATER LEVEL
N.T.S
5

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE
L WATERPROOFING
SCALE: N.T.S
DETAILS BELOW LANDSCAPING @ GROUND FLOOR
Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


18

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0023 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

PRIMARY BEAM MAX SECONDARY BEAM PRIMARY BEAM SECONDARY BEAM


MAX TAPER STIFFENER PLATE SAME

50 TYP.
NOTCHLENG20 NOTCHLENG 20 THICKNESS AS BEAM FLANGE

50 TYP.
16 MINIMUM. (TOP & BOTTOM SIMILAR) N
10 TH TH KEY PLAN
N STIFFENER PLATE SAME
N THICKNESS AS BEAM FPBW
FLANGE 16
2d 75 FPBW

20
FPBW

70 TYP. d2
MINIMUM. (TOP AND

70 TYP. d2
MAX.
BOTTOM FILLET WELD

60
SIMILAR) (THICKNESS=PLATE THICKNESS)

50
FILLET WELD ALL FPBW
100 n + 12

L
ROUND

L
TYP. TOP &

D
FILLET WELD ALL ROUND (THICKNESS = BOTTOM

20
BOTH 'T') (OR
9 SIDE (THICKNESS='T') (OR
A A THICKNESS =
ERECTION BOLTS
d2 0.8T CFW THICKNESS = '0.8T' FOR '0.8T' FOR Fab.) I

d2
0.8T CFW FPBW AS REQUIRED.
Fab. ) I

50
d1 d1 50 PLATE THICKNESS CONNECTION PLATE
FIN PLATE FIN PLATE = 'T' + 6mm
W THICKNESS "T" THICKNESS "T" PLATE THICKNESS (T) = General Notes:
W BEAM WEB THICKNESS + 6 mm.

60
1. DO NOT SCALE FROM THIS DRAWING.
M20 ERECTION SECONDARY BEAM
END PROJECTION=T END PROJECTION=T BOLTS AS REQUIRED (WITH WEB THICKNESS 'T') ELEVATION 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
FPBW NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
NOTCH BOTTOM NOTCH BOTTOM NOTE BY THE ENGINEER.
FLANGE AS REQUIRED FLANGE AS REQUIRED ONE SIDED CONNECTION IS SHOWN. TWO
MAX LENGTH 'N' 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
MAX LENGTH 'N' SIDED SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 PRIMARY BEAM AT SITE.
CONNECTION IS SIMILAR.
BEAM TO BEAM 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
BOLTED BEAM TO BEAM FIN PLATE BOLTED BEAM TO BEAM FIN PLATE WELDED MOMENT CONNECTION WELDED MOMENT CONNECTION ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
CONNECTION (SINGLE COLUMN BOLTS) CONNECTION (DOUBLE COLUMN BOLTS) N.T.S. BEAM TO COLUMN WEB
N.T.S. N.T.S. WITHOUT COVER PLATE
CL COLUMN N.T.S.
STIFFENER PLATE
TO COL. WEB
FILLET WELD
FPBW (THICKNESS=PLATE THICKNESS)
7 FPBW FPBW FPBW BEAM
FILLET WELD FIN PLATE
20 THICKNESS 'T'
20

(THICKNESS=PLATE THICKNESS)

50 TYP.
30

FILLET WELD

T1
20

20
(THICKNESS=PLATE THICKNESS)

30

30
COVER PLATES CONNECTION PLATE
CONNECTION PLATE
PLATE THICKNESS (T) =
STIFFENER PLATE SAME BEAM WEB THICKNESS + 6
100

70 TYP. 40
THICKNESS AS BEAM

30

20
n + 12
30

FLANGE FPBW TYP. TOP &


20

30
BOTTOM

20
16 MINIMUM. (TOP &

T1

0.6 D MIN.
BOTTOM 'e'(TOP & BOTTOMFPBW
ERECTION BOLTS FLANGE OFFSET)
6 SIMILAR) FPBW
AS REQUIRED. WEB CONNECTION FPBW

D
PLATE AS REQUIRED.
FOR THICKNESS OF TOP & ELEVATION
BOTTOM STIFFENER PLATE SEE NOTE 2. 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

40
NOTE ELEVATION AUTHORITY APPROVAL 0 17.08.2017 NS
NOTES: Purpose of Issue Rev. Date Appoved
ONE SIDED CONNECTION IS SHOWN. TWO 1. WHEN TOP OR BOTTOM FLANGES ARE OFFSET AND 'e' IS GREATER THAN 75 mm 40 40 MIN.
SIDED PROVIDE STIFFENER PLATE OPPOSITE EACH FLANGE. IF 'e' IS LESS THAN OR Client:
CONNECTION IS SIMILAR. EQUAL TO 75 mm SLOPE STIFFENER PLATE BETWEEN THE OFFSET FLANGES.
WELDED MOMENT CONNECTION 2. STIFFENER PLATE SAME THICKNESS AS THICKEST FLANGE FRAMING AT THIS
PLANE. GRADE OF STIFFENER PLATE SAME AS FRAMING BEAM, 16 mm MIN.
5 BEAM TO COLUMN WEB COLUMN FLANGE/ COVER PLATE
MEYDAN L.L.C
WITH COVER PLATE WELDED MOMENT CONNECTION P.O. Box 9305, Dubai , UAE.

N.T.S. STIFFENER PLATES TO


BEAM TO COLUMN FLANGE T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
COL. WEB & FLANGES N.T.S. Principal Consultant:
(TYP. TOP & BOTTOM)
BOLTED BEAM TO COLUMN (FLANGE)
STIFFENER PLATES
TO COL. WEB & FLANGES ALL STIFFENERS ALIGNED WITH TOP FIN PLATE CONNECTION abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
AND BOTTOM OF CONNECTION PLATE. N.T.S. www.ae-7.com
(TYPICAL TOP & BOTTOM) Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:
STIFFENERS ALIGNED WITH TOP
AND BOTTOM OF CONNECTION PLATE

FIN PLATE TO
WEB AND
STIFFENERS

Project Name:

3
DUBAI WATER CANAL
A SAFA A
OR
DUBAI-UAE

Project Description:

SKEWED BEAM CONNECTION MIXED USE DEVELOPMENT


TO COLUMN WEB SKEWED BEAM CONNECTION (RETAIL & RESIDENTIAL)
N.T.S. TO COLUMN FLANGE
N.T.S. PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


19

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0024 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

SECONDARY BEAM
MAX (450x250x16 RHS OR
PRIMARY BEAM NOTCHLENG20 500x300x16x16 FAB. RHS)
TH
N
10 N KEY PLAN

38 48
CL COLUMN
BEAM CONNECTION
PLATE AS REQUIRED

66
SECONDARY BEAM
(450x250x16 RHS)

66
FPBW

66
PRIMARY BEAM

38
9 CL BEAM CL BEAM

104
CONNECTION PLATE AS General Notes:
FIN PLATE ERECTION AID AND
65 48 THICKNESS "T"
15 (BOTH SIDE) FILLET WELD BACKING 1. DO NOT SCALE FROM THIS DRAWING.
STIFFENER PLATES STRIP
TOP & BOTTOM ERECTION BOLTS AS 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
REQUIRED BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


PLAN SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
ELEVATION PLAN AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
BOLTED BEAM TO BEAM FIN PLATE AND RELEVANT SECTIONS OF THE SPECIFICATION.

CONNECTION
N.T.S.

CL PRIMARY BEAM
SECONDARY BEAM
n+12

7
MAIN BEAM

45°
MIN
STIFFENER PLATE

.
THICKNESS "T"
A
n+12

6 SIDES.
A

FOR CONNECTION

A
6 M20 ERECTION REFER TO TYPICAL
BOLTS AS REQUIRED. FIN PLATE DETAIL
NOTCH BEAM
IF REQUIRED. 0
20 MAX 100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS
PLAN A-A AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
BEAM TO BEAM
WELDED CONNECTION BEAM SKEW (GREATER THAN 45°) Client:

N.T.S. N.T.S.
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
BOLTS SHIM PLATE Principal Consultant:
C
L COLUMN

CL COLUMN TAPER STIFFENER PLATE abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
TOP AND BOTTOM www.ae-7.com
FPBW Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
CONNECTION PLATE COVER PLATE
BOLTS SPLICES PLATE Sub-Consultant:
STIFFENER PLATE CL BEAM
TOP AND BOTTOM
CL BEAM STIFFENERS

CONNECTION PLATE
AS ERECTION AID
ERECTION BOLTS AND BACKING STRIP
Project Name:
AS REQUIRED.
FPBW (TYP.) ERECTION BOLTS
3 3 SIDES STIFFENER FILLET
AS REQUIRED. DUBAI WATER CANAL
BOLTS SHIM PLATE PLATE TO COL. WELD SAFA A
DUBAI-UAE
ELELVATION SECTION PLAN PLAN Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
TYPICAL STEEL BEAM SPLICES CONNECTIONDETAIL PLOT 01 / 3435338
2 N.T.S. BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

STRUCTURAL GENERAL DETAILS -


20

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0025 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N12-200 'L' BARS EACH


SIDE OF BLOCKOUT BENT
ONE R10 TIE EXTRA DOWN INTO SLAB AFTER ONE R10 TIE EXTRA
EACH SIDE FOR 2N12 TOP & BOTTOM CONTINUOUS ONE R10 TIE EXTRA 2N12 TOP & BOTTOM CONTINUOUS STRESSING EACH SIDE FOR
4 OR 5 STRANDS 15.2Ø LAP 350, 1000 MINIMUM LENGTH EACH SIDE FOR LAP 350, 1000 MINIMUM LENGTH 4 OR 5 STRANDS 15.2Ø N
10 FOR SINGLE DUCT LOCATIONS 4 OR 5 STRANDS 15.2Ø FOR SINGLE DUCT LOCATIONS KEY PLAN
SECURE END OF DUCT
WITH DENSOTAPE
(TYPICAL)
PLACE INNERMOST BAR
1 2 HARD AGAINST SPACER

300 LAP
---- ---- PLATE AS SHOWN 1

450

400
----

ONIONS TO BE SET OUT


PLACE INNERMOST BAR USING SPACER PLATE
9 HARD AGAINST SPACER MINIMUM SPACING 75mm.
PLATE AS SHOWN
2R10 TIES AT 50mm C/C,
THEN AT 400 C/C. PLACE EXTRA N12 TOP & BOTTOM 2R10 TIES AT 50mm C/C
EXTRA N12 TOP & BOTTOM INNERMOST TIE HARD 2N12 TRIMMERS TOP E/F
FOR 4 & 5 STRANDS 15.2Ø AGAINST CASTING FOR 4 & 5 STARNDS 15.2Ø THEN AT 400 C/C X1500 LONG TYPICAL FOR
ALL PAN STRESSING
General Notes:
POCKETS INCLUDING
POCKETS IN BANDS 1. DO NOT SCALE FROM THIS DRAWING.

TYPICAL LIVE END UNSUPPORTED SLAB EDGE TYPICAL DEAD END UNSUPPORTED SLAB EDGE 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

01 02 SCALE N.T.S
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
N.T.S
INTERNAL STRESSING SLAB POCKET DETAIL BY THE ENGINEER.
SCALE

01 SCALE N.T.S
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

370
50
450 200
7

30
GROUT TUBE

80
R10 CLOSED TIES SPACER PLATE

140
R10 CLOSED TIES

=
=
=

3N12 TOP & BOTTOM 2R10-50 TIES

=
1000 LONG MINIMUM EACH SIDE
=

200 OR CONTINUOUS 500 LAP


2N12 TOP & BOTTOM 2N12 TOP & BOTTOM WHERE REQUIRED
200 X 1000 MINIMUM
X 1000 MINIMUM
6

SECTION (1) SECTION (2) SECTION (1)


03 SCALE N.T.S 04 SCALE N.T.S 03 SCALE N.T.S

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

600
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
2N16 AT EACH ANCHOR
1 1 700

200
---- ----

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PLACE INNERMOST BAR PLACE INNERMOST BAR PO Box 54115 Dubai, UAE
HARD AGAINST ANCHOR HARD AGAINST ANCHOR P: +971 4 3997758 F: +971 4 3997759
4 PLATE AS SHOWN PLATE AS SHOWN Sub-Consultant:

LIVE END AT POUR STRIP DETAIL TYPICAL TENDON COUPLER DETAIL 2N16 1000 LONG AT
01 01 SCALE N.T.S
SCALE N.T.S EACH ANCHOR
200 4N12 T & B,
5N12-60,
6N12-60 FOR 5N16 T & B FOR
125 BEAMS >550D BEAMS >550D
2N12 TOP & BOTTOM Project Name:
SEE PLAN FOR BAR SIZE SEE PLAN FOR BAR SIZES 1000 LONG
5N12 N16-200 U.N.O AT SLAB N16-200 U.N.O AT SLAB REFER TO LIVE
03
TYPICAL DEAD END BEAM DETAIL DUBAI WATER CANAL
40
3 N20-200 U.N.O AT BEAM N20-150 U.N.O AT BEAM END DETAIL U.N.O SCALE N.T.S

(15.2Ø STRANDS) SAFA A


DUBAI-UAE

Project Description:
25

REINFORCEMENT SIMILAR 2R10 TIES AT


MIXED USE DEVELOPMENT
5N12 TO TYPICAL LIVE END DETAIL 50 C/C EACH SIDE (RETAIL & RESIDENTIAL)
1200 NTS 1200 - POUR STRIP 1200 NTS UNLESS NOTED OTHERWISE
PLOT 01 / 3435338
2 SECTION (1) BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
02
SECTION (1)
SCALE N.T.S

02 SCALE N.T.S
Drawing Title:

STRUCTURAL GENERAL DETAILS -


21

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0026 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN
R10 CLOSED TIES ENDS SQUARED BY
N16-250 TOP & BOTTOM 2N12 TOP & BOTTOM
ACROSS JOINT 3000 LONG SPACER PLATE EITHER SIDE BENDING AS SHOWN

1 2
---- ----
1N16 TOP & BOTTOM LIVE OR DEAD ANCHOR
EITHER SIDE OF JOINT EITHER SIDE OF JOINT
9 LAP 450

ENDS SQUARED BY
BENDING AS SHOWN
General Notes:
TYPICAL REINFORCEMENT AT C.J. IN SLAB
02 SCALE N.T.S
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

ALTERNATIVE LIVE END UNSUPPORTED SLAB EDGE ALTERNATIVE DEAD END UNSUPPORTED SLAB EDGE 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 01 SCALE N.T.S 02 SCALE N.T.S
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
100 350 R10 HELIX OF 6 TURNS 350 50
50
AT 70 PITCH R10 HELIX OF 6 TURNS

110
4N20 TOP & BOTTOM AT 70 PITCH

110
ACROSS JOINT 3000 LONG ROUGHENED SURFACE 290 SPACER PLATE
290

1N16 TOP & BOTTOM LIVE OR DEAD ANCHOR


EITHER SIDE OF JOINT EITHER SIDE OF JOINT 3N12 TOP & BOTTOM CONTINUOUS 3N12 TOP & BOTTOM CONTINUOUS
LAP 450 LAP 350, 1000 MINIMUM LONG FOR LAP 350, 1000 MINIMUM LONG FOR
SINGLE DUCT LOCATIONS SINGLE DUCT LOCATIONS

SECTION (1)
TYPICAL REINFORCEMENT AT C.J. IN BEAMS OR THICKENING 03 SCALE N.T.S SECTION (2)
04 SCALE N.T.S 04 SCALE N.T.S

100 50 2N20 AT EACH ANCHOR


1400 200 400 600 400 200
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
200

AUTHORITY APPROVAL 0 17.08.2017 NS


Purpose of Issue Rev. Date Appoved
Client:

3 1 2 4

200
5
2N16 1000 LONG MEYDAN L.L.C

VARIES
AT EACH ANCHOR P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
200 E: info@dubairacingclub.com W: www.dubairacingclub.com

4N12 T & B, 5N12-60, Principal Consultant:


5N16 T & B FOR 6N12-60 FOR
BEAM >550D BEAMS >550D
TYPICAL LIVE END BEAM DETAIL
04 SCALE N.T.S
1800
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
(15.2Ø STRANDS) Hassanicor Building, 6th Floor, Al Barsha 1

STRESSING DETAILS IN SLAB BANDS (FOR 15.2mm MONO-STRANDS U.N.O.) PO Box 54115 Dubai, UAE
4 01 SCALE N.T.S
Sub-Consultant:
P: +971 4 3997758 F: +971 4 3997759

NUMBER & COMBINATION OF ANCHORS MAY VARY ( 1 SIGNIFIES ORDER OF STRESSING)


2N16
4N12 T & B, 700
5N16 T & B FOR 200 350 350 350 350 200
200

BEAMS >550D

Project Name:

3 4 2 1 3 5 DUBAI WATER CANAL

200
50 200 2N16 SAFA A
5N12-60 800 LONG

VARIES
DUBAI-UAE

TYPICAL LIVE END BEAM DETAIL AT STRESSING POCKET Project Description:


05
MIXED USE DEVELOPMENT
SCALE N.T.S

(15.2Ø STRANDS)
1800 (RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 STRESSING DETAILS IN SLAB BANDS WITH 5 TENDONS (FOR 15.2mm MONO-STRANDS U.N.O.) BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
02 SCALE N.T.S

NUMBER & COMBINATION OF ANCHORS MAY VARY ( 1 SIGNIFIES ORDER OF STRESSING) Drawing Title:

STRUCTURAL GENERAL DETAILS -


22

Scale Drawn Checked Approved Size


AA MA NS
1 N.T.S A1
26.05.2016 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-01-00-SG0027 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

N
11

Q
N
10 KEY PLAN

T E= 491007.383
L IMI N= 2787286.659
OT
PL

1.D 01

0
1.C 950

820
0
1.B 0 02
220
9
0
1.A 950

820
0
IT
N LIM 1.01 General Notes:
TIO
IT VA
LIM CA
OT EX
PL 1. DO NOT SCALE FROM THIS DRAWING.

820
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

0
E= 490975.312
1.02 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
N= 2787307.045
BY THE ENGINEER.
E= 491042.909
N= 2787150.747 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 PLOT LIMIT

820
AT SITE.

0
1.03 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

820
IT 2.12
LIM

0
N 2.10 2.11
TIO 1.04
AVA 2.09 9500
E XC 2.08 2200 2.A
9500
2800

820

8200
0
1.05 EXCAVATION LIMIT
7
2.B

820
0

8200
1.06

2.C

820
0
1.07

8200
E= 490979.612
N= 2787191.032

6 2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.D

8200 8200 8200 8200 8200 12300


E= 490963.151
E= 490973.845

8200
N= 2787215.853
N= 2787194.156 EXCAVATION LIMIT
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
PLOT LIMIT EXCAVATION LIMIT AUTHORITY APPROVAL 0 17.08.2017 NS
2.E
Purpose of Issue Rev. Date Appoved
Client:

8200
1.08

2.F
2.E'
5
8200

MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.

8200
T: +9714 3270000 F: +9714 3270007
9500

E: info@dubairacingclub.com W: www.dubairacingclub.com
1.09

2.G
Principal Consultant:

2.F'
2200
11200

8200
2.G'
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
2.H Hassanicor Building, 6th Floor, Al Barsha 1
9500

1.10 PO Box 54115 Dubai, UAE


P: +971 4 3997758 F: +971 4 3997759
4 E= 490984.304
N= 2787111.297 Sub-Consultant:
PLOT LIMIT
8200

2.H'

1.11

EXCAVATION LIMIT E= 490975.881


N= 2787121.246
PLOT LIMIT E= 490968.072
E= 490960.908 N= 2787131.685
E= 490954.413 N= 2787142.576
2200 14500 5600 N= 2787153.879
Project Name:
E= 490930.670
E= 490919.691
N= 2787199.197
N= 2787220.255
3
1B' 1C' 03 04 DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


-1.525 DMD -3.025 DMD
(RETAIL & RESIDENTIAL)
-0.525 DMD -3.725 DMD PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
-1.625 DMD -4.025 DMD
Drawing Title:
-1.845 DMD -4.825 DMD

-2.045 DMD +1.075 DMD EXCAVATION PLAN


-2.240 DMD +1.475 DMD

Scale Drawn Checked Approved Size


-2.245 DMD +1.675 DMD AA MA NS
1 1 : 350 A1
EXCAVATION PLAN -2.440 DMD +1.775 DMD
15.06.2017 24.08.2017 24.08.2017
1 SCALE 1 : 350
Drawing Number Rev.
-2.625 DMD +2.975 DMD
14011603-01-00-SE0100 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

N
11

Q
N
10 KEY PLAN

T E= 491007.383
L IMI N= 2787286.659
OT
PL

1.D 01

0
1.C 950

820
0
9 1.B 0 02
220

0
1.A 950

820
General Notes:

0
1.01
T
L IMI 1. DO NOT SCALE FROM THIS DRAWING.
OT
PL
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

820
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

0
E= 490975.312 BY THE ENGINEER.
N= 2787307.045 1.02
E= 491042.909 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
N= 2787150.747 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
PLOT LIMIT

820
0
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
1.03 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

820
2.12

0
1.04 2.10 2.11
9500
2.08 2.09 2200
9500 2.A
2800

820

8200
0

SP0
1
7 1.05

999
b
2.B

820

SP0
1 a
0

999

8200
1.06

1 1 2.C

820
SP0999c SP0999b

0
1.07

8200
E= 490979.612
N= 2787191.032
6
2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.D

8200 8200 8200 8200 8200 12300


E= 490963.151
E= 490973.845

8200
N= 2787215.853 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
N= 2787194.156
AUTHORITY APPROVAL 0 17.08.2017 NS
PLOT LIMIT
2.E Purpose of Issue Rev. Date Appoved
Client:

8200
1.08
5 2.F
2.E'
MEYDAN L.L.C
8200

P.O. Box 9305, Dubai , UAE.


T: +9714 3270000 F: +9714 3270007

8200
E: info@dubairacingclub.com W: www.dubairacingclub.com
9500

1.09 Principal Consultant:


2.G

2.F'
2200
11200

8200
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
2.G'
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
2.H
9500

P: +971 4 3997758 F: +971 4 3997759


4 1.10
E= 490984.304 Sub-Consultant:
N= 2787111.297
PLOT LIMIT
8200

2.H'

1.11

E= 490975.881
N= 2787121.246
PLOT LIMIT E= 490968.072
E= 490960.908 N= 2787131.685 Project Name:
E= 490954.413 N= 2787142.576
2200 14500 5600 E= 490930.670 N= 2787153.879

3
E= 490919.691
N= 2787220.255 1B' 1C' 03 04
N= 2787199.197 DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

LEGEND: BASEMENT 01 LEVEL - FRAMING &


R.C. COLUMN
R.C. WALL
PILE CAPS PLAN - OVERALL
PLANTED COLUMN / WALL

NOTE: Scale Drawn Checked Approved Size


1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS AA MA NS
1 2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS 1 : 350 A1
3. FOR FAOUNDATION DETAILS REFER TO DWG. 00-S5101 TO DWG. 00-S5109 08.06.2017 24.08.2017 24.08.2017
BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - OVERALL 4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO DWG. 00-S5508
1 SCALE 1 : 350
5. FOR RAMP DETAILS REFER TO DWG. 00-S5601 TO DWG. 00-S5603
6. FOR WATER TANK DETAILS REFER TO DWG. 00-S5901
Drawing Number Rev.
7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
8. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
14011603-01-00-SP0999 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

PLOT LIMIT
DUBAI MUNICIPALITY STAMP:

860
750

N
11 1.D 01

__
___
_1__

PC
0
145

26
150
S5901

Q
0
0
950

820
1.C
750

0
5
107

PC

200
mm

27
X300 PIT
1.B 00 N
X6 DRAI
600 N

500
02

PC
0
220 KEY PLAN

27
10 A
5
122 mm
400

800
X
600 600
0X PIT 00 00x SSL

145
0 00 8
950
6 AIN 0x6 ING 50

0
DR G 80 0 SSL PEN L -1.1

PC
150 N 0 O E

27
I 9 V
1.A EN -0. TL
E 2
3 OP VEL A

350
LE

820
S5106
AT 0

PC
0
115
S5106

0
106

3
0

750
135 TRENCH 1.01

PC

PC
2300X300X300

31

27
9

200
5
325

PC

340
3

900

-6.0
PLOT LIMIT
575 IT 500

00
P P 00x2

SS
528
9 M
SU 00x20 General Notes:

L
5
S5108 20

820
0 1. DO NOT SCALE FROM THIS DRAWING.
115

0
0

PC
0 416

1
310 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
PC

PC
110 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
31

750
0 BY THE ENGINEER.
1.02

PC
0 2

750

27
375 625 150 S5105
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8

500
AT SITE.
TRENCH

mm
171
2300X300X300 750 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

TH
285

750
0
MP

ICK
-3.5
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
RA

PC

.R
AND RELEVANT SECTIONS OF THE SPECIFICATION.

00
3

AF
SS

T
L
2
PC

820
PC
31

0
115

0
5
S5106

5
327

750
1.03

-3.5

PC
750

00
PC

27
0 150

SS
444
3

L
190
7 150 0
TRENCH 110

750

900
7300X300X300
750

PC
192

3
5

820
0
115

PC
PC

0
3
27

PC
600

23

750
1.04
700

900

PC
300

27
-6.3

0
100
00

925
SS

mm 750
L

6 118
5 600

750
0X
750

0
X6 IT

PC
600 AIN P

1
DR
2

820
2 0
115
PC

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

0
S5106
27

S5106
AUTHORITY APPROVAL 0 17.08.2017 NS
ST 00
1-0
2

PC

PC

750
Purpose of Issue Date Appoved
2

Rev.
13

5
0 1.05
155

750

SP0
PC
Client:

1
27

999
b
600
875

750

750
750

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
PC
27

820
T: +9714 3270000 F: +9714 3270007
PC

0
115
E: info@dubairacingclub.com W: www.dubairacingclub.com

0
9

500mm THICK.
750

Principal Consultant:

PC
0 RAFT-
260

750
1.06
0
155

750

PC
500

27
mm
TH
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
750

ICK
0 www.ae-7.com
110

900
Hassanicor Building, 6th Floor, Al Barsha 1

RA
VA
PC

FT
PO Box 54115 Dubai, UAE

R.
750

19

P: +971 4 3997758 F: +971 4 3997759


4
Sub-Consultant:
PC

820
27

PC

0
115

0
9

PC
775

750
23
0
750
800 155 3 1.07

PC
27
138
700
S5105

5
PC
19

750 Project Name:

750
750

TRENCH
3 4200X300X300 2
DUBAI WATER CANAL
SAFA A
PC

0
115
S5106

PC
PC

5
27

2
970 DUBAI-UAE

145
S5106
750

750
150

0
0 TRENCH
155
750

4200X300X300 Project Description:


9
S5108 MIXED USE DEVELOPMENT
PC

300
3

20 (RETAIL & RESIDENTIAL)


750

725

860
PLOT 01 / 3435338

5
1 1
2 S5107
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
PC
PC

S5107
9
27

0
-4.5

145 Drawing Title:


00
750

150
SS

LEGEND:
L

R.C. COLUMN
BASEMENT 01 LEVEL - FRAMING &
R.C. WALL PILE CAPS PLAN - PART A
PLANTED COLUMN / WALL

NOTE: Scale Drawn Checked Approved Size


1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS AA MA NS
1 2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS 1 : 150 A1
3. FOR FAOUNDATION DETAILS REFER TO DWG. 00-S5101 TO DWG. 00-S5109 08.06.2017 24.08.2017 24.08.2017
4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO DWG. 00-S5508

BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART A 5. FOR RAMP DETAILS REFER TO DWG. 00-S5601 TO DWG. 00-S5603 Drawing Number Rev.
1 SCALE 1 : 150
6. FOR WATER TANK DETAILS REFER TO DWG. 00-S5901
7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
8. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
14011603-01-00-SP0999a 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

N
11 1.B 1.C 1.03 1.D 1.04

Q
1.05

750

750

SP0
1 a
0
950

999
N
KEY PLAN
PC

10 115
0
9

PC
5

750
0
220 1.06

750

PC
500

27
mm
TH
750 B

ICK
0
110

900
RA
VA
0
950

FT
R.
1
SP0999c
PC

1.A 0
115
9

PC

750
23
0 1.07
155 750
3

PC
27
General Notes:

138
S5105

5
750 1. DO NOT SCALE FROM THIS DRAWING.

750
TRENCH 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
4200X300X300 2
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
PC

0
115 2.01 2.02 2.03 2.04 2.05
S5106

PC
0
9

PIT x250 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

5
MP 2000
970 U SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 S 00x AT SITE.
20

145
750

750
150

0
0 8200 8200 8200 8200
155 TRENCH 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
750

PC
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
4200X300X300

27
9 AND RELEVANT SECTIONS OF THE SPECIFICATION.

S5108
PC

300
3

20

725
PC27

860
5
1 1 2 2
S5107
PC

S5107 750 S5106 PLOT LIMIT S5106


9

0
-4.5

145
00
750

750
7 150
SS

PC
L

14
725

150

1150
1150

1150

1150

1150
PC27
0 PC3
190 PC27 PC27 PC27
PC27
150 PC2 750 750 750 750 750
PC

3600
SUMP PIT 9
750

OPENING 800x600
3

PC

2000x2000x2500
145

TRENCH AT LEVEL -1.300 SSL 600X600X300mm


750

S5108
0

DRAIN PIT 1150 920


3650X300X300
PC

3175
750

750
2
3

1.08
PC

TRENCH S5107 PC3


27

3660
3650X300X300 PC15
TRENCH 775

1850
1550X600X400mm
150 1 ESCALATOR PIT 750 750
6 1750X300X300 DRAIN PIT
316

4250x3200x1100 2.E'

100

100
0

450
TRENCH S5107 750

1050
750

2300X300X300 600X600X300mm
PC
750
8200

0 DRAIN PIT
405
3

525 1 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


0 PC4
119 -5.600 SSL
S5107 AUTHORITY APPROVAL 0 17.08.2017 NS
PC3
OPENING 800x600 PC19 PC19 Purpose of Issue Rev. Date Appoved
1150 PC5 ST2-01
2650 AT LEVEL -1.300 SSL 7
657

PC3 200
PC

Client:

9500
2
1350
0

S5108
27

750

750

1.09 S5106
PC3
750

750

450
PC5
5 800 750 750 750
MEYDAN L.L.C
2650

-6.300 SSL
725 600X600X600mm 1 P.O. Box 9305, Dubai , UAE.
DRAIN PIT S5107 275 T: +9714 3270000 F: +9714 3270007

1350
PC

5 E: info@dubairacingclub.com W: www.dubairacingclub.com
119
3

2.F'

150 1900 150

300 1750 150

300 1750 150


PC3 PC3 PC17 PC3 Principal Consultant:
PC3

2200
750 900 900
11200

ST1-01 PC3 700

1100
PC

200
1900

150
500mm THICK. RAFT 275 2.G'
27

750
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
700 -4.500 SSL www.ae-7.com
1500

PC3 PC1 Hassanicor Building, 6th Floor, Al Barsha 1


PC3 PC6
PC1 PO Box 54115 Dubai, UAE
PC16 500mm THICK. RAFT
PC3 PC3 725 P: +971 4 3997758 F: +971 4 3997759
4 650 750
Sub-Consultant:
2300

-4.500 SSL
2600

0 750
119
1300

750

9500
300

1.10
750

PC3 500mm THICK. RAFT


PC5
PC

2 PC5 PC3 850


27

-4.500 SSL
S5106 900 900 900 900
275

TRENCH
Project Name:
2300X300X300
8200

1500

PC24
2.H'
100

100
200

200
300

3 PC3
PC1 PC1 PC1
PC1
DUBAI WATER CANAL
750

2455
SAFA A

2555
0

2760
150
3060
2500

3065

325 275 750 750


750 750
750
1850

DUBAI-UAE
PC27
750
600

600

PC27
1.11 PC27
PC10 PC27
PC

PC21 PC32 PC27 Project Description:


26

PC8

1800
1
1
1 MIXED USE DEVELOPMENT
1800

S5106
S5106
(RETAIL & RESIDENTIAL)
1800

S5106 PLOT LIMIT

PLOT 01 / 3435338
2 PLOT LIMIT BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:
LEGEND:
2200 14500 5600
R.C. COLUMN BASEMENT 01 LEVEL - FRAMING &
1B' 1C' 03 04 R.C. WALL PILE CAPS PLAN - PART B
PLANTED COLUMN / WALL

NOTE: Scale Drawn Checked Approved Size


1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS AA MA NS
1
BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART B 2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS
3. FOR FAOUNDATION DETAILS REFER TO DWG. 00-S5101 TO DWG. 00-S5109
1 : 150
08.06.2017 24.08.2017 24.08.2017
A1
1 SCALE 1 : 150
4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO DWG. 00-S5508
5. FOR RAMP DETAILS REFER TO DWG. 00-S5601 TO DWG. 00-S5603 Drawing Number Rev.
6. FOR WATER TANK DETAILS REFER TO DWG. 00-S5901
7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
8. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308 14011603-01-00-SP0999b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


2.12

N
11
2.11
2.10

Q
2.09 9500 2.A
2.08
2200
9500
2800

8200
N
10 KEY PLAN

PLOT LIM
2.B

IT
2200
1200
1200

150
2800 C

8200
650
9
PLOT LIMIT ICK. RAFT
500mm TH
PC27
PC27 -4.500 SSL
5
S5105 General Notes:
2800 2.C
5
1 1. DO NOT SCALE FROM THIS DRAWING.
S5105
SP0999b
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
2200 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
1200 BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

750
1500 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
2800

900
8

8200
AT SITE.

PC27 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
PC26 AND RELEVANT SECTIONS OF THE SPECIFICATION.

2800 2
2200 2.D
2.05 2.06 2.07 S5106
1200
0x600
RAMP 2
6 OPENING 80 SSL
VEL -1 .300
AT LE

1150
S5107
8200 12300

2100

1150
1150
PC27 PC27 1150
7 1500 50

750
2800 PC27 TRENCH

900

8200
650 PC27

750
1000X300X300 1150
0mm
1
600X600X30
PC27 PC27 PC20 150 RAIN PIT S5107
D
500mm THICK. RAFT PC28

2 0
TRENCH PC27
-4.500 SSL 600X600X40 4000X300X300
PIT

2300
S5106 mm DRAIN
5 1150 2.E
S5107 1600

750
1150

1150

1150

150 300
PC27 PC27 2950 4450 PC27

900
6 4 PC27 PC27
750 750 PC1
S5105 1450

900
TRENCH

750

8200
PC1
3650X300X300 PC3
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

900
750

2900
PC7 0
AUTHORITY APPROVAL 17.08.2017 NS
1700

6200
Purpose of Issue Rev. Date Appoved
600mm 1450
750 900 ST2-02 600X600X IT Client:
4765 725
200 DRAIN P 2.F
2.E' 825 -4.500 SSL 2
100

100

2400

900
1500

S5106
200

750
5

900
PC26
PC3
-6.300 SSL MEYDAN L.L.C
PC5 PC19 P.O. Box 9305, Dubai , UAE.
PC3 T: +9714 3270000 F: +9714 3270007
2600

8200
PC19 PC23 PC1
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
9500

2400 PC18 1700


2500

750 4610 875 750

750 1250 850 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
1150 2.G www.ae-7.com
2400 Hassanicor Building, 6th Floor, Al Barsha 1
2250

PO Box 54115 Dubai, UAE


9 3250 P: +971 4 3997758 F: +971 4 3997759
4 PC8

750
200

2.F' S5108

750
300 1750 150

PC3 Sub-Consultant:
PC3 850 PC27
2050
2200

900 4610 PC19

2500
PC5 1150

750
PC12 PC25
150

8200
2.G'

200
PC24 PC1

1500
PC1
750

PC3
ICK. RAFT PC27
SUMP PIT 500mm TH

2240
2000x2000x2500 1450
-4.500 SSL Project Name:
2.H
50 1750
DUBAI WATER CANAL

1210
9500

3 610
500mm THICK. RAFT 3275 PC31 SAFA A

520
975
750 4785 700 PC29
-4.500 SSL 1000 PC3

1350
900 DUBAI-UAE
PC1
3275 PLOT LIMIT

1800
PC30
150 725

1 Project Description:
S5106
PC31 MIXED USE DEVELOPMENT
300 645

2.H'
100

PC5 PC6 PC24


50

PC1
700

975 700

PC3 750
775
PC27 (RETAIL & RESIDENTIAL)
2455

1800
1655

750
750
PC27
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
1800

PC27 PC27

Drawing Title:
1800

1
1800

1 S5106 LEGEND:
S5106
PLOT LIMIT R.C. COLUMN
BASEMENT 01 LEVEL - FRAMING &
R.C. WALL PILE CAPS PLAN - PART C
PLANTED COLUMN / WALL

NOTE: Scale Drawn Checked Approved Size


1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS AA MA NS
1 2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS 1 : 150 A1
3. FOR FAOUNDATION DETAILS REFER TO DWG. 00-S5101 TO DWG. 00-S5109 08.06.2017 24.08.2017 24.08.2017
BASEMENT 01 LEVEL - FRAMING & PILE CAPS PLAN - PART C 4. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO DWG. 00-S5508
1 SCALE 1 : 150
5. FOR RAMP DETAILS REFER TO DWG. 00-S5601 TO DWG. 00-S5603
6. FOR WATER TANK DETAILS REFER TO DWG. 00-S5901
Drawing Number Rev.
7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
8. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
14011603-01-00-SP0999c 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

N
11

Q
N
10 KEY PLAN

T
L IMI
OT
PL

1.D 01

0
1.C 950

820
9 1.B

0
0 02
220

0
1.A 950
General Notes:

820
0
1.01
IT 1. DO NOT SCALE FROM THIS DRAWING.
T LIM
P LO 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

820
BY THE ENGINEER.

0
1.02
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
PLOT LIMIT

820
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

0
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
1.03 AND RELEVANT SECTIONS OF THE SPECIFICATION.

820
2.12

0
1.04 2.10 2.11
9500
2.08 2.09 2200
9500 2.A
2800

820

8200
SC0
0

1
7

999
1.05

b
2.B

820

SC0
1 a
0

999

8200
1.06

1 1 2.C

820
SC0999c SC0999b

0
1.07

8200
6
2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.D

8200 8200 8200 8200 8200 12300


100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

8200
AUTHORITY APPROVAL 0 17.08.2017 NS
PLOT LIMIT Purpose of Issue Rev. Date Appoved
2.E
Client:

8200
1.08
5
2.E'
2.F MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
8200

T: +9714 3270000 F: +9714 3270007


E: info@dubairacingclub.com W: www.dubairacingclub.com

8200
9500

Principal Consultant:
1.09

2.G

2.F'
2200
11200

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

8200
2.G' www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
2.H P: +971 4 3997758 F: +971 4 3997759
4
9500

1.10 Sub-Consultant:

PLOT LIMIT
8200

2.H'

1.11

PLOT LIMIT Project Name:


2200 14500 5600
3
DUBAI WATER CANAL
1B' 1C' 03 04
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

BASEMENT 01 LEVEL - COLUMNS &


WALLS SETTING OUT - OVERALL
LEGEND:
PLAN
R.C. COLUMN
Scale Drawn Checked Approved Size
R.C. WALL AA MA NS
1 1 : 350 A1
PLANTED COLUMN / WALL
26.05.2016 24.08.2017 24.08.2017

BASEMENT 01 LEVEL- COLUMNS & WALLS SETTING OUT PLAN - OVERALL NOTE: Drawing Number Rev.
1 1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS
14011603-01-00-SC0999
SCALE 1 : 350 2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

PLOT LIMIT DUBAI MUNICIPALITY STAMP:

860

N
11
1.D 750 01

Q
350
350

295
0
220

0
0
950

350
350

820
1.C

0
0
630

290
1.B N
KEY PLAN

0
10 0 02 A
220
350

350 0
50

250
5
5
942

400
0
950
0 950

1.A

820
106

0
0
850
0
10305 1.01
9

PLOT LIMIT 300

600
250
175 General Notes:
750

600
400
1. DO NOT SCALE FROM THIS DRAWING.
14

820
1C

0
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
5
389
BY THE ENGINEER.
1.02
300
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
425
3700
165

925
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

600
8 AT SITE.

600
10775
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
14
1C ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
491

AND RELEVANT SECTIONS OF THE SPECIFICATION.


0

150
5
532 0
190

150
490

820
1
300 1W
0

0
600
600

14 1.03
600

1C

150
0
120

150
7
250 1C
1
0
165 0
150
120 150

150
2 0
1C 190

150

820
2
1W

0
__
___
_1__ 1.04
01-S5201

200
0
120

200
6 700 1C
3
150

1CW1 0
120
200

150
4 0
1C 190

150
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

820
2
1W

0
AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
200 1.05 Client:
0
120
200

SC0
1
5
1C

999
b
5
200

0
120 MEYDAN L.L.C
200

150
0 P.O. Box 9305, Dubai , UAE.
5
190

150
1C T: +9714 3270000 F: +9714 3270007
2 E: info@dubairacingclub.com W: www.dubairacingclub.com

820
1W

0
Principal Consultant:
200

0 1.06
120
300
200

200

8 0
1C 120
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
200

www.ae-7.com
5 Hassanicor Building, 6th Floor, Al Barsha 1
1C PO Box 54115 Dubai, UAE
200

0
4 120 P: +971 4 3997758 F: +971 4 3997759
200

150
6 0 Sub-Consultant:
1C 190

150
2

820
1W

0
200

0
120
300
200

1.07
200

6 0
1C 120
200

5 Project Name:
1C
125

0
120
700 DUBAI WATER CANAL
175

3 10
1C
SAFA A
DUBAI-UAE

750
175

0
120 Project Description:
300
175

11
1C MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

BASEMENT 01 LEVEL - COLUMNS &


350

LEGEND:
WALLS SETTING OUT - PART A
R.C. COLUMN
Scale Drawn Checked Approved Size
R.C. WALL
AA MA NS
1 PLANTED COLUMN / WALL 1 : 150 A1
26.05.2016 24.08.2017 24.08.2017
BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART A NOTE:
1 SCALE 1 : 150 1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS
Drawing Number Rev.
2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS
14011603-01-00-SC0999a 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


1.D 1.05

N
11

SC0
1 a
999

Q
820
0
1.06

N
10 1 KEY PLAN
SC0999c

820
0
0 B
950
1.07
1.C

150
0
190

150
1.B 0
9 220 2
1W 2.01 2.02 2.03 2.04 2.05

750 8200 8200 8200 8200


950
0 General Notes:

200
0
120

200
1. DO NOT SCALE FROM THIS DRAWING.
5
1.A 1C
150

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


0
120 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
150

1C
10 __
___
_3__ BY THE ENGINEER.

01-S5202 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
0
506
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

750
W2 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
175

566
0 1C
120 AND RELEVANT SECTIONS OF THE SPECIFICATION.

5
300
175

350
150

11 0
120


1C
200

1.7
12
7
1C

148.
125

4080
120
125

23°
9

2125
1C

1.08
1W3

350 1350
7
175

0
120 200 200
175

300 150 50 300 2.E'


11 200 200 200 200
1C

1200

1200

1200
350 6750 200 150 300 150 150

2400
8200

1200

1200
1200
2C23 2W1 2C3 2C6 2C6

1900
6500
50 350
1C16
1200

1C11
__
___
_1__
782

3050
2CW-1
0

02-S5201
1500

9500
1900 1950
150 150

175 125

6 1.09

350 1000
1000

1W4 1W5

00
07
100
500

250 150 200 200 200 200 200 200


300 300 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
12
1C 2C6

1200

1200

1200

1200

1200
AUTHORITY APPROVAL 0 17.08.2017 NS
__
___
_4__ 150 50 2C2 2C5 2C6
2.F' Purpose of Issue Rev. Date Appoved
200 200

1200
01-S5202

2200
1C16 2C23 Client:
11200

150 250 200 200 200 200 200 200 200 200
1CW3
2200
300 300 2.G'
150 150

1200

1200

1200

1200

1200
150 50 2C4 2C4 2C2 2C2 2C2
5
1200

1200

700
1C16
MEYDAN L.L.C
1C16 2C23 P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
175 375
2600

E: info@dubairacingclub.com W: www.dubairacingclub.com
2750

1900 5700 1900


Principal Consultant:
50 1150

1C13 150 150


150 150
150 150

9500
1050 150

1.10
1W5 1W6
1C16
3600

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


300 300 150 250
200 200 175 175 www.ae-7.com
175 175 175 175 Hassanicor Building, 6th Floor, Al Barsha 1
150 50
PO Box 54115 Dubai, UAE
1900

1600

1600
2C10

1400

1400
2W8 2C12 2C12 P: +971 4 3997758 F: +971 4 3997759
4
8200

2W9
1200

2.H' Sub-Consultant:
1C16 2C23

150 150

50 1900 5700 1900


600 600

1.11
300

300

1W7 1W4 1C15

Project Name:
1800

3
DUBAI WATER CANAL
SAFA A
PLOT LIMIT
DUBAI-UAE

Project Description:
2200 14500 5600
MIXED USE DEVELOPMENT
1B' 1C' 03 04 (RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

BASEMENT 01 LEVEL - COLUMNS &


WALLS SETTING OUT - PART B
LEGEND:
R.C. COLUMN
Scale Drawn Checked Approved Size
R.C. WALL AA MA NS
1 1 : 150 A1
PLANTED COLUMN / WALL 26.05.2016 24.08.2017 24.08.2017
BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART B
1 NOTE: Drawing Number Rev.
SCALE 1 : 150 1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS
2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS 14011603-01-00-SC0999b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


2.12

2.11

N
2.10
11
2.09 9500 2.A
2.08

Q
2200
9500
2800

8200
N
10 KEY PLAN

PLOT LIM
2.B

7550

IT
100 300

650
125
1200

8200
150 350

1075
PLOT LIMIT 2C2 C
2C17
9

2.C
1 General Notes:
SC0999b
1. DO NOT SCALE FROM THIS DRAWING.

1200 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

250 250
BY THE ENGINEER.
1200

8200
250 250
2C16 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 2C16 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

2.D
2.05 2.06 2.07
6950

200
1400

200
200
8200 12300
1200 65 2C18 2C12

50

150
200

350 30
1200 2C18

8200
1205

490
250 250

150
7 500 350
4500

90
2C16 4650

415

300
350 2150

350
75
00

4210
2.E
2015

7500
871

175
0 1400
11350

00

205
77

175
1200 1200 2C12

95
175 175
2C2

200
300

6 5470

8200
2C15

200 200
2C5

1200

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


750
AUTHORITY APPROVAL 0 17.08.2017 NS
2.F Purpose of Issue Rev. Date Appoved
__
___
_1__
200 200 125 175
2.E'
275 125 Client:
1200

1200

150 150 02-S5202


1400

175 175
1200
2900

2C13
1200

2C6 2W2 2W3 1400 2C12


1900

125
5 2C14
MEYDAN L.L.C

175
2750

8200
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
9500

E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
2800

200 200
150 150 125 175
2.G
200 200 2W5 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
1900

50 250
1900

1900

2C6 2W4 www.ae-7.com


1200

2W6 1400 Hassanicor Building, 6th Floor, Al Barsha 1

200
2.F' 3950 PO Box 54115 Dubai, UAE
400

1900
2W7 P: +971 4 3997758 F: +971 4 3997759
4 250 50 2C9

200
2200

1200 100
Sub-Consultant:
200 200 200 200 200 200 2C2
2W12

8200
2.G'
1900
1200

1200

1200

2C2 2C3 2C7

2.H
Project Name:
9500

1400
60 340
DUBAI WATER CANAL

450
3 3825
400 2C8 2C11
SAFA A
1200
150 150 125 225 250 50
175 175 2C2
1200

PLOT LIMIT
DUBAI-UAE
2W1
1900
2000

2000

2W10 2W11
1600

2W9
2.H' Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
1800

PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

PLOT LIMIT
BASEMENT 01 LEVEL - COLUMNS &
LEGEND:
WALLS SETTING OUT - PART C
R.C. COLUMN
Scale Drawn Checked Approved Size
R.C. WALL
AA MA NS
1 PLANTED COLUMN / WALL 1 : 150 A1
BASEMENT 01 LEVEL - COLUMNS & WALLS SETTING OUT PLAN - PART C 26.05.2016 24.08.2017 24.08.2017

1 SCALE 1 : 150
NOTE:
1. FOR COLUMNS & WALLS SCHEDULES REFER TO EACH BUIDLING SHEETS
Drawing Number Rev.
2. FOR CORE WALL DETAILS REFER TO EACH BUILDING SHEETS
14011603-01-00-SC0999c 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

N
11

Q
T
L IMI
OT
PL

1.D
N
10 01 KEY PLAN
0
1.C 950

820
0
1.B 0 02
220

0
1.A 950

820
0
1.01
IT
LIM
OT
PL
9

820
0
1.02

General Notes:
PLOT LIMIT

820
0
1. DO NOT SCALE FROM THIS DRAWING.
1.03
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

820
2.12

0
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
1.04 2.10 2.11 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 9500
2.08 2.09 2200 AT SITE.
9500 2.A
2800 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

820
AND RELEVANT SECTIONS OF THE SPECIFICATION.

8200
0

SF1
1
1.05

000
b
2.B

820

SF1
0

1 a

8200
000
1.06

1 1 2.C
7 SF1000c SF1000b

820
0
1.07

8200
2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.D

8200 8200 8200 8200 8200 12300

8200
50mm EXPANSION JOINT
2.E
6

8200
1.08

2.F 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


2.E' 0
AUTHORITY APPROVAL 17.08.2017 NS
8200

Purpose of Issue Rev. Date Appoved

8200
9500

Client:
1.09

2.G

2.F'
5
2200
11200

MEYDAN L.L.C

8200
2.G'
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
2.H
9500

1.10 Principal Consultant:

PLOT LIMIT
8200

2.H'
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
1.11 Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
PLOT LIMIT Sub-Consultant:

2200 14500 5600

1B' 1C' 03 04

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:
LEGEND:
R.C COLUMN CONTINUE
MIXED USE DEVELOPMENT
R.C WALL CONTINUE (RETAIL & RESIDENTIAL)
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL PLOT 01 / 3435338
UPSTAND
2
SLAB OPENING 400 C.I.P
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
200 C.I.P 450 C.I.P
500 C.I.P Drawing Title:
250 C.I.P
550 C.I.P
300 C.I.P
350 C.I.P
600 C.I.P
GROUND LEVEL - FRAMING PLAN -
P.C. PLANTED COLUMN P.T POST TENSION
P.W. PLANTED WALL
C.I.P. CAST IN PLACE
D.P DROP PANEL OVERALL
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202
2. FOR SLAB REINFORCMENT SCHEDULE REFER TO DWG. 00-S6301 Scale Drawn Checked Approved Size
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508 AA MA NS
1 4. FOR P.S. & D.P. REFER TO DWG. 00-S5301 1 : 350 A1
5. STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, ETC…) SHOWN IN 26.05.2016 24.08.2017 24.08.2017
DRAWINGS FOR INDICATIVE ONLY TO BE DESIGNED AND VERIFIED BY THE

GROUND LEVEL - FRAMING PLAN - OVERALL STRUCTURAL STEEL SUPPLIER AND SUBMITTED FOR THE ENGINEER APPROVAL.
6. FOR THE RINFORCEMENT AROUND SLAB OPENING REFER TO DWG. 00-S5302
Drawing Number Rev.
1 7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
14011603-01-00-SF1000
SCALE 1 : 350 8. FOR RAMP DETALS REFER TO DWG. 00-S5601 TO 00-S5603
9. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

PLOT LIMIT
DUBAI MUNICIPALITY STAMP:

N
11 1.D 01

Q
0
950

820
1.C

0
1.B
0
220 02 N
10 KEY PLAN A

1
MP
0 RA 750
950

1.A
1

820
0
S5602

200
200

1.01
0
260
9
0
225
350

0
950
mm

0
200 200
610
. TH

PLOT LIMIT

200
0
ICK
200

10

0
+0.

General Notes:
C.I
800

400
170

P.S
S5303
.P
SS

mm
SL
0

.1
7

820
L P

D.P
AB

. TH
200

600
220

0
+0.

1. DO NOT SCALE FROM THIS DRAWING.


200

ICK
S5303
800

LAN

950

C.I
S

+0.
5 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
TE

.P
222
250

SL

735

400
R

NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

SL
7
0

220 1.02

AB
BY THE ENGINEER.

SS
200

L
200
S5303
150

0
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
R MANHOLE
02

TE SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

125
8 AN

P.S
00

46 PL 600X600XDEPTH AT SITE.
RB

.1
0

PL
1-G 343

AN
0
200
950

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

D.P
TE

600
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

R
AND RELEVANT SECTIONS OF THE SPECIFICATION.
0
200

820
150
0
120
200

0
600
700
0
P.S
D.P

.1
600

1 1.03
RB
1-G

1-G
29
RB
740

RB
1-G

6
300
R
TE

mm
7 AN
7 PL

. TH

350
2
RB

ICK
S5303 5
219

mm
1-G

+0.

C.I

. TH
.P
600

ICK
SL

-0.1
SS

AB

820
C.I
00
1

L
RB

0
.P
SS
1-G

SL
5

L
RB

AB
1-G
1-L

1.04
B1

1-G
30
RB

RB
1-G
LIF

7
RB 10
1-L
T

0 1-G
181
B1

S5303
575

350
300
6 700 3
RB

mm
1-G

mm
1-G
ST 00

300

. TH
RB

. TH
1-0
2
47

ICK
ICK

-0.1
2

+0.

C.I
00
C.I

820
100

.P
.P

SS

0
SL
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
SS

SL

AB
AB
L
AUTHORITY APPROVAL 0 17.08.2017 NS
15 1.05 Purpose of Issue Rev. Date Appoved

1-G
S5304 1
B1 31 Client:
1-L

RB
RB
1-G

7
P.S

48
RB
.2

SF1
1-G

1
350

000
b
mm
5
P.S

. TH
P.C. MEYDAN L.L.C
.2
1-G

ICK
350

RB

P.O. Box 9305, Dubai , UAE.


mm

C.I

820
-0.4
23

T: +9714 3270000 F: +9714 3270007

.P
. TH

0
00

SL
E: info@dubairacingclub.com W: www.dubairacingclub.com
ICK

SS
1-G

AB
-0.1

L
Principal Consultant:
C.I

RB
00

.P

8
P.C.
SS

SL

18 1.06
RB
L

AB

1-G
30

1-G
RB
33
__
___
_1__ 1-G
RB
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

350
S5308 www.ae-7.com

mm
17 Hassanicor Building, 6th Floor, Al Barsha 1
RB

. TH
P.C. 1-G 500 PO Box 54115 Dubai, UAE
1-G

ICK
-0.4
P: +971 4 3997758 F: +971 4 3997759
4 600
RB

160

C.I
00
350

Sub-Consultant:
24

.P
SS
0

820
mm

SL
L
10

0
AB
. TH

1-G

16 P.C.
RB
RB
ICK

1-G
S5303
-0.1

19
C.I

376
300
00

.P

0
mm
SS

SL
L

AB

. TH

1.07

1-G
P.C. 30
ICK

RB
RB
350
-0.2

1-G

8
C.I

34
mm
00

RB
.P

1-G
SS

. TH
SL
L

AB

P.C. 0 Project Name:


ICK

290
-0.
1-G

800

C.I

500 750
RB

.P

DUBAI WATER CANAL


SS

500
SL
24

112
L

TRENCH
P.S

3
AB

110
350

0
350

.3

700 2000X300X300 SAFA A


0
mm

mm

1-G
. TH

. TH

RB

LEGEND:
ICK

19
-0.2

DUBAI-UAE
ICK
-0.4

C.I

00

R.C COLUMN CONTINUE


00

415

20
C.I

1-G
.P

RB
SS
SS

.P

1-G
RB
SL

SL

TRENCH
L

R.C WALL CONTINUE


AB

9
AB

30 Project Description:
2000X300X300 RB R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
32 1-G
RB MIXED USE DEVELOPMENT
100

1-G
1-G

0 R.C PLANTED COLUMN / WALL @ FLOOR LEVEL


325
0
RB

P.C. 10
(RETAIL & RESIDENTIAL)
21

UPSTAND
1-G

0 400 C.I.P
525
S5303
TRENCH
460
RB

SLAB OPENING PLOT 01 / 3435338


24

1750X300X300 450 C.I.P


P.S

0
117 200 C.I.P 500 C.I.P BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
.3

2 300
0 250 C.I.P
325 550 C.I.P
295

600 Drawing Title:


300 C.I.P
0

300 600 C.I.P


371

350 C.I.P
300
0

1-G
RB
22 P.C. PLANTED COLUMN
P.W. PLANTED WALL
P.T
D.P
POST TENSION
DROP PANEL GROUND LEVEL - FRAMING PLAN -
PART A
C.I.P. CAST IN PLACE
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S602 & 02-S6201 TO 02-S6202
2. FOR SLAB REINFORCMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR P.S. & D.P. REFER TO DWG. 00-S5301 Scale Drawn Checked Approved Size
5. STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, ETC…) SHOWN AA NS
IN DRAWINGS FOR INDICATIVE ONLY TO BE DESIGNED AND VERIFIED BY THE
MA
1 STRUCTURAL STEEL SUPPLIER AND SUBMITTED FOR THE ENGINEER APPROVAL.
1 : 150 A1
6. FOR THE RINFORCEMENT AROUND SLAB OPENING REFER TO DWG. 00-S5302 26.05.2016 24.08.2017 24.08.2017
7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
GROUND LEVEL - FRAMING PLAN - PART A 8. FOR RAMP DETALS REFER TO DWG. 00-S5601 TO 00-S5603 Drawing Number Rev.
1 9. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
14011603-01-00-SF1000a
SCALE 1 : 150 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

1.D
1.04
1.05 DUBAI MUNICIPALITY STAMP:

N
11

350
0
950

mm
. TH
ICK

Q
1.C

C.I
-0.4

.P
00
1.B

SL
SS
1-G

AB
0

L
220

RB
8
18 1.06
RB
1-G

820
__
___
_1__ 30

0
RB

SF1
1 a
1-G

000
S5308
0

350
950 N
KEY PLAN

mm
10 17
RB

. TH
1.A 1-G 500

ICK
-0.4
600

160

C.I
00
1

.P
SS
0

SL
L
10 SF1000c

AB
1-G
16
RB

RB
1-G
S5303

19

376
B

0
1.07

820
1-G
30

0
RB
RB

350
1-G

8
mm

350
. TH

mm
0

ICK
290

-0.

. TH
1-G

800

C.I
9

-0.4

ICK
500 750
RB

.P
SS

500

00
SL

C.I
24

112
L
TRENCH
P.S

SS
AB

.P
110

L
350

SL
.3

700 2000X300X300

0
2.01 2.02 2.03 2.04 2.05

AB
mm

1-G
. TH

RB
19 General Notes:
-0.2

ICK
00

415
20
C.I

1-G
RB 8200 8200 8200 8200
SS

.P

0
1-G

RB
1. DO NOT SCALE FROM THIS DRAWING.
L

SL

TRENCH

9
AB

2000X300X300 30
RB 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
1-G NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

100
1-G
0
325
BY THE ENGINEER.

0
RB
10

21
1-G

0 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


525
S5303
TRENCH

460
RB

350mm. THICK C.I.P SLAB SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
24

1750X300X300 10 AT SITE.
P.S

0
117 -0.400 SSL
.3

300 S5303 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
PLOT LIMIT
0 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
325

295
600 AND RELEVANT SECTIONS OF THE SPECIFICATION.

0
300 50mm. EXPANSION JOINT

750
371

300x450x600

300
0

400 22 OPENING AT +1.80LEVEL


200 RB
1-G
600

32 1150 820 1180


RB
1-G 350mm. THICK C.I.P SLAB
150

1445 505

1-GRB10
350mm. THICK C.I.P SLAB -0.400 SSL
1-G
P.C

350mm. THICK C.I.P SLAB


RB

1-GRB45

2-GRB17

2-GRB21
P.S

-0.400 SSL
.

7
25

.4
350

1.08 8 -0.400 SSL

1-GRB11
mm

2-GRB24
1605
S5303
. TH

300
ICK
-0.4

mm

3750 200
. TH
00

C.I

1-GRB38
.P
SS

ICK

945
-0.2
SL

4 2.E'
L

700 200
AB

C.I

4075
00

1100 1225 1100

1425
.P

1-GRB39
S5303
SS

32
SL

RB PLANTER
L

AB

1-G 350mm. THICK C.I.P SLAB


1-GRB11
2 -1.500 SSL

2-LB1
ST2-01 2-GRB8
S5303 2-GRB4 2-GRB5 200 2-GRB7
750 -0.400 SSL
1-GRB38
P.C

350mm. THICK C.I.P SLAB


7450
1-GR
.

-0.400 SSL
B26

6 300mm. THICK C.I.P SLAB

1745

1500
3850 150

9500
TRENCH
1-GRB12

2-GRB16
1.09 -0.200 SSL 1500X300X300
625

1-GRB44

2-GRB26
175 1595 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
LIFT
AUTHORITY APPROVAL 0 17.08.2017 NS
675 200 1465 TRENCH
1-LB6

2540
750 1000
ESCALATOR 1500X300X300 Purpose of Issue Date Appoved

750 300
Rev.
6285

1-LB12
Client:

210
TYPICAL STEEL COLUMN 2.F'
2-GRB19 P.S.9 P.S.6
350

1-G

2-GRB18
SUPPORTING PLAZA CANOPY 400 3200 250

2200
mm

RB

REFER TO DETAIL 17 SHEET S5305

2-GRB27
26
. TH

1-GRB43
-0.4

ST1-01
ICK

1-LB16

200 2.G'
00

5
MEYDAN L.L.C
C.I
SS

.P
L

SL

2515

2-GRB19 300mm. THICK C.I.P SLAB P.O. Box 9305, Dubai , UAE.
AB

P.S.2 P.S.2 P.S.5 T: +9714 3270000 F: +9714 3270007


1-GR

E: info@dubairacingclub.com W: www.dubairacingclub.com
-0.200 SSL
B13

350mm. THICK C.I.P SLAB Principal Consultant:


1-GRB37

1-GRB40

2-GRB17
1650

1-GRB27 -0.400 SSL


9

9500
1.10 S5303
2-GRB26
1-GRB42

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
2650

Hassanicor Building, 6th Floor, Al Barsha 1


350mm. THICK C.I.P SLAB 350mm. THICK C.I.P SLAB PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 -0.400 SSL -0.400 SSL
300mm. THICK C.I.P SLAB 2-GRB1 2-GRB2 2-GRB2 2-GRB2 Sub-Consultant:
1-GRB28

1-GRB14

1-GRB36

-0.200 SSL 1-GRB38


P.W. 2.H'

4 250mm. THICK C.I.P SLAB


350mm. THICK C.I.P SLAB P.C
-1.500 SSL
3380

S5303
1-GRB39

1-GRB41

2-GRB25

-0.400 SSL
P.C.
PLANTER
1.11
1-GRB35

Project Name:
1-GRB15 935

DUBAI WATER CANAL

1800
3
1800

SAFA A
1800

PLOT LIMIT

DUBAI-UAE
LEGEND:
PLOT LIMIT
R.C COLUMN CONTINUE

R.C WALL CONTINUE Project Description:


R.C COLUMN / WALL STOPPING @ FLOOR LEVEL MIXED USE DEVELOPMENT
2200 14500 5600 R.C PLANTED COLUMN / WALL @ FLOOR LEVEL
(RETAIL & RESIDENTIAL)
UPSTAND 400 C.I.P
1B' 1C' 03 04
PLOT 01 / 3435338
SLAB OPENING 450 C.I.P
2 200 C.I.P
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
500 C.I.P
250 C.I.P 550 C.I.P Drawing Title:
300 C.I.P
600 C.I.P
350 C.I.P
P.C. PLANTED COLUMN P.T POST TENSION
GROUND LEVEL - FRAMING PLAN -
P.W. PLANTED WALL
C.I.P. CAST IN PLACE
D.P DROP PANEL
PART B
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S602 & 02-S6201 TO 02-S6202
2. FOR SLAB REINFORCMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508 Scale Drawn Checked Approved Size
4. FOR P.S. & D.P. REFER TO DWG. 00-S5301 AA MA NS
5. STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, ETC…) SHOWN 1 : 150 A1
1 IN DRAWINGS FOR INDICATIVE ONLY TO BE DESIGNED AND VERIFIED BY THE 26.05.2016 24.08.2017 24.08.2017
STRUCTURAL STEEL SUPPLIER AND SUBMITTED FOR THE ENGINEER APPROVAL.
6. FOR THE RINFORCEMENT AROUND SLAB OPENING REFER TO DWG. 00-S5302
GROUND LEVEL - FRAMING PLAN - PART B 7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS Drawing Number Rev.
1 SCALE 1 : 150
8. FOR RAMP DETALS REFER TO DWG. 00-S5601 TO 00-S5603
9. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308 14011603-01-00-SF1000b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

2.12 DUBAI MUNICIPALITY STAMP:


2.11
2.10
9500

N
11 2.09
2.08 2200
1500 2.A
9500 750 2200
2650

Q
850 650
2800

775
600 900 2-GB31 PC3

725
2-GB31 PC24

425
3350

8200
2075
2700
PC8

2-GB31
1500 P.C.
200 P.C. N
10 285 1250
200 1870 2150 KEY PLAN
LAB
ICK C.I.P S 2-GB31

1500
300mm. TH ICK C.I.P S
LAB

PLOT LIM
350mm. TH

2-GB32
200 1500
70 800 2.B

200
200 10 -0.100 SSL 1000 1950
1600

IT
750 750
1

2825
5

2-GB31

750 750
2-GB31
S5303
2-GB31

450 50
S5303 PC3
P.C. 3350
2-GB31

200 1795
PLANTER PC2

2-GB31
200
3315 PC3 1500

8200
85 200
2950

200
PLOT LIMIT C

1500
9

200 1490
PLANTER P.C. PC3
2-GB28

3300
200
5 2.C
1
SF1000b
S5303 ST2-03
__
___
_2__ General Notes:

3500
RAMP 2 PC22 200 S5308
1. DO NOT SCALE FROM THIS DRAWING.

1125
LAB
ICK C.I.P S
300mm. TH 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
200
10 1870

200 1490
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
80 120 16 2150 BY THE ENGINEER.

1105

8200
TRENCH 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

200
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 1750X300X300
200 230 AT SITE.
1900

200 1565
200 205 1700
LAB
ICK C.I.P S 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
PLANTER 300mm. TH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
-0.200 SSL TRENCH AND RELEVANT SECTIONS OF THE SPECIFICATION.

200
1800X150X150 2.D
2.05 2.06 2.07 5 5770

3500
S5303

2040
LAB
8200 12300 ICK C.I.P S
300mm. TH
200
1900

200 1535
200 1290 200
750

8200
7

200 400

200 1565
TRENCH
350mm. THICK C.I.P SLAB 800 200 1850X300X300
200 935 1335

200
-0.400 SSL 7.709°

2-GRB1
7.709°
2.E

3500
200

L 3
PLANTER -0.400 SS

200 1535
S5303
LAB
ICK C.I.P S
2-GRB14 IN
PLANTER
200

3100

350mm. TH

150
LAB 6 200 2-GRB11
ICK C.I.P S 2135 P.S.6
350mm. TH 1340

200 400
6

8200
LAB
ICK C.I.P S
S5303
200 350
3100

L
V

-0.400 SS 300mm. TH
200 500

2-GRB15
6

2-GRB15
8550
2-GRB21

2400
S5303 200 LAB 2-GRB12
-0.200 SSL

2-GRB22
ICK C.I.P S

2-GRB2
350mm. TH
200

200950 2150
3050
7.709°

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


550

6550
-0.400 SSL
2-GRB23

200 2-GRB13
2-GRB14 IN

AUTHORITY APPROVAL 0 17.08.2017 NS


7.709°

ST2-02 3200
300 2.F
2600 1525 200 3150 Purpose of Issue Rev. Date Appoved
1700
2.E'

300
1200 200

500
V

4075 Client:
1425

2-GRB20 2-GRB10
2-GRB9

2-GB30
2-GRB6
5 P.S.8
LIFT MEYDAN L.L.C

8200
LIFT
LAB P.O. Box 9305, Dubai , UAE.
2-LB3 ICK C.I.P S
2-GRB23

2-LB3 350mm. TH T: +9714 3270000 F: +9714 3270007


E: info@dubairacingclub.com W: www.dubairacingclub.com
2-LB2 -0.400 SSL

2-GRB2
300mm. THICK C.I.P SLAB 450mm. THICK C.I.P SLAB Principal Consultant:
650x1000
-0.200 SSL OPENING 45 SSL
-0.200 SSL 175 2325 LEVEL +4.5 750
AT
2.G

600 400 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
260 865
200 925

www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
2.F' 500 1000 PO Box 54115 Dubai, UAE
P.S.9 P.S.6 P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

8200
2.G'
P.S.7

2-GRB1
P.S.5

LAB
ICK C.I.P S
300mm. TH
2-GRB29

2.H
-0.200 SSL Project Name:
2-GRB1
3
DUBAI WATER CANAL
2-GRB2 -0.200 SSL
SAFA A
2-GRB2
2-GRB2 2-GRB3 2-GRB2 PLOT LIMIT LEGEND: DUBAI-UAE
R.C COLUMN CONTINUE
1800

2.H' R.C WALL CONTINUE Project Description:


R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
350mm. THICK C.I.P SLAB ICK C.I.P S
LAB MIXED USE DEVELOPMENT
P.C 350mm. TH R.C PLANTED COLUMN / WALL @ FLOOR LEVEL

-0.400 SSL UPSTAND 400 C.I.P (RETAIL & RESIDENTIAL)


PLOT 01 / 3435338
1800

SLAB OPENING 450 C.I.P


2 200 C.I.P 500 C.I.P BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
250 C.I.P 550 C.I.P
Drawing Title:
300 C.I.P
600 C.I.P
PLOT LIMIT 350 C.I.P
P.C. PLANTED COLUMN
P.W. PLANTED WALL
P.T
D.P
POST TENSION
DROP PANEL
GROUND LEVEL - FRAMING PLAN -
C.I.P. CAST IN PLACE
NOTE:
PART C
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S602 & 02-S6201 TO 02-S6202
2. FOR SLAB REINFORCMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR P.S. & D.P. REFER TO DWG. 00-S5301 Scale Drawn Checked Approved Size
5. STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, ETC…) SHOWN AA MA NS
1 IN DRAWINGS FOR INDICATIVE ONLY TO BE DESIGNED AND VERIFIED BY THE 1 : 150 A1
STRUCTURAL STEEL SUPPLIER AND SUBMITTED FOR THE ENGINEER APPROVAL. 26.05.2016 24.08.2017 24.08.2017
6. FOR THE RINFORCEMENT AROUND SLAB OPENING REFER TO DWG. 00-S5302
7. FOR EARTH PITS LOCATION REFER TO ELECTRICAL DRAWINGS
GROUND LEVEL - FRAMING PLAN - PART C 8. FOR RAMP DETALS REFER TO DWG. 00-S5601 TO 00-S5603
Drawing Number Rev.
1 SCALE 1 : 150
9. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
14011603-01-00-SF1000c 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

N
11

Q
T
L IMI
OT
PL

1.D 01
N
10 KEY PLAN
0
1.C 950

820
0
1.B 0 02
220

0
1.A 950

820
0
1.01
T
L IMI
OT
PL
9

820
0
1.02

PLOT LIMIT
General Notes:

820
0
1.03 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

820
2.12

0
1.04 2.10 2.11 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
2.09 9500 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 2.08 2200 2.A AT SITE.
9500
2800
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

820

8200
SRB
AND RELEVANT SECTIONS OF THE SPECIFICATION.

1
1.05

099
9b
2.B

820

SRB
1 9a
0

099

8200
1.06

1 1 2.C
7

820
SRB0999c SRB0999b

0
1.07

8200
2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.D

8200 8200 8200 8200 8200 12300

8200
PLOT LIMIT
2.E

8200
1.08

2.F 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


2.E'
AUTHORITY APPROVAL 0 17.08.2017 NS
8200

Purpose of Issue Rev. Date Appoved

8200
9500

1.09
Client:
2.G

2.F'
2200
11200

5
MEYDAN L.L.C

8200
2.G'
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
2.H E: info@dubairacingclub.com W: www.dubairacingclub.com
9500

1.10
Principal Consultant:

PLOT LIMIT
8200

2.H'

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


1.11 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
PLOT LIMIT Sub-Consultant:
2200 14500 5600

1B' 1C' 03 04

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 LEGEND: BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
R.C COLUMN CONTINUE Drawing Title:
R.C WALL CONTINUE
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL BASEMENT 01 LEVEL - BOTTOM
UPSTAND
SLAB OPENING REINFORCEMENT PLAN - OVERALL
P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
P.T POST TENSION AA MA NS
1
BASEMENT 01 LEVEL - BOTTOM REINFORCEMENT PLAN - OVERALL D.P DROP PANEL 1 : 350 A1
1 08.06.2017 24.08.2017 24.08.2017
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202
SCALE 1 : 350 2. FOR SLAB REINFORCMENT SCHEDULE REFER TO DWG. 00-S6301 Drawing Number Rev.
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308 14011603-01-00-SRB0999 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

PLOT LIMIT
DUBAI MUNICIPALITY STAMP:

N
11 1.D 01

Q
34
AB

0
950

820
625
1.C

0
0
1.B
0 15 02 N
220 AB KEY PLAN
10 A
0
800
00
220

AB

600
0
950

21

0
1.A

AB

820
18
AB

0
34

20
AB
00
120

AB
1.01

ME

375

13
SH

0
T20
500
9 0
0 300

@1
600

mm
14
AB

AB

50
32

TH

T&

AB
ICK

B(
PLOT LIMIT

14
.R

BW
AF

)
21
General Notes:

T
AB

820
AB 000
0

600
675 1. DO NOT SCALE FROM THIS DRAWING.

0
21

0
9
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
20
6000

NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED


AB

AB
0 1.02 BY THE ENGINEER.
AB3 600

AB

13
2

20
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
0
8 300 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
AT SITE.
21
AB

600
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
0
600

AB
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

21
AND RELEVANT SECTIONS OF THE SPECIFICATION.
350

32
AB
0

820
33
AB

0
600
750

0
600

0
0

3
AB

AB
1.03

13
AB
3
0 0
950 300
7 AB
21
AB

600
AB

AB
0
13

21
0
900
700

ME

820
0

SH
0
300

0
T20
600
0

@1
600

50
10
AB

T&

AB
15 1.04

B(
AB

AB

13
BW
20

)
0
300
600

21
AB
0

6
AB

AB
AB
0
455
13

21
28
115
00

820
0

0
300 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
10

600
AB 0
600 AUTHORITY APPROVAL 0 17.08.2017 NS
AB

0
10

Purpose of Issue Rev. Date Appoved

AB
1.05
00
300

13
00

SRB
6
115 B2

500

1
A Client:

099
AB

mm
0
300

9b
21

TH
ICK
14
AB

.
RA 28

AB
AB

FT
5

AB

14
13

0
MEYDAN L.L.C
850 P.O. Box 9305, Dubai , UAE.
600

820
T: +9714 3270000 F: +9714 3270007
0

0
E: info@dubairacingclub.com W: www.dubairacingclub.com
300 21
AB

600
0
600 Principal Consultant:

0
AB
21

AB
1.06
00
300

13
27
AB
AB
0
300
14
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
600

0
600 AB
21 www.ae-7.com
0

Hassanicor Building, 6th Floor, Al Barsha 1

AB
AB

PO Box 54115 Dubai, UAE


AB

21
13

P: +971 4 3997758 F: +971 4 3997759


4 18
0
850 Sub-Consultant:
600

820
0

0
0
300 AB
14

600
0
600

0
AB
14

AB
00
300

13
26 1.07
AB
AB

0
300
ME

21
SH
600

0
600 21
T20

AB
0

Project Name:
@1

AB
AB

AB
50

21
T&

DUBAI WATER CANAL


13

18
B(

0
3 850
BW

600

SAFA A
)

AB
0

0 21
300

13
AB
600
0
600 DUBAI-UAE
0
AB
21

26
AB Project Description:
0
AB

250
0
21

400 MIXED USE DEVELOPMENT


600

0
600
0

LEGEND: (RETAIL & RESIDENTIAL)


AB

AB

PLOT 01 / 3435338
13

18

0 R.C COLUMN CONTINUE


850
600

2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)


0

AB
R.C WALL CONTINUE
0 21
300

15
AB
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL Drawing Title:
AB

42
AB
21

R.C PLANTED COLUMN / WALL @ FLOOR LEVEL

UPSTAND BASEMENT 01 LEVEL - BOTTOM


SLAB OPENING REINFORCEMENT PLAN - PART A
P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
P.T POST TENSION
AA MA NS
D.P DROP PANEL
1 1 : 150 A1
NOTE: 08.06.2017 24.08.2017 24.08.2017
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301 Drawing Number Rev.
BASEMENT 01 LEVEL - BOTTOM REINFORCEMENT PLAN - PART A 3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
14011603-01-00-SRB0999a
1 SCALE 1 : 150
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

1.B
1.C 1.03 1.D 1.04
DUBAI MUNICIPALITY STAMP:

N
11 1.05

500
mm
TH

Q
ICK
14
AB

RA 28.

AB
FT
AB

SRB
14

1 9a
099
600
0
600

AB
1.06 N
KEY PLAN

13
10 27
AB

AB
0
300

14
21
AB

AB
AB

21
18
0 1
1.A 850 B
600

SRB0999c
0

600
0
600

0
AB
14

AB
1.07

13
26
AB
9

AB
0
300
ME

21
SH

21
T20

AB
@1

AB
AB
50

21
General Notes:
T&

18
B(

0
850
BW

600
)

AB
0

2.01 2.02 2.03 2.04 2.05 1. DO NOT SCALE FROM THIS DRAWING.
21

13
AB

600
0 AB13
600 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

0
AB

NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED


21

8200 8200 8200 8200 BY THE ENGINEER.


26
AB 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
0
AB 250 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 21 400
0 AT SITE.
0
600
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

AB
AND RELEVANT SECTIONS OF THE SPECIFICATION.

18
0
850
600

105
0

AB
21 PLOT LIMIT

00
15
AB
AB

42
AB
21

00
300 43

600
AB24
AB 15 AB13

0
AB

AB30
AB

AB

3500

3500

AB28
21

14
6000

3500

3500

3500

3500
600

7 0
600 AB13
0

0
400
AB6 AB17
AB25 AB13 AB22
AB

6000
13

AB21
0
850

AB32
1.08

6000
0 20 13000
300
850

AB
0

1000
AB

AB17
20

17500 AB21

3000
1000

AB10
2.E' AB38
2000 2000 1000
AB14 AB32
8200

600

AB31
600

AB24
AB15

AB24
AB
0

4500
6
18

AB7

7500
3000

6000
AB

7200 AB41
4000

12000
13

AB46
AB10

22000
00

14000
6000
130 6000

9500
0 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
7000
300
AB35

AUTHORITY APPROVAL 0 17.08.2017 NS


AB24

1.09
6000 AB25 Purpose of Issue Rev. Date Appoved
29
AB

AB AB10
Client:
20

7000 5500 3000


4550

AB7 AB47
8700
600

AB22

AB23
5 2.F'
0

1000

1000

1000

1000
MEYDAN L.L.C

9000
AB16

7000
0 1000
850
AB10 AB10 AB14 AB20
3000

2200
2000 1250 4700 2680 P.O. Box 9305, Dubai , UAE.

9000

9000
11200

AB14
4550

T: +9714 3270000 F: +9714 3270007

AB32

AB32
AB5
8500
E: info@dubairacingclub.com W: www.dubairacingclub.com
AB26

2.G' AB47 AB25


Principal Consultant:
MESH T20@150 T&B (BW)

5000
AB47

AB20
6000 6000 6000

AB9
AB39 AB14

4000 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


9500

AB25
AT40
6000

www.ae-7.com
AB14

500mm THICK. RAFT Hassanicor Building, 6th Floor, Al Barsha 1


AB

AB18
6000

9500
PO Box 54115 Dubai, UAE
13

1.10 MESH T20@150 T&B (BW)


P: +971 4 3997758 F: +971 4 3997759
AB15

4
Sub-Consultant:

AB22

9000
0 3000
300 3500 12000
AB14 AB14
4000
AB7 AB14 AB14

6000
AB17

AB17

AB19
6000

6000

6000
8200

AB16
2.H'
AB35

6000 6000 6000 6000


8000

AB14 AB14
Project Name:

AB18
4000
AB38

AB38

AB13 AB13
AB13 AB13 AB13
DUBAI WATER CANAL
4500

4500

1600
1600
3
AB6

2000
2100
2500

1.11 6000
4000 SAFA A
6000 6000
DUBAI-UAE

PLOT LIMIT
Project Description:

PLOT LIMIT
MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
LEGEND:
PLOT 01 / 3435338
2 2200 14500 5600 R.C COLUMN CONTINUE BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
R.C WALL CONTINUE
Drawing Title:
1B' 1C' 03 04
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

R.C PLANTED COLUMN / WALL @ FLOOR LEVEL BASEMENT 01 LEVEL - BOTTOM


UPSTAND
REINFORCEMENT PLAN - PART B
SLAB OPENING

P.C. PLANTED COLUMN


BASEMENT 01 LEVEL - BOTTOM REINFORCEMENT PLAN - PART B P.W. PLANTED WALL Scale Drawn Checked Approved Size

1 1 SCALE 1 : 150
C.I.P.
P.T
CAST IN PLACE
POST TENSION 1 : 150
AA MA NS
A1
D.P DROP PANEL 08.06.2017 24.08.2017 24.08.2017
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202
Drawing Number Rev.
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508 14011603-01-00-SRB0999b 0
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

2.12
DUBAI MUNICIPALITY STAMP:
2.11
2.10

N
11
2.09 9500 2.A
2.08
2200

Q
9500
2800

8200
N
10 KEY PLAN

PLOT LIM
2.B

IT

8200
PLOT LIMIT

AB32
C
9 8900

2.C
1
SRB0999b General Notes:
W)
150 T&B (B
MESH T20@
1. DO NOT SCALE FROM THIS DRAWING.
3000
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

AB21

8200
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
2.D
2.05 2.06 2.07 3000
AB13

6000
AB7

8200 12300

AB32
AB20

AB13
3000 3000

8200
AB21

4500
7

AB34

6000
AB9
AB17
MESH T20@150 T&B (BW) 13000

6700
2.E
AB20
AB17 9000
AB37

AB10
AB13

6000
AB14
3000
AB28

AB30

AB20
AB30
3500

4500

6000
12000 7000 6000
AB48 6000

8200
AB45
6 10000

AB44
7500

1000
MESH T20@150 T&B (BW)
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

1000
AUTHORITY APPROVAL 0 17.08.2017 NS
AB21 2.F
2.E'
AB20 3000 Purpose of Issue Rev. Date Appoved
6000
1000 AB21 Client:

6000
AB20
AB9
AB24

AB9
6000

AB21
9000
AB14

9000
AB21
12000

5
MEYDAN L.L.C

8200
3000
22000

6000 AB17
6000

6000 P.O. Box 9305, Dubai , UAE.


1000
9500

T: +9714 3270000 F: +9714 3270007


ICK. RAFT

1000
6000 AB21` 500mm TH E: info@dubairacingclub.com W: www.dubairacingclub.com
4000
AB25 Principal Consultant:
AB35

AB21

AB42
18700

2.G
AB13
6000
7000

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

6000
www.ae-7.com

AB20
AB23

2.F' AB21 AB21 Hassanicor Building, 6th Floor, Al Barsha 1

6000
AB9

AB2

AB21
PO Box 54115 Dubai, UAE
27000

AB20
P: +971 4 3997758 F: +971 4 3997759

AB21
4
2200

9000

6000
10000

AB17
Sub-Consultant:

8200
2.G' AB20 6000
AB25 6000 10000
6000
6000 5000 6000 W)
150 T&B (B
MESH T20@

AB1
AB25 AB36

2.H
6000
9500

Project Name:

4000
6000
MESH T20@150 T&B (BW) 6000 AB20
AB14 6000
DUBAI WATER CANAL
9000

6000
AB20
3
9000

AB34
AB14 AB20
6000

6000

SAFA A
AB1

AB14
AB31

AB16

9000
AB19

PLOT LIMIT DUBAI-UAE


AB2
9000

2.H'
Project Description:
6000
6000
MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)

AB5
AB13 LEGEND:
1600

R.C COLUMN CONTINUE PLOT 01 / 3435338


2 R.C WALL CONTINUE BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL Drawing Title:
PLOT LIMIT R.C PLANTED COLUMN / WALL @ FLOOR LEVEL

UPSTAND BASEMENT 01 LEVEL - BOTTOM


SLAB OPENING REINFORCEMENT PLAN - PART C
P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE
P.T POST TENSION
Scale Drawn Checked Approved Size
D.P DROP PANEL
AA MA NS
1 1 : 150 A1
NOTE: 08.06.2017 24.08.2017 24.08.2017
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202
BASEMENT 01 LEVEL - BOTTOM REINFORCEMENT PLAN - PART C 2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301 Drawing Number Rev.
1 3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
14011603-01-00-SRB0999c
SCALE 1 : 150 4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

N
11

Q
T
L IMI
OT
PL

1.D 01 N
10 KEY PLAN
0
1.C 950

820
0
1.B 0 02
220

0
1.A 950

820
0
1.01
IT
LIM
OT
PL

820
9

0
1.02

PLOT LIMIT General Notes:

820
0
1.03
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

820
2.12 BY THE ENGINEER.

0
1.04 2.10 2.11 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
2.09 9500
2.08 2200 2.A SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 9500 AT SITE.
2800
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

820

8200
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

SRT
0

1
1.05 AND RELEVANT SECTIONS OF THE SPECIFICATION.

099
9b
2.B

820

SRT
1 9a
0

099

8200
1.06

1 1 2.C

820
7 SRT0999c SRT0999b

0
1.07

8200
2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.D

8200 8200 8200 8200 8200 12300

8200
PLOT LIMIT
2.E

8200
1.08

2.F
2.E' 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
8200

AUTHORITY APPROVAL 0 17.08.2017 NS

8200
Purpose of Issue Rev. Date Appoved
9500

1.09 Client:
2.G

2.F'
2200
11200

8200
5 2.G'
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
2.H T: +9714 3270000 F: +9714 3270007
9500

E: info@dubairacingclub.com W: www.dubairacingclub.com
1.10
Principal Consultant:
PLOT LIMIT
8200

2.H'

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


1.11 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 PLOT LIMIT
Sub-Consultant:
2200 14500 5600

1B' 1C' 03 04

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 LEGEND: BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
R.C COLUMN CONTINUE Drawing Title:
R.C WALL CONTINUE
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL BASEMENT 01 LEVEL - TOP
UPSTAND
SLAB OPENING REINFORCEMENT PLAN - OVERALL
P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
P.T POST TENSION AA MA NS
1 BASEMENT 01 LEVEL - TOP REINFORCEMENT PLAN - OVERALL D.P DROP PANEL 1 : 350 A1
1 SCALE 1 : 350
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202
08.06.2017 24.08.2017 24.08.2017

2. FOR SLAB REINFORCMENT SCHEDULE REFER TO DWG. 00-S6301 Drawing Number Rev.

14011603-01-00-SRT0999
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

PLOT LIMIT
DUBAI MUNICIPALITY STAMP:

N
11 1.D 01

5
AT

Q
400
0

AT

0
300

5
0
950 7

AT
16 AT

820
600
11
1.C AT

0
0
0
650

AT
1.B

300
N

23
02
KEY PLAN

0
0
10 220 0 A
300
1
AT

AT
16

AT
11
AT

1
0
950
0
0 925
1.A 650

AT
600
300

820
12
0
0

0
1

325
AT

0
AT
3 00
115

AT
300
3 1.01
AT

18
0

AT
9 2

3
T2

300
A
0 0
600 0 300

0
1
925
AT

AT
9

600

AT
PLOT LIMIT

1
General Notes:
3000 0
500

AT

820
0 1. DO NOT SCALE FROM THIS DRAWING.

600
AT
675

12

0
1

0
AT3

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

AT
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
6000

12
AT BY THE ENGINEER.
1.02

AT
0
AT9 600

AT

1
0
675
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

2
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

500
8 0
300
140
AT SITE.

ME
mm
00

SH
1

TH

160
AT 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

T20
ICK
600
AT

00
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

@1
0
600

AT
RA
15

0
AND RELEVANT SECTIONS OF THE SPECIFICATION.

50
1
FT
1
350

T&
9 AT 30
AT AT

B(
0

BW

820
AT

0
300

0
1

600
0
600

0
3
AT
0

AT
400 1.03

18
AT
AT

3
0
21

AT
9
0 300
7 400
18
AT
600

0
600

600
0
0

AT
AT

600

18
3

AT
18

820
0
300

0
490

600
0
AT
21
0 600
0

0
200
39 1.04

AT
11 42 AT
AT 00

3
AT
200

28
AT
0

0
18

11 300
AT 0
170 1
AT
485

6 AT
675
600

37
0

0
0

AT

AT
490
1

1
29
0

AT
AT
18

820
0 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

0
300

275
46 00 AUTHORITY APPROVAL 0 17.08.2017 NS

600
AT 160 0

00
21 600

0
AT Purpose of Issue Rev. Date Appoved
1.05

AT
Client:
400

SRT
17

1
AT
0

099
AT
0
300

9b
11
AT

18
AT
40

1
AT

500
600

mm
0

AT
AT

MEYDAN L.L.C

TH

1
1

ICK
0 P.O. Box 9305, Dubai , UAE.
850

.
T: +9714 3270000 F: +9714 3270007
600

RA

820
E: info@dubairacingclub.com W: www.dubairacingclub.com

FT
0

0
300 AT
1
Principal Consultant:

600
0
600

0
AT
1

1.06

AT
3
7
A T1
AT

0
1 300 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
18

A T1 www.ae-7.com
600

ME

0
600 AT
1 Hassanicor Building, 6th Floor, Al Barsha 1
SH
0
600

PO Box 54115 Dubai, UAE


T20

AT
0

AT

P: +971 4 3997758 F: +971 4 3997759


@1

1
1

50

0 Sub-Consultant:
850
T&

600
B(

820
BW

0
0
300
)

1
AT

600
0
600

0
AT

775
1

0
AT
3
25 1.07
AT
AT

0
11 00 300
23
AT

AT 180
600

0
600
12

1 Project Name:
AT
0
600

AT
0

DUBAI WATER CANAL


AT

31

1
AT
1

3 0
850
SAFA A
600

32
0

0 AT

300
300
1
AT
600

0 DUBAI-UAE

0
600
0
AT
1

25 Project Description:
AT

625
AT

MIXED USE DEVELOPMENT

0
11
23

AT
600

0
600
(RETAIL & RESIDENTIAL)
AT
0

LEGEND:
600

11
0

AT

40 PLOT 01 / 3435338
1

0 AT R.C COLUMN CONTINUE


2 850 850
0
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
600

31 R.C WALL CONTINUE


0

0 AT
300

AT
1
AT Drawing Title:

40
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
42
AT

AT R.C PLANTED COLUMN / WALL @ FLOOR LEVEL


1

UPSTAND
BASEMENT 01 LEVEL - TOP
SLAB OPENING REINFORCEMENT PLAN - PART A
P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
BASEMENT 01 LEVEL - TOP REINFORCEMENT PLAN - PART A P.T POST TENSION AA MA NS
1
D.P DROP PANEL 1 : 150 A1
1
NOTE: 08.06.2017 24.08.2017 24.08.2017
SCALE 1 : 150
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301 Drawing Number Rev.
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308 14011603-01-00-SRT0999a 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


1.C 1.03 1.D 1.04
1.B

N
11

1.05

Q
AT
18
1
AT

500
mm

AT

SRT
1 9a
TH

099
ICK
0
850

RA.
FT
N

600
10 600
0 KEY PLAN

0
1.06

AT
3
7
A T1

AT
0
300

18
ME

1
AT
SH

B
T20

AT
@1

1
50

0 1
1.A 850
T&

600
B(

SRT0999c
BW

0
)

600
0
600

0
AT

775
9
1

0
1.07

AT
3
5
A T2

AT
0
300

23
AT

General Notes:
12

1
AT

AT
31

1
AT 1. DO NOT SCALE FROM THIS DRAWING.
0
850
600

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


32
0

2.01 2.02 2.03 2.04 2.05 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
AT

300
1 BY THE ENGINEER.
AT

600
0

0
600

0
AT

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


1

SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK


8 8200 8200 8200 8200
AT SITE.
25
AT

625
AT

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

0
00
23

ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS


0 225
600
AND RELEVANT SECTIONS OF THE SPECIFICATION.

AT
11
40
0 AT
850 850
0
600

31
0

AT PLOT LIMIT

AT
1
AT

40
42
AT

AT
1

25 12500 4000 6000 6000 6000


7

600
AT

300
5
T1

0
AT

AT

AT23

AT50

AT48

AT49
A

3500

3500

3500

3500

3500
23

11
850

19
AT
600

0 AT15
600
AT2 AT1 AT23 AT1
0
0

0
400
AT31 AT23
600

AT1
0

AT

6000
1

AT23
0
850

AT8
1.08 14350

6000
0
300
1 2000
AT
850
0
AT

AT3
1

17500 AT2 AT1

3000
AT9
2.E' AT18
6 2000 2000
11
8200

600

AT 0

AT43
600
0

925

AT2

AT2
AT29
AT51

6000
600

AT17

3000
0

AT

AT44
AT1 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
1

14350
6000
6000 AUTHORITY APPROVAL 0 17.08.2017 NS

9500
3750
7000
Purpose of Issue Rev. Date Appoved
2500

9500
0
300

2AT45
AT28

18000
7000

1.09

18000
AT2

Client:
AT52
AT31

6000

26
AT

AT AT1
1

8000 5500
AT11
3650

3250

AT41
2600

5 AT11
AT52
2950
AT52
MEYDAN L.L.C
600

P.O. Box 9305, Dubai , UAE.


2.F' T: +9714 3270000 F: +9714 3270007
0

1275 E: info@dubairacingclub.com W: www.dubairacingclub.com

9000
0 AT45
850

2200
AT19

AT45
AT45

Principal Consultant:

1300
11200

AT39

9000
AT2
3650

AT15 AT19
8500
AT40

3750 1500 3500 3500


2.G'

AT3

AT10

AT10
AT2
6000 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

9000
AT33 AT3 6000 6000 www.ae-7.com
11 Hassanicor Building, 6th Floor, Al Barsha 1
AT PO Box 54115 Dubai, UAE
4000
9500

6000
AT34

P: +971 4 3997758 F: +971 4 3997759


6000

4
600

AT35
AT2

MESH T20@150 T&B (BW) 500mm THICK. RAFT


0

AT

Sub-Consultant:
6000

9500
1

1.10
AT35

AT2 AT2 AT2


0 AT2
300 3500 4000 AT2
6000 4000
AT41

9000
4000

9000
8200

9000
9000

MESH T20@150 T&B (BW)

9000
2.H' Project Name:
AT39

1
A T1
AT37 AT3 AT15
DUBAI WATER CANAL
600

3
0

AT10
2AT42

AT12
SAFA A
AT

AT36

AT35

AT43
AT13
1

4500

4500

4000

4000

6000
AT43

6000 14000
1.11 6000 DUBAI-UAE
4000
0 5000 6000 4000
300
Project Description:

PLOT LIMIT MIXED USE DEVELOPMENT


LEGEND:
(RETAIL & RESIDENTIAL)
PLOT LIMIT PLOT 01 / 3435338
R.C COLUMN CONTINUE
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
R.C WALL CONTINUE
Drawing Title:
2200 14500 5600 R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

1B' 1C' 03 04
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL
BASEMENT 01 LEVEL - TOP
UPSTAND

SLAB OPENING
REINFORCEMENT PLAN - PART B
P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
P.T POST TENSION AA MA NS
1
BASEMENT 01 LEVEL - TOP REINFORCEMENT PLAN - PART B D.P DROP PANEL 1 : 150
08.06.2017 24.08.2017 24.08.2017
A1
1 SCALE 1 : 150
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202 Drawing Number Rev.
2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
14011603-01-00-SRT0999b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

2.12 DUBAI MUNICIPALITY STAMP:


2.11
2.10

N
11 2.09 9500 2.A
2.08
2200
9500

Q
2800

8200
N
10 KEY PLAN

PLOT LIM
2.B

IT

8200
AT9

3000

AT9
PLOT LIMIT AT9

3000

AT9
3000 C
9 3000

2.C
1
W)
SRT0999b 150 T&B (B
MESH T20@ General Notes:
AT27
AT9 1. DO NOT SCALE FROM THIS DRAWING.

3000
AT9 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

AT9
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

8200
3000

AT9
3000 BY THE ENGINEER.

3000 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
2.D AND RELEVANT SECTIONS OF THE SPECIFICATION.
2.05 2.06 2.07

8200 12300 AT9

7000
AT11

AT9
AT26 AT1

3000

AT26

AT47
3000

8200
3000

3000
6000

AT16
AT18
7 3000
12300

MESH T20@150 T&B (BW)

11000
2.E

AT37
6000 6000 6000 5000

AT2
AT49

AT48

AT48

AT49
3500

3500

AT1 AT1 AT23 3500 6000 6000

1850
AT3

8200
3000

AT18
6 AT38
ICK. RAFT

AT19

AT1
500mm TH
7000
5000

11300
MESH T20@150 T&B (BW) AT12
AT2 6000 0
100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS

6000
4500
AT2 AT1 2.F
AT1 7500 AUTHORITY APPROVAL 0 17.08.2017 NS

5000
2.E' 325 1550 Purpose of Issue Rev. Date Appoved

AT2
AT4 AT5

AT3
Client:

AT15

6000
AT3

6000
AT2
AT2

AT21
6000

AT14 3000
6000 5000 6000

3500
6000

8200
5 7500
6000
MEYDAN L.L.C

5000
P.O. Box 9305, Dubai , UAE.
AT19 T: +9714 3270000 F: +9714 3270007

AT36
E: info@dubairacingclub.com W: www.dubairacingclub.com
6450
AT2 AT2 Principal Consultant:
AT1
5000 AT2 2.G

AT8
AT2
4800

3550

AT2
AT28
30000

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

AT2

9000
2.F'

6000
www.ae-7.com

6000
AT3
4000 Hassanicor Building, 6th Floor, Al Barsha 1
9000

9000

PO Box 54115 Dubai, UAE


9000

P: +971 4 3997758 F: +971 4 3997759


4 AT3
6000 AT3

8200
2.G' 6000
Sub-Consultant:
AT1
AT6

AT6
AT10
AT10

4500

6000 6000
6000 W)
6000 6000 150 T&B (B 4000
MESH T20@

AT3
AT1
500mm THICK. RAFT AT3 2.H
AT24
AT3 Project Name:

AT12

3000
AT1 AT3

6000
AT2 AT1

3 AT3
6000
DUBAI WATER CANAL
6000

SAFA A
AT2
AT43

9000

6000 PLOT LIMIT


6000
AT2

AT3
9000

DUBAI-UAE
9000

6000
2.H' 6000
6000
Project Description:

MIXED USE DEVELOPMENT


AT10

6000
AT10

6000
6000
LEGEND:
(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
R.C COLUMN CONTINUE
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
R.C WALL CONTINUE

PLOT LIMIT Drawing Title:


R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

R.C PLANTED COLUMN / WALL @ FLOOR LEVEL

UPSTAND
BASEMENT 01 LEVEL - TOP
SLAB OPENING
REINFORCEMENT PLAN - PART C
P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
P.T POST TENSION AA MA NS
1 D.P DROP PANEL 1 : 150 A1
08.06.2017 24.08.2017 24.08.2017
NOTE:
BASEMENT 01 LEVEL - TOP REINFORCEMENT PLAN - PART C 1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202 Drawing Number Rev.
1 2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
14011603-01-00-SRT0999c
SCALE 1 : 150 3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

N
11

Q
N
10 IMI
T KEY PLAN
TL
P LO

1.D 01

0
1.C 950

820
1.B

0
0 02
220

0
1.A 950

820
0
9 1.01
IT
LIM
OT
PL

820
General Notes:

0
1.02
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


PLOT LIMIT

820
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

0
BY THE ENGINEER.
1.03
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

820
2.12 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

0
1.04 2.10 2.11 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
2.09 9500 AND RELEVANT SECTIONS OF THE SPECIFICATION.
2.08 2200 2.A
9500
2800

820

8200
0

SR1
1
1.05

000
b
2.B

820

SR1
0

1 a
7

8200
000
1.06

2.C
1 1

820
SR1000c SR1000b

0
1.07

8200
2.01 2.02 2.03 2.04 2.05 2.06 2.07 2.D

8200 8200 8200 8200 8200 12300

8200
6
50mm EXPANSION JOINT
2.E

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

8200
AUTHORITY APPROVAL 0 17.08.2017 NS
1.08 Purpose of Issue Rev. Date Appoved
2.F
2.E' Client:
8200

8200
9500

5 1.09

2.G MEYDAN L.L.C


P.O. Box 9305, Dubai , UAE.
2.F' T: +9714 3270000 F: +9714 3270007
2200

E: info@dubairacingclub.com W: www.dubairacingclub.com
11200

8200
2.G' Principal Consultant:

2.H
9500

1.10
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
PLOT LIMIT
8200

Hassanicor Building, 6th Floor, Al Barsha 1


2.H' PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
1.11
Sub-Consultant:

PLOT LIMIT

2200 14500 5600

1B' 1C' 03 04

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 LEGEND: BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
R.C COLUMN CONTINUE Drawing Title:
R.C WALL CONTINUE
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL GROUND LEVEL - REINFORCEMENT
UPSTAND
SLAB OPENING PLAN - OVERALL
P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE Scale Drawn Checked Approved Size
P.T POST TENSION AA MA NS
1 D.P DROP PANEL 1 : 350 A1
GROUND LEVEL - REINFORCEMENT PLAN - OVERALL NOTE: 08.06.2017 24.08.2017 24.08.2017
1 SCALE 1 : 350
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202
2. FOR SLAB REINFORCMENT SCHEDULE REFER TO DWG. 00-S6301 Drawing Number Rev.

14011603-01-00-SR1000
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

PLOT LIMIT
DUBAI MUNICIPALITY STAMP:

N
11 1.D 01

Q
0
950

820
1.C

0
1.B
0 02 N
10 220 KEY PLAN A
0
300

RA
MP

1A
1

T1
0
950

6
1.A

820
0
1A
T8
0

300
T1 0
1A 550

0
1.01

600
B2

166
1A

210
0
00

00
1A
0
120

00
600

350

B1
mm
PLOT LIMIT

. TH

600
General Notes:

1A
ICK
0

0
0
T1 550

300

T8
1A
C.I

P.S
0
ME

.P
T1

820
.1
SH

1A
SL
1. DO NOT SCALE FROM THIS DRAWING.

1A

0
5
AB T1
T25

B4

T1
1A 1A 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
@1
50

NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED


T&

0 1.02 BY THE ENGINEER.


600
B(
BW

400

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


)

600
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8

0
AT SITE.

P.S
00 T3 T2

.1
1A T2
105
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
1A

1A 1A

400
1A
0 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
T9

300
400 300

mm
T2
AND RELEVANT SECTIONS OF THE SPECIFICATION.

0
. TH
0

ICK
600

1A
ME

820
800
1A
T9
C.I
SH

0
T2

0
.P
T20
600

SL
@1

AB
0

50
1A

B3
P.S

T&
T3 1A 1.03
T3

775
B(
.1

1A T1

BW
1A

0
300
6

)
T1
1A

mm

350
. TH

775
7

mm
ICK

0
0
800

. TH
C.I
ME

.P

ICK
SH

SL

C.I
T20

AB

.P
ME
1A

@1

SL

820
SH
T8

50

AB
0
1A

420

0
T20
T&
T9

B(

@1
BW

50
00
136

T&
300

B(
1.04

200
0

BW
1A
0
1

)
1A
AT

T9
1 8 T9

T9
T1 T4
1A 1A 1A
0
400

160
300
6 T1
5 00
160

00
1A 0

1A
400
T5

T6
1A

0
5 T5
850

T1 1A

820
400
1A 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
0

0
0
8 0
T1 400 0
1A NS
ST 00

AUTHORITY APPROVAL 17.08.2017


300
1-0
2

B5 Purpose of Issue Date Appoved


2

1A Rev.
850

1A
1.05

1A
0

T6

T5
0 Client:

550
800

350
T5

0
ME

1A

mm
SH

P.S

. TH
0
400
T20

.2

300

SR1
ICK

1
@1

000
C.I
50

b
1A

.P
MEYDAN L.L.C
P.S
T&

410
350

SL
T5
B(

.2

AB

00
mm

1A
BW

P.O. Box 9305, Dubai , UAE.


5
. TH

T6 AT
)

T: +9714 3270000 F: +9714 3270007

820
300
9 1
T1
ICK

E: info@dubairacingclub.com W: www.dubairacingclub.com

0
1A

ME
0
0
C.I

300

400

SH
ME

00 Principal Consultant:
.P

400

T8 198
mm
SH

T20
1A
SL

400
0

. TH
T20

AB

@1
0

0
400 1.06
ICK
@1

50
400

T&
0
50

0
860
1A
C.I

T2

B(
0
T&

1A
.P

1A
T9

BW
1A
B(

SL

T9
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
T7
BW

)
AB

ME
0
400
www.ae-7.com
)

SH
Hassanicor Building, 6th Floor, Al Barsha 1

T20
6
T1 0 PO Box 54115 Dubai, UAE
400

1A
@1
1A

400
T5 P: +971 4 3997758 F: +971 4 3997759

T6
50
4
400

1A

0
T&
350

Sub-Consultant:
0

300

B(
00 T5
mm

BW

820
1A

400
109
mm
. TH

0
0
. TH

T8
1A
ICK

ICK

B5
ME

1A

1A
C.I

C.I
T9
SH

.P

350
.P

275
T20

SL

400
SL

mm

1A
AB

00
@1

400
AB
400

1.07

. TH

T6
1A
50

0
0

0
400

ICK

350
400

T1
T&

0
B(

mm
C.I
2
T1
BW

.P

. TH
T5 1A T5 T5

SL
)

1A 1A Project Name:
1A

ICK
0

AB
6
450
5
T1 AT

1A
1A

C.I
1

400
DUBAI WATER CANAL
1A

T6

.P
0

SL
T1
350

3
P.S

300

AB
0
mm

400

.3

SAFA A
1A

0
. TH

ME
T1

SH
0
ICK

0
ME

400
400

DUBAI-UAE

20@
300
C.I
SH

ME
0
.P

0
T5

150
T20

SL

SH

0 1A
880
AB

T&
@1

T20

B(
Project Description:
50

6
@1

T1

BW
T5
T&

1A
50

1A

)
1A
B(

MIXED USE DEVELOPMENT


T&

0
T9
BW

550
B(
)

2
400

BW

T1
1A (RETAIL & RESIDENTIAL)
)
0

1A

LEGEND:
T1

PLOT 01 / 3435338
300
0
P.S

mm

R.C COLUMN CONTINUE


400

BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)


.3

2
. TH
1A

ICK
T1

R.C WALL CONTINUE


0

C.I

0 Drawing Title:
400
.P
ME

R.C COLUMN / WALL STOPPING @ FLOOR LEVEL


SL
AB
SH

GROUND LEVEL - REINFORCEMENT


T20

R.C PLANTED COLUMN / WALL @ FLOOR LEVEL


6
@1

T1 5
1A AT
50

PLAN - PART A
1 UPSTAND
T&
B(

SLAB OPENING
BW
)

P.C. PLANTED COLUMN


P.W. PLANTED WALL Scale Drawn Checked Approved Size
C.I.P. CAST IN PLACE
AA MA NS
P.T POST TENSION
1 D.P DROP PANEL
1 : 150 A1
08.06.2017 24.08.2017 24.08.2017
NOTE:
GROUND LEVEL - REINFORCEMENT PLAN - PART A 1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202 Drawing Number Rev.
1 2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
14011603-01-00-SR1000a
SCALE 1 : 150 3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

1.D
DUBAI MUNICIPALITY STAMP:
1.03 1.04

N
11
1.05

Q
1.C

350
mm
. TH
1.B

ICK
C.I
.P
SL
AB
300

ME
0
0
400

SH
N
KEY PLAN

T20
10

@1
1.06

50
T&
0
860

B(
1A

SR1
BW

1 a
T9

000
)
ME
0
400

SH
T20
1.A 0 B
400

1A
@1

400
T5

T6
50
1A

0
T&
300

B(
T5 1

BW
1A

400
mm

SR1000c

0
. TH
ICK

B5
1A

1A
C.I
T9

350
.P

9 0
400 1.07
SL

mm

1A
400
AB

. TH

T6
1A
0
0
400

ICK

350
400

T1
0

mm
C.I
2
T1

.P

. TH
T5 1A T5 T5
General Notes:

SL
1A 1A 1A

ICK
0

AB
450 1A
T5

1A

C.I
400
1A

T6

.P
0
1. DO NOT SCALE FROM THIS DRAWING.

SL
T1
350

P.S

300

AB
0
mm

400

.3
1A

0
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
. TH

2.01 2.02 2.03 2.04 2.05

ME
T1

NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

SH
0
ICK

0 BY THE ENGINEER.
400
400

20@
300
C.I

ME
0
.P

0
T5

150
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SL

SH

0 1A 8200 8200 8200 8200


880 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
AB

T&
T20

B(
6 AT SITE.
@1

T1

BW
1A T5
50

1A

)
1A
5 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
T&

0 T1

T9
550 1A ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
B(

2
400

BW

T1 AND RELEVANT SECTIONS OF THE SPECIFICATION.


1A
)
0

1A
T1

300

1A
0

1A
P.S

mm

T1
400

T7
0

400
.3

370

7
. TH
1A

0
ICK

0 PLOT LIMIT
300
T1

0
880 50mm. EXPANSION JOINT
0

C.I

350mm. THICK C.I.P SLAB


400

0
400
.P
0

ME

SL
AB
SH

1A
T20

6 T1
@1

7 T1 T5 0 3
1A 2AT8

2AT1
1A T1
50

1A
T&

0 350mm. THICK C.I.P SLAB


40000
B(

550 MESH T16@150 T&B (BW)


400

BW

4000
0

MESH T20@150 T&B (BW)

2AB1
1A

40000
350

P.S

T1
550
mm

0
.4

1.08
0
. TH

T5
1A MESH T20@150 T&B (BW)
ICK

7200
6000
ME

3000

2AB1
550

4000

4000
400
C.I
SH

1AT13

4000
0

2AT1
.P

4000
4000 3000 6000 7600 2AT9
T20

SL

300mm. THICK C.I.P SLAB


AB

250mm. THICK C.I.P SLAB

2AT2
@1

2AT2

2AT2
1A

2.E'
50

6
T1 1AT16
T1
T&

1A 2AT6 2AT9 2AT9 2AT1 2AT8


0

6
B(

1300
2AT6
BW

350mm. THICK C.I.P SLAB


8200

MESH T20@150 T&B (BW) 1AT15

2AT8
)

400

1AT20
ST2-01
0

4350
2AT2 200

2AT1

2AT2

2AT2
2AT1
MESH T16@150 T&B (BW)

4000
300mm. THICK C.I.P SLAB 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
9000

4000 3000 6000 6000 6000


AUTHORITY APPROVAL 0 17.08.2017 NS
8000

4000
8000
Purpose of Issue Rev. Date Appoved
1A

8000
MESH T20@150 T&B (BW)
2AT9
T3

1.09 2AB1
0
Client:
400
600

1AT20

4000
0

4000
3500 6000
6000
5 2AT15 6000 6000

33000
AT
1AT16

5 1
350mm. THICK C.I.P SLAB
ESCALATOR
MEYDAN L.L.C
2.F' P.O. Box 9305, Dubai , UAE.

9000

9000

9000

9000
2AT3

2AT3

2AT3
1AT16
350

T: +9714 3270000 F: +9714 3270007

2AT4
MESH T16@150 T&B (BW)

2AT12
24000
mm

E: info@dubairacingclub.com W: www.dubairacingclub.com
. TH
11200

Principal Consultant:
180

ICK

ST1-01
4090
00

8 200 2.G'
C.I

1 AT 2AT15
.P

1AT14
SL

4000
AB

2AT7 2AT7 2AT7 2AT6


abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
10400
ME

1AT7

300mm. THICK C.I.P SLAB www.ae-7.com


1AT7

2AB1
SH

1AT13 Hassanicor Building, 6th Floor, Al Barsha 1


T20

PO Box 54115 Dubai, UAE


MESH T20@150 T&B (BW)
@1

P: +971 4 3997758 F: +971 4 3997759


4500
4500

4
50
T&

350mm. THICK C.I.P SLAB 300mm. THICK C.I.P SLAB Sub-Consultant:


B(

1.10

5500

5500
5500
BW

6000
3500

5500
3500
1AT12
)

4000 3000 6000 6000 6000 6000


1AT15 1AT15

2AT2

2AT2

2AT5
7000 4500 2AT8 2AT8 2AT8 2AT8
2AT2

2AT5
1AT12 2AT1
2AT15 2AT2
MESH T16@150 T&B (BW)
2AT7

8700
8200

2AT8
9700

MESH T16@150 T&B (BW) 2.H'

2AT14

2AT13

2AT13
Project Name:

2AT14

3000
3000
3000
1AT15 1AT15 250mm. THICK C.I.P SLAB 4000 6000 6000 6000 6000

3000
3
3500 3500
1AT14
2AT9 2AT9 2AT9 2AT8 DUBAI WATER CANAL
3500

SAFA A
3500
1AT15

1AT16

3500

MESH T16@150 T&B (BW) MESH T20@150 T&B (BW)


1AT4

1.11 350mm. THICK C.I.P SLAB 350mm. THICK C.I.P SLAB


MESH T16@150 T&B (BW)
DUBAI-UAE
3500

Project Description:
PLOT LIMIT
MIXED USE DEVELOPMENT
LEGEND:
(RETAIL & RESIDENTIAL)
PLOT LIMIT
PLOT 01 / 3435338
2 R.C COLUMN CONTINUE BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
R.C WALL CONTINUE
2200 14500 5600 Drawing Title:
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL

1B' 1C' 03 04 R.C PLANTED COLUMN / WALL @ FLOOR LEVEL


GROUND LEVEL - REINFORCEMENT
PLAN - PART B
UPSTAND

SLAB OPENING

P.C. PLANTED COLUMN


P.W. PLANTED WALL Scale Drawn Checked Approved Size
C.I.P. CAST IN PLACE
AA MA NS
P.T POST TENSION
1 D.P DROP PANEL
1 : 150 A1
GROUND LEVEL - REINFORCEMENT PLAN - PART B 08.06.2017 24.08.2017 24.08.2017

1
NOTE:
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202 Drawing Number Rev.
SCALE 1 : 150 2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301
3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
14011603-01-00-SR1000b 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


2.12

2.11

N
2.10
11
2.09 9500 2.A
2.08

Q
2200
9500
2800

8200
2AT23
W)
150 T&B (B N
MESH T20@ KEY PLAN

2AT23
10

1500
2AT23 13050

PLOT LIM
LAB
ICK C.I.P S
350mm. TH

1500
1500 2.B
2AT23

2AB3
6000

IT
2AT16
1500

2AT17

8200
2AT20
13850
PLOT LIMIT 12100 C
9

2AB8
1750

6400
2AT21

10400
W) 2.C
200 T&B (B General Notes:
MESH T12@

2AT18
1 2AB7
SR1000b ST2-03
LAB
ICK C.I.P S

6400

2AT19
300mm. TH 200 1. DO NOT SCALE FROM THIS DRAWING.
2AT17 2150
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
9950 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
1750

8200
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
1000

2AT20
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

150 T&B (BW) 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
MESH T20@ ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
11700
2.D
2.05 2.06 2.07

2AB6
8200 12300

2AT1
3000

8200
7

MESH T20@150 B (BW)


3000 2.E
350mm. THICK C.I.P SLAB

4000

2AT9
2AT10
2AT1

26000 2AT5
W)
@150 B (B
MESH T16
6

8000

8200
LAB
ICK C.I.P S
350mm. TH
2AB4
4000

2AT5

2AB3 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


3000

MESH T20@150 B (BW)

4000
6000
2AB1

6000 3000 AUTHORITY APPROVAL 0 17.08.2017 NS


2AT5
2AT1

2AB5
4000

2AT2

9900
350mm. THICK C.I.P SLAB ST2-02 3000

4000
2AT8 2AT7 200 2.F Purpose of Issue Rev. Date Appoved
6000
2.E' 10000
Client:

2AT11
2AT8
5000

2AT7
1000
2AT1

2AT1

2AT7

33000
2AT5
2AT2

4500

8000
4500 4500
2AT1

5
MEYDAN L.L.C
2AT5
2AT1

2AT3

8200
6000 2AT3 4500
4000

P.O. Box 9305, Dubai , UAE.


5500

T: +9714 3270000 F: +9714 3270007

24000
E: info@dubairacingclub.com W: www.dubairacingclub.com

2AB1 Principal Consultant:

9000
9500

W)
6000 9000 9000 @150 B (B 3000
MESH T20 2.G
LAB 6000
ICK C.I.P S 6000
300mm. TH abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

2AT9
MESH T20@150 B (BW)
2AT3

6000 www.ae-7.com

2AT8
2AT7
2AT1 Hassanicor Building, 6th Floor, Al Barsha 1
20000

2.F'
9000

9000

2AT1
2AT3

2AT3

2AT3

450mm. THICK C.I.P SLAB PO Box 54115 Dubai, UAE


9000

2AT6

6000
P: +971 4 3997758 F: +971 4 3997759

6000
4 2AT5
2200

9000

Sub-Consultant:

6000
2AT7

8200
2.G'
2AB2 2AT7

12000
2AT6 2AT3 2AT3 2AT7

6000 2AT5

5000
2.H

5500
6000 Project Name:
9500

5500

2AT9
5500
5500

2AT1
9000
DUBAI WATER CANAL
5500

2AT9
5500

6000 9000 9000


3
2AT5
2AT5

2AT9 SAFA A

2AT14
2AT3
2AT8 2AT3 8000

2000
2AT5
2AT2

DUBAI-UAE
2AT2

2000

2AT9 PLOT LIMIT

8000 2AT9
2.H' Project Description:
2AT13
2000
2AT14
2AT14

3000

3000

3000

6000 6000
2AT8 2AT8 2AT8
2AT9 MIXED USE DEVELOPMENT
LEGEND:
2AT13

12000 (RETAIL & RESIDENTIAL)


R.C COLUMN CONTINUE PLOT 01 / 3435338
2 R.C WALL CONTINUE BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
R.C COLUMN / WALL STOPPING @ FLOOR LEVEL
Drawing Title:
R.C PLANTED COLUMN / WALL @ FLOOR LEVEL
PLOT LIMIT
UPSTAND GROUND LEVEL - REINFORCEMENT
SLAB OPENING
PLAN - PART C
P.C. PLANTED COLUMN
P.W. PLANTED WALL
C.I.P. CAST IN PLACE
P.T POST TENSION Scale Drawn Checked Approved Size
D.P DROP PANEL AA MA NS
1 1 : 150 A1
NOTE:
08.06.2017 24.08.2017 24.08.2017
1. FOR BEAM SCHEDULE REFER TO DWG. 01-S6201 TO 01-S6202 & 02-S6201 TO 02-S6202

GROUND LEVEL - REINFORCEMENT PLAN - PART C 2. FOR SLAB REINFORCEMENT SCHEDULE REFER TO DWG. 00-S6301 Drawing Number Rev.
1 3. FOR STAIRS DETAILS REFER TO DWG. 00-S5501 TO 00-S5508
14011603-01-00-SR1000c 0
4. FOR SLAB DETAILS REFER TO DWG. 00-S5301 TO DWG. 00-S5308
SCALE 1 : 150

All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
900 900
900 2300 900

750 750

900

900
750 1900 750

1 2

750

750
S5103 S5103

1 2

900

900
S5103 S5103
N
KEY PLAN

750

750
10

PC1 + PC2 PC3 + PC4 PC5 + PC6 + PC19 PC7 + PC20 + PC23
1 SCALE 1 : 50
3 SCALE 1 : 50
5 SCALE 1 : 50
7 SCALE 1 : 50

1250 1250 900 900


1
750 750
S5103
General Notes:

600

600
1. DO NOT SCALE FROM THIS DRAWING.
750 1900 1900 750

1250
1.11

150
1 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
1250

NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED


S5103
BY THE ENGINEER.
1
750
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
1 S5103

1660
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

1565
8 S5103 AT SITE.

1250
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
750
1250

ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS


AND RELEVANT SECTIONS OF THE SPECIFICATION.

PC8 PC9 PC10 PC11 + PC24


8 9 10 SCALE 1 : 50
11 SCALE 1 : 50
SCALE 1 : 50 SCALE 1 : 50
7

1
1.A S5104 1.B
1
S5103 1.D

600 400 3950 1850 2100 1200 1000 750 3325 750 450 300

6
-4.500 SSL

725
1.07
1250

-3.500 SSL 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

775
AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
675

Client:
1.01

1875
5 1
2.06 S5103
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
2475

Principal Consultant:
750 750 -6.300 SSL

750
750

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


3

750
www.ae-7.com
S5103 Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
750 1450 750 450 300 Sub-Consultant:
1500

1900

2.F'

PC14
750

1 14
750

SCALE 1 : 50 Project Name:


S5103

3
DUBAI WATER CANAL
1450

SAFA A
DUBAI-UAE
2150

2.G'
1C'
1 Project Description:
800

750 2200
S5103
2200 2200 2200 750
MIXED USE DEVELOPMENT
-3.720 SSL
(RETAIL & RESIDENTIAL)
750

PLOT 01 / 3435338
925

-4.500 SSL BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)


2
750

1.02
1.08 Drawing Title:
25
875

725

FOUNDATION DETAILS - 01

Scale Drawn Checked Approved Size


PC12 PC13 PC15 AA MA NS
1 12 SCALE 1 : 50
13 SCALE 1 : 50
15 SCALE 1 : 50
1 : 50
08.06.2017 24.08.2017 24.08.2017
A1

Drawing Number Rev.

14011603-01-00-S5101 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

2.09 2.10 DUBAI MUNICIPALITY STAMP:


900 350 3700 900 1950 2800 150 1700

11 750 1575 1825 2725 2650

900
750 03

1.09 3 750 750


25

-5.000 SSL S5103

1250

750
1175

-5.000 SSL
N
10 -4.500 SSL
KEY PLAN

1100
1050
1
3 S5103
S5103 1.11
-6.300 SSL
2200

800

800
735
770
2300
-5.000 SSL
-6.300 SSL

9
750

PC21
21 SCALE 1 : 50
General Notes:
1

1050
S5105 1. DO NOT SCALE FROM THIS DRAWING.
2.07
2.F 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
-5.000 SSL NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
875 25 900
3050

BY THE ENGINEER.

1250
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

900
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

1150
750

2250
-4.500 SSL
PC18
7 18
PC16 SCALE 1 : 50 1
16 SCALE 1 : 50
S5103

2.03
2.11 2 2.12
S5104
450 450 2300 2850 2850 1050 1250 900
1325 2500 2500 850 1650 1525

2250
900
850

900
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
1000

AUTHORITY APPROVAL 0 17.08.2017 NS


2300

2.E'
PC25 Purpose of Issue Rev. Date Appoved
25 SCALE 1 : 50
Client:
1500

5 900 900
-0.400 SSL MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

900
2075

4 Principal Consultant:
S5103

900
2700

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


-4.500 SSL 2.C www.ae-7.com
225

Hassanicor Building, 6th Floor, Al Barsha 1


-4.500 SSL PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
900

Sub-Consultant:

2 PC26 + PC28
S5104 26 SCALE 1 : 50
2700

Project Name:

3 PC22 DUBAI WATER CANAL


22 SCALE 1 : 50
SAFA A
2.11
610 140 750
DUBAI-UAE

Project Description:
750

750
04
MIXED USE DEVELOPMENT
4 900 900 275 475 750
(RETAIL & RESIDENTIAL)
600

600
S5103
2500

750 750
-4.500 SSL
2.H
PLOT 01 / 3435338

750

750
1 750 750
900

900

2 S5103 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)


4 1.11
750

-4.500 SSL
1300

1300
S5103
Drawing Title:
310

310

750
2.H

1395
1430
100

2.F'
495
750

-4.500 SSL
FOUNDATION DETAILS - 02
695

AS PER PLAN
750

720
795

4
4 S5103 Scale Drawn Checked Approved Size
AA MA NS
PC17 PC27 PC29 PC30
S5103
1 : 50 A1
1
17 27 29 30 PC31 PC32 08.06.2017 24.08.2017 24.08.2017
SCALE 1 : 50 SCALE 1 : 50 SCALE 1 : 50 SCALE 1 : 50 31 SCALE 1 : 50
32 SCALE 1 : 50 Drawing Number Rev.

14011603-01-00-S5102 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11
AS PER PLAN AS PER PLAN
FOR COLUMN REINF. DETAILS
REFER TO COLUMNS OR WALLS SCHEDULES
FOR COLUMN / WALL REINF. DETAILS
REFER TO COLUMN SCHEDULE
AS PER PILE CAP SCHEDULE

T16@300 RINGS FOR REINF. REFER


AS PER PLAN TO REINF. PLAN
T16@300 RINGS FOR REINF. REFER
AS PER PLAN TO REINF. PLAN
N
KEY PLAN

500
10

AS PER RELATED PILE CAP SCHEDULE


Ld Ld

AS PER RELATED PILE CAP SCHEDULE


50MM PROTECTION WATER PROOFING
WATER PROOFING SCREED AS PER SPEC.
50MM PROTECTION AS PER SPEC. WATER PROOFING AS PROTECTION BOARD
SCREED
PROTECTION BOARD PER PROJECT SPECT.
WATER PROOFING AS BLOCK WORK 200mm
PER PROJECT SPECT. 75mm BLINDING
BLOCK WORK 200mm
9

100
75mm BLINDING COMPACTED FILL 50MM HIGH STRENGTH
50MM HIGH STRENGTH 95% PROCTOR TEST FLOWABLE EPOXY GROUT

100
COMPACTED FILL
95% PROCTOR TEST FLOWABLE EPOXY GROUT

General Notes:
50MM PROTECTION
SCREED 1. DO NOT SCALE FROM THIS DRAWING.
50MM PROTECTION
WATER PROOFING AS
SCREED 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
PER PROJECT SPECT. NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
WATER PROOFING AS PILE REINFORCMENT AS PER THE PILING CONTRACTOR PILE REINFORCMENT AS PER THE PILING CONTRACTOR BY THE ENGINEER.
PER PROJECT SPECT. COMPLYING WITH THE PROJECT SPECIFICATIONS 75mm BLINDING COMPLYING WITH THE PROJECT SPECIFICATIONS
75mm BLINDING COMPACTED FILL 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
95% PROCTOR TEST SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 COMPACTED FILL AT SITE.
95% PROCTOR TEST
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN

FOR DIMENSION AND REINFORCMENT REFER TO PILE CAP SCHEDULE FOR DIMENSION AND REINFORCMENT REFER TO PILE CAP SCHEDULE

7
SECTION 1 SECTION 2
1 SCALE 1 : 25
2 SCALE 1 : 25

FOR REINF. REFER FOR REINF. REFER


6 TO CORE WALL DETAILS TO CORE WALL DETAILS

FOR REINF. REFER FOR REINF. REFER 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
TO REINF. PLAN AS PER PLAN AS PER PLAN TO REINF. PLAN AUTHORITY APPROVAL 0 17.08.2017 NS
WALL
Purpose of Issue Rev. Date Appoved
THICK. Client:
Ld
Ld

5
MEYDAN L.L.C
1800

P.O. Box 9305, Dubai , UAE.


T: +9714 3270000 F: +9714 3270007
WATER STOP E: info@dubairacingclub.com W: www.dubairacingclub.com
50MM PROTECTION PROTECTION BOARD AS PER SPEC.
SCREED Principal Consultant:
AS PER PILE CAP SCHEDULE
WATER PROOFING AS WATER PROOFING FOR REINF. REFER
PER PROJECT SPECT. AS PER SPEC. AS PER PLAN TO REINF. PLAN
T32 @100mm -6.30 SSL Ld
Ld +T25 @200
75mm BLINDING
SHOTCRETE abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
COMPACTED FILL
95% PROCTOR TEST www.ae-7.com
SECANT PILE WALL Ld

500
Hassanicor Building, 6th Floor, Al Barsha 1
AS PER RELATED PILE CAP SCHEDULE

(REFER TO SHORING DETAILS) PO Box 54115 Dubai, UAE


P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

WATER PROOFING

AS PER SCHEDULE
AS PER SPEC. T12@300 RINGS
PROTECTION BOARD WATER PROOFING
AS PER SPEC.
50MM HIGH STRENGTH
BLOCK WORK 200mm PROTECTION BOARD
FLOWABLE EPOXY GROUT
T25@150 RINGS
BLOCK WORK 200mm
Project Name:
50MM HIGH STRENGTH

100
FLOWABLE EPOXY GROUT

3
50MM HIGH STRENGTH
FLOWABLE EPOXY GROUT
DUBAI WATER CANAL
SAFA A
DUBAI-UAE
50MM PROTECTION
SCREED
50MM PROTECTION
SCREED WATER PROOFING AS
PER PROJECT SPECT.
Project Description:
WATER PROOFING AS PILE REINFORCMENT AS PER THE PILING CONTRACTOR
PER PROJECT SPECT. COMPLYING WITH THE PROJECT SPECIFICATIONS 75mm BLINDING MIXED USE DEVELOPMENT
75mm BLINDING COMPACTED FILL
95% PROCTOR TEST
(RETAIL & RESIDENTIAL)
COMPACTED FILL
95% PROCTOR TEST PILE REINFORCMENT AS PER
PLOT 01 / 3435338
THE PILING CONTRACTOR
2 COMPLYING WITH THE PROJECT
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
SPECIFICATIONS
Drawing Title:

FOR DIMENSION AND REINFORCMENT REFER TO PILE CAP SCHEDULE


AS PER PLAN AS PER PLAN FOUNDATION DETAILS - 03
SECTION 3 SECTON 4
3 SCALE 1 : 25
4 SCALE 1 : 25 Scale Drawn Checked Approved Size
AA MA NS
1 1 : 25 A1
08.06.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-00-S5103 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


FOR REINF. REFER FOR REINF. REFER FOR REINF. REFER
TO CORE WALL DETAILS TO CORE WALL DETAILS TO CORE WALL DETAILS

11
AS PER PLAN FOR REINF. REFER
-3.50 S.S.L TO REINF. PLAN

FOR REINF. REFER


TO REINF. PLAN -3.72 S.S.L

500
Ld

Ld

N
10 KEY PLAN

50MM PROTECTION
SCREED
1405

WATER PROOFING AS
PER PROJECT SPECT.

2300
75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST
Ld
100

9
580

Ld T32 @100mm AS PER PILE CAP SCHEDULE T16@300 RINGS


-6.30 S.S.L Ld
General Notes:
+T25 @200
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
1900

1900
AND RELEVANT SECTIONS OF THE SPECIFICATION.

WATER PROOFING
AS PER SPEC.
PROTECTION BOARD

BLOCK WORK 200mm

7
100

100
50MM HIGH STRENGTH
FLOWABLE EPOXY GROUT

50MM PROTECTION
SCREED
WATER PROOFING AS
PER PROJECT SPECT.

75mm BLINDING PILE REINFORCMENT AS PER THE PILING CONTRACTOR


COMPLYING WITH THE PROJECT SPECIFICATIONS
COMPACTED FILL
6 95% PROCTOR TEST

SECTION 1 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


1 SCALE 1 : 25 AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN Client:

AS PER PLAN
5
FOR REINF. REFER FOR REINF. REFER
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
TO CORE WALL DETAILS TO CORE WALL DETAILS T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

AS PER PILE CAP SCHEDULE


FOR REINF. REFER T16@300 RINGS FOR REINF. REFER
TO REINF. PLAN AS PER PLAN AS PER PLAN AS PER PLAN TO REINF. PLAN
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE

500
Ld Ld P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

50MM PROTECTION
SCREED

1400
WATER PROOFING AS
PER PROJECT SPECT. Project Name:
75mm BLINDING

3 COMPACTED FILL
WATER PROOFING
AS PER SPEC. DUBAI WATER CANAL
95% PROCTOR TEST
PROTECTION BOARD SAFA A
BLOCK WORK 200mm
DUBAI-UAE

100
50MM HIGH STRENGTH
FLOWABLE EPOXY GROUT
Project Description:

MIXED USE DEVELOPMENT


50MM PROTECTION (RETAIL & RESIDENTIAL)
SCREED
WATER PROOFING AS PILE REINFORCMENT AS PER THE PILING
PLOT 01 / 3435338
PER PROJECT SPECT.
2 CONTRACTOR COMPLYING WITH THE BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
PROJECT SPECIFICATIONS
75mm BLINDING
COMPACTED FILL Drawing Title:
95% PROCTOR TEST

FOUNDATION DETAILS - 04

Scale Drawn Checked Approved Size


AA MA NS
AS PER PLAN AS PER PLAN AS PER PLAN 1 : 25 A1
1
08.06.2017 24.08.2017 24.08.2017
SECTION 2
2 SCALE 1 : 25
Drawing Number Rev.

14011603-01-00-S5104 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


FOR REINF. REFER FOR REINF. REFER
TO CORE WALL DETAILS TO CORE WALL DETAILS
FOR REINF. REFER
11 TO CORE WALL DETAILS

FOR REINF. REFER FOR REINF. REFER


TO REINF. PLAN -4.50 S.S.L -4.50 S.S.L TO REINF. PLAN

500

500
Ld
Ld

N
10 KEY PLAN

1300
1500

AS PER PILE CAP SCHEDULE


Ld T16@300 RINGS
Ld -6.30 S.S.L Ld

50MM PROTECTION
SCREED
WATER PROOFING AS
General Notes:

1900
PER PROJECT SPECT.
1. DO NOT SCALE FROM THIS DRAWING.
1800

75mm BLINDING
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
COMPACTED FILL
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
95% PROCTOR TEST
WATER PROOFING BY THE ENGINEER.
AS PER SPEC.
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
PROTECTION BOARD SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
BLOCK WORK 200mm
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
50MM HIGH STRENGTH

100
AND RELEVANT SECTIONS OF THE SPECIFICATION.
FLOWABLE EPOXY GROUT

50MM PROTECTION
SCREED
WATER PROOFING AS PILE REINFORCMENT AS PER THE PILING CONTRACTOR
PER PROJECT SPECT. COMPLYING WITH THE PROJECT SPECIFICATIONS
7 75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST
AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN AS PER PLAN

SECTION 1
1 SCALE 1 : 25

FOR REINF. REFER


TO REINF. PLAN 350 50 350 300
T20@150
AS PER PLAN AS PER PLAN 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
T12@150
AUTHORITY APPROVAL 0 17.08.2017 NS
T12@150
T12@150
Purpose of Issue Rev. Date Appoved
350

VAR. SSL

350
Client:

T20 @150 T20 @150


T20 @150 T20 @150 WATER PROOFING AS
PER PROJECT SPECT.
5
75mm BLINDING T20@150 MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T12@150 T: +9714 3270000 F: +9714 3270007
FOR REINF. REFER E: info@dubairacingclub.com W: www.dubairacingclub.com
-3.500 SSL TO REINF. PLAN
WATER LEVEL WATER LEVEL T16@200 PROTECTION BOARD Principal Consultant:
T20@150

WATER PROOFING
500

AS PER SPEC. abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
SECANT PILE WALL www.ae-7.com
(REFER TO SHORING DETAILS) Hassanicor Building, 6th Floor, Al Barsha 1
50mm TH. FIXABLE FILLER BOARD PO Box 54115 Dubai, UAE
4 WATER STOP P: +971 4 3997758 F: +971 4 3997759
AS PER SPEC. Sub-Consultant:
FOR REINF. REFER AS PER PILE CAP SCHEDULE
50MM PROTECTION
3750

AS PER PLAN TO REINF. PLAN


SCREED
T16@200 T12@150 T12@150
WATER PROOFING AS
PER PROJECT SPECT. T20@150 T16@150 T16@150 PROTECTION BOARD

AS PER RELATED PILE CAP SCHEDULE


75mm BLINDING SHOTCRETE Ld
COMPACTED FILL WATER PROOFING
95% PROCTOR TEST AS PER SPEC.
SECANT PILE WALL Project Name:
(REFER TO SHORING DETAILS)

SECTION 2 DUBAI WATER CANAL


3
2 SCALE 1 : 25
T12@300 RINGS
SAFA A
50MM PROTECTION
T20@150 T20@150 SCREED
FOR REINF. REFER T12@150 FOR REINF. REFER T12@150 WATER PROOFING AS DUBAI-UAE
TO REINF. PLAN TO REINF. PLAN PER PROJECT SPECT.
FOR REINF. REFER 75mm BLINDING
WATER STOP WATER STOP WATER STOP 50MM HIGH STRENGTH

100
TO REINF. PLAN -4.500 SSL Project Description:
AS PER SPEC. AS PER SPEC. AS PER SPEC. FLOWABLE EPOXY GROUT
COMPACTED FILL
AS PER PLAN 95% PROCTOR TEST MIXED USE DEVELOPMENT
(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
500

2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)


Drawing Title:
PILE REINFORCMENT AS PER THE PILING CONTRACTOR
50MM PROTECTION COMPLYING WITH THE PROJECT SPECIFICATIONS
SCREED
WATER PROOFING AS FOUNDATION DETAILS - 05
PER PROJECT SPECT. 50MM PROTECTION
SCREED
75mm BLINDING WATER PROOFING AS
PER PROJECT SPECT.
COMPACTED FILL
95% PROCTOR TEST 75mm BLINDING Scale Drawn Checked Approved Size
AA MA NS
COMPACTED FILL 1 : 25 A1
1
SECTION 3 SECTION 4-4
95% PROCTOR TEST SECTION 5-5 08.06.2017 24.08.2017 24.08.2017

3 4 5 SCALE 1 : 25 Drawing Number Rev.


SCALE 1 : 25 SCALE 1 : 25
14011603-01-00-S5105 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

FOR REINF. REFER T20@150


TO REINF. PLAN AS PER PLAN T12@150
FOR REINF. REFER T20@150

SLAB THICK.
TO REINF. PLAN AS PER PLAN T12@150

SLAB THICK.
N
10 FOR REINF. REFER T20@150 KEY PLAN
TO REINF. PLAN AS PER PLAN T12@150
WATER PROOFING AS

SLAB THICK.
PER PROJECT SPECT.
WATER PROOFING AS
75mm BLINDING PER PROJECT SPECT.

75mm BLINDING

WATER PROOFING AS
PER PROJECT SPECT.

75mm BLINDING

9 300

350
250

General Notes:
300
1. DO NOT SCALE FROM THIS DRAWING.
PROTECTION BOARD
T12@150 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
PROTECTION BOARD NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
T12@150 BY THE ENGINEER.
VAR. SSL
WATER PROOFING
AS PER SPEC. 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
WATER PROOFING SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

300
8 AS PER SPEC. AT SITE.
PROTECTION BOARD
T16@200 SHOTCRETE
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
SHOTCRETE ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
T16@200
T20@150 WATER PROOFING
AND RELEVANT SECTIONS OF THE SPECIFICATION.
T25@150 SECANT PILE WALL T12@150 AS PER SPEC.
(REFER TO SHORING DETAILS)
T20@150 SECANT PILE WALL
(REFER TO SHORING DETAILS) T16@200 SHOTCRETE
T12@200 T20@150
WATER STOP
AS PER SPEC. T12@200
WATER STOP SECANT PILE WALL
FOR REINF. REFER AS PER PILE CAP SCHEDULE AS PER SPEC. (REFER TO SHORING DETAILS)
AS PER PLAN TO REINF. PLAN
7 FOR REINF. REFER AS PER PILE CAP SCHEDULE
AS PER PLAN TO REINF. PLAN
WATER STOP
AS PER RELATED PILE CAP SCHEDULE

AS PER SPEC.
Ld
AS PER RELATED PILE CAP SCHEDULE

FOR REINF. REFER AS PER PILE CAP SCHEDULE


Ld AS PER PLAN TO REINF. PLAN

AS PER RELATED PILE CAP SCHEDULE


Ld
T12@300 RINGS
50MM PROTECTION
SCREED T12@300 RINGS
WATER PROOFING AS 50MM PROTECTION
6 PER PROJECT SPECT. SCREED
WATER PROOFING AS
75mm BLINDING 50MM HIGH STRENGTH PER PROJECT SPECT.
100

FLOWABLE EPOXY GROUT T12@300 RINGS


COMPACTED FILL
75mm BLINDING 50MM HIGH STRENGTH 50MM PROTECTION
100

95% PROCTOR TEST 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


FLOWABLE EPOXY GROUT SCREED
COMPACTED FILL
95% PROCTOR TEST WATER PROOFING AS AUTHORITY APPROVAL 0 17.08.2017 NS
PER PROJECT SPECT.
Purpose of Issue Rev. Date Appoved
75mm BLINDING 50MM HIGH STRENGTH

100
FLOWABLE EPOXY GROUT Client:
COMPACTED FILL
95% PROCTOR TEST

5 PILE REINFORCMENT AS PER THE PILING CONTRACTOR


COMPLYING WITH THE PROJECT SPECIFICATIONS MEYDAN L.L.C
PILE REINFORCMENT AS PER THE PILING CONTRACTOR P.O. Box 9305, Dubai , UAE.
COMPLYING WITH THE PROJECT SPECIFICATIONS T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
PILE REINFORCMENT AS PER THE PILING CONTRACTOR
COMPLYING WITH THE PROJECT SPECIFICATIONS

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

BASEMENT WALL SECTION 1 BASEMENT WALL SECTION 2 BASEMENT WALL SECTION 3


1 SCALE 1 : 25
2 SCALE 1 : 25
3 SCALE 1 : 25
Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

FOUNDATION DETAILS - 06

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 25 A1
08.06.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-00-S5106 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

AS PER PLAN
FOR REINF. REFER
AS PER SLAB REINF. AS PER PLAN
DUBAI MUNICIPALITY STAMP:
TO REINF. PLAN

SLAB THICK.
AS PER PLAN 350 AS PER SLAB REINF.

300
SLAB THICK.
11

50
300
T12@150 T16@150
T12@150 T12@150 50mm TH. FIXABLE FILLER BOARD

WATER LEVEL WATER LEVEL WATER LEVEL

WATER LEVEL T12@150


N
10 T16@150 KEY PLAN
T12@150

T12@150 T16@150

T16@150

350

T12@150
9
T12@150 T20@150
T20@150
T12@150 WATER STOPPER
AS PER SPEC. WATER STOPPER
T20@150
AS PER SPEC.
WATER STOPPER General Notes:
AS PER SPEC.
50mm TH. FIXABLE FILLER BOARD
1. DO NOT SCALE FROM THIS DRAWING.
T12@150 T12@150
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
AS PER PLAN 350

350
BY THE ENGINEER.

AS PER PLAN 350 AS PER PLAN 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

50
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

500
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

500
500
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

50MM PROTECTION
SCREED
AS PER FOUNDATION REINF. 50MM PROTECTION AS PER FOUNDATION REINF.
50MM PROTECTION WATER PROOFING AS
PER PROJECT SPECT. SCREED
SCREED
WATER PROOFING AS
WATER PROOFING AS AS PER FOUNDATION
7 75mm BLINDING PER PROJECT SPECT.
PER PROJECT SPECT. REINF.
COMPACTED FILL 75mm BLINDING
75mm BLINDING 95% PROCTOR TEST
COMPACTED FILL
COMPACTED FILL
95% PROCTOR TEST
95% PROCTOR TEST

SECTION 2-2
SECTION 1-1 2 SCALE 1 : 25 SECTION 3-3
1 SCALE 1 : 25
3 SCALE 1 : 25

350 AS PER SLAB REINF. AS PER PLAN 350 AS PER SLAB REINF.
AS PER PLAN AS PER RAMP 01 REINF. 0
100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS

SLAB THICK.

SLAB THICK.
AUTHORITY APPROVAL 0 17.08.2017 NS
300

Purpose of Issue Rev. Date Appoved


Client:
300

WATER PROOFING AS
PER PROJECT SPECT.
5
T12@150 T12@150 75mm BLINDING MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
50mm TH. FIXABLE FILLER BOARD VAR. T: +9714 3270000 F: +9714 3270007
WATER LEVEL WATER LEVEL E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

350

T12@150 T12@150
50mm TH. FIXABLE FILLER BOARD
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
T16@150 T16@150 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
WATER LEVEL T16@150 WATER LEVEL PROTECTION BOARD PO Box 54115 Dubai, UAE
T16@200 P: +971 4 3997758 F: +971 4 3997759
4 T12@150 SHOTCRETE
T20@150 Sub-Consultant:
WATER PROOFING
AS PER SPEC.
SECANT PILE WALL
(REFER TO SHORING DETAILS)

T12@150 T12@150
T12@150
T20@150 T20@150
WATER STOPPER WATER STOPPER
AS PER SPEC. WATER STOPPER Project Name:
AS PER SPEC. AS PER SPEC.
T20@150

3
DUBAI WATER CANAL
50mm TH. FIXABLE FILLER BOARD T16@150 T16@150 AS PER PLAN SAFA A
350 350
DUBAI-UAE
350

AS PER PLAN

Project Description:
500

500
MIXED USE DEVELOPMENT
500

(RETAIL & RESIDENTIAL)


PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
50MM PROTECTION 50MM PROTECTION Drawing Title:
AS PER SCREED SCREED
50MM PROTECTION FOUNDATION REINF. AS PER FOUNDATION AS PER
SCREED WATER PROOFING AS REINF. WATER PROOFING AS
FOUNDATION REINF.
PER PROJECT SPECT. PER PROJECT SPECT.
WATER PROOFING AS
PER PROJECT SPECT. 75mm BLINDING 75mm BLINDING
FOUNDATION DETAILS - 07
75mm BLINDING COMPACTED FILL COMPACTED FILL
95% PROCTOR TEST 95% PROCTOR TEST
COMPACTED FILL
95% PROCTOR TEST
Scale Drawn Checked Approved Size
SECTION 4-4 SECTION 5-5 SECTION 6-6 AA MA NS
1 4 SCALE 1 : 25
5 SCALE 1 : 25
6 SCALE 1 : 25
1 : 25
08.06.2017 24.08.2017 24.08.2017
A1

Drawing Number Rev.

14011603-01-00-S5107 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

AS PER PLAN 350 T12@150 T12@150 DUBAI MUNICIPALITY STAMP:


T12@150 T12@150
0.050 SSL VAR.

T12@150 T12@150
T12@150 T12@150

300

300
11
VAR. 0.050 SSL

VAR. AS PER RAMP REINF.


WATER PROOFING AS
PER PROJECT SPECT.

300

300
T12@150 T12@150
75mm BLINDING
400
400

SECTION 2-2 SECTION 3-3


2 3

300
SCALE 1 : 25
SCALE 1 : 25
T12 @150
2T16 300 2T16 N
10 350 T12 @150
AS PER PLAN T12@200 KEY PLAN
AS PER PLAN FOR REINF. REFER
WATER LEVEL TO REINF. PLAN

300
Ld AS PER PLAN

MAX. 400
T12@150
50mm TH. FIXABLE FILLER BOARD Ld
T16@150

PROTECTION BOARD
T16@200
SHOTCRETE
9 T20@150
WATER PROOFING
AS PER SPEC.
SECANT PILE WALL
(REFER TO SHORING DETAILS)
General Notes:
T20@150 50MM PROTECTION
T12@150 50MM PROTECTION SCREED 1. DO NOT SCALE FROM THIS DRAWING.
SCREED WATER PROOFING AS
WATER STOPPER 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
AS PER SPEC. WATER PROOFING AS PER PROJECT SPECT.
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
PER PROJECT SPECT.
75mm BLINDING BY THE ENGINEER.
T16 @150
T16 @150 75mm BLINDING
COMPACTED FILL 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
COMPACTED FILL 95% PROCTOR TEST SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 95% PROCTOR TEST AT SITE.
350
TYPICAL DETAIL FOR MECHANICAL TRENCH AT PILE CAP TYPICAL DETAIL FOR DRAIN PIT AT PILE CAPS

350
4 5
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
SCALE 1 : 25 SCALE 1 : 25 AND RELEVANT SECTIONS OF THE SPECIFICATION.

500
500 AS PER PLAN 500

FOR REINF. REFER FOR REINF. REFER


TO REINF. PLAN AS PER PLAN TO REINF. PLAN
7
50MM PROTECTION
SCREED

500
AS PER
WATER PROOFING AS
FOUNDATION REINF.
PER PROJECT SPECT.

1100
75mm BLINDING

SECTION 1-1 COMPACTED FILL


95% PROCTOR TEST
1 SCALE 1 : 25 T20@150 T20@150 T20@150
50MM PROTECTION 50MM PROTECTION
SCREED T20@150 T20@150
SCREED
WATER PROOFING AS WATER PROOFING AS
WATER PROOFING
6 AS PER PLAN PER PROJECT SPECT. PER PROJECT SPECT.
AS PER SPEC.

500
2T16 2T16 75mm BLINDING PROTECTION BOARD 75mm BLINDING
FOR REINF. REFER FOR REINF. REFER
AS PER PLAN

TO REINF. PLAN AS PER PLAN TO REINF. PLAN COMPACTED FILL COMPACTED FILL
95% PROCTOR TEST BLOCK WORK 200mm 95% PROCTOR TEST
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 17.08.2017 NS
500

250 50 AS PER PLAN 50 250


Purpose of Issue Rev. Date Appoved
50MM PROTECTION Client:

250
SCREED
WATER PROOFING AS T16@100
TYPICAL DETAIL FOR ESCALATOR PIT

50
PER PROJECT SPECT.

5 7 SCALE 1 : 25 75mm BLINDING


T12@100
50MM PROTECTION COMPACTED FILL MEYDAN L.L.C
95% PROCTOR TEST P.O. Box 9305, Dubai , UAE.
SCREED T: +9714 3270000 F: +9714 3270007
WATER PROOFING AS FOR REINF. REFER E: info@dubairacingclub.com W: www.dubairacingclub.com
PER PROJECT SPECT. TO REINF. PLAN

AS PER PLAN
Principal Consultant:
75mm BLINDING
500 2000 500
COMPACTED FILL
95% PROCTOR TEST FOR REINF. REFER FOR REINF. REFER 50mm TH. FIXABLE FILLER BOARD
TO REINF. PLAN AS PER PLAN TO REINF. PLAN
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com

TYPICAL DETAIL FOR DRAIN PIT / TRENCH AT RAFT 500 Hassanicor Building, 6th Floor, Al Barsha 1

6
PO Box 54115 Dubai, UAE
500

P: +971 4 3997758 F: +971 4 3997759


4 SCALE 1 : 25

50
Sub-Consultant:
WALL

250
THICK.

T16@150 T16@150
TYPICAL DETAIL FOR INTERIOR COLUMN IN WATER TANKS
FOR REINF. REFER
FOR REINF. REFER 50MM PROTECTION T16@150 T16@150 50MM PROTECTION
TO REINF. PLAN
TO CORE WALL DETAILS SCREED
WATER PROOFING AS
SCREED
WATER PROOFING AS
10 SCALE 1 : 25
AS PER PLAN PER PROJECT SPECT. PER PROJECT SPECT. Project Name:
75mm BLINDING 75mm BLINDING
DUBAI WATER CANAL
3000

COMPACTED FILL COMPACTED FILL


3 95% PROCTOR TEST 95% PROCTOR TEST
Ld SAFA A
250 50 AS PER PLAN 50 250
DUBAI-UAE

250
Project Description:
T16@100

50
600
MIXED USE DEVELOPMENT
T12@100 (RETAIL & RESIDENTIAL)
WATER PROOFING
AS PER SPEC.
PLOT 01 / 3435338
2 WATER PROOFING
AS PER SPEC.
T16@150 PROTECTION BOARD BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)

AS PER PLAN
PROTECTION BOARD BLOCK WORK 200mm
Drawing Title:
600

BLOCK WORK 200mm 50mm TH. FIXABLE FILLER BOARD


500

FOUNDATION DETAILS - 08
50

Scale Drawn Checked Approved Size


250

50MM PROTECTION AA MA NS
1 SCREED 1 : 25 A1
TYPICAL SECTION FOR SUMP PITS WATER PROOFING AS 08.06.2017 24.08.2017 24.08.2017

TYPICAL SECTION IN DRAIN PIT IN ELEVATOR RAFT 9 PER PROJECT SPECT. TYPICAL DETAIL FOR EXTERIOR COLUMN ATTACHED TO WATER TANKS
8
SCALE 1 : 25
75mm BLINDING 11 Drawing Number Rev.

SCALE 1 : 25 COMPACTED FILL


SCALE 1 : 25
14011603-01-00-S5108 0
95% PROCTOR TEST
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

FILLER MATERIAL AS PER SPEC.


200 VAR. 200
T10@200 300 150
T10@200
DUBAI MUNICIPALITY STAMP:

150
150

300
STRUCTURAL WALL
11
T12@150 T12@150
AS PER SITE LEVELS AS PER SITE LEVELS
T10@200 T10@200 200 VAR. 200
50MM PROTECTION

AS PER ARCH.
MAX. 1500 mm
SELF ADHESIVE 50MM PROTECTION SCREED
MEMBRANE AS PER SPEC. WATER PROOFING SELF ADHESIVE MEMBRANE AS PER SPEC. SCREED
WATER PROOFING AS
AS PER SPEC. T10@150 T10@150 WATER PROOFING AS
AS PER SITE LEVELS AS PER SITE LEVELS PER PROJECT SPECT.
T10@200 PER PROJECT SPECT.
PROTECTION BOARD

MAX. 400
FOR REINF. REFER 75mm BLINDING
TO REINF. PLAN T10@200 75mm BLINDING
BLOCK WORK 200mm WATER PROOFING COMPACTED FILL
AS PER SPEC. PLANTERS COMPACTED FILL 95% PROCTOR TEST
FOR REINF. REFER 95% PROCTOR TEST
PROTECTION BOARD
TO REINF. PLAN N
KEY PLAN
10
S.O.G SLAB 150 UNDER WALK WAYS

300
PLANTERS BLOCK WORK 200mm

3 TYPICAL DETAIL S.O.G SLAB 150 UNDER WALK WAYS


SCALE 1 : 25 5 SCALE 1 : 25
ADJACENT TO STRUCTURAL ELEMENTS
300

FILLER MATERIAL AS PER SPEC.


50MM PROTECTION
SCREED T10@200
T10@200 300 100
WATER PROOFING AS
PER PROJECT SPECT.
50MM PROTECTION

200
300
SCREED

200
75mm BLINDING
WATER PROOFING AS STRUCTURAL WALL
PER PROJECT SPECT. COMPACTED FILL
9 95% PROCTOR TEST
75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST
50MM PROTECTION
50MM PROTECTION SCREED General Notes:
SCREED WATER PROOFING AS
TYPICAL SECTION IN PLANTER - 1 TYPICAL SECTION IN PLANTER - 2 WATER PROOFING AS PER PROJECT SPECT. 1. DO NOT SCALE FROM THIS DRAWING.
1 SCALE 1 : 25
2 SCALE 1 : 25
PER PROJECT SPECT.
75mm BLINDING 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
75mm BLINDING NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
COMPACTED FILL BY THE ENGINEER.
COMPACTED FILL 95% PROCTOR TEST
95% PROCTOR TEST 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8
S.O.G SLAB 200 UNDER VEHICLES WAYS TYPICAL DETAIL S.O.G SLAB 200 UNDER VEHICLES WAYS
AT SITE.

4 6 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


SCALE 1 : 25 SCALE 1 : 25
ADJACENT TO STRUCTURAL ELEMENTS ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

300 600 300 50


250 250

WATER LEVEL WATER LEVEL


7
T10@200 AS PER SITE LEVELS T10@200 AS PER SITE LEVELS
T12@200 T12@150 50mm TH. FIXABLE FILLER BOARD 50mm TH. FIXABLE FILLER BOARD

UP TO 1400mm
UP TO 700mm

WATER STOP AS T16@150


PER SPAC.
FOR REINF. REFER TO T16@150 FOR REINF. REFER TO
REINFORCEMENT PLAN REINFORCEMENT PLAN
AS PER SITE LEVELS AS PER SITE LEVELS

300

300

50 300
WATER PROOFING WATER PROOFING
AS PER SPEC. AS PER SPEC.
400

400

PROTECTION BOARD PROTECTION BOARD


BLOCK WORK 200mm BLOCK WORK 200mm

500
6

300 250 300 400 250 400


AS PER 0
50MM PROTECTION 50MM PROTECTION FOUNDATION REINF.
100% CONSTRUCTION DOCUMENTS FOR TENDER 24.08.2017 NS
AS PER
SCREED FOUNDATION REINF. SCREED AUTHORITY APPROVAL 0 17.08.2017 NS
WATER PROOFING AS WATER PROOFING AS
PER PROJECT SPECT. PER PROJECT SPECT. 50MM PROTECTION Purpose of Issue Rev. Date Appoved
SCREED
75mm BLINDING 75mm BLINDING WATER PROOFING AS Client:
PER PROJECT SPECT.
COMPACTED FILL COMPACTED FILL
95% PROCTOR TEST 95% PROCTOR TEST 75mm BLINDING

5 COMPACTED FILL
95% PROCTOR TEST
MEYDAN L.L.C
SECTION 1 IN RW SECTION 2 IN RW
7 8
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
SCALE 1 : 25 SCALE 1 : 25 TYPICAL DETAIL FOR DRAIN PIT IN DOMESTIC TANK E: info@dubairacingclub.com W: www.dubairacingclub.com

9 SCALE 1 : 25
Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
200 600 200 Sub-Consultant:
200 600 200
INSOLUTION LAYER
INSOLUTION LAYER AS PER SITE LEVELS AS PER SPEC. AS PER SITE LEVELS WATER STOPPER
AS PER SITE LEVELS AS PER SITE LEVELS
AS PER SPEC. AS PER SPEC.
AS PER MECH. DETAILS

AS PER RAFT
REINFORCEMENT
T12@150 T12@150
950

370
T12@150 300 600
T12@150 Project Name:

T16@150
DUBAI WATER CANAL

250
SLAB THICK.
WATER PROOFING WATER PROOFING T16@150

300
3 AS PER SPEC. T12@150 AS PER SPEC. T12@150 T16@150
T16@150

500
PROTECTION BOARD PROTECTION BOARD SAFA A
200

300

THICK.
SLAB
BLOCK WORK 200mm BLOCK WORK 200mm
DUBAI-UAE

Project Description:

50MM PROTECTION 50MM PROTECTION 50MM PROTECTION


MIXED USE DEVELOPMENT
50MM PROTECTION
SCREED SCREED SCREED
WATER PROOFING AS WATER PROOFING AS
SCREED
WATER PROOFING AS
(RETAIL & RESIDENTIAL)
WATER PROOFING AS
PER PROJECT SPECT. PER PROJECT SPECT.
PER PROJECT SPECT.
PER PROJECT SPECT. T20@150 PLOT 01 / 3435338
75mm BLINDING 75mm BLINDING 75mm BLINDING
2 75mm BLINDING BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
COMPACTED FILL COMPACTED FILL COMPACTED FILL
COMPACTED FILL
95% PROCTOR TEST 95% PROCTOR TEST 95% PROCTOR TEST
95% PROCTOR TEST Drawing Title:

TYPICAL DETAIL FOR MECHANICAL MANHOLE ON GRADE TYPICAL DETAIL FOR CABLE TRENCH ON GRADE TYPICAL DETAIL FOR DRAIN PIT IN WATER TANK TYPICAL SECTION IN EARTH PIT FOUNDATION DETAILS - 09
10 SCALE 1 : 25
11 SCALE 1 : 25
12 SCALE 1 : 25
13 SCALE 1 : 25

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 25 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-00-S5109 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

02

SLAB
50 N@S 50
SLAB

S
N
10 04 KEY PLAN

T10 @S LINKS

50 N@S 50
S DROP PANEL

50
01 01

M@S
S
L
9
T10 @S LINKS

50
Rows x S
General Notes:

50
Rows x S
1. DO NOT SCALE FROM THIS DRAWING.

03 03 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

M@S
S
L
BY THE ENGINEER.

3000
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

50
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
B Rows x S ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

Rows x S
02

7 2800
B
PUNCHING SHEAR DETAILS TYPE A
A
NTS
04
SLAB RENIF. AS PER SCHEDULE
LINKS
THICK
SLAB

6
50 B 50
T10@S T10@S

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


R.C. COLUMN AUTHORITY APPROVAL 0 17.08.2017 NS
PUNCHING SHEAR DETAILS TYPE B Purpose of Issue Rev. Date Appoved
B Client:
NTS
SEC. (01-01)
01
5 NTS
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
AS PER SCHEDULE SLAB RENIF. SLAB RENIF. AS PER SCHEDULE SLAB RENIF. E: info@dubairacingclub.com W: www.dubairacingclub.com
SLAB RENIF.
LINKS LINKS Principal Consultant:

THICK
SLAB
THICK
SLAB

THICK
D.P
50 L 50 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
T10@S T10@S www.ae-7.com
AS PER D.P REINF. 50 B 50 Hassanicor Building, 6th Floor, Al Barsha 1
T10@S T10@S PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 R.C. COLUMN
Sub-Consultant:
R.C. COLUMN

SEC. (02-02)
02 SEC. (03-03)
NTS 03
NTS
Project Name:

3 SLAB RENIF. SLAB RENIF. AS PER SCHEDULE SLAB RENIF.


DUBAI WATER CANAL
LINKS SAFA A
THICK
SLAB

DUBAI-UAE
SCHEDULE OF PUNCHING SHEAR

THICK
D.P
Project Description:
DETAIL COLUMN DIMENSION NO. OF LINKS NO. OF SPACING DETAIL
AS PER D.P REINF. 50 L 50 MIXED USE DEVELOPMENT
MARK B (mm) L (mm) N M ROWS (S) TYPE T10@S T10@S
(RETAIL & RESIDENTIAL)
P.S.1 300 1200 3 15 8 75 B
R.C. COLUMN PLOT 01 / 3435338
2 P.S.2 400 1200 4 15 6 75 A BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
P.S.3 300 1200 3 15 6 75 A Drawing Title:

P.S.4 250 1200 2 15 6 75 A


SEC. (04-04)
P.S.5 400 1200 4 15 5 75 A 04 SLAB DETAILS - 01
400 1200 4 2 75 A
NTS
P.S.6 15

P.S.7 400 1200 4 15 7 75 A


Scale Drawn Checked Approved Size
300 1300 3 17 6 75 A AA MA NS
1 P.S.8 1 : 25 A1
08.06.2017 24.08.2017 24.08.2017
P.S.9 400 1200 4 15 3 75 A
Drawing Number Rev.

14011603-01-00-S5301 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


200 50 200

DIM

T
T
DIM DIM DIM 3T20 T&B 3T20 T&B 3T20 T&B FOR REINF. REFER FOR REINF. REFER
11 TO REINF. PLAN TO REINF. PLAN FOR REINF. REFER
TO REINF. PLAN
T10@200 T10@200
-0.400 SSL -0.400 SSL

3T20 T&B

3T20 T&B
T T T10@200 T10@200
AS PER PLAN

DIM

DIM
FOR REINF. REFER

THICK.
T

SLAB
TO REINF. PLAN
DIM
T 3T20 T&B 3T20 T&B 3T20 T&B AS PER PLAN

DIM

T
MASTIC MATERIAL AS PER SPEC. DETAILS AS PER BEAM SCHEDULE

THICK.
SLAB
N
10 50mm EXPANSION JOINT KEY PLAN

TYPICAL DETAIL FOR REIN. AROUND OPENINGS IN SLABS TYPICAL DETAIL FOR EXPANSION JOINT TYPICAL DETAIL FOR BEAM BETWEEN SLABS WITH DIFFERENT LEVELS
T1 SCALE 1 : 25
T2 SCALE 1 : 25
T3 SCALE 1 : 25

200 300 200

AS PER ARCH.
FOR REINF. REFER
T10@200
TO REINF. PLAN
T10@200

300
200 300 200
9 AS PER ARCH 300 FOR REINF. REFER
-0.200 SSL T10@200
TO REINF. PLAN
2T10

200
T10@200

300
200

-0.400 SSL
THICK.
SLAB

General Notes:

THICK.
SLAB
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


FOR REINF. REFER NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
TO REINF. PLAN FOR REINF. REFER BY THE ENGINEER.
TO REINF. PLAN
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 TYPICAL DETAIL FOR UPSTAND UNDER CURTAIN WALLS TYPICAL SECTION IN TRENCH IN ARCHITECTURAL FINISH SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

T4 T5
AT SITE.

SCALE 1 : 25 SCALE 1 : 25
TYPICAL SECTION IN TRENCH EMBEDDED IN STRUCTURAL SLAB
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
T6 SCALE 1 : 25
AND RELEVANT SECTIONS OF THE SPECIFICATION.

300 600 300 M25-G8.8 200


FILLET WELD
INSOLUTION LAYER
AS PER SPEC. PLATE
FOR REINF. REFER FOR REINF. REFER
TO REINF. PLAN TO REINF. PLAN

AS PER ARCH.
T10@200

MAX 800
7 AS PER SITE LEVELS AS PER SITE LEVELS
T12@200
RING STIRRUPS PT SLAB
THICK.

THICK.
SLAB

SLAB

T12@150 STEEL REINFORCEMENT (DOWELS)

CONCRETE PEDESTAL
T12@150

THICK
SLAB
T12@150 Ld
300

TYPICAL DETAIL FOR ROOF PARAPETS


T11 SCALE 1 : 25 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

TYPICAL DETAIL FOR MECHANICAL MANHOLE ON SLAB AUTHORITY APPROVAL 0 17.08.2017 NS


T7 SCALE 1 : 25 TYPICAL DETAIL FOR PEDESTAL
200 Purpose of Issue Rev. Date Appoved

T8 SCALE 1 : 25 T10@200
Client:
M25-G8.8 AS PER LANDSCAPE

AS PER ARCH.
T10@200
PLATE T10@200 T12@150mm
T12@200 (RING STIRRUPS) T12@200

200
5 4T12 (DOWELS)
WATER TANKS
CONCRETE PEDESTAL
T8@150/STEP
MEYDAN L.L.C

310
T8/STEP P.O. Box 9305, Dubai , UAE.
AS PER PLAN T: +9714 3270000 F: +9714 3270007
T12@150mm
E: info@dubairacingclub.com W: www.dubairacingclub.com
T12@150mm
THICK

Principal Consultant:
SLAB

200 VARIES 200

200
50MM PROTECTION
SCREED T10@200
400 600 400 600 400 600 400 600 400 600 WATER PROOFING AS T10@200 AS PER LANDSCAPE
8T12 PT SLAB PER PROJECT SPECT.
EPOXY PAINTED SURFACE abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
+0.60m FROM SSL

200
75mm BLINDING www.ae-7.com
PT SLAB T12@200
Hassanicor Building, 6th Floor, Al Barsha 1
COMPACTED FILL PO Box 54115 Dubai, UAE
95% PROCTOR TEST P: +971 4 3997758 F: +971 4 3997759
4
TYPICAL DETAIL FOR BMU UPSTAND
600

Sub-Consultant:

+21.400 SSL
T10 SCALE 1 : 25
50MM PROTECTION
SCREED
TYPICAL DETAIL STAIR ON GRADE
THICK
SLAB

WATER PROOFING AS
T12 SCALE 1 : 25
PER PROJECT SPECT.

75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST Project Name:

TYPICAL WATERTANK UPSTANDS @ ROOF DETAIL DUBAI WATER CANAL


3 T9 SCALE 1 : 25
LPG TANK SAFA A
500 US GALLONS CAPACITY
DUBAI-UAE

Project Description:
EPOXY PAINTED SURFACE

200 200
2000 MIXED USE DEVELOPMENT
AS PER. ISOLATION/ABSORPTION MATERIAL PADS
200 200
LANDSCAPE. AS PER MECHANICAL SPECIFICATION
200 60 300 VARIES 300 60 200
(RETAIL & RESIDENTIAL)
500 150 700 150 500
40 (ACCORDING TO MECH. EQUIPMENT SELECTION) 40 PLOT 01 / 3435338

VARIES
SELF ADHESIVE CONCRETE UPSTAND / PLINTHS WITH
VARIES

T12@200
MEMBRANE AS PER SPEC. NECESSARY REINFORCEMENT
2 T12@200 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
20X30 GROOVE WITH SEALANT 150 200 VARIES 200 150 T12@200 ISOLATION/ABSORPTION MATERIAL PADS
T10@200 PLANTER T10@200 T12@200
(ACCORDING TO MECH. EQUIPMENT SELECTION) T12@200 AS PER MECHANICAL SPECIFICATION
T12@200 T12@200 3T12 3T12 T12@200 Drawing Title:
PT SLAB
600

T12@200 T12@200
T12@200 T12@200 T12@200
LANDSCAPE.

150 50 150

T12@200 T12@200
FOR REINF. REFER
AS PER

TO REINF. PLAN +21.400 SSL

+5.500 SSL
+21.400 SSL
SLAB DETAILS - 02
THICK
SLAB
350

Scale Drawn Checked Approved Size


PT SLAB AA NS
MA
1 1 : 25 A1
20.07.2017 24.08.2017 24.08.2017

TYPICAL SECTION IN PLANTER AT LEVEL 01 TYPICAL DETAIL FOR LPG TANK RC SUPPORT TYPICAL DETAIL UNDER MECHANICAL EQUIPMENTS TYPICAL DETAIL FOR CHILLERS
T13 T14 T15 T16 Drawing Number Rev.

SCALE 1 : 25 SCALE 1 : 25 SCALE 1 : 25 SCALE 1 : 25


14011603-01-00-S5302 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

200 2200 200


DUBAI MUNICIPALITY STAMP:
FFL AS PER ARCH

T12@200 200 AS PER ARCH. 200


11 VAR.

T10@200
T12@200
FOR REINF. REFER FOR REINF. REFER
-0.100 SSL TO REINF. PLAN TO REINF. PLAN -0.100 SSL

AS PER ARCH.
MAX. 1400 mm
SELF ADHESIVE
FOR REINF. REFER MEMBRANE AS PER SPEC.
TO REINF. PLAN
-0.200 SSL FOR REINF. REFER PLANTER T10@200
TO REINF. PLAN
T12@200
N
10 -0.400 SSL KEY PLAN

AS PER ARCH.
MAX. 1050 mm
300
FOR REINF. REFER
TO REINF. PLAN

350
WATER PROOFING AS PER PLAN
AS PER SPEC. 50MM PROTECTION BEAM AS PER SCHEDULE
SCREED
PROTECTION BOARD
WATER PROOFING AS FOR REINF. REFER

VAR
PER PROJECT SPECT. WATER TANK DETAILS
BLOCK WORK 200mm
BEAM AS PER SCHEDULE 75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST
BASEMENT WALL

SECTION 2-2 SECTION 3-3


9
2 SCALE 1 : 25
3 SCALE 1 : 25

SECTION 1-1 General Notes:


1 SCALE 1 : 25 200 1050 300 500 200 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
SELF ADHESIVE MEMBRANE AS PER SPEC. BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 885 200 4515 300 50 200

AS PER ARCH.
MAX. 1400 mm
AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


FOR REINF. REFER FOR REINF. REFER ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
MAX. 400mm

MAX. 400mm
TO REINF. PLAN TO REINF. PLAN AND RELEVANT SECTIONS OF THE SPECIFICATION.
T10@200 T10@200 FILLER MATERIAL AS PER SPEC.
MASTIC MATERIAL AS PER SPEC. T10@200

AS PER ARCH.
MAX. 1050 mm
-0.400 SSL T12@200 T12@200 -0.400 SSL
T10@200 T12@200
300 T20@150

AS PER LANDSCAPE
350

T16@150

150
MAX. 1100mm
T10@200
0.000 SSL PLANTER
T12@200
PLANTER
7 DETAILS AS PER BEAM SCHEDULE

300
T12@150

500
50MM PROTECTION
SELF ADHESIVE MEMBRANE AS PER SPEC. SCREED
50mm EXPANSION JOINT
+5.925 SSL -1.500 SSL WATER PROOFING AS
BEAM OR WALL PER PROJECT SPECT. PROTECTION BOARD T20@150
DETAILS AS PER BEAM SCHEDULE
75mm BLINDING T16@150
SHOTCRETE AS PER BASEMENT WALL
COMPACTED FILL
95% PROCTOR TEST WATER PROOFING RENF.
T16 @150
AS PER SPEC.
T16 @150 AS PER BASEMENT WALL
SECANT PILE WALL / KING POST
BEAM AS PER SCHEDULE (REFER TO SHORING DETAILS) RENF.

6 WATER PROOFING AS

SECTION 4-4 SECTION 5-5


PER PROJECT SPECT.

4 SCALE 1 : 25
5 SCALE 1 : 25
BLINDING

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
200 AS PER ARCH. 200 300 1500 300
Client:

FOR REINF. REFER FOR REINF. REFER


TO REINF. PLAN TO REINF. PLAN
5 +0.400 SSL INSOLUTION LAYER +0.400 SSL
T12 @200 AS PER SPEC. MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
AS PER ARCH.
MAX. 1800 mm

T12 @150

THICK.

THICK.
T: +9714 3270000 F: +9714 3270007

SLAB

SLAB
LD LD E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

1500
PLANTER
AS PER ARCH.
MAX. 1100 mm

T10 @200 T12@200 T12@200


T12 @200 T16@200 T16@200
SELF ADHESIVE MEMBRANE AS PER SPEC.
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
-0.400 SSL PLANTER www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
T12@200 P: +971 4 3997758 F: +971 4 3997759
350

4
Sub-Consultant:

300
AS PER SLAB
REINFORCEMENT

SECTION 6-6 SECTION 7-7


6 SCALE 1 : 25
7 SCALE 1 : 25
50MM PROTECTION
SCREED
Project Name:
WATER PROOFING AS

3
PER PROJECT SPECT. DUBAI WATER CANAL
75mm BLINDING SAFA A
FFL AS PER ARCH 200 200 FFL AS PER ARCH COMPACTED FILL
95% PROCTOR TEST DUBAI-UAE
MAX 400

T12@200 T12@200
T10@200 T10@200 FILLER MATERIAL AS PER SPEC.
-0.400 SSL -0.400 SSL Project Description:
T20@150
350 30 300 100 T12@150 MIXED USE DEVELOPMENT
THICK

THICK
SLAB

SLAB

SELF ADHESIVE MEMBRANE AS PER SPEC. (RETAIL & RESIDENTIAL)

AS PER LANSCAPE

200
AS PER LANDSCAPE

AS PER LANDSCAPE

300
PLOT 01 / 3435338

MAX. 1400mm
MAX. 1100mm

MAX. 1100mm
Ld

Ld

RC SLAB RC SLAB
2 300
FOR REINF. REFER
TO REINF. PLAN
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
AS PER ARCH.

AS PER PLAN
3T10 Drawing Title:
SLAB THICK.

T10@200 -0.400 SSL


BEAM AS PER SCHEDULE BEAM AS PER SCHEDULE PROTECTION BOARD
-1.500 SSL
SHOTCRETE
SLAB DETAILS - 03
350

WATER PROOFING
AS PER SPEC.
T16 @150 SECANT PILE WALL
FOR REINF. REFER (REFER TO SHORING DETAILS)
T16 @150 TO REINF. PLAN
BEAM AS PER SCHEDULE Scale Drawn Checked Approved Size
AS PER PLAN AA MA NS
1 1 : 25 A1
350
20.07.2017 24.08.2017 24.08.2017
SECTION 8-8 SECTION 9-9 SECTION 10-10
8 9 10
Drawing Number Rev.
SCALE 1 : 25
SCALE 1 : 25 SCALE 1 : 25 14011603-01-00-S5303 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


PT SLAB PT SLAB

11 +5.900 SSL
+5.925 SSL +5.925 SSL LD
THICK
SLAB

280

300

600
PT SLAB
5.925 SSL
BEAM AS PER SCHEDULE
FOR REINF. REFER

1425
TO REINF. PLAN 5.475 SSL +5.925 SSL
T12@150 +5.855 SSL

350
BLOCK WORK
BEAM AS PER SCHEDULE T12@150
N

350

280
KEY PLAN

350
+4.700 SSL
10
T12@200
+4.500 SSL T16@150

600
200
BEAM AS PER SCHEDULE BEAM AS PER SCHEDULE
BEAM AS PER SCHEDULE
T12@200
200 400 2700
300 2500 200

SECTION 2-2 SECTION 3-3 SECTION 4-4


SECTION 1-1 2 SCALE 1 : 25
3 SCALE 1 : 25
4 SCALE 1 : 25
9
1 SCALE 1 : 25

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

200 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
T10@200 BY THE ENGINEER.
AS PER PLAN 2T10
+5.925 SSL P.T SLAB +5.925 SSL P.T SLAB 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

AS PER ARCH.
T10@200

75
P.T SLAB SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

MAX 800
+5.925 SSL
8 +5.865 SSL T12@200 AT SITE.
P.T SLAB PT SLAB

280

300

35
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

280
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
+17.400 SSL AND RELEVANT SECTIONS OF THE SPECIFICATION.

500

THICK
SLAB
P.T SLAB BEAM AS PER SCHEDULE
200 +5.925 SSL 200
AS PER PLAN BEAM AS PER SCHEDULE BEAM AS PER SCHEDULE
P.T SLAB
35

200 200 BEAM AS PER SCHEDULE


BLOCK WORK
280

AS PER
BLOCK WORK

ARCH.
T12@200 T12@150
280

BEAM AS PER SCHEDULE


+4.700 SSL T16@150 +16.675 SSL T12@200
600

+4.700 SSL
7

250
BEAM AS PER SCHEDULE AS PER PLAN
BEAM AS PER SCHEDULE
T12@150
BEAM AS PER SCHEDULE

200 BEAM AS PER SCHEDULE

200

SECTION 5-5 SECTION 8-8


5 8
SCALE 1 : 25 SECTION 6-6 SECTION 7-7 SCALE 1 : 25
6 SCALE 1 : 25
7 SCALE 1 : 25
6 200
AS PER PLAN
LESS 200
THAN 200mm

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

AS PER ARCH.
T10@200

AS PER ARCH.
MAX 800
T10@200 0
T12@200 AUTHORITY APPROVAL 17.08.2017 NS
AS PER ARCH.

T10@200
PT SLAB T12@200
MAX 800

T12@200
PT SLAB Purpose of Issue Rev. Date Appoved
PT SLAB
Client:
+17.400 SSL
+17.400 SSL
+17.400 SSL
THICK
SLAB

THICK
SLAB
THICK

5 200
SLAB

200
200 MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.

AS PER
ARCH.
T12@200 T12@150 T: +9714 3270000 F: +9714 3270007
BEAM AS PER SCHEDULE

AS PER
ARCH.
T16@150 +16.675 SSL T12@200 T12@200 T12@150 E: info@dubairacingclub.com W: www.dubairacingclub.com
AS PER
ARCH.

T12@200 T12@150 BEAM AS PER SCHEDULE


BEAM AS PER SCHEDULE T16@150 +16.675 SSL T12@200
T16@150 +16.675 SSL T12@200 Principal Consultant:

250
T12@150
350 1000-1500 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
T12@150
1000-1500 T12@150 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
1000-1500 PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
SECTION 9-9 SECTION 10-10 SECTION 11-11
9 10 11
Sub-Consultant:
SCALE 1 : 25 SCALE 1 : 25 SCALE 1 : 25

300
300

FOR REINF. REFER FOR REINF. REFER


TO REINF. PLAN T12@200 TO REINF. PLAN
500

500
200 Project Name:
T12@200
AS PER PLAN AS PER PLAN

3
DUBAI WATER CANAL
THICK

THICK
SLAB

SLAB
SAFA A
AS PER ARCH.

T10@200

Ld
MAX 800

T12@200 DUBAI-UAE
PT SLAB PT SLAB PT SLAB

AS PER SLAB Project Description:


AS PER PLAN AS PER PLAN REINFORCEMENT
+17.400 SSL
MIXED USE DEVELOPMENT
THICK
SLAB

THICK

+0.400 SSL
SLAB

(RETAIL & RESIDENTIAL)


THICK
SLAB

200 AS PER SLAB


PLOT 01 / 3435338

400
T10@200 REINFORCEMENT
FOR REINF. REFER
2 BEAM AS PER SCHEDULE BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
AS PER
ARCH.

T12@200 T12@150 TO WALL REINF. DETAILS -0.100 SSL


BEAM AS PER SCHEDULE
T16@150 +16.675 SSL T12@200
FOR REINF. REFER Drawing Title:
TO WALL REINF. DETAILS

350
600
SLAB DETAILS - 04

150
T12@150

400 550 1000-1500 200 800


BEAM AS PER SCHEDULE

SECTION 12-12 SECTION 13-13 SECTION 14-14 SECTION 15-15 Scale Drawn Checked Approved Size

1 12 SCALE 1 : 25
13 SCALE 1 : 25
14 SCALE 1 : 25
15 SCALE 1 : 25 1 : 25
AA MA NS
A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-00-S5304 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:


T10@200
5T10

11
Ld AS PER PLAN AS PER PLAN
P.T SLAB P.T SLAB 200

35

SLAB THICK
280
525

BEAM AS PER SCHEDULE


T10@200
+5.300 SSL

800
T10@200

400 200
BEAM AS PER SCHEDULE +17.400 SSL T10@200 T10@200
BLOCK WORK 4T10

SLAB THICK
6T10 N
10 +4.700 SSL AS PER PLAN P.T SLAB KEY PLAN
AS PER PLAN P.T SLAB Ld
AS PER PLAN

300
AS PER PLAN
P.T SLAB

580
525

SLAB THICK
280
300

300

350
BEAM AS PER SCHEDULE
BEAM AS PER SCHEDULE
200
200 P.T SLAB
200 200 200

SECTION 1-1 SECTION 2-2 SECTION 3-3 SECTION 4-4 SECTION 5-5 SECTION 6-6
9
1 SCALE 1 : 25
2 SCALE 1 : 25
3 SCALE 1 : 25
4 SCALE 1 : 25
5 SCALE 1 : 25
6 SCALE 1 : 25

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
200 BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

T10@200 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
800

T10@200
AND RELEVANT SECTIONS OF THE SPECIFICATION.
200
P.T SLAB
+17.400 SSL +17.400 SSL
SLAB THICK

T10@200
350

+5.925 SSL P.T SLAB

800
T10@200

640
FOR REINF. REFER

280
T10@200 TO REINF. PLAN BEAM AS PER SCHEDULE
P.T SLAB
975

+21.400 SSL AS PER PLAN


7 T10@200
AS PER PLAN
625

BEAM AS PER SCHEDULE BEAM AS PER SCHEDULE

260
260
330
T10@200
200

350
BEAM AS PER SCHEDULE

70
2T10

70
400 500 200 P.T SLAB P.T SLAB 200 200
AS PER PLAN

SECTION 7-7 SECTION 8-8 SECTION 9-9 SECTION 10-10 SECTION 11-11
7 SCALE 1 : 25
8 SCALE 1 : 25
9 SCALE 1 : 25
10 SCALE 1 : 25
11 SCALE 1 : 25

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
VAR. Purpose of Issue Rev. Date Appoved
5000 MAX.
Client:

200

UB 203x133x25
5
T10@200 FOR REINF. REFER MEYDAN L.L.C
500 TO REINF. PLAN
500

T10@200 P.O. Box 9305, Dubai , UAE.


T: +9714 3270000 F: +9714 3270007
AS PER PLAN E: info@dubairacingclub.com W: www.dubairacingclub.com
AS PER PLAN P.T SLAB

TAPERED SECTION UC 356x406x467


Principal Consultant:
200

ENDING BY 150mm DEPTH


Ld
300
640

VAR.

UB 203x133x25 @1000

UB 203x133x25 @1000

UB 203x133x25 @1000

UB 203x133x25 @1000

UB 203x133x25
200
+21.400 SSL abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
T10@150 www.ae-7.com
WALL AS PER SCHEDULE
Hassanicor Building, 6th Floor, Al Barsha 1
600
260

PO Box 54115 Dubai, UAE


T10@150 P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:
P.T SLAB
200
BEAM AS PER SCHEDULE 300 130mm.STEEL DECK
STEEL COLUMN STEEL COLUMN
VAR. UC 356x406x287
+6.000 MAX. UC 356x406x287

SECTION 12-12 SECTION 13-13 SECTION 14-14


12 SCALE 1 : 25
13 SCALE 1 : 25
14 SCALE 1 : 25
TAPERED SECTION UC 356x406x467
ENDING BY 150mm DEPTH
TAPERED SECTION
UC 356x406x467
5000 MAX.

Project Name:
VAR.

ENDING BY
150mm DEPTH

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

TAPERED SECTION UC 356x406x467


MIXED USE DEVELOPMENT

ENDING BY 150mm DEPTH


UB 203x133x25 @1000

UB 203x133x25 @1000

UB 203x133x25 @1000

UB 203x133x25 @1000
T10@200 T10@200

UB 203x133x25
4T10 4T10
(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
360

2 AS PER PLAN
AS PER PLAN
580
600

Drawing Title:
300

220

200 P.T SLAB


200 P.T SLAB
SLAB DETAILS - 05
SECTION 15-15 SECTION 16-16 UB 203x133x25

15 SCALE 1 : 25
16 SCALE 1 : 25 Scale Drawn Checked Approved Size
AA MA NS
1 PLAZA CANOPY 1 : 25 A1
17 SCALE 1 : 25
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.
NOTE: STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, ETC…)
SHOWN IN DRAWINGS FOR INDICATIVE ONLY TO BE DESIGNED AND VERIFIED BY THE 14011603-01-00-S5305 0
STRUCTURAL STEEL CONTRACTOR AND SUBMITTED FOR THE ENGINEER APPROVAL
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

1.02 1.03 1.04 1.05 1.06 1.07

8200 8200 8200 8200 8200

6 1 N
10 S5307 S5307
KEY PLAN
1.B 820
0

250mm. THICK C.I.P SLAB


+5.750 SSL
8
9 +6.250 SSL T.O.W AROUND S5307
T.O.W AROUND S5307 THE PLANTER
MESH T12@150 T&B (BW) =+6.55 SSL
THE PLANTER
4 =+6.55 SSL
S5307
9 PLANTER 250mm. THICK C.I.P SLAB 250mm. THICK C.I.P SLAB 250mm. THICK C.I.P SLAB
PLANTER
MESH T12@150 T&B (BW) +6.100 SSL +5.550 SSL
9500

+6.250 SSL
112
250mm. THICK C.I.P SLAB 00
+5.550 SSL MESH T12@150 T&B (BW)
General Notes:
MESH T12@150 T&B (BW)
1. DO NOT SCALE FROM THIS DRAWING.
7 250mm. THICK C.I.P SLAB
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
S5307 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
200mm. THICK C.I.P SLAB +5.750 SSL
T.O.W AROUND BY THE ENGINEER.
THE PLANTER MESH T12@150 T&B (BW) +5.100 SSL
=+6.55 SSL MESH T12@150 T&B (BW) 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 MESH T12@150 T&B (BW) AT SITE.
T.O.W=+6.55 SSL
1.A 250mm. THICK C.I.P SLAB 11 T.O.W AROUND 1C'
T.O.W AROUND 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
THE PLANTER

0
THE PLANTER +5.550 SSL S5307

220
+5.550 SSL PLANTER =+5.95 SSL
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
=+5.95 SSL AND RELEVANT SECTIONS OF THE SPECIFICATION.
250mm. THICK C.I.P SLAB 250mm. THICK C.I.P SLAB
+5.550 SSL
5 250mm. THICK C.I.P SLAB
T.O.W=+6.05 SSL
250mm. THICK C.I.P SLAB S5307
300mm. THICK C.I.P SLAB
+5.750 SSL +5.750 SSL 1B'
PLANTER T.O.W=+6.05 SSL PLANTER
2 +5.750 SSL +5.550 SSL
MESH T12@150 T&B (BW) +5.750 SSL
S5307 MESH T12@150 T&B (BW)

7 250mm. THICK C.I.P SLAB

3
S5307 MESH T12@150 T&B (BW) MESH T16@150 T&B (BW)

1.10

SWIMMING POOL AREA 1.08 1.09


1 SCALE 1 : 100
6

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
1.02 1.03 1.04 1.05 1.06 1.07 Client:

5
8200 8200 8200 8200 8200 MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
820 E: info@dubairacingclub.com W: www.dubairacingclub.com
0
640 Principal Consultant:
1.B
610

200 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4 4980 645 230 2345 3210 4990 1475 Sub-Consultant:

200
1455 1650
200

1360
200

200 112
300 00
300 300
9500

2400

350 200 3235 200

3500
300 300 200

3905 4035
3325

300 200
3960 4650
300
300

350 8110 Project Name:

300
DUBAI WATER CANAL
2500

2915

300
3
3200

3200

SAFA A

2100
350 200 3305
300

DUBAI-UAE
3685 1C'
200 400

300
300

8200
200

2050
200 200

1.A
200

1325
200

0
220
1930 Project Description:

200 8200 8200 8200 8200 MIXED USE DEVELOPMENT


2805

236
0 1B' (RETAIL & RESIDENTIAL)
0 200 3550 200
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
200

200
10655
Drawing Title:

SLAB DETAILS - 06

1.08 1.09 1.10


Scale Drawn Checked Approved Size
AA MA NS
1 : 100 A1
1
UPSTANDS LAYOUT 20.07.2017 24.08.2017 24.08.2017
2 SCALE 1 : 100 Drawing Number Rev.

14011603-01-00-S5306 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

200 300 2200 300 3800 300 2200 200 3200


DUBAI MUNICIPALITY STAMP:

11 +6.250 SSL

350

350
+6.100 SSL

250
700
P.T SLAB
+5.925 SSL

250
+5.750 SSL T12 @150

280
T12 @150
T12 @150
SWIMMING POOL T12 @150

250
T12 @150 T12 @150
T12 @150 T12 @150
T12 @150 T12 @150 T12 @150
T12 @150 T12 @150 T12 @150
50mm TH. FIXABLE FILLER BOARD +5.100 SSL N
10 DETAILS AS PER BEAM SCHEDULE KEY PLAN
DETAILS AS PER BEAM SCHEDULE

200
+4.850 SSL

50
500

500
AS PER SLAB
REINFORCEMENT

9
SECTION 1-1
1 SCALE 1 : 25
General Notes:
P.T SLAB
+5.925 SSL 1. DO NOT SCALE FROM THIS DRAWING.
SELF ADHESIVE MEMBRANE AS PER SPEC. AS PER PLAN
200 200 +5.75 SSL 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS

280
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

250
BY THE ENGINEER.

250
T12 @150 T12 @150 T12 @150
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

AS PER ARCH.
MAX. 800mm
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 T12 @150 T12 @150 T12 @150
T12 @150 AT SITE.
SELF ADHESIVE MEMBRANE P.T SLAB T12 @150
AS PER SPEC. 200 +5.925 SSL 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
PLANTER ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AS PER ARCH.
MAX. 400mm

T12 @150 200 +5.75 SSL +4.85 SSL AND RELEVANT SECTIONS OF THE SPECIFICATION.
T12 @150 +5.75 SSL
PLANTER

280
+4.85 SSL DETAILS AS PER BEAM SCHEDULE
+5.55 SSL +5.550 SSL DETAILS AS PER BEAM SCHEDULE
250

500
250

500
T12 @150
T12 @150

T12 @150 T12 @150


T12 @150 DETAILS AS PER BEAM SCHEDULE
T12 @150 DETAILS AS PER BEAM SCHEDULE AS PER SLAB
7 AS PER SLAB
REINFORCEMENT
REINFORCEMENT

SECTION 2-2 SECTION 3-3 SECTION 4-4


2 3 4
SCALE 1 : 25 SCALE 1 : 25 SCALE 1 : 25 SECTION 5-5
+6.250 SSL
T12 @150
T12 @150 5 SCALE 1 : 25
T12 @150
T12 @150 P.T SLAB

250
+6.25 SSL
+5.925SSL
250

P.T SLAB P.T SLAB


325

6 +5.925 SSL +5.925 SSL

280
280

280

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
DETAILS AS PER BEAM SCHEDULE
T12 @150 Purpose of Issue Rev. Date Appoved
T12 @150
+5.10 SSL +4.850 SSL
Client:
DETAILS AS PER BEAM SCHEDULE DETAILS AS PER BEAM SCHEDULE
50 200

+4.85 SSL
500

5
50mm TH. FIXABLE FILLER BOARD
MEYDAN L.L.C
180 P.O. Box 9305, Dubai , UAE.
500

500

T: +9714 3270000 F: +9714 3270007


E: info@dubairacingclub.com W: www.dubairacingclub.com

200
AS PER SLAB +6.250 SSL
Principal Consultant:
REINFORCEMENT
T8@200/STEP

250
AS PER SLAB AS PER SLAB
T8/STEP
REINFORCEMENT REINFORCEMENT
T16@200mm
T12 @150 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
T12 @150 T12@200mm www.ae-7.com
200

200
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
4 SECTION 6-6 SECTION 7-7 SECTION 8-8 P: +971 4 3997758 F: +971 4 3997759

6 SCALE 1 : 25
7 SCALE 1 : 25
8 SCALE 1 : 25 T12 @150
Sub-Consultant:
T12 @150
+5.100 SSL 50mm TH. FIXABLE FILLER BOARD

T12 @150

50 200
+4.850 SSL T12 @150

500
Project Name:

3
DUBAI WATER CANAL
AS PER SLAB SAFA A
400 WALL THICK REINFORCEMENT
DUBAI-UAE

SECTION 9-9
9 SCALE 1 : 25
Project Description:

T16 @200
200 200 MIXED USE DEVELOPMENT
T12 @200
(RETAIL & RESIDENTIAL)
AS PER ARCH.
MAX. 800mm

4T10
+5.75 SSL T12 @150
PLOT 01 / 3435338
SLAB THICK

T12 @150
+5.55 SSL T12 @150
250

2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)


360
300

Drawing Title:
FOR REINF. REFER
TO CORE WALL DETAILS
T16 @150
T16 @150
DETAILS AS PER BEAM SCHEDULE SLAB DETAILS - 07

Scale Drawn Checked Approved Size


AA MA NS
1 SECTION 10-10 1 : 25 A1
SECTION 10-10 11 20.07.2017 24.08.2017 24.08.2017
10 SCALE 1 : 25
SCALE 1 : 25
Drawing Number Rev.

14011603-01-00-S5307 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

2.12 2.12
DUBAI MUNICIPALITY STAMP:
2.11 2750 2.11
1.04 1.05 1.04 1.05 2750

11 6750
6750
50 6800 1400 50 6800 1400 200

250mm. THICK C.I.P SLAB 250mm. THICK C.I.P SLAB

2250
+3.595 SSL +4.445 SSL
MESH T12@200 T&B (BW)
5500 MESH T12@200 T&B (BW)

5550
5550
+3.645 +4.445

3250
10
MESH T12@200 T&B (BW) MESH T12@200 T&B (BW)
2.B 2.B KEY PLAN

1.C 1.C

ATTIC SLAB BUILDING 01


1

4125
SCALE 1 : 100

5125
9
2600

2600
General Notes:
ATTIC SLAB BUILDING 02 1. DO NOT SCALE FROM THIS DRAWING.

2 SCALE 1 : 100
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
2.12 2.12 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
2.01 2.02 2.01 2.02 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 1525 2.G AT SITE.
UB 203x133x25 2.G
2.11 2.11 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
2.G' 2.G' 3x25
UB 203x13 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

3x25
UB 203x13
UB 203x133x25
7 7

2-2B1
S5308 S5308
485
2300

UB 203x13
3x25
UB 203x133x25 UB 203x13
7
2-2B1

3x25
8 8
S5308 S5308
3x25
UB 203x13

4300
UB 203x133x25
UC 254x254x167
UB 203x133x25

280mm. THICK P.T SLAB

UC 254x25
+9.525 SSL B
ICK P.T SLA

UB 203x13
300mm. TH 3x25
+9.525 SS L EEL DECK UB 203x13 2.H
2.H 130mm. ST
9 9 UB 203x133x25 4x167

4x167
UC 254x25

3x25
S5308 S5308 130mm. STEEL DECK 2-2B9
1700

2-2B1
6 UB 203x133x25 +9.525 SSL P.C. +8.630 SS
L
2.H' 2.H' 4x167
B UC 254x25
ICK P.T SLA
300mm. TH
UC 254x254x167

2300

1700
1700

300mm. THICK P.T SLAB


+9.525 SSL +8.630 SSL
P.C. 7500 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
3x25
UB 203x13
3400

UC 254x254x167 AUTHORITY APPROVAL 0 17.08.2017 NS

UB 203x13
1300 300
Purpose of Issue Rev. Date Appoved
UB 203x133x25
Client:

3x25
UB 203x133x25

UB 203x133x25

UB 203x133x25

UB 203x133x25

UB 203x133x25

100
5 5 6 6
S5308 S5308 S5308 S5308
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.

STEEL CANOPY-01 AT BUILDING 02 LEVEL 02 STEEL CANOPY-02 AT BUILDING 02 LEVEL 02


T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
3 SCALE 1 : 100
4 SCALE 1 : 100
Principal Consultant:
AS PER PLAN

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PT SLAB PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
150 1T10
Sub-Consultant:
STEEL AS PER PLAN

125
T10@200 DECK BEAM AS PER
SCHEDULE

Ld Ld STEEL BEAM IN
6T10 AS PER PLAN 6T10 AS PER PLAN AS PER PLAN
ELEVATION
CONNECTION AS PER
AS PER PLAN SUPPLIER DETAIL Project Name:
525

525

3 T10@200 PT SLAB PT SLAB T10@200 PT SLAB PT SLAB PT SLAB


DUBAI WATER CANAL
STEEL CANOPY SECTION 4 SAFA A
150 1T10 150 1T10 150 1T10 8 SCALE 1 : 25 DUBAI-UAE
AS PER PLAN STEEL AS PER PLAN STEEL STEEL AS PER PLAN
125

125

125

T10@200 DECK BEAM AS PER T10@200 DECK BEAM AS PER T10@200 DECK BEAM AS PER
SCHEDULE SCHEDULE SCHEDULE
Project Description:

200 AS PER PLAN


PT SLAB
MIXED USE DEVELOPMENT
CONNECTION AS PER STEEL BEAM IN
STEEL BEAM IN
ELEVATION
STEEL BEAM IN
ELEVATION SUPPLIER DETAIL ELEVATION +9.600 SSL
AS PER PLAN
(RETAIL & RESIDENTIAL)
CONNECTION AS PER CONNECTION AS PER
STEEL BEAM IN STEEL BEAM IN STEEL BEAM IN PLOT 01 / 3435338

75
AS PER PLAN SUPPLIER DETAIL AS PER PLAN AS PER PLAN SUPPLIER DETAIL
ELEVATION ELEVATION ELEVATION

THICK
SLAB
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)

600
STEEL STEEL STEEL
COLUMN IN COLUMN IN COLUMN IN
ELEVATION ELEVATION ELEVATION T12@150 Drawing Title:
WALL AS PER
T12@150
SCHEDULE

SLAB DETAILS - 08
STEEL CANOPY SECTION 1 STEEL CANOPY SECTION 2 STEEL CANOPY SECTION 3
5 SCALE 1 : 25
6 SCALE 1 : 25
7 SCALE 1 : 25 STEEL CANOPY SECTION 5
9
Scale Drawn Checked Approved Size
As AA MA NS
1 SCALE 1 : 25 A1
indicated 20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

NOTE: STRUCTURAL STEEL ELEMENTS (COLUMNS,BEAMS, CONNECTIONS, ETC…)


SHOWN IN DRAWINGS FOR INDICATIVE ONLY TO BE DESIGNED AND VERIFIED BY THE
14011603-01-00-S5308 0
STRUCTURAL STEEL CONTRACTOR AND SUBMITTED FOR THE ENGINEER APPROVAL
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN
1 1
S5502 S5502

ST1-01 - BASEMENT 01 LEVEL ST1-01 - LEVEL 02


9 1 SCALE 1 : 50
4 SCALE 1 : 50

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

1 1
S5502 S5502
7

ST1-01 - GROUND LEVEL ST1-01 - LEVEL 03


2 SCALE 1 : 50
5 SCALE 1 : 50
6

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


1 1 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
S5502 S5502 PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

ST1-01 - LEVEL 01 ST1-01 - LEVEL 04


3 SCALE 1 : 50
6 SCALE 1 : 50 Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
1 Drawing Title:
S5502

BUILDING 01
STAIRS DETAILS - 01

Scale Drawn Checked Approved Size


AA MA NS
1 ST1-01 - LOWER ROOF LEVEL 1 : 50 A1
7 SCALE 1 : 50
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-00-S5501 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

N
10 KEY PLAN

+25.00FFL

PE
02
ROOF_01
ROOF LEVEL
General Notes:
TY
+9.60FFL
LEVEL 02 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


200 NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


TY SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 PE
02 AT SITE.

200
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

200
200

200
02
PE
TY
+21.00FFL
+6.00FFL LOWER ROOF_01
ROOF LEVEL
7 LEVEL 01
200

TY
TY PE
PE 02
02

200
200

200

200
6

200
02
PE
200

TY

02 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


PE
TY AUTHORITY APPROVAL 0 17.08.2017 NS
+16.80FFL Purpose of Issue Rev. Date Appoved
LEVEL 04
Client:
200

200
TY
PE
5 02 TYP
E0
MEYDAN L.L.C
200

200
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
+0.00FFL
GROUND LEVEL Principal Consultant:

200
200

200
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
2
E0
200

www.ae-7.com
TYP Hassanicor Building, 6th Floor, Al Barsha 1
02 PO Box 54115 Dubai, UAE
PE
4 TY +13.20FFL P: +971 4 3997758 F: +971 4 3997759
LEVEL 03 Sub-Consultant:

200
200

TYP
E0
2

200
TY
PE
01
200

Project Name:

200
3
DUBAI WATER CANAL
-4.50SSL
SAFA A
BASEMENT 01 LEVEL
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
ST1-01 SECTION 1
1
Drawing Title:
SCALE 1 : 50
BUILDING 01
STAIRS DETAILS - 02

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 50 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.
*NOTE:
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5508
14011603-01-00-S5502 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

1 1 1 1
S5504 S5504 S5504 S5504

N
10 KEY PLAN

General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

ST1-02 - BASEMENT 01 LEVEL ST1-02 - GROUND LEVEL ST1-02 - LEVEL 01 ST1-02 - LEVEL 02
1 SCALE 1 : 50
2 SCALE 1 : 50
3 SCALE 1 : 50
4 SCALE 1 : 50
7

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


1 1 1 AUTHORITY APPROVAL 0 17.08.2017 NS
S5504 S5504 S5504
Purpose of Issue Rev. Date Appoved
Client:

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh


www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


ST1-02 - LEVEL 03 ST1-02 - LEVEL 04 ST1-02 - LOWER ROOF LEVEL
5 SCALE 1 : 50
6 SCALE 1 : 50
7 SCALE 1 : 50
(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

BUILDING 01
STAIRS DETAILS - 03

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 50 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-00-S5503 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

1.A
1.A

N
10 KEY PLAN

200
200
E 02
TYP
9
+9.60FFL
LEVEL 02

200
General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

200
TY
PE
02 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

+21.40SSL 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

200
ROOF_02
ROOF LEVEL SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

200
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT

200
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.
E 02
TYP

+6.00FFL

200
LEVEL 01 TY
PE
02
200

TY
PE
7 02

200
200

200
02
200

PE
TY
+17.40SSL
LOWER
LOWER ROOF_02
ROOF LEVEL
200

02
PE
TY

200
6
200

TY
PE
TY 02
PE 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

200
02
AUTHORITY APPROVAL 0 17.08.2017 NS
200

Purpose of Issue Rev. Date Appoved


Client:

200
200

200
+0.00FFL
5 GROUND LEVEL 02
PE
TY MEYDAN L.L.C
200

P.O. Box 9305, Dubai , UAE.


+13.20FFL T: +9714 3270000 F: +9714 3270007
02 LEVEL 03 E: info@dubairacingclub.com W: www.dubairacingclub.com
PE
TY
Principal Consultant:

200
200

TY
PE abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
02

200
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
200

TY PO Box 54115 Dubai, UAE


PE
01 P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:

200
200
02
PE
TY

+9.60FFL
LEVEL 02
-4.50SSL Project Name:

200
BASEMENT 01 LEVEL

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
ST1-02 SECTION 1
1 SCALE 1 : 50
Drawing Title:

BUILDING 01
STAIRS DETAILS - 04

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 50 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

*NOTE: 14011603-01-00-S5504 0
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5508
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

+21.40SSL
ROOF_02
ROOF LEVEL
DUBAI MUNICIPALITY STAMP:
1 1
S5505 S5505

11

N
10 KEY PLAN

200
+17.40SSL
LOWER ROOF_02
LEVEL 04

200
02
PE
TY

9
TYPE 03

200
General Notes:
1. DO NOT SCALE FROM THIS DRAWING.
TY
PE
02 2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

200
BY THE ENGINEER.

200
+13.20FFL 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
8 ST2-01 - BASEMENT 01 LEVEL ST2-01 - LEVEL 02 LEVEL 03 SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK

2 5
AT SITE.

SCALE 1 : 50 SCALE 1 : 50 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS

200
AND RELEVANT SECTIONS OF THE SPECIFICATION.
1
02
S5505 PE
TY
1

200
S5505

7 TY
PE
02

200

200
+9.60FFL
LEVEL 02

02

200
PE
TY
6

200
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 17.08.2017 NS
TY
PE Purpose of Issue Rev. Date Appoved
02

200
Client:

200
+6.00FFL
LEVEL 01

5
MEYDAN L.L.C
02 P.O. Box 9305, Dubai , UAE.

200
PE
TY T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

200
ST2-01 - LEVEL 03
Principal Consultant:

6
ST2-01 - GROUND LEVEL SCALE 1 : 50
3 SCALE 1 : 50 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
TY Hassanicor Building, 6th Floor, Al Barsha 1
PE
02 PO Box 54115 Dubai, UAE
1 1 P: +971 4 3997758 F: +971 4 3997759

200
4
S5505 S5505

200
Sub-Consultant:

TYPE 03

Project Name:
02
PE DUBAI WATER CANAL

200
TY
3
SAFA A

200
+0.00FFL
GROUND LEVEL DUBAI-UAE

Project Description:

TY
PE
MIXED USE DEVELOPMENT
02
(RETAIL & RESIDENTIAL)

200
PLOT 01 / 3435338

200
2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
TYPE 03
Drawing Title:

BUILDING 02
01
STAIRS DETAILS - 05
PE

200
TY

Scale Drawn Checked Approved Size


AA MA NS
1 -4.50SSL 1 : 50 A1
BASEMENT 01 LEVEL 20.07.2017 24.08.2017 24.08.2017

ST2-01 - LEVEL 01 ST2-01 - LOWER ROOF LEVEL ST2-01 SECTION 1 Drawing Number Rev.
4 SCALE 1 : 50
7 SCALE 1 : 50
1 SCALE 1 : 50
*NOTE: 14011603-01-00-S5505 0
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5508
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

2.F

+21.40SSL
DUBAI MUNICIPALITY STAMP:
ROOF_02
ROOF LEVEL

11

1
1 1
S5506
S5506 S5506

N
10 KEY PLAN

200
+17.40SSL
LOWERLEVEL
ROOF_02
04

02
PE

200
TY

200
General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

200
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
TY NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
PE
02 BY THE ENGINEER.

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES

200
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 +13.20FFL AT SITE.
LEVEL 03
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

200
02
PE
TY

200
ST2-02 - BASEMENT 01 LEVEL ST2-02 - GROUND LEVEL ST2-02 - LEVEL 01
2 3 SCALE 1 : 50
4 SCALE 1 : 50
7 SCALE 1 : 50

TY
PE
02

200

200
+9.60FFL
LEVEL 02

200
02
6 PE
TY

200
100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS
AUTHORITY APPROVAL 0 17.08.2017 NS
TY Purpose of Issue Rev. Date Appoved
PE
1 1 02
Client:
S5506 S5506
1

200

200
S5506 +6.00FFL
LEVEL 01
5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007

200
E: info@dubairacingclub.com W: www.dubairacingclub.com

02
Principal Consultant:
PE
TY

200
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE
P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:
TY
PE
02

200

200
Project Name:

200
3 02
DUBAI WATER CANAL
PE
TY SAFA A

200
+0.00FFL
DUBAI-UAE
GROUND LEVEL

Project Description:

MIXED USE DEVELOPMENT


TY
PE
02 (RETAIL & RESIDENTIAL)
ST2-02 - LEVEL 02 PLOT 01 / 3435338
5

200
ST2-02 - LEVEL 03

200
SCALE 1 : 50
2
6 SCALE 1 : 50 ST2-02 - LOWER ROOF LEVEL
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
7 SCALE 1 : 50
Drawing Title:

BUILDING 02

200
01
STAIRS DETAILS - 06
PE
TY

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 50 A1
-4.50SSL 20.07.2017 24.08.2017 24.08.2017
BASEMENT 01 LEVEL
Drawing Number Rev.
ST2-02 SECTION 1 14011603-01-00-S5506
1 SCALE 1 : 50
*NOTE: 0
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5508
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11 1
S5507

+21.40SSL
ROOF_02
ROOF LEVEL

N
10 KEY PLAN
1
S5507

ST2-03 - GROUND LEVEL


2 SCALE 1 : 50
9
+17.40SSL

200
LOWER ROOF_02
LEVEL 04

General Notes:
02

200
PE
TY 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.

ST2-03 - LEVEL 03 TYPE 03 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


8 5 SCALE 1 : 50
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
AT SITE.

200
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

TY
PE
02
1

200
S5507

+13.20FFL
LEVEL 03

200
7
02
PE
TY

200
200
TY
1 PE
02
6 S5507

200
+9.60FFL

ST2-03 - LEVEL 01 LEVEL 02

3 100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS

200
SCALE 1 : 50 AUTHORITY APPROVAL 0 17.08.2017 NS
02 Purpose of Issue Rev. Date Appoved
PE
TY

200
Client:

5
MEYDAN L.L.C

200
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com
TY
PE
02 Principal Consultant:

200
ST2-03 - LOWER ROOF LEVEL +6.00FFL

6
LEVEL 01
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh

200
www.ae-7.com
SCALE 1 : 50 Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE

200
4 1 P: +971 4 3997758 F: +971 4 3997759
S5507
02 Sub-Consultant:
PE
TY

TYPE 03

200
Project Name:

3
TY
PE
02
DUBAI WATER CANAL
SAFA A

200
DUBAI-UAE

200
Project Description:

MIXED USE DEVELOPMENT

200
ST2-03 - LEVEL 02 (RETAIL & RESIDENTIAL)
4 SCALE 1 : 50 TY
PE
01
PLOT 01 / 3435338
2 +0.00FFL
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
GROUND LEVEL
Drawing Title:

BUILDING 02
STAIRS DETAILS - 07

ST2-03 SECTION 1 Scale Drawn Checked Approved Size


1 SCALE 1 : 50 1 : 50
AA MA NS
A1
1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.
*NOTE:
FOR FLIGHTS REINFORCEMENTS AND TYPES REFER TO DWG S5508
14011603-01-00-S5507 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

SHEAR WALL

T12@150mm N
10 KEY PLAN
T8@150/STEP

200
T8/STEP
T12@150mm
T16@150mm
T12@150mm
T16@150mm

200
T16@150mm

T12@150mm AS PER
PLAN REIN.

AS PER PLAN
9

General Notes:
TYPE 01
1 SCALE 1 : 25
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


50MM PROTECTION
SCREED NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
WATER PROOFING AS
PER PROJECT SPECT. 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 75mm BLINDING AT SITE.
COMPACTED FILL
95% PROCTOR TEST 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

SHEAR WALL / BEAM


T12@150mm
T12@150mm

7 T12@150mm

200
SHEAR WALL / BEAM
T8@150
T8-STEP T16@150mm
T8@150
T8-STEP T16@150mm
T12@150mm
T12@150mm

200
T16@150mm

200
T16@150mm T12@150mm
6
T16@150mm

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

TYPE 02
5 2 SCALE 1 : 25 MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:

SHEAR WALL / BEAM abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
T12@150mm www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
T12@150mm
PO Box 54115 Dubai, UAE
4 T12@150mm P: +971 4 3997758 F: +971 4 3997759
Sub-Consultant:
200

SHEAR WALL / BEAM


T8@150
T8-STEP T16@150mm
T8@150
T8-STEP T16@150mm
T12@150mm
T12@150mm
200

T16@150mm
200

Project Name:

3
T16@150mm T12@150mm DUBAI WATER CANAL
T16@150mm SAFA A
DUBAI-UAE

Project Description:

MIXED USE DEVELOPMENT


(RETAIL & RESIDENTIAL)
PLOT 01 / 3435338
TYPE 03
2 3 SCALE 1 : 25
BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

STAIRS DETAILS - 08

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 25 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-00-S5508 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

1 1.A DUBAI MUNICIPALITY STAMP:


S5602

11

3 1.B 1.C 1.D N


10 300 THICK. CIP RAMP
S5106 KEY PLAN

01 2
S5602 300 THICK. CIP RAMP

T12@150 (B)
CONITNOUS

CONITNOUS
T12@150 (T)

T20@150 (B)
T12@150 (T)
9
3
S5106 T12@150 (T)
T12@150 (T) T12@150 (T)

T12@150 (B) T12@150 (B) T12@150 (B)


General Notes:
1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
01 BY THE ENGINEER.
T12@150 (T)

3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES


T20@150 (B) SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.

4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT


02 ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
AND RELEVANT SECTIONS OF THE SPECIFICATION.

RAMP 1 - GROUND LEVEL


2 SCALE 1 : 100

RAMP 1 - BASEMENT 01 LEVEL


1 SCALE 1 : 100

2.09 2.10
6 2
S5603
2.A

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:
2-GB31

5
MEYDAN L.L.C

T12@150 (B)
T12@150 (T)
2.08 2.09 2.10 2.11 2.12 P.O. Box 9305, Dubai , UAE.
T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

2-GB31
Principal Consultant:

2-GB31
T12@150 (B)
T12@150 (T)

300 THICK. CIP RAMP abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
2.B Hassanicor Building, 6th Floor, Al Barsha 1
PO Box 54115 Dubai, UAE

T12@150 (B)
T12@150 (T)
T12@150 (T) P: +971 4 3997758 F: +971 4 3997759
4
Sub-Consultant:
T20@150 (B) 300 THICK. CIP RAMP

T12@150 (T)

T20@150 (B)
2.D

2.07 Project Name:

3
DUBAI WATER CANAL
SAFA A
DUBAI-UAE
3

T12@150 (B)
T12@150 (T)
S5603 2.C Project Description:
T12@150 (B)
T12@150 (T)

MIXED USE DEVELOPMENT


300 THICK. CIP RAMP
(RETAIL & RESIDENTIAL)
T12@

P
IP RAM
T12@

ICK. C T12@150 (B)


300 TH
1 CONITNOUS
PLOT 01 / 3435338
150 (T
15

S5603 T12@150 (T)


0 (B)

2 CONITNOUS BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)


)

)
150 (T 3
T12@ OUS
ITN
CO N
) S5603 3 Drawing Title:
150 (B
T12@ OUS S5603
NITN 2.E
CO

S5603
3 RAMP DETAILS - 01
3
S5603

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 100 A1
20.07.2017 24.08.2017 24.08.2017
RAMP 2 - BASEMENT 01 LEVEL RAMP 2 - GROUND LEVEL
3 SCALE 1 : 100
4 SCALE 1 : 100
Drawing Number Rev.

14011603-01-00-S5601 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

200 AS PER PLAN 200

SELF ADHESIVE MEMBRANE AS PER SPEC.

AS PER ARCH.
MAX. 1600 mm
N
10 T12@200
T12@200 AS PER SLAB
T12@200
T12@200
KEY PLAN
REINFROCEMENT PLANTER
+0.800 SSL 350

AS PER SLAB

350

350
REINFROCEMENT
+0.400 SSL

BEAM AS ER SCHEDULE
400

50MM PROTECTION
T20 @200 SCREED
T16 @150 WATER PROOFING AS
PER PROJECT SPECT.
75mm BLINDING
COMPACTED FILL
PROTECTION BOARD 95% PROCTOR TEST
9
WATER PROOFING
AS PER SPEC.

SHOTCRETE
SECANT PILE WALL General Notes:
T12 @150
(REFER TO SHORING DETAILS)
T12 @150 1. DO NOT SCALE FROM THIS DRAWING.

2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS


NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED

300
BY THE ENGINEER.
T12 @150 T20 @150 AS PER RAFT
REINFROCEMENT 3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
300 -3.500 SSL SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
300
500

500
4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
500

AND RELEVANT SECTIONS OF THE SPECIFICATION.

T12 @150 50MM PROTECTION


SCREED
WATER PROOFING AS
PER PROJECT SPECT.
75mm BLINDING
COMPACTED FILL
RAMP 1 - SECTION 1 95% PROCTOR TEST

7 1 SCALE 1 : 50

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
250
Purpose of Issue Rev. Date Appoved
Client:
AS PER ARCH.

T12 @200
MAX. 1600 mm

T12 @200
AS PER SLAB 75mm BLINDING
5 REINFROCEMENT WATER PROOFING AS
+1.000 SSL
PER PROJECT SPECT. MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
350 50 350 T: +9714 3270000 F: +9714 3270007
350

E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
50mm TH. FIXABLE
T12 @150 FILLER BOARD
T20 @150 T12 @150
T20 @200
T16 @150 abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
T20 @150 www.ae-7.com
Hassanicor Building, 6th Floor, Al Barsha 1
T12 @150 PO Box 54115 Dubai, UAE
PROTECTION BOARD P: +971 4 3997758 F: +971 4 3997759
4
T12 @150 WATER PROOFING Sub-Consultant:
300

T12 @150 AS PER SPEC.


SHOTCRETE
300 50

SECANT PILE WALL


(REFER TO SHORING DETAILS)

WATER STOPPER WATER STOPPER


T12 @150 AS PER SPEC.
AS PER SPEC. T16 @150
T12 @150
T16 @150 50mm TH. FIXABLE
-3.100 SSL
AS PER RAFT FILLER BOARD
Project Name:
REINFROCEMENT
350

-3.500 SSL

3
DUBAI WATER CANAL
50
500

SAFA A
DUBAI-UAE
50MM PROTECTION
SCREED
WATER PROOFING AS Project Description:
PER PROJECT SPECT.
75mm BLINDING MIXED USE DEVELOPMENT
RAMP 1 - SECTION 2 COMPACTED FILL
(RETAIL & RESIDENTIAL)
2
95% PROCTOR TEST

SCALE 1 : 50 PLOT 01 / 3435338


2 BLDG 01(1B+G+4+R) , BLDG 02(1B+G+4)
Drawing Title:

RAMP DETAILS - 02

Scale Drawn Checked Approved Size


AA MA NS
1 1 : 50 A1
20.07.2017 24.08.2017 24.08.2017
Drawing Number Rev.

14011603-01-00-S5602 0
All rights reserved. No part of this drawing may be reproduced or transmitted in any forms by any means without written permission of the copyright holder. © AE-7
A B C D E F G H J K L M N P Q

DUBAI MUNICIPALITY STAMP:

11

AS PER SLAB AS PER SLAB AS PER SLAB


AS PER SLAB REINFROCEMENT REINFROCEMENT REINFROCEMENT
-0.200 SSL -0.200 SSL AS PER SLAB
REINFROCEMENT REINFROCEMENT N
-0.400 SSL -0.400 SSL
10 KEY PLAN

BEAM AS ER SCHEDULE
BEAM AS ER SCHEDULE

300 300

T12 @150 T12 @150

1000

1000
T12 @150 T12 @150

9 T12 @150 T12 @150


T20 @150 T12 @150 T12 @150 T20 @150

General Notes:
AS PER RAFT AS PER RAFT
T12 @150 T12 @150 1. DO NOT SCALE FROM THIS DRAWING.
REINFROCEMENT REINFROCEMENT
300 -4.500 SSL -4.500 SSL 300
2. DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN METERS UNLESS
300

300
NOTED OTHERWISE. DIMENSIONS ARE TO BE VERIFIED ON SITE & APPROVED
BY THE ENGINEER.
500

500
3. DISCREPANCIES BETWEEN ARCHITECTURAL, STRUCTURAL & SERVICES
SHALL BE BROUGHT TO ARCHITECTS NOTICE PRIOR TO EXECUTION OF WORK
8 AT SITE.
50MM PROTECTION
T12 @150 SCREED T12 @150 4. ALL DRAWINGS SHOULD BE READ IN CONJUNCTION WITH OTHER RELEVANT
WATER PROOFING AS ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, CIVIL DRAWINGS
PER PROJECT SPECT. AND RELEVANT SECTIONS OF THE SPECIFICATION.
75mm BLINDING
COMPACTED FILL
95% PROCTOR TEST

RAMP 2 -SECTION 1
1 SCALE 1 : 50

100% CONSTRUCTION DOCUMENTS FOR TENDER 0 24.08.2017 NS


AUTHORITY APPROVAL 0 17.08.2017 NS
Purpose of Issue Rev. Date Appoved
Client:

5
MEYDAN L.L.C
P.O. Box 9305, Dubai , UAE.
300 T: +9714 3270000 F: +9714 3270007
E: info@dubairacingclub.com W: www.dubairacingclub.com

Principal Consultant:
WATER PROOFING AS
PER PROJECT SPECT.
T12 @150 75mm BLINDING 300
T20 @150 T12 @150
abu dhabi . amman . bratislava . dubai . karbala . oberhausen . pittsburgh
www.ae-7.com
T12 @150 Hassanicor Building, 6th Floor, Al Barsha 1

1000
PO Box 54115 Dubai, UAE
T12 @150
P: +971 4 3997758 F: +971 4 3997759
4 VAR.
Sub-Consultant:

T16 @200
T20 @150

PROTECTION BOARD

WATER PROOFING
AS PER SPEC.
Project Name:
SHOTCRETE

3
SECANT PILE WALL
(REFER TO SHORING DETAILS)
DUBAI WATER CANAL
AS PER RAFT
REINFROCEMENT 50MM PROTECTION
SAFA A
-4.500 SSL
SCREED
WATER PROOFING AS DUBAI-UAE
PER PROJECT SPECT.
75mm BLINDING
COMPACTED FILL Project Description:
95% PROCTOR TEST

S-ar putea să vă placă și