Sunteți pe pagina 1din 669

CHAPTER I

THE PROBLEM

Introduction:

Elevation involves raising a building in place so that the

finished living space is located above the anticipated height of

flood waters. The building is separated from its foundation and

placed on a new or extended foundation. The building can be

elevated on solid perimeter foundation walls, fill, or an open

foundation system that supports the structure at key points.

Elevated building is a structure that has no basement and has

its lowest floor level raised above the ground level by means of

foundation walls, shear walls, pilings or the likes. It is a type

of structure commonly built in a flood hazard area in which the

supports of the structure are built parallel to the flow of water

adequately anchored or properly buried so as not to impair the

structural integrity of the building during a flood.

A flood is an overflow of water on normally dry ground due.

This is most commonly to an overflowing river, a dam break,

snowmelt, or heavy rainfall. Less commonly happening are tsunamis,


storm surge, or coastal flooding. Floods impact on both individuals

and communities, and have social, economic, and environmental

consequences. The consequences of floods, both negative and

positive, vary greatly depending on the location and extent of

flooding, and the vulnerability and value of the natural and

constructed environments they affect. For a structure, standing

water is a fearsome enemy. Even a small amount of flooding in a

home can exile its inhabitants for weeks and require costly

repairs. Floods can happen anywhere at any time, which is why it

is important to be prepared and to take steps before a flood event,

to protect your property from costly damage. Taking action to

reduce the impact of a disaster is known as mitigation. The

ultimate goal of any mitigation measure is to reduce or eliminate

the potential of flood damage in a way that is cost effective,

complies with all applicable floodplain regulations, and is

acceptable to the owner of the structure in terms of appearance

and livability. There are a variety of flood mitigation options

laid before us using technology and other methods. One familiar

mitigation measure is the elevation of structure above the base

flood elevation or BFE. Structural elevation above flood levels is

a common, well-recognized, and productive measure for reducing

flood risk and often the most effective measure to reduce flood

damage as well as it is a key for flood protection. Buildings that

are situated at or above the level of the base flood elevation


(BFE) have lower flood risk than buildings below BFE. Elevating

the lowest floor of buildings has been proven to be effective at

reducing damages to building elements and contents located below

the BFE.

Statement of the Problem:

This study entitled “Analysis and Design of an Elevated

Multipurpose Building”, aims to design an elevated building that

meets the need of present – day and the standard of today’s

challenges, predicaments and will be in Barangay Bucayao, Calapan

City. A place with enough area to accommodate all the possible

attendees from any different location. At the same time, the

researchers should design a safe and economical structure that

will meet the needs of the community for the long run.

Flood is one of the most disastrous phenomena known to man.

It can affect more people than any other natural disaster. Flooding

occurs when bodies of water flow onto land that is normally dry.

Bucayao is a barangay in the city of Calapan, in the province

of Oriental Mindoro. Its population as determined by the 2015

Census was 2,667. This represented 1.99% of the total population


of Calapan. With this population in a certain barangay, surely

there will be lots of events and gatherings from the residents and

guests from other areas of the city and even the whole province.

Which explains the need for a proper facility for such gatherings

and events. The proposed multipurpose building of the researcher

will be one of key for the need of adequate facility.

Significance of the Study:

The significance of this study is to present a step by step

manner of analysis and design of an elevated multipurpose two

storey building following the rules, regulations, and

specifications under the National Structural Code of the

Philippines (NSCP) 2010 Volume 1 and the National Building Code of

the Philippines (NBCP); The 2004 Revised Implementing Rules and

Regulations of Presidential Decree 1096.

The goal of this study is to design a two storey elevated

multipurpose building with structural integrity in a flood prone

area. The proposed multipurpose building aside from hosting a big


and formal event, it can also serve as an evacuation center in

Brgy. Bucayao during flood and other emergencies.

This would be an upright basis for those students who are

willing to do an elevated building for their future research with

the same assumptions and expectations provided by this study.

Scope and Delimitation of the Study:

To design and analyze an elevated multipurpose two-storey

building on ground subsidence, evaluation of the following outline

scope and delimitation listed below were required:

• NSCP 2010 Specifications. National Structural Code of

the Philippines 2010; Volume 1 – Buildings, Towers and

other Vertical Structures; Sixth Edition

• NBCP. National Building Code of the Philippines; The

2004 Revised Implementing Rules and Regulations (IRR) of

P.D. 1096

• The elevated multipurpose building was designed and

analyzed for a capacity of 320 people.


• Loading combinations. Buildings and other vertical

structures shall be designed to resist the load

combinations. The most critical effect can occur when

one or more of the contributing loads are not acting.

Dead load, live load, and wind loads shall be considered,

in accordance with specified load combinations.

Basic Load Combinations, where strength design or

load and resistance factor is used, structures and all

portions thereof shall resist the most critical effects

from the following combinations of factor loads.

1.4 DL

1.2 DL + 1.6 LL + 0.5 RLL

1.2 DL + 1.6 RLL + 1.0 LL

1.2 DL + 1.6 RLL + 0.8 WL

1.2 DL + 1.6 WL + 1.0 LL + 0.5 RLL

• Strength Design Method (Load Factor Design)

▪ Required Strength. Structure and structural members

should be designed to have design strength at all

sections, greater than or at least equal to

required strengths calculated for the factored

loads and forces in such combination of loads as

specified and as required by the NSCP 2010.


▪ Design strength (Strength Reduction Factors, Ø).

The design strength provided by a concrete member,

its connections to other members, its cross

sections, in terms of flexure, axial load, shear,

torsion and bearing shall be taken as the nominal

strength multiplied by the applicable strength

reduction factor Ø having the followings values:

Flexure ………………………… 0.65 to 0.90

Shear ………………………… 0.75

Axial compression with

Spiral reinforcement …………… 0.75

Other …………………………… 0.65

• Reinforced Concrete. The researcher will use reinforced

concrete on the design of main structural components

such as beams, columns, slabs (one-way slab and two-way

slab) and footing.

• Structural Steel. This study will use structural steel

on the design of other structural components such as

trusses and purlins. Also, the researcher will design

the connection of the truss members as welded.

• SI System of Units. The SI system of units is widely

adopted in the Philippines; thus, the study will present

that SI formulas and details concerning convention

center.
Definition of Terms:

Base Flood Elevation - the height to which floodwater is expected

to rise during the base flood—the flood having a one percent chance

of being equaled or exceeded in any given year.

Beam – A design so proportioned that the maximum stresses in

concrete (with strain of 0.003) and steel (with strain of fy/Es)

are reached simultaneously once the ultimate load is reached,

causing them to fail simultaneously.

Concrete – A mixture of cement, fine aggregates, coarse aggregate

that tend to bend or crush the member.

Compression – When the force act toward the body, tending to

squeeze, shorten or crush it, the body is under compression.

Dead Loads – Dead loads are loads of constant magnitude that remain

in one position. The dead load to be assumed in design consist

mainly of the weight of the structure and all material permanently

fastened and connected thereto or supported thereby.

Design Load – All applicable loads and forces or their related

internal moments used to design members. It refers to the load

multiplied by the appropriate load factor.


Design Strength – Nominal strength multiplied by a strength by a

strength reduction factor, Ø.

Evacuation Center - usually large facilities that can accommodate

people in transition due to an emergency. Buildings that have room

for people to sleep, usually on cots, and have adequate bathroom

facilities.

Elevated Building - a structure that has no basement and has its

lowest floor level raised above the ground level by means of

foundation walls, shear walls, pilings or the likes.

Elevation – distance from the ground level to the bottom part of

the structure.

Flexure – A deformation of an elastic body wherein all points

originating in a straight line are displaced in the same plane to

form a curve.

Flood Hazard Area – are defined as the area that will be inundated

by the flood event having a 1-percent chance of being equaled or

exceeded in any given year.

Force – A push or pull in a given direction on a body that changes

to change its state of motion.

Foundation - the lowest load-bearing part of a building, typically

below ground level.


Foundation Walls - masonry walls, poured concrete walls or precast

concrete walls, regardless of height, that extend above grade and

support the weight of a building.

Live loads – Live loads are loads that may change in magnitude and

position code under which the structure is being designed or that

dictated by the conditions involved. Live loads that move under

their own power are called moving loads.

Loads – the most important and most critical task of an engineer

is the determination of the loads that can be applied to a

structure during its life, and worst possible combination of these

that might occur simultaneously. Loads on a structure may be

classified as dead loads or live load (Besavilla, 2006).

NBCP – National Building code of the Philippines.

NSCP - National Structural code of the Philippines.

Newton – A unit of force. It is a force that when applied to a

body having a mass of one kilogram, gives the body an acceleration

of one meter per second ever second.

Shear - typically denotes a force that acts perpendicular to the

length of a beam or a column (often referred to as “beam shear”)

or vertically in a slab.

Shear Walls - walls used for structural support but not

structurally joined or enclosed at the ends (except by breakaway


walls). Shear walls are parallel or nearly parallel, to the flow

of the water and can be used in any flood zone.

Method of Research

To develop the analysis and design needed in this study, the

approach taken by the researcher are as follows:

• Determination of the scope and limit of the topic.

• Research and gathering of related documents and

information from an agency or company related to the

research.

• Site visitation.

• Consultation of persons with knowledge regarding the

subject matter.

• Plan and conceptualize on how to develop and improve an

upright analysis and design of the study.

• Develop the planned and conceptualized analysis and

design.

• Use of Excel Program and BIM to develop the needed

analysis and design.


CHAPTER II

RELATIVE LITERATURE AND STUDIES

This chapter presents the various related literature and

studies that should provide the researcher with a broader

theoretical knowledge and information that may carry out this

study.

Foundation:

Foundation is the most important aspect of a structure. It is

the base of the entire structure. Even the word “foundation” has

made its way into popular culture; it is how we describe one’s

character, morals, and the basis of their ideas. If one’s

foundation is weak, everything else built upon it suffers. Without

a solid foundation, what would a structure look like?

Today’s foundations are generally comprised of an intricate

system of steel pilings or concrete piers–depending on the size of

the structure, the soil beneath the foundation, and other factors.

These projects have not always been the intricate systems that
they are now; when homes were first built, they–and their

foundations–were much simpler than they are today.

A firm foundation, we are told, is essential to building a

structure which lasts. Without a foundation, a structure would

sink into the soil.

Location:

Calapan, officially the City of Calapan, or referred simply

as Calapan City is a 3rd class city and the capital of the province

of Oriental Mindoro, Philippines. The city has an area of 250.06

km2 (96.55 sq mi) and is composed of 62 barangays of which 22 are

classified as urban and 40, rural. According to the 2015 census,

it has a population of 133,893 people. Barangay Kanagawa is the

most populated barangay with 10,570 residents. Followed by

barangay Lumang Bayan with a total of 4,965 people according to

2015 Census. Brgy Bucayao has 2,667 total population which

contributes 2% of the total population of the Calapan City.

Elevated building is perfect for Bucayao for gatherings.

Barangay Bucayao is an ideal location for the proposed multipurpose

elevated building for it is at the city of the province and easily

accessible for other municipality agencies. But aside from

gatherings and such events, it can also serve as an evacuation for


emergency purposes. Flood frequently occurs in Brgy Bucayao.

According to Mrs. Theresita Reyes, a resident of Sitio Quatro

Barangay Bucayao for 10 years and a barangay official, there is a

gabion constructed along blank river which makes the river overflow

in the barangay during whenever there is a heavy rainfall. And

another resident was interviewed, Mr. Gregorio Mercado, a barangay

kagawad and resident of Sitio Tres of the barangay for 34 years

said that during flood almost ¾ of the population is affected. The

flood ranges from 3 feet to 7 feet.

Flood Forecast/Report:

All datas provided about the flood reports of the area came

from the City Public Safety Department of Calapan City.

August 7, 2012

FLOODED BARANGAYS DUE TO HEAVY RAINS

As of August 7, 2012

Below are the informations gathered by this department:

Barangay Gutad was hit again by severe flooding affecting 400

families.
Sitio Abaton, Barangay Parang was also affected by flooding

affecting 20 families.

Barangay Bucayao reported 5 families evacuated in the Elementary

School and Evacuation Center.

December 6-9, 2014

Typhoon “RUBY”

On December 6-9, 2014 (Saturday-Tuesday) Members of the City

Disaster Risk Reduction Management Council of the City of Calapan had

an Emergency Meeting regarding plan of action RE: Typhoon RUBY.

On the 8th of December 2014, Calapan City experienced heavy rains

resulting to moderate to high flooding in identified flood prone areas

The City First Responders were notified and convene at the City

Public Safety Office - Center for Operations in Disaster and Emergency.

They were deployed at Brgy. Bucayao, Brgy. Sta. Rita and Brgy.Gutad

respectively.

A pre-emptive and force evacuation was done by the City Disaster

Risk Reduction Management Office thru the cooperation of the residents

of Brgy. Navotas, Maidlang, Gutad, Lazareto, Ibaba West, Ibaba East,

Buhuan, Wawa, Pachoca, Tibag, Salong, San Antonio, Silonay, Sapul,

Lumangbayan, Calero, Bayanan I, Balite, Sta. Cruz, Guinobatan, Mahal na

Pangalan, Pachoca, Suqui, Camilmil, Bucayao, Ilaya, Tawiran, Sta.

Isabel, Tawagan, Lalud, Comunal, Sta. Rita, San Vicente East, San Vicente
North, Puting Tubig and Brgy.Gutad in coordination with the Barangay

Officials.

The dike located at Brgy. Del Pilar, Naujan Oriental Mindoro was

monitored and assessed.

The accounted evacuees were estimated for about 7,000 individuals

from different barangays. Most of the evacuees were residents of coastal

barangays.

October 12, 2017

Tropical Depression Maring and Typhoon Lannie

(Report as of 09122017 1200hr)

The CDRRMO conducted monitoring to the low lying areas of

Calapan specifically ZONE 10 which includes Brgy. Buhuan, Brgy.

Sta. Cruz, Brgy. Nag-Iba I, Brgy. Nag-iba II, Brgy. Gutad, Brgy.

Navotas and Brgy. Maidlang respectively and found no significant

rise in water level in the said areas. CDRRMO also conducted

monitoring at Brgy. Bucayao, Brgy. Patas, Brgy. Personas and Brgy.


Canubing II with the same assessment. No significant rise in water

level in the following river systems such as: Bucayao River,

Pangalaan River, Mag-asawang Tubig River and Bucayao River (Sitio

B3).

July 22-23, 2018

Tropical Depression “Josie”

On July 22-23, 2018 the Island of Mindoro had an orange

rainfall warning due to Habagat (Southwest Monsoon) brought about

by Typhoon Josie. These heavy rains caused flooding to low lying

communities around the city. Brgy. Bucayao was affected and the

national highway was closed to traffic at around 10:00 pm of July

22, 2018 which caused passengers in and out of the Island of

Mindoro specifically Mindoro Oriental to be stranded. Brgy. Nag-

Iba I and Nag-Iba II experienced a chest high to man deep flooding

in some sitios.Brgu Gutad was under a thigh high deep flooding.

The construction of the bridge in Nag-Iba II was affected and a

damaged to the detour bridge was noted. Brgy. Buhuan, Panggalaan

and some areas of Sta. Cruz were also affected by the flooding. It

was also reported that the protection dike along Brgy. Comunal and

Brgy. Del Pilar of the Municipality of Naujan had its critical

level. Also noted was the agricultural damage specially rice

fields.
CHAPTER III

ANALYSIS AND DESIGN PROCEDURE

The Structure: General

Immediately after all materials to be used in the project

have passed the minimum testing requirements based on the standard

specifications for DPWH, the manner of operation in this particular

project shall have the following sequence:

• Mobilization shall consist of mobilization of equipment and

manpower, materials and other items that shall be use in the

implementation of the project.

Demobilization follows only after the project was

finally accepted and the surroundings are properly cleaned.

• Other general requirements shall be provided by the

contractor and shall maintain such offices, stores, workshops

latrines and messing accommodations as are necessary. These

should be located in the contractor’s compound, distinct and

separate from engineer's compound. The dimensions and layout


of the buildings and places shall be subject to the approval

of the project engineer. The contractor shall provide and

maintain throughout the duration of the contract.

• Structure excavation shall consist of the necessary

excavation for foundation of bridges, culverts, underdrains

and other structures provided in accordance with these

specifications and in close conformity with the plans or as

established by the engineer.


CHAPTER IV

COMPUTATIONS

Analysis and Design of Purlin

▪ DEAD LOAD

Dead loads on purlin include:

1. Self-weight of C3x6 member

2. Roofing Material (corrugated roofing sheet)

Dead load due to Self-weight of C3x6 member

Dead load due to Roofing Materials

Component Minimum Design Tributary Uniform Member

Dead load Width Dead Load

(kPa) (m) (KN/m)


Corrugated

Roofing Sheet 0.12 0.630 .0756

▪ Live Load
For the computation of the Live Load, the researcher

assumed that the only live load present in the structure is the

maintenance. The total live load assumed by the researcher is 1

KN/m.

Roof Live load due to Roofing Materials

Component Minimum Design Purlins Uniform Member

Dead load Spacing Dead Load

(kPa) (m) (KN/m)

Corrugated

Roofing Sheet 1 0.63 .3906


▪ WIND LOAD
For the simplicity and more conservative calculation, the

zone of purlin with the highest member load shall be carried

over to the zone with lower member load and one purlin member

is analyzed as to be applied for other purlins.

Wind load Case 1 (Positive)


Wind load Case 2 (Suction)

Analysis and Design of Truss

▪ Dead load

Dead loads on truss include:

1. Self-weight of member L404010 and L404012

2. Support Reaction of Purlins

Self-weight of member L404010 and L404012


Support Reaction on Purlins

Roof live load

Live Load
For the computation of the Live Load, the researcher assumed that

the only live load present in the structure is the maintenance.

The total live load assumed by the researcher is 1 KN/m.

Roof live load


Wind load

Windward Quarter Wind Load

Center Half Wind Load

Leeward Quarter Wind Load


FRAME A
FIRST FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 12.48 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 4 10 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 12.48)+ 0 = 44.1792 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 40 75.300 kN
282.079 kN
(frame span) ÷ 20 m
14.104 kN/m
+ 10%
UNIFORM LOAD: 15.514 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME B
FIRST FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 31 4
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 24.96 1 24.96
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 15 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 24.96)+ 25 = 113.3184 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 60 = 190.800 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
339.518 kN
(frame span) ÷ 20 m
16.976 kN/m
+ 10%
UNIFORM LOAD: 18.674 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME E
FIRST FLOOR LEVEL

FRAME SPAN 5m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 2.9
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 6.246 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 0 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 2.9 = 5.133 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 6.246)+ 0 = 22.11084 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 0 = 0.000 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
27.244 kN
(frame span) ÷ 2.9 m
9.394 kN/m
+ 10%
UNIFORM LOAD: 10.334 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME G
FIRST FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 25.008 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 25.01)+ 0 = 88.52832 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
251.128 kN
(frame span) ÷ 20 m
12.556 kN/m
+ 10%
UNIFORM LOAD: 13.812 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME H
FIRST FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 12.504 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 4 10 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 12.5 )+ 0 = 44.26416 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 40 75.300 kN
282.164 kN
(frame span) ÷ 20 m
14.108 kN/m
+ 10%
UNIFORM LOAD: 15.519 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME 1
FIRST FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 12.514 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 4 10 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.08 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 12.5 )+ 0 = 44.30098 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.08 • 40 75.300 kN
282.201 kN
(frame span) ÷ 20 m
14.110 kN/m
+ 10%
UNIFORM LOAD: 15.521 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME 2
FIRST FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 25.029 1 25.0288
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 12.6 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.08 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 25 )+ 25 = 113.6308 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 50.4 = 160.272 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.08 • 0 0.000 kN
309.303 kN
(frame span) ÷ 20 m
15.465 kN/m
+ 10%
UNIFORM LOAD: 17.012 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME 4
FIRST FLOOR LEVEL

FRAME SPAN 12.6 m


UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 12.6
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 15.888 1 15.888
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 0 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.08 • 12.6 = 22.302 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 15.9 )+ 16 = 72.13152 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 0 = 0.000 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.08 • 0 0.000 kN
94.434 kN
(frame span) ÷ 12.6 m
7.495 kN/m
+ 10%
UNIFORM LOAD: 8.244 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME 5
FIRST FLOOR LEVEL

FRAME SPAN 7.4 m


UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 7.4
t (m) Area (m^2)P-factor(Kpa) Partition Load
SLAB
0.15 12.256 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 0 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0 • 4 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0 • 2 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0 • 7 = 13.098 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0 • # )+ 0 = 43.38624 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0 • 0 = 0.000 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0 • 0 0.000 kN
56.484 kN
(frame span) ÷ 7.4 m
7.633 kN/m
+ 10%
UNIFORM LOAD: 8.396 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME 8
FIRST FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 25.029 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 12.6 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.08 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 25 )+ 0 = 88.601952 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 50.4 = 160.272 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.08 • 0 0.000 kN
284.274 kN
(frame span) ÷ 20 m
14.214 kN/m
+ 10%
UNIFORM LOAD: 15.635 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME 9
FIRST FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 12.514 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 4 10 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.08 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 12.5 )+ 0 = 44.30098 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.08 • 40 75.300 kN
282.201 kN
(frame span) ÷ 20 m
14.110 kN/m
+ 10%
UNIFORM LOAD: 15.521 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME A
SECOND FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 12.48 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 4 10 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 12.48)+ 0 = 44.1792 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 40 75.300 kN
282.079 kN
(frame span) ÷ 20 m
14.104 kN/m
+ 10%
UNIFORM LOAD: 15.514 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME B
SECOND FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 41 3
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 24.96 1 24.96
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 15 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 24.96)+ 25 = 113.3184 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 60 = 190.800 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
339.518 kN
(frame span) ÷ 20 m
16.976 kN/m
+ 10%
UNIFORM LOAD: 18.674 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME E
SECOND FLOOR LEVEL

FRAME SPAN 5m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 2.9
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 6.246 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 0 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 2.9 = 5.133 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 6.246)+ 0 = 22.11084 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 0 = 0.000 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
27.244 kN
(frame span) ÷ 2.9 m
9.394 kN/m
+ 10%
UNIFORM LOAD: 10.334 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME G
SECOND FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 25.008 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 25.01)+ 0 = 88.52832 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
251.128 kN
(frame span) ÷ 20 m
12.556 kN/m
+ 10%
UNIFORM LOAD: 13.812 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME H
SECOND FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 12.504 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 4 10 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 12.5 )+ 0 = 44.26416 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 40 75.300 kN
282.164 kN
(frame span) ÷ 20 m
14.108 kN/m
+ 10%
UNIFORM LOAD: 15.519 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME 1
SECOND FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 12.514 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 4 10 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 12.51)+ 0 = 44.30098 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 40 75.300 kN
282.201 kN
(frame span) ÷ 20 m
14.110 kN/m
+ 10%
UNIFORM LOAD: 15.521 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME 2
SECOND FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 25.029 1 25.0288
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 12.6 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 25.03)+ 25 = 113.6308 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 50.4 = 160.272 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
309.303 kN
(frame span) ÷ 20 m
15.465 kN/m
+ 10%
UNIFORM LOAD: 17.012 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME 4
SECOND FLOOR LEVEL

FRAME SPAN 12.6 m


UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 12.6
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 15.888 1 15.888
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 0 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 12.6 = 22.302 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 15.89)+ 16 = 72.13152 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 0 = 0.000 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
94.434 kN
(frame span) ÷ 12.6 m
7.495 kN/m
+ 10%
UNIFORM LOAD: 8.244 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME 5
SECOND FLOOR LEVEL

FRAME SPAN 7.4 m


UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 3 4
Area (m^2) Span (m)
BEAM
0.075 7.4
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 12.256 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 0 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 1.5 = 8.850 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 7.4 = 13.098 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 12.26)+ 0 = 43.38624 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 0 = 0.000 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
56.484 kN
(frame span) ÷ 7.4 m
7.633 kN/m
+ 10%
UNIFORM LOAD: 8.396 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 8.850 kN


FRAME 6
SECOND FLOOR LEVEL

FRAME SPAN 12.6 m


UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 12.6
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 15.888 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 0 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 12.6 = 22.302 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 15.89)+ 0 = 56.24352 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 0 = 0.000 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
78.546 kN
(frame span) ÷ 12.6 m
6.234 kN/m
+ 10%
UNIFORM LOAD: 6.857 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME 8
SECOND FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 25.029 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 12.6 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 0 0 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 25.03)+ 0 = 88.60195 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 50.4 = 160.272 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 0 0.000 kN
284.274 kN
(frame span) ÷ 20 m
14.214 kN/m
+ 10%
UNIFORM LOAD: 15.635 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME 9
SECOND FLOOR LEVEL

FRAME SPAN 20 m
UNIT WEIGHT OF CONCRETE 23.6 kN/m^3
UNIT WEIGHT OF MASONRY 21.2 kN/m^3
UNIT WEIGHT OF GLASS 25.1 kN/m^3
Area (m^2) L1(m) L2(m)
COLUMN
0.25 4 3
Area (m^2) Span (m)
BEAM
0.075 20
t (m) Area (m^2) P-factor(Kpa) Partition Load
SLAB
0.15 12.514 0 0
t (m) h(m) span(m) area of opening (m^2)
WALL 150
0.15 4 10 0
t (m) h(m) span(m) area of opening (m^2)
WALL 200
0.2 0 0 0
t (m) h(m) span(m) area of opening (m^2)
GLASS
0.075 4 10 0

COLUMN (F) = unit weight•Area•[(L1/2)+(L2/2)]


COLUMN(F) = 23.6 • 0.25 • 3.5 = 20.650 kN
COLUMN (H) = unit weight•Area•[(L1/2)+(L2/2)]
COLUMN(H) = 23.6 • 0.25 • 2 = 11.800 kN
BEAM = unit weight•area•span
BEAM = 23.6 • 0.075 • 20 = 35.400 kN
SLAB =[ (unit weight•t•area) + partition load]
SLAB =( 23.6 • 0.15 • 12.51)+ 0 = 44.30098 kN
WALL 100 = unit weight•t•[h(span)-area of opening]
WALL 100 = 21.2 • 0.15 • 40 = 127.200 kN
WALL 150 = unit weight•t•[h(span)-area of opening]
WALL 150 = 21.2 • 0.2 • 0 = 0.000 kN
GLASS = unit weight•t•[h(span)-area of opening]
GLASS = 25.1 • 0.075 • 40 75.300 kN
282.201 kN
(frame span) ÷ 20 m
14.110 kN/m
+ 10%
UNIFORM LOAD: 15.521 kN/m

CONCENTRATED LOAD (FULL): 20.650 kN

CONCENTRATED LOAD (HALF): 11.800 kN


FRAME A
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 12.48 47.424
Total Liveload 47.424
Beam Span (m) 20

Live Load (kN/m) 2.38

FRAME B
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 15.606 59.3028
Restroom 1.9 3.126 5.9394
Stage Area 7.2 4.689 33.7608
Staircase 4.8 1.563 7.5024
Total Liveload 106.5054
Beam Span (m) 20

Live Load (kN/m) 5.33

FRAME E
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 6.246 23.7348
Total Liveload 23.7348
Beam Span (m) 5

Live Load (kN/m) 4.75


FRAME G
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Receiving area and Lobby 4.8 9.378 45.0144
Corridor 3.8 15.63 59.394
Total Liveload 104.4084
Beam Span (m) 20

Live Load (kN/m) 5.23

FRAME H
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 12.504 47.5152
Total Liveload 47.5152
Beam Span (m) 20

Live Load (kN/m) 2.38


FRAME 1
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 14.072 53.4736
Total Liveload 53.4736
Beam Span (m) 20

Live Load (kN/m) 2.68

FRAME 2
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 20.2 76.76
Restroom 1.9 3.128 5.9432
Movable Seats 4.8 4.816 23.1168
Total Liveload 105.82
Beam Span (m) 20

Live Load (kN/m) 5.30

FRAME 4
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Movable Seats 4.8 9.632 46.2336
Stage Area 7.2 3.128 22.5216
Restroom 1.9 3.128 5.9432
Storage 1.9 1.688 3.2072
Total Liveload 77.9056
Beam Span (m) 12.6

Live Load (kN/m) 6.19


FRAME 5
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 12.256 46.5728
Total Liveload 46.5728
Beam Span (m) 7.4

Live Load (kN/m) 6.30

FRAME 6
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Movable Seats 4.8 9.631 46.2288
Stage Area 7.2 3.128 22.5216
Storage 1.9 1.688 3.2072
Total Liveload 71.9576
Beam Span (m) 12.6

Live Load (kN/m) 5.72

FRAME 8
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 15.512 58.9456
Movable Seats 4.8 6.256 30.0288
Storage 1.9 1.688 3.2072
Total Liveload 92.1816
Beam Span (m) 20

Live Load (kN/m) 4.61


FRAME 9
FIRST FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 14.072 53.4736
Total Liveload 53.4736
Beam Span (m) 20

Live Load (kN/m) 2.68


FRAME A
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 12.48 47.424
Total Liveload 47.424
Beam Span (m) 20

Live Load (kN/m) 2.38

FRAME B
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 15.606 59.3028
Restroom 1.9 3.126 5.9394
Stage Area 7.2 4.689 33.7608
Staircase 4.8 1.563 7.5024
Total Liveload 106.5054
Beam Span (m) 20

Live Load (kN/m) 5.33

FRAME E
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 6.246 23.7348
Total Liveload 23.7348
Beam Span (m) 5

Live Load (kN/m) 4.75


FRAME G
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 15.63 59.394
Total Liveload 59.394
Beam Span (m) 20

Live Load (kN/m) 2.97

FRAME H
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 12.504 47.5152
Total Liveload 47.5152
Beam Span (m) 20

Live Load (kN/m) 2.38


FRAME 1
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 14.072 53.4736
Total Liveload 53.4736
Beam Span (m) 20

Live Load (kN/m) 2.68

FRAME 2
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 20.2 76.76
Movable Seats 4.8 4.816 23.1168
Total Liveload 99.8768
Beam Span (m) 20

Live Load (kN/m) 5.00

FRAME 4
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Movable Seats 4.8 9.632 46.2336
Stage Area 7.2 3.128 22.5216
Storage 1.9 1.688 3.2072
Total Liveload 71.9624
Beam Span (m) 12.6

Live Load (kN/m) 5.72


FRAME 5
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 12.256 46.5728
Total Liveload 46.5728
Beam Span (m) 7.4

Live Load (kN/m) 6.30

FRAME 6
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Movable Seats 4.8 9.631 46.2288
Stage Area 7.2 3.128 22.5216
Storage 1.9 1.688 3.2072
Total Liveload 71.9576
Beam Span (m) 12.6

Live Load (kN/m) 5.72

FRAME 8
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 15.512 58.9456
Movable Seats 4.8 6.256 30.0288
Storage 1.9 1.688 3.2072
Total Liveload 92.1816
Beam Span (m) 20

Live Load (kN/m) 4.61


FRAME 9
SECOND FLOOR LEVEL

Live Load
Live Load Area
Occupancy Factor x
Factor (kPa) (m^2)
Area
Corridor 3.8 14.072 53.4736
Total Liveload 53.4736
Beam Span (m) 20

Live Load (kN/m) 2.68


PURLINS
By: Stephanne Jane L. Montoya

DEAD LOAD COMPUTATION


1. SELFWEIGHT 1 kPa

2. CORRUGATED ROOFING SHEET

LOAD(kN/m^3) x TRIBUTARY WIDTH

0.12 x 0.63 = 0.0756 kn/m^2

3. PURLINS SPACING = 0.63 m

LIVE LOAD COMPUTATION

1. CORRUGATED ROOFING SHEET 0.62 kPa

TOTAL LOAD = LIVE LOAD x PURLINS SPACING

0.62 x 0.63 = 0.3906 kn/m^2

WIND LOAD COMPUTION

PURLINS SPACING = 0.63 m


TRUSS SPACING = 2.6 m

EFFECTIVE WIND AREA = 1.638 m2


ZONE
BY INTERPOLATION : EFFECTIVE WIND AREA 1 2
1 1.20 & -1.90 1.20 & -3.32
2 1.09 & -1.85 1.09 & -3.04

2 −1 1.638 −1
= = 1.13
1.09 −1.20 𝑥−1.20

2 −1 1.638 −1
= = -1.868
−1.85 −(−1.90) 𝑥−(−1.90)

2 −1 1.638 −1
= = 1.13
1.09 −1.20 𝑥−1.20

2 −1 1.638 −1
= = -3.141
−3.04 −(−3.32) 𝑥−(−3.32)

WIND LOAD 1

1.13 x PURLIN SPACING


1.13 x 0.63 = 0.712 kn/m^2

ZONE 1 & 2 ARE SAME VALUE

WIND LOAD 2

-1.868 x 0.63 = -1.177 kn/m^2


-3.141 x 0.63 = -1.9788 kn/m^2
MAIN TRUSS
By: Stephanne Jane L. Montoya

DEAD LOAD COMPUTATION


1. SELFWEIGHT 1 kPa

2. PURLINS
TOTAL WEIGHT / SPACING / LENGTH * TRUSS SPACING

1.274 / 0.63 / 14.6 x 2.6 = 0.361 kn/m^2

LIVE LOAD COMPUTATION


For the computation of the Live Load, the researcher assumed that the only live load present in the structure is the
maintenance. The total live load assumed by the researcher is 1 KN/m.

WIND LOAD COMPUTATION


TRUSS SPACING 2.62 m
250 kph
EFFECTIVE WIND AREA = LENGTH OF TRUSS x TRUSS SPACING
14.6 x 2.6 = 37.96 m2
ZONE
EFFECTIVE WIND AREA 1 2
0.85 0.85
9.5
-1.72 -2.44

WIND LOAD 1

0.85 x 2.6 = 2.21 kn/m^2

ZONE 1 & 2 ARE SAME VALUES

WIND LOAD 2

-1.72 x 2.6 = -4.472 kn/m^2

-2.44 x 2.6 = -6.344 kn/m^2


_______________________________________________________________________

TOP CHORD

Beam No. 131 To 146


Steel Member L4X4X3/4

Axial 120,414 N Shear 4,742 N

steel column and plate properties weld type properties


Fy 248.00 MPa Fy 345.00 MPa
Fu 400.00 MPa Fu 400.00 MPa

steel type used for column and plate: A36


electrode used for welding: E60XX
size of fillet weld (w): 12 mm
Perimeter of W Section (L): 508.000 mm

computed shear stress on welds: allowable shear stress on welds:


fv = P/(0.707w)L Fv = 0.3Fu = 120.00 MPa

fv = 1.10 MPa < 120.00 MPa adequate

computed shear stress on plate: allowable shear stress on plate:


fv = P/wL Fv = 0.4Fy = 99.20 MPa

fp = 0.78 MPa < 99.20 MPa adequate

computed shear stress on column: allowable shear stress on column:


fv = P/wL Fv = 0.4Fy = 99.20 MPa

fp = 19.75 MPa < 99.20 MPa adequate

computed tensile stress on welds: allowable tensile stress on welds:


ft = P/(0.707w)L Ft = 0.6Fy = 148.80 MPa

ft = 27.94 MPa < 148.80 MPa adequate

computed tensile stress on plates: allowable tensile stress on plates:


ft = P/wL Ft = 0.6Fy = 148.80 MPa

ft = 19.75 MPa < 148.80 MPa adequate

Therefore, the fillet weld is ADEQUATE

________________________________________________________
_______________________________________________________________________

BOTTOM CHORD

Beam No. 35 To 48 147 148


Steel Member L4X4X3/4

Axial 97,301 N Shear 1,133 N

steel column and plate properties weld type properties


Fy 248.00 MPa Fy 345.00 MPa
Fu 400.00 MPa Fu 400.00 MPa

steel type used for column and plate: A36


electrode used for welding: E60XX
size of fillet weld (w): 12 mm
Perimeter of W Section (L): 508.000 mm

computed shear stress on welds: allowable shear stress on welds:


fv = P/(0.707w)L Fv = 0.3Fu = 120.00 MPa

fv = 0.26 MPa < 120.00 MPa adequate

computed shear stress on plate: allowable shear stress on plate:


fv = P/wL Fv = 0.4Fy = 99.20 MPa

fp = 0.19 MPa < 99.20 MPa adequate

computed shear stress on column: allowable shear stress on column:


fv = P/wL Fv = 0.4Fy = 99.20 MPa

fp = 15.96 MPa < 99.20 MPa adequate

computed tensile stress on welds: allowable tensile stress on welds:


ft = P/(0.707w)L Ft = 0.6Fy = 148.80 MPa

ft = 22.58 MPa < 148.80 MPa adequate

computed tensile stress on plates: allowable tensile stress on plates:


ft = P/wL Ft = 0.6Fy = 148.80 MPa

ft = 15.96 MPa < 148.80 MPa adequate

Therefore, the fillet weld is ADEQUATE

________________________________________________________
_______________________________________________________________________

WEB MEMBERS

Beam No. 17 To 33 66 To 81
Steel Member L4X4X5/8

Axial 70,668 N Shear 744 N

steel column and plate properties weld type properties


Fy 248.00 MPa Fy 345.00 MPa
Fu 400.00 MPa Fu 400.00 MPa

steel type used for column and plate: A36


electrode used for welding: E60XX
size of fillet weld (w): 12 mm
Perimeter of W Section (L): 508.000 mm

computed shear stress on welds: allowable shear stress on welds:


fv = P/(0.707w)L Fv = 0.3Fu = 120.00 MPa

fv = 0.17 MPa < 120.00 MPa adequate

computed shear stress on plate: allowable shear stress on plate:


fv = P/wL Fv = 0.4Fy = 99.20 MPa

fp = 0.12 MPa < 99.20 MPa adequate

computed shear stress on column: allowable shear stress on column:


fv = P/wL Fv = 0.4Fy = 99.20 MPa

fp = 11.59 MPa < 99.20 MPa adequate

computed tensile stress on welds: allowable tensile stress on welds:


ft = P/(0.707w)L Ft = 0.6Fy = 148.80 MPa

ft = 16.40 MPa < 148.80 MPa adequate

computed tensile stress on plates: allowable tensile stress on plates:


ft = P/wL Ft = 0.6Fy = 148.80 MPa

ft = 11.59 MPa < 148.80 MPa adequate

Therefore, the fillet weld is ADEQUATE

________________________________________________________
DESIGN OF COLUMN

Mu (top) 272 kN-m main bars 20 mm


Mu (bottom) 272 kN-m stirrups 12 mm
Pu 520.111 kN lu 3,000 mm
M1b 271.717 kN-m h 600 mm
M2b 271.717 kN-m b 600 mm
φ 0.65 r 180 mm
k 0.65 fy 415 Mpa
fc' 27.60 Mpa

Check the SLENDERNESS EFFECT:


(If the condition is TRUE, it is therefore SHORT COLUMN)

10.833 < 22.000

Since the condition is : TRUE

DESIGN AS SHORT COLUMN

The axial load capacity of the tied column is given by:


Pu = φ 0.80 [0.85 fc’ (Ag – Ast) + fy Ast]

where Ag = 360,000.00 sq.mm.


φ = 0.65

520.111 (1000) = 0.65 (0.80) [0.85 (27.6) (360000 – Ast) + 415 (Ast)]

Solving for the area of steel, Ast: [0.01 Ag ≤ Ast ≤ 0.06 Ag ]


Ast = -19,015.65 sq.mm.

Ast / Ag = -0.05282 not OK! Use Ast = 0.01 Ag

using 20 - mm main bars: Spacing of ties: using 12 - mm stirrups


2
Ast = 3,600.00 mm smallest of: 16 x dbar = 320
2
Ab = 314.16 mm 48 x dtie = 576
N = 11.46 say 12 pc/s. least column dimension = 600

Therefore: USE 12 - 20-mm 𝛟 main bars. USE 12-mm 𝛟 ties at 320 mm o.c.
DESIGN OF BEAM (1ST FLOOR LEVEL) For DOUBLY REINFORCED BEAMS:
Assume fs = Fy and fs' = Fy:
(20m BEAMS)
As = As,max + As'
GIVEN:
b 250 mm Mu 107.958 kN-m Mu1 = Mu,cap = 92.100 kN-m
h 300 mm 𝛟 0.90 Mu2 = Mu - Mu1 = 15.858 kN-m
clear cover 40 mm β1 0.85 Mu2 = φ As' Fy (d - d')
d 242 mm Vu 94.581 kN 15.858 (10^6) = 0.9 (As') (415) (242 - 59)
d' 59 mm 𝛟 0.75 As' = 232.010 sq.mm.
Fy 415 Mpa Tension Bars 16 - mm φ
fc' 27.6 Mpa Comp. Bars 16 - mm φ As = 1,477.893 sq.mm.
L 20000 mm Stirrups 10 - mm φ

DUCTILITY:
STEEL RATIO: ρb 0.02840 Maximum/Minimum Steel Ratio:
ρmax 0.02059
ρmin 0.00337 ρmax' = ρmax + ρ'
ρmax = 0.02059 ρ = 0.02443 > ρmax' = 0.02442
check if SRB or DRB: ρ' = As' / b d =ρ' = 0.00383 not OK! (Beam is over-reinforced!)

As max = ρmax b d ρmax' = 0.02442


= 0.02059 x 250 x 242 ρ = As / b d ρ = 0.02443 > ρmin = 0.00337
2
As max = 1,245.883 mm ρ = 0.02443 OK!

Mu cap = φ As max Fy (d - a/2) Check assumption that fs = Fy and fs' = Fy: Єy = Fy / Es = 0.00208
from the Strain Diagram,
a= As max Fy Єs = 0.003 (d - c) / c Єs' = 0.003 (c - d') / c
0.85 fc' b a = As Fy / 0.85 fc' b
a= 88.16 mm a = 88.157 mm
c = a / β1
Mu cap = 92.100 kN-m c = 103.714 mm

NOTE: Mu cap < Mu Єs = 0.00400 > Єy = 0.00208 OK! Assumption is correct!


Єs' = 0.00129 < Єy = 0.00208 not OK! Solve for fs'!
Analyze beam as DRB!
solving fs' using QUADRATIC EQN: fs' = 110.07 MPa
REINFORCEMENT:
TENSION: using 16 - mm φ rebars COMPRESSION: using 16 - mm φ rebars
As = 1,477.893 As' = 874.74
Ab = 201.062 Ab = 201.062
N= 7.35 say 8 pc/s. N= 4.35 say 5 pc/s.

Therefore: USE 8 - 16-mm 𝛟 rebars. Therefore: USE 5 - 16-mm 𝛟 rebars.


ld 12 F y α β λ
DEVELOPMENT LENGTH: db
= Requirements:
20 fc'
a. Clear spacing of bars being developed > [db = 16 mm] OK!
Reinforcement Location Factor, α 1.3 clear spacing = 250 - 2(50 + 10 + 16) = 98 mm
Coating Factor, β 1.0 b. Clear cover = 50 mm > [db = 16 mm] OK!
Lightweight Aggregate Factor, λ 1.0 αβ = 1.3 < 1.7 c. STIRRUPS according to ACI Code.
Diameter of the rebar, db 16 OK!
As REQD / As PROV 0.92 ld = 12 (415) (1.3) (1.0) (1.0) (0.92) (16)
20 √27.6
ld = 905.80 mm > 300 mm OK!
SHEAR
Half of SHEAR DIAGRAM:
Vu = 94.581 kN Vu 94.581
Vud = 92.292 kN Vud 92.292

φ Vc = 39.730 kN φ Vc 39.730

0.5 φ Vc = 19.865 kN
0.5 φ Vc 19.865

A B C D E

Vu > φ Vc 0.242 9.758

Provide STIRRUPS! 5.799 4.201

7.899 2.101

DESIGN OF STIRRUPS
From B - C: Design stirrups. using 10 - mm φ STIRRUPS:
From C - D: Provide minimum stirrups. Ab = 78.540 sq.mm
From D - E: No stirrups required. Av = 2 Ab = 157.080 sq.mm

Maximum Spacing, Smax: Vu = Vud


Vs = (Vu - φ Vc)/ φ ⅔ [√fc’] bw d = 211.894 kN
Vs = 70.083 kN ⅓ [√fc’] bw d = 105.947 kN

Vs = 70.083 kN < ⅔ [√fc’] bw d = 211.894 kN OK!

Since: Vs = 70.083 kN < ⅓ [√fc’] bw d = 105.947 kN

Smax, smallest of: a. d/2 = 121 mm Smax = 121.000 mm


b. 600 mm
c. 3 Av Fy/bw = 782.257 mm

@ x = 0.242 m (from support face): Vux = 92.292 kN

S= φ Av Fy d = 225.099 mm (S > Smax) not OK!


Vux - φ Vc use S = Smax = 121.000 mm

NOTE: Assume that only two spacings are required between distance B to C.

@ x = 0.242 + (5.799 - 0.242)/2 = 3.021 m (from support face): Vux = Vud

S= φ Av Fy d = 225.099 mm (S > Smax) not OK!


Vux - φ Vc use S = Smax = 121.000 mm

SKETCH

A B C D E

2 @ 121 mm No STIRRUPS required!


1 @ 50 mm 23 @ 121 mm 23 @ 121 mm 18 @ 121 mm
DESIGN OF BEAM (1ST FLOOR LEVEL) For DOUBLY REINFORCED BEAMS:
Assume fs = Fy and fs' = Fy:
(5m BEAMS)
As = As,max + As'
GIVEN:
b 250 mm Mu 104.558 kN-m Mu1 = Mu,cap = 92.100 kN-m
h 300 mm 𝛟 0.90 Mu2 = Mu - Mu1 = 12.458 kN-m
clear cover 40 mm β1 0.85 Mu2 = φ As' Fy (d - d')
d 242 mm Vu 65.641 kN 12.458 (10^6) = 0.9 (As') (415) (242 - 58)
d' 58 mm 𝛟 0.75 As' = 181.276 sq.mm.
Fy 415 Mpa Tension Bars 16 - mm φ
fc' 27.6 Mpa Comp. Bars 16 - mm φ As = 1,427.159 sq.mm.
L 5000 mm Stirrups 10 - mm φ

DUCTILITY:
STEEL RATIO: ρb 0.02840 Maximum/Minimum Steel Ratio:
ρmax 0.02059
ρmin 0.00337 ρmax' = ρmax + ρ'
ρmax = 0.02059 ρ = 0.02359 = ρmax' = 0.02359
check if SRB or DRB: ρ' = As' / b d =ρ' = 0.00300 OK! (Ductile)

As max = ρmax b d ρmax' = 0.02359


= 0.02059 x 250 x 242 ρ = As / b d ρ = 0.02359 > ρmin = 0.00337
2
As max = 1,245.883 mm ρ = 0.02359 OK!

Mu cap = φ As max Fy (d - a/2) Check assumption that fs = Fy and fs' = Fy: Єy = Fy / Es = 0.00208
from the Strain Diagram,
a= As max Fy Єs = 0.003 (d - c) / c Єs' = 0.003 (c - d') / c
0.85 fc' b a = As Fy / 0.85 fc' b
a= 88.16 mm a = 88.157 mm
c = a / β1
Mu cap = 92.100 kN-m c = 103.714 mm

NOTE: Mu cap < Mu Єs = 0.00400 > Єy = 0.00208 OK! Assumption is correct!


Єs' = 0.00132 < Єy = 0.00208 not OK! Solve for fs'!
Analyze beam as DRB!
solving fs' using QUADRATIC EQN: fs' = 108.64 MPa
REINFORCEMENT:
TENSION: using 16 - mm φ rebars COMPRESSION: using 16 - mm φ rebars
As = 1,427.159 As' = 692.50
Ab = 201.062 Ab = 201.062
N= 7.10 say 8 pc/s. N= 3.44 say 4 pc/s.

Therefore: USE 8 - 16-mm 𝛟 rebars. Therefore: USE 4 - 16-mm 𝛟 rebars.


ld 12 F y α β λ
DEVELOPMENT LENGTH: db
= Requirements:
20 fc'
a. Clear spacing of bars being developed > [db = 16 mm] OK!
Reinforcement Location Factor, α 1.3 clear spacing = 250 - 2(50 + 10 + 16) = 98 mm
Coating Factor, β 1.0 b. Clear cover = 50 mm > [db = 16 mm] OK!
Lightweight Aggregate Factor, λ 1.0 αβ = 1.3 < 1.7 c. STIRRUPS according to ACI Code.
Diameter of the rebar, db 16 OK!
As REQD / As PROV 0.89 ld = 12 (415) (1.3) (1.0) (1.0) (0.89) (16)
20 √27.6
ld = 874.70 mm > 300 mm OK!
SHEAR
Half of SHEAR DIAGRAM:
Vu = 65.641 kN Vu 65.641
Vud = 59.287 kN Vud 59.287

φ Vc = 39.730 kN φ Vc 39.730

0.5 φ Vc = 19.865 kN
0.5 φ Vc 19.865

A B C D E

Vu > φ Vc 0.242 2.258

Provide STIRRUPS! 0.987 1.513

1.743 0.757

DESIGN OF STIRRUPS
From B - C: Design stirrups. using 10 - mm φ STIRRUPS:
From C - D: Provide minimum stirrups. Ab = 78.540 sq.mm
From D - E: No stirrups required. Av = 2 Ab = 157.080 sq.mm

Maximum Spacing, Smax: Vu = Vud


Vs = (Vu - φ Vc)/ φ ⅔ [√fc’] bw d = 211.894 kN
Vs = 26.076 kN ⅓ [√fc’] bw d = 105.947 kN

Vs = 26.076 kN < ⅔ [√fc’] bw d = 211.894 kN OK!

Since: Vs = 26.076 kN < ⅓ [√fc’] bw d = 105.947 kN

Smax, smallest of: a. d/2 = 121 mm Smax = 121.000 mm


b. 600 mm
c. 3 Av Fy/bw = 782.257 mm

@ x = 0.242 m (from support face): Vux = 59.287 kN

S= φ Av Fy d = 604.982 mm (S > Smax) not OK!


Vux - φ Vc use S = Smax = 121.000 mm

NOTE: Assume that only two spacings are required between distance B to C.

@ x = 0.242 + (0.987 - 0.242)/2 = 0.615 m (from support face): Vux = Vud

S= φ Av Fy d = 604.982 mm (S > Smax) not OK!


Vux - φ Vc use S = Smax = 121.000 mm

SKETCH

A B C D E

2 @ 121 mm No STIRRUPS required!


1 @ 50 mm 4 @ 121 mm 4 @ 121 mm 7 @ 121 mm
DESIGN OF BEAM (2ND FLOOR LEVEL) For DOUBLY REINFORCED BEAMS:
Assume fs = Fy and fs' = Fy:
(20m BEAMS)
As = As,max + As'
GIVEN:
b 250 mm Mu 98.904 kN-m Mu1 = Mu,cap = 92.100 kN-m
h 300 mm 𝛟 0.90 Mu2 = Mu - Mu1 = 6.804 kN-m
clear cover 40 mm β1 0.85 Mu2 = φ As' Fy (d - d')
d 242 mm Vu 88.157 kN 6.804 (10^6) = 0.9 (As') (415) (242 - 58)
d' 58 mm 𝛟 0.75 As' = 99.005 sq.mm.
Fy 415 Mpa Tension Bars 16 - mm φ
fc' 27.6 Mpa Comp. Bars 16 - mm φ As = 1,344.888 sq.mm.
L 20000 mm Stirrups 10 - mm φ

DUCTILITY:
STEEL RATIO: ρb 0.02840 Maximum/Minimum Steel Ratio:
ρmax 0.02059
ρmin 0.00337 ρmax' = ρmax + ρ'
ρmax = 0.02059 ρ = 0.02223 = ρmax' = 0.02223
check if SRB or DRB: ρ' = As' / b d =ρ' = 0.00164 OK! (Ductile)

As max = ρmax b d ρmax' = 0.02223


= 0.02059 x 250 x 242 ρ = As / b d ρ = 0.02223 > ρmin = 0.00337
2
As max = 1,245.883 mm ρ = 0.02223 OK!

Mu cap = φ As max Fy (d - a/2) Check assumption that fs = Fy and fs' = Fy: Єy = Fy / Es = 0.00208
from the Strain Diagram,
a= As max Fy Єs = 0.003 (d - c) / c Єs' = 0.003 (c - d') / c
0.85 fc' b a = As Fy / 0.85 fc' b
a= 88.16 mm a = 88.157 mm
c = a / β1
Mu cap = 92.100 kN-m c = 103.714 mm

NOTE: Mu cap < Mu Єs = 0.00400 > Єy = 0.00208 OK! Assumption is correct!


Єs' = 0.00132 < Єy = 0.00208 not OK! Solve for fs'!
Analyze beam as DRB!
solving fs' using QUADRATIC EQN: fs' = 106.53 MPa
REINFORCEMENT:
TENSION: using 16 - mm φ rebars COMPRESSION: using 16 - mm φ rebars
As = 1,344.888 As' = 385.69
Ab = 201.062 Ab = 201.062
N= 6.69 say 7 pc/s. N= 1.92 say 2 pc/s.

Therefore: USE 7 - 16-mm 𝛟 rebars. Therefore: USE 2 - 16-mm 𝛟 rebars.


ld 12 F y α β λ
DEVELOPMENT LENGTH: db
= Requirements:
20 fc'
a. Clear spacing of bars being developed > [db = 16 mm] OK!
Reinforcement Location Factor, α 1.3 clear spacing = 250 - 2(50 + 10 + 16) = 98 mm
Coating Factor, β 1.0 b. Clear cover = 50 mm > [db = 16 mm] OK!
Lightweight Aggregate Factor, λ 1.0 αβ = 1.3 < 1.7 c. STIRRUPS according to ACI Code.
Diameter of the rebar, db 16 OK!
As REQD / As PROV 0.96 ld = 12 (415) (1.3) (1.0) (1.0) (0.96) (16)
20 √27.6
ld = 942.03 mm > 300 mm OK!
SHEAR
Half of SHEAR DIAGRAM:
Vu = 88.157 kN Vu 88.157
Vud = 86.024 kN Vud 86.024

φ Vc = 39.730 kN φ Vc 39.730

0.5 φ Vc = 19.865 kN
0.5 φ Vc 19.865

A B C D E

Vu > φ Vc 0.242 9.758

Provide STIRRUPS! 5.493 4.507

7.746 2.254

DESIGN OF STIRRUPS
From B - C: Design stirrups. using 10 - mm φ STIRRUPS:
From C - D: Provide minimum stirrups. Ab = 78.540 sq.mm
From D - E: No stirrups required. Av = 2 Ab = 157.080 sq.mm

Maximum Spacing, Smax: Vu = Vud


Vs = (Vu - φ Vc)/ φ ⅔ [√fc’] bw d = 211.894 kN
Vs = 61.725 kN ⅓ [√fc’] bw d = 105.947 kN

Vs = 61.725 kN < ⅔ [√fc’] bw d = 211.894 kN OK!

Since: Vs = 61.725 kN < ⅓ [√fc’] bw d = 105.947 kN

Smax, smallest of: a. d/2 = 121 mm Smax = 121.000 mm


b. 600 mm
c. 3 Av Fy/bw = 782.257 mm

@ x = 0.242 m (from support face): Vux = 86.024 kN

S= φ Av Fy d = 255.576 mm (S > Smax) not OK!


Vux - φ Vc use S = Smax = 121.000 mm

NOTE: Assume that only two spacings are required between distance B to C.

@ x = 0.242 + (5.493 - 0.242)/2 = 2.868 m (from support face): Vux = Vud

S= φ Av Fy d = 255.576 mm (S > Smax) not OK!


Vux - φ Vc use S = Smax = 121.000 mm

SKETCH

A B C D E

2 @ 121 mm No STIRRUPS required!


1 @ 50 mm 22 @ 121 mm 22 @ 121 mm 19 @ 121 mm

1
DESIGN OF BEAM (2ND FLOOR LEVEL) For SINGLY REINFORCED BEAMS:
Assume fs = Fy:
(5m BEAMS)
Mu = φ R b d^2 = 90.819 kN-m
GIVEN: solve for R:
b 250 mm Mu 90.819 kN-m R = Mu / φ b d^2 = 90.819 (10^6) / 0.9 (250) (242^2)
h 300 mm 𝛟 0.90 R = 6.892
clear cover 40 mm β1 0.85 ρ = 0.85 (fc'/Fy) [1 - √(1 - 2R/0.85 fc')]
d 242 mm Vu 61.649 kN ρ = 0.02023
d' 58 mm 𝛟 0.75
Fy 415 Mpa Tension Bars 16 - mm φ As = ρ b d
fc' 27.6 Mpa Comp. Bars 16 - mm φ As = 1,223.915 sq.mm.
L 5000 mm Stirrups 10 - mm φ

DUCTILITY:
STEEL RATIO: ρb 0.02840 Maximum/Minimum Steel Ratio:
ρmax 0.02059 ρ = 0.02023 < ρmax = 0.02059
ρmin 0.00337 OK! (Ductile)

check if SRB or DRB:


ρ = 0.02023 > ρmin = 0.00337
As max = ρmax b d OK!
= 0.02059 x 250 x 242
As max = 1,245.883 mm2

Mu cap = φ As max Fy (d - a/2) Check assumption that fs = Fy: Єy = Fy / Es = 0.00208


from the Strain Diagram,
a= As max Fy Єs = 0.003 (d - c) / c
0.85 fc' b a = As Fy / 0.85 fc' b
a= 88.16 mm a = 86.603 mm
c = a / β1
Mu cap = 92.100 kN-m c = 101.886 mm

NOTE: Mu cap > Mu Єs = 0.00413 > Єy = 0.00208 OK! Assumption is correct!

Analyze beam as SRB!


solving fs' using QUADRATIC EQN: fs' = 103.14 MPa
REINFORCEMENT:
TENSION: using 16 - mm φ rebars
As = 1,223.915
Ab = 201.062
N= 6.09 say 7 pc/s.

Therefore: USE 7 - 16-mm 𝛟 rebars.


ld 12 F y α β λ
DEVELOPMENT LENGTH: db
= Requirements:
20 fc'
a. Clear spacing of bars being developed > [db = 16 mm] OK!
Reinforcement Location Factor, α 1.3 clear spacing = 250 - 2(50 + 10 + 16) = 98 mm
Coating Factor, β 1.0 b. Clear cover = 50 mm > [db = 16 mm] OK!
Lightweight Aggregate Factor, λ 1.0 αβ = 1.3 < 1.7 c. STIRRUPS according to ACI Code.
Diameter of the rebar, db 16 OK!
As REQD / As PROV 0.87 ld = 12 (415) (1.3) (1.0) (1.0) (0.87) (16)
20 √27.6
ld = 857.30 mm > 300 mm OK!
SHEAR
Half of SHEAR DIAGRAM:
Vu = 61.649 kN Vu 61.649
Vud = 55.681 kN Vud 55.681

φ Vc = 39.730 kN φ Vc 39.730

0.5 φ Vc = 19.865 kN
0.5 φ Vc 19.865

A B C D E

Vu > φ Vc 0.242 2.258

Provide STIRRUPS! 0.889 1.611

1.694 0.806

DESIGN OF STIRRUPS
From B - C: Design stirrups. using 10 - mm φ STIRRUPS:
From C - D: Provide minimum stirrups. Ab = 78.540 sq.mm
From D - E: No stirrups required. Av = 2 Ab = 157.080 sq.mm

Maximum Spacing, Smax: Vu = Vud


Vs = (Vu - φ Vc)/ φ ⅔ [√fc’] bw d = 211.894 kN
Vs = 21.268 kN ⅓ [√fc’] bw d = 105.947 kN

Vs = 21.268 kN < ⅔ [√fc’] bw d = 211.894 kN OK!

Since: Vs = 21.268 kN < ⅓ [√fc’] bw d = 105.947 kN

Smax, smallest of: a. d/2 = 121 mm Smax = 121.000 mm


b. 600 mm
c. 3 Av Fy/bw = 782.257 mm

@ x = 0.242 m (from support face): Vux = 55.681 kN

S= φ Av Fy d = 741.749 mm (S > Smax) not OK!


Vux - φ Vc use S = Smax = 121.000 mm

NOTE: Assume that only two spacings are required between distance B to C.

@ x = 0.242 + (0.889 - 0.242)/2 = 0.566 m (from support face): Vux = Vud

S= φ Av Fy d = 741.749 mm (S > Smax) not OK!


Vux - φ Vc use S = Smax = 121.000 mm

SKETCH

A B C D E

2 @ 121 mm No STIRRUPS required!


1 @ 50 mm 3 @ 121 mm 3 @ 121 mm 7 @ 121 mm

1
DESIGN OF BEAM (ROOF BEAM) For SINGLY REINFORCED BEAMS:
Assume fs = Fy:
(15m BEAMS)
Mu = φ R b d^2 = 25.215 kN-m
GIVEN: solve for R:
b 250 mm Mu 25.215 kN-m R = Mu / φ b d^2 = 25.215 (10^6) / 0.9 (250) (242^2)
h 300 mm 𝛟 0.90 R = 1.914
clear cover 40 mm β1 0.85 ρ = 0.85 (fc'/Fy) [1 - √(1 - 2R/0.85 fc')]
d 242 mm Vu 9.721 kN ρ = 0.00482
d' 58 mm 𝛟 0.75
Fy 415 Mpa Tension Bars 16 - mm φ As = ρ b d
fc' 27.6 Mpa Comp. Bars 16 - mm φ As = 291.610 sq.mm.
L 15000 mm Stirrups 10 - mm φ

DUCTILITY:
STEEL RATIO: ρb 0.02840 Maximum/Minimum Steel Ratio:
ρmax 0.02059 ρ = 0.00482 < ρmax = 0.02059
ρmin 0.00337 OK! (Ductile)

check if SRB or DRB:


ρ = 0.00482 > ρmin = 0.00337
As max = ρmax b d OK!
= 0.02059 x 250 x 242
As max = 1,245.883 mm2

Mu cap = φ As max Fy (d - a/2) Check assumption that fs = Fy: Єy = Fy / Es = 0.00208


from the Strain Diagram,
a= As max Fy Єs = 0.003 (d - c) / c
0.85 fc' b a = As Fy / 0.85 fc' b
a= 88.16 mm a = 20.634 mm
c = a / β1
Mu cap = 92.100 kN-m c = 24.275 mm

NOTE: Mu cap > Mu Єs = 0.02691 > Єy = 0.00208 OK! Assumption is correct!

Analyze beam as SRB!


#NUM!
REINFORCEMENT:
TENSION: using 16 - mm φ rebars
As = 291.610
Ab = 201.062
N= 1.45 say 2 pc/s.

Therefore: USE 2 - 16-mm 𝛟 rebars.


ld 12 F y α β λ
DEVELOPMENT LENGTH: db
= Requirements:
20 fc'
a. Clear spacing of bars being developed > [db = 16 mm] OK!
Reinforcement Location Factor, α 1.3 clear spacing = 250 - 2(50 + 10 + 16) = 98 mm
Coating Factor, β 1.0 b. Clear cover = 50 mm > [db = 16 mm] OK!
Lightweight Aggregate Factor, λ 1.0 αβ = 1.3 < 1.7 c. STIRRUPS according to ACI Code.
Diameter of the rebar, db 16 OK!
As REQD / As PROV 0.73 ld = 12 (415) (1.3) (1.0) (1.0) (0.73) (16)
20 √27.6
ld = 714.91 mm > 300 mm OK!
SHEAR
Half of SHEAR DIAGRAM:
Vu = 9.721 kN Vu 9.721
Vud = 9.407 kN Vud 9.407

φ Vc = 39.730 kN φ Vc 39.730

0.5 φ Vc = 19.865 kN
0.5 φ Vc 19.865

A B C D E

Vu < φ Vc 0.242 7.258

No STIRRUPS required! -23.153 30.653

-7.827 15.327

DESIGN OF STIRRUPS
From B - C: Design stirrups. using 10 - mm φ STIRRUPS:
From C - D: Provide minimum stirrups. Ab = 78.540 sq.mm
From D - E: No stirrups required. Av = 2 Ab = 157.080 sq.mm

Maximum Spacing, Smax: Vu = Vud


Vs = (Vu - φ Vc)/ φ ⅔ [√fc’] bw d = 211.894 kN
Vs = -40.431 kN ⅓ [√fc’] bw d = 105.947 kN

Vs = -40.431 kN < ⅔ [√fc’] bw d = 211.894 kN OK!

Since: Vs = -40.431 kN < ⅓ [√fc’] bw d = 105.947 kN

Smax, smallest of: a. d/2 = 121 mm Smax = 121.000 mm


b. 600 mm
c. 3 Av Fy/bw = 782.257 mm

@ x = 0.242 m (from support face): Vux = 9.407 kN

S= φ Av Fy d (S < Smax) OK!


Vux - φ Vc

NOTE: Assume that only two spacings are required between distance B to C.

@ x = 0.242 + (-23.153 - 0.242)/2 = -11.456 m (from support face): Vux = 24.569 kN

S= φ Av Fy d (S < Smax) OK!


Vux - φ Vc

SKETCH

A B C D E

No STIRRUPS required!

1
TWO-WAY SLAB DESIGN (Analysis by The Coefficient Method)

Slab Case # 1 Analysis:


bbeam (m) 0.250
hbeam (m) 0.300 m = La (clear span) / Lb (clear span) = = 2.15 / 2.25
La (shorter span) (m) 2.40 m = 0.96
Lb (longer span) (m) 2.50
tslab (m) 0.150 m = 0.96 > 0.5 (Analyze as TWO-WAY SLAB)
REBARS (mmφ) 12
fc' (Mpa) 27.6 for m = 0.96:
Fy (Mpa) 415 Ca neg = 0.000 Ca ,DL = 0.039 Ca,LL = 0.039
ωU LL (kPa) 3.80 Cb neg = 0.000 Cb,DL = 0.034 Cb,LL = 0.034 Ra = (1-W
ωU DL (kPa) 3.88

LOAD: General Formulas:


2 2
ωU LL = 1.6 (3.80) = 6.08 kPa Ma neg = Ca neg ωU TOT La Ma pos,DL = Ca DL ωU DL La
ωU DL = 1.2 (3.88) = 4.66 kPa Ma pos,LL = Ca LL ωU LL La2
ωU TOT = 10.74 kPa

MIDDLE STRIP MOMENTS: Steel Ratio:


a. NEGATIVE MOMENT AT CONTINUOUS EDGE ρb 0.02840
Ma neg = 0.000 (10.74) (2.15)^2 = 0.00 kN-m ρmax 0.02130
Mb neg = 0.000 (10.74) (2.25)^2 = 0.00 kN-m ρmin 0.00180

b. POSITIVE MOMENT Maximum Spacing, Smax:


Ma pos,DL = 0.039 (4.66) (2.15)^2 = 0.84 kN-m Smax = 2 x slab thickess = 2 (0.15)
Ma pos,LL = 0.039 (6.08) (2.25)^2 = 1.10 kN-m Smax = 300 mm
Ma pos,TOT = 1.94 kN-m
Lb (longer span)
Mb pos,DL = 0.034 (4.66) (2.25)^2 = 0.80 kN-m
Mb pos,LL = 0.034 (6.08) (2.25)^2 = 1.05 kN-m
Mb pos,TOT = 1.85 kN-m

c. NEGATIVE MOMENT AT DISCONTINUOUS EDGE La (shorter span)


Ma neg = (1/3) (1.94 kN-m) = 0.65 kN-m
Mb neg = (1/3) (1.85 kN-m) = 0.62 kN-m

REINFORCEMENT: using 12-mm φ bars


a. SHORT DIRECTION: (where d = 124 mm) b. LONG DIRECTION: (where dmid = 112 mm and dsup = 124 mm)
MIDSPAN: MU = 1.94 kN-m MIDSPAN: MU = 1.85 kN-m
ρ = 0.00034 [ρ < ρmin] use ρ = ρmin ρ = 0.00040 [ρ < ρmin] use ρ = ρmin
As = 270.00 sq.mm. As = 270.00 sq.mm.
S = 418.89 mm [S > Smax] not OK! S = 418.89 mm [S > Smax] not OK!
use S = 300 mm use S = 300 mm

CONTINUOUS: MU = 0.00 kN-m CONTINUOUS: MU = 0.00 kN-m


ρ= 0.0018 [ρ < ρmin] use ρ = ρmin ρ= 0.0018 [ρ < ρmin] use ρ = ρmin
As = 270.00 sq.mm. As = 270.00 sq.mm.
S = 418.89 mm [S > Smax] not OK! S = 418.89 mm [S > Smax] not OK!
use S = 300 mm use S = 300 mm

DISCONTINUOUS: MU = 0.65 kN-m DISCONTINUOUS: MU = 0.62 kN-m


ρ = 0.00011 [ρ < ρmin] use ρ = ρmin ρ = 0.00011 [ρ < ρmin] use ρ = ρmin
As = 270.00 sq.mm. As = 270.00 sq.mm.
S = 418.89 mm [S > Smax] not OK! S = 418.89 mm [S > Smax] not OK!
use S = 300 mm use S = 300 mm
SHEAR:
WTOT LOAD = ωU TOT (La) (Lb) 2.15 m
= 10.74 (2.15) (2.25)
WTOT LOAD = 51.95 kN

Load/m on the long beam, Rb:


Rb = (1-Wb)(WTOT LOAD) / 2 (Lb) where Wb = 0.46
1.00 m
= 0.54 (51.95) / 2 (2.25)

2.25 m
Rb = 6.23 kN

Load/m on the short beam, Ra:


Ra = (1-Wa)(WTOT LOAD) / 2 (La) where Wb = 0.54
= 0.46 (51.95) / 2 (2.15)
Ra = 5.56 kN

Shear strength of the slab, φ Vc:


φ Vc = φ (1/6) √fc' b d
= 0.85 (1/6) √(27.6) (1000) (124)
φ Vc = 92.29 kN

NOTE: Rb,d < φ Vc


OK!

BAR DETAILING

BOTTOM BARS: Use 12-mm φ bars TOP BARS: Use 12-mm φ bars
150 250

150 250
S = 300

S = 300
2.25 m

2.25 m
S = 300

S = 300
S = 300

S = 300

150 250
S = 300 S = 300 S = 300 S = 300 S = 300 S = 300
150 250
2.15 m 2.15 m

NOTE: All end of BOTTOM BARS should be NOTE: All end of TOP BARS should be
terminated w/out hooks. standard 90° hook.

BOTTOM BARS TOP BARS


TWO-WAY SLAB DESIGN (Analysis by The Coefficient Method)

Slab Case # 1 Analysis:


bbeam (m) 0.250
hbeam (m) 0.300 m = La (clear span) / Lb (clear span) = = 2.25 / 2.35
La (shorter span) (m) 2.50 m = 0.96
Lb (longer span) (m) 2.60
tslab (m) 0.150 m = 0.96 > 0.5 (Analyze as TWO-WAY SLAB)
REBARS (mmφ) 12
fc' (Mpa) 27.6 for m = 0.96:
Fy (Mpa) 415 Ca neg = 0.000 Ca ,DL = 0.039 Ca,LL = 0.039
ωU LL (kPa) 7.20 Cb neg = 0.000 Cb,DL = 0.034 Cb,LL = 0.034 Ra = (1-W
ωU DL (kPa) 3.88

LOAD: General Formulas:


2 2
ωU LL = 1.6 (7.20) = 11.52 kPa Ma neg = Ca neg ωU TOT La Ma pos,DL = Ca DL ωU DL La
ωU DL = 1.2 (3.88) = 4.66 kPa Ma pos,LL = Ca LL ωU LL La2
ωU TOT = 16.18 kPa

MIDDLE STRIP MOMENTS: Steel Ratio:


a. NEGATIVE MOMENT AT CONTINUOUS EDGE ρb 0.02840
Ma neg = 0.000 (16.18) (2.25)^2 = 0.00 kN-m ρmax 0.02130
Mb neg = 0.000 (16.18) (2.35)^2 = 0.00 kN-m ρmin 0.00180

b. POSITIVE MOMENT Maximum Spacing, Smax:


Ma pos,DL = 0.039 (4.66) (2.25)^2 = 0.92 kN-m Smax = 2 x slab thickess = 2 (0.15)
Ma pos,LL = 0.039 (11.52) (2.35)^2 = 2.27 kN-m Smax = 300 mm
Ma pos,TOT = 3.19 kN-m
Lb (longer span)
Mb pos,DL = 0.034 (4.66) (2.35)^2 = 0.87 kN-m
Mb pos,LL = 0.034 (11.52) (2.35)^2 = 2.16 kN-m
Mb pos,TOT = 3.03 kN-m

c. NEGATIVE MOMENT AT DISCONTINUOUS EDGE La (shorter span)


Ma neg = (1/3) (3.19 kN-m) = 1.06 kN-m
Mb neg = (1/3) (3.03 kN-m) = 1.01 kN-m

REINFORCEMENT: using 12-mm φ bars


a. SHORT DIRECTION: (where d = 124 mm) b. LONG DIRECTION: (where dmid = 112 mm and dsup = 124 mm)
MIDSPAN: MU = 3.19 kN-m MIDSPAN: MU = 3.03 kN-m
ρ = 0.00056 [ρ < ρmin] use ρ = ρmin ρ = 0.00065 [ρ < ρmin] use ρ = ρmin
As = 270.00 sq.mm. As = 270.00 sq.mm.
S = 418.89 mm [S > Smax] not OK! S = 418.89 mm [S > Smax] not OK!
use S = 300 mm use S = 300 mm

CONTINUOUS: MU = 0.00 kN-m CONTINUOUS: MU = 0.00 kN-m


ρ= 0.0018 [ρ < ρmin] use ρ = ρmin ρ= 0.0018 [ρ < ρmin] use ρ = ρmin
As = 270.00 sq.mm. As = 270.00 sq.mm.
S = 418.89 mm [S > Smax] not OK! S = 418.89 mm [S > Smax] not OK!
use S = 300 mm use S = 300 mm

DISCONTINUOUS: MU = 1.06 kN-m DISCONTINUOUS: MU = 1.01 kN-m


ρ = 0.00019 [ρ < ρmin] use ρ = ρmin ρ = 0.00018 [ρ < ρmin] use ρ = ρmin
As = 270.00 sq.mm. As = 270.00 sq.mm.
S = 418.89 mm [S > Smax] not OK! S = 418.89 mm [S > Smax] not OK!
use S = 300 mm use S = 300 mm
SHEAR:
WTOT LOAD = ωU TOT (La) (Lb) 2.25 m
= 16.18 (2.25) (2.35)
WTOT LOAD = 85.55 kN

Load/m on the long beam, Rb:


Rb = (1-Wb)(WTOT LOAD) / 2 (Lb) where Wb = 0.46
1.00 m
= 0.54 (85.55) / 2 (2.35)

2.35 m
Rb = 9.83 kN

Load/m on the short beam, Ra:


Ra = (1-Wa)(WTOT LOAD) / 2 (La) where Wb = 0.54
= 0.46 (85.55) / 2 (2.25)
Ra = 8.75 kN

Shear strength of the slab, φ Vc:


φ Vc = φ (1/6) √fc' b d
= 0.85 (1/6) √(27.6) (1000) (124)
φ Vc = 92.29 kN

NOTE: Rb,d < φ Vc


OK!

BAR DETAILING

BOTTOM BARS: Use 12-mm φ bars TOP BARS: Use 12-mm φ bars
150 250

150 250
S = 300

S = 300
2.35 m

2.35 m
S = 300

S = 300
S = 300

S = 300

150 250
S = 300 S = 300 S = 300 S = 300 S = 300 S = 300
150 250
2.25 m 2.25 m

NOTE: All end of BOTTOM BARS should be NOTE: All end of TOP BARS should be
terminated w/out hooks. standard 90° hook.

BOTTOM BARS TOP BARS


ONE-WAY SLAB DESIGN (Analysis by The Coefficient Method)

bbeam (m) 0.250


hbeam (m) 0.300
L (m) 5.00
tslab (m) 0.150 165.48 > 150 not OK!
REBARS (mmφ) 12
fc' (Mpa) 27.8
Fy (Mpa) 276 Mu 46.36
ωU LL (kPa) 4.80 b 1000.00
ωU DL (kPa) 15.24 d 124
Ru 3.350149893
LOAD: p 0.013147752
ωU LL = 1.6 (4.80) = 7.68 kPa Use p 0.005072464
ωU DL =1.2 (15.24) = 18.282 kPa As 628.9855072
ωU TOT = 25.962 kPa N 5.56
Analyzing 1 m strip S 179.81
ωU = 25.962 kN/m Use S 220

Mu = 46.36071 kN-m use 12 mm main bars spaced at 220 o.c.

Temp Bars 0.002bh


300 mm^2
Spacing 261.8

use 10 mm temp. bars spaced at 260 o.c.


Design of Square Base Plate on Full Area of Concrete

COMPUTATION
Steel Member : L4x4x3/4

* Allowable Bearing Stress on Concrete


Data Needed :
P= 86.81 KN Fp = 0.35 f'c = 0.35(21)
bf = 28.58 mm Fp = 7.35 MPa
d= 101.60 mm
f'c = 21.00 MPa * Allowable Bending Stress on Steel
Fy = 248.00 MPa
Fb = 0.75 Fy = 0.75(248)
Fb = 186.00 MPa
Solve for m = ( N - 0.95d ) / 2 𝑃
m = ( 109 - 96.52 ) / 2 * Area of Base Plate , 𝐴=
𝐹𝑝
m = 6.24 mm
A= 86.812 * 1000 N
Solve for n = ( N - 0.8b ) / 2 7.35 N/mm²
n = ( 109 - 22.86 ) / 2 A= 11811.16 mm²
n = 43.07 mm
* Width of the Base Plate , 𝑁= 𝐴
𝑃
* Actual Bearing Pressure , 𝑓𝑝 = N =
𝐴𝑎𝑐𝑡𝑢𝑎𝑙 11811.16 mm²

fp = 86.812 * 1000 N N = 108.68 mm say 109.00 mm


109 * 109 mm² use 218.00 mm
fp = 7.3068 MPa use 218.00 mm

b = 28.58 mm
m

3 𝑓𝑝 𝑥2
* Plate Thickness , 𝑡=
𝐹𝑏
0.95d = 96.52 mm

use 218.00 mm
d = 101.60 mm

3 * 7.3068 * 43.07²
t=
186.00
t= 14.7857 mm
say 20.00 mm
n
m

0.8b = 22.86 mm

Therefore, use
use 218.00 mm mm x use 218.00 mm mm x 20 mm
BASE PLATE
t = 20.00 mm
PAGE NO. 1

****************************************************
* *
* STAAD.Pro V8i SELECTseries6 *
* Version 20.07.11.33 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= OCT 22, 2019 *
* Time= 22:57:31 *
* *
* USER ID: *
****************************************************

1. STAAD PLANE
INPUT FILE: C:\Users\ACER\Documents\SCHOOL FILES\5TH YEAR FIRST SEM\THESIS\ELEVATED MULTI-PURPOSE BLDG.. .STD
2. START JOB INFORMATION
3. ENGINEER DATE 03-OCT-19
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 3 1.003 0 0; 4 3.603 0 0; 5 6.003 0 0; 6 8.603 0 0; 7 11.003 0 0; 8 13.603 0 0
9. 9 0 0 0; 10 14.606 0 0
10. MEMBER INCIDENCES
11. 2 3 4; 3 4 5; 4 5 6; 5 6 7; 6 7 8; 7 3 9; 8 8 10
12. DEFINE MATERIAL START
13. ISOTROPIC STEEL
14. E 2.05E+008
15. POISSON 0.3
16. DENSITY 76.8195
17. ALPHA 1.2E-005
18. DAMP 0.03
19. TYPE STEEL
20. STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2
21. END DEFINE MATERIAL
22. MEMBER PROPERTY AMERICAN
23. 2 TO 8 TABLE ST C3X6
24. CONSTANTS
25. MATERIAL STEEL ALL
26. SUPPORTS
27. 3 TO 10 PINNED
28. LOAD 1 LOADTYPE DEAD TITLE DL
29. MEMBER LOAD
30. 2 TO 8 UNI GY -0.0756
31. SELFWEIGHT Y -1 LIST ALL
32. LOAD 2 LOADTYPE LIVE TITLE LL
33. MEMBER LOAD
34. 2 TO 8 UNI GY -0.3906
35. LOAD 3 LOADTYPE WIND TITLE WL 1
36. MEMBER LOAD
37. 2 TO 6 UNI GY -0.712
38. LOAD 4 LOADTYPE WIND TITLE WL 2
STAAD PLANE -- PAGE NO. 2

39. MEMBER LOAD


40. 2 TO 6 UNI GY 1.177
41. 7 8 UNI GY 1.979
42. LOAD COMB 5 1.2 DL + 0.5 LL + 1.2 WL 1
43. 1 1.2 2 0.5 3 1.2
44. LOAD COMB 6 1.2 DL + 0.5 LL + 1.2 WL 2
45. 1 1.2 2 0.5 4 1.2
46. LOAD COMB 7 0.9 DL + 1.0 WL 1
47. 1 0.9 3 1.0
48. LOAD COMB 8 0.9 DL + 1.0 WL 2
49. 1 0.9 4 1.0
50. LOAD COMB 9 1.0 DL + 1.0 LL
51. 1 1.0 2 1.0
52. PERFORM ANALYSIS

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 8 NUMBER OF MEMBERS 7


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 8

SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER

ORIGINAL/FINAL BAND-WIDTH= 6/ 6/ 7 DOF


TOTAL PRIMARY LOAD CASES = 4, TOTAL DEGREES OF FREEDOM = 8
TOTAL LOAD COMBINATION CASES = 5 SO FAR.
SIZE OF STIFFNESS MATRIX = 1 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.0/1466574.5 MB

53. LOAD LIST 1 TO 4 9


54. PARAMETER 1
55. CODE AISC UNIFIED 2010
56. FYLD 248000 MEMB 2 TO 6
57. METHOD LRFD
58. CHECK CODE MEMB 2 TO 6
STAAD PLANE -- PAGE NO. 3

STAAD.PRO CODE CHECKING - (AISC-360-10-LRFD) v1.4a


********************************************

ALL UNITS ARE - KN METE (UNLESS OTHERWISE Noted)

MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/


FX MY MZ LOCATION
=======================================================================

2 ST C3X6 (AISC SECTIONS)


PASS Eq. H1-1b 0.120 4
0.00 T 0.00 -0.63 2.60

3 ST C3X6 (AISC SECTIONS)


PASS Eq. H1-1b 0.118 4
0.00 T 0.00 -0.63 0.00

4 ST C3X6 (AISC SECTIONS)


PASS Eq. H1-1b 0.117 4
0.00 T 0.00 -0.61 0.00

5 ST C3X6 (AISC SECTIONS)


PASS Eq. H1-1b 0.118 4
0.00 T 0.00 -0.63 2.40

6 ST C3X6 (AISC SECTIONS)


PASS Eq. H1-1b 0.120 4
0.00 T 0.00 -0.63 0.00

59. PARAMETER 2
60. CODE AISC UNIFIED 2010
61. STEEL MEMBER TAKE OFF LIST 2 TO 6
STAAD PLANE -- PAGE NO. 4

STEEL TAKE-OFF
--------------

PROFILE LENGTH(METE) WEIGHT(KN )

ST C3X6 12.60 1.099


----------------
TOTAL = 1.099

MEMBER PROFILE LENGTH WEIGHT


(METE) (KN )

2 ST C3X6 2.60 0.227


3 ST C3X6 2.40 0.209
4 ST C3X6 2.60 0.227
5 ST C3X6 2.40 0.209
6 ST C3X6 2.60 0.227
----------------
TOTAL = 1.099

************ END OF DATA FROM INTERNAL STORAGE ************

62. FINISH

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= OCT 22,2019 TIME= 22:57:32 ****


STAAD PLANE -- PAGE NO. 5

************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2015 Bentley Systems, Inc.
* http://www.bentley.com *
************************************************************
PAGE NO. 1

****************************************************
* *
* STAAD.Pro V8i SELECTseries6 *
* Version 20.07.11.33 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= OCT 22, 2019 *
* Time= 23: 1:50 *
* *
* USER ID: *
****************************************************

1. STAAD PLANE
INPUT FILE: C:\Users\ACER\Documents\SCHOOL FILES\5TH YEAR FIRST SEM\THESIS\ELEVATED MULTI-PURPOSE BLDG.. .STD
2. START JOB INFORMATION
3. ENGINEER DATE 04-OCT-19
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 2 17.006 0 0; 20 2.203 0.388 0; 21 14.803 0.388 0; 22 1.153 0.203 0
9. 23 15.853 0.203 0; 24 3.253 0.574 0; 25 13.753 0.574 0; 26 4.303 0.759 0
10. 27 12.703 0.759 0; 28 5.353 0.944 0; 29 11.653 0.944 0; 30 6.403 1.129 0
11. 31 10.603 1.129 0; 32 7.453 1.314 0; 33 9.553 1.314 0; 34 8.503 1.5 0
12. 35 0 1.015 0; 36 17.006 1.015 0; 37 2.203 1.403 0; 38 14.803 1.403 0
13. 39 1.153 1.218 0; 40 15.853 1.218 0; 41 3.253 1.589 0; 42 13.753 1.589 0
14. 43 4.303 1.774 0; 44 12.703 1.774 0; 45 5.353 1.959 0; 46 11.653 1.959 0
15. 47 6.403 2.144 0; 48 10.603 2.144 0; 49 7.453 2.329 0; 50 9.553 2.329 0
16. 51 8.503 2.515 0
17. MEMBER INCIDENCES
18. 17 1 35; 18 2 36; 19 20 37; 20 21 38; 21 22 39; 22 23 40; 23 24 41; 24 25 42
19. 25 26 43; 26 27 44; 27 28 45; 28 29 46; 29 30 47; 30 31 48; 31 32 49; 32 33 50
20. 33 34 51; 35 22 20; 36 20 24; 37 24 26; 38 26 28; 39 28 30; 40 30 32; 41 32 34
21. 42 34 33; 43 33 31; 44 31 29; 45 29 27; 46 27 25; 47 25 21; 48 21 23; 66 1 39
22. 67 22 37; 68 20 41; 69 24 43; 70 26 45; 71 28 47; 72 30 49; 73 32 51; 74 51 33
23. 75 50 31; 76 48 29; 77 46 27; 78 44 25; 79 42 21; 80 38 23; 81 40 2; 131 35 39
24. 132 39 37; 133 37 41; 134 41 43; 135 43 45; 136 45 47; 137 47 49; 138 49 51
25. 139 51 50; 140 50 48; 141 48 46; 142 46 44; 143 44 42; 144 42 38; 145 38 40
26. 146 40 36; 147 1 22; 148 23 2
27. START GROUP DEFINITION
28. JOINT
29. _JOINTS 1 2 20 TO 51
30. MEMBER
31. _TOPCHORD 131 TO 146
32. _BOTTOMCHORD 35 TO 48 147 148
33. _WEB 17 TO 33 66 TO 81
34. END GROUP DEFINITION
35. DEFINE MATERIAL START
36. ISOTROPIC STEEL
37. E 2.05E+008
38. POISSON 0.3
STAAD PLANE -- PAGE NO. 2

39. DENSITY 76.8195


40. ALPHA 1.2E-005
41. DAMP 0.03
42. TYPE STEEL
43. STRENGTH FY 253200 FU 407800 RY 1.5 RT 1.2
44. END DEFINE MATERIAL
45. MEMBER PROPERTY AMERICAN
46. 17 TO 33 66 TO 81 TABLE ST L404010
47. 35 TO 48 131 TO 148 TABLE ST L404012
48. CONSTANTS
49. MATERIAL STEEL ALL
50. SUPPORTS
51. 22 23 PINNED
52. LOAD 1 LOADTYPE DEAD TITLE DL
53. SELFWEIGHT Y -1
54. MEMBER LOAD
55. 131 TO 146 UNI GY -3.192
56. LOAD 2 LOADTYPE LIVE TITLE LL
57. MEMBER LOAD
58. 17 TO 33 35 TO 48 66 TO 81 131 TO 148 UNI GY -1.
59. LOAD 3 LOADTYPE WIND TITLE WL 1
60. MEMBER LOAD
61. 131 TO 146 UNI GY -2.21
62. LOAD 4 LOADTYPE WIND TITLE WL 2
63. MEMBER LOAD
64. 132 TO 145 UNI GY 4.472
65. 131 146 UNI GY 6.344
66. LOAD COMB 5 1.2 DL + 0.5 LL +1.2 WL 1
67. 1 1.2 2 0.5 3 1.2
68. LOAD COMB 6 1.2 DL + 0.5 LL +1.2 WL 2
69. 1 1.2 2 0.5 4 1.2
70. LOAD COMB 7 0.9 DL + 1.0 WL 1
71. 1 0.9 3 1.0
72. LOAD COMB 8 0.9 DL + 1.0 WL 2
73. 1 0.9 4 1.0
74. LOAD COMB 9 1.0 DL + 1.0 LL
75. 1 1.0 2 1.0
76. PERFORM ANALYSIS

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 34 NUMBER OF MEMBERS 65


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 2

SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER

ORIGINAL/FINAL BAND-WIDTH= 21/ 3/ 12 DOF


TOTAL PRIMARY LOAD CASES = 4, TOTAL DEGREES OF FREEDOM = 98
STAAD PLANE -- PAGE NO. 3

TOTAL LOAD COMBINATION CASES = 5 SO FAR.


SIZE OF STIFFNESS MATRIX = 2 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 12.1/1466550.6 MB

77. LOAD LIST 1 TO 4 9


78. PARAMETER 1
79. CODE AISC UNIFIED 2010
80. FYLD 248000 MEMB 17 TO 33 35 TO 48 66 TO 81 131 TO 146
81. METHOD LRFD
82. CHECK CODE ALL
STAAD PLANE -- PAGE NO. 4

STAAD.PRO CODE CHECKING - (AISC-360-10-LRFD) v1.4a


********************************************

ALL UNITS ARE - KN METE (UNLESS OTHERWISE Noted)

MEMBER TABLE RESULT/ CRITICAL COND/ RATIO/ LOADING/


FX MY MZ LOCATION
=======================================================================

17 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.048 4
3.36 T 0.00 -0.34 1.01

18 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.048 4
3.36 T 0.00 0.34 1.01

19 ST L404010 (AISC SECTIONS)


PASS Eq. Sec. D2 0.050 9
33.27 T 0.00 0.14 1.02

20 ST L404010 (AISC SECTIONS)


PASS Eq. Sec. D2 0.050 9
33.27 T 0.00 -0.14 1.02

21 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.029 9
13.06 C 0.00 -0.07 0.00

22 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.029 9
13.06 C 0.00 0.07 0.00
STAAD PLANE -- PAGE NO. 5

23 ST L404010 (AISC SECTIONS)


PASS Eq. Sec. D2 0.037 9
24.23 T 0.00 0.07 1.02

24 ST L404010 (AISC SECTIONS)


PASS Eq. Sec. D2 0.037 9
24.23 T 0.00 -0.07 1.02

25 ST L404010 (AISC SECTIONS)


PASS Eq. Sec. D2 0.023 9
15.14 T 0.00 0.00 1.02

26 ST L404010 (AISC SECTIONS)


PASS Eq. Sec. D2 0.023 9
15.14 T 0.00 -0.00 1.02

27 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.014 9
6.02 T 0.00 -0.07 1.01

28 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.014 9
6.02 T 0.00 0.07 1.01

29 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.021 9
3.13 C 0.00 -0.13 1.01
STAAD PLANE -- PAGE NO. 6

30 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.021 9
3.13 C 0.00 0.13 1.01

31 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.047 9
12.05 C 0.00 -0.25 1.02

32 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.047 9
12.05 C 0.00 0.25 1.02

33 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.026 9
11.65 C 0.00 0.00 0.00

35 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.162 9
85.05 C 0.00 0.27 0.00

36 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.101 9
53.26 C 0.00 0.13 0.00

37 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.059 9
31.15 C 0.00 0.08 0.00
STAAD PLANE -- PAGE NO. 7

38 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.036 9
18.81 C 0.00 0.03 0.00

39 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.035 9
15.98 C 0.00 0.17 1.07

40 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.045 9
23.49 C 0.00 -0.06 0.00

41 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.081 9
39.80 C 0.00 0.38 1.07

42 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.081 9
39.80 C 0.00 0.38 0.00

43 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.045 9
23.49 C 0.00 -0.06 1.07

44 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.035 9
15.98 C 0.00 0.17 0.00
STAAD PLANE -- PAGE NO. 8

45 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.036 9
18.81 C 0.00 0.03 1.07

46 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.059 9
31.15 C 0.00 0.08 1.07

47 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.101 9
53.26 C 0.00 0.13 1.07

48 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.162 9
85.05 C 0.00 0.27 1.07

66 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.031 9
9.00 T 0.00 0.18 1.68

67 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.159 9
61.96 C 0.00 0.16 0.00

68 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.122 9
47.71 C 0.00 0.10 0.00
STAAD PLANE -- PAGE NO. 9

69 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.086 9
33.45 C 0.00 0.11 0.00

70 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.049 9
19.08 C 0.00 0.11 0.00

71 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.024 9
3.24 C 0.00 0.15 1.59

72 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.026 9
9.81 T 0.00 0.14 0.00

73 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.053 9
24.97 T 0.00 0.26 1.60

74 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.053 9
24.97 T 0.00 0.26 0.00

75 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.026 9
9.81 T 0.00 0.14 1.59
STAAD PLANE -- PAGE NO. 10

76 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.024 9
3.24 C 0.00 0.15 0.00

77 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.049 9
19.08 C 0.00 0.11 1.59

78 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.086 9
33.45 C 0.00 0.11 1.59

79 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.122 9
47.71 C 0.00 0.10 1.60

80 ST L404010 (AISC SECTIONS)


PASS Sec. E1 0.159 9
61.96 C 0.00 0.16 1.59

81 ST L404010 (AISC SECTIONS)


PASS Eq. H1-1b 0.031 9
9.00 T 0.00 0.18 0.00

131 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.095 4
0.29 C 0.00 -0.83 1.17
STAAD PLANE -- PAGE NO. 11

132 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.089 9
4.82 T 0.00 0.75 0.00

133 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.102 9
36.45 C 0.00 0.59 0.00

134 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.130 9
68.04 C 0.00 0.51 0.00

135 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.171 9
89.98 C 0.00 0.45 0.00

136 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.195 9
102.15 C 0.00 0.39 0.00

137 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.199 9
104.59 C 0.00 0.36 0.00

138 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.185 9
97.02 C 0.00 0.24 0.00
STAAD PLANE -- PAGE NO. 12

139 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.185 9
97.02 C 0.00 0.24 1.07

140 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.199 9
104.59 C 0.00 0.36 1.07

141 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.195 9
102.15 C 0.00 0.39 1.07

142 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.171 9
89.98 C 0.00 0.45 1.07

143 ST L404012 (AISC SECTIONS)


PASS Sec. E1 0.130 9
68.04 C 0.00 0.51 1.07

144 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.102 9
36.45 C 0.00 0.59 1.07

145 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.089 9
4.82 T 0.00 0.75 1.07
STAAD PLANE -- PAGE NO. 13

146 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.095 4
0.29 C 0.00 -0.83 0.00

147 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.046 9
5.17 C 0.00 0.36 1.17

148 ST L404012 (AISC SECTIONS)


PASS Eq. H1-1b 0.046 9
5.17 C 0.00 0.36 0.00

83. FINISH

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= OCT 22,2019 TIME= 23: 1:51 ****


STAAD PLANE -- PAGE NO. 14

************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2015 Bentley Systems, Inc.
* http://www.bentley.com *
************************************************************
PAGE NO. 1

****************************************************
* *
* STAAD.Pro V8i SELECTseries6 *
* Version 20.07.11.33 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= OCT 22, 2019 *
* Time= 23: 4:21 *
* *
* USER ID: *
****************************************************

1. STAAD SPACE
INPUT FILE: C:\Users\ACER\Documents\SCHOOL FILES\5TH YEAR FIRST SEM\THESIS\ELEVATED MULTI-PURPOSE BLDG.. .STD
2. START JOB INFORMATION
3. ENGINEER DATE 05-OCT-19
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KN
7. JOINT COORDINATES
8. 1 0 0 0; 2 5 0 0; 3 10 0 0; 4 15 0 0; 5 20 0 0; 6 0 0 -5; 7 20 0 -5; 8 0 0 -10
9. 9 20 0 -10; 10 0 0 -15; 11 20 0 -15; 12 0 0 -20; 13 20 0 -20; 14 5 0 -20
10. 15 10 0 -20; 16 15 0 -20; 17 2.5 0 -5; 18 7.5 0 -5; 19 12.5 0 -5; 20 17.5 0 -5
11. 21 2.5 0 -7.5; 22 17.5 0 -7.5; 23 2.5 0 -12.5; 24 17.5 0 -12.5; 25 2.5 0 -17.5
12. 26 17.5 0 -17.5; 27 7.5 0 -17.5; 28 12.5 0 -17.5; 29 0 -3 0; 30 5 -3 0
13. 31 10 -3 0; 32 15 -3 0; 33 20 -3 0; 34 0 -3 -5; 35 20 -3 -5; 36 0 -3 -10
14. 37 20 -3 -10; 38 0 -3 -15; 39 20 -3 -15; 40 0 -3 -20; 41 20 -3 -20
15. 42 5 -3 -20; 43 10 -3 -20; 44 15 -3 -20; 45 2.5 -3 -5; 46 7.5 -3 -5
16. 47 12.5 -3 -5; 48 17.5 -3 -5; 49 2.5 -3 -7.5; 50 17.5 -3 -7.5; 51 2.5 -3 -12.5
17. 52 17.5 -3 -12.5; 53 2.5 -3 -17.5; 54 17.5 -3 -17.5; 55 7.5 -3 -17.5
18. 56 12.5 -3 -17.5; 57 0 4 0; 58 5 4 0; 59 10 4 0; 60 15 4 0; 61 20 4 0
19. 62 0 4 -5; 63 20 4 -5; 64 0 4 -10; 65 20 4 -10; 66 0 4 -15; 67 20 4 -15
20. 68 0 4 -20; 69 20 4 -20; 70 5 4 -20; 71 10 4 -20; 72 15 4 -20; 73 2.5 4 -5
21. 74 7.5 4 -5; 75 12.5 4 -5; 76 17.5 4 -5; 77 2.5 4 -7.5; 78 17.5 4 -7.5
22. 79 2.5 4 -12.5; 80 17.5 4 -12.5; 81 2.5 4 -17.5; 82 17.5 4 -17.5
23. 83 7.5 4 -17.5; 84 12.5 4 -17.5; 85 2.5 7 -5; 86 7.5 7 -5; 87 12.5 7 -5
24. 88 17.5 7 -5; 89 2.5 7 -7.5; 90 17.5 7 -7.5; 91 2.5 7 -12.5; 92 17.5 7 -12.5
25. 93 2.5 7 -17.5; 94 17.5 7 -17.5; 95 7.5 7 -17.5; 96 12.5 7 -17.5; 97 2.5 0 0
26. 98 17.5 0 0; 99 10 0 -5; 102 20 0 -17.5; 103 0 0 -17.5; 106 2.5 0 -20
27. 107 17.5 0 -20; 108 10 0 -17.5; 109 2.5 4 0; 110 17.5 4 0; 111 10 4 -5
28. 112 10 4 -17.5; 113 2.5 4 -20; 114 17.5 4 -20; 115 20 4 -17.5; 116 0 4 -17.5
29. 117 17.5 4 -10; 118 2.5 4 -10; 119 17.5 0 -10; 120 2.5 0 -10; 121 2.5 7 -10
30. 122 17.5 7 -10; 123 2.5 7 -15; 124 17.5 7 -15
31. MEMBER INCIDENCES
32. 1 1 97; 2 2 3; 3 3 4; 4 4 98; 5 1 6; 6 5 7; 7 6 8; 8 7 9; 11 10 103; 12 11 102
33. 13 12 106; 14 14 15; 15 15 16; 16 16 107; 17 6 17; 18 17 18; 19 18 99
34. 20 19 20; 21 20 7; 22 17 21; 23 20 22; 24 21 120; 25 22 119; 26 23 25
35. 27 24 26; 28 25 27; 29 27 108; 30 28 26; 31 1 29; 32 2 30; 33 3 31; 34 4 32
36. 35 5 33; 36 6 34; 37 7 35; 38 8 36; 39 9 37; 40 10 38; 41 11 39; 42 12 40
37. 43 13 41; 44 14 42; 45 15 43; 46 16 44; 47 17 45; 48 18 46; 49 19 47; 50 20 48
38. 51 21 49; 52 22 50; 53 23 51; 54 24 52; 55 25 53; 56 26 54; 57 27 55; 58 28 56
STAAD SPACE -- PAGE NO. 2

39. 59 1 57; 60 2 58; 61 3 59; 62 4 60; 63 5 61; 64 6 62; 65 7 63; 66 8 64


40. 67 9 65; 68 10 66; 69 11 67; 70 12 68; 71 13 69; 72 14 70; 73 15 71; 74 16 72
41. 75 17 73; 76 18 74; 77 19 75; 78 20 76; 79 21 77; 80 22 78; 81 23 79; 82 24 80
42. 83 25 81; 84 26 82; 85 27 83; 86 28 84; 87 68 113; 88 70 71; 89 71 72
43. 90 72 114; 91 69 115; 92 67 65; 93 65 63; 94 63 61; 95 61 110; 96 60 59
44. 97 59 58; 98 58 109; 99 57 62; 100 62 64; 101 64 66; 102 66 116; 103 81 83
45. 104 83 112; 105 84 82; 106 82 80; 107 80 117; 108 78 76; 109 76 75; 110 75 111
46. 111 74 73; 112 73 77; 113 77 118; 114 79 81; 115 73 85; 116 74 86; 117 75 87
47. 118 76 88; 119 77 89; 120 78 90; 121 79 91; 122 80 92; 123 81 93; 124 82 94
48. 125 83 95; 126 84 96; 127 93 95; 128 95 96; 129 96 94; 130 94 124; 131 92 122
49. 132 90 88; 133 88 87; 134 87 86; 135 86 85; 136 85 89; 137 89 121; 138 91 123
50. 139 97 2; 140 17 97; 141 98 5; 142 20 98; 143 99 19; 144 3 99; 147 102 13
51. 148 26 102; 149 103 12; 150 25 103; 155 28 19; 156 27 18; 157 106 14
52. 158 25 106; 159 107 13; 160 26 107; 161 108 28; 162 15 108; 163 62 73
53. 164 76 63; 165 109 57; 166 73 109; 167 110 60; 168 76 110; 169 111 74
54. 170 59 111; 171 112 84; 172 71 112; 173 113 70; 174 81 113; 175 114 69
55. 176 82 114; 177 115 67; 178 82 115; 179 116 68; 180 81 116; 181 117 78
56. 182 65 117; 183 118 79; 184 64 118; 185 83 74; 186 84 75; 187 10 8; 188 11 9
57. 189 119 24; 190 9 119; 191 120 23; 192 8 120; 193 95 86; 194 87 96; 195 121 91
58. 196 122 90; 197 123 93; 198 124 92
59. START GROUP DEFINITION
60. MEMBER
61. _BEAMS 1 TO 8 11 TO 30 87 TO 114 127 TO 144 147 TO 150 155 TO 192 195 TO 198
62. _COLUMNS 31 TO 86 115 TO 126
63. END GROUP DEFINITION
64. DEFINE MATERIAL START
65. ISOTROPIC CONCRETE
66. E 2.17185E+007
67. POISSON 0.17
68. DENSITY 23.5616
69. ALPHA 1E-005
70. DAMP 0.05
71. TYPE CONCRETE
72. STRENGTH FCU 27579
73. END DEFINE MATERIAL
74. MEMBER PROPERTY AMERICAN
75. 31 TO 86 115 TO 126 PRIS YD 0.5 ZD 0.5
76. 1 TO 8 11 TO 30 87 TO 114 127 TO 144 147 TO 150 155 TO 198 PRIS YD 0.3 ZD 0.25
77. CONSTANTS
78. MATERIAL CONCRETE ALL
79. SUPPORTS
80. 29 TO 56 PINNED
81. DEFINE WIND LOAD

*** NOTE: If any floor diaphragm is present in the model Wind Load definition
should be defined after Floor Diaphragm definition. Otherwise wind
load generation may be unsuccessful during analysis.

82. TYPE 1 WIND 1


83. <! STAAD PRO GENERATED DATA DO NOT MODIFY !!!
84. ASCE-7-2010:PARAMS 270.000 KMPH 0 1 1 0 0.000 FT 0.000 FT 0.000 FT 1 -
85. 1 12.000 M 20.000 M 20.000 M 2.000 0.010 0 -
86. 0 0 0 0 0.757 1.000 1.000 0.850 0 -
87. 0 0 0 0.849 0.800 -0.550
88. !> END GENERATED DATA BLOCK
STAAD SPACE -- PAGE NO. 3

WARNING- One or more lines are too long and will be split into 2 lines.
This may not work for all commands. Please check.
89. INT 2.3657 2.3657 2.40486 2.44103 2.4747 2.50625 2.53597 2.5641 2.59083 -
90. 2.61632 -
91. 2.64069 2.66406 2.68652 2.70815 2.72902 HEIG 0 4.572 5.14338 5.71477 -
92. 6.28615 6.85754 7.42892 8.00031 8.57169 9.14308 9.71446 10.2858 -
93. 10.8572 11.4286 12
94. EXP 0.99 JOINT 1 TO 99 102 103 106 TO 124
95. LOAD 1 LOADTYPE DEAD TITLE DL
96. MEMBER LOAD
97. 13 TO 16 87 TO 90 157 159 173 175 UNI GY -15.514
98. 28 TO 30 103 TO 105 148 150 161 171 178 180 UNI GY -18.674
99. 182 184 190 192 UNI GY -10.334
100. 17 TO 21 109 TO 111 143 163 164 169 UNI GY -13.812
101. 1 TO 4 95 TO 98 139 141 165 167 UNI GY -15.519
102. 5 7 11 99 TO 102 149 179 187 UNI GY -15.521
103. 22 24 26 112 TO 114 140 158 166 174 183 191 UNI GY -17.012
104. 156 185 UNI GY -8.244
105. 155 186 UNI GY -6.857
106. 23 25 27 106 TO 108 142 160 168 176 181 189 UNI GY -15.635
107. 6 8 12 91 TO 94 147 177 188 UNI GY -15.521
108. 144 162 170 172 UNI GY -8.396
109. LOAD 2 LOADTYPE LIVE REDUCIBLE TITLE LL 1
110. MEMBER LOAD
111. 1 3 4 13 15 16 UNI GY -2.38
112. 28 148 161 UNI GY -5.33
113. 192 UNI GY -4.75
114. 18 21 143 UNI GY -5.23
115. 7 8 147 149 UNI GY -2.68
116. 26 140 191 UNI GY -5.3
117. 156 UNI GY -6.19
118. 162 UNI GY -6.3
119. 27 142 189 UNI GY -4.61
120. LOAD 3 LOADTYPE LIVE REDUCIBLE TITLE LL 2
121. MEMBER LOAD
122. 2 14 139 141 157 159 UNI GY -2.38
123. 29 30 150 UNI GY -5.33
124. 190 UNI GY -4.75
125. 17 19 20 UNI GY -5.23
126. 5 6 11 12 187 188 UNI GY -2.68
127. 22 24 158 UNI GY -5.3
128. 144 UNI GY -6.3
129. 155 UNI GY -5.72
130. 23 25 160 UNI GY -4.61
131. LOAD 4 LOADTYPE LIVE REDUCIBLE TITLE LL 3
132. MEMBER LOAD
133. 87 89 90 96 165 167 UNI GY -2.38
134. 103 171 178 UNI GY -5.33
135. 184 UNI GY -4.75
136. 110 111 164 UNI GY -2.97
137. 91 93 100 179 UNI GY -2.68
138. 114 166 183 UNI GY -5
139. 185 UNI GY -5.72
140. 172 UNI GY -6.3
141. 106 107 168 UNI GY -4.61
142. LOAD 5 LOADTYPE LIVE REDUCIBLE TITLE LL 4
STAAD SPACE -- PAGE NO. 4

143. MEMBER LOAD


144. 88 96 TO 98 167 173 175 UNI GY -2.38
145. 104 105 180 UNI GY -5.33
146. 182 UNI GY -4.75
147. 109 163 169 UNI GY -2.97
148. 92 94 99 101 102 177 UNI GY -2.68
149. 112 113 174 UNI GY -5
150. 186 UNI GY -5.72
151. 170 UNI GY -6.3
152. 108 176 181 UNI GY -4.61
153. LOAD 6 LOADTYPE ROOF LIVE TITLE RLL
154. JOINT LOAD
155. 88 90 92 94 122 124 FX 58.367 FY -37.121
156. 85 89 91 93 121 123 FX -58.367 FY -37.121
157. LOAD 7 LOADTYPE WIND TITLE WL +X
158. WIND LOAD X 1 TYPE 1 XR 0 20 YR -3 10 ZR -20 0
159. LOAD 8 LOADTYPE WIND TITLE WL -X
160. WIND LOAD X -1 TYPE 1 XR 0 20 YR -3 10 ZR -20 0
161. LOAD 9 LOADTYPE WIND TITLE WL +Z
162. WIND LOAD Z 1 TYPE 1 XR 0 20 YR -3 10 ZR -20 0
163. LOAD 10 LOADTYPE WIND TITLE WL -Z
164. WIND LOAD Z -1 TYPE 1 XR 0 20 YR -3 10 ZR -20 0
165. LOAD COMB 11 1.4 DL
166. 1 1.4
167. LOAD COMB 12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
168. 1 1.2 2 1.6 5 1.6 6 0.5
169. LOAD COMB 13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
170. 1 1.2 3 1.6 4 1.6 6 0.5
171. LOAD COMB 14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
172. 1 1.2 6 1.6 2 1.0 5 1.0
173. LOAD COMB 15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
174. 1 1.2 6 1.6 3 1.0 4 1.0
175. LOAD COMB 16 1.2 DL + 1.6 RLL + 0.8 WL +X
176. 1 1.2 6 1.6 7 0.8
177. LOAD COMB 17 1.2 DL + 1.6 RLL + 0.8 WL -X
178. 1 1.2 6 1.6 8 0.8
179. LOAD COMB 18 1.2 DL + 1.6 RLL + 0.8 WL +Z
180. 1 1.2 6 1.6 9 0.8
181. LOAD COMB 19 1.2 DL + 1.6 RLL + 0.8 WL -Z
182. 1 1.2 6 1.6 10 0.8
183. LOAD COMB 20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
184. 1 1.2 7 1.6 2 1.0 5 1.0 6 0.5
185. LOAD COMB 21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
186. 1 1.2 7 1.6 3 1.0 4 1.0 6 0.5
STAAD SPACE -- PAGE NO. 5

187. LOAD COMB 22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


188. 1 1.2 8 1.6 2 1.0 5 1.0 6 0.5
189. LOAD COMB 23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
190. 1 1.2 8 1.6 3 1.0 4 1.0 6 0.5
191. LOAD COMB 24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
192. 1 1.2 9 1.6 2 1.0 5 1.0 6 0.5
193. LOAD COMB 25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
194. 1 1.2 9 1.6 3 1.0 4 1.0 6 0.5
195. LOAD COMB 26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
196. 1 1.2 10 1.6 2 1.0 5 1.0 6 0.5
197. LOAD COMB 27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
198. 1 1.2 10 1.6 3 1.0 4 1.0 6 0.5
199. PERFORM ANALYSIS

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 120 NUMBER OF MEMBERS 190


NUMBER OF PLATES 0 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 28

SOLVER USED IS THE OUT-OF-CORE BASIC SOLVER

ORIGINAL/FINAL BAND-WIDTH= 108/ 19/ 105 DOF


TOTAL PRIMARY LOAD CASES = 10, TOTAL DEGREES OF FREEDOM = 636
TOTAL LOAD COMBINATION CASES = 17 SO FAR.
SIZE OF STIFFNESS MATRIX = 67 DOUBLE KILO-WORDS
REQRD/AVAIL. DISK SPACE = 13.1/1466548.5 MB

200. LOAD LIST 1 TO 6


201. PERFORM ANALYSIS PRINT ALL

** ALL CASES BEING MADE ACTIVE BEFORE RE-ANALYSIS. **


STAAD SPACE -- PAGE NO. 6

LOADING 1 LOADTYPE DEAD TITLE DL


-----------

MEMBER LOAD - UNIT KN METE

MEMBER UDL L1 L2 CON L LIN1 LIN2

13 -15.5140 GY 0.00 2.50


14 -15.5140 GY 0.00 5.00
15 -15.5140 GY 0.00 5.00
16 -15.5140 GY 0.00 2.50
87 -15.5140 GY 0.00 2.50
88 -15.5140 GY 0.00 5.00
89 -15.5140 GY 0.00 5.00
90 -15.5140 GY 0.00 2.50
157 -15.5140 GY 0.00 2.50
159 -15.5140 GY 0.00 2.50
173 -15.5140 GY 0.00 2.50
175 -15.5140 GY 0.00 2.50
28 -18.6740 GY 0.00 5.00
29 -18.6740 GY 0.00 2.50
30 -18.6740 GY 0.00 5.00
103 -18.6740 GY 0.00 5.00
104 -18.6740 GY 0.00 2.50
105 -18.6740 GY 0.00 5.00
148 -18.6740 GY 0.00 2.50
150 -18.6740 GY 0.00 2.50
161 -18.6740 GY 0.00 2.50
171 -18.6740 GY 0.00 2.50
178 -18.6740 GY 0.00 2.50
180 -18.6740 GY 0.00 2.50
182 -10.3340 GY 0.00 2.50
184 -10.3340 GY 0.00 2.50
190 -10.3340 GY 0.00 2.50
192 -10.3340 GY 0.00 2.50
17 -13.8120 GY 0.00 2.50
18 -13.8120 GY 0.00 5.00
19 -13.8120 GY 0.00 2.50
20 -13.8120 GY 0.00 5.00
21 -13.8120 GY 0.00 2.50
109 -13.8120 GY 0.00 5.00
110 -13.8120 GY 0.00 2.50
111 -13.8120 GY 0.00 5.00
143 -13.8120 GY 0.00 2.50
163 -13.8120 GY 0.00 2.50
164 -13.8120 GY 0.00 2.50
169 -13.8120 GY 0.00 2.50
1 -15.5190 GY 0.00 2.50
2 -15.5190 GY 0.00 5.00
3 -15.5190 GY 0.00 5.00
4 -15.5190 GY 0.00 2.50
95 -15.5190 GY 0.00 2.50
96 -15.5190 GY 0.00 5.00
STAAD SPACE -- PAGE NO. 7

97 -15.5190 GY 0.00 5.00


98 -15.5190 GY 0.00 2.50
139 -15.5190 GY 0.00 2.50
141 -15.5190 GY 0.00 2.50
165 -15.5190 GY 0.00 2.50
167 -15.5190 GY 0.00 2.50
5 -15.5210 GY 0.00 5.00
7 -15.5210 GY 0.00 5.00
11 -15.5210 GY 0.00 2.50
99 -15.5210 GY 0.00 5.00
100 -15.5210 GY 0.00 5.00
101 -15.5210 GY 0.00 5.00
102 -15.5210 GY 0.00 2.50
149 -15.5210 GY 0.00 2.50
179 -15.5210 GY 0.00 2.50
187 -15.5210 GY 0.00 5.00
22 -17.0120 GY 0.00 2.50
24 -17.0120 GY 0.00 2.50
26 -17.0120 GY 0.00 5.00
112 -17.0120 GY 0.00 2.50
113 -17.0120 GY 0.00 2.50
114 -17.0120 GY 0.00 5.00
140 -17.0120 GY 0.00 5.00
158 -17.0120 GY 0.00 2.50
166 -17.0120 GY 0.00 5.00
174 -17.0120 GY 0.00 2.50
183 -17.0120 GY 0.00 2.50
191 -17.0120 GY 0.00 2.50
156 -8.2440 GY 0.00 12.50
185 -8.2440 GY 0.00 12.50
155 -6.8570 GY 0.00 12.50
186 -6.8570 GY 0.00 12.50
23 -15.6350 GY 0.00 2.50
25 -15.6350 GY 0.00 2.50
27 -15.6350 GY 0.00 5.00
106 -15.6350 GY 0.00 5.00
107 -15.6350 GY 0.00 2.50
108 -15.6350 GY 0.00 2.50
142 -15.6350 GY 0.00 5.00
160 -15.6350 GY 0.00 2.50
168 -15.6350 GY 0.00 5.00
176 -15.6350 GY 0.00 2.50
181 -15.6350 GY 0.00 2.50
189 -15.6350 GY 0.00 2.50
6 -15.5210 GY 0.00 5.00
8 -15.5210 GY 0.00 5.00
12 -15.5210 GY 0.00 2.50
91 -15.5210 GY 0.00 2.50
92 -15.5210 GY 0.00 5.00
93 -15.5210 GY 0.00 5.00
94 -15.5210 GY 0.00 5.00
147 -15.5210 GY 0.00 2.50
177 -15.5210 GY 0.00 2.50
188 -15.5210 GY 0.00 5.00
144 -8.3960 GY 0.00 5.00
162 -8.3960 GY 0.00 2.50
STAAD SPACE -- PAGE NO. 8

170 -8.3960 GY 0.00 5.00


172 -8.3960 GY 0.00 2.50

LOADING 2 LOADTYPE LIVE REDUCIBLE TITLE LL 1


-----------

MEMBER LOAD - UNIT KN METE

MEMBER UDL L1 L2 CON L LIN1 LIN2

1 -2.3800 GY 0.00 2.50


3 -2.3800 GY 0.00 5.00
4 -2.3800 GY 0.00 2.50
13 -2.3800 GY 0.00 2.50
15 -2.3800 GY 0.00 5.00
16 -2.3800 GY 0.00 2.50
28 -5.3300 GY 0.00 5.00
148 -5.3300 GY 0.00 2.50
161 -5.3300 GY 0.00 2.50
192 -4.7500 GY 0.00 2.50
18 -5.2300 GY 0.00 5.00
21 -5.2300 GY 0.00 2.50
143 -5.2300 GY 0.00 2.50
7 -2.6800 GY 0.00 5.00
8 -2.6800 GY 0.00 5.00
147 -2.6800 GY 0.00 2.50
149 -2.6800 GY 0.00 2.50
26 -5.3000 GY 0.00 5.00
140 -5.3000 GY 0.00 5.00
191 -5.3000 GY 0.00 2.50
156 -6.1900 GY 0.00 12.50
162 -6.3000 GY 0.00 2.50
27 -4.6100 GY 0.00 5.00
142 -4.6100 GY 0.00 5.00
189 -4.6100 GY 0.00 2.50

LOADING 3 LOADTYPE LIVE REDUCIBLE TITLE LL 2


-----------

MEMBER LOAD - UNIT KN METE

MEMBER UDL L1 L2 CON L LIN1 LIN2

2 -2.3800 GY 0.00 5.00


14 -2.3800 GY 0.00 5.00
139 -2.3800 GY 0.00 2.50
141 -2.3800 GY 0.00 2.50
157 -2.3800 GY 0.00 2.50
159 -2.3800 GY 0.00 2.50
29 -5.3300 GY 0.00 2.50
30 -5.3300 GY 0.00 5.00
150 -5.3300 GY 0.00 2.50
STAAD SPACE -- PAGE NO. 9

190 -4.7500 GY 0.00 2.50


17 -5.2300 GY 0.00 2.50
19 -5.2300 GY 0.00 2.50
20 -5.2300 GY 0.00 5.00
5 -2.6800 GY 0.00 5.00
6 -2.6800 GY 0.00 5.00
11 -2.6800 GY 0.00 2.50
12 -2.6800 GY 0.00 2.50
187 -2.6800 GY 0.00 5.00
188 -2.6800 GY 0.00 5.00
22 -5.3000 GY 0.00 2.50
24 -5.3000 GY 0.00 2.50
158 -5.3000 GY 0.00 2.50
144 -6.3000 GY 0.00 5.00
155 -5.7200 GY 0.00 12.50
23 -4.6100 GY 0.00 2.50
25 -4.6100 GY 0.00 2.50
160 -4.6100 GY 0.00 2.50

LOADING 4 LOADTYPE LIVE REDUCIBLE TITLE LL 3


-----------

MEMBER LOAD - UNIT KN METE

MEMBER UDL L1 L2 CON L LIN1 LIN2

87 -2.3800 GY 0.00 2.50


89 -2.3800 GY 0.00 5.00
90 -2.3800 GY 0.00 2.50
96 -2.3800 GY 0.00 5.00
165 -2.3800 GY 0.00 2.50
167 -2.3800 GY 0.00 2.50
103 -5.3300 GY 0.00 5.00
171 -5.3300 GY 0.00 2.50
178 -5.3300 GY 0.00 2.50
184 -4.7500 GY 0.00 2.50
110 -2.9700 GY 0.00 2.50
111 -2.9700 GY 0.00 5.00
164 -2.9700 GY 0.00 2.50
91 -2.6800 GY 0.00 2.50
93 -2.6800 GY 0.00 5.00
100 -2.6800 GY 0.00 5.00
179 -2.6800 GY 0.00 2.50
114 -5.0000 GY 0.00 5.00
166 -5.0000 GY 0.00 5.00
183 -5.0000 GY 0.00 2.50
185 -5.7200 GY 0.00 12.50
172 -6.3000 GY 0.00 2.50
106 -4.6100 GY 0.00 5.00
107 -4.6100 GY 0.00 2.50
168 -4.6100 GY 0.00 5.00
STAAD SPACE -- PAGE NO. 10

LOADING 5 LOADTYPE LIVE REDUCIBLE TITLE LL 4


-----------

MEMBER LOAD - UNIT KN METE

MEMBER UDL L1 L2 CON L LIN1 LIN2

88 -2.3800 GY 0.00 5.00


96 -2.3800 GY 0.00 5.00
97 -2.3800 GY 0.00 5.00
98 -2.3800 GY 0.00 2.50
167 -2.3800 GY 0.00 2.50
173 -2.3800 GY 0.00 2.50
175 -2.3800 GY 0.00 2.50
104 -5.3300 GY 0.00 2.50
105 -5.3300 GY 0.00 5.00
180 -5.3300 GY 0.00 2.50
182 -4.7500 GY 0.00 2.50
109 -2.9700 GY 0.00 5.00
163 -2.9700 GY 0.00 2.50
169 -2.9700 GY 0.00 2.50
92 -2.6800 GY 0.00 5.00
94 -2.6800 GY 0.00 5.00
99 -2.6800 GY 0.00 5.00
101 -2.6800 GY 0.00 5.00
102 -2.6800 GY 0.00 2.50
177 -2.6800 GY 0.00 2.50
112 -5.0000 GY 0.00 2.50
113 -5.0000 GY 0.00 2.50
174 -5.0000 GY 0.00 2.50
186 -5.7200 GY 0.00 12.50
170 -6.3000 GY 0.00 5.00
108 -4.6100 GY 0.00 2.50
176 -4.6100 GY 0.00 2.50
181 -4.6100 GY 0.00 2.50

LOADING 6 LOADTYPE ROOF LIVE TITLE RLL


-----------

JOINT LOAD - UNIT KN METE

JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z

88 58.37 -37.12 0.00 0.00 0.00 0.00


90 58.37 -37.12 0.00 0.00 0.00 0.00
92 58.37 -37.12 0.00 0.00 0.00 0.00
94 58.37 -37.12 0.00 0.00 0.00 0.00
122 58.37 -37.12 0.00 0.00 0.00 0.00
124 58.37 -37.12 0.00 0.00 0.00 0.00
85 -58.37 -37.12 0.00 0.00 0.00 0.00
89 -58.37 -37.12 0.00 0.00 0.00 0.00
STAAD SPACE -- PAGE NO. 11

91 -58.37 -37.12 0.00 0.00 0.00 0.00


93 -58.37 -37.12 0.00 0.00 0.00 0.00
121 -58.37 -37.12 0.00 0.00 0.00 0.00
123 -58.37 -37.12 0.00 0.00 0.00 0.00

LOADING 7 LOADTYPE WIND TITLE WL +X


-----------

JOINT LOAD - UNIT KN METE

JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z

1 20.49 0.00 0.00 0.00 0.00 0.00


6 40.99 0.00 0.00 0.00 0.00 0.00
8 40.99 0.00 0.00 0.00 0.00 0.00
10 35.86 0.00 0.00 0.00 0.00 0.00
12 15.37 0.00 0.00 0.00 0.00 0.00
29 8.78 0.00 0.00 0.00 0.00 0.00
34 17.57 0.00 0.00 0.00 0.00 0.00
36 17.57 0.00 0.00 0.00 0.00 0.00
38 17.57 0.00 0.00 0.00 0.00 0.00
40 8.78 0.00 0.00 0.00 0.00 0.00
57 11.71 0.00 0.00 0.00 0.00 0.00
62 23.42 0.00 0.00 0.00 0.00 0.00
64 23.42 0.00 0.00 0.00 0.00 0.00
66 20.49 0.00 0.00 0.00 0.00 0.00
68 8.78 0.00 0.00 0.00 0.00 0.00
73 4.45 0.00 0.00 0.00 0.00 0.00
77 11.15 0.00 0.00 0.00 0.00 0.00
79 15.60 0.00 0.00 0.00 0.00 0.00
81 8.90 0.00 0.00 0.00 0.00 0.00
85 4.62 0.00 0.00 0.00 0.00 0.00
89 11.53 0.00 0.00 0.00 0.00 0.00
91 13.83 0.00 0.00 0.00 0.00 0.00
93 6.91 0.00 0.00 0.00 0.00 0.00
103 10.25 0.00 0.00 0.00 0.00 0.00
116 5.86 0.00 0.00 0.00 0.00 0.00
118 2.97 0.00 0.00 0.00 0.00 0.00
121 0.94 0.00 0.00 0.00 0.00 0.00
123 0.94 0.00 0.00 0.00 0.00 0.00

LOADING 8 LOADTYPE WIND TITLE WL -X


-----------

JOINT LOAD - UNIT KN METE

JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z

5 -20.49 0.00 0.00 0.00 0.00 0.00


7 -40.99 0.00 0.00 0.00 0.00 0.00
9 -40.99 0.00 0.00 0.00 0.00 0.00
11 -35.86 0.00 0.00 0.00 0.00 0.00
STAAD SPACE -- PAGE NO. 12

13 -15.37 0.00 0.00 0.00 0.00 0.00


33 -8.78 0.00 0.00 0.00 0.00 0.00
35 -17.57 0.00 0.00 0.00 0.00 0.00
37 -17.57 0.00 0.00 0.00 0.00 0.00
39 -17.57 0.00 0.00 0.00 0.00 0.00
41 -8.78 0.00 0.00 0.00 0.00 0.00
61 -11.71 0.00 0.00 0.00 0.00 0.00
63 -23.42 0.00 0.00 0.00 0.00 0.00
65 -23.42 0.00 0.00 0.00 0.00 0.00
67 -20.49 0.00 0.00 0.00 0.00 0.00
69 -8.78 0.00 0.00 0.00 0.00 0.00
76 -4.45 0.00 0.00 0.00 0.00 0.00
78 -11.15 0.00 0.00 0.00 0.00 0.00
80 -15.60 0.00 0.00 0.00 0.00 0.00
82 -8.90 0.00 0.00 0.00 0.00 0.00
88 -4.62 0.00 0.00 0.00 0.00 0.00
90 -11.53 0.00 0.00 0.00 0.00 0.00
92 -13.83 0.00 0.00 0.00 0.00 0.00
94 -6.91 0.00 0.00 0.00 0.00 0.00
102 -10.25 0.00 0.00 0.00 0.00 0.00
115 -5.86 0.00 0.00 0.00 0.00 0.00
117 -2.97 0.00 0.00 0.00 0.00 0.00
122 -0.94 0.00 0.00 0.00 0.00 0.00
124 -0.94 0.00 0.00 0.00 0.00 0.00

LOADING 9 LOADTYPE WIND TITLE WL +Z


-----------

JOINT LOAD - UNIT KN METE

JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z

12 0.00 0.00 15.37 0.00 0.00 0.00


13 0.00 0.00 15.37 0.00 0.00 0.00
14 0.00 0.00 35.86 0.00 0.00 0.00
15 0.00 0.00 40.99 0.00 0.00 0.00
16 0.00 0.00 35.86 0.00 0.00 0.00
40 0.00 0.00 8.78 0.00 0.00 0.00
41 0.00 0.00 8.78 0.00 0.00 0.00
42 0.00 0.00 17.57 0.00 0.00 0.00
43 0.00 0.00 17.57 0.00 0.00 0.00
44 0.00 0.00 17.57 0.00 0.00 0.00
68 0.00 0.00 8.78 0.00 0.00 0.00
69 0.00 0.00 8.78 0.00 0.00 0.00
70 0.00 0.00 20.49 0.00 0.00 0.00
71 0.00 0.00 23.42 0.00 0.00 0.00
72 0.00 0.00 20.49 0.00 0.00 0.00
81 0.00 0.00 8.90 0.00 0.00 0.00
82 0.00 0.00 8.90 0.00 0.00 0.00
83 0.00 0.00 15.60 0.00 0.00 0.00
84 0.00 0.00 15.60 0.00 0.00 0.00
93 0.00 0.00 9.24 0.00 0.00 0.00
94 0.00 0.00 9.24 0.00 0.00 0.00
95 0.00 0.00 18.47 0.00 0.00 0.00
STAAD SPACE -- PAGE NO. 13

96 0.00 0.00 18.47 0.00 0.00 0.00


106 0.00 0.00 10.25 0.00 0.00 0.00
107 0.00 0.00 10.25 0.00 0.00 0.00
112 0.00 0.00 2.97 0.00 0.00 0.00
113 0.00 0.00 5.86 0.00 0.00 0.00
114 0.00 0.00 5.86 0.00 0.00 0.00

LOADING 10 LOADTYPE WIND TITLE WL -Z


-----------

JOINT LOAD - UNIT KN METE

JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z

1 0.00 0.00 -15.37 0.00 0.00 0.00


2 0.00 0.00 -35.86 0.00 0.00 0.00
3 0.00 0.00 -40.99 0.00 0.00 0.00
4 0.00 0.00 -35.86 0.00 0.00 0.00
5 0.00 0.00 -15.37 0.00 0.00 0.00
29 0.00 0.00 -8.78 0.00 0.00 0.00
30 0.00 0.00 -17.57 0.00 0.00 0.00
31 0.00 0.00 -17.57 0.00 0.00 0.00
32 0.00 0.00 -17.57 0.00 0.00 0.00
33 0.00 0.00 -8.78 0.00 0.00 0.00
57 0.00 0.00 -8.78 0.00 0.00 0.00
58 0.00 0.00 -20.49 0.00 0.00 0.00
59 0.00 0.00 -23.42 0.00 0.00 0.00
60 0.00 0.00 -20.49 0.00 0.00 0.00
61 0.00 0.00 -8.78 0.00 0.00 0.00
73 0.00 0.00 -8.90 0.00 0.00 0.00
74 0.00 0.00 -15.60 0.00 0.00 0.00
75 0.00 0.00 -15.60 0.00 0.00 0.00
76 0.00 0.00 -8.90 0.00 0.00 0.00
85 0.00 0.00 -9.24 0.00 0.00 0.00
86 0.00 0.00 -18.47 0.00 0.00 0.00
87 0.00 0.00 -18.47 0.00 0.00 0.00
88 0.00 0.00 -9.24 0.00 0.00 0.00
97 0.00 0.00 -10.25 0.00 0.00 0.00
98 0.00 0.00 -10.25 0.00 0.00 0.00
109 0.00 0.00 -5.86 0.00 0.00 0.00
110 0.00 0.00 -5.86 0.00 0.00 0.00
111 0.00 0.00 -2.97 0.00 0.00 0.00

FOR LOADING - 1
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 0.00000E+00-5.82013E+01 0.00000E+00-3.23354E+01 0.00000E+00-8.08281E+00
2 0.00000E+00-5.81963E+01 0.00000E+00 0.00000E+00 0.00000E+00-2.42484E+01
3 0.00000E+00-9.85850E+01 0.00000E+00-1.74917E+01 0.00000E+00 0.00000E+00
4 0.00000E+00-5.81963E+01 0.00000E+00 0.00000E+00 0.00000E+00 2.42484E+01
5 0.00000E+00-5.82013E+01 0.00000E+00-3.23354E+01 0.00000E+00 8.08282E+00
6 0.00000E+00-9.48700E+01 0.00000E+00 0.00000E+00 0.00000E+00-7.19375E+00
7 0.00000E+00-9.48700E+01 0.00000E+00 0.00000E+00 0.00000E+00 7.19375E+00
STAAD SPACE -- PAGE NO. 14

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
8 0.00000E+00-9.05225E+01 0.00000E+00 0.00000E+00 0.00000E+00-5.38229E+00
9 0.00000E+00-9.05225E+01 0.00000E+00 0.00000E+00 0.00000E+00 5.38230E+00
10 0.00000E+00-5.82037E+01 0.00000E+00 2.42516E+01 0.00000E+00 0.00000E+00
11 0.00000E+00-5.82037E+01 0.00000E+00 2.42516E+01 0.00000E+00 0.00000E+00
12 0.00000E+00-3.87938E+01 0.00000E+00 8.08386E+00 0.00000E+00-8.08021E+00
13 0.00000E+00-3.87938E+01 0.00000E+00 8.08386E+00 0.00000E+00 8.08021E+00
14 0.00000E+00-5.81775E+01 0.00000E+00 0.00000E+00 0.00000E+00-2.42406E+01
15 0.00000E+00-8.80650E+01 0.00000E+00 4.37292E+00 0.00000E+00 0.00000E+00
16 0.00000E+00-5.81775E+01 0.00000E+00 0.00000E+00 0.00000E+00 2.42406E+01
17 0.00000E+00-1.15590E+02 0.00000E+00 2.65813E+01 0.00000E+00-2.15813E+01
18 0.00000E+00-1.03320E+02 0.00000E+00-1.07344E+02 0.00000E+00 2.15813E+01
19 0.00000E+00-9.46513E+01 0.00000E+00-8.92839E+01 0.00000E+00-2.15813E+01
20 0.00000E+00-1.10426E+02 0.00000E+00 2.44297E+01 0.00000E+00 2.15812E+01
21 0.00000E+00-4.25300E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
22 0.00000E+00-3.90875E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
23 0.00000E+00-6.37950E+01 0.00000E+00-2.65813E+01 0.00000E+00 0.00000E+00
24 0.00000E+00-5.86312E+01 0.00000E+00-2.44297E+01 0.00000E+00 0.00000E+00
25 0.00000E+00-1.33823E+02 0.00000E+00 2.65812E+01 0.00000E+00-2.91781E+01
26 0.00000E+00-1.28659E+02 0.00000E+00 2.44297E+01 0.00000E+00 2.91781E+01
27 0.00000E+00-1.21553E+02 0.00000E+00 1.07344E+02 0.00000E+00 2.91781E+01
28 0.00000E+00-1.12884E+02 0.00000E+00 8.92839E+01 0.00000E+00-2.91781E+01
57 0.00000E+00-5.82013E+01 0.00000E+00-3.23354E+01 0.00000E+00-8.08281E+00
58 0.00000E+00-5.81963E+01 0.00000E+00 0.00000E+00 0.00000E+00-2.42484E+01
59 0.00000E+00-9.85850E+01 0.00000E+00-1.74917E+01 0.00000E+00 0.00000E+00
60 0.00000E+00-5.81963E+01 0.00000E+00 0.00000E+00 0.00000E+00 2.42484E+01
61 0.00000E+00-5.82013E+01 0.00000E+00-3.23354E+01 0.00000E+00 8.08282E+00
62 0.00000E+00-9.48700E+01 0.00000E+00 0.00000E+00 0.00000E+00-7.19375E+00
63 0.00000E+00-9.48700E+01 0.00000E+00 0.00000E+00 0.00000E+00 7.19375E+00
64 0.00000E+00-9.05225E+01 0.00000E+00 0.00000E+00 0.00000E+00-5.38229E+00
65 0.00000E+00-9.05225E+01 0.00000E+00 0.00000E+00 0.00000E+00 5.38230E+00
66 0.00000E+00-5.82037E+01 0.00000E+00 2.42516E+01 0.00000E+00 0.00000E+00
67 0.00000E+00-5.82037E+01 0.00000E+00 2.42516E+01 0.00000E+00 0.00000E+00
68 0.00000E+00-3.87938E+01 0.00000E+00 8.08386E+00 0.00000E+00-8.08021E+00
69 0.00000E+00-3.87938E+01 0.00000E+00 8.08386E+00 0.00000E+00 8.08021E+00
70 0.00000E+00-5.81775E+01 0.00000E+00 0.00000E+00 0.00000E+00-2.42406E+01
71 0.00000E+00-8.80650E+01 0.00000E+00 4.37292E+00 0.00000E+00 0.00000E+00
72 0.00000E+00-5.81775E+01 0.00000E+00 0.00000E+00 0.00000E+00 2.42406E+01
73 0.00000E+00-1.15590E+02 0.00000E+00 2.65813E+01 0.00000E+00-2.15813E+01
74 0.00000E+00-1.03320E+02 0.00000E+00-1.07344E+02 0.00000E+00 2.15813E+01
75 0.00000E+00-9.46512E+01 0.00000E+00-8.92839E+01 0.00000E+00-2.15813E+01
76 0.00000E+00-1.10426E+02 0.00000E+00 2.44297E+01 0.00000E+00 2.15812E+01
77 0.00000E+00-4.25300E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
78 0.00000E+00-3.90875E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
79 0.00000E+00-6.37950E+01 0.00000E+00-2.65813E+01 0.00000E+00 0.00000E+00
80 0.00000E+00-5.86312E+01 0.00000E+00-2.44297E+01 0.00000E+00 0.00000E+00
81 0.00000E+00-1.33823E+02 0.00000E+00 2.65812E+01 0.00000E+00-2.91781E+01
82 0.00000E+00-1.28659E+02 0.00000E+00 2.44297E+01 0.00000E+00 2.91781E+01
83 0.00000E+00-1.21553E+02 0.00000E+00 1.07344E+02 0.00000E+00 2.91781E+01
84 0.00000E+00-1.12884E+02 0.00000E+00 8.92839E+01 0.00000E+00-2.91781E+01
97 0.00000E+00-8.13275E+01 0.00000E+00-3.54417E+01 0.00000E+00 0.00000E+00
98 0.00000E+00-7.78850E+01 0.00000E+00-3.25729E+01 0.00000E+00-9.48206E-06
99 0.00000E+00-5.55200E+01 0.00000E+00 1.74917E+01 0.00000E+00 4.31003E-06
102 0.00000E+00-6.21450E+01 0.00000E+00-9.48206E-06 0.00000E+00 9.72605E+00
STAAD SPACE -- PAGE NO. 15

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
103 0.00000E+00-6.21450E+01 0.00000E+00-9.48206E-06 0.00000E+00-9.72604E+00
106 0.00000E+00-6.00500E+01 0.00000E+00 8.86042E+00 0.00000E+00 0.00000E+00
107 0.00000E+00-5.83288E+01 0.00000E+00 8.14323E+00 0.00000E+00-8.62006E-06
108 0.00000E+00-5.71800E+01 0.00000E+00-4.37292E+00 0.00000E+00 6.03404E-06
109 0.00000E+00-8.13275E+01 0.00000E+00-3.54417E+01 0.00000E+00 0.00000E+00
110 0.00000E+00-7.78850E+01 0.00000E+00-3.25729E+01 0.00000E+00-9.48206E-06
111 0.00000E+00-5.55200E+01 0.00000E+00 1.74917E+01 0.00000E+00 4.31003E-06
112 0.00000E+00-5.71800E+01 0.00000E+00-4.37292E+00 0.00000E+00 6.03404E-06
113 0.00000E+00-6.00500E+01 0.00000E+00 8.86042E+00 0.00000E+00 0.00000E+00
114 0.00000E+00-5.83288E+01 0.00000E+00 8.14323E+00 0.00000E+00-8.62006E-06
115 0.00000E+00-6.21450E+01 0.00000E+00-9.48206E-06 0.00000E+00 9.72605E+00
116 0.00000E+00-6.21450E+01 0.00000E+00-9.48206E-06 0.00000E+00-9.72604E+00
117 0.00000E+00-5.20050E+01 0.00000E+00 5.17204E-06 0.00000E+00-5.38230E+00
118 0.00000E+00-5.54475E+01 0.00000E+00 5.17204E-06 0.00000E+00 5.38229E+00
119 0.00000E+00-5.20050E+01 0.00000E+00 5.17204E-06 0.00000E+00-5.38230E+00
120 0.00000E+00-5.54475E+01 0.00000E+00 5.17204E-06 0.00000E+00 5.38229E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 1


LOADTYPE DEAD TITLE DL

CENTER OF FORCE BASED ON Y FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.991224314E+01
Y = 0.199999999E+01
Z = -0.105350774E+02

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 1 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -5695.13
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -59998.59 MY= 0.00 MZ= -56451.47

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 1 )


SUMMATION FORCE-X = -0.00
SUMMATION FORCE-Y = 5695.13
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 59998.59 MY= -0.00 MZ= 56451.47
STAAD SPACE -- PAGE NO. 16

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 1)


MAXIMUMS AT NODE
X = 1.79708E-01 64
Y = -4.53430E-01 109
Z = 9.48075E-02 71
RX= -1.62322E-03 109
RY= 4.33602E-04 123
RZ= -8.79802E-04 120

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 0.00 0.00 0.00 0.00 0.00 0.00
-6.34 -186.49 4.65 -0.00 0.00 -0.00 111000

30 0.00 0.00 0.00 0.00 0.00 0.00


1.74 -190.56 1.32 0.00 0.00 -0.00 111000

31 0.00 0.00 0.00 0.00 0.00 0.00


0.01 -204.42 6.37 -0.00 -0.00 -0.00 111000

32 0.00 0.00 0.00 0.00 0.00 0.00


-1.54 -187.67 1.21 0.00 -0.00 -0.00 111000

33 0.00 0.00 0.00 0.00 0.00 0.00


6.15 -183.69 4.58 0.00 0.00 -0.00 111000

34 0.00 0.00 0.00 0.00 0.00 0.00


-1.03 -188.84 0.56 -0.00 0.00 0.00 111000

35 0.00 0.00 0.00 0.00 0.00 0.00


1.06 -188.97 0.53 0.00 -0.00 -0.00 111000

36 0.00 0.00 0.00 0.00 0.00 0.00


-4.28 -199.58 0.24 -0.00 -0.00 0.00 111000

37 0.00 0.00 0.00 0.00 0.00 0.00


4.10 -198.63 0.21 -0.00 0.00 0.00 111000

38 0.00 0.00 0.00 0.00 0.00 0.00


0.64 -164.83 0.43 -0.00 -0.00 -0.00 111000

39 0.00 0.00 0.00 0.00 0.00 0.00


-0.64 -164.82 0.41 0.00 0.00 0.00 111000

40 0.00 0.00 0.00 0.00 0.00 0.00


-4.15 -167.59 -4.09 -0.00 0.00 0.00 111000

41 0.00 0.00 0.00 0.00 0.00 0.00


4.09 -166.61 -4.11 -0.00 -0.00 -0.00 111000

42 0.00 0.00 0.00 0.00 0.00 0.00


0.13 -163.03 0.48 -0.00 0.00 0.00 111000

43 0.00 0.00 0.00 0.00 0.00 0.00


0.01 -194.73 -5.06 0.00 -0.00 -0.00 111000

44 0.00 0.00 0.00 0.00 0.00 0.00


-0.04 -161.91 0.48 0.00 -0.00 -0.00 111000
STAAD SPACE -- PAGE NO. 17

49 0.00 0.00 0.00 0.00 0.00 0.00


-0.48 -129.91 3.57 -0.00 -0.00 -0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


0.45 -120.36 3.33 0.00 -0.00 0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


-0.64 -174.46 -0.32 -0.00 -0.00 0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


0.60 -161.13 -0.36 0.00 -0.00 0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


-1.00 -325.45 -0.81 0.00 0.00 -0.00 111000

54 0.00 0.00 0.00 0.00 0.00 0.00


1.01 -313.98 -0.61 0.00 -0.00 -0.00 111000

55 0.00 0.00 0.00 0.00 0.00 0.00


-0.01 -290.84 -15.76 0.00 -0.00 -0.00 111000

56 0.00 0.00 0.00 0.00 0.00 0.00


0.04 -273.64 -13.22 0.00 0.00 -0.00 111000

FOR LOADING - 2
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.23958E+00
3 0.00000E+00-5.95000E+00 0.00000E+00 0.00000E+00 0.00000E+00-4.95833E+00
4 0.00000E+00-8.92500E+00 0.00000E+00 0.00000E+00 0.00000E+00 3.71875E+00
6 0.00000E+00-6.70000E+00 0.00000E+00-5.58333E+00 0.00000E+00 0.00000E+00
7 0.00000E+00-1.32375E+01 0.00000E+00-5.58333E+00 0.00000E+00 2.72396E+00
8 0.00000E+00-1.26375E+01 0.00000E+00 5.58333E+00 0.00000E+00-2.47396E+00
9 0.00000E+00-6.70000E+00 0.00000E+00 5.58333E+00 0.00000E+00 0.00000E+00
12 0.00000E+00-6.32500E+00 0.00000E+00 1.39583E+00 0.00000E+00-1.23958E+00
13 0.00000E+00-3.35000E+00 0.00000E+00 1.39583E+00 0.00000E+00 0.00000E+00
15 0.00000E+00-1.38250E+01 0.00000E+00 3.28125E+00 0.00000E+00-4.95833E+00
16 0.00000E+00-8.92500E+00 0.00000E+00 0.00000E+00 0.00000E+00 3.71875E+00
17 0.00000E+00-2.63250E+01 0.00000E+00 1.10417E+01 0.00000E+00-1.08958E+01
18 0.00000E+00-5.17625E+01 0.00000E+00-8.05990E+01 0.00000E+00 1.08958E+01
19 0.00000E+00-6.53750E+00 0.00000E+00 0.00000E+00 0.00000E+00 2.72396E+00
20 0.00000E+00-1.80625E+01 0.00000E+00 9.60417E+00 0.00000E+00-2.72396E+00
23 0.00000E+00-1.98750E+01 0.00000E+00-8.28125E+00 0.00000E+00 0.00000E+00
24 0.00000E+00-1.72875E+01 0.00000E+00-7.20313E+00 0.00000E+00 0.00000E+00
25 0.00000E+00-2.65750E+01 0.00000E+00 1.10417E+01 0.00000E+00-1.11042E+01
26 0.00000E+00-1.81875E+01 0.00000E+00 9.60417E+00 0.00000E+00-2.77604E+00
27 0.00000E+00-5.20125E+01 0.00000E+00 8.05990E+01 0.00000E+00 1.11042E+01
28 0.00000E+00-6.66250E+00 0.00000E+00 0.00000E+00 0.00000E+00 2.77604E+00
97 0.00000E+00-1.62250E+01 0.00000E+00-1.10417E+01 0.00000E+00 1.23958E+00
98 0.00000E+00-1.45000E+01 0.00000E+00-9.60417E+00 0.00000E+00 1.23958E+00
99 0.00000E+00-6.53750E+00 0.00000E+00 0.00000E+00 0.00000E+00-2.72396E+00
102 0.00000E+00-1.00125E+01 0.00000E+00-1.39583E+00 0.00000E+00 2.77604E+00
103 0.00000E+00-3.35000E+00 0.00000E+00-1.39583E+00 0.00000E+00 0.00000E+00
106 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.23958E+00
107 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.23958E+00
108 0.00000E+00-1.45375E+01 0.00000E+00-3.28125E+00 0.00000E+00-2.77604E+00
119 0.00000E+00-5.76250E+00 0.00000E+00-2.40104E+00 0.00000E+00 0.00000E+00
120 0.00000E+00-1.25625E+01 0.00000E+00-2.76042E+00 0.00000E+00 2.47396E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 2


LOADTYPE LIVE REDUCIBLE TITLE LL 1
STAAD SPACE -- PAGE NO. 18

CENTER OF FORCE BASED ON Y FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.921311681E+01
Y = 0.000000000E+00
Z = -0.107817775E+02

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 2 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -422.28
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -4552.88 MY= 0.00 MZ= -3890.47

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 2 )


SUMMATION FORCE-X = -0.00
SUMMATION FORCE-Y = 422.28
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 4552.88 MY= -0.00 MZ= 3890.47

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 2)


MAXIMUMS AT NODE
X = 3.10692E-02 91
Y = -8.30967E-02 97
Z = 4.42933E-02 71
RX= -5.84547E-04 97
RY= -6.60228E-05 89
RZ= -1.34598E-04 120

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 0.00 0.00 0.00 0.00 0.00 0.00
-1.78 -10.43 0.47 0.00 0.00 0.00 111000

30 0.00 0.00 0.00 0.00 0.00 0.00


1.56 -6.69 0.35 0.00 0.00 -0.00 111000

31 0.00 0.00 0.00 0.00 0.00 0.00


-0.80 -6.15 0.21 0.00 -0.00 0.00 111000

32 0.00 0.00 0.00 0.00 0.00 0.00


-0.68 -15.61 0.30 0.00 0.00 -0.00 111000

33 0.00 0.00 0.00 0.00 0.00 0.00


1.40 -6.22 0.42 -0.00 0.00 0.00 111000

34 0.00 0.00 0.00 0.00 0.00 0.00


0.01 -6.45 1.16 0.00 0.00 0.00 111000

35 0.00 0.00 0.00 0.00 0.00 0.00


0.49 -13.43 1.15 0.00 -0.00 0.00 111000
STAAD SPACE -- PAGE NO. 19

36 0.00 0.00 0.00 0.00 0.00 0.00


-0.89 -15.18 -0.67 -0.00 -0.00 0.00 111000

37 0.00 0.00 0.00 0.00 0.00 0.00


0.22 -7.60 -0.70 0.00 0.00 0.00 111000

38 0.00 0.00 0.00 0.00 0.00 0.00


0.08 -0.95 0.49 0.00 0.00 -0.00 111000

39 0.00 0.00 0.00 0.00 0.00 0.00


-0.03 -3.46 1.02 -0.00 0.00 -0.00 111000

40 0.00 0.00 0.00 0.00 0.00 0.00


-0.35 -8.53 -0.31 0.00 0.00 0.00 111000

41 0.00 0.00 0.00 0.00 0.00 0.00


0.21 -7.78 -0.89 0.00 0.00 0.00 111000

42 0.00 0.00 0.00 0.00 0.00 0.00


0.30 -0.62 0.11 0.00 -0.00 -0.00 111000

43 0.00 0.00 0.00 0.00 0.00 0.00


-0.78 -16.45 -1.14 0.00 0.00 -0.00 111000

44 0.00 0.00 0.00 0.00 0.00 0.00


0.50 -10.20 0.11 -0.00 0.00 -0.00 111000

45 0.00 0.00 0.00 0.00 0.00 0.00


-1.73 -30.42 -2.08 -0.00 0.00 -0.00 111000

46 0.00 0.00 0.00 0.00 0.00 0.00


1.24 -54.26 14.38 0.00 -0.00 -0.00 111000

47 0.00 0.00 0.00 0.00 0.00 0.00


1.20 -10.54 0.23 0.00 -0.00 -0.00 111000

48 0.00 0.00 0.00 0.00 0.00 0.00


-0.44 -21.40 -1.86 -0.00 -0.00 -0.00 111000

49 0.00 0.00 0.00 0.00 0.00 0.00


0.04 -3.15 1.34 0.00 0.00 0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


0.01 -0.63 0.81 -0.00 -0.00 0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


0.05 -25.72 0.59 -0.00 -0.00 0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


0.01 -20.41 0.91 -0.00 0.00 -0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


-1.50 -28.04 -1.33 0.00 -0.00 0.00 111000

54 0.00 0.00 0.00 0.00 0.00 0.00


-0.99 -21.51 -1.07 0.00 -0.00 -0.00 111000

55 0.00 0.00 0.00 0.00 0.00 0.00


0.81 -57.14 -14.08 0.00 0.00 0.00 111000

56 0.00 0.00 0.00 0.00 0.00 0.00


1.86 -13.29 0.07 -0.00 0.00 0.00 111000

FOR LOADING - 3
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
STAAD SPACE -- PAGE NO. 20

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
13 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.23958E+00
14 0.00000E+00-8.92500E+00 0.00000E+00 0.00000E+00 0.00000E+00-3.71875E+00
15 0.00000E+00-5.95000E+00 0.00000E+00 0.00000E+00 0.00000E+00 4.95833E+00
17 0.00000E+00-1.31625E+01 0.00000E+00-2.76042E+00 0.00000E+00 2.72396E+00
18 0.00000E+00-6.53750E+00 0.00000E+00 0.00000E+00 0.00000E+00-2.72396E+00
19 0.00000E+00-4.88250E+01 0.00000E+00-7.44792E+01 0.00000E+00-1.08958E+01
20 0.00000E+00-1.88375E+01 0.00000E+00-2.40104E+00 0.00000E+00 1.08958E+01
21 0.00000E+00-1.32500E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
22 0.00000E+00-1.15250E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
25 0.00000E+00-1.32875E+01 0.00000E+00-2.76042E+00 0.00000E+00 2.77604E+00
26 0.00000E+00-1.90875E+01 0.00000E+00-2.40104E+00 0.00000E+00 1.11042E+01
27 0.00000E+00-6.66250E+00 0.00000E+00 0.00000E+00 0.00000E+00-2.77604E+00
28 0.00000E+00-4.90750E+01 0.00000E+00 7.44792E+01 0.00000E+00-1.11042E+01
97 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.23958E+00
98 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.23958E+00
99 0.00000E+00-2.22875E+01 0.00000E+00 1.31250E+01 0.00000E+00 2.72396E+00
102 0.00000E+00-3.35000E+00 0.00000E+00 1.39583E+00 0.00000E+00 0.00000E+00
103 0.00000E+00-1.00125E+01 0.00000E+00 1.39583E+00 0.00000E+00-2.77604E+00
106 0.00000E+00-9.60000E+00 0.00000E+00 2.76042E+00 0.00000E+00-1.23958E+00
107 0.00000E+00-8.73750E+00 0.00000E+00 2.40104E+00 0.00000E+00-1.23958E+00
108 0.00000E+00-6.66250E+00 0.00000E+00 0.00000E+00 0.00000E+00 2.77604E+00
119 0.00000E+00-1.17000E+01 0.00000E+00 2.40104E+00 0.00000E+00-2.47396E+00
120 0.00000E+00-6.62500E+00 0.00000E+00 2.76042E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 3


LOADTYPE LIVE REDUCIBLE TITLE LL 2

CENTER OF FORCE BASED ON Y FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.105229454E+02
Y = 0.000000000E+00
Z = -0.100831248E+02

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 3 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -409.40
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -4128.03 MY= 0.00 MZ= -4308.09

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 3 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 409.40
SUMMATION FORCE-Z = -0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 4128.03 MY= -0.00 MZ= 4308.09
STAAD SPACE -- PAGE NO. 21

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 3)


MAXIMUMS AT NODE
X = -2.88142E-02 92
Y = -1.15962E-01 99
Z = -6.20966E-02 59
RX= 6.07871E-04 99
RY= 7.56892E-05 74
RZ= -1.42577E-04 120

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 0.00 0.00 0.00 0.00 0.00 0.00
-0.30 -7.51 0.82 -0.00 -0.00 -0.00 111000

30 0.00 0.00 0.00 0.00 0.00 0.00


-0.37 -10.68 -0.09 0.00 0.00 0.00 111000

31 0.00 0.00 0.00 0.00 0.00 0.00


0.80 -24.18 2.87 0.00 0.00 -0.00 111000

32 0.00 0.00 0.00 0.00 0.00 0.00


-0.35 -1.05 -0.08 0.00 0.00 0.00 111000

33 0.00 0.00 0.00 0.00 0.00 0.00


0.53 -11.00 0.82 -0.00 -0.00 -0.00 111000

34 0.00 0.00 0.00 0.00 0.00 0.00


-0.47 -13.27 -1.19 -0.00 -0.00 -0.00 111000

35 0.00 0.00 0.00 0.00 0.00 0.00


-0.02 -6.34 -1.18 -0.00 0.00 0.00 111000

36 0.00 0.00 0.00 0.00 0.00 0.00


-0.29 -7.75 0.70 0.00 0.00 0.00 111000

37 0.00 0.00 0.00 0.00 0.00 0.00


0.90 -15.08 0.72 0.00 -0.00 -0.00 111000

38 0.00 0.00 0.00 0.00 0.00 0.00


0.02 -14.14 -0.10 0.00 -0.00 -0.00 111000

39 0.00 0.00 0.00 0.00 0.00 0.00


-0.07 -11.63 -0.63 0.00 0.00 -0.00 111000

40 0.00 0.00 0.00 0.00 0.00 0.00


-0.79 -7.12 -0.91 -0.00 0.00 -0.00 111000

41 0.00 0.00 0.00 0.00 0.00 0.00


0.88 -7.63 -0.34 -0.00 0.00 -0.00 111000

42 0.00 0.00 0.00 0.00 0.00 0.00


0.07 -12.97 -0.03 0.00 -0.00 0.00 111000

43 0.00 0.00 0.00 0.00 0.00 0.00


0.78 -7.42 -0.55 0.00 0.00 0.00 111000

44 0.00 0.00 0.00 0.00 0.00 0.00


-0.79 -3.11 -0.03 0.00 0.00 0.00 111000
STAAD SPACE -- PAGE NO. 22

49 0.00 0.00 0.00 0.00 0.00 0.00


-0.01 -17.75 0.34 -0.00 0.00 -0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


-0.04 -17.88 0.70 0.00 -0.00 -0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


-0.03 -2.10 -0.73 0.00 -0.00 0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


-0.04 -4.07 -1.09 -0.00 0.00 0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


0.97 -18.52 0.79 0.00 -0.00 0.00 111000

54 0.00 0.00 0.00 0.00 0.00 0.00


1.52 -22.17 0.63 -0.00 -0.00 -0.00 111000

55 0.00 0.00 0.00 0.00 0.00 0.00


-1.23 -10.07 -0.30 -0.00 0.00 0.00 111000

56 0.00 0.00 0.00 0.00 0.00 0.00


-1.44 -51.00 -13.37 -0.00 0.00 -0.00 111000

FOR LOADING - 4
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
57 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.23958E+00
59 0.00000E+00-5.95000E+00 0.00000E+00 0.00000E+00 0.00000E+00-4.95833E+00
60 0.00000E+00-8.92500E+00 0.00000E+00 0.00000E+00 0.00000E+00 3.71875E+00
62 0.00000E+00-6.70000E+00 0.00000E+00-5.58333E+00 0.00000E+00 0.00000E+00
63 0.00000E+00-1.04125E+01 0.00000E+00-5.58333E+00 0.00000E+00 1.54688E+00
64 0.00000E+00-1.26375E+01 0.00000E+00 5.58333E+00 0.00000E+00-2.47396E+00
65 0.00000E+00-6.70000E+00 0.00000E+00 5.58333E+00 0.00000E+00 0.00000E+00
68 0.00000E+00-6.32500E+00 0.00000E+00 1.39583E+00 0.00000E+00-1.23958E+00
69 0.00000E+00-3.35000E+00 0.00000E+00 1.39583E+00 0.00000E+00 0.00000E+00
71 0.00000E+00-1.38250E+01 0.00000E+00 3.28125E+00 0.00000E+00-4.95833E+00
72 0.00000E+00-8.92500E+00 0.00000E+00 0.00000E+00 0.00000E+00 3.71875E+00
73 0.00000E+00-1.99250E+01 0.00000E+00 1.04167E+01 0.00000E+00-6.18750E+00
74 0.00000E+00-4.31750E+01 0.00000E+00-7.44792E+01 0.00000E+00 6.18750E+00
75 0.00000E+00-3.71250E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.54687E+00
76 0.00000E+00-1.52375E+01 0.00000E+00 9.60417E+00 0.00000E+00-1.54688E+00
79 0.00000E+00-1.87500E+01 0.00000E+00-7.81250E+00 0.00000E+00 0.00000E+00
80 0.00000E+00-1.72875E+01 0.00000E+00-7.20313E+00 0.00000E+00 0.00000E+00
81 0.00000E+00-2.58250E+01 0.00000E+00 1.04167E+01 0.00000E+00-1.11042E+01
82 0.00000E+00-1.81875E+01 0.00000E+00 9.60417E+00 0.00000E+00-2.77604E+00
83 0.00000E+00-4.90750E+01 0.00000E+00 7.44792E+01 0.00000E+00 1.11042E+01
84 0.00000E+00-6.66250E+00 0.00000E+00 0.00000E+00 0.00000E+00 2.77604E+00
109 0.00000E+00-1.54750E+01 0.00000E+00-1.04167E+01 0.00000E+00 1.23958E+00
110 0.00000E+00-1.45000E+01 0.00000E+00-9.60417E+00 0.00000E+00 1.23958E+00
111 0.00000E+00-3.71250E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.54687E+00
112 0.00000E+00-1.45375E+01 0.00000E+00-3.28125E+00 0.00000E+00-2.77604E+00
113 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.23958E+00
114 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.23958E+00
115 0.00000E+00-1.00125E+01 0.00000E+00-1.39583E+00 0.00000E+00 2.77604E+00
116 0.00000E+00-3.35000E+00 0.00000E+00-1.39583E+00 0.00000E+00 0.00000E+00
117 0.00000E+00-5.76250E+00 0.00000E+00-2.40104E+00 0.00000E+00 0.00000E+00
118 0.00000E+00-1.21875E+01 0.00000E+00-2.60417E+00 0.00000E+00 2.47396E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 4


LOADTYPE LIVE REDUCIBLE TITLE LL 3
STAAD SPACE -- PAGE NO. 23

CENTER OF FORCE BASED ON Y FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.925786787E+01
Y = 0.399999998E+01
Z = -0.111244553E+02

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 4 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -390.05
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -4339.09 MY= 0.00 MZ= -3611.03

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 4 )


SUMMATION FORCE-X = -0.00
SUMMATION FORCE-Y = 390.05
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 4339.09 MY= -0.00 MZ= 3611.03

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 4)


MAXIMUMS AT NODE
X = 2.64940E-02 91
Y = -8.51344E-02 109
Z = 3.98317E-02 95
RX= -5.51915E-04 109
RY= -4.79132E-05 89
RZ= -1.24580E-04 64

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 0.00 0.00 0.00 0.00 0.00 0.00
0.57 -9.80 0.01 -0.00 0.00 0.00 111000

30 0.00 0.00 0.00 0.00 0.00 0.00


-0.71 -6.43 0.14 0.00 0.00 0.00 111000

31 0.00 0.00 0.00 0.00 0.00 0.00


0.28 -5.90 0.20 0.00 0.00 0.00 111000

32 0.00 0.00 0.00 0.00 0.00 0.00


0.28 -15.74 0.12 0.00 0.00 -0.00 111000

33 0.00 0.00 0.00 0.00 0.00 0.00


-0.53 -5.97 0.01 0.00 0.00 -0.00 111000

34 0.00 0.00 0.00 0.00 0.00 0.00


0.04 -6.73 -0.26 -0.00 0.00 0.00 111000

35 0.00 0.00 0.00 0.00 0.00 0.00


-0.00 -10.69 -0.26 -0.00 0.00 -0.00 111000
STAAD SPACE -- PAGE NO. 24

36 0.00 0.00 0.00 0.00 0.00 0.00


-0.31 -14.88 0.43 0.00 -0.00 -0.00 111000

37 0.00 0.00 0.00 0.00 0.00 0.00


0.10 -7.56 0.44 -0.00 0.00 0.00 111000

38 0.00 0.00 0.00 0.00 0.00 0.00


0.00 -0.95 -0.10 0.00 -0.00 0.00 111000

39 0.00 0.00 0.00 0.00 0.00 0.00


-0.02 -3.44 -0.33 0.00 -0.00 -0.00 111000

40 0.00 0.00 0.00 0.00 0.00 0.00


0.09 -8.65 0.19 -0.00 -0.00 0.00 111000

41 0.00 0.00 0.00 0.00 0.00 0.00


-0.06 -7.77 0.39 -0.00 -0.00 0.00 111000

42 0.00 0.00 0.00 0.00 0.00 0.00


-0.18 -0.65 -0.07 -0.00 0.00 -0.00 111000

43 0.00 0.00 0.00 0.00 0.00 0.00


0.30 -16.23 -0.45 0.00 -0.00 -0.00 111000

44 0.00 0.00 0.00 0.00 0.00 0.00


-0.18 -10.31 -0.07 0.00 0.00 -0.00 111000

45 0.00 0.00 0.00 0.00 0.00 0.00


0.23 -24.08 0.28 0.00 0.00 0.00 111000

46 0.00 0.00 0.00 0.00 0.00 0.00


-0.06 -44.41 -2.60 -0.00 0.00 -0.00 111000

47 0.00 0.00 0.00 0.00 0.00 0.00


-0.06 -6.20 -0.04 -0.00 0.00 -0.00 111000

48 0.00 0.00 0.00 0.00 0.00 0.00


0.19 -18.84 0.28 -0.00 0.00 0.00 111000

49 0.00 0.00 0.00 0.00 0.00 0.00


-0.08 -3.18 -0.35 -0.00 -0.00 -0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


0.05 -0.69 -0.25 -0.00 -0.00 0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


-0.15 -24.40 -0.23 -0.00 0.00 0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


0.07 -20.33 -0.28 -0.00 0.00 0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


0.30 -27.16 0.13 0.00 0.00 -0.00 111000

54 0.00 0.00 0.00 0.00 0.00 0.00


0.29 -21.39 0.12 -0.00 -0.00 0.00 111000

55 0.00 0.00 0.00 0.00 0.00 0.00


-0.13 -54.08 2.56 0.00 0.00 -0.00 111000

56 0.00 0.00 0.00 0.00 0.00 0.00


-0.32 -13.58 -0.02 0.00 0.00 -0.00 111000

FOR LOADING - 5
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
STAAD SPACE -- PAGE NO. 25

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
67 0.00000E+00-1.00500E+01 0.00000E+00 4.18750E+00 0.00000E+00 0.00000E+00
69 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.23958E+00
70 0.00000E+00-8.92500E+00 0.00000E+00 0.00000E+00 0.00000E+00-3.71875E+00
71 0.00000E+00-5.95000E+00 0.00000E+00 0.00000E+00 0.00000E+00 4.95833E+00
73 0.00000E+00-9.96250E+00 0.00000E+00-2.60417E+00 0.00000E+00 1.54688E+00
74 0.00000E+00-3.71250E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.54688E+00
75 0.00000E+00-4.31750E+01 0.00000E+00-7.44792E+01 0.00000E+00-6.18750E+00
76 0.00000E+00-1.31875E+01 0.00000E+00-2.40104E+00 0.00000E+00 6.18750E+00
77 0.00000E+00-1.25000E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
78 0.00000E+00-1.15250E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
81 0.00000E+00-1.29125E+01 0.00000E+00-2.60417E+00 0.00000E+00 2.77604E+00
82 0.00000E+00-1.90875E+01 0.00000E+00-2.40104E+00 0.00000E+00 1.11042E+01
83 0.00000E+00-6.66250E+00 0.00000E+00 0.00000E+00 0.00000E+00-2.77604E+00
84 0.00000E+00-4.90750E+01 0.00000E+00 7.44792E+01 0.00000E+00-1.11042E+01
109 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00-1.23958E+00
110 0.00000E+00-2.97500E+00 0.00000E+00 0.00000E+00 0.00000E+00 1.23958E+00
111 0.00000E+00-1.94625E+01 0.00000E+00 1.31250E+01 0.00000E+00 1.54688E+00
112 0.00000E+00-6.66250E+00 0.00000E+00 0.00000E+00 0.00000E+00 2.77604E+00
113 0.00000E+00-9.22500E+00 0.00000E+00 2.60417E+00 0.00000E+00-1.23958E+00
114 0.00000E+00-8.73750E+00 0.00000E+00 2.40104E+00 0.00000E+00-1.23958E+00
115 0.00000E+00-3.35000E+00 0.00000E+00 1.39583E+00 0.00000E+00 0.00000E+00
116 0.00000E+00-1.00125E+01 0.00000E+00 1.39583E+00 0.00000E+00-2.77604E+00
117 0.00000E+00-1.17000E+01 0.00000E+00 2.40104E+00 0.00000E+00-2.47396E+00
118 0.00000E+00-6.25000E+00 0.00000E+00 2.60417E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 5


LOADTYPE LIVE REDUCIBLE TITLE LL 4

CENTER OF FORCE BASED ON Y FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.106201130E+02
Y = 0.399999998E+01
Z = -0.100636116E+02

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 5 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -396.45
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -3989.72 MY= 0.00 MZ= -4210.34

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 5 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 396.45
SUMMATION FORCE-Z = -0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 3989.72 MY= -0.00 MZ= 4210.34
STAAD SPACE -- PAGE NO. 26

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 5)


MAXIMUMS AT NODE
X = -2.46151E-02 92
Y = -1.04683E-01 111
Z = -5.57763E-02 59
RX= 6.93229E-04 111
RY= -5.29518E-05 75
RZ= -1.31771E-04 118

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 0.00 0.00 0.00 0.00 0.00 0.00
0.06 -7.43 -0.37 -0.00 -0.00 -0.00 111000

30 0.00 0.00 0.00 0.00 0.00 0.00


0.07 -10.70 0.11 0.00 -0.00 0.00 111000

31 0.00 0.00 0.00 0.00 0.00 0.00


-0.01 -29.78 1.05 -0.00 0.00 -0.00 111000

32 0.00 0.00 0.00 0.00 0.00 0.00


-0.07 -10.71 0.11 0.00 0.00 -0.00 111000

33 0.00 0.00 0.00 0.00 0.00 0.00


-0.06 -7.40 -0.38 0.00 0.00 -0.00 111000

34 0.00 0.00 0.00 0.00 0.00 0.00


0.01 -10.35 0.41 -0.00 -0.00 0.00 111000

35 0.00 0.00 0.00 0.00 0.00 0.00


0.00 -6.54 0.40 -0.00 0.00 0.00 111000

36 0.00 0.00 0.00 0.00 0.00 0.00


-0.12 -7.54 -0.39 0.00 -0.00 0.00 111000

37 0.00 0.00 0.00 0.00 0.00 0.00


0.32 -14.75 -0.42 0.00 -0.00 -0.00 111000

38 0.00 0.00 0.00 0.00 0.00 0.00


-0.00 -14.24 -0.09 -0.00 -0.00 0.00 111000

39 0.00 0.00 0.00 0.00 0.00 0.00


0.02 -11.74 0.12 -0.00 0.00 -0.00 111000

40 0.00 0.00 0.00 0.00 0.00 0.00


0.25 -6.73 0.22 -0.00 0.00 -0.00 111000

41 0.00 0.00 0.00 0.00 0.00 0.00


-0.27 -7.49 0.01 0.00 0.00 -0.00 111000

42 0.00 0.00 0.00 0.00 0.00 0.00


-0.02 -12.91 -0.00 0.00 0.00 0.00 111000

43 0.00 0.00 0.00 0.00 0.00 0.00


-0.30 -7.23 -0.40 0.00 -0.00 0.00 111000

44 0.00 0.00 0.00 0.00 0.00 0.00


0.36 -3.09 -0.01 -0.00 0.00 0.00 111000
STAAD SPACE -- PAGE NO. 27

49 0.00 0.00 0.00 0.00 0.00 0.00


-0.08 -16.75 -0.11 -0.00 0.00 0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


0.10 -17.89 -0.18 0.00 0.00 -0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


-0.07 -2.10 0.15 0.00 -0.00 0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


0.14 -4.27 0.21 -0.00 0.00 0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


-0.26 -18.17 -0.17 -0.00 0.00 0.00 111000

54 0.00 0.00 0.00 0.00 0.00 0.00


-0.32 -22.33 -0.15 0.00 -0.00 0.00 111000

55 0.00 0.00 0.00 0.00 0.00 0.00


0.25 -10.31 -0.07 -0.00 -0.00 0.00 111000

56 0.00 0.00 0.00 0.00 0.00 0.00


0.21 -50.81 2.51 0.00 0.00 0.00 111000

FOR LOADING - 6
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
85-5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
88 5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
89-5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
90 5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
91-5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
92 5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
93-5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
94 5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
121-5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
122 5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
123-5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
124 5.83670E+01-3.71210E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 6


LOADTYPE ROOF LIVE TITLE RLL

CENTER OF FORCE BASED ON Y FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.999999996E+01
Y = 0.699999978E+01
Z = -0.112500001E+02

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 6 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = -445.45
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -5011.34 MY= -0.00 MZ= -4454.52
STAAD SPACE -- PAGE NO. 28

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 6 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 445.45
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 5011.34 MY= -0.00 MZ= 4454.52

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 6)


MAXIMUMS AT NODE
X = 7.98195E+00 92
Y = 2.33414E-01 120
Z = -2.31871E-01 71
RX= -4.44394E-04 43
RY= 2.07538E-02 124
RZ= -1.14218E-02 92

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 0.00 0.00 0.00 0.00 0.00 0.00
0.13 -1.79 1.30 0.00 0.00 0.00 111000

30 0.00 0.00 0.00 0.00 0.00 0.00


0.05 0.12 -0.18 0.00 0.00 0.00 111000

31 0.00 0.00 0.00 0.00 0.00 0.00


0.00 -0.01 1.63 -0.00 -0.00 0.00 111000

32 0.00 0.00 0.00 0.00 0.00 0.00


-0.05 0.12 -0.18 -0.00 0.00 0.00 111000

33 0.00 0.00 0.00 0.00 0.00 0.00


-0.13 -1.79 1.30 0.00 0.00 0.00 111000

34 0.00 0.00 0.00 0.00 0.00 0.00


1.83 -4.13 1.75 0.00 -0.00 -0.00 111000

35 0.00 0.00 0.00 0.00 0.00 0.00


-1.83 -4.13 1.75 0.00 -0.00 -0.00 111000

36 0.00 0.00 0.00 0.00 0.00 0.00


-23.07 -80.26 1.53 0.00 0.00 0.00 111000

37 0.00 0.00 0.00 0.00 0.00 0.00


23.07 -80.26 1.53 0.00 0.00 -0.00 111000

38 0.00 0.00 0.00 0.00 0.00 0.00


-3.77 -2.12 1.55 -0.00 0.00 0.00 111000

39 0.00 0.00 0.00 0.00 0.00 0.00


3.77 -2.12 1.55 -0.00 0.00 -0.00 111000

40 0.00 0.00 0.00 0.00 0.00 0.00


-0.02 -1.47 1.05 -0.00 -0.00 0.00 111000

41 0.00 0.00 0.00 0.00 0.00 0.00


0.02 -1.47 1.05 0.00 0.00 0.00 111000
STAAD SPACE -- PAGE NO. 29

44 0.00 0.00 0.00 0.00 0.00 0.00


-0.02 -0.85 -0.71 0.00 -0.00 0.00 111000

45 0.00 0.00 0.00 0.00 0.00 0.00


1.84 -30.66 -1.51 -0.00 0.00 -0.00 111000

46 0.00 0.00 0.00 0.00 0.00 0.00


0.25 1.35 -0.54 0.00 -0.00 0.00 111000

47 0.00 0.00 0.00 0.00 0.00 0.00


-0.25 1.35 -0.54 -0.00 -0.00 -0.00 111000

48 0.00 0.00 0.00 0.00 0.00 0.00


-1.84 -30.66 -1.51 -0.00 -0.00 -0.00 111000

49 0.00 0.00 0.00 0.00 0.00 0.00


0.87 -17.83 -4.40 -0.00 0.00 0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


-0.87 -17.83 -4.40 0.00 0.00 -0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


19.39 -33.84 2.40 0.00 -0.00 0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


-19.39 -33.84 2.40 -0.00 0.00 0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


1.43 -52.10 -1.18 -0.00 -0.00 0.00 111000

54 0.00 0.00 0.00 0.00 0.00 0.00


-1.43 -52.10 -1.18 -0.00 -0.00 -0.00 111000

55 0.00 0.00 0.00 0.00 0.00 0.00


0.32 2.60 -0.49 0.00 0.00 -0.00 111000

56 0.00 0.00 0.00 0.00 0.00 0.00


-0.32 2.60 -0.49 0.00 0.00 -0.00 111000

FOR LOADING - 7
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
1 2.04929E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
6 4.09858E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
8 4.09858E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
10 3.58626E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
12 1.53697E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
29 8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
34 1.75653E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
36 1.75653E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
38 1.75653E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
40 8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
57 1.17102E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
62 2.34204E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
64 2.34204E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
66 2.04929E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
68 8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
73 4.45226E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
77 1.11453E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
79 1.55976E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
81 8.90452E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
85 4.61782E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
89 1.15311E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
91 1.38265E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
93 6.91323E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
103 1.02464E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
STAAD SPACE -- PAGE NO. 30

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
121 9.44568E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
123 9.44568E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 7


LOADTYPE WIND TITLE WL +X

CENTER OF FORCE BASED ON X FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.499377580E+00
Y = 0.148305448E+01
Z = -0.102315543E+02

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 7 )


SUMMATION FORCE-X = 409.73
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.00 MY= -4192.18 MZ= -607.65

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 7 )


SUMMATION FORCE-X = -409.73
SUMMATION FORCE-Y = -0.00
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.00 MY= 4192.18 MZ= 607.65

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 7)


MAXIMUMS AT NODE
X = 4.23721E+00 91
Y = -2.08899E-01 120
Z = 9.50553E-02 86
RX= 1.31566E-04 43
RY= 6.97666E-03 123
RZ= -6.15502E-03 36

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 8.78 0.00 0.00 0.00 0.00 0.00
8.19 13.25 -0.88 -0.00 0.00 -0.00 111000

30 0.00 0.00 0.00 0.00 0.00 0.00


10.09 -1.97 -0.00 -0.00 -0.00 -0.00 111000

31 0.00 0.00 0.00 0.00 0.00 0.00


10.09 -0.28 -0.13 0.00 0.00 -0.00 111000
STAAD SPACE -- PAGE NO. 31

32 0.00 0.00 0.00 0.00 0.00 0.00


9.69 1.93 0.21 0.00 -0.00 0.00 111000

33 0.00 0.00 0.00 0.00 0.00 0.00


7.46 -12.36 -0.15 -0.00 0.00 -0.00 111000

34 17.57 0.00 0.00 0.00 0.00 0.00


15.75 64.71 -1.08 -0.00 0.00 0.00 111000

35 0.00 0.00 0.00 0.00 0.00 0.00


14.90 -63.18 -0.24 0.00 -0.00 -0.00 111000

36 17.57 0.00 0.00 0.00 0.00 0.00


36.07 60.44 -0.93 -0.00 -0.00 0.00 111000

37 0.00 0.00 0.00 0.00 0.00 0.00


4.99 -21.48 -0.28 -0.00 0.00 -0.00 111000

38 17.57 0.00 0.00 0.00 0.00 0.00


18.04 12.83 -1.96 0.00 0.00 0.00 111000

39 0.00 0.00 0.00 0.00 0.00 0.00


2.33 -10.89 0.64 -0.00 0.00 -0.00 111000

40 8.78 0.00 0.00 0.00 0.00 0.00


10.18 28.66 0.56 -0.00 -0.00 0.00 111000

41 0.00 0.00 0.00 0.00 0.00 0.00


9.63 -27.38 -1.25 -0.00 0.00 -0.00 111000

42 0.00 0.00 0.00 0.00 0.00 0.00


12.03 -3.26 0.44 0.00 0.00 -0.00 111000

43 0.00 0.00 0.00 0.00 0.00 0.00


12.36 1.31 0.69 -0.00 0.00 -0.00 111000

44 0.00 0.00 0.00 0.00 0.00 0.00


11.72 3.47 -0.13 -0.00 0.00 0.00 111000

45 0.00 0.00 0.00 0.00 0.00 0.00


18.71 -41.77 0.80 0.00 0.00 0.00 111000

46 0.00 0.00 0.00 0.00 0.00 0.00


15.65 1.17 0.38 -0.00 0.00 0.00 111000

47 0.00 0.00 0.00 0.00 0.00 0.00


15.38 -1.22 0.18 0.00 -0.00 -0.00 111000

48 0.00 0.00 0.00 0.00 0.00 0.00


18.61 39.62 0.13 -0.00 0.00 0.00 111000

49 0.00 0.00 0.00 0.00 0.00 0.00


12.60 -31.21 3.88 0.00 -0.00 0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


3.64 12.07 -0.83 -0.00 -0.00 0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


7.05 -30.87 -2.50 0.00 0.00 0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


2.10 10.88 1.11 -0.00 0.00 0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


12.84 -3.94 0.68 0.00 -0.00 0.00 111000
STAAD SPACE -- PAGE NO. 32

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
9-4.09858E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
11-3.58626E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
13-1.53697E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
33-8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
35-1.75653E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
37-1.75653E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
39-1.75653E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
41-8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
61-1.17102E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
63-2.34204E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
65-2.34204E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
67-2.04929E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
69-8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
76-4.45226E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
78-1.11453E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
80-1.55976E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
82-8.90452E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
88-4.61782E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
90-1.15311E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
92-1.38265E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
94-6.91323E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
102-1.02464E+01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
115-5.85511E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
117-2.96668E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
122-9.44568E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00
124-9.44568E-01 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 8


LOADTYPE WIND TITLE WL -X

CENTER OF FORCE BASED ON X FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.195006230E+02
Y = 0.148305448E+01
Z = -0.102315543E+02

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 8 )


SUMMATION FORCE-X = -409.73
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 0.00

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.00 MY= 4192.18 MZ= 607.65

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 8 )


SUMMATION FORCE-X = 409.73
SUMMATION FORCE-Y = -0.00
SUMMATION FORCE-Z = -0.00
STAAD SPACE -- PAGE NO. 33

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 0.00 MY= -4192.18 MZ= -607.65

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 8)


MAXIMUMS AT NODE
X = -4.23721E+00 92
Y = -2.08899E-01 119
Z = 9.50554E-02 87
RX= 1.31566E-04 43
RY= -6.97666E-03 124
RZ= 6.15502E-03 37

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 0.00 0.00 0.00 0.00 0.00 0.00
-7.46 -12.36 -0.15 -0.00 0.00 -0.00 111000

30 0.00 0.00 0.00 0.00 0.00 0.00


-9.69 1.93 0.21 0.00 0.00 -0.00 111000

31 0.00 0.00 0.00 0.00 0.00 0.00


-10.09 -0.28 -0.13 0.00 -0.00 0.00 111000

32 0.00 0.00 0.00 0.00 0.00 0.00


-10.09 -1.97 -0.00 0.00 -0.00 0.00 111000

33 -8.78 0.00 0.00 0.00 0.00 0.00


-8.19 13.25 -0.88 -0.00 -0.00 -0.00 111000

34 0.00 0.00 0.00 0.00 0.00 0.00


-14.90 -63.18 -0.24 -0.00 -0.00 -0.00 111000

35 -17.57 0.00 0.00 0.00 0.00 0.00


-15.75 64.71 -1.08 -0.00 0.00 0.00 111000

36 0.00 0.00 0.00 0.00 0.00 0.00


-4.99 -21.48 -0.28 0.00 0.00 -0.00 111000

37 -17.57 0.00 0.00 0.00 0.00 0.00


-36.07 60.44 -0.93 -0.00 0.00 -0.00 111000

38 0.00 0.00 0.00 0.00 0.00 0.00


-2.33 -10.89 0.64 0.00 0.00 -0.00 111000

39 -17.57 0.00 0.00 0.00 0.00 0.00


-18.04 12.83 -1.96 0.00 0.00 0.00 111000

40 0.00 0.00 0.00 0.00 0.00 0.00


-9.63 -27.38 -1.25 0.00 0.00 0.00 111000

41 -8.78 0.00 0.00 0.00 0.00 0.00


-10.18 28.66 0.56 0.00 -0.00 -0.00 111000

42 0.00 0.00 0.00 0.00 0.00 0.00


-11.72 3.47 -0.13 -0.00 -0.00 -0.00 111000

43 0.00 0.00 0.00 0.00 0.00 0.00


-12.36 1.31 0.69 -0.00 0.00 0.00 111000
STAAD SPACE -- PAGE NO. 34

47 0.00 0.00 0.00 0.00 0.00 0.00


-15.65 1.17 0.38 0.00 -0.00 -0.00 111000

48 0.00 0.00 0.00 0.00 0.00 0.00


-18.71 -41.77 0.80 0.00 0.00 -0.00 111000

49 0.00 0.00 0.00 0.00 0.00 0.00


-3.64 12.07 -0.83 0.00 -0.00 0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


-12.60 -31.21 3.88 -0.00 -0.00 -0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


-2.10 10.88 1.11 0.00 0.00 -0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


-7.05 -30.87 -2.50 -0.00 -0.00 0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


-13.50 0.42 0.10 0.00 0.00 -0.00 111000

54 0.00 0.00 0.00 0.00 0.00 0.00


-12.84 -3.94 0.68 -0.00 -0.00 0.00 111000

55 0.00 0.00 0.00 0.00 0.00 0.00


-13.03 -3.09 0.22 -0.00 0.00 0.00 111000

56 0.00 0.00 0.00 0.00 0.00 0.00


-12.84 2.17 0.33 -0.00 0.00 0.00 111000

FOR LOADING - 9
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
12 0.00000E+00 0.00000E+00 1.53697E+01 0.00000E+00 0.00000E+00 0.00000E+00
13 0.00000E+00 0.00000E+00 1.53697E+01 0.00000E+00 0.00000E+00 0.00000E+00
14 0.00000E+00 0.00000E+00 3.58626E+01 0.00000E+00 0.00000E+00 0.00000E+00
15 0.00000E+00 0.00000E+00 4.09858E+01 0.00000E+00 0.00000E+00 0.00000E+00
16 0.00000E+00 0.00000E+00 3.58626E+01 0.00000E+00 0.00000E+00 0.00000E+00
40 0.00000E+00 0.00000E+00 8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00
41 0.00000E+00 0.00000E+00 8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00
42 0.00000E+00 0.00000E+00 1.75653E+01 0.00000E+00 0.00000E+00 0.00000E+00
43 0.00000E+00 0.00000E+00 1.75653E+01 0.00000E+00 0.00000E+00 0.00000E+00
44 0.00000E+00 0.00000E+00 1.75653E+01 0.00000E+00 0.00000E+00 0.00000E+00
68 0.00000E+00 0.00000E+00 8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00
69 0.00000E+00 0.00000E+00 8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00
70 0.00000E+00 0.00000E+00 2.04929E+01 0.00000E+00 0.00000E+00 0.00000E+00
71 0.00000E+00 0.00000E+00 2.34204E+01 0.00000E+00 0.00000E+00 0.00000E+00
72 0.00000E+00 0.00000E+00 2.04929E+01 0.00000E+00 0.00000E+00 0.00000E+00
81 0.00000E+00 0.00000E+00 8.90452E+00 0.00000E+00 0.00000E+00 0.00000E+00
82 0.00000E+00 0.00000E+00 8.90452E+00 0.00000E+00 0.00000E+00 0.00000E+00
83 0.00000E+00 0.00000E+00 1.55976E+01 0.00000E+00 0.00000E+00 0.00000E+00
84 0.00000E+00 0.00000E+00 1.55976E+01 0.00000E+00 0.00000E+00 0.00000E+00
93 0.00000E+00 0.00000E+00 9.23565E+00 0.00000E+00 0.00000E+00 0.00000E+00
94 0.00000E+00 0.00000E+00 9.23565E+00 0.00000E+00 0.00000E+00 0.00000E+00
95 0.00000E+00 0.00000E+00 1.84713E+01 0.00000E+00 0.00000E+00 0.00000E+00
96 0.00000E+00 0.00000E+00 1.84713E+01 0.00000E+00 0.00000E+00 0.00000E+00
106 0.00000E+00 0.00000E+00 1.02464E+01 0.00000E+00 0.00000E+00 0.00000E+00
107 0.00000E+00 0.00000E+00 1.02464E+01 0.00000E+00 0.00000E+00 0.00000E+00
112 0.00000E+00 0.00000E+00 2.96668E+00 0.00000E+00 0.00000E+00 0.00000E+00
113 0.00000E+00 0.00000E+00 5.85511E+00 0.00000E+00 0.00000E+00 0.00000E+00
114 0.00000E+00 0.00000E+00 5.85511E+00 0.00000E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 9


LOADTYPE WIND TITLE WL +Z
STAAD SPACE -- PAGE NO. 35

CENTER OF FORCE BASED ON Z FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.100000002E+02
Y = 0.174540403E+01
Z = -0.193832309E+02

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 9 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 435.27

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 759.72 MY= -4352.71 MZ= 0.00

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 9 )


SUMMATION FORCE-X = -0.00
SUMMATION FORCE-Y = -0.00
SUMMATION FORCE-Z = -435.27

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -759.72 MY= 4352.71 MZ= 0.00

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 9)


MAXIMUMS AT NODE
X = -1.89918E-01 90
Y = -1.89329E-01 108
Z = 3.27630E+00 96
RX= 5.60270E-03 43
RY= -3.79260E-03 70
RZ= 2.14127E-04 90

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 0.00 0.00 0.00 0.00 0.00 0.00
-0.46 -18.21 9.40 0.00 0.00 -0.00 111000

30 0.00 0.00 0.00 0.00 0.00 0.00


0.36 -4.64 3.78 0.00 0.00 0.00 111000

31 0.00 0.00 0.00 0.00 0.00 0.00


0.00 -18.74 13.16 0.00 0.00 0.00 111000

32 0.00 0.00 0.00 0.00 0.00 0.00


-0.36 -4.64 3.78 0.00 0.00 -0.00 111000

33 0.00 0.00 0.00 0.00 0.00 0.00


0.46 -18.21 9.40 0.00 0.00 -0.00 111000

34 0.00 0.00 0.00 0.00 0.00 0.00


-0.08 -0.22 11.41 0.00 0.00 -0.00 111000

35 0.00 0.00 0.00 0.00 0.00 0.00


0.08 -0.22 11.41 0.00 -0.00 0.00 111000
STAAD SPACE -- PAGE NO. 36

36 0.00 0.00 0.00 0.00 0.00 0.00


1.16 1.98 12.40 -0.00 -0.00 0.00 111000

37 0.00 0.00 0.00 0.00 0.00 0.00


-1.16 1.98 12.40 -0.00 0.00 0.00 111000

38 0.00 0.00 0.00 0.00 0.00 0.00


0.34 -3.49 12.09 0.00 0.00 -0.00 111000

39 0.00 0.00 0.00 0.00 0.00 0.00


-0.34 -3.49 12.09 -0.00 -0.00 0.00 111000

40 0.00 0.00 8.78 0.00 0.00 0.00


1.33 29.61 10.20 0.00 -0.00 0.00 111000

41 0.00 0.00 8.78 0.00 0.00 0.00


-1.33 29.61 10.20 0.00 -0.00 0.00 111000

42 0.00 0.00 17.57 0.00 0.00 0.00


-1.12 13.00 17.21 0.00 0.00 -0.00 111000

43 0.00 0.00 17.57 0.00 0.00 0.00


-0.00 54.68 32.40 -0.00 -0.00 -0.00 111000

44 0.00 0.00 17.57 0.00 0.00 0.00


1.12 13.00 17.21 0.00 -0.00 -0.00 111000

45 0.00 0.00 0.00 0.00 0.00 0.00


-0.18 -67.71 15.35 0.00 -0.00 -0.00 111000

46 0.00 0.00 0.00 0.00 0.00 0.00


0.87 1.10 11.29 0.00 0.00 0.00 111000

47 0.00 0.00 0.00 0.00 0.00 0.00


-0.87 1.10 11.29 0.00 0.00 -0.00 111000

48 0.00 0.00 0.00 0.00 0.00 0.00


0.18 -67.71 15.35 -0.00 0.00 0.00 111000

49 0.00 0.00 0.00 0.00 0.00 0.00


0.53 52.81 17.21 -0.00 0.00 0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


-0.53 52.81 17.21 -0.00 0.00 -0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


0.54 1.42 13.91 -0.00 -0.00 0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


-0.54 1.42 13.91 0.00 -0.00 0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


-0.01 -3.86 14.26 0.00 -0.00 -0.00 111000

54 0.00 0.00 0.00 0.00 0.00 0.00


0.01 -3.86 14.26 -0.00 -0.00 0.00 111000

55 0.00 0.00 0.00 0.00 0.00 0.00


-2.88 -19.74 11.22 -0.00 -0.00 -0.00 111000

56 0.00 0.00 0.00 0.00 0.00 0.00


2.88 -19.74 11.22 0.00 0.00 0.00 111000

FOR LOADING - 10
APPLIED JOINT EQUIVALENT LOADS
JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
STAAD SPACE -- PAGE NO. 37

APPLIED JOINT EQUIVALENT LOADS


JOINT FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM-Z
57 0.00000E+00 0.00000E+00-8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00
58 0.00000E+00 0.00000E+00-2.04929E+01 0.00000E+00 0.00000E+00 0.00000E+00
59 0.00000E+00 0.00000E+00-2.34204E+01 0.00000E+00 0.00000E+00 0.00000E+00
60 0.00000E+00 0.00000E+00-2.04929E+01 0.00000E+00 0.00000E+00 0.00000E+00
61 0.00000E+00 0.00000E+00-8.78267E+00 0.00000E+00 0.00000E+00 0.00000E+00
73 0.00000E+00 0.00000E+00-8.90452E+00 0.00000E+00 0.00000E+00 0.00000E+00
74 0.00000E+00 0.00000E+00-1.55976E+01 0.00000E+00 0.00000E+00 0.00000E+00
75 0.00000E+00 0.00000E+00-1.55976E+01 0.00000E+00 0.00000E+00 0.00000E+00
76 0.00000E+00 0.00000E+00-8.90452E+00 0.00000E+00 0.00000E+00 0.00000E+00
85 0.00000E+00 0.00000E+00-9.23565E+00 0.00000E+00 0.00000E+00 0.00000E+00
86 0.00000E+00 0.00000E+00-1.84713E+01 0.00000E+00 0.00000E+00 0.00000E+00
87 0.00000E+00 0.00000E+00-1.84713E+01 0.00000E+00 0.00000E+00 0.00000E+00
88 0.00000E+00 0.00000E+00-9.23565E+00 0.00000E+00 0.00000E+00 0.00000E+00
97 0.00000E+00 0.00000E+00-1.02464E+01 0.00000E+00 0.00000E+00 0.00000E+00
98 0.00000E+00 0.00000E+00-1.02464E+01 0.00000E+00 0.00000E+00 0.00000E+00
109 0.00000E+00 0.00000E+00-5.85511E+00 0.00000E+00 0.00000E+00 0.00000E+00
110 0.00000E+00 0.00000E+00-5.85511E+00 0.00000E+00 0.00000E+00 0.00000E+00
111 0.00000E+00 0.00000E+00-2.96668E+00 0.00000E+00 0.00000E+00 0.00000E+00

STATIC LOAD/REACTION/EQUILIBRIUM SUMMARY FOR CASE NO. 10


LOADTYPE WIND TITLE WL -Z

CENTER OF FORCE BASED ON Z FORCES ONLY (METE).


(FORCES IN NON-GLOBAL DIRECTIONS WILL INVALIDATE RESULTS)

X = 0.100000002E+02
Y = 0.174540403E+01
Z = -0.123353913E+01

***TOTAL APPLIED LOAD ( KN METE ) SUMMARY (LOADING 10 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = -435.27

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= -759.72 MY= 4352.71 MZ= 0.00

***TOTAL REACTION LOAD( KN METE ) SUMMARY (LOADING 10 )


SUMMATION FORCE-X = 0.00
SUMMATION FORCE-Y = 0.00
SUMMATION FORCE-Z = 435.27

SUMMATION OF MOMENTS AROUND THE ORIGIN-


MX= 759.72 MY= -4352.71 MZ= -0.00
STAAD SPACE -- PAGE NO. 38

MAXIMUM DISPLACEMENTS ( CM /RADIANS) (LOADING 10)


MAXIMUMS AT NODE
X = 1.42736E-01 90
Y = 1.59372E-01 108
Z = -3.30488E+00 87
RX= -5.61964E-03 31
RY= 3.88918E-03 58
RZ= -1.81530E-04 90

EXTERNAL AND INTERNAL JOINT LOAD SUMMARY ( KN METE )-

JT EXT FX/ EXT FY/ EXT FZ/ EXT MX/ EXT MY/ EXT MZ/
INT FX INT FY INT FZ INT MX INT MY INT MZ

SUPPORT=1
29 0.00 0.00 -8.78 0.00 0.00 0.00
0.52 18.67 -9.86 -0.00 -0.00 -0.00 111000

30 0.00 0.00 -17.57 0.00 0.00 0.00


-0.43 5.18 -17.17 -0.00 0.00 -0.00 111000

31 0.00 0.00 -17.57 0.00 0.00 0.00


-0.00 21.31 -28.38 -0.00 0.00 0.00 111000

32 0.00 0.00 -17.57 0.00 0.00 0.00


0.43 5.18 -17.17 0.00 -0.00 -0.00 111000

33 0.00 0.00 -8.78 0.00 0.00 0.00


-0.52 18.67 -9.86 -0.00 0.00 -0.00 111000

34 0.00 0.00 0.00 0.00 0.00 0.00


0.05 0.23 -11.67 0.00 0.00 -0.00 111000

35 0.00 0.00 0.00 0.00 0.00 0.00


-0.05 0.23 -11.67 -0.00 0.00 -0.00 111000

36 0.00 0.00 0.00 0.00 0.00 0.00


-1.03 -1.29 -12.35 0.00 0.00 0.00 111000

37 0.00 0.00 0.00 0.00 0.00 0.00


1.03 -1.29 -12.35 -0.00 0.00 -0.00 111000

38 0.00 0.00 0.00 0.00 0.00 0.00


-0.44 3.48 -11.72 0.00 -0.00 0.00 111000

39 0.00 0.00 0.00 0.00 0.00 0.00


0.44 3.48 -11.72 0.00 0.00 0.00 111000

40 0.00 0.00 0.00 0.00 0.00 0.00


-1.20 -28.58 -9.62 -0.00 -0.00 0.00 111000

41 0.00 0.00 0.00 0.00 0.00 0.00


1.20 -28.58 -9.62 0.00 -0.00 -0.00 111000

42 0.00 0.00 0.00 0.00 0.00 0.00


0.98 -12.00 -3.98 0.00 -0.00 0.00 111000

43 0.00 0.00 0.00 0.00 0.00 0.00


0.00 -48.46 -16.75 -0.00 0.00 -0.00 111000

44 0.00 0.00 0.00 0.00 0.00 0.00


-0.98 -12.00 -3.98 -0.00 -0.00 0.00 111000
STAAD SPACE -- PAGE NO. 39

49 0.00 0.00 0.00 0.00 0.00 0.00


-0.10 -52.97 -17.22 0.00 -0.00 0.00 111000

50 0.00 0.00 0.00 0.00 0.00 0.00


0.10 -52.97 -17.22 0.00 -0.00 0.00 111000

51 0.00 0.00 0.00 0.00 0.00 0.00


-0.39 -1.60 -13.91 -0.00 0.00 0.00 111000

52 0.00 0.00 0.00 0.00 0.00 0.00


0.39 -1.60 -13.91 0.00 0.00 0.00 111000

53 0.00 0.00 0.00 0.00 0.00 0.00


0.03 1.78 -14.09 -0.00 -0.00 0.00 111000

54 0.00 0.00 0.00 0.00 0.00 0.00


-0.03 1.78 -14.09 0.00 0.00 0.00 111000

55 0.00 0.00 0.00 0.00 0.00 0.00


2.38 16.47 -11.49 -0.00 -0.00 -0.00 111000

56 0.00 0.00 0.00 0.00 0.00 0.00


-2.38 16.47 -11.49 -0.00 -0.00 -0.00 111000

************ END OF DATA FROM INTERNAL STORAGE ************

202. START CONCRETE DESIGN


203. CODE ACI
204. FC 27600 ALL
205. FYMAIN 415000 ALL
206. DESIGN BEAM 1 TO 8 11 TO 30 87 TO 114 127 TO 144 147 TO 150 155 TO 198
STAAD SPACE -- PAGE NO. 40

ACI 318-11 BEAM NO. 1 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 4 - 12MM 0. 2500. YES YES


2 241. 4 - 16MM 0. 2500. YES YES

B E A M N O. 1 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 51.63 KNS Vc= 50.25 KNS Vs= 18.59 KNS
Tu= 4.37 KN-MET Tc= 1.6 KN-MET Ts= 5.8 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.80 SQ.CM.

AT END SUPPORT - Vu= 20.18 KNS Vc= 50.25 KNS Vs= 0.00 KNS
Tu= 4.37 KN-MET Tc= 1.6 KN-MET Ts= 5.8 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.80 SQ.CM.

___ 1J____________________ 2500X 250X 300_____________________ 97J____


| |
||=========================================================================||
| 4No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 4No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#16 | | 4#16 | | 4#16 | | 4#16 | | 4#16 |
| | | | | | | | | |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| oooo | | oooo | | oooo | | oooo | | oooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 41

ACI 318-11 BEAM NO. 2 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 2 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 35.28 KNS Vc= 51.72 KNS Vs= 0.00 KNS
Tu= 0.16 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 34.97 KNS Vc= 51.72 KNS Vs= 0.00 KNS
Tu= 0.16 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 2J____________________ 5000X 250X 300_____________________ 3J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 42

ACI 318-11 BEAM NO. 3 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 3 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 34.96 KNS Vc= 51.72 KNS Vs= 0.00 KNS
Tu= 0.16 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 35.29 KNS Vc= 51.72 KNS Vs= 0.00 KNS
Tu= 0.16 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 3J____________________ 5000X 250X 300_____________________ 4J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 43

ACI 318-11 BEAM NO. 4 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 4 - 12MM 0. 2500. YES YES


2 241. 4 - 16MM 0. 2500. YES YES

B E A M N O. 4 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 50.85 KNS Vc= 50.34 KNS Vs= 17.45 KNS
Tu= 4.07 KN-MET Tc= 1.6 KN-MET Ts= 5.4 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.68 SQ.CM.

AT END SUPPORT - Vu= 19.39 KNS Vc= 50.34 KNS Vs= 0.00 KNS
Tu= 4.07 KN-MET Tc= 1.6 KN-MET Ts= 5.4 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.68 SQ.CM.

___ 4J____________________ 2499X 250X 300_____________________ 98J____


| |
||=========================================================================||
| 4No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 4No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#16 | | 4#16 | | 4#16 | | 4#16 | | 4#16 |
| | | | | | | | | |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| oooo | | oooo | | oooo | | oooo | | oooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 44

ACI 318-11 BEAM NO. 5 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 5 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 34.93 KNS Vc= 51.34 KNS Vs= 0.00 KNS
Tu= 0.18 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 35.33 KNS Vc= 51.34 KNS Vs= 0.00 KNS
Tu= 0.18 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 1J____________________ 5000X 250X 300_____________________ 6J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 45

ACI 318-11 BEAM NO. 6 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 6 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 34.92 KNS Vc= 51.36 KNS Vs= 0.00 KNS
Tu= 0.18 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 35.34 KNS Vc= 51.36 KNS Vs= 0.00 KNS
Tu= 0.18 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 5J____________________ 5000X 250X 300_____________________ 7J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 46

ACI 318-11 BEAM NO. 7 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 7 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 1.12 KNS Vc= 50.71 KNS Vs= 0.00 KNS
Tu= 7.66 KN-MET Tc= 1.6 KN-MET Ts= 10.2 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.16 SQ.CM.

AT END SUPPORT - Vu= 1.12 KNS Vc= 50.71 KNS Vs= 0.00 KNS
Tu= 7.66 KN-MET Tc= 1.6 KN-MET Ts= 10.2 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.16 SQ.CM.

___ 6J____________________ 5000X 250X 300_____________________ 8J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 47

ACI 318-11 BEAM NO. 8 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 8 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 1.12 KNS Vc= 50.71 KNS Vs= 0.00 KNS
Tu= 7.66 KN-MET Tc= 1.6 KN-MET Ts= 10.2 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.16 SQ.CM.

AT END SUPPORT - Vu= 1.12 KNS Vc= 50.71 KNS Vs= 0.00 KNS
Tu= 7.66 KN-MET Tc= 1.6 KN-MET Ts= 10.2 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.16 SQ.CM.

___ 7J____________________ 5000X 250X 300_____________________ 9J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 48

ACI 318-11 BEAM NO. 11 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 11 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 1.93 KNS Vc= 49.41 KNS Vs= 0.00 KNS
Tu= 3.83 KN-MET Tc= 1.6 KN-MET Ts= 5.1 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.58 SQ.CM.

AT END SUPPORT - Vu= 1.93 KNS Vc= 49.41 KNS Vs= 0.00 KNS
Tu= 3.83 KN-MET Tc= 1.6 KN-MET Ts= 5.1 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.58 SQ.CM.

___ 10J____________________ 2499X 250X 300_____________________ 103J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 49

ACI 318-11 BEAM NO. 12 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 12 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 1.93 KNS Vc= 49.41 KNS Vs= 0.00 KNS
Tu= 3.83 KN-MET Tc= 1.6 KN-MET Ts= 5.1 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.58 SQ.CM.

AT END SUPPORT - Vu= 1.93 KNS Vc= 49.41 KNS Vs= 0.00 KNS
Tu= 3.83 KN-MET Tc= 1.6 KN-MET Ts= 5.1 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.58 SQ.CM.

___ 11J____________________ 2499X 250X 300_____________________ 102J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 50

ACI 318-11 BEAM NO. 13 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 13 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 38.24 KNS Vc= 51.49 KNS Vs= 0.00 KNS
Tu= 2.61 KN-MET Tc= 1.6 KN-MET Ts= 3.5 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.08 SQ.CM.

AT END SUPPORT - Vu= 6.79 KNS Vc= 51.49 KNS Vs= 0.00 KNS
Tu= 2.61 KN-MET Tc= 1.6 KN-MET Ts= 3.5 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.08 SQ.CM.

___ 12J____________________ 2500X 250X 300_____________________ 106J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 51

ACI 318-11 BEAM NO. 14 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 4056. YES NO


2 57. 2 - 12MM 4375. 5000. NO YES
3 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 14 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 35.16 KNS Vc= 51.95 KNS Vs= 0.00 KNS
Tu= 0.18 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 35.08 KNS Vc= 51.95 KNS Vs= 0.00 KNS
Tu= 0.18 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 14J____________________ 5000X 250X 300_____________________ 15J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 4056| | | | | | | | | | | | |2No12|H| 57.4375.TO|5000 |
||============================================================ =========||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 52

ACI 318-11 BEAM NO. 15 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 15 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 35.06 KNS Vc= 51.95 KNS Vs= 0.00 KNS
Tu= 0.18 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 35.17 KNS Vc= 51.95 KNS Vs= 0.00 KNS
Tu= 0.18 KN-MET Tc= 1.6 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 15J____________________ 5000X 250X 300_____________________ 16J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 53

ACI 318-11 BEAM NO. 16 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 16 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 38.28 KNS Vc= 51.55 KNS Vs= 0.00 KNS
Tu= 2.40 KN-MET Tc= 1.6 KN-MET Ts= 3.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.99 SQ.CM.

AT END SUPPORT - Vu= 6.84 KNS Vc= 51.55 KNS Vs= 0.00 KNS
Tu= 2.40 KN-MET Tc= 1.6 KN-MET Ts= 3.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.99 SQ.CM.

___ 16J____________________ 2499X 250X 300_____________________ 107J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 54

ACI 318-11 BEAM NO. 17 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 17 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 13.13 KNS Vc= 52.94 KNS Vs= 0.00 KNS
Tu= 0.51 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 14.87 KNS Vc= 52.94 KNS Vs= 0.00 KNS
Tu= 0.51 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 6J____________________ 2500X 250X 300_____________________ 17J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO 2500 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 55

ACI 318-11 BEAM NO. 18 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 18 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 30.92 KNS Vc= 52.50 KNS Vs= 0.00 KNS
Tu= 0.78 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 31.61 KNS Vc= 52.50 KNS Vs= 0.00 KNS
Tu= 0.78 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 17J____________________ 5000X 250X 300_____________________ 18J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 56

ACI 318-11 BEAM NO. 19 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 19 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 39.50 KNS Vc= 52.26 KNS Vs= 0.41 KNS
Tu= 2.48 KN-MET Tc= 1.6 KN-MET Ts= 3.3 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.02 SQ.CM.

AT END SUPPORT - Vu= 11.50 KNS Vc= 52.26 KNS Vs= 0.00 KNS
Tu= 2.48 KN-MET Tc= 1.6 KN-MET Ts= 3.3 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.02 SQ.CM.

___ 18J____________________ 2500X 250X 300_____________________ 99J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 57

ACI 318-11 BEAM NO. 20 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 4056. YES NO


2 57. 2 - 12MM 4374. 5000. NO YES
3 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 20 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 31.57 KNS Vc= 52.50 KNS Vs= 0.00 KNS
Tu= 0.66 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 30.96 KNS Vc= 52.50 KNS Vs= 0.00 KNS
Tu= 0.66 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 19J____________________ 5000X 250X 300_____________________ 20J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 4056| | | | | | | | | | | | |2No12|H| 57.4374.TO|5000 |
||============================================================ =========||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 58

ACI 318-11 BEAM NO. 21 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 21 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 14.77 KNS Vc= 52.94 KNS Vs= 0.00 KNS
Tu= 0.47 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 13.23 KNS Vc= 52.94 KNS Vs= 0.00 KNS
Tu= 0.47 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 20J____________________ 2500X 250X 300_____________________ 7J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO 2500 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 59

ACI 318-11 BEAM NO. 22 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 22 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 1.80 KNS Vc= 50.92 KNS Vs= 0.00 KNS
Tu= 8.26 KN-MET Tc= 1.7 KN-MET Ts= 11.0 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.40 SQ.CM.

AT END SUPPORT - Vu= 1.80 KNS Vc= 53.76 KNS Vs= 0.00 KNS
Tu= 8.26 KN-MET Tc= 1.7 KN-MET Ts= 11.0 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.40 SQ.CM.

___ 17J____________________ 2500X 250X 300_____________________ 21J____


| |
||=========================================================================||
| 2No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 2No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 60

ACI 318-11 BEAM NO. 23 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 23 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 1.80 KNS Vc= 50.89 KNS Vs= 0.00 KNS
Tu= 8.26 KN-MET Tc= 1.7 KN-MET Ts= 11.0 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.40 SQ.CM.

AT END SUPPORT - Vu= 1.80 KNS Vc= 53.48 KNS Vs= 0.00 KNS
Tu= 8.26 KN-MET Tc= 1.7 KN-MET Ts= 11.0 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.40 SQ.CM.

___ 20J____________________ 2500X 250X 300_____________________ 22J____


| |
||=========================================================================||
| 2No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 2No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 61

ACI 318-11 BEAM NO. 24 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 24 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 20.84 KNS Vc= 51.89 KNS Vs= 0.00 KNS
Tu= 8.09 KN-MET Tc= 1.8 KN-MET Ts= 10.8 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.33 SQ.CM.

AT END SUPPORT - Vu= 20.84 KNS Vc= 51.96 KNS Vs= 0.00 KNS
Tu= 8.09 KN-MET Tc= 1.8 KN-MET Ts= 10.8 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.33 SQ.CM.

___ 21J____________________ 2500X 250X 300_____________________ 120J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 62

ACI 318-11 BEAM NO. 25 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 25 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 20.84 KNS Vc= 51.89 KNS Vs= 0.00 KNS
Tu= 8.09 KN-MET Tc= 1.8 KN-MET Ts= 10.8 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.33 SQ.CM.

AT END SUPPORT - Vu= 20.84 KNS Vc= 51.96 KNS Vs= 0.00 KNS
Tu= 8.09 KN-MET Tc= 1.8 KN-MET Ts= 10.8 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.33 SQ.CM.

___ 22J____________________ 2500X 250X 300_____________________ 119J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 63

ACI 318-11 BEAM NO. 26 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 4 - 12MM 0. 5000. YES YES

B E A M N O. 26 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.81 KNS Vc= 96.37 KNS Vs= 0.00 KNS
Tu= 8.51 KN-MET Tc= 1.8 KN-MET Ts= 11.3 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.50 SQ.CM.

AT END SUPPORT - Vu= 0.81 KNS Vc= 96.37 KNS Vs= 0.00 KNS
Tu= 8.51 KN-MET Tc= 1.8 KN-MET Ts= 11.3 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.50 SQ.CM.

___ 23J____________________ 5000X 250X 300_____________________ 25J____


| |
||=========================================================================||
| 4No12 H 243.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 64

ACI 318-11 BEAM NO. 27 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 27 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.81 KNS Vc= 96.37 KNS Vs= 0.00 KNS
Tu= 8.51 KN-MET Tc= 1.8 KN-MET Ts= 11.3 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.50 SQ.CM.

AT END SUPPORT - Vu= 0.81 KNS Vc= 96.37 KNS Vs= 0.00 KNS
Tu= 8.51 KN-MET Tc= 1.8 KN-MET Ts= 11.3 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.50 SQ.CM.

___ 24J____________________ 5000X 250X 300_____________________ 26J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 65

ACI 318-11 BEAM NO. 28 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 0. YES NO


2 57. 2 - 12MM 706. 5000. NO YES
3 241. 3 - 16MM 0. 5000. YES YES

B E A M N O. 28 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 42.16 KNS Vc= 52.95 KNS Vs= 3.26 KNS
Tu= 0.55 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 42.38 KNS Vc= 52.95 KNS Vs= 3.55 KNS
Tu= 0.55 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 25J____________________ 5000X 250X 300_____________________ 27J____


| |
||=========================================================================||
| 3No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.12|0.TO7. 706.TO|5000 | | | | | | | | | | | | | | | | | | | | |
|| =================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 66

ACI 318-11 BEAM NO. 29 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 29 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 42.48 KNS Vc= 52.94 KNS Vs= 3.70 KNS
Tu= 1.80 KN-MET Tc= 1.7 KN-MET Ts= 2.4 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.74 SQ.CM.

AT END SUPPORT - Vu= 4.63 KNS Vc= 52.94 KNS Vs= 0.00 KNS
Tu= 1.80 KN-MET Tc= 1.7 KN-MET Ts= 2.4 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.74 SQ.CM.

___ 27J____________________ 2500X 250X 300_____________________ 108J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 2No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 67

ACI 318-11 BEAM NO. 30 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 4086. YES NO


2 57. 2 - 12MM 4792. 5000. NO YES
3 241. 3 - 16MM 0. 5000. YES YES

B E A M N O. 30 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 42.36 KNS Vc= 52.96 KNS Vs= 3.52 KNS
Tu= 0.47 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 42.18 KNS Vc= 52.96 KNS Vs= 3.28 KNS
Tu= 0.47 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 28J____________________ 5000X 250X 300_____________________ 26J____


| |
||=========================================================================||
| 3No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 4086| | | | | | | | | | | | |2No12|H| 57.4792.TO 5000 |
||============================================================= ===||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 68

ACI 318-11 BEAM NO. 87 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 87 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 37.51 KNS Vc= 52.17 KNS Vs= 0.00 KNS
Tu= 3.12 KN-MET Tc= 1.8 KN-MET Ts= 4.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.29 SQ.CM.

AT END SUPPORT - Vu= 6.07 KNS Vc= 50.87 KNS Vs= 0.00 KNS
Tu= 3.12 KN-MET Tc= 1.8 KN-MET Ts= 4.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.29 SQ.CM.

___ 68J____________________ 2500X 250X 300_____________________ 113J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 69

ACI 318-11 BEAM NO. 88 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 4473. YES NO


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 88 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 35.21 KNS Vc= 51.84 KNS Vs= 0.00 KNS
Tu= 0.51 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 35.03 KNS Vc= 51.86 KNS Vs= 0.00 KNS
Tu= 0.51 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 70J____________________ 5000X 250X 300_____________________ 71J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122 |
| 2No12 H |57.| |0.TO 4473| | | | | | | | | | | | | | | | | | | | | |
||================================================================== |
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | |
| oo | | oo | | oo | | oo | | |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 70

ACI 318-11 BEAM NO. 89 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 89 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 35.03 KNS Vc= 51.86 KNS Vs= 0.00 KNS
Tu= 0.51 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 35.21 KNS Vc= 51.84 KNS Vs= 0.00 KNS
Tu= 0.51 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 71J____________________ 5000X 250X 300_____________________ 72J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 71

ACI 318-11 BEAM NO. 90 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 90 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 38.58 KNS Vc= 51.99 KNS Vs= 0.00 KNS
Tu= 2.35 KN-MET Tc= 1.7 KN-MET Ts= 3.1 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.97 SQ.CM.

AT END SUPPORT - Vu= 7.13 KNS Vc= 50.93 KNS Vs= 0.00 KNS
Tu= 2.35 KN-MET Tc= 1.7 KN-MET Ts= 3.1 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.97 SQ.CM.

___ 72J____________________ 2499X 250X 300_____________________ 114J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 72

ACI 318-11 BEAM NO. 91 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 91 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 38.28 KNS Vc= 52.24 KNS Vs= 0.00 KNS
Tu= 3.05 KN-MET Tc= 1.8 KN-MET Ts= 4.1 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.26 SQ.CM.

AT END SUPPORT - Vu= 6.82 KNS Vc= 50.91 KNS Vs= 0.00 KNS
Tu= 3.05 KN-MET Tc= 1.8 KN-MET Ts= 4.1 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.26 SQ.CM.

___ 69J____________________ 2500X 250X 300_____________________ 115J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 73

ACI 318-11 BEAM NO. 92 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 92 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.59 KNS Vc= 44.34 KNS Vs= 0.00 KNS
Tu= 4.42 KN-MET Tc= 1.4 KN-MET Ts= 5.9 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.82 SQ.CM.

AT END SUPPORT - Vu= 0.59 KNS Vc= 44.34 KNS Vs= 0.00 KNS
Tu= 4.42 KN-MET Tc= 1.4 KN-MET Ts= 5.9 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.82 SQ.CM.

___ 67J____________________ 5000X 250X 300_____________________ 65J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 74

ACI 318-11 BEAM NO. 93 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 93 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.83 KNS Vc= 49.07 KNS Vs= 0.00 KNS
Tu= 6.16 KN-MET Tc= 1.5 KN-MET Ts= 8.2 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.54 SQ.CM.

AT END SUPPORT - Vu= 0.83 KNS Vc= 49.07 KNS Vs= 0.00 KNS
Tu= 6.16 KN-MET Tc= 1.5 KN-MET Ts= 8.2 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.54 SQ.CM.

___ 65J____________________ 5000X 250X 300_____________________ 63J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 75

ACI 318-11 BEAM NO. 94 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 94 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 35.94 KNS Vc= 51.83 KNS Vs= 0.00 KNS
Tu= 0.50 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 34.32 KNS Vc= 52.00 KNS Vs= 0.00 KNS
Tu= 0.50 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 63J____________________ 5000X 250X 300_____________________ 61J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 76

ACI 318-11 BEAM NO. 95 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 4 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 95 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 49.53 KNS Vc= 53.20 KNS Vs= 12.83 KNS
Tu= 3.38 KN-MET Tc= 1.8 KN-MET Ts= 4.5 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.39 SQ.CM.

AT END SUPPORT - Vu= 18.07 KNS Vc= 51.61 KNS Vs= 0.00 KNS
Tu= 3.38 KN-MET Tc= 1.8 KN-MET Ts= 4.5 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.39 SQ.CM.

___ 61J____________________ 2500X 250X 300_____________________ 110J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 4No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| oooo | | oooo | | oooo | | oooo | | oooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 77

ACI 318-11 BEAM NO. 96 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 1290. YES NO
3 241. 2 - 16MM 1835. 5000. NO YES

B E A M N O. 96 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 35.52 KNS Vc= 51.81 KNS Vs= 0.00 KNS
Tu= 0.48 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 34.74 KNS Vc= 51.88 KNS Vs= 0.00 KNS
Tu= 0.48 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 60J____________________ 5000X 250X 300_____________________ 59J____


| |
||================== ================================================||
| 2No16 H 241.| |0.TO 1290 2No16 H 241.1835.TO 5000| | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000 | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 78

ACI 318-11 BEAM NO. 97 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 97 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 34.72 KNS Vc= 51.88 KNS Vs= 0.00 KNS
Tu= 0.47 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 35.54 KNS Vc= 51.80 KNS Vs= 0.00 KNS
Tu= 0.47 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 59J____________________ 5000X 250X 300_____________________ 58J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 79

ACI 318-11 BEAM NO. 98 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 3 - 16MM 0. 2500. YES YES


2 241. 4 - 16MM 0. 2500. YES YES

B E A M N O. 98 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 52.77 KNS Vc= 52.73 KNS Vs= 17.63 KNS
Tu= 4.38 KN-MET Tc= 1.8 KN-MET Ts= 5.8 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.80 SQ.CM.

AT END SUPPORT - Vu= 21.31 KNS Vc= 51.42 KNS Vs= 0.00 KNS
Tu= 4.38 KN-MET Tc= 1.8 KN-MET Ts= 5.8 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.80 SQ.CM.

___ 58J____________________ 2500X 250X 300_____________________ 109J____


| |
||=========================================================================||
| 4No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No16 H 59.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#16 | | 4#16 | | 4#16 | | 4#16 | | 4#16 |
| | | | | | | | | |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 80

ACI 318-11 BEAM NO. 99 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 99 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 34.32 KNS Vc= 52.00 KNS Vs= 0.00 KNS
Tu= 0.52 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 35.94 KNS Vc= 51.83 KNS Vs= 0.00 KNS
Tu= 0.52 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 57J____________________ 5000X 250X 300_____________________ 62J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 81

ACI 318-11 BEAM NO. 100 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 100 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.83 KNS Vc= 49.07 KNS Vs= 0.00 KNS
Tu= 6.16 KN-MET Tc= 1.5 KN-MET Ts= 8.2 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.54 SQ.CM.

AT END SUPPORT - Vu= 0.83 KNS Vc= 49.07 KNS Vs= 0.00 KNS
Tu= 6.16 KN-MET Tc= 1.5 KN-MET Ts= 8.2 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.54 SQ.CM.

___ 62J____________________ 5000X 250X 300_____________________ 64J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 82

ACI 318-11 BEAM NO. 101 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 101 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.59 KNS Vc= 44.34 KNS Vs= 0.00 KNS
Tu= 4.42 KN-MET Tc= 1.4 KN-MET Ts= 5.9 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.82 SQ.CM.

AT END SUPPORT - Vu= 0.59 KNS Vc= 44.34 KNS Vs= 0.00 KNS
Tu= 4.42 KN-MET Tc= 1.4 KN-MET Ts= 5.9 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.82 SQ.CM.

___ 64J____________________ 5000X 250X 300_____________________ 66J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 83

ACI 318-11 BEAM NO. 102 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 102 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 1.72 KNS Vc= 44.63 KNS Vs= 0.00 KNS
Tu= 3.38 KN-MET Tc= 1.4 KN-MET Ts= 4.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.39 SQ.CM.

AT END SUPPORT - Vu= 1.72 KNS Vc= 44.63 KNS Vs= 0.00 KNS
Tu= 3.38 KN-MET Tc= 1.4 KN-MET Ts= 4.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.39 SQ.CM.

___ 66J____________________ 2499X 250X 300_____________________ 116J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 84

ACI 318-11 BEAM NO. 103 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 706. 5000. NO YES


2 241. 3 - 16MM 0. 5000. YES YES

B E A M N O. 103 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 42.15 KNS Vc= 51.93 KNS Vs= 4.26 KNS
Tu= 0.57 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 42.39 KNS Vc= 51.91 KNS Vs= 4.61 KNS
Tu= 0.57 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 81J____________________ 5000X 250X 300_____________________ 83J____


| |
||=========================================================================||
| 3No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| |2No12|H| 57. 706.TO|5000 | | | | | | | | | | | | | | | | | | | | |
| =================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 85

ACI 318-11 BEAM NO. 104 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 104 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 43.06 KNS Vc= 52.00 KNS Vs= 5.41 KNS
Tu= 1.65 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 1014. MM

AT END SUPPORT - Vu= 5.20 KNS Vc= 50.80 KNS Vs= 0.00 KNS
Tu= 1.65 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 83J____________________ 2500X 250X 300_____________________ 112J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | |
| 10*12c/c122 | | | | | | | |
| 3No12 H |57.| 0.TO 2500| | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 86

ACI 318-11 BEAM NO. 105 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 4086. YES NO


2 241. 3 - 16MM 0. 5000. YES YES

B E A M N O. 105 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 42.38 KNS Vc= 51.91 KNS Vs= 4.59 KNS
Tu= 0.49 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 42.16 KNS Vc= 51.93 KNS Vs= 4.28 KNS
Tu= 0.49 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 84J____________________ 5000X 250X 300_____________________ 82J____


| |
||=========================================================================||
| 3No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122 |
| 2No12 H |57.| |0.TO 4086| | | | | | | | | | | | | | | | | | | |
||============================================================= |
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | |
| oo | | oo | | oo | | oo | | |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 87

ACI 318-11 BEAM NO. 106 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 106 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.76 KNS Tu= 13.7 KN-MET


Vc= 97.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 0.76 KNS Tu= 13.7 KN-MET
Vc= 97.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 82J____________________ 5000X 250X 300_____________________ 80J____


| |
||=========================================================================||
| 2No16 H 241. 0.TO 5000 |
| |
| 2No12 H 57. 0.TO 5000 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 88

ACI 318-11 BEAM NO. 107 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 107 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 19.96 KNS Tu= 24.5 KN-MET


Vc= 52.0 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 19.96 KNS Tu= 24.5 KN-MET
Vc= 51.8 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 80J____________________ 2499X 250X 300_____________________ 117J____


| |
||=========================================================================||
| 4No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 89

ACI 318-11 BEAM NO. 108 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 108 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.21 KNS Tu= 12.3 KN-MET


Vc= 95.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 0.21 KNS Tu= 12.3 KN-MET
Vc= 95.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 78J____________________ 2500X 250X 300_____________________ 76J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO 2500 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 90

ACI 318-11 BEAM NO. 109 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 109 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 30.96 KNS Vc= 51.87 KNS Vs= 0.00 KNS
Tu= 0.67 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 31.57 KNS Vc= 51.81 KNS Vs= 0.00 KNS
Tu= 0.67 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 76J____________________ 5000X 250X 300_____________________ 75J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 91

ACI 318-11 BEAM NO. 110 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 110 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 8.25 KNS Vc= 53.17 KNS Vs= 0.00 KNS
Tu= 3.09 KN-MET Tc= 1.7 KN-MET Ts= 4.1 KN-MET LOAD 5
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.27 SQ.CM.

AT END SUPPORT - Vu= 8.25 KNS Vc= 53.17 KNS Vs= 0.00 KNS
Tu= 3.09 KN-MET Tc= 1.7 KN-MET Ts= 4.1 KN-MET LOAD 5
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.27 SQ.CM.

___ 75J____________________ 2499X 250X 300_____________________ 111J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 92

ACI 318-11 BEAM NO. 111 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 111 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 31.60 KNS Vc= 51.81 KNS Vs= 0.00 KNS
Tu= 0.79 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 30.93 KNS Vc= 51.88 KNS Vs= 0.00 KNS
Tu= 0.79 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 74J____________________ 5000X 250X 300_____________________ 73J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 93

ACI 318-11 BEAM NO. 112 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 112 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.21 KNS Tu= 12.3 KN-MET


Vc= 95.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 0.21 KNS Tu= 12.3 KN-MET
Vc= 95.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 73J____________________ 2500X 250X 300_____________________ 77J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO 2500 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 94

ACI 318-11 BEAM NO. 113 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 113 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 20.18 KNS Tu= 9.5 KN-MET


Vc= 51.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 20.18 KNS Tu= 9.5 KN-MET
Vc= 51.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 77J____________________ 2500X 250X 300_____________________ 118J____


| |
||=========================================================================||
| 4No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 95

ACI 318-11 BEAM NO. 114 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 4 - 12MM 0. 5000. YES YES

B E A M N O. 114 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.76 KNS Tu= 13.7 KN-MET


Vc= 97.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 0.76 KNS Tu= 13.7 KN-MET
Vc= 97.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 79J____________________ 5000X 250X 300_____________________ 81J____


| |
||=========================================================================||
| 4No12 H 243. 0.TO 5000 |
| |
| 2No12 H 57. 0.TO 5000 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 96

ACI 318-11 BEAM NO. 127 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 2 - 12MM 0. 5000. YES YES

B E A M N O. 127 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.66 KNS Vc= 25.58 KNS Vs= 0.00 KNS
Tu= 0.20 KN-MET Tc= NaN KN-MET Ts= 0.3 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.08 SQ.CM.

AT END SUPPORT - Vu= 0.66 KNS Vc= 25.58 KNS Vs= 0.00 KNS
Tu= 0.20 KN-MET Tc= NaN KN-MET Ts= 0.3 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.08 SQ.CM.

___ 93J____________________ 5000X 250X 300_____________________ 95J____


| |
||=========================================================================||
| 2No12 H 243.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 97

ACI 318-11 BEAM NO. 128 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 2 - 12MM 0. 5000. YES YES

B E A M N O. 128 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.00 KNS Vc= 25.77 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= NaN KN-MET Ts= 0.0 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2263. MM

AT END SUPPORT - Vu= 0.00 KNS Vc= 25.77 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= NaN KN-MET Ts= 0.0 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2263. MM

___ 95J____________________ 4999X 250X 300_____________________ 96J____


| |
||=========================================================================||
| 2No12 H 243.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 98

ACI 318-11 BEAM NO. 129 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 2 - 12MM 0. 5000. YES YES

B E A M N O. 129 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.66 KNS Vc= 25.58 KNS Vs= 0.00 KNS
Tu= 0.20 KN-MET Tc= NaN KN-MET Ts= 0.3 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.08 SQ.CM.

AT END SUPPORT - Vu= 0.66 KNS Vc= 25.58 KNS Vs= 0.00 KNS
Tu= 0.20 KN-MET Tc= NaN KN-MET Ts= 0.3 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.08 SQ.CM.

___ 96J____________________ 5000X 250X 300_____________________ 94J____


| |
||=========================================================================||
| 2No12 H 243.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 99

ACI 318-11 BEAM NO. 130 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 3 - 12MM 0. 2500. YES YES

B E A M N O. 130 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 18.28 KNS Tu= 16.1 KN-MET


Vc= 52.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 18.28 KNS Tu= 16.1 KN-MET
Vc= 52.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 94J____________________ 2499X 250X 300_____________________ 124J____


| |
||=========================================================================||
| 3No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 100

ACI 318-11 BEAM NO. 131 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 3 - 12MM 0. 2500. YES YES

B E A M N O. 131 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 19.10 KNS Vc= 52.16 KNS Vs= 0.00 KNS
Tu= 8.62 KN-MET Tc= 1.6 KN-MET Ts= 11.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.55 SQ.CM.

AT END SUPPORT - Vu= 19.10 KNS Vc= 52.16 KNS Vs= 0.00 KNS
Tu= 8.62 KN-MET Tc= 1.6 KN-MET Ts= 11.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.55 SQ.CM.

___ 92J____________________ 2499X 250X 300_____________________ 122J____


| |
||=========================================================================||
| 3No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 101

ACI 318-11 BEAM NO. 132 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 132 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 2.12 KNS Tu= 15.0 KN-MET


Vc= 51.1 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 2.12 KNS Tu= 15.0 KN-MET
Vc= 51.1 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 90J____________________ 2500X 250X 300_____________________ 88J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO 2500 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 102

ACI 318-11 BEAM NO. 133 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 2 - 12MM 0. 3676. YES NO

B E A M N O. 133 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.63 KNS Vc= 25.35 KNS Vs= 0.00 KNS
Tu= 0.10 KN-MET Tc= NaN KN-MET Ts= 0.1 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.04 SQ.CM.

AT END SUPPORT - Vu= 0.63 KNS Vc= 25.35 KNS Vs= 0.00 KNS
Tu= 0.10 KN-MET Tc= NaN KN-MET Ts= 0.1 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.04 SQ.CM.

___ 88J____________________ 5000X 250X 300_____________________ 87J____


| |
||====================================================== |
| 2No12 H 243.| |0.TO 3676| | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | 26*12c/c 93 |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | | | |
| 2#12 | | 2#12 | | 2#12 | | | | |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 103

ACI 318-11 BEAM NO. 134 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 2 - 12MM 0. 5000. YES YES

B E A M N O. 134 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.00 KNS Vc= 25.52 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= NaN KN-MET Ts= 0.0 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2263. MM

AT END SUPPORT - Vu= 0.00 KNS Vc= 25.52 KNS Vs= 0.00 KNS
Tu= 0.00 KN-MET Tc= NaN KN-MET Ts= 0.0 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2263. MM

___ 87J____________________ 4999X 250X 300_____________________ 86J____


| |
||=========================================================================||
| 2No12 H 243.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 104

ACI 318-11 BEAM NO. 135 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 2 - 12MM 699. 5000. NO YES

B E A M N O. 135 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.63 KNS Vc= 25.35 KNS Vs= 0.00 KNS
Tu= 0.10 KN-MET Tc= NaN KN-MET Ts= 0.1 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.04 SQ.CM.

AT END SUPPORT - Vu= 0.63 KNS Vc= 25.35 KNS Vs= 0.00 KNS
Tu= 0.10 KN-MET Tc= NaN KN-MET Ts= 0.1 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.04 SQ.CM.

___ 86J____________________ 5000X 250X 300_____________________ 85J____


| |
| =================================================================||
| |2No12|H|243. 699.TO|5000 | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| | | oo | | oo | | oo | | oo |
| | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 105

ACI 318-11 BEAM NO. 136 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 136 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 2.12 KNS Tu= 15.0 KN-MET


Vc= 51.1 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 2.12 KNS Tu= 15.0 KN-MET
Vc= 51.1 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 85J____________________ 2500X 250X 300_____________________ 89J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO 2500 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 106

ACI 318-11 BEAM NO. 137 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 3 - 12MM 0. 2500. YES YES

B E A M N O. 137 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 18.02 KNS Vc= 52.16 KNS Vs= 0.00 KNS
Tu= 8.62 KN-MET Tc= 1.6 KN-MET Ts= 11.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.55 SQ.CM.

AT END SUPPORT - Vu= 18.02 KNS Vc= 52.16 KNS Vs= 0.00 KNS
Tu= 8.62 KN-MET Tc= 1.6 KN-MET Ts= 11.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.55 SQ.CM.

___ 89J____________________ 2500X 250X 300_____________________ 121J____


| |
||=========================================================================||
| 3No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 107

ACI 318-11 BEAM NO. 138 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 3 - 12MM 0. 2500. YES YES

B E A M N O. 138 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 18.84 KNS Tu= 16.1 KN-MET


Vc= 52.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 18.84 KNS Tu= 16.1 KN-MET
Vc= 52.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.

___ 91J____________________ 2500X 250X 300_____________________ 123J____


| |
||=========================================================================||
| 3No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 108

ACI 318-11 BEAM NO. 139 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 4 - 12MM 0. 2500. YES YES


2 241. 4 - 16MM 0. 2500. YES YES

B E A M N O. 139 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 20.83 KNS Vc= 50.23 KNS Vs= 0.00 KNS
Tu= 4.53 KN-MET Tc= 1.6 KN-MET Ts= 6.0 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.87 SQ.CM.

AT END SUPPORT - Vu= 52.29 KNS Vc= 50.23 KNS Vs= 19.48 KNS
Tu= 4.53 KN-MET Tc= 1.6 KN-MET Ts= 6.0 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.87 SQ.CM.

___ 97J____________________ 2500X 250X 300_____________________ 2J____


| |
||=========================================================================||
| 4No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 4No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#16 | | 4#16 | | 4#16 | | 4#16 | | 4#16 |
| | | | | | | | | |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| oooo | | oooo | | oooo | | oooo | | oooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 109

ACI 318-11 BEAM NO. 140 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 5000. YES YES


2 241. 4 - 16MM 0. 5000. YES YES

B E A M N O. 140 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 47.37 KNS Vc= 53.10 KNS Vs= 10.06 KNS
Tu= 0.14 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 29.64 KNS Vc= 53.10 KNS Vs= 0.00 KNS
Tu= 0.14 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 17J____________________ 5000X 250X 300_____________________ 97J____


| |
||=========================================================================||
| 4No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 3No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#16 | | 4#16 | | 4#16 | | 4#16 | | 4#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 110

ACI 318-11 BEAM NO. 141 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 4 - 12MM 0. 2500. YES YES


2 239. 2 - 20MM 0. 2500. YES YES

B E A M N O. 141 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 18.78 KNS Vc= 50.36 KNS Vs= 0.00 KNS
Tu= 3.90 KN-MET Tc= 1.6 KN-MET Ts= 5.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.61 SQ.CM.

AT END SUPPORT - Vu= 50.24 KNS Vc= 50.36 KNS Vs= 16.62 KNS
Tu= 3.90 KN-MET Tc= 1.6 KN-MET Ts= 5.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.61 SQ.CM.

___ 98J____________________ 2500X 250X 300_____________________ 5J____


| |
||=========================================================================||
| 2No20 H 239.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 4No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#20 | | 2#20 | | 2#20 | | 2#20 | | 2#20 |
| | | | | | | | | |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| oooo | | oooo | | oooo | | oooo | | oooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 111

ACI 318-11 BEAM NO. 142 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 5000. YES YES


2 239. 2 - 20MM 0. 5000. YES YES

B E A M N O. 142 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 43.65 KNS Vc= 53.10 KNS Vs= 5.09 KNS
Tu= 0.13 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 27.13 KNS Vc= 53.10 KNS Vs= 0.00 KNS
Tu= 0.13 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

___ 20J____________________ 5000X 250X 300_____________________ 98J____


| |
||=========================================================================||
| 2No20 H 239.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | | | | | | | | | | |20*12c/c122| | |
| 3No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#20 | | 2#20 | | 2#20 | | 2#20 | | 2#20 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 112

ACI 318-11 BEAM NO. 143 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 143 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 9.23 KNS Vc= 51.78 KNS Vs= 0.00 KNS
Tu= 2.90 KN-MET Tc= 1.7 KN-MET Ts= 3.9 KN-MET LOAD 3
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.19 SQ.CM.

AT END SUPPORT - Vu= 9.23 KNS Vc= 51.69 KNS Vs= 0.00 KNS
Tu= 2.90 KN-MET Tc= 1.7 KN-MET Ts= 3.9 KN-MET LOAD 3
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.19 SQ.CM.

___ 99J____________________ 2499X 250X 300_____________________ 19J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 113

ACI 318-11 BEAM NO. 144 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 3 - 12MM 0. 5000. YES YES

B E A M N O. 144 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 23.45 KNS Vc= 52.99 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 14.55 KNS Vc= 52.99 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 3J____________________ 5000X 250X 300_____________________ 99J____


| |
||=========================================================================||
| 3No12 H 243.| |0.TO 5000| | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 114

ACI 318-11 BEAM NO. 147 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 147 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 7.48 KNS Vc= 51.36 KNS Vs= 0.00 KNS
Tu= 2.54 KN-MET Tc= 1.6 KN-MET Ts= 3.4 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.05 SQ.CM.

AT END SUPPORT - Vu= 38.94 KNS Vc= 51.36 KNS Vs= 0.57 KNS
Tu= 2.54 KN-MET Tc= 1.6 KN-MET Ts= 3.4 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.05 SQ.CM.

___ 102J____________________ 2500X 250X 300_____________________ 13J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 115

ACI 318-11 BEAM NO. 148 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 148 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 33.82 KNS Vc= 53.09 KNS Vs= 0.00 KNS
Tu= 0.21 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 1014. MM

AT END SUPPORT - Vu= 4.03 KNS Vc= 53.09 KNS Vs= 0.00 KNS
Tu= 0.21 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 26J____________________ 2500X 250X 300_____________________ 102J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | |
| 10*12c/c122 | | | | | | | |
| 2No12 H |57.| 0.TO 2500| | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 116

ACI 318-11 BEAM NO. 149 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 342. YES NO
3 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 149 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 7.44 KNS Vc= 51.36 KNS Vs= 0.00 KNS
Tu= 2.55 KN-MET Tc= 1.6 KN-MET Ts= 3.4 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.05 SQ.CM.

AT END SUPPORT - Vu= 38.91 KNS Vc= 51.36 KNS Vs= 0.52 KNS
Tu= 2.55 KN-MET Tc= 1.6 KN-MET Ts= 3.4 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.05 SQ.CM.

___ 103J____________________ 2500X 250X 300_____________________ 12J____


| |
||=========================================================================||
| 2No12 H 243.| 0.TO 2342| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 117

ACI 318-11 BEAM NO. 150 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 150 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 33.84 KNS Vc= 53.09 KNS Vs= 0.00 KNS
Tu= 0.24 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 1014. MM

AT END SUPPORT - Vu= 4.01 KNS Vc= 53.09 KNS Vs= 0.00 KNS
Tu= 0.24 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 25J____________________ 2500X 250X 300_____________________ 103J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | |
| 10*12c/c122 | | | | | | | |
| 2No12 H |57.| 0.TO 2500| | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|
STAAD SPACE -- PAGE NO. 118

ACI 318-11 BEAM NO. 155 DESIGN RESULTS


=============================================

LEN - 12500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 3 - 16MM 0. 12500. YES YES

*** A SUITABLE BAR ARRANGEMENT COULD NOT BE DETERMINED.


REQD. STEEL = 1248. MM2, MAX. STEEL PERMISSIBLE = 1251. MM2
MAX NEG MOMENT = 88.92 KN-MET, LOADING 1

___ 28J____________________ 12500X 250X 300_____________________ 19J____


| |
| |
| |
| |
| 3No16 H 59. 0.TO12500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 156 DESIGN RESULTS


=============================================

LEN - 12500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 1. YES NO


2 59. 4 - 16MM 2102. 12500. NO YES
STAAD SPACE -- PAGE NO. 119

***MEMBER FAILS IN MAX REINFORCEMENT.


INCREASE MEMBER SIZE.
MAX NEG MOMENT = 106.86 KN-MET, LOADING 1

___ 27J____________________ 12500X 250X 300_____________________ 18J____


| |
| |
| |
| |
| 2No12 H 57.No10.TO 59.1102.TO12500 |
|| ===============================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| 2#12 | | 4#16 | | 4#16 | | 4#16 | | 4#16 |
| oo | | oooo | | oooo | | oooo | | oooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 157 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 157 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 7.41 KNS Vc= 51.51 KNS Vs= 0.00 KNS
Tu= 2.41 KN-MET Tc= 1.6 KN-MET Ts= 3.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.99 SQ.CM.
STAAD SPACE -- PAGE NO. 120

AT END SUPPORT - Vu= 38.85 KNS Vc= 51.51 KNS Vs= 0.30 KNS
Tu= 2.41 KN-MET Tc= 1.6 KN-MET Ts= 3.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.99 SQ.CM.

___ 106J____________________ 2500X 250X 300_____________________ 14J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 158 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 158 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 31.65 KNS Vc= 53.17 KNS Vs= 0.00 KNS
Tu= 0.13 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 1014. MM
STAAD SPACE -- PAGE NO. 121

AT END SUPPORT - Vu= 2.83 KNS Vc= 53.17 KNS Vs= 0.00 KNS
Tu= 0.13 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 25J____________________ 2500X 250X 300_____________________ 106J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | |
| 10*12c/c122 | | | | | | | |
| 2No12 H |57.| 0.TO 2500| | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 159 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 1688. YES NO


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 159 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 6.27 KNS Vc= 51.53 KNS Vs= 0.00 KNS
Tu= 2.60 KN-MET Tc= 1.6 KN-MET Ts= 3.5 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.07 SQ.CM.
STAAD SPACE -- PAGE NO. 122

AT END SUPPORT - Vu= 37.71 KNS Vc= 51.53 KNS Vs= 0.00 KNS
Tu= 2.60 KN-MET Tc= 1.6 KN-MET Ts= 3.5 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.07 SQ.CM.

___ 107J____________________ 2500X 250X 300_____________________ 13J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | 12*12c/c 93 |
| 3No12 H 57.| 0.TO 1688| | | | | | | | |
||================================================== |
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | | | |
| ooo | | ooo | | ooo | | | | |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 160 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 160 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 29.63 KNS Vc= 53.17 KNS Vs= 0.00 KNS
Tu= 0.12 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 1014. MM
STAAD SPACE -- PAGE NO. 123

AT END SUPPORT - Vu= 2.07 KNS Vc= 53.17 KNS Vs= 0.00 KNS
Tu= 0.12 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.

___ 26J____________________ 2500X 250X 300_____________________ 107J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | |
| 10*12c/c122 | | | | | | | |
| 2No12 H |57.| 0.TO 2500| | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 161 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 161 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 4.68 KNS Vc= 52.94 KNS Vs= 0.00 KNS
Tu= 1.99 KN-MET Tc= 1.7 KN-MET Ts= 2.7 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.82 SQ.CM.
STAAD SPACE -- PAGE NO. 124

AT END SUPPORT - Vu= 42.54 KNS Vc= 52.94 KNS Vs= 3.77 KNS
Tu= 1.99 KN-MET Tc= 1.7 KN-MET Ts= 2.7 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.82 SQ.CM.

___ 108J____________________ 2499X 250X 300_____________________ 28J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 2No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 162 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 3 - 12MM 0. 2426. YES NO

B E A M N O. 162 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 18.52 KNS Vc= 53.09 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 1.50 KNS Vc= 53.09 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 125

___ 15J____________________ 2500X 250X 300_____________________ 108J____


| |
||======================================================================== |
| 3No12 H 243. 0.TO 2426 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 163 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 163 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 12.79 KNS Vc= 52.10 KNS Vs= 0.00 KNS
Tu= 0.58 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 15.21 KNS Vc= 51.33 KNS Vs= 0.00 KNS
Tu= 0.58 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 126

___ 62J____________________ 2500X 250X 300_____________________ 73J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO 2500 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 164 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2500. YES YES

B E A M N O. 164 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 15.16 KNS Vc= 51.33 KNS Vs= 0.00 KNS
Tu= 0.54 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 12.84 KNS Vc= 52.06 KNS Vs= 0.00 KNS
Tu= 0.54 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 127

___ 76J____________________ 2500X 250X 300_____________________ 63J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO 2500 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 165 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 3 - 16MM 0. 2500. YES YES


2 239. 2 - 20MM 0. 2500. YES YES

B E A M N O. 165 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 19.46 KNS Vc= 51.29 KNS Vs= 0.00 KNS
Tu= 3.84 KN-MET Tc= 1.8 KN-MET Ts= 5.1 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.58 SQ.CM.

AT END SUPPORT - Vu= 50.92 KNS Vc= 52.91 KNS Vs= 14.98 KNS
Tu= 3.84 KN-MET Tc= 1.8 KN-MET Ts= 5.1 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.58 SQ.CM.
STAAD SPACE -- PAGE NO. 128

___ 109J____________________ 2500X 250X 300_____________________ 57J____


| |
||=========================================================================||
| 2No20 H 239.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No16 H 59.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#20 | | 2#20 | | 2#20 | | 2#20 | | 2#20 |
| | | | | | | | | |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 166 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 5000. YES YES


2 241. 4 - 16MM 0. 5000. YES YES

B E A M N O. 166 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 47.60 KNS Vc= 51.88 KNS Vs= 11.59 KNS
Tu= 0.21 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 29.41 KNS Vc= 93.64 KNS Vs= 0.00 KNS
Tu= 0.21 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 129

___ 73J____________________ 5000X 250X 300_____________________ 109J____


| |
||=========================================================================||
| 4No16 H 241.| |0.TO 5000| | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | |
| 3No12 H |57.| |0.TO 5000| | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#16 | | 4#16 | | 4#16 | | 4#16 | | 4#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 167 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 4 - 12MM 0. 2500. YES YES


2 241. 4 - 16MM 0. 2500. YES YES

B E A M N O. 167 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 19.88 KNS Vc= 51.73 KNS Vs= 0.00 KNS
Tu= 3.93 KN-MET Tc= 1.8 KN-MET Ts= 5.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.62 SQ.CM.

AT END SUPPORT - Vu= 51.33 KNS Vc= 53.02 KNS Vs= 15.42 KNS
Tu= 3.93 KN-MET Tc= 1.8 KN-MET Ts= 5.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.62 SQ.CM.
STAAD SPACE -- PAGE NO. 130

___ 110J____________________ 2499X 250X 300_____________________ 60J____


| |
||=========================================================================||
| 4No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 4No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#16 | | 4#16 | | 4#16 | | 4#16 | | 4#16 |
| | | | | | | | | |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| oooo | | oooo | | oooo | | oooo | | oooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 168 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 5000. YES YES


2 239. 2 - 20MM 0. 5000. YES YES

B E A M N O. 168 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 43.87 KNS Vc= 51.76 KNS Vs= 6.74 KNS
Tu= 0.20 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 26.91 KNS Vc= 93.61 KNS Vs= 0.00 KNS
Tu= 0.20 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 131

___ 76J____________________ 5000X 250X 300_____________________ 110J____


| |
||=========================================================================||
| 2No20 H 239.| |0.TO 5000| | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | |
| 3No12 H |57.| |0.TO 5000| | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#20 | | 2#20 | | 2#20 | | 2#20 | | 2#20 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 169 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 169 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 11.76 KNS Vc= 51.19 KNS Vs= 0.00 KNS
Tu= 2.69 KN-MET Tc= 1.7 KN-MET Ts= 3.6 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.11 SQ.CM.

AT END SUPPORT - Vu= 39.76 KNS Vc= 52.24 KNS Vs= 0.77 KNS
Tu= 2.69 KN-MET Tc= 1.7 KN-MET Ts= 3.6 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.11 SQ.CM.
STAAD SPACE -- PAGE NO. 132

___ 111J____________________ 2500X 250X 300_____________________ 74J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 170 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 243. 3 - 12MM 0. 5000. YES YES

B E A M N O. 170 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 22.92 KNS Vc= 51.49 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 2264. MM

AT END SUPPORT - Vu= 15.09 KNS Vc= 68.25 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 133

___ 59J____________________ 5000X 250X 300_____________________ 111J____


| |
||=========================================================================||
| 3No12 H 243.| |0.TO 5000| | | | | | | | |
| 20*12c/c122 | | | | | | | | | | | | | | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 171 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 171 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 5.27 KNS Vc= 50.80 KNS Vs= 0.00 KNS
Tu= 1.85 KN-MET Tc= 1.7 KN-MET Ts= 2.5 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.76 SQ.CM.

AT END SUPPORT - Vu= 43.12 KNS Vc= 51.99 KNS Vs= 5.50 KNS
Tu= 1.85 KN-MET Tc= 1.7 KN-MET Ts= 2.5 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.76 SQ.CM.
STAAD SPACE -- PAGE NO. 134

___ 112J____________________ 2499X 250X 300_____________________ 84J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 172 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 2426. YES NO

B E A M N O. 172 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 17.37 KNS Vc= 50.82 KNS Vs= 0.00 KNS
Tu= 0.02 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 0.35 KNS Vc= 50.56 KNS Vs= 0.00 KNS
Tu= 0.02 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 135

___ 71J____________________ 2500X 250X 300_____________________ 112J____


| |
||======================================================================== |
| 2No12 H 243. 0.TO 2426 |
| |
| 2No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 173 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 173 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 7.69 KNS Vc= 50.97 KNS Vs= 0.00 KNS
Tu= 2.36 KN-MET Tc= 1.8 KN-MET Ts= 3.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.97 SQ.CM.

AT END SUPPORT - Vu= 39.14 KNS Vc= 52.03 KNS Vs= 0.16 KNS
Tu= 2.36 KN-MET Tc= 1.8 KN-MET Ts= 3.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR SHEAR AND TORSION.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 0.97 SQ.CM.
STAAD SPACE -- PAGE NO. 136

___ 113J____________________ 2500X 250X 300_____________________ 70J____


| |
||=========================================================================||
| 4No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 174 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 174 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 32.08 KNS Vc= 53.09 KNS Vs= 0.00 KNS
Tu= 0.23 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 1014. MM

AT END SUPPORT - Vu= 2.40 KNS Vc= 53.09 KNS Vs= 0.00 KNS
Tu= 0.23 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 137

___ 81J____________________ 2500X 250X 300_____________________ 113J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | |
| 10*12c/c122 | | | | | | | |
| 2No12 H |57.| 0.TO 2500| | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 175 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 1689. YES NO


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 175 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 5.54 KNS Vc= 50.84 KNS Vs= 0.00 KNS
Tu= 3.11 KN-MET Tc= 1.8 KN-MET Ts= 4.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.28 SQ.CM.

AT END SUPPORT - Vu= 36.99 KNS Vc= 52.12 KNS Vs= 0.00 KNS
Tu= 3.11 KN-MET Tc= 1.8 KN-MET Ts= 4.2 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.28 SQ.CM.
STAAD SPACE -- PAGE NO. 138

___ 114J____________________ 2500X 250X 300_____________________ 69J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | 12*12c/c 93 |
| 3No12 H 57.| 0.TO 1689| | | | | | | | |
||================================================== |
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | | | |
| ooo | | ooo | | ooo | | | | |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 176 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 176 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 30.05 KNS Vc= 53.11 KNS Vs= 0.00 KNS
Tu= 0.22 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 1014. MM

AT END SUPPORT - Vu= 1.64 KNS Vc= 53.11 KNS Vs= 0.00 KNS
Tu= 0.22 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 139

___ 82J____________________ 2500X 250X 300_____________________ 114J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | |
| 10*12c/c122 | | | | | | | |
| 2No12 H |57.| 0.TO 2500| | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 177 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 241. 3 - 16MM 0. 2500. YES YES

B E A M N O. 177 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 1.72 KNS Vc= 44.63 KNS Vs= 0.00 KNS
Tu= 3.38 KN-MET Tc= 1.4 KN-MET Ts= 4.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.39 SQ.CM.

AT END SUPPORT - Vu= 1.72 KNS Vc= 44.63 KNS Vs= 0.00 KNS
Tu= 3.38 KN-MET Tc= 1.4 KN-MET Ts= 4.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.39 SQ.CM.
STAAD SPACE -- PAGE NO. 140

___ 115J____________________ 2499X 250X 300_____________________ 67J____


| |
||=========================================================================||
| 3No16 H 241.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 178 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 178 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 34.19 KNS Vc= 51.17 KNS Vs= 0.00 KNS
Tu= 0.34 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 1014. MM

AT END SUPPORT - Vu= 3.67 KNS Vc= 50.78 KNS Vs= 0.00 KNS
Tu= 0.34 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 141

___ 82J____________________ 2500X 250X 300_____________________ 115J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | |
| 10*12c/c122 | | | | | | | |
| 2No12 H |57.| 0.TO 2500| | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 179 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 2 - 12MM 0. 342. YES NO
3 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 179 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 6.79 KNS Vc= 50.91 KNS Vs= 0.00 KNS
Tu= 3.06 KN-MET Tc= 1.8 KN-MET Ts= 4.1 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.26 SQ.CM.

AT END SUPPORT - Vu= 38.25 KNS Vc= 52.24 KNS Vs= 0.00 KNS
Tu= 3.06 KN-MET Tc= 1.8 KN-MET Ts= 4.1 KN-MET LOAD 1
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 1.26 SQ.CM.
STAAD SPACE -- PAGE NO. 142

___ 116J____________________ 2500X 250X 300_____________________ 68J____


| |
||=========================================================================||
| 2No12 H 243.| 0.TO 2342| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 180 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 2500. YES YES


2 241. 2 - 16MM 0. 2500. YES YES

B E A M N O. 180 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 34.19 KNS Vc= 51.17 KNS Vs= 0.00 KNS
Tu= 0.37 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 122. MM C/C FOR 1014. MM

AT END SUPPORT - Vu= 3.66 KNS Vc= 50.78 KNS Vs= 0.00 KNS
Tu= 0.37 KN-MET Tc= 1.7 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 143

___ 81J____________________ 2500X 250X 300_____________________ 116J____


| |
||=========================================================================||
| 2No16 H 241.| 0.TO 2500| | | | |
| 10*12c/c122 | | | | | | | |
| 2No12 H |57.| 0.TO 2500| | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 181 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 181 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 20.18 KNS Tu= 9.5 KN-MET


Vc= 51.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 20.18 KNS Tu= 9.5 KN-MET
Vc= 51.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
STAAD SPACE -- PAGE NO. 144

___ 117J____________________ 2500X 250X 300_____________________ 78J____


| |
||=========================================================================||
| 4No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 182 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 2 - 16MM 0. 2500. YES YES


2 239. 3 - 20MM 0. 2500. YES YES

B E A M N O. 182 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 40.14 KNS Vc= 51.47 KNS Vs= 2.04 KNS
Tu= 0.31 KN-MET Tc= 2.0 KN-MET Ts= 0.0 KN-MET LOAD 6
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 121. MM C/C FOR 1014. MM

AT END SUPPORT - Vu= 40.14 KNS Vc= 54.02 KNS Vs= 0.00 KNS
Tu= 0.31 KN-MET Tc= 2.0 KN-MET Ts= 0.0 KN-MET LOAD 6
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 121. MM C/C FOR 1014. MM
STAAD SPACE -- PAGE NO. 145

___ 65J____________________ 2500X 250X 300_____________________ 117J____


| |
||=========================================================================||
| 3No20 H 239.| 0.TO 2500| | | | | | | | | | | | | |
| 10*12c/c121 | | | | | | | | | | | | 10*12c/c121 | |
| 2No16 H |59.| 0.TO 2500| | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#20 | | 3#20 | | 3#20 | | 3#20 | | 3#20 |
| | | | | | | | | |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 183 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 183 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 19.96 KNS Tu= 24.5 KN-MET


Vc= 51.8 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 19.96 KNS Tu= 24.5 KN-MET
Vc= 52.0 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
STAAD SPACE -- PAGE NO. 146

___ 118J____________________ 2499X 250X 300_____________________ 79J____


| |
||=========================================================================||
| 4No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 184 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 2 - 16MM 0. 2500. YES YES


2 239. 3 - 20MM 0. 2500. YES YES

B E A M N O. 184 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 40.14 KNS Vc= 51.47 KNS Vs= 2.04 KNS
Tu= 0.31 KN-MET Tc= 2.0 KN-MET Ts= 0.0 KN-MET LOAD 6
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT IS REQUIRED FOR SHEAR.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 121. MM C/C FOR 1014. MM

AT END SUPPORT - Vu= 40.14 KNS Vc= 54.02 KNS Vs= 0.00 KNS
Tu= 0.31 KN-MET Tc= 2.0 KN-MET Ts= 0.0 KN-MET LOAD 6
NO STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 121. MM C/C FOR 1014. MM
STAAD SPACE -- PAGE NO. 147

___ 64J____________________ 2500X 250X 300_____________________ 118J____


| |
||=========================================================================||
| 3No20 H 239.| 0.TO 2500| | | | | | | | | | | | | |
| 10*12c/c121 | | | | | | | | | | | | 10*12c/c121 | |
| 2No16 H |59.| 0.TO 2500| | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#20 | | 3#20 | | 3#20 | | 3#20 | | 3#20 |
| | | | | | | | | |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 185 DESIGN RESULTS


=============================================

LEN - 12500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 0. YES NO


2 59. 4 - 16MM 2102. 12500. NO YES

***MEMBER FAILS IN MAX REINFORCEMENT.


INCREASE MEMBER SIZE.
MAX NEG MOMENT = 106.95 KN-MET, LOADING 1
STAAD SPACE -- PAGE NO. 148

___ 83J____________________ 12500X 250X 300_____________________ 74J____


| |
| |
| |
| |
| 2No12 H 57.No10.TO 59.0102.TO12500 |
|| ===============================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| 2#12 | | 4#16 | | 4#16 | | 4#16 | | 4#16 |
| oo | | oooo | | oooo | | oooo | | oooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 186 DESIGN RESULTS


=============================================

LEN - 12500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 59. 3 - 16MM 0. 12500. YES YES

*** A SUITABLE BAR ARRANGEMENT COULD NOT BE DETERMINED.


REQD. STEEL = 1250. MM2, MAX. STEEL PERMISSIBLE = 1251. MM2
MAX NEG MOMENT = 89.01 KN-MET, LOADING 1
STAAD SPACE -- PAGE NO. 149

___ 84J____________________ 12500X 250X 300_____________________ 75J____


| |
| |
| |
| |
| 3No16 H 59. 0.TO12500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| 3#16 | | 3#16 | | 3#16 | | 3#16 | | 3#16 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 187 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 187 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.94 KNS Vc= 49.38 KNS Vs= 0.00 KNS
Tu= 5.55 KN-MET Tc= 1.5 KN-MET Ts= 7.4 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.29 SQ.CM.

AT END SUPPORT - Vu= 0.94 KNS Vc= 49.38 KNS Vs= 0.00 KNS
Tu= 5.55 KN-MET Tc= 1.5 KN-MET Ts= 7.4 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.29 SQ.CM.
STAAD SPACE -- PAGE NO. 150

___ 10J____________________ 5000X 250X 300_____________________ 8J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 188 DESIGN RESULTS


=============================================

LEN - 5000. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 5000. YES YES


2 241. 2 - 16MM 0. 5000. YES YES

B E A M N O. 188 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.94 KNS Vc= 49.38 KNS Vs= 0.00 KNS
Tu= 5.55 KN-MET Tc= 1.5 KN-MET Ts= 7.4 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.29 SQ.CM.

AT END SUPPORT - Vu= 0.94 KNS Vc= 49.38 KNS Vs= 0.00 KNS
Tu= 5.55 KN-MET Tc= 1.5 KN-MET Ts= 7.4 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 2264. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 2.29 SQ.CM.
STAAD SPACE -- PAGE NO. 151

___ 11J____________________ 5000X 250X 300_____________________ 9J____


| |
||=========================================================================||
| 2No16 H 241.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
| 26*12c/c 93 | | | | | | | | | | | | | | | | | | | | | | | |26*12c/c 93| | |
| 2No12 H |57.| |0.TO 5000| | | | | | | | | | | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#16 | | 2#16 | | 2#16 | | 2#16 | | 2#16 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 189 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 189 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 19.70 KNS Tu= 16.8 KN-MET


Vc= 51.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 19.70 KNS Tu= 16.8 KN-MET
Vc= 51.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
STAAD SPACE -- PAGE NO. 152

___ 119J____________________ 2499X 250X 300_____________________ 24J____


| |
||=========================================================================||
| 4No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 190 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES

*** A SUITABLE BAR ARRANGEMENT COULD NOT BE DETERMINED.


REQD. STEEL = 1031. MM2, MAX. STEEL PERMISSIBLE = 1251. MM2
MAX NEG MOMENT = 76.43 KN-MET, LOADING 6
STAAD SPACE -- PAGE NO. 153

___ 9J____________________ 2500X 250X 300_____________________ 119J____


| |
| |
| |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 191 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 4 - 12MM 0. 2500. YES YES

B E A M N O. 191 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 19.70 KNS Tu= 16.8 KN-MET


Vc= 51.7 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 19.70 KNS Tu= 16.8 KN-MET
Vc= 51.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
STAAD SPACE -- PAGE NO. 154

___ 120J____________________ 2499X 250X 300_____________________ 23J____


| |
||=========================================================================||
| 4No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oooo | | oooo | | oooo | | oooo | | oooo |
| 4#12 | | 4#12 | | 4#12 | | 4#12 | | 4#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 192 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES

*** A SUITABLE BAR ARRANGEMENT COULD NOT BE DETERMINED.


REQD. STEEL = 1031. MM2, MAX. STEEL PERMISSIBLE = 1251. MM2
MAX NEG MOMENT = 76.43 KN-MET, LOADING 6
STAAD SPACE -- PAGE NO. 155

___ 8J____________________ 2500X 250X 300_____________________ 120J____


| |
| |
| |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 193 DESIGN RESULTS


=============================================

LEN - 12500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 12500. YES YES


2 243. 2 - 12MM 0. 12500. YES YES

B E A M N O. 193 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.05 KNS Vc= 95.81 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.8 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 0.05 KNS Vc= 95.81 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.8 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 156

___ 95J____________________ 12500X 250X 300_____________________ 86J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO12500 |
| |
| 2No12 H 57. 0.TO12500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 194 DESIGN RESULTS


=============================================

LEN - 12500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 2 - 12MM 0. 12500. YES YES


2 243. 2 - 12MM 0. 12500. YES YES

B E A M N O. 194 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 0.05 KNS Vc= 95.36 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.8 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
AT END SUPPORT - Vu= 0.05 KNS Vc= 95.36 KNS Vs= 0.00 KNS
Tu= 0.01 KN-MET Tc= 1.8 KN-MET Ts= 0.0 KN-MET LOAD 1
STIRRUPS ARE NOT REQUIRED.
STAAD SPACE -- PAGE NO. 157

___ 87J____________________ 12500X 250X 300_____________________ 96J____


| |
||=========================================================================||
| 2No12 H 243. 0.TO12500 |
| |
| 2No12 H 57. 0.TO12500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| oo | | oo | | oo | | oo | | oo |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| | | | | | | | | |
| 2#12 | | 2#12 | | 2#12 | | 2#12 | | 2#12 |
| oo | | oo | | oo | | oo | | oo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 195 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 3 - 12MM 0. 2500. YES YES

B E A M N O. 195 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 19.10 KNS Vc= 52.16 KNS Vs= 0.00 KNS
Tu= 8.62 KN-MET Tc= 1.6 KN-MET Ts= 11.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.55 SQ.CM.

AT END SUPPORT - Vu= 19.10 KNS Vc= 52.16 KNS Vs= 0.00 KNS
Tu= 8.62 KN-MET Tc= 1.6 KN-MET Ts= 11.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1013. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.55 SQ.CM.
STAAD SPACE -- PAGE NO. 158

___ 121J____________________ 2499X 250X 300_____________________ 91J____


| |
||=========================================================================||
| 3No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 196 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 3 - 12MM 0. 2500. YES YES

B E A M N O. 196 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 18.02 KNS Vc= 52.16 KNS Vs= 0.00 KNS
Tu= 8.62 KN-MET Tc= 1.6 KN-MET Ts= 11.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.55 SQ.CM.

AT END SUPPORT - Vu= 18.02 KNS Vc= 52.16 KNS Vs= 0.00 KNS
Tu= 8.62 KN-MET Tc= 1.6 KN-MET Ts= 11.5 KN-MET LOAD 6
STIRRUPS ARE REQUIRED FOR TORSION.
REINFORCEMENT FOR SHEAR IS PER CL.11.5.5.1.
PROVIDE 12 MM 2-LEGGED STIRRUPS AT 93. MM C/C FOR 1014. MM
ADDITIONAL LONGITUDINAL STEEL REQD. FOR TORSIONAL RESISTANCE = 3.55 SQ.CM.
STAAD SPACE -- PAGE NO. 159

___ 122J____________________ 2500X 250X 300_____________________ 90J____


| |
||=========================================================================||
| 3No12 H 243.| 0.TO 2500| | | | | | | | | | | | | | | | |
| 12*12c/c 93 | | | | | | | | | | | | | | | 12*12c/c 93 | |
| 3No12 H 57.| 0.TO 2500| | | | | | | | | | | | | | | | |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 197 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 3 - 12MM 0. 2500. YES YES

B E A M N O. 197 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 18.28 KNS Tu= 16.1 KN-MET


Vc= 52.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 18.28 KNS Tu= 16.1 KN-MET
Vc= 52.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
STAAD SPACE -- PAGE NO. 160

___ 123J____________________ 2499X 250X 300_____________________ 93J____


| |
||=========================================================================||
| 3No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

ACI 318-11 BEAM NO. 198 DESIGN RESULTS


=============================================

LEN - 2500. MM FY - 415. FC - 28. MPA, SIZE - 250. X 300. MMS

LEVEL HEIGHT BAR INFO FROM TO ANCHOR


(MM) (MM) (MM) STA END
_____________________________________________________________________

1 57. 3 - 12MM 0. 2500. YES YES


2 243. 3 - 12MM 0. 2500. YES YES

B E A M N O. 198 D E S I G N R E S U L T S - SHEAR

AT START SUPPORT - Vu= 18.84 KNS Tu= 16.1 KN-MET


Vc= 52.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
AT END SUPPORT - Vu= 18.84 KNS Tu= 16.1 KN-MET
Vc= 52.9 KNS, ACI 318:CLAUSE 11.6.3.1
LOAD 6 TORSION VALUE TOO HIGH, INCREASE MEMBER SIZE.
STAAD SPACE -- PAGE NO. 161

___ 124J____________________ 2500X 250X 300_____________________ 92J____


| |
||=========================================================================||
| 3No12 H 243. 0.TO 2500 |
| |
| 3No12 H 57. 0.TO 2500 |
||=========================================================================||
| |
|___________________________________________________________________________|
___________ ___________ ___________ ___________ ___________
| | | | | | | | | |
| ooo | | ooo | | ooo | | ooo | | ooo |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| | | | | | | | | |
| 3#12 | | 3#12 | | 3#12 | | 3#12 | | 3#12 |
| ooo | | ooo | | ooo | | ooo | | ooo |
| | | | | | | | | |
|___________| |___________| |___________| |___________| |___________|

********************END OF BEAM DESIGN**************************

207. DESIGN COLUMN 31 TO 86 115 TO 126


STAAD SPACE -- PAGE NO. 162

ACI 318-11 COLUMN NO. 31 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 32 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 33 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM
STAAD SPACE -- PAGE NO. 163

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 34 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 35 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 36 DESIGN RESULTS


===============================================
STAAD SPACE -- PAGE NO. 164

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 37 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 38 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM
STAAD SPACE -- PAGE NO. 165

ACI 318-11 COLUMN NO. 39 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 40 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 41 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM
STAAD SPACE -- PAGE NO. 166

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 42 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 43 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 44 DESIGN RESULTS


===============================================
STAAD SPACE -- PAGE NO. 167

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 45 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 46 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM
STAAD SPACE -- PAGE NO. 168

ACI 318-11 COLUMN NO. 47 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 48 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 49 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM
STAAD SPACE -- PAGE NO. 169

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 50 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 51 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 52 DESIGN RESULTS


===============================================
STAAD SPACE -- PAGE NO. 170

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 53 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 54 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM
STAAD SPACE -- PAGE NO. 171

ACI 318-11 COLUMN NO. 55 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 56 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 57 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM
STAAD SPACE -- PAGE NO. 172

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 58 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 59 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 60 DESIGN RESULTS


===============================================
STAAD SPACE -- PAGE NO. 173

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 61 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 62 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM
STAAD SPACE -- PAGE NO. 174

ACI 318-11 COLUMN NO. 63 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 64 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 65 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM
STAAD SPACE -- PAGE NO. 175

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 66 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 67 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 68 DESIGN RESULTS


===============================================
STAAD SPACE -- PAGE NO. 176

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 69 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 70 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM
STAAD SPACE -- PAGE NO. 177

ACI 318-11 COLUMN NO. 71 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 72 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 73 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM
STAAD SPACE -- PAGE NO. 178

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 74 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 75 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 76 DESIGN RESULTS


===============================================
STAAD SPACE -- PAGE NO. 179

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 77 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 78 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM
STAAD SPACE -- PAGE NO. 180

ACI 318-11 COLUMN NO. 79 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 80 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 81 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM
STAAD SPACE -- PAGE NO. 181

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 82 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 83 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 84 DESIGN RESULTS


===============================================
STAAD SPACE -- PAGE NO. 182

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 85 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 86 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM
STAAD SPACE -- PAGE NO. 183

ACI 318-11 COLUMN NO. 115 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 116 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.900


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 117 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM
STAAD SPACE -- PAGE NO. 184

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.900


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 118 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 119 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 120 DESIGN RESULTS


===============================================
STAAD SPACE -- PAGE NO. 185

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 121 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


AREA OF STEEL REQUIRED = 2645.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

24 - 12 MM 1.086 6 STA 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 192.00 MM

ACI 318-11 COLUMN NO. 122 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


AREA OF STEEL REQUIRED = 2645.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

24 - 12 MM 1.086 6 STA 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 192.00 MM
STAAD SPACE -- PAGE NO. 186

ACI 318-11 COLUMN NO. 123 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.900


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 124 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.900


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

ACI 318-11 COLUMN NO. 125 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.900


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM
STAAD SPACE -- PAGE NO. 187

ACI 318-11 COLUMN NO. 126 DESIGN RESULTS


===============================================

FY - 415.0 FC - 27.6 MPA, SQRE SIZE - 500.0 X 500.0 MMS, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 2500.0 SQ. MM

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - 20 MM 1.005 1 END 0.900


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 12 SPACING 320.00 MM

********************END OF COLUMN DESIGN RESULTS********************

208. END CONCRETE DESIGN


209. PRINT MAXFORCE ENVELOPE LIST ALL
STAAD SPACE -- PAGE NO. 188

MEMBER FORCE ENVELOPE


---------------------

ALL UNITS ARE KN METE

MAX AND MIN FORCE VALUES AMONGST ALL SECTION LOCATIONS

MEMB FY/ DIST LD MZ/ DIST LD


FZ DIST LD MY DIST LD FX DIST LD

1 MAX 55.31 0.00 1 52.13 0.00 1


4.60 0.00 6 6.66 2.50 6 3.63 C 0.00 6
MIN -0.10 2.50 6 -37.63 2.50 1
-0.15 2.50 2 -4.85 0.00 6 14.31 T 2.50 1

2 MAX 38.95 0.00 1 32.86 0.00 1


0.04 0.00 3 0.75 0.00 1 6.90 C 0.00 6
MIN -38.64 5.00 1 -16.03 2.50 1
-0.24 5.00 1 -0.65 5.00 6 7.17 T 5.00 1

3 MAX 38.63 0.00 1 32.86 5.00 1


0.24 0.00 1 0.73 5.00 1 6.90 C 0.00 6
MIN -38.96 5.00 1 -16.05 2.50 1
-0.03 5.00 3 -0.65 0.00 6 7.18 T 5.00 1

4 MAX 54.52 0.00 1 51.82 0.00 1


0.29 0.00 1 1.01 2.50 6 6.97 C 0.00 6
MIN -0.06 2.50 6 -35.97 2.50 1
-0.10 2.50 2 -0.58 0.00 1 13.89 T 2.50 1

5 MAX 38.60 0.00 1 32.58 5.00 1


0.14 0.00 1 7.19 0.00 6 5.51 C 0.00 6
MIN -39.00 5.00 1 -16.42 2.50 1
-3.74 5.00 6 -11.52 5.00 6 9.02 T 5.00 1

6 MAX 38.59 0.00 1 32.62 5.00 1


3.74 0.00 6 11.52 5.00 6 5.51 C 0.00 6
MIN -39.02 5.00 1 -16.41 2.50 1
-0.14 5.00 1 -7.19 0.00 6 8.93 T 5.00 1

7 MAX 38.91 0.00 1 32.60 0.00 1


9.58 0.00 6 25.13 5.00 6 0.45 C 0.00 2
MIN -38.70 5.00 1 -16.17 2.50 1
-0.23 5.00 1 -22.77 0.00 6 12.11 T 5.00 6

8 MAX 38.89 0.00 1 32.55 0.00 1


0.23 0.00 1 22.77 0.00 6 0.50 C 0.00 2
MIN -38.72 5.00 1 -16.17 2.50 1
-9.58 5.00 6 -25.13 5.00 6 12.11 T 5.00 6

11 MAX 43.46 0.00 1 38.31 0.00 1


4.23 0.00 6 0.82 0.00 1 0.32 C 0.00 3
STAAD SPACE -- PAGE NO. 189

MIN -0.11 2.50 5 -21.83 2.50 1


-0.18 2.50 1 -21.65 0.00 6 18.42 T 2.50 6

12 MAX 43.44 0.00 1 38.26 0.00 1


0.16 0.00 1 21.65 0.00 6 0.48 C 0.00 2
MIN -1.90 2.50 3 -21.83 2.50 1
-4.23 2.50 6 -0.76 0.00 1 18.42 T 2.50 6

13 MAX 41.91 0.00 1 35.64 0.00 1


0.67 0.00 6 0.26 0.00 1 0.23 C 0.00 3
MIN -1.85 2.50 2 -20.64 2.50 1
-0.18 2.50 1 -2.10 0.00 6 8.32 T 2.50 1

14 MAX 38.82 0.00 1 32.44 0.00 1


0.13 0.00 1 0.87 0.00 6 5.26 C 0.00 6
MIN -38.75 5.00 1 -16.14 2.50 1
-0.23 5.00 6 -0.39 0.00 1 6.06 T 5.00 1

15 MAX 38.73 0.00 1 32.47 5.00 1


0.23 0.00 6 0.87 5.00 6 5.26 C 0.00 6
MIN -38.84 5.00 1 -16.14 2.50 1
-0.13 5.00 1 -0.39 5.00 1 6.06 T 5.00 1

16 MAX 41.95 0.00 1 36.33 0.00 1


0.97 0.00 6 2.34 2.50 6 4.98 C 0.00 6
MIN -1.72 2.50 2 -20.08 2.50 1
-0.08 2.50 2 -0.08 0.00 3 8.02 T 2.50 1

17 MAX 16.39 0.00 1 8.55 2.50 1


0.99 0.00 1 22.24 0.00 6 0.17 C 0.00 3
MIN -18.14 2.50 1 -3.33 1.25 1
-17.94 2.50 6 -22.61 2.50 6 14.41 T 2.50 6

18 MAX 34.19 0.00 1 29.53 5.00 1


0.05 0.00 5 8.32 0.00 6 0.44 C 0.00 2
MIN -34.87 5.00 1 -14.49 2.50 1
-1.65 5.00 6 -0.65 5.00 1 3.40 T 5.00 1

19 MAX 42.77 0.00 1 38.86 0.00 1


1.42 0.00 6 1.14 0.00 5 0.55 C 0.00 3
MIN -0.15 2.50 4 -24.90 2.50 1
-0.88 2.50 5 -4.62 0.00 6 4.57 T 2.50 1

20 MAX 34.84 0.00 1 29.44 0.00 1


1.65 0.00 6 8.32 5.00 6 0.47 C 0.00 3
MIN -34.22 5.00 1 -14.49 2.50 1
-0.02 5.00 5 -0.62 0.00 1 3.38 T 5.00 1

21 MAX 18.04 0.00 1 8.43 0.00 1


17.94 0.00 6 22.24 2.50 6 0.17 C 0.00 2
MIN -16.49 2.50 1 -3.33 1.25 1
-0.94 2.50 1 -22.61 0.00 6 14.41 T 2.50 6

22 MAX 22.17 0.00 1 11.22 0.00 1


0.19 0.00 1 0.95 0.00 6 10.89 C 0.00 6
STAAD SPACE -- PAGE NO. 190

MIN -20.36 2.50 1 -3.20 1.25 1


-16.37 2.50 6 -39.98 2.50 6 0.23 T 2.50 3

23 MAX 20.31 0.00 1 10.25 0.00 1


16.37 0.00 6 39.98 2.50 6 10.89 C 0.00 6
MIN -18.78 2.50 1 -2.93 1.25 1
-0.17 2.50 1 -0.95 0.00 6 0.23 T 2.50 2

24 MAX 44.07 0.00 1 37.09 0.00 1


0.93 0.00 1 29.74 0.00 6 15.57 C 0.00 6
MIN -20.84 2.50 6 -26.52 0.00 6
-6.07 2.50 6 -1.91 0.00 1 0.51 T 2.50 1

25 MAX 40.86 0.00 1 34.52 0.00 1


6.07 0.00 6 1.83 0.00 1 15.57 C 0.00 6
MIN -20.84 2.50 6 -26.52 0.00 6
-0.89 2.50 1 -29.74 0.00 6 0.77 T 2.50 5

26 MAX 42.93 0.00 1 36.41 0.00 1


0.08 0.00 1 8.09 0.00 6 18.52 C 0.00 6
MIN -42.13 5.00 1 -17.75 2.50 1
-4.18 5.00 6 -12.82 5.00 6 0.98 T 5.00 1

27 MAX 39.45 0.00 1 33.46 0.00 1


4.18 0.00 6 12.82 5.00 6 18.52 C 0.00 6
MIN -38.73 5.00 1 -16.30 2.50 1
-0.08 5.00 1 -8.09 0.00 6 0.82 T 5.00 1

28 MAX 46.58 0.00 1 39.11 5.00 1


1.43 0.00 6 0.55 5.00 1 1.10 C 0.00 5
MIN -46.79 5.00 1 -19.51 2.50 1
0.00 5.00 4 -7.58 0.00 6 4.47 T 5.00 6

29 MAX 46.90 0.00 1 39.15 0.00 1


0.24 0.00 1 4.51 0.00 6 0.18 C 0.00 3
MIN -3.20 2.50 3 -19.75 2.50 1
-1.33 2.50 6 -0.57 0.00 1 4.42 T 2.50 6

30 MAX 46.77 0.00 1 39.06 0.00 1


0.04 0.00 4 0.54 0.00 1 1.07 C 0.00 4
MIN -46.60 5.00 1 -19.51 2.50 1
-1.43 5.00 6 -7.58 5.00 6 4.47 T 5.00 6

31 MAX 0.57 0.00 4 1.72 0.00 4


4.65 0.00 1 1.12 0.00 5 186.49 C 0.00 1
MIN -6.34 3.00 1 -19.01 0.00 1
-0.37 3.00 5 -13.96 0.00 1 1.79 C 3.00 6

32 MAX 1.74 0.00 1 5.22 0.00 1


1.32 0.00 1 0.53 0.00 6 190.56 C 0.00 1
MIN -0.71 3.00 4 -2.14 0.00 4
-0.18 3.00 6 -3.97 0.00 1 0.12 T 3.00 6

33 MAX 0.80 0.00 3 2.41 0.00 3


6.37 0.00 1 0.00 3.00 1 204.42 C 0.00 1
STAAD SPACE -- PAGE NO. 191

MIN -0.80 3.00 2 -2.41 0.00 2


0.20 3.00 4 -19.12 0.00 1 0.01 C 3.00 6

34 MAX 0.28 0.00 4 0.85 0.00 4


1.21 0.00 1 0.53 0.00 6 187.67 C 0.00 1
MIN -1.54 3.00 1 -4.62 0.00 1
-0.18 3.00 6 -3.62 0.00 1 0.12 T 3.00 6

35 MAX 6.15 0.00 1 18.46 0.00 1


4.58 0.00 1 1.15 0.00 5 183.69 C 0.00 1
MIN -0.53 3.00 4 -1.59 0.00 4
-0.38 3.00 5 -13.73 0.00 1 1.79 C 3.00 6

36 MAX 1.83 0.00 6 5.49 0.00 6


1.75 0.00 6 3.56 0.00 3 188.84 C 0.00 1
MIN -1.03 3.00 1 -3.08 0.00 1
-1.19 3.00 3 -5.25 0.00 6 4.13 C 3.00 6

37 MAX 1.06 0.00 1 3.18 0.00 1


1.75 0.00 6 3.55 0.00 3 188.97 C 0.00 1
MIN -1.83 3.00 6 -5.49 0.00 6
-1.18 3.00 3 -5.25 0.00 6 4.13 C 3.00 6

38 MAX -0.12 0.00 5 0.00 3.00 1


1.53 0.00 6 2.01 0.00 2 199.58 C 0.00 1
MIN -23.07 3.00 6 -69.22 0.00 6
-0.67 3.00 2 -4.58 0.00 6 7.54 C 3.00 5

39 MAX 23.07 0.00 6 69.22 0.00 6


1.53 0.00 6 2.10 0.00 2 198.63 C 0.00 1
MIN 0.10 3.00 4 0.00 3.00 6
-0.70 3.00 2 -4.58 0.00 6 7.56 C 3.00 4

40 MAX 0.64 0.00 1 1.93 0.00 1


1.55 0.00 6 0.30 0.00 4 164.83 C 0.00 1
MIN -3.77 3.00 6 -11.30 0.00 6
-0.10 3.00 4 -4.66 0.00 6 0.95 C 3.00 4

41 MAX 3.77 0.00 6 11.30 0.00 6


1.55 0.00 6 1.90 0.00 3 164.82 C 0.00 1
MIN -0.64 3.00 1 -1.91 0.00 1
-0.63 3.00 3 -4.66 0.00 6 2.12 C 3.00 6

42 MAX 0.25 0.00 5 0.75 0.00 5


1.05 0.00 6 12.26 0.00 1 167.59 C 0.00 1
MIN -4.15 3.00 1 -12.44 0.00 1
-4.09 3.00 1 -3.16 0.00 6 1.47 C 3.00 6

43 MAX 4.09 0.00 1 12.27 0.00 1


1.05 0.00 6 12.33 0.00 1 166.61 C 0.00 1
MIN -0.27 3.00 5 -0.80 0.00 5
-4.11 3.00 1 -3.16 0.00 6 1.47 C 3.00 6

44 MAX 0.30 0.00 2 0.89 0.00 2


0.48 0.00 1 2.13 0.00 6 163.03 C 0.00 1
STAAD SPACE -- PAGE NO. 192

MIN -0.18 3.00 4 -0.54 0.00 4


-0.71 3.00 6 -1.43 0.00 1 0.62 C 3.00 2

45 MAX 0.78 0.00 3 2.34 0.00 3


-0.40 0.00 5 15.19 0.00 1 194.73 C 0.00 1
MIN -0.78 3.00 2 -2.33 0.00 2
-5.06 3.00 1 0.00 3.00 6 3.46 C 3.00 6

46 MAX 0.50 0.00 2 1.49 0.00 2


0.48 0.00 1 2.13 0.00 6 161.91 C 0.00 1
MIN -0.79 3.00 3 -2.38 0.00 3
-0.71 3.00 6 -1.43 0.00 1 0.85 C 3.00 6

47 MAX 1.84 0.00 6 5.53 0.00 6


0.28 0.00 4 17.50 0.00 1 252.52 C 0.00 1
MIN -3.02 3.00 1 -9.07 0.00 1
-5.83 3.00 1 -0.84 0.00 4 8.86 C 3.00 5

48 MAX 1.24 0.00 2 3.71 0.00 2


14.89 0.00 1 7.80 0.00 4 258.57 C 0.00 1
MIN -2.57 3.00 3 -7.72 0.00 3
-2.60 3.00 4 -44.67 0.00 1 1.35 T 3.00 6

49 MAX 1.44 0.00 1 4.33 0.00 1


12.56 0.00 3 7.59 0.00 5 241.35 C 0.00 1
MIN -0.25 3.00 6 -0.74 0.00 6
-2.53 3.00 5 -37.69 0.00 3 1.35 T 3.00 6

50 MAX 3.07 0.00 1 9.20 0.00 1


0.28 0.00 4 16.26 0.00 1 240.54 C 0.00 1
MIN -1.84 3.00 6 -5.53 0.00 6
-5.42 3.00 1 -0.85 0.00 4 12.28 C 3.00 5

51 MAX 0.87 0.00 6 2.60 0.00 6


3.57 0.00 1 13.21 0.00 6 129.91 C 0.00 1
MIN -0.48 3.00 1 -1.44 0.00 1
-4.40 3.00 6 -10.71 0.00 1 3.15 C 3.00 2

52 MAX 0.45 0.00 1 1.36 0.00 1


3.33 0.00 1 13.21 0.00 6 120.36 C 0.00 1
MIN -0.87 3.00 6 -2.60 0.00 6
-4.40 3.00 6 -9.98 0.00 1 0.63 C 3.00 2

53 MAX 19.39 0.00 6 58.18 0.00 6


2.40 0.00 6 2.20 0.00 3 174.46 C 0.00 1
MIN -0.64 3.00 1 -1.93 0.00 1
-0.73 3.00 3 -7.19 0.00 6 2.10 C 3.00 5

54 MAX 0.60 0.00 1 1.79 0.00 1


2.40 0.00 6 3.27 0.00 3 161.13 C 0.00 1
MIN -19.39 3.00 6 -58.18 0.00 6
-1.09 3.00 3 -7.19 0.00 6 4.07 C 3.00 3

55 MAX 1.43 0.00 6 4.30 0.00 6


0.79 0.00 3 4.00 0.00 2 325.45 C 0.00 1
STAAD SPACE -- PAGE NO. 193

MIN -1.50 3.00 2 -4.51 0.00 2


-1.33 3.00 2 -2.38 0.00 3 18.17 C 3.00 5

56 MAX 1.52 0.00 3 4.57 0.00 3


0.63 0.00 3 3.54 0.00 6 313.98 C 0.00 1
MIN -1.43 3.00 6 -4.30 0.00 6
-1.18 3.00 6 -1.89 0.00 3 21.39 C 3.00 4

57 MAX 0.81 0.00 2 2.43 0.00 2


2.56 0.00 4 47.28 0.00 1 290.84 C 0.00 1
MIN -1.23 3.00 3 -3.69 0.00 3
-15.76 3.00 1 -7.67 0.00 4 2.60 T 3.00 6

58 MAX 1.86 0.00 2 5.59 0.00 2


2.51 0.00 5 40.12 0.00 3 273.64 C 0.00 1
MIN -1.44 3.00 3 -4.31 0.00 3
-13.37 3.00 3 -7.52 0.00 5 2.60 T 3.00 6

59 MAX 0.02 0.00 6 49.10 4.00 1


-0.26 0.00 2 22.00 0.00 1 92.59 C 0.00 1
MIN -20.51 4.00 1 -32.94 0.00 1
-13.86 4.00 1 -33.44 4.00 1 0.07 T 4.00 3

60 MAX 8.97 0.00 1 15.55 0.00 1


0.12 0.00 6 0.72 0.00 1 95.65 C 0.00 1
MIN -0.43 4.00 5 -20.34 4.00 1
-1.39 4.00 1 -4.85 4.00 1 0.06 T 4.00 3

61 MAX 0.50 0.00 3 3.98 4.00 4


0.94 0.00 6 8.63 0.00 3 101.70 C 0.00 1
MIN -1.18 4.00 4 -2.02 0.00 2
-7.85 4.00 1 -23.84 4.00 1 0.07 T 4.00 3

62 MAX 0.44 0.00 5 18.67 4.00 1


0.12 0.00 6 0.61 0.00 1 94.19 C 0.00 1
MIN -8.25 4.00 1 -14.34 0.00 1
-1.26 4.00 1 -4.41 4.00 1 0.06 T 4.00 2

63 MAX 19.81 0.00 1 31.79 0.00 1


-0.24 0.00 2 21.72 0.00 1 91.19 C 0.00 1
MIN -0.02 4.00 6 -47.46 4.00 1
-13.68 4.00 1 -32.98 4.00 1 0.16 T 4.00 3

64 MAX 0.74 0.00 6 6.78 4.00 1


1.80 0.00 5 5.35 4.00 5 94.54 C 0.00 1
MIN -2.66 4.00 1 -3.86 0.00 1
-1.59 4.00 4 -4.88 4.00 4 0.04 C 4.00 3

65 MAX 2.67 0.00 1 3.87 0.00 1


1.80 0.00 5 5.38 4.00 5 94.57 C 0.00 1
MIN -0.74 4.00 6 -6.79 4.00 1
-1.60 4.00 4 -4.90 4.00 4 0.06 C 4.00 2

66 MAX -0.25 0.00 3 76.88 4.00 6


1.26 0.00 4 4.13 4.00 4 99.25 C 0.00 1
STAAD SPACE -- PAGE NO. 194

MIN -24.32 4.00 6 -20.41 0.00 6


-1.23 4.00 5 -4.07 4.00 5 0.17 T 4.00 2

67 MAX 24.32 0.00 6 20.41 0.00 6


1.29 0.00 4 4.25 4.00 4 98.79 C 0.00 1
MIN 0.21 4.00 2 -76.88 4.00 6
-1.25 4.00 5 -4.15 4.00 5 0.12 T 4.00 3

68 MAX 3.51 0.00 6 13.02 0.00 6


0.07 0.00 3 4.77 0.00 1 82.62 C 0.00 1
MIN -0.01 4.00 2 -1.67 4.00 1
-2.74 4.00 1 -6.18 4.00 1 0.06 T 4.00 3

69 MAX -0.00 0.00 2 1.69 4.00 1


0.88 0.00 5 4.76 0.00 1 82.61 C 0.00 1
MIN -3.51 4.00 6 -13.02 0.00 6
-2.72 4.00 1 -6.11 4.00 1 0.05 T 4.00 3

70 MAX 0.03 0.00 6 30.63 4.00 1


13.21 0.00 1 31.39 4.00 1 83.11 C 0.00 1
MIN -12.82 4.00 1 -20.66 0.00 1
0.24 4.00 6 -21.47 0.00 1 0.21 T 4.00 2

71 MAX 12.56 0.00 1 20.21 0.00 1


13.23 0.00 1 31.44 4.00 1 82.61 C 0.00 1
MIN -0.03 4.00 6 -30.03 4.00 1
0.19 4.00 3 -21.48 0.00 1 0.07 T 4.00 2

72 MAX 2.29 0.00 1 4.21 0.00 1


0.00 0.00 5 1.16 0.00 6 81.69 C 0.00 1
MIN 0.07 4.00 3 -4.93 4.00 1
-0.66 4.00 1 -1.85 4.00 1 0.00 T 4.00 2

73 MAX 1.20 0.00 5 4.01 4.00 4


5.83 0.00 1 17.62 4.00 1 96.74 C 0.00 1
MIN -1.20 4.00 4 -4.01 4.00 5
-0.34 4.00 6 -5.69 0.00 1 0.15 T 4.00 2

74 MAX 0.80 0.00 4 4.25 4.00 1


-0.00 0.00 2 1.16 0.00 6 81.12 C 0.00 1
MIN -2.00 4.00 1 -3.74 0.00 1
-0.65 4.00 1 -1.84 4.00 1 0.09 T 4.00 2

75 MAX 0.89 0.00 6 10.05 4.00 1


11.86 0.00 1 24.23 4.00 1 126.63 C 0.00 1
MIN -5.06 4.00 1 -10.21 0.00 1
0.01 4.00 5 -23.20 0.00 1 0.41 T 4.00 3

76 MAX 1.07 0.00 2 5.48 4.00 5


0.64 0.00 5 58.94 0.00 1 129.36 C 0.00 1
MIN -2.57 4.00 1 -6.75 0.00 3
-29.33 4.00 1 -58.36 4.00 1 1.05 T 4.00 6

77 MAX 2.65 0.00 1 5.23 0.00 1


0.23 0.00 6 48.93 0.00 1 120.78 C 0.00 1
STAAD SPACE -- PAGE NO. 195

MIN 0.11 4.00 3 -5.36 4.00 1


-24.30 4.00 1 -48.27 4.00 1 1.05 T 4.00 6

78 MAX 5.12 0.00 1 10.29 0.00 1


11.05 0.00 1 22.58 4.00 1 120.63 C 0.00 1
MIN -0.89 4.00 6 -10.20 4.00 1
-0.01 4.00 5 -21.61 0.00 1 0.47 T 4.00 3

79 MAX 11.17 0.00 6 0.34 0.00 4


9.08 0.00 6 21.18 4.00 6 65.48 C 0.00 1
MIN -0.02 4.00 3 -63.63 4.00 6
-8.49 4.00 1 -16.55 4.00 1 0.06 T 4.00 2

80 MAX 0.03 0.00 2 63.63 4.00 6


9.08 0.00 6 21.18 4.00 6 60.72 C 0.00 1
MIN -11.17 4.00 6 -0.40 0.00 5
-7.90 4.00 1 -15.40 4.00 1 0.13 T 4.00 2

81 MAX 9.91 0.00 6 0.55 0.00 4


0.68 0.00 3 13.84 0.00 6 87.48 C 0.00 1
MIN -0.02 4.00 3 -123.13 4.00 6
-6.22 4.00 6 -11.05 4.00 6 0.01 T 4.00 2

82 MAX 0.00 0.00 2 123.13 4.00 6


0.98 0.00 3 13.84 0.00 6 80.82 C 0.00 1
MIN -9.91 4.00 6 -0.51 0.00 5
-6.22 4.00 6 -11.05 4.00 6 0.05 T 4.00 2

83 MAX 1.85 0.00 6 3.93 4.00 4


1.00 0.00 2 3.92 4.00 4 162.82 C 0.00 1
MIN -1.63 4.00 1 -5.44 4.00 6
-0.68 4.00 6 -4.07 0.00 2 0.16 T 4.00 2

84 MAX 1.65 0.00 1 5.44 4.00 6


0.84 0.00 4 3.41 4.00 4 157.10 C 0.00 1
MIN -1.85 4.00 6 -3.99 4.00 5
-0.68 4.00 6 -3.33 0.00 2 0.09 T 4.00 3

85 MAX 0.68 0.00 2 3.18 4.00 5


30.47 0.00 1 61.62 4.00 1 145.67 C 0.00 1
MIN -1.02 4.00 5 -2.95 0.00 3
0.17 4.00 3 -60.24 0.00 1 1.51 T 4.00 6

86 MAX 1.61 0.00 4 4.67 0.00 2


25.44 0.00 1 51.52 4.00 1 137.10 C 0.00 1
MIN -1.26 4.00 3 -4.92 4.00 4
-0.14 4.00 4 -50.23 0.00 1 1.51 T 4.00 6

87 MAX 41.18 0.00 1 33.69 0.00 1


1.39 0.00 6 0.27 0.00 1 12.80 C 0.00 1
MIN -1.84 2.50 4 -20.78 2.50 1
-0.19 2.50 1 -4.81 0.00 6 1.67 T 2.50 6

88 MAX 38.88 0.00 1 32.60 0.00 1


0.01 0.00 5 1.51 0.00 6 14.07 C 0.00 6
STAAD SPACE -- PAGE NO. 196

MIN -38.69 5.00 1 -16.11 2.50 1


-0.45 5.00 6 -0.97 5.00 1 0.09 C 5.00 4

89 MAX 38.70 0.00 1 32.59 5.00 1


0.45 0.00 6 1.51 5.00 6 14.07 C 0.00 6
MIN -38.87 5.00 1 -16.12 2.50 1
-0.03 5.00 3 -0.99 0.00 1 0.27 T 5.00 5

90 MAX 42.25 0.00 1 36.84 0.00 1


0.42 0.00 6 3.51 2.50 6 14.37 C 0.00 6
MIN -1.64 2.50 4 -20.31 2.50 1
-0.29 2.50 1 -0.31 2.50 1 0.32 C 2.50 3

91 MAX 41.95 0.00 1 34.56 0.00 1


1.64 0.00 6 0.52 2.50 6 13.36 C 0.00 1
MIN -0.09 2.50 2 -21.82 2.50 1
-0.10 2.50 2 -3.58 0.00 6 1.14 T 2.50 6

92 MAX 38.87 0.00 1 32.58 0.00 1


13.08 0.00 6 44.03 5.00 6 11.71 C 0.00 1
MIN -38.73 5.00 1 -16.10 2.50 1
-0.78 5.00 1 -21.38 0.00 6 43.03 T 5.00 6

93 MAX 38.75 0.00 1 32.46 5.00 1


1.02 0.00 1 64.52 0.00 6 11.67 C 0.00 1
MIN -38.85 5.00 1 -16.18 2.50 1
-24.99 5.00 6 -60.41 5.00 6 20.04 T 5.00 6

94 MAX 39.61 0.00 1 33.64 0.00 1


4.81 0.00 6 9.13 5.00 6 12.17 C 0.00 1
MIN -37.99 5.00 1 -16.88 2.50 1
-0.38 5.00 1 -14.89 0.00 6 0.10 C 5.00 2

95 MAX 53.20 0.00 1 47.96 0.00 1


1.51 0.00 1 11.48 0.00 6 19.43 C 0.00 1
MIN -0.05 2.50 3 -36.53 2.50 1
-10.16 2.50 6 -13.91 2.50 6 0.28 C 2.50 3

96 MAX 39.19 0.00 1 33.62 0.00 1


0.45 0.00 6 1.51 5.00 6 12.20 C 0.00 6
MIN -38.41 5.00 1 -15.86 2.50 1
-0.17 5.00 5 -0.76 0.00 6 0.09 C 5.00 3

97 MAX 38.39 0.00 1 33.69 5.00 1


0.16 0.00 5 1.51 0.00 6 12.20 C 0.00 6
MIN -39.21 5.00 1 -15.83 2.50 1
-0.45 5.00 6 -0.76 5.00 6 0.07 T 5.00 2

98 MAX 56.44 0.00 1 54.04 0.00 1


1.47 0.00 1 2.20 2.50 1 19.93 C 0.00 1
MIN -1.16 2.50 5 -38.57 2.50 1
-0.57 2.50 6 -1.65 2.50 6 0.29 C 2.50 3

99 MAX 38.00 0.00 1 33.63 5.00 1


0.38 0.00 1 9.13 0.00 6 12.28 C 0.00 1
STAAD SPACE -- PAGE NO. 197

MIN -39.61 5.00 1 -16.89 2.50 1


-4.81 5.00 6 -14.89 5.00 6 0.02 T 5.00 2

100 MAX 38.87 0.00 1 32.50 0.00 1


24.99 0.00 6 64.52 5.00 6 11.80 C 0.00 1
MIN -38.74 5.00 1 -16.17 2.50 1
-1.06 5.00 1 -60.41 0.00 6 20.04 T 5.00 6

101 MAX 38.75 0.00 1 32.55 5.00 1


0.81 0.00 1 44.03 0.00 6 11.84 C 0.00 1
MIN -38.86 5.00 1 -16.10 2.50 1
-13.08 5.00 6 -21.38 5.00 6 43.03 T 5.00 6

102 MAX 43.76 0.00 1 38.73 0.00 1


0.37 0.00 1 2.00 0.00 6 14.58 C 0.00 1
MIN -0.12 2.50 3 -22.17 2.50 1
-16.60 2.50 6 -39.49 2.50 6 41.63 T 2.50 6

103 MAX 46.56 0.00 1 39.17 5.00 1


4.59 0.00 6 3.84 5.00 6 1.91 C 0.00 1
MIN -46.81 5.00 1 -19.50 2.50 1
-0.02 5.00 2 -19.13 0.00 6 50.67 T 5.00 6

104 MAX 47.47 0.00 1 39.84 0.00 1


0.62 0.00 6 4.62 2.50 6 1.82 C 0.00 1
MIN -3.07 2.50 5 -20.49 2.50 1
-2.54 2.50 1 -3.66 2.50 1 51.97 T 2.50 6

105 MAX 46.80 0.00 1 39.14 0.00 1


0.01 0.00 4 3.84 0.00 6 1.93 C 0.00 1
MIN -46.57 5.00 1 -19.50 2.50 1
-4.59 5.00 6 -19.13 5.00 6 50.67 T 5.00 6

106 MAX 38.57 0.00 1 33.86 5.00 1


23.94 0.00 6 59.67 5.00 6 27.56 C 0.00 6
MIN -39.60 5.00 1 -16.28 2.50 1
-0.43 5.00 1 -60.02 0.00 6 0.75 T 5.00 1

107 MAX 41.23 0.00 1 34.89 0.00 1


-0.10 0.00 2 84.99 0.00 6 24.90 C 0.00 6
MIN -19.96 2.50 6 -24.11 0.00 6
-47.99 2.50 6 -34.99 2.50 6 0.39 T 2.50 2

108 MAX 18.82 0.00 1 10.20 2.50 1


0.78 0.00 1 10.26 0.00 6 14.69 C 0.00 6
MIN -20.26 2.50 1 -2.91 1.25 1
-27.38 2.50 6 -58.19 2.50 6 3.24 T 2.50 1

109 MAX 34.22 0.00 1 29.46 5.00 1


5.29 0.00 6 4.98 5.00 6 6.99 C 0.00 1
MIN -34.84 5.00 1 -14.48 2.50 1
-0.02 5.00 3 -21.47 0.00 6 60.28 T 5.00 6

110 MAX 43.10 0.00 1 39.35 0.00 1


0.02 0.00 6 4.13 0.00 1 7.98 C 0.00 1
STAAD SPACE -- PAGE NO. 198

MIN -1.45 2.50 4 -25.25 2.50 1


-3.85 2.50 1 -5.49 2.50 1 60.94 T 2.50 6

111 MAX 34.87 0.00 1 29.52 0.00 1


0.05 0.00 2 4.98 0.00 6 6.98 C 0.00 1
MIN -34.19 5.00 1 -14.48 2.50 1
-5.29 5.00 6 -21.47 5.00 6 60.28 T 5.00 6

112 MAX 22.14 0.00 1 11.20 0.00 1


27.38 0.00 6 10.26 2.50 6 14.69 C 0.00 6
MIN -20.39 2.50 1 -3.19 1.25 1
-0.82 2.50 1 -58.19 0.00 6 3.47 T 2.50 1

113 MAX 44.70 0.00 1 38.02 0.00 1


-0.11 0.00 3 41.43 0.00 6 0.70 C 0.00 6
MIN -20.18 2.50 6 -24.98 0.00 6
-14.40 2.50 6 -3.72 2.50 1 0.03 C 2.50 2

114 MAX 43.09 0.00 1 36.83 0.00 1


0.46 0.00 1 59.67 0.00 6 27.56 C 0.00 6
MIN -41.97 5.00 1 -17.73 2.50 1
-23.94 5.00 6 -60.02 5.00 6 0.72 T 5.00 1

115 MAX 5.91 0.00 6 4.73 0.00 6


5.89 0.00 1 2.75 0.00 6 35.63 C 0.00 6
MIN -3.19 3.00 1 -13.00 3.00 6
-0.41 3.00 6 -16.89 0.00 1 0.29 T 3.00 5

116 MAX 0.75 0.00 4 2.07 0.00 4


2.75 0.00 2 45.11 0.00 1 0.03 C 0.00 5
MIN -2.29 3.00 5 -6.37 0.00 5
-15.41 3.00 1 -8.36 0.00 2 0.68 T 3.00 6

117 MAX 1.68 0.00 1 4.52 0.00 1


2.39 0.00 3 38.42 0.00 5 0.13 C 0.00 4
MIN -0.17 3.00 2 -1.29 3.00 6
-13.00 3.00 5 -6.91 0.00 3 0.68 T 3.00 6

118 MAX 3.20 0.00 1 13.00 3.00 6


5.51 0.00 1 2.75 0.00 6 35.63 C 0.00 6
MIN -5.91 3.00 6 -4.73 0.00 6
-0.41 3.00 6 -15.74 0.00 1 0.20 T 3.00 3

119 MAX -0.07 0.00 5 6.40 3.00 6


0.31 0.00 2 12.46 0.00 1 57.26 C 0.00 6
MIN -30.61 3.00 6 -85.44 0.00 6
-4.91 3.00 6 -17.67 3.00 6 0.21 T 3.00 4

120 MAX 30.61 0.00 6 85.44 0.00 6


0.24 0.00 3 11.60 0.00 1 57.26 C 0.00 6
MIN 0.04 3.00 2 -6.40 3.00 6
-4.91 3.00 6 -17.67 3.00 6 0.14 T 3.00 4

121 MAX -0.03 0.00 3 24.72 3.00 6


0.90 0.00 5 11.08 0.00 6 75.06 C 0.00 6
STAAD SPACE -- PAGE NO. 199

MIN -62.02 3.00 6 -161.34 0.00 6


-3.57 3.00 6 -2.04 3.00 1 0.10 T 3.00 4

122 MAX 62.02 0.00 6 161.34 0.00 6


1.32 0.00 5 11.08 0.00 6 75.06 C 0.00 6
MIN 0.06 3.00 4 -24.72 3.00 6
-3.57 3.00 6 -3.21 0.00 5 0.07 T 3.00 4

123 MAX 6.11 0.00 6 4.38 0.00 6


9.45 0.00 6 22.08 3.00 6 56.07 C 0.00 6
MIN -1.66 3.00 4 -13.95 3.00 6
-0.75 3.00 5 -6.28 0.00 6 0.43 T 3.00 1

124 MAX 1.71 0.00 5 13.95 3.00 6


9.45 0.00 6 22.08 3.00 6 56.07 C 0.00 6
MIN -6.11 3.00 6 -4.38 0.00 6
-0.71 3.00 5 -6.28 0.00 6 0.40 T 3.00 1

125 MAX 0.82 0.00 4 2.11 0.00 4


15.32 0.00 1 7.82 0.00 2 0.16 C 0.00 5
MIN -1.34 3.00 5 -3.55 0.00 5
-2.69 3.00 2 -45.62 0.00 1 0.61 T 3.00 6

126 MAX 2.01 0.00 4 5.45 0.00 4


12.94 0.00 5 7.75 0.00 3 0.10 C 0.00 4
MIN -1.48 3.00 5 -4.01 0.00 5
-2.54 3.00 3 -38.09 0.00 1 0.61 T 3.00 6

127 MAX 0.66 0.00 6 2.15 0.00 6


10.96 0.00 6 13.51 5.00 6 1.75 C 0.00 4
MIN -0.01 5.00 2 -1.17 5.00 6
-0.04 5.00 4 -41.28 0.00 6 134.23 T 5.00 6

128 MAX 0.16 0.00 5 0.43 5.00 4


0.04 0.00 4 4.71 3.75 6 1.75 C 0.00 1
MIN -0.16 5.00 4 -0.40 5.00 5
-0.04 5.00 5 -0.41 0.00 1 133.32 T 5.00 6

129 MAX 0.01 0.00 3 2.15 5.00 6


0.03 0.00 2 13.51 0.00 6 1.77 C 0.00 5
MIN -0.66 5.00 6 -1.17 0.00 6
-10.96 5.00 6 -41.28 5.00 6 134.23 T 5.00 6

130 MAX 18.28 0.00 6 22.28 0.00 6


69.76 0.00 6 39.83 2.50 6 0.91 C 0.00 4
MIN -0.40 2.50 1 -23.43 2.50 6
-0.67 2.50 1 -134.56 0.00 6 1.50 T 2.50 6

131 MAX 19.10 0.00 6 24.06 0.00 6


15.04 0.00 6 69.26 2.50 6 0.61 C 0.00 5
MIN -0.41 2.50 1 -23.70 2.50 6
0.01 2.50 2 -1.63 0.00 1 5.07 T 2.50 6

132 MAX 2.12 0.00 6 3.68 0.00 6


1.33 0.00 1 61.84 0.00 6 0.27 C 0.00 2
STAAD SPACE -- PAGE NO. 200

MIN -0.41 2.50 4 -1.63 2.50 6


-71.08 2.50 6 -115.85 2.50 6 9.98 T 2.50 6

133 MAX 0.63 0.00 6 2.02 0.00 6


10.38 0.00 6 12.56 5.00 6 4.53 C 0.00 1
MIN -0.01 5.00 4 -1.14 5.00 6
-0.10 5.00 1 -39.36 0.00 6 135.35 T 5.00 6

134 MAX 0.10 0.00 4 0.30 5.00 5


0.04 0.00 5 4.59 0.00 6 6.22 C 0.00 1
MIN -0.09 5.00 5 -0.24 5.00 4
-0.03 5.00 4 -0.56 5.00 1 134.51 T 5.00 6

135 MAX -0.00 0.00 2 2.02 5.00 6


0.14 0.00 1 12.56 0.00 6 4.61 C 0.00 1
MIN -0.63 5.00 6 -1.14 0.00 6
-10.38 5.00 6 -39.36 5.00 6 135.35 T 5.00 6

136 MAX 0.49 0.00 4 3.68 2.50 6


71.08 0.00 6 61.84 2.50 6 0.31 C 0.00 2
MIN -2.12 2.50 6 -1.63 0.00 6
-1.42 2.50 1 -115.85 0.00 6 9.98 T 2.50 6

137 MAX 18.02 0.00 6 21.34 0.00 6


43.32 0.00 6 69.26 2.50 6 0.10 C 0.00 5
MIN -0.15 2.50 5 -23.70 2.50 6
-0.26 2.50 1 -39.04 0.00 6 5.07 T 2.50 6

138 MAX 18.84 0.00 6 23.67 0.00 6


0.71 0.00 1 68.31 0.00 6 1.04 C 0.00 4
MIN -0.11 2.50 5 -23.43 2.50 6
-11.39 2.50 6 -1.56 0.00 1 1.50 T 2.50 6

139 MAX 1.25 0.00 3 53.62 2.50 1


0.11 0.00 2 1.01 0.00 6 6.97 C 0.00 6
MIN -55.96 2.50 1 -37.78 0.00 1
-0.31 2.50 1 -0.63 2.50 1 14.40 T 2.50 1

140 MAX 51.39 0.00 1 53.21 0.00 1


0.09 0.00 1 11.06 0.00 6 0.26 C 0.00 2
MIN -33.67 5.00 1 -24.32 2.92 1
-3.34 5.00 6 -5.64 5.00 6 4.79 T 5.00 6

141 MAX 1.35 0.00 3 50.43 2.50 1


0.07 0.00 2 6.66 0.00 6 3.63 C 0.00 6
MIN -53.91 2.50 1 -35.84 0.00 1
-4.60 2.50 6 -4.85 2.50 6 13.79 T 2.50 1

142 MAX 47.34 0.00 1 49.26 0.00 1


3.34 0.00 6 5.64 5.00 6 0.16 C 0.00 2
MIN -30.83 5.00 1 -22.33 2.92 1
-0.10 5.00 1 -11.06 0.00 6 4.79 T 5.00 6

143 MAX 2.70 0.00 2 39.02 2.50 1


0.77 0.00 5 1.03 2.50 1 0.53 C 0.00 3
STAAD SPACE -- PAGE NO. 201

MIN -42.83 2.50 1 -24.91 0.00 1


-1.42 2.50 6 -4.62 2.50 6 4.57 T 2.50 1

144 MAX 25.44 0.00 1 27.02 0.00 1


0.03 0.00 5 0.09 5.00 5 2.83 C 0.00 6
MIN -16.54 5.00 1 -11.47 2.92 1
-0.02 5.00 4 -0.08 5.00 4 1.64 T 5.00 5

147 MAX 0.06 0.00 4 36.41 2.50 1


2.81 0.00 6 3.34 2.50 6 0.36 C 0.00 2
MIN -42.61 2.50 1 -21.62 0.00 1
-0.34 2.50 1 -3.68 0.00 6 8.94 T 2.50 1

148 MAX 38.24 0.00 1 32.31 0.00 1


0.66 0.00 1 26.38 0.00 6 7.04 C 0.00 6
MIN -8.45 2.50 1 -6.82 2.08 1
-16.45 2.50 6 -14.74 2.50 6 0.50 T 2.50 1

149 MAX 2.06 0.00 2 36.34 2.50 1


0.36 0.00 1 3.68 0.00 6 0.31 C 0.00 3
MIN -42.58 2.50 1 -21.59 0.00 1
-2.81 2.50 6 -3.34 2.50 6 8.94 T 2.50 1

150 MAX 38.25 0.00 1 32.34 0.00 1


16.45 0.00 6 14.74 2.50 6 7.04 C 0.00 6
MIN -8.43 2.50 1 -6.84 2.08 1
-0.69 2.50 1 -26.38 0.00 6 0.54 T 2.50 1

155 MAX 42.81 0.00 1 88.92 12.50 1


0.02 0.00 3 0.19 12.50 1 3.08 C 0.00 3
MIN -42.90 12.50 1 -45.29 6.25 1
-0.01 12.50 2 -1.15 12.50 6 13.14 T 12.50 5

156 MAX 51.48 0.00 1 106.86 12.50 1


0.00 0.00 2 1.15 12.50 6 3.19 C 0.00 2
MIN -51.57 12.50 1 -54.44 6.25 1
-0.02 12.50 3 -0.21 12.50 1 14.80 T 12.50 1

157 MAX -0.00 0.00 5 37.05 2.50 1


0.09 0.00 2 2.34 0.00 6 4.98 C 0.00 6
MIN -42.52 2.50 1 -20.78 0.00 1
-0.97 2.50 6 -0.10 0.00 5 8.22 T 2.50 1

158 MAX 35.67 0.00 1 31.00 0.00 1


7.74 0.00 6 2.76 2.50 6 1.64 C 0.00 6
MIN -6.86 2.50 1 -6.40 2.08 1
-0.08 2.50 3 -16.59 0.00 6 0.18 T 2.50 2

159 MAX -0.03 0.00 4 35.02 2.50 1


0.18 0.00 1 0.26 2.50 1 0.24 C 0.00 3
MIN -41.38 2.50 1 -19.96 0.00 1
-0.67 2.50 6 -2.10 2.50 6 8.13 T 2.50 1

160 MAX 33.32 0.00 1 29.45 0.00 1


0.09 0.00 3 16.59 0.00 6 1.64 C 0.00 6
STAAD SPACE -- PAGE NO. 202

MIN -5.76 2.50 1 -6.04 2.08 1


-7.74 2.50 6 -2.76 2.50 6 0.16 T 2.50 2

161 MAX 1.07 0.00 6 39.26 2.50 1


1.33 0.00 6 4.51 2.50 6 0.16 C 0.00 3
MIN -46.95 2.50 1 -19.76 0.00 1
-0.35 2.50 4 -0.62 2.50 1 4.42 T 2.50 6

162 MAX 20.51 0.00 1 21.25 0.00 1


0.08 0.00 4 0.14 2.50 4 2.67 C 0.00 6
MIN -5.10 2.50 2 -3.79 2.50 1
-0.08 2.50 5 -0.14 2.50 5 0.56 T 2.50 4

163 MAX 16.06 0.00 1 8.70 2.50 1


0.49 0.00 1 34.53 0.00 6 4.10 C 0.00 1
MIN -18.47 2.50 1 -3.60 1.25 1
-32.02 2.50 6 -45.52 2.50 6 30.53 T 2.50 6

164 MAX 18.43 0.00 1 8.65 0.00 1


32.02 0.00 6 34.53 2.50 6 4.06 C 0.00 1
MIN -16.10 2.50 1 -3.59 1.25 1
-0.47 2.50 1 -45.52 0.00 6 30.53 T 2.50 6

165 MAX -0.00 0.00 6 49.62 2.50 1


10.16 0.00 6 11.48 2.50 6 20.13 C 0.00 1
MIN -54.59 2.50 1 -38.36 0.00 1
-1.58 2.50 1 -13.91 0.00 6 0.21 C 2.50 3

166 MAX 51.62 0.00 1 53.70 0.00 1


0.20 0.00 1 24.74 0.00 6 3.04 C 0.00 1
MIN -33.44 5.00 1 -24.52 2.92 1
-7.40 5.00 6 -12.26 5.00 6 10.73 T 5.00 6

167 MAX 1.15 0.00 5 52.28 2.50 1


0.57 0.00 6 2.02 0.00 1 19.22 C 0.00 1
MIN -55.00 2.50 1 -36.73 0.00 1
-1.34 2.50 1 -1.65 0.00 6 0.28 C 2.50 3

168 MAX 47.57 0.00 1 49.73 0.00 1


7.40 0.00 6 12.26 5.00 6 2.85 C 0.00 1
MIN -30.60 5.00 1 -22.51 2.92 1
-0.22 5.00 1 -24.74 0.00 6 10.73 T 5.00 6

169 MAX 0.16 0.00 2 39.17 2.50 1


3.84 0.00 1 4.10 2.50 1 7.98 C 0.00 1
MIN -43.03 2.50 1 -25.24 0.00 1
-0.02 2.50 6 -5.51 0.00 1 60.94 T 2.50 6

170 MAX 24.91 0.00 1 24.78 0.00 1


0.04 0.00 2 0.13 5.00 2 7.69 C 0.00 1
MIN -17.07 5.00 1 -12.15 2.92 1
-0.04 5.00 3 -0.13 5.00 3 0.03 T 5.00 6

171 MAX 0.64 0.00 6 39.98 2.50 1


2.58 0.00 1 4.62 0.00 6 1.85 C 0.00 1
STAAD SPACE -- PAGE NO. 203

MIN -47.54 2.50 1 -20.51 0.00 1


-0.62 2.50 6 -3.69 0.00 1 51.97 T 2.50 6

172 MAX 19.35 0.00 1 18.64 0.00 1


0.10 0.00 3 0.17 2.50 3 5.12 C 0.00 1
MIN -5.35 2.50 4 -3.66 2.29 1
-0.11 2.50 2 -0.18 2.50 2 1.24 T 2.50 6

173 MAX -0.00 0.00 3 37.53 2.50 1


0.31 0.00 1 3.51 0.00 6 14.37 C 0.00 6
MIN -42.81 2.50 1 -21.02 0.00 1
-0.42 2.50 6 -0.35 0.00 1 0.25 C 2.50 3

174 MAX 36.11 0.00 1 31.62 0.00 1


16.04 0.00 6 4.85 2.50 6 1.81 C 0.00 6
MIN -6.42 2.50 1 -6.69 2.08 1
-0.37 2.50 1 -35.25 0.00 6 0.50 T 2.50 1

175 MAX -0.02 0.00 2 33.08 2.50 1


0.13 0.00 1 0.20 2.50 1 12.50 C 0.00 1
MIN -40.66 2.50 1 -20.09 0.00 1
-1.39 2.50 6 -4.81 2.50 6 1.67 T 2.50 6

176 MAX 33.75 0.00 1 30.05 0.00 1


0.39 0.00 1 35.25 0.00 6 1.81 C 0.00 6
MIN -5.34 2.50 1 -6.33 2.08 1
-16.04 2.50 6 -4.85 2.50 6 0.42 T 2.50 1

177 MAX 1.78 0.00 5 38.69 2.50 1


16.60 0.00 6 2.00 2.50 6 14.42 C 0.00 1
MIN -43.74 2.50 1 -22.15 0.00 1
-0.32 2.50 1 -39.49 0.00 6 41.63 T 2.50 6

178 MAX 38.60 0.00 1 32.78 0.00 1


1.06 0.00 1 61.20 0.00 6 0.38 C 0.00 1
MIN -8.08 2.50 1 -7.12 2.08 1
-40.48 2.50 6 -40.01 2.50 6 14.95 T 2.50 6

179 MAX 1.99 0.00 4 34.51 2.50 1


0.10 0.00 2 0.52 0.00 6 13.40 C 0.00 1
MIN -41.92 2.50 1 -21.80 0.00 1
-1.64 2.50 6 -3.58 2.50 6 1.14 T 2.50 6

180 MAX 38.61 0.00 1 32.77 0.00 1


40.48 0.00 6 40.01 2.50 6 0.39 C 0.00 1
MIN -8.08 2.50 1 -7.13 2.08 1
-1.18 2.50 1 -61.20 0.00 6 14.95 T 2.50 6

181 MAX 20.18 0.00 6 35.41 2.50 1


14.40 0.00 6 41.43 2.50 6 0.81 C 0.00 3
MIN -41.47 2.50 1 -24.98 2.50 6
0.03 2.50 2 -3.56 0.00 1 0.53 T 2.50 2

182 MAX 40.14 0.00 6 66.31 0.00 6


24.20 0.00 6 40.41 2.50 6 62.39 C 0.00 6
STAAD SPACE -- PAGE NO. 204

MIN -4.52 2.50 1 -34.03 2.50 6


-0.23 2.50 3 -20.10 0.00 6 0.13 C 2.50 2

183 MAX 19.96 0.00 6 37.41 2.50 1


47.99 0.00 6 84.99 2.50 6 24.90 C 0.00 6
MIN -44.43 2.50 1 -24.11 2.50 6
0.03 2.50 3 -34.99 0.00 6 0.03 T 2.50 5

184 MAX 40.14 0.00 6 66.31 0.00 6


0.12 0.00 5 20.10 0.00 6 62.39 C 0.00 6
MIN -4.06 2.50 1 -34.03 2.50 6
-24.20 2.50 6 -40.41 2.50 6 0.14 C 2.50 3

185 MAX 51.46 0.00 1 106.95 12.50 1


0.01 0.00 4 1.56 0.00 6 17.82 C 0.00 1
MIN -51.59 12.50 1 -54.46 6.25 1
-0.02 12.50 1 -0.37 12.50 1 2.31 T 12.50 4

186 MAX 42.80 0.00 1 89.01 12.50 1


0.03 0.00 3 0.35 12.50 1 15.40 C 0.00 1
MIN -42.92 12.50 1 -45.30 6.25 1
-0.01 12.50 2 -1.56 0.00 6 1.83 T 12.50 5

187 MAX 38.75 0.00 1 32.49 5.00 1


0.05 0.00 2 0.42 5.00 1 0.34 C 0.00 3
MIN -38.85 5.00 1 -16.14 2.50 1
-3.05 5.00 6 -16.97 5.00 6 18.57 T 5.00 6

188 MAX 38.77 0.00 1 32.44 5.00 1


3.05 0.00 6 16.97 5.00 6 0.33 C 0.00 3
MIN -38.83 5.00 1 -16.14 2.50 1
-0.03 5.00 3 -0.41 5.00 1 18.57 T 5.00 6

189 MAX 19.70 0.00 6 34.57 2.50 1


0.96 0.00 1 1.75 2.50 1 22.35 C 0.00 6
MIN -40.86 2.50 1 -23.34 2.50 6
-5.30 2.50 6 -19.44 2.50 6 0.80 T 2.50 5

190 MAX 40.53 0.00 6 76.43 0.00 6


6.78 0.00 6 8.38 2.50 6 11.37 C 0.00 6
MIN -3.55 2.50 1 -24.91 2.50 6
-0.28 2.50 1 -8.56 0.00 6 1.85 T 2.50 1

191 MAX 19.70 0.00 6 37.10 2.50 1


5.30 0.00 6 19.44 2.50 6 22.35 C 0.00 6
MIN -44.05 2.50 1 -23.34 2.50 6
-1.01 2.50 1 -1.84 2.50 1 0.81 T 2.50 1

192 MAX 40.53 0.00 6 76.43 0.00 6


0.29 0.00 1 8.56 0.00 6 11.37 C 0.00 6
MIN -3.27 2.50 2 -24.91 2.50 6
-6.78 2.50 6 -8.38 2.50 6 1.94 T 2.50 1

193 MAX 0.05 0.00 6 0.71 12.50 1


0.00 0.00 4 1.93 0.00 6 15.27 C 0.00 1
STAAD SPACE -- PAGE NO. 205

MIN -0.05 12.50 1 -0.33 12.50 6


-0.02 12.50 1 -0.29 12.50 1 2.71 T 12.50 2

194 MAX 0.05 0.00 1 0.64 0.00 1


0.03 0.00 3 1.93 12.50 6 12.90 C 0.00 5
MIN -0.05 12.50 6 -0.33 0.00 6
-0.01 12.50 2 -0.28 0.00 1 2.43 T 12.50 3

195 MAX 0.45 0.00 1 24.06 2.50 6


-0.01 0.00 5 69.26 0.00 6 0.10 C 0.00 5
MIN -19.10 2.50 6 -23.70 0.00 6
-15.04 2.50 6 -1.72 2.50 1 5.07 T 2.50 6

196 MAX 0.15 0.00 5 21.34 2.50 6


0.24 0.00 1 69.26 0.00 6 0.61 C 0.00 5
MIN -18.02 2.50 6 -23.70 0.00 6
-43.32 2.50 6 -39.04 2.50 6 5.07 T 2.50 6

197 MAX 0.42 0.00 1 22.28 2.50 6


0.71 0.00 1 39.83 0.00 6 1.04 C 0.00 4
MIN -18.28 2.50 6 -23.43 0.00 6
-69.76 2.50 6 -134.56 2.50 6 1.50 T 2.50 6

198 MAX 0.12 0.00 5 23.67 2.50 6


11.39 0.00 6 68.31 2.50 6 0.91 C 0.00 4
MIN -18.84 2.50 6 -23.43 0.00 6
-0.67 2.50 1 -1.47 2.50 1 1.50 T 2.50 6

********** END OF FORCE ENVELOPE FROM INTERNAL STORAGE **********

210. PRINT SUPPORT REACTION LIST 29 TO 56


STAAD SPACE -- PAGE NO. 206

SUPPORT REACTIONS -UNIT KN METE STRUCTURE TYPE = SPACE


-----------------

JOINT LOAD FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM Z

29 1 6.34 186.49 -4.65 0.00 0.00 0.00


2 1.78 10.43 -0.47 0.00 0.00 0.00
3 0.30 7.51 -0.82 0.00 0.00 0.00
4 -0.57 9.80 -0.01 0.00 0.00 0.00
5 -0.06 7.43 0.37 0.00 0.00 0.00
6 -0.13 1.79 -1.30 0.00 0.00 0.00
30 1 -1.74 190.56 -1.32 0.00 0.00 0.00
2 -1.56 6.69 -0.35 0.00 0.00 0.00
3 0.37 10.68 0.09 0.00 0.00 0.00
4 0.71 6.43 -0.14 0.00 0.00 0.00
5 -0.07 10.70 -0.11 0.00 0.00 0.00
6 -0.05 -0.12 0.18 0.00 0.00 0.00
31 1 -0.01 204.42 -6.37 0.00 0.00 0.00
2 0.80 6.15 -0.21 0.00 0.00 0.00
3 -0.80 24.18 -2.87 0.00 0.00 0.00
4 -0.28 5.90 -0.20 0.00 0.00 0.00
5 0.01 29.78 -1.05 0.00 0.00 0.00
6 -0.00 0.01 -1.63 0.00 0.00 0.00
32 1 1.54 187.67 -1.21 0.00 0.00 0.00
2 0.68 15.61 -0.30 0.00 0.00 0.00
3 0.35 1.05 0.08 0.00 0.00 0.00
4 -0.28 15.74 -0.12 0.00 0.00 0.00
5 0.07 10.71 -0.11 0.00 0.00 0.00
6 0.05 -0.12 0.18 0.00 0.00 0.00
33 1 -6.15 183.69 -4.58 0.00 0.00 0.00
2 -1.40 6.22 -0.42 0.00 0.00 0.00
3 -0.53 11.00 -0.82 0.00 0.00 0.00
4 0.53 5.97 -0.01 0.00 0.00 0.00
5 0.06 7.40 0.38 0.00 0.00 0.00
6 0.13 1.79 -1.30 0.00 0.00 0.00
34 1 1.03 188.84 -0.56 0.00 0.00 0.00
2 -0.01 6.45 -1.16 0.00 0.00 0.00
3 0.47 13.27 1.19 0.00 0.00 0.00
4 -0.04 6.73 0.26 0.00 0.00 0.00
5 -0.01 10.35 -0.41 0.00 0.00 0.00
6 -1.83 4.13 -1.75 0.00 0.00 0.00
35 1 -1.06 188.97 -0.53 0.00 0.00 0.00
2 -0.49 13.43 -1.15 0.00 0.00 0.00
3 0.02 6.34 1.18 0.00 0.00 0.00
4 0.00 10.69 0.26 0.00 0.00 0.00
5 -0.00 6.54 -0.40 0.00 0.00 0.00
6 1.83 4.13 -1.75 0.00 0.00 0.00
36 1 4.28 199.58 -0.24 0.00 0.00 0.00
2 0.89 15.18 0.67 0.00 0.00 0.00
3 0.29 7.75 -0.70 0.00 0.00 0.00
4 0.31 14.88 -0.43 0.00 0.00 0.00
STAAD SPACE -- PAGE NO. 207

SUPPORT REACTIONS -UNIT KN METE STRUCTURE TYPE = SPACE


-----------------

JOINT LOAD FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM Z

5 0.12 7.54 0.39 0.00 0.00 0.00


6 23.07 80.26 -1.53 0.00 0.00 0.00
37 1 -4.10 198.63 -0.21 0.00 0.00 0.00
2 -0.22 7.60 0.70 0.00 0.00 0.00
3 -0.90 15.08 -0.72 0.00 0.00 0.00
4 -0.10 7.56 -0.44 0.00 0.00 0.00
5 -0.32 14.75 0.42 0.00 0.00 0.00
6 -23.07 80.26 -1.53 0.00 0.00 0.00
38 1 -0.64 164.83 -0.43 0.00 0.00 0.00
2 -0.08 0.95 -0.49 0.00 0.00 0.00
3 -0.02 14.14 0.10 0.00 0.00 0.00
4 -0.00 0.95 0.10 0.00 0.00 0.00
5 0.00 14.24 0.09 0.00 0.00 0.00
6 3.77 2.12 -1.55 0.00 0.00 0.00
39 1 0.64 164.82 -0.41 0.00 0.00 0.00
2 0.03 3.46 -1.02 0.00 0.00 0.00
3 0.07 11.63 0.63 0.00 0.00 0.00
4 0.02 3.44 0.33 0.00 0.00 0.00
5 -0.02 11.74 -0.12 0.00 0.00 0.00
6 -3.77 2.12 -1.55 0.00 0.00 0.00
40 1 4.15 167.59 4.09 0.00 0.00 0.00
2 0.35 8.53 0.31 0.00 0.00 0.00
3 0.79 7.12 0.91 0.00 0.00 0.00
4 -0.09 8.65 -0.19 0.00 0.00 0.00
5 -0.25 6.73 -0.22 0.00 0.00 0.00
6 0.02 1.47 -1.05 0.00 0.00 0.00
41 1 -4.09 166.61 4.11 0.00 0.00 0.00
2 -0.21 7.78 0.89 0.00 0.00 0.00
3 -0.88 7.63 0.34 0.00 0.00 0.00
4 0.06 7.77 -0.39 0.00 0.00 0.00
5 0.27 7.49 -0.01 0.00 0.00 0.00
6 -0.02 1.47 -1.05 0.00 0.00 0.00
42 1 -0.13 163.03 -0.48 0.00 0.00 0.00
2 -0.30 0.62 -0.11 0.00 0.00 0.00
3 -0.07 12.97 0.03 0.00 0.00 0.00
4 0.18 0.65 0.07 0.00 0.00 0.00
5 0.02 12.91 0.00 0.00 0.00 0.00
6 -0.02 0.85 0.71 0.00 0.00 0.00
43 1 -0.01 194.73 5.06 0.00 0.00 0.00
2 0.78 16.45 1.14 0.00 0.00 0.00
3 -0.78 7.42 0.55 0.00 0.00 0.00
4 -0.30 16.23 0.45 0.00 0.00 0.00
5 0.30 7.23 0.40 0.00 0.00 0.00
6 0.00 3.46 2.78 0.00 0.00 0.00
44 1 0.04 161.91 -0.48 0.00 0.00 0.00
2 -0.50 10.20 -0.11 0.00 0.00 0.00
STAAD SPACE -- PAGE NO. 208

SUPPORT REACTIONS -UNIT KN METE STRUCTURE TYPE = SPACE


-----------------

JOINT LOAD FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM Z

3 0.79 3.11 0.03 0.00 0.00 0.00


4 0.18 10.31 0.07 0.00 0.00 0.00
5 -0.36 3.09 0.01 0.00 0.00 0.00
6 0.02 0.85 0.71 0.00 0.00 0.00
45 1 3.02 252.52 5.83 0.00 0.00 0.00
2 1.73 30.42 2.08 0.00 0.00 0.00
3 -0.48 11.92 -0.08 0.00 0.00 0.00
4 -0.23 24.08 -0.28 0.00 0.00 0.00
5 0.18 8.86 0.01 0.00 0.00 0.00
6 -1.84 30.66 1.51 0.00 0.00 0.00
46 1 1.40 258.57 -14.89 0.00 0.00 0.00
2 -1.24 54.26 -14.38 0.00 0.00 0.00
3 2.57 17.14 0.51 0.00 0.00 0.00
4 0.06 44.41 2.60 0.00 0.00 0.00
5 -0.35 12.90 -0.04 0.00 0.00 0.00
6 -0.25 -1.35 0.54 0.00 0.00 0.00
47 1 -1.44 241.35 -12.34 0.00 0.00 0.00
2 -1.20 10.54 -0.23 0.00 0.00 0.00
3 -0.15 57.94 -12.56 0.00 0.00 0.00
4 0.06 6.20 0.04 0.00 0.00 0.00
5 0.20 51.15 2.53 0.00 0.00 0.00
6 0.25 -1.35 0.54 0.00 0.00 0.00
48 1 -3.07 240.54 5.42 0.00 0.00 0.00
2 0.44 21.40 1.86 0.00 0.00 0.00
3 -1.71 17.95 -0.11 0.00 0.00 0.00
4 -0.19 18.84 -0.28 0.00 0.00 0.00
5 0.19 12.28 0.04 0.00 0.00 0.00
6 1.84 30.66 1.51 0.00 0.00 0.00
49 1 0.48 129.91 -3.57 0.00 0.00 0.00
2 -0.04 3.15 -1.34 0.00 0.00 0.00
3 0.01 17.75 -0.34 0.00 0.00 0.00
4 0.08 3.18 0.35 0.00 0.00 0.00
5 0.08 16.75 0.11 0.00 0.00 0.00
6 -0.87 17.83 4.40 0.00 0.00 0.00
50 1 -0.45 120.36 -3.33 0.00 0.00 0.00
2 -0.01 0.63 -0.81 0.00 0.00 0.00
3 0.04 17.88 -0.70 0.00 0.00 0.00
4 -0.05 0.69 0.25 0.00 0.00 0.00
5 -0.10 17.89 0.18 0.00 0.00 0.00
6 0.87 17.83 4.40 0.00 0.00 0.00
51 1 0.64 174.46 0.32 0.00 0.00 0.00
2 -0.05 25.72 -0.59 0.00 0.00 0.00
3 0.03 2.10 0.73 0.00 0.00 0.00
4 0.15 24.40 0.23 0.00 0.00 0.00
5 0.07 2.10 -0.15 0.00 0.00 0.00
6 -19.39 33.84 -2.40 0.00 0.00 0.00
STAAD SPACE -- PAGE NO. 209

SUPPORT REACTIONS -UNIT KN METE STRUCTURE TYPE = SPACE


-----------------

JOINT LOAD FORCE-X FORCE-Y FORCE-Z MOM-X MOM-Y MOM Z

52 1 -0.60 161.13 0.36 0.00 0.00 0.00


2 -0.01 20.41 -0.91 0.00 0.00 0.00
3 0.04 4.07 1.09 0.00 0.00 0.00
4 -0.07 20.33 0.28 0.00 0.00 0.00
5 -0.14 4.27 -0.21 0.00 0.00 0.00
6 19.39 33.84 -2.40 0.00 0.00 0.00
53 1 1.00 325.45 0.81 0.00 0.00 0.00
2 1.50 28.04 1.33 0.00 0.00 0.00
3 -0.97 18.52 -0.79 0.00 0.00 0.00
4 -0.30 27.16 -0.13 0.00 0.00 0.00
5 0.26 18.17 0.17 0.00 0.00 0.00
6 -1.43 52.10 1.18 0.00 0.00 0.00
54 1 -1.01 313.98 0.61 0.00 0.00 0.00
2 0.99 21.51 1.07 0.00 0.00 0.00
3 -1.52 22.17 -0.63 0.00 0.00 0.00
4 -0.29 21.39 -0.12 0.00 0.00 0.00
5 0.32 22.33 0.15 0.00 0.00 0.00
6 1.43 52.10 1.18 0.00 0.00 0.00
55 1 0.01 290.84 15.76 0.00 0.00 0.00
2 -0.81 57.14 14.08 0.00 0.00 0.00
3 1.23 10.07 0.30 0.00 0.00 0.00
4 0.13 54.08 -2.56 0.00 0.00 0.00
5 -0.25 10.31 0.07 0.00 0.00 0.00
6 -0.32 -2.60 0.49 0.00 0.00 0.00
56 1 -0.04 273.64 13.22 0.00 0.00 0.00
2 -1.86 13.29 -0.07 0.00 0.00 0.00
3 1.44 51.00 13.37 0.00 0.00 0.00
4 0.32 13.58 0.02 0.00 0.00 0.00
5 -0.21 50.81 -2.51 0.00 0.00 0.00
6 0.32 -2.60 0.49 0.00 0.00 0.00

************** END OF LATEST ANALYSIS RESULT **************

211. FINISH
STAAD SPACE -- PAGE NO. 210

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= OCT 22,2019 TIME= 23: 4:23 ****

************************************************************
* For technical assistance on STAAD.Pro, please visit *
* http://selectservices.bentley.com/en-US/ *
* *
* Details about additional assistance from *
* Bentley and Partners can be found at program menu *
* Help->Technical Support *
* *
* Copyright (c) 1997-2015 Bentley Systems, Inc.
* http://www.bentley.com *
************************************************************
Isolated Footing Design Page 1 of 352

Isolated Footing Design(ACI 318-05)


Design For Isolated Footing 29

Design For Isolated Footing 30

Design For Isolated Footing 31

Design For Isolated Footing 32

Design For Isolated Footing 33

Design For Isolated Footing 34

Design For Isolated Footing 35

Design For Isolated Footing 36

Design For Isolated Footing 37

Design For Isolated Footing 38

Design For Isolated Footing 39

Design For Isolated Footing 40

Design For Isolated Footing 41

Design For Isolated Footing 42

Design For Isolated Footing 43

Design For Isolated Footing 44

Design For Isolated Footing 45

Design For Isolated Footing 46

Design For Isolated Footing 47

Design For Isolated Footing 48

Design For Isolated Footing 49

Design For Isolated Footing 50

Design For Isolated Footing 51

Design For Isolated Footing 52

Design For Isolated Footing 53

Design For Isolated Footing 54

Design For Isolated Footing 55

Design For Isolated Footing 56

Footing No. Group ID Foundation Geometry


- - Length Width Thickness
29 1 10.667 ft 10.667 ft 1.000 ft
30 2 12.833 ft 12.833 ft 1.000 ft
31 3 15.500 ft 15.500 ft 1.000 ft
32 4 12.833 ft 12.833 ft 1.000 ft
33 5 10.667 ft 10.667 ft 1.000 ft
34 6 15.833 ft 15.833 ft 1.000 ft
35 7 15.833 ft 15.833 ft 1.000 ft
36 8 18.333 ft 18.333 ft 1.000 ft
37 9 18.333 ft 18.333 ft 1.000 ft
38 10 13.500 ft 13.500 ft 1.000 ft
39 11 13.500 ft 13.500 ft 1.000 ft
40 12 11.500 ft 11.500 ft 1.000 ft
41 13 11.500 ft 11.500 ft 1.000 ft
42 14 13.333 ft 13.333 ft 1.000 ft
43 15 17.667 ft 17.667 ft 1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 2 of 352

44 16 13.333 ft 13.333 ft 1.000 ft


45 17 13.167 ft 13.167 ft 1.000 ft
46 18 8.500 ft 8.500 ft 1.000 ft
47 19 8.500 ft 8.500 ft 1.000 ft
48 20 13.167 ft 13.167 ft 1.000 ft
49 21 12.667 ft 12.667 ft 1.000 ft
50 22 12.667 ft 12.667 ft 1.000 ft
51 23 8.167 ft 8.167 ft 1.000 ft
52 24 8.167 ft 8.167 ft 1.000 ft
53 25 8.167 ft 8.167 ft 1.000 ft
54 26 8.167 ft 8.167 ft 1.000 ft
55 27 8.833 ft 8.833 ft 1.000 ft
56 28 8.833 ft 8.833 ft 1.000 ft

Footing No. Footing Reinforcement Pedestal Reinforcement


- Bottom Reinforcement(Mz) Bottom Reinforcement(Mx) Top Reinforcement(Mz) Top Reinforcement(Mx) Main Steel Trans Steel
29 #4 @ 15 in c/c #3 @ 7 in c/c #5 @ 18 in c/c #6 @ 18 in c/c N/A N/A
30 #4 @ 14 in c/c #3 @ 7 in c/c #3 @ 7 in c/c #5 @ 18 in c/c N/A N/A
31 #4 @ 11 in c/c #3 @ 6 in c/c #3 @ 7 in c/c #4 @ 14 in c/c N/A N/A
32 #4 @ 14 in c/c #3 @ 7 in c/c #3 @ 7 in c/c #5 @ 18 in c/c N/A N/A
33 #3 @ 8 in c/c #3 @ 7 in c/c #5 @ 18 in c/c #6 @ 18 in c/c N/A N/A
34 #3 @ 5 in c/c #3 @ 5 in c/c #3 @ 7 in c/c #6 @ 18 in c/c N/A N/A
35 #3 @ 5 in c/c #3 @ 5 in c/c #3 @ 7 in c/c #6 @ 18 in c/c N/A N/A
36 #4 @ 8 in c/c #3 @ 4 in c/c #3 @ 7 in c/c #6 @ 18 in c/c N/A N/A
37 #4 @ 8 in c/c #3 @ 4 in c/c #3 @ 7 in c/c #6 @ 18 in c/c N/A N/A
38 #4 @ 15 in c/c #4 @ 14 in c/c #8 @ 18 in c/c #3 @ 8 in c/c N/A N/A
39 #4 @ 15 in c/c #4 @ 14 in c/c #8 @ 18 in c/c #3 @ 8 in c/c N/A N/A
40 #3 @ 7 in c/c #4 @ 14 in c/c #9 @ 18 in c/c #6 @ 18 in c/c N/A N/A
41 #3 @ 7 in c/c #4 @ 14 in c/c #9 @ 18 in c/c #6 @ 18 in c/c N/A N/A
42 #4 @ 15 in c/c #3 @ 7 in c/c #3 @ 7 in c/c #6 @ 18 in c/c N/A N/A
43 #3 @ 5 in c/c #3 @ 5 in c/c #6 @ 18 in c/c #5 @ 18 in c/c N/A N/A
44 #4 @ 15 in c/c #3 @ 7 in c/c #3 @ 7 in c/c #6 @ 18 in c/c N/A N/A
45 #3 @ 4 in c/c #4 @ 8 in c/c #3 @ 7 in c/c #5 @ 18 in c/c N/A N/A
46 #5 @ 15 in c/c #5 @ 18 in c/c #3 @ 7 in c/c #4 @ 15 in c/c N/A N/A
47 #3 @ 5 in c/c #3 @ 6 in c/c #3 @ 7 in c/c #4 @ 15 in c/c N/A N/A
48 #5 @ 12 in c/c #5 @ 13 in c/c #3 @ 7 in c/c #5 @ 18 in c/c N/A N/A
49 #3 @ 7 in c/c #4 @ 14 in c/c #6 @ 18 in c/c #9 @ 18 in c/c N/A N/A
50 #4 @ 14 in c/c #4 @ 14 in c/c #6 @ 18 in c/c #9 @ 18 in c/c N/A N/A
51 #4 @ 15 in c/c #3 @ 7 in c/c #3 @ 7 in c/c #4 @ 15 in c/c N/A N/A
52 #4 @ 15 in c/c #3 @ 7 in c/c #3 @ 7 in c/c #4 @ 15 in c/c N/A N/A
53 #3 @ 4 in c/c #6 @ 18 in c/c #3 @ 7 in c/c #4 @ 15 in c/c N/A N/A
54 #3 @ 4 in c/c #5 @ 15 in c/c #3 @ 7 in c/c #4 @ 15 in c/c N/A N/A
55 #5 @ 14 in c/c #5 @ 16 in c/c #3 @ 7 in c/c #3 @ 7 in c/c N/A N/A
56 #3 @ 4 in c/c #3 @ 5 in c/c #3 @ 7 in c/c #3 @ 7 in c/c N/A N/A

Isolated Footing 29

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 3 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 4 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 5 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 41.926 -1.425 1.046 0.000 0.000
2 2.344 -0.401 0.106 0.000 0.000
3 1.688 -0.068 0.184 0.000 0.000
4 2.203 0.129 0.001 0.000 0.000
5 1.671 0.013 -0.084 0.000 0.000
6 0.402 0.030 0.293 0.000 0.000
7 -2.978 3.815 -0.198 0.000 0.000
8 2.779 -1.676 -0.033 0.000 0.000
9 4.094 -0.102 2.114 0.000 0.000
10 -4.197 0.117 -4.192 0.000 0.000
11 58.696 -1.994 1.465 0.000 0.000
12 56.936 -2.316 1.437 0.000 0.000
13 56.737 -1.597 1.699 0.000 0.000
14 54.969 -2.050 1.746 0.000 0.000
15 54.845 -1.601 1.910 0.000 0.000
16 48.572 1.391 1.566 0.000 0.000
17 53.177 -3.002 1.698 0.000 0.000
18 54.229 -1.743 3.415 0.000 0.000
19 47.596 -1.567 -1.629 0.000 0.000
20 49.763 4.021 1.107 0.000 0.000
21 49.638 4.470 1.270 0.000 0.000
22 58.973 -4.764 1.371 0.000 0.000
23 58.848 -4.315 1.535 0.000 0.000
24 61.077 -2.246 4.806 0.000 0.000
25 60.953 -1.797 4.970 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 6 of 352

26 47.812 -1.895 -5.283 0.000 0.000


27 47.688 -1.446 -5.120 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 41.926 -1.425 1.046 0.000 0.000
2 2.344 -0.401 0.106 0.000 0.000
3 1.688 -0.068 0.184 0.000 0.000
4 2.203 0.129 0.001 0.000 0.000
5 1.671 0.013 -0.084 0.000 0.000
6 0.402 0.030 0.293 0.000 0.000
7 -2.978 3.815 -0.198 0.000 0.000
8 2.779 -1.676 -0.033 0.000 0.000
9 4.094 -0.102 2.114 0.000 0.000
10 -4.197 0.117 -4.192 0.000 0.000
11 58.696 -1.994 1.465 0.000 0.000
12 56.936 -2.316 1.437 0.000 0.000
13 56.737 -1.597 1.699 0.000 0.000
14 54.969 -2.050 1.746 0.000 0.000
15 54.845 -1.601 1.910 0.000 0.000
16 48.572 1.391 1.566 0.000 0.000
17 53.177 -3.002 1.698 0.000 0.000
18 54.229 -1.743 3.415 0.000 0.000
19 47.596 -1.567 -1.629 0.000 0.000
20 49.763 4.021 1.107 0.000 0.000
21 49.638 4.470 1.270 0.000 0.000
22 58.973 -4.764 1.371 0.000 0.000
23 58.848 -4.315 1.535 0.000 0.000
24 61.077 -2.246 4.806 0.000 0.000
25 60.953 -1.797 4.970 0.000 0.000
26 47.812 -1.895 -5.283 0.000 0.000
27 47.688 -1.446 -5.120 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 15.687 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 10.667 ft Governing Load Case : # 10

Width (W2) = 10.667 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 113.778 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 7 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

22 0.6851 0.6380 0.6515 0.6986 0.000

25 0.6700 0.6523 0.7014 0.7192 0.000

25 0.6700 0.6523 0.7014 0.7192 0.000

24 0.6742 0.6519 0.6995 0.7217 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

22 0.6851 0.6380 0.6515 0.6986

25 0.6700 0.6523 0.7014 0.7192

25 0.6700 0.6523 0.7014 0.7192

24 0.6742 0.6519 0.6995 0.7217

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 20.706 28.195 300.747 220.864

2 24.200 91.617 977.252 258.132

3 137.955 50.922 543.164 1471.524

4 74.857 6453.560 68837.972 798.476

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 8 of 352

5 734.847 111.744 1191.931 7838.370

6 290.414 29.813 318.005 3097.747

7 1.847 35.550 379.197 19.697

8 5.920 300.692 3207.387 63.149

9 103.364 5.005 53.389 1102.544

10 54.859 1.535 16.374 585.163

11 18.995 25.864 275.888 202.608

12 15.979 25.745 274.616 170.439

13 23.104 21.721 231.693 246.444

14 17.573 20.626 220.012 187.446

15 22.464 18.827 200.824 239.621

16 23.600 20.963 223.602 251.735

17 11.699 20.687 220.666 124.788

18 20.450 10.438 111.338 218.131

19 20.627 19.842 211.648 220.018

20 8.310 30.188 322.002 88.636

21 7.461 26.253 280.027 79.585

22 7.980 27.728 295.767 85.120

23 8.796 24.733 263.816 93.824

24 17.393 8.130 86.716 185.522

25 21.703 7.850 83.729 231.501

26 17.118 6.140 65.494 182.596

27 22.391 6.324 67.457 238.842

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 3.815 kip
Governing Restoring Force : 7.045 kip
Minimum Sliding Ratio for the Critical Load Case : 1.847
Critical Load Case for Overturning about X-Direction : 10
Governing Overturning Moment : -4.192 kip-ft
Governing Resisting Moment : 68.639 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 16.374

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -4.192 kip
Governing Restoring Force : 6.435 kip
Minimum Sliding Ratio for the Critical Load Case : 1.535
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -3.815 kip-ft
Governing Resisting Moment : 75.141 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 19.697

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 9 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 58.220 kip, Load Case # 24

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 129.527 kip

Distance along X to design for shear,


Dx = 6.820 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 97.145 kip

Critical load case for Vux is # 24 22.648 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 10 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 129.527 kip

Distance along X to design for shear, Dz = 3.846 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 97.145 kip

Critical load case for Vuz is # 24 22.316 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 24

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 11 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 4.513 ft
a distance, Dx =

Ultimate moment, 59.180 kip-ft

Nominal moment capacity, Mn = 65.756 kip-ft

Required = 0.00163

Since OK

Area of Steel Required, As = 1.843 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 7.602 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


4.263 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 17

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.870 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00166

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 7.602 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 12 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 24

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 4.513 ft
a distance, Dz =

Ultimate moment, 60.169 kip-ft

Nominal moment capacity, Mn = 66.854 kip-ft

Required = 0.00183

Since OK

Area of Steel Required, As = 1.782 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.188 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 13 of 352

Available development length for bars, DL


4.263 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 9

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.800 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00176

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 15.188 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 4.513 ft
at a distance, Dx =

Ultimate moment, 16.295 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 14 of 352

Nominal moment capacity, Mn = 18.105 kip-ft

Required = 0.00052

Since OK

Area of Steel Required, As = 1.699 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 4.513 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 15 of 352

Ultimate moment, 16.295 kip-ft

Nominal moment capacity, Mn = 18.105 kip-ft

Required = 0.00044

Since OK

Area of Steel Required, As = 1.843 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 18 in o.c.

Isolated Footing 30

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 16 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 17 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 18 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 42.839 0.391 0.297 0.000 0.000
2 1.505 0.352 0.079 0.000 0.000
3 2.402 -0.083 -0.021 0.000 0.000
4 1.446 -0.160 0.030 0.000 0.000
5 2.405 0.015 0.025 0.000 0.000
6 -0.027 0.012 -0.040 0.000 0.000
7 0.444 2.269 -0.000 0.000 0.000
8 -0.434 -2.179 0.047 0.000 0.000
9 1.042 0.081 0.849 0.000 0.000
10 -1.165 -0.096 -7.809 0.000 0.000
11 59.975 0.548 0.416 0.000 0.000
12 57.650 1.062 0.504 0.000 0.000
13 57.550 0.086 0.352 0.000 0.000
14 55.275 0.855 0.398 0.000 0.000
15 55.212 0.245 0.303 0.000 0.000
16 51.720 2.303 0.293 0.000 0.000
17 51.018 -1.255 0.331 0.000 0.000
18 52.198 0.553 0.973 0.000 0.000
19 50.433 0.412 -5.954 0.000 0.000
20 56.014 4.472 0.441 0.000 0.000
21 55.952 3.862 0.346 0.000 0.000
22 54.610 -2.645 0.517 0.000 0.000
23 54.548 -3.255 0.422 0.000 0.000
24 56.971 0.971 1.800 0.000 0.000
25 56.909 0.361 1.704 0.000 0.000
26 53.440 0.689 -12.053 0.000 0.000
27 53.378 0.079 -12.148 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 42.839 0.391 0.297 0.000 0.000
2 1.505 0.352 0.079 0.000 0.000
3 2.402 -0.083 -0.021 0.000 0.000
4 1.446 -0.160 0.030 0.000 0.000
5 2.405 0.015 0.025 0.000 0.000
6 -0.027 0.012 -0.040 0.000 0.000
7 0.444 2.269 -0.000 0.000 0.000
8 -0.434 -2.179 0.047 0.000 0.000
9 1.042 0.081 0.849 0.000 0.000
10 -1.165 -0.096 -7.809 0.000 0.000
11 59.975 0.548 0.416 0.000 0.000
12 57.650 1.062 0.504 0.000 0.000
13 57.550 0.086 0.352 0.000 0.000
14 55.275 0.855 0.398 0.000 0.000
15 55.212 0.245 0.303 0.000 0.000
16 51.720 2.303 0.293 0.000 0.000
17 51.018 -1.255 0.331 0.000 0.000
18 52.198 0.553 0.973 0.000 0.000
19 50.433 0.412 -5.954 0.000 0.000
20 56.014 4.472 0.441 0.000 0.000
21 55.952 3.862 0.346 0.000 0.000
22 54.610 -2.645 0.517 0.000 0.000
23 54.548 -3.255 0.422 0.000 0.000
24 56.971 0.971 1.800 0.000 0.000
25 56.909 0.361 1.704 0.000 0.000
26 53.440 0.689 -12.053 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 19 of 352

27 53.378 0.079 -12.148 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 15.411 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 12.833 ft Governing Load Case : # 10

Width (W2) = 12.833 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 164.694 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

11 0.5114 0.5145 0.5169 0.5138 0.000

11 0.5114 0.5145 0.5169 0.5138 0.000

11 0.5114 0.5145 0.5169 0.5138 0.000

11 0.5114 0.5145 0.5169 0.5138 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

11 0.5114 0.5145 0.5169 0.5138

11 0.5114 0.5145 0.5169 0.5138

11 0.5114 0.5145 0.5169 0.5138

11 0.5114 0.5145 0.5169 0.5138

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 20 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 86.344 113.522 1456.866 1108.085

2 37.270 165.683 2126.266 478.293

3 162.794 638.930 8199.603 2089.186

4 81.582 430.236 5521.366 1046.968

5 904.375 535.196 6868.354 11606.148

6 1047.155 312.317 4008.062 13438.486

7 5.542 34356.178 440904.282 71.122

8 5.569 258.169 3313.165 71.471

9 159.705 15.168 194.656 2049.547

10 123.010 1.507 19.342 1578.635

11 77.321 101.659 1304.623 992.290

12 38.780 81.651 1047.853 497.680

13 480.396 116.865 1499.768 6165.079

14 46.782 100.426 1288.804 600.366

15 163.304 131.895 1692.650 2095.739

16 16.590 130.201 1670.912 212.906

17 30.168 114.252 1466.234 387.153

18 69.571 39.529 507.287 892.824

19 91.260 6.310 80.981 1171.167

20 9.025 91.503 1174.287 115.818

21 10.443 116.613 1496.531 134.012

22 14.996 76.727 984.659 192.443

23 12.175 93.985 1206.137 156.245

24 42.065 22.693 291.226 539.839

25 113.134 23.943 307.266 1451.882

26 56.728 3.242 41.601 728.012

27 496.468 3.214 41.242 6371.334

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 2.269 kip
Governing Restoring Force : 12.574 kip
Minimum Sliding Ratio for the Critical Load Case : 5.542

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 21 of 352

Critical Load Case for Overturning about X-Direction : 10


Governing Overturning Moment : -7.809 kip-ft
Governing Resisting Moment : 151.043 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 19.342

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -7.809 kip
Governing Restoring Force : 11.770 kip
Minimum Sliding Ratio for the Critical Load Case : 1.507
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -2.269 kip-ft
Governing Resisting Moment : 161.366 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 71.122

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 58.037 kip, Load Case # 11

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 22 of 352

From ACI Cl.11.3.1.1, Vc = 155.837 kip

Distance along X to design for shear,


Dx = 7.904 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 116.878 kip

Critical load case for Vux is # 11 23.085 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 155.837 kip

Distance along X to design for shear, Dz = 7.904 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 116.878 kip

Critical load case for Vuz is # 11 23.099 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 23 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 11

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.596 ft
a distance, Dx =

Ultimate moment, 73.408 kip-ft

Nominal moment capacity, Mn = 81.564 kip-ft

Required = 0.00168

Since OK

Area of Steel Required, As = 2.218 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 7.381 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 24 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.346 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 21

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.310 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00170

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 7.381 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 11

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.596 ft
a distance, Dz =

Ultimate moment, 73.354 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 25 of 352

Nominal moment capacity, Mn = 81.505 kip-ft

Required = 0.00185

Since OK

Area of Steel Required, As = 2.173 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 14.750 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.346 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00179

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 14.750 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 26 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.596 ft
at a distance, Dx =

Ultimate moment, 30.146 kip-ft

Nominal moment capacity, Mn = 33.495 kip-ft

Required = 0.00075

Since OK

Area of Steel Required, As = 2.114 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 27 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.596 ft
at a distance, Dx =

Ultimate moment, 30.146 kip-ft

Nominal moment capacity, Mn = 33.495 kip-ft

Required = 0.00068

Since OK

Area of Steel Required, As = 2.218 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.381 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 31

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 28 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 29 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 30 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 45.955 0.003 1.432 0.000 0.000
2 1.383 -0.181 0.047 0.000 0.000
3 5.437 0.181 0.646 0.000 0.000
4 1.327 0.062 0.044 0.000 0.000
5 6.695 -0.002 0.236 0.000 0.000
6 0.003 0.000 0.367 0.000 0.000
7 0.063 2.269 -0.029 0.000 0.000
8 0.063 -2.269 -0.029 0.000 0.000
9 4.213 0.000 2.958 0.000 0.000
10 -4.790 0.000 -10.330 0.000 0.000
11 64.337 0.004 2.005 0.000 0.000
12 68.073 -0.288 2.356 0.000 0.000
13 65.969 0.392 3.006 0.000 0.000
14 63.229 -0.179 2.590 0.000 0.000
15 61.914 0.246 2.996 0.000 0.000
16 55.201 1.819 2.283 0.000 0.000
17 55.201 -1.812 2.283 0.000 0.000
18 58.521 0.003 4.672 0.000 0.000
19 51.319 0.003 -5.958 0.000 0.000
20 63.326 3.452 2.139 0.000 0.000
21 62.012 3.877 2.545 0.000 0.000
22 63.326 -3.810 2.139 0.000 0.000
23 62.012 -3.385 2.545 0.000 0.000
24 69.967 -0.179 6.918 0.000 0.000
25 68.652 0.246 7.324 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 31 of 352

26 55.562 -0.179 -14.342 0.000 0.000


27 54.248 0.246 -13.935 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 45.955 0.003 1.432 0.000 0.000
2 1.383 -0.181 0.047 0.000 0.000
3 5.437 0.181 0.646 0.000 0.000
4 1.327 0.062 0.044 0.000 0.000
5 6.695 -0.002 0.236 0.000 0.000
6 0.003 0.000 0.367 0.000 0.000
7 0.063 2.269 -0.029 0.000 0.000
8 0.063 -2.269 -0.029 0.000 0.000
9 4.213 0.000 2.958 0.000 0.000
10 -4.790 0.000 -10.330 0.000 0.000
11 64.337 0.004 2.005 0.000 0.000
12 68.073 -0.288 2.356 0.000 0.000
13 65.969 0.392 3.006 0.000 0.000
14 63.229 -0.179 2.590 0.000 0.000
15 61.914 0.246 2.996 0.000 0.000
16 55.201 1.819 2.283 0.000 0.000
17 55.201 -1.812 2.283 0.000 0.000
18 58.521 0.003 4.672 0.000 0.000
19 51.319 0.003 -5.958 0.000 0.000
20 63.326 3.452 2.139 0.000 0.000
21 62.012 3.877 2.545 0.000 0.000
22 63.326 -3.810 2.139 0.000 0.000
23 62.012 -3.385 2.545 0.000 0.000
24 69.967 -0.179 6.918 0.000 0.000
25 68.652 0.246 7.324 0.000 0.000
26 55.562 -0.179 -14.342 0.000 0.000
27 54.248 0.246 -13.935 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 17.910 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 15.500 ft Governing Load Case : # 10

Width (W2) = 15.500 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 240.250 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 32 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

24 0.4304 0.4298 0.4521 0.4527 0.000

24 0.4304 0.4298 0.4521 0.4527 0.000

24 0.4304 0.4298 0.4521 0.4527 0.000

24 0.4304 0.4298 0.4521 0.4527 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

24 0.4304 0.4298 0.4521 0.4527

24 0.4304 0.4298 0.4521 0.4527

24 0.4304 0.4298 0.4521 0.4527

24 0.4304 0.4298 0.4521 0.4527

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 14222.504 28.619 443.596 220448.806

2 103.456 397.260 6157.527 1603.576

3 114.712 32.124 497.922 1778.032

4 301.238 421.326 6530.553 4669.185

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 33 of 352

5 13726.466 90.464 1402.187 212760.226

6 N/A 49.096 760.993 N/A

7 7.954 614.649 9527.066 123.290

8 7.954 614.654 9527.140 123.290

9 N/A 6.805 105.474 N/A

10 N/A 1.512 23.444 N/A

11 12437.036 25.025 387.890 192774.065

12 180.501 22.097 342.503 2797.758

13 130.135 16.966 262.966 2017.089

14 277.360 19.167 297.088 4299.085

15 198.886 16.347 253.371 3082.726

16 25.081 19.984 309.758 388.758

17 25.177 19.984 309.758 390.242

18 13668.878 10.119 156.848 211867.602

19 12627.763 7.331 113.638 195730.332

20 14.393 23.229 360.048 223.088

21 12.645 19.260 298.534 195.994

22 13.041 23.229 360.048 202.130

23 14.485 19.260 298.534 224.514

24 296.187 7.662 118.756 4590.893

25 212.566 7.147 110.773 3294.775

26 255.939 3.193 49.498 3967.051

27 183.319 3.239 50.211 2841.440

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 2.269 kip
Governing Restoring Force : 18.050 kip
Minimum Sliding Ratio for the Critical Load Case : 7.954
Critical Load Case for Overturning about X-Direction : 10
Governing Overturning Moment : -10.330 kip-ft
Governing Resisting Moment : 242.170 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 23.444

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -10.330 kip
Governing Restoring Force : 15.624 kip
Minimum Sliding Ratio for the Critical Load Case : 1.512
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -2.269 kip-ft
Governing Resisting Moment : 279.777 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 123.290

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 34 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 68.417 kip, Load Case # 24

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 188.219 kip

Distance along X to design for shear,


Dx = 9.237 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 141.164 kip

Critical load case for Vux is # 24 28.916 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 35 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 188.219 kip

Distance along X to design for shear, Dz = 6.263 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 141.164 kip

Critical load case for Vuz is # 24 28.288 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 24

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 36 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 6.930 ft
a distance, Dx =

Ultimate moment, 108.461 kip-ft

Nominal moment capacity, Mn = 120.512 kip-ft

Required = 0.00206

Since OK

Area of Steel Required, As = 3.069 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 6.653 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 6.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


6.680 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 28

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 3.080 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00188

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 6.653 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 37 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 24

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 6.930 ft
a distance, Dz =

Ultimate moment, 111.299 kip-ft

Nominal moment capacity, Mn = 123.666 kip-ft

Required = 0.00234

Since OK

Area of Steel Required, As = 3.312 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 11.219 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 11.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 38 of 352

Available development length for bars, DL


6.680 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 17

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 3.400 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00229

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 11.219 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 6.930 ft
at a distance, Dx =

Ultimate moment, 55.825 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 39 of 352

Nominal moment capacity, Mn = 62.028 kip-ft

Required = 0.00116

Since OK

Area of Steel Required, As = 2.553 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 14.958 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 6.930 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 40 of 352

Ultimate moment, 55.825 kip-ft

Nominal moment capacity, Mn = 62.028 kip-ft

Required = 0.00105

Since OK

Area of Steel Required, As = 2.678 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.484 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 32

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 41 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 42 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 43 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 42.189 -0.346 0.271 0.000 0.000
2 3.509 -0.154 0.068 0.000 0.000
3 0.236 -0.078 -0.019 0.000 0.000
4 3.539 0.064 0.028 0.000 0.000
5 2.408 -0.015 0.025 0.000 0.000
6 -0.027 -0.012 -0.040 0.000 0.000
7 -0.434 2.179 0.047 0.000 0.000
8 0.444 -2.269 -0.000 0.000 0.000
9 1.042 -0.081 0.849 0.000 0.000
10 -1.165 0.096 -7.809 0.000 0.000
11 59.065 -0.484 0.380 0.000 0.000
12 60.081 -0.692 0.454 0.000 0.000
13 56.654 -0.445 0.320 0.000 0.000
14 56.501 -0.603 0.355 0.000 0.000
15 54.360 -0.449 0.271 0.000 0.000
16 50.238 1.309 0.300 0.000 0.000
17 50.940 -2.249 0.262 0.000 0.000
18 51.418 -0.499 0.941 0.000 0.000
19 49.653 -0.358 -5.985 0.000 0.000
20 55.837 2.896 0.474 0.000 0.000
21 53.695 3.051 0.390 0.000 0.000
22 57.241 -4.220 0.398 0.000 0.000
23 55.099 -4.066 0.314 0.000 0.000
24 58.198 -0.719 1.756 0.000 0.000
25 56.056 -0.565 1.672 0.000 0.000
26 54.667 -0.437 -12.096 0.000 0.000
27 52.525 -0.283 -12.180 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 42.189 -0.346 0.271 0.000 0.000
2 3.509 -0.154 0.068 0.000 0.000
3 0.236 -0.078 -0.019 0.000 0.000
4 3.539 0.064 0.028 0.000 0.000
5 2.408 -0.015 0.025 0.000 0.000
6 -0.027 -0.012 -0.040 0.000 0.000
7 -0.434 2.179 0.047 0.000 0.000
8 0.444 -2.269 -0.000 0.000 0.000
9 1.042 -0.081 0.849 0.000 0.000
10 -1.165 0.096 -7.809 0.000 0.000
11 59.065 -0.484 0.380 0.000 0.000
12 60.081 -0.692 0.454 0.000 0.000
13 56.654 -0.445 0.320 0.000 0.000
14 56.501 -0.603 0.355 0.000 0.000
15 54.360 -0.449 0.271 0.000 0.000
16 50.238 1.309 0.300 0.000 0.000
17 50.940 -2.249 0.262 0.000 0.000
18 51.418 -0.499 0.941 0.000 0.000
19 49.653 -0.358 -5.985 0.000 0.000
20 55.837 2.896 0.474 0.000 0.000
21 53.695 3.051 0.390 0.000 0.000
22 57.241 -4.220 0.398 0.000 0.000
23 55.099 -4.066 0.314 0.000 0.000
24 58.198 -0.719 1.756 0.000 0.000
25 56.056 -0.565 1.672 0.000 0.000
26 54.667 -0.437 -12.096 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 44 of 352

27 52.525 -0.283 -12.180 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 15.438 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 12.833 ft Governing Load Case : # 10

Width (W2) = 12.833 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 164.694 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

26 0.5175 0.5150 0.4463 0.4488 0.000

26 0.5175 0.5150 0.4463 0.4488 0.000

12 0.5155 0.5115 0.5141 0.5181 0.000

12 0.5155 0.5115 0.5141 0.5181 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

26 0.5175 0.5150 0.4463 0.4488

26 0.5175 0.5150 0.4463 0.4488

12 0.5155 0.5115 0.5141 0.5181

12 0.5155 0.5115 0.5141 0.5181

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 45 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 96.650 123.300 1582.348 1240.346

2 91.822 207.732 2665.891 1178.381

3 159.147 657.740 8440.995 2042.384

4 221.966 509.037 6532.638 2848.563

5 880.631 549.163 7047.597 11301.434

6 1047.155 312.317 4008.062 13438.486

7 5.569 258.169 3313.165 71.471

8 5.542 34356.178 440904.286 71.122

9 159.705 15.168 194.656 2049.547

10 123.010 1.507 19.342 1578.635

11 86.452 110.290 1415.386 1109.470

12 61.296 93.394 1198.555 786.636

13 91.467 127.195 1632.338 1173.830

14 67.318 114.407 1468.227 863.918

15 88.072 145.827 1871.445 1130.257

16 28.624 124.941 1603.413 367.336

17 16.816 144.352 1852.517 215.801

18 76.335 40.436 518.932 979.631

19 103.972 6.212 79.719 1334.307

20 13.904 85.037 1091.313 178.439

21 12.850 100.575 1290.717 164.909

22 9.708 103.006 1321.906 124.590

23 9.813 127.091 1631.003 125.937

24 57.639 23.602 302.888 739.696

25 71.486 24.144 309.849 917.407

26 90.793 3.281 42.103 1165.176

27 136.538 3.170 40.685 1752.242

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -2.269 kip
Governing Restoring Force : 12.574 kip
Minimum Sliding Ratio for the Critical Load Case : 5.542

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 46 of 352

Critical Load Case for Overturning about X-Direction : 10


Governing Overturning Moment : -7.809 kip-ft
Governing Resisting Moment : 151.043 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 19.342

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -7.809 kip
Governing Restoring Force : 11.770 kip
Minimum Sliding Ratio for the Critical Load Case : 1.507
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 2.269 kip-ft
Governing Resisting Moment : 161.366 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 71.122

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 58.139 kip, Load Case # 12

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 47 of 352

From ACI Cl.11.3.1.1, Vc = 155.837 kip

Distance along X to design for shear,


Dx = 7.904 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 116.878 kip

Critical load case for Vux is # 12 23.130 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 155.837 kip

Distance along X to design for shear, Dz = 4.930 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 116.878 kip

Critical load case for Vuz is # 12 23.156 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 48 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 12

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.596 ft
a distance, Dx =

Ultimate moment, 73.595 kip-ft

Nominal moment capacity, Mn = 81.772 kip-ft

Required = 0.00168

Since OK

Area of Steel Required, As = 2.218 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 7.381 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 49 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.346 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 21

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.310 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00170

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 7.381 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 12

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.596 ft
a distance, Dz =

Ultimate moment, 73.499 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 50 of 352

Nominal moment capacity, Mn = 81.665 kip-ft

Required = 0.00185

Since OK

Area of Steel Required, As = 2.178 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 14.750 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.346 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00179

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 14.750 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 51 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.596 ft
at a distance, Dx =

Ultimate moment, 30.146 kip-ft

Nominal moment capacity, Mn = 33.495 kip-ft

Required = 0.00075

Since OK

Area of Steel Required, As = 2.114 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 52 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.596 ft
at a distance, Dx =

Ultimate moment, 30.146 kip-ft

Nominal moment capacity, Mn = 33.495 kip-ft

Required = 0.00068

Since OK

Area of Steel Required, As = 2.218 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.381 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 33

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 53 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 54 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 55 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 41.295 1.383 1.029 0.000 0.000
2 1.399 0.315 0.095 0.000 0.000
3 2.473 0.119 0.184 0.000 0.000
4 1.343 -0.119 0.003 0.000 0.000
5 1.664 -0.012 -0.086 0.000 0.000
6 0.402 -0.030 0.293 0.000 0.000
7 2.779 1.676 -0.033 0.000 0.000
8 -2.978 -3.815 -0.198 0.000 0.000
9 4.094 0.102 2.114 0.000 0.000
10 -4.197 -0.117 -4.192 0.000 0.000
11 57.813 1.937 1.441 0.000 0.000
12 54.655 2.130 1.396 0.000 0.000
13 55.860 1.644 1.681 0.000 0.000
14 53.260 1.915 1.713 0.000 0.000
15 54.013 1.611 1.891 0.000 0.000
16 52.420 2.953 1.677 0.000 0.000
17 47.815 -1.440 1.545 0.000 0.000
18 53.472 1.694 3.395 0.000 0.000
19 46.840 1.518 -1.650 0.000 0.000
20 57.263 4.630 1.338 0.000 0.000
21 58.016 4.326 1.516 0.000 0.000
22 48.054 -4.156 1.073 0.000 0.000
23 48.806 -4.459 1.251 0.000 0.000
24 59.368 2.112 4.773 0.000 0.000
25 60.121 1.808 4.951 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 56 of 352

26 46.103 1.760 -5.317 0.000 0.000


27 46.856 1.457 -5.139 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 41.295 1.383 1.029 0.000 0.000
2 1.399 0.315 0.095 0.000 0.000
3 2.473 0.119 0.184 0.000 0.000
4 1.343 -0.119 0.003 0.000 0.000
5 1.664 -0.012 -0.086 0.000 0.000
6 0.402 -0.030 0.293 0.000 0.000
7 2.779 1.676 -0.033 0.000 0.000
8 -2.978 -3.815 -0.198 0.000 0.000
9 4.094 0.102 2.114 0.000 0.000
10 -4.197 -0.117 -4.192 0.000 0.000
11 57.813 1.937 1.441 0.000 0.000
12 54.655 2.130 1.396 0.000 0.000
13 55.860 1.644 1.681 0.000 0.000
14 53.260 1.915 1.713 0.000 0.000
15 54.013 1.611 1.891 0.000 0.000
16 52.420 2.953 1.677 0.000 0.000
17 47.815 -1.440 1.545 0.000 0.000
18 53.472 1.694 3.395 0.000 0.000
19 46.840 1.518 -1.650 0.000 0.000
20 57.263 4.630 1.338 0.000 0.000
21 58.016 4.326 1.516 0.000 0.000
22 48.054 -4.156 1.073 0.000 0.000
23 48.806 -4.459 1.251 0.000 0.000
24 59.368 2.112 4.773 0.000 0.000
25 60.121 1.808 4.951 0.000 0.000
26 46.103 1.760 -5.317 0.000 0.000
27 46.856 1.457 -5.139 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 15.448 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 10.667 ft Governing Load Case : # 10

Width (W2) = 10.667 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 113.778 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 57 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

25 0.6450 0.6629 0.7118 0.6939 0.000

21 0.6310 0.6738 0.6888 0.6460 0.000

25 0.6450 0.6629 0.7118 0.6939 0.000

25 0.6450 0.6629 0.7118 0.6939 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

25 0.6450 0.6629 0.7118 0.6939

21 0.6310 0.6738 0.6888 0.6460

25 0.6450 0.6629 0.7118 0.6939

25 0.6450 0.6629 0.7118 0.6939

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 21.093 28.352 302.421 224.988

2 29.273 97.099 1035.725 312.246

3 82.432 53.014 565.483 879.275

4 77.189 3408.089 36352.947 823.347

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 58 of 352

5 751.924 108.668 1159.126 8020.527

6 290.414 29.813 318.005 3097.747

7 5.920 300.692 3207.387 63.149

8 1.847 35.550 379.197 19.697

9 103.364 5.005 53.389 1102.544

10 54.859 1.535 16.374 585.161

11 19.330 25.983 277.153 206.190

12 16.837 25.692 274.045 179.599

13 22.180 21.695 231.410 236.590

14 18.362 20.530 218.991 195.863

15 22.056 18.796 200.490 235.269

16 11.766 20.712 220.930 125.503

17 22.530 20.993 223.927 240.319

18 20.821 10.389 110.815 222.093

19 21.047 19.369 206.598 224.500

20 8.027 27.783 296.356 85.626

21 8.678 24.768 264.187 92.565

22 7.835 30.333 323.553 83.572

23 7.386 26.318 280.722 78.781

24 18.097 8.008 85.414 193.031

25 21.344 7.796 83.153 227.672

26 17.942 5.941 63.367 191.381

27 21.941 6.220 66.345 234.034

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -3.815 kip
Governing Restoring Force : 7.045 kip
Minimum Sliding Ratio for the Critical Load Case : 1.847
Critical Load Case for Overturning about X-Direction : 10
Governing Overturning Moment : -4.192 kip-ft
Governing Resisting Moment : 68.639 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 16.374

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -4.192 kip
Governing Restoring Force : 6.435 kip
Minimum Sliding Ratio for the Critical Load Case : 1.535
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 3.815 kip-ft
Governing Resisting Moment : 75.141 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 19.697

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 59 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 57.308 kip, Load Case # 25

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 129.527 kip

Distance along X to design for shear,


Dx = 6.820 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 97.145 kip

Critical load case for Vux is # 25 22.322 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 60 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 129.527 kip

Distance along X to design for shear, Dz = 6.820 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 97.145 kip

Critical load case for Vuz is # 25 21.914 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 25

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 61 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 4.513 ft
a distance, Dx =

Ultimate moment, 58.099 kip-ft

Nominal moment capacity, Mn = 64.554 kip-ft

Required = 0.00160

Since OK

Area of Steel Required, As = 1.843 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 7.602 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


4.263 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 17

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.870 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00166

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 7.602 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 62 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 25

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 4.513 ft
a distance, Dz =

Ultimate moment, 59.312 kip-ft

Nominal moment capacity, Mn = 65.902 kip-ft

Required = 0.00180

Since OK

Area of Steel Required, As = 1.757 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 8.108 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 8.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 63 of 352

Available development length for bars, DL


4.263 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 16

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.760 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00172

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 8.108 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 4.513 ft
at a distance, Dx =

Ultimate moment, 16.295 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 64 of 352

Nominal moment capacity, Mn = 18.105 kip-ft

Required = 0.00052

Since OK

Area of Steel Required, As = 1.699 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 4.513 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 65 of 352

Ultimate moment, 16.295 kip-ft

Nominal moment capacity, Mn = 18.105 kip-ft

Required = 0.00044

Since OK

Area of Steel Required, As = 1.843 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 18 in o.c.

Isolated Footing 34

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 66 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 67 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 68 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 42.453 -0.231 0.125 0.000 0.000
2 1.451 0.003 0.260 0.000 0.000
3 2.984 -0.106 -0.267 0.000 0.000
4 1.512 0.009 -0.058 0.000 0.000
5 2.326 0.002 0.092 0.000 0.000
6 0.928 0.411 0.393 0.000 0.000
7 -14.547 7.489 -0.243 0.000 0.000
8 14.203 -3.350 -0.053 0.000 0.000
9 0.050 -0.019 2.566 0.000 0.000
10 -0.052 0.012 -2.624 0.000 0.000
11 59.434 -0.323 0.175 0.000 0.000
12 57.450 -0.063 0.910 0.000 0.000
13 58.601 -0.227 -0.173 0.000 0.000
14 56.205 0.386 1.131 0.000 0.000
15 56.924 0.284 0.454 0.000 0.000
16 40.790 6.372 0.585 0.000 0.000
17 63.790 -2.299 0.737 0.000 0.000
18 52.468 0.366 2.832 0.000 0.000
19 52.386 0.390 -1.319 0.000 0.000
20 31.909 11.915 0.309 0.000 0.000
21 32.628 11.813 -0.367 0.000 0.000
22 77.908 -5.426 0.614 0.000 0.000
23 78.628 -5.528 -0.063 0.000 0.000
24 55.264 -0.097 4.804 0.000 0.000
25 55.984 -0.199 4.127 0.000 0.000
26 55.101 -0.048 -3.499 0.000 0.000
27 55.820 -0.150 -4.176 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 42.453 -0.231 0.125 0.000 0.000
2 1.451 0.003 0.260 0.000 0.000
3 2.984 -0.106 -0.267 0.000 0.000
4 1.512 0.009 -0.058 0.000 0.000
5 2.326 0.002 0.092 0.000 0.000
6 0.928 0.411 0.393 0.000 0.000
7 -14.547 7.489 -0.243 0.000 0.000
8 14.203 -3.350 -0.053 0.000 0.000
9 0.050 -0.019 2.566 0.000 0.000
10 -0.052 0.012 -2.624 0.000 0.000
11 59.434 -0.323 0.175 0.000 0.000
12 57.450 -0.063 0.910 0.000 0.000
13 58.601 -0.227 -0.173 0.000 0.000
14 56.205 0.386 1.131 0.000 0.000
15 56.924 0.284 0.454 0.000 0.000
16 40.790 6.372 0.585 0.000 0.000
17 63.790 -2.299 0.737 0.000 0.000
18 52.468 0.366 2.832 0.000 0.000
19 52.386 0.390 -1.319 0.000 0.000
20 31.909 11.915 0.309 0.000 0.000
21 32.628 11.813 -0.367 0.000 0.000
22 77.908 -5.426 0.614 0.000 0.000
23 78.628 -5.528 -0.063 0.000 0.000
24 55.264 -0.097 4.804 0.000 0.000
25 55.984 -0.199 4.127 0.000 0.000
26 55.101 -0.048 -3.499 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 69 of 352

27 55.820 -0.150 -4.176 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 20.075 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 15.833 ft Governing Load Case : #7

Width (W2) = 15.833 ft Governing Load Case : #7

Depth (D2) = 1.000 ft Governing Load Case : #7

Area (A2) = 250.694 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

23 0.4721 0.4554 0.4552 0.4719 0.000

23 0.4721 0.4554 0.4552 0.4719 0.000

23 0.4721 0.4554 0.4552 0.4719 0.000

23 0.4721 0.4554 0.4552 0.4719 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

23 0.4721 0.4554 0.4552 0.4719

23 0.4721 0.4554 0.4552 0.4719

23 0.4721 0.4554 0.4552 0.4719

23 0.4721 0.4554 0.4552 0.4719

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 70 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 173.385 319.648 5061.100 2745.260

2 6156.511 75.150 1189.879 97478.087

3 192.057 75.989 1203.160 3040.905

4 2279.979 337.916 5350.332 36099.671

5 10950.573 216.972 3435.386 173384.075

6 46.856 48.996 775.768 741.879

7 1.539 47.388 750.314 24.375

8 7.733 488.241 7730.486 122.439

9 995.709 7.338 116.188 15765.395

10 1622.052 7.157 113.316 25682.497

11 150.116 276.750 4381.876 2376.834

12 748.961 52.236 827.067 11858.557

13 212.103 278.007 4401.773 3358.290

14 121.564 41.461 656.473 1924.765

15 166.564 103.997 1646.618 2637.265

16 6.152 67.027 1061.265 97.403

17 22.052 68.791 1089.191 349.163

18 123.144 15.903 251.798 1949.776

19 115.341 34.103 539.965 1826.227

20 2.917 112.300 1778.076 46.185

21 2.973 95.605 1513.739 47.066

22 10.644 94.088 1489.725 168.535

23 10.513 923.226 14617.737 166.452

24 480.151 9.666 153.049 7602.389

25 235.394 11.339 179.528 3727.066

26 967.009 13.248 209.757 15310.976

27 311.380 11.187 177.123 4930.179

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 7.489 kip
Governing Restoring Force : 11.528 kip
Minimum Sliding Ratio for the Critical Load Case : 1.539

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 71 of 352

Critical Load Case for Overturning about X-Direction : 10


Governing Overturning Moment : -2.624 kip-ft
Governing Resisting Moment : 297.285 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 113.316

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -2.624 kip
Governing Restoring Force : 18.776 kip
Minimum Sliding Ratio for the Critical Load Case : 7.157
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -7.489 kip-ft
Governing Resisting Moment : 182.534 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 24.375

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 76.958 kip, Load Case # 23

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 72 of 352

From ACI Cl.11.3.1.1, Vc = 192.266 kip

Distance along X to design for shear,


Dx = 6.430 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 144.200 kip

Critical load case for Vux is # 23 31.936 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 192.266 kip

Distance along X to design for shear, Dz = 6.430 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 144.200 kip

Critical load case for Vuz is # 23 32.435 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 73 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 23

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 7.096 ft
a distance, Dx =

Ultimate moment, 127.377 kip-ft

Nominal moment capacity, Mn = 141.530 kip-ft

Required = 0.00238

Since OK

Area of Steel Required, As = 3.614 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 5.738 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 5.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 74 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


6.846 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 33

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 3.630 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00217

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 5.738 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 23

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 7.096 ft
a distance, Dz =

Ultimate moment, 125.069 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 75 of 352

Nominal moment capacity, Mn = 138.965 kip-ft

Required = 0.00257

Since OK

Area of Steel Required, As = 3.730 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 5.564 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 5.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


6.846 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 34

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 3.740 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00246

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 5.564 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 76 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 7.096 ft
at a distance, Dx =

Ultimate moment, 59.802 kip-ft

Nominal moment capacity, Mn = 66.447 kip-ft

Required = 0.00122

Since OK

Area of Steel Required, As = 2.608 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 77 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 7.096 ft
at a distance, Dx =

Ultimate moment, 59.802 kip-ft

Nominal moment capacity, Mn = 66.447 kip-ft

Required = 0.00110

Since OK

Area of Steel Required, As = 2.736 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.651 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 35

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 78 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 79 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 80 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 42.482 0.238 0.119 0.000 0.000
2 3.019 0.110 0.258 0.000 0.000
3 1.425 -0.005 -0.266 0.000 0.000
4 2.403 -0.001 -0.059 0.000 0.000
5 1.471 0.001 0.089 0.000 0.000
6 0.928 -0.411 0.393 0.000 0.000
7 14.203 3.350 -0.053 0.000 0.000
8 -14.547 -7.489 -0.243 0.000 0.000
9 0.050 0.019 2.566 0.000 0.000
10 -0.052 -0.012 -2.624 0.000 0.000
11 59.474 0.334 0.167 0.000 0.000
12 58.625 0.258 0.895 0.000 0.000
13 57.566 0.071 -0.181 0.000 0.000
14 56.952 -0.261 1.119 0.000 0.000
15 56.290 -0.378 0.447 0.000 0.000
16 63.825 2.308 0.730 0.000 0.000
17 40.825 -6.363 0.577 0.000 0.000
18 52.503 -0.357 2.825 0.000 0.000
19 52.421 -0.381 -1.327 0.000 0.000
20 78.655 5.551 0.602 0.000 0.000
21 77.994 5.434 -0.070 0.000 0.000
22 32.656 -11.790 0.297 0.000 0.000
23 31.994 -11.907 -0.375 0.000 0.000
24 56.011 0.222 4.792 0.000 0.000
25 55.350 0.105 4.119 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 81 of 352

26 55.848 0.173 -3.511 0.000 0.000


27 55.186 0.056 -4.183 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 42.482 0.238 0.119 0.000 0.000
2 3.019 0.110 0.258 0.000 0.000
3 1.425 -0.005 -0.266 0.000 0.000
4 2.403 -0.001 -0.059 0.000 0.000
5 1.471 0.001 0.089 0.000 0.000
6 0.928 -0.411 0.393 0.000 0.000
7 14.203 3.350 -0.053 0.000 0.000
8 -14.547 -7.489 -0.243 0.000 0.000
9 0.050 0.019 2.566 0.000 0.000
10 -0.052 -0.012 -2.624 0.000 0.000
11 59.474 0.334 0.167 0.000 0.000
12 58.625 0.258 0.895 0.000 0.000
13 57.566 0.071 -0.181 0.000 0.000
14 56.952 -0.261 1.119 0.000 0.000
15 56.290 -0.378 0.447 0.000 0.000
16 63.825 2.308 0.730 0.000 0.000
17 40.825 -6.363 0.577 0.000 0.000
18 52.503 -0.357 2.825 0.000 0.000
19 52.421 -0.381 -1.327 0.000 0.000
20 78.655 5.551 0.602 0.000 0.000
21 77.994 5.434 -0.070 0.000 0.000
22 32.656 -11.790 0.297 0.000 0.000
23 31.994 -11.907 -0.375 0.000 0.000
24 56.011 0.222 4.792 0.000 0.000
25 55.350 0.105 4.119 0.000 0.000
26 55.848 0.173 -3.511 0.000 0.000
27 55.186 0.056 -4.183 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 20.082 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 15.833 ft Governing Load Case : #8

Width (W2) = 15.833 ft Governing Load Case : #8

Depth (D2) = 1.000 ft Governing Load Case : #8

Area (A2) = 250.694 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 82 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

20 0.4544 0.4712 0.4731 0.4563 0.000

20 0.4544 0.4712 0.4731 0.4563 0.000

20 0.4544 0.4712 0.4731 0.4563 0.000

20 0.4544 0.4712 0.4731 0.4563 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

20 0.4544 0.4712 0.4731 0.4563

20 0.4544 0.4712 0.4731 0.4563

20 0.4544 0.4712 0.4731 0.4563

20 0.4544 0.4712 0.4731 0.4563

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 167.972 336.287 5324.549 2659.563

2 184.779 78.685 1245.847 2925.673

3 3686.639 73.309 1160.728 58371.787

4 23171.688 339.700 5378.581 366885.066

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 83 of 352

5 19778.468 219.369 3473.336 313159.079

6 46.856 48.996 775.768 741.879

7 7.733 488.241 7730.485 122.439

8 1.539 47.388 750.314 24.375

9 995.709 7.338 116.188 15765.395

10 1622.052 7.157 113.316 25682.497

11 145.438 291.172 4610.226 2302.767

12 186.537 53.758 851.176 2953.508

13 673.747 263.432 4171.010 10667.654

14 181.206 42.241 668.824 2869.099

15 124.207 105.039 1663.112 1966.616

16 21.974 69.511 1100.587 347.915

17 6.163 67.914 1075.308 97.584

18 126.309 15.951 252.552 1999.893

19 118.119 33.926 537.165 1870.210

20 10.472 96.592 1529.375 165.807

21 10.637 820.154 12985.770 168.415

22 2.980 118.104 1869.975 47.176

23 2.922 92.840 1469.965 46.272

24 211.186 9.768 154.668 3343.784

25 444.437 11.282 178.637 7036.923

26 270.298 13.309 210.722 4279.716

27 831.439 11.091 175.604 13164.446

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -7.489 kip
Governing Restoring Force : 11.528 kip
Minimum Sliding Ratio for the Critical Load Case : 1.539
Critical Load Case for Overturning about X-Direction : 10
Governing Overturning Moment : -2.624 kip-ft
Governing Resisting Moment : 297.285 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 113.316

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -2.624 kip
Governing Restoring Force : 18.776 kip
Minimum Sliding Ratio for the Critical Load Case : 7.157
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 7.489 kip-ft
Governing Resisting Moment : 182.534 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 24.375

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 84 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 76.985 kip, Load Case # 20

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 192.266 kip

Distance along X to design for shear,


Dx = 9.404 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 144.200 kip

Critical load case for Vux is # 20 31.996 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 85 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 192.266 kip

Distance along X to design for shear, Dz = 9.404 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 144.200 kip

Critical load case for Vuz is # 20 32.449 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 20

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 86 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 7.096 ft
a distance, Dx =

Ultimate moment, 127.433 kip-ft

Nominal moment capacity, Mn = 141.593 kip-ft

Required = 0.00238

Since OK

Area of Steel Required, As = 3.616 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 5.738 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 5.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


6.846 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 33

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 3.630 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00217

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 5.738 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 87 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 20

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 7.096 ft
a distance, Dz =

Ultimate moment, 125.341 kip-ft

Nominal moment capacity, Mn = 139.268 kip-ft

Required = 0.00258

Since OK

Area of Steel Required, As = 3.738 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 5.564 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 5.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 88 of 352

Available development length for bars, DL


6.846 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 34

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 3.740 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00246

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 5.564 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 7.096 ft
at a distance, Dx =

Ultimate moment, 59.802 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 89 of 352

Nominal moment capacity, Mn = 66.447 kip-ft

Required = 0.00122

Since OK

Area of Steel Required, As = 2.608 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 7.096 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 90 of 352

Ultimate moment, 59.802 kip-ft

Nominal moment capacity, Mn = 66.447 kip-ft

Required = 0.00110

Since OK

Area of Steel Required, As = 2.736 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.651 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 36

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 91 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 92 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 93 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 44.867 -0.963 0.054 0.000 0.000
2 3.412 -0.201 -0.150 0.000 0.000
3 1.741 -0.065 0.157 0.000 0.000
4 3.345 -0.070 0.097 0.000 0.000
5 1.695 -0.027 -0.088 0.000 0.000
6 18.044 -5.187 0.344 0.000 0.000
7 -13.588 12.058 -0.210 0.000 0.000
8 4.829 -1.122 -0.064 0.000 0.000
9 -0.445 0.261 2.787 0.000 0.000
10 0.289 -0.232 -2.776 0.000 0.000
11 62.814 -1.349 0.075 0.000 0.000
12 71.034 -4.114 -0.146 0.000 0.000
13 71.000 -3.965 0.643 0.000 0.000
14 87.818 -9.683 0.375 0.000 0.000
15 87.797 -9.590 0.868 0.000 0.000
16 71.841 0.191 0.447 0.000 0.000
17 86.574 -10.353 0.563 0.000 0.000
18 82.355 -9.246 2.844 0.000 0.000
19 82.943 -9.641 -1.606 0.000 0.000
20 46.230 15.315 -0.338 0.000 0.000
21 46.209 15.408 0.155 0.000 0.000
22 75.696 -5.773 -0.105 0.000 0.000
23 75.675 -5.680 0.388 0.000 0.000
24 67.257 -3.560 4.456 0.000 0.000
25 67.236 -3.466 4.949 0.000 0.000
26 68.433 -4.349 -4.443 0.000 0.000
27 68.412 -4.256 -3.951 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 44.867 -0.963 0.054 0.000 0.000
2 3.412 -0.201 -0.150 0.000 0.000
3 1.741 -0.065 0.157 0.000 0.000
4 3.345 -0.070 0.097 0.000 0.000
5 1.695 -0.027 -0.088 0.000 0.000
6 18.044 -5.187 0.344 0.000 0.000
7 -13.588 12.058 -0.210 0.000 0.000
8 4.829 -1.122 -0.064 0.000 0.000
9 -0.445 0.261 2.787 0.000 0.000
10 0.289 -0.232 -2.776 0.000 0.000
11 62.814 -1.349 0.075 0.000 0.000
12 71.034 -4.114 -0.146 0.000 0.000
13 71.000 -3.965 0.643 0.000 0.000
14 87.818 -9.683 0.375 0.000 0.000
15 87.797 -9.590 0.868 0.000 0.000
16 71.841 0.191 0.447 0.000 0.000
17 86.574 -10.353 0.563 0.000 0.000
18 82.355 -9.246 2.844 0.000 0.000
19 82.943 -9.641 -1.606 0.000 0.000
20 46.230 15.315 -0.338 0.000 0.000
21 46.209 15.408 0.155 0.000 0.000
22 75.696 -5.773 -0.105 0.000 0.000
23 75.675 -5.680 0.388 0.000 0.000
24 67.257 -3.560 4.456 0.000 0.000
25 67.236 -3.466 4.949 0.000 0.000
26 68.433 -4.349 -4.443 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 94 of 352

27 68.412 -4.256 -3.951 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 22.373 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 18.333 ft Governing Load Case : #7

Width (W2) = 18.333 ft Governing Load Case : #7

Depth (D2) = 1.000 ft Governing Load Case : #7

Area (A2) = 336.111 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

14 0.4203 0.4015 0.4022 0.4211 0.000

14 0.4203 0.4015 0.4022 0.4211 0.000

15 0.4197 0.4010 0.4027 0.4214 0.000

15 0.4197 0.4010 0.4027 0.4214 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

14 0.4203 0.4015 0.4022 0.4211

14 0.4203 0.4015 0.4022 0.4211

15 0.4197 0.4010 0.4027 0.4214

15 0.4197 0.4010 0.4027 0.4214

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 95 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 49.461 885.636 16236.662 906.778

2 133.980 178.914 3280.094 2456.307

3 401.533 166.486 3052.238 7361.438

4 383.837 276.072 5061.326 7037.011

5 955.436 294.747 5403.697 17516.322

6 6.599 99.635 1826.646 120.985

7 1.527 87.863 1610.820 27.998

8 24.613 432.082 7921.507 451.240

9 95.641 8.966 164.381 1753.415

10 109.270 9.134 167.463 2003.284

11 41.983 751.746 13782.018 769.694

12 14.759 416.496 7635.756 270.583

13 15.310 94.451 1731.605 280.678

14 7.138 184.111 3375.374 130.860

15 7.206 79.593 1459.202 132.111

16 319.580 136.883 2509.526 5858.968

17 6.616 121.640 2230.071 121.294

18 7.180 23.346 428.011 131.630

19 6.916 41.514 761.083 126.801

20 3.155 143.038 2622.370 57.846

21 3.135 311.672 5713.989 57.484

22 10.922 601.750 11032.079 200.241

23 11.100 162.466 2978.548 203.493

24 16.529 13.204 242.066 303.036

25 16.971 11.887 217.921 311.126

26 13.665 13.374 245.184 250.519

27 13.961 15.039 275.723 255.959

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 12.058 kip
Governing Restoring Force : 18.415 kip
Minimum Sliding Ratio for the Critical Load Case : 1.527

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 96 of 352

Critical Load Case for Overturning about X-Direction : 9


Governing Overturning Moment : 2.787 kip-ft
Governing Resisting Moment : 458.069 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 164.381

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 2.787 kip
Governing Restoring Force : 24.986 kip
Minimum Sliding Ratio for the Critical Load Case : 8.966
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -12.058 kip-ft
Governing Resisting Moment : 337.599 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 27.998

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 86.427 kip, Load Case # 14

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 97 of 352

From ACI Cl.11.3.1.1, Vc = 222.624 kip

Distance along X to design for shear,


Dx = 10.654 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 166.968 kip

Critical load case for Vux is # 15 36.847 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 222.624 kip

Distance along X to design for shear, Dz = 7.680 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 166.968 kip

Critical load case for Vuz is # 14 37.558 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 98 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 14

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 8.346 ft
a distance, Dx =

Ultimate moment, 171.038 kip-ft

Nominal moment capacity, Mn = 190.042 kip-ft

Required = 0.00277

Since OK

Area of Steel Required, As = 4.870 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 4.855 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 4.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 99 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


8.096 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 45

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 4.950 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00255

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 4.855 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 15

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 8.346 ft
a distance, Dz =

Ultimate moment, 167.183 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 100 of 352

Nominal moment capacity, Mn = 185.759 kip-ft

Required = 0.00298

Since OK

Area of Steel Required, As = 5.004 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 4.747 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 8.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


8.096 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 46

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 5.060 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00288

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 4.747 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 101 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 8.346 ft
at a distance, Dx =

Ultimate moment, 95.787 kip-ft

Nominal moment capacity, Mn = 106.430 kip-ft

Required = 0.00169

Since OK

Area of Steel Required, As = 3.019 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 102 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 8.346 ft
at a distance, Dx =

Ultimate moment, 95.787 kip-ft

Nominal moment capacity, Mn = 106.430 kip-ft

Required = 0.00153

Since OK

Area of Steel Required, As = 3.168 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.629 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 37

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 103 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 104 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 105 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 44.655 0.923 0.047 0.000 0.000
2 1.708 0.049 -0.158 0.000 0.000
3 3.390 0.202 0.162 0.000 0.000
4 1.699 0.023 0.100 0.000 0.000
5 3.317 0.072 -0.094 0.000 0.000
6 18.044 5.187 0.344 0.000 0.000
7 4.829 1.122 -0.064 0.000 0.000
8 -13.588 -12.058 -0.210 0.000 0.000
9 -0.445 -0.261 2.787 0.000 0.000
10 0.289 0.232 -2.776 0.000 0.000
11 62.516 1.292 0.066 0.000 0.000
12 70.647 3.894 -0.175 0.000 0.000
13 70.750 4.061 0.647 0.000 0.000
14 87.481 9.527 0.354 0.000 0.000
15 87.545 9.631 0.868 0.000 0.000
16 86.319 10.304 0.555 0.000 0.000
17 71.586 -0.240 0.439 0.000 0.000
18 82.099 9.197 2.835 0.000 0.000
19 82.687 9.592 -1.614 0.000 0.000
20 75.359 5.617 -0.126 0.000 0.000
21 75.423 5.721 0.388 0.000 0.000
22 45.892 -15.471 -0.359 0.000 0.000
23 45.957 -15.367 0.155 0.000 0.000
24 66.920 3.404 4.435 0.000 0.000
25 66.984 3.508 4.949 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 106 of 352

26 68.095 4.193 -4.465 0.000 0.000


27 68.160 4.297 -3.951 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 44.655 0.923 0.047 0.000 0.000
2 1.708 0.049 -0.158 0.000 0.000
3 3.390 0.202 0.162 0.000 0.000
4 1.699 0.023 0.100 0.000 0.000
5 3.317 0.072 -0.094 0.000 0.000
6 18.044 5.187 0.344 0.000 0.000
7 4.829 1.122 -0.064 0.000 0.000
8 -13.588 -12.058 -0.210 0.000 0.000
9 -0.445 -0.261 2.787 0.000 0.000
10 0.289 0.232 -2.776 0.000 0.000
11 62.516 1.292 0.066 0.000 0.000
12 70.647 3.894 -0.175 0.000 0.000
13 70.750 4.061 0.647 0.000 0.000
14 87.481 9.527 0.354 0.000 0.000
15 87.545 9.631 0.868 0.000 0.000
16 86.319 10.304 0.555 0.000 0.000
17 71.586 -0.240 0.439 0.000 0.000
18 82.099 9.197 2.835 0.000 0.000
19 82.687 9.592 -1.614 0.000 0.000
20 75.359 5.617 -0.126 0.000 0.000
21 75.423 5.721 0.388 0.000 0.000
22 45.892 -15.471 -0.359 0.000 0.000
23 45.957 -15.367 0.155 0.000 0.000
24 66.920 3.404 4.435 0.000 0.000
25 66.984 3.508 4.949 0.000 0.000
26 68.095 4.193 -4.465 0.000 0.000
27 68.160 4.297 -3.951 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 22.304 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 18.333 ft Governing Load Case : #8

Width (W2) = 18.333 ft Governing Load Case : #8

Depth (D2) = 1.000 ft Governing Load Case : #8

Area (A2) = 336.111 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 107 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

14 0.4007 0.4192 0.4199 0.4013 0.000

14 0.4007 0.4192 0.4199 0.4013 0.000

15 0.4002 0.4190 0.4207 0.4019 0.000

15 0.4002 0.4190 0.4207 0.4019 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

14 0.4007 0.4192 0.4199 0.4013

14 0.4007 0.4192 0.4199 0.4013

15 0.4002 0.4190 0.4207 0.4019

15 0.4002 0.4190 0.4207 0.4019

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 51.522 1009.915 18515.101 944.562

2 531.596 165.385 3032.065 9745.924

3 133.015 166.377 3050.245 2438.605

4 1144.527 260.678 4779.101 20982.997

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 108 of 352

5 373.759 284.540 5216.573 6852.241

6 6.599 99.635 1826.645 120.985

7 24.613 432.082 7921.507 451.240

8 1.527 87.863 1610.820 27.998

9 95.641 8.966 164.381 1753.415

10 109.270 9.134 167.463 2003.284

11 43.715 856.898 15709.788 801.446

12 15.544 345.993 6343.207 284.981

13 14.919 93.649 1716.894 273.522

14 7.237 194.680 3569.131 132.677

15 7.162 79.486 1457.244 131.304

16 6.635 123.179 2258.280 121.640

17 254.179 139.111 2550.373 4659.939

18 7.204 23.367 428.403 132.073

19 6.938 41.227 755.829 127.201

20 11.195 498.973 9147.837 205.251

21 10.997 162.317 2975.807 201.619

22 3.113 134.106 2458.602 57.063

23 3.136 311.702 5714.534 57.488

24 17.237 13.229 242.529 316.014

25 16.735 11.862 217.473 306.801

26 14.133 13.272 243.325 259.100

27 13.798 15.006 275.109 252.959

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -12.058 kip
Governing Restoring Force : 18.415 kip
Minimum Sliding Ratio for the Critical Load Case : 1.527
Critical Load Case for Overturning about X-Direction : 9
Governing Overturning Moment : 2.787 kip-ft
Governing Resisting Moment : 458.069 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 164.381

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 2.787 kip
Governing Restoring Force : 24.986 kip
Minimum Sliding Ratio for the Critical Load Case : 8.966
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 12.058 kip-ft
Governing Resisting Moment : 337.599 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 27.998

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 109 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 86.159 kip, Load Case # 15

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 222.624 kip

Distance along X to design for shear,


Dx = 10.654 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 166.968 kip

Critical load case for Vux is # 15 36.741 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 110 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 222.624 kip

Distance along X to design for shear, Dz = 10.654 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 166.968 kip

Critical load case for Vuz is # 15 37.440 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 15

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 111 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 8.346 ft
a distance, Dx =

Ultimate moment, 170.501 kip-ft

Nominal moment capacity, Mn = 189.446 kip-ft

Required = 0.00276

Since OK

Area of Steel Required, As = 4.854 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 4.855 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 4.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


8.096 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 45

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 4.950 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00255

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 4.855 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 112 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 15

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 8.346 ft
a distance, Dz =

Ultimate moment, 166.703 kip-ft

Nominal moment capacity, Mn = 185.226 kip-ft

Required = 0.00297

Since OK

Area of Steel Required, As = 4.989 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 8.896 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 8.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 113 of 352

Available development length for bars, DL


8.096 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 25

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 5.000 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00284

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 8.896 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 8.346 ft
at a distance, Dx =

Ultimate moment, 95.787 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 114 of 352

Nominal moment capacity, Mn = 106.430 kip-ft

Required = 0.00169

Since OK

Area of Steel Required, As = 3.019 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 8.346 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 115 of 352

Ultimate moment, 95.787 kip-ft

Nominal moment capacity, Mn = 106.430 kip-ft

Required = 0.00153

Since OK

Area of Steel Required, As = 3.168 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.629 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 38

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 116 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 117 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 118 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 37.055 0.144 0.098 0.000 0.000
2 0.214 0.018 0.111 0.000 0.000
3 3.179 0.005 -0.021 0.000 0.000
4 0.214 0.001 -0.022 0.000 0.000
5 3.200 -0.001 -0.021 0.000 0.000
6 0.477 -0.847 0.349 0.000 0.000
7 -2.884 8.004 -0.441 0.000 0.000
8 2.449 -0.525 0.144 0.000 0.000
9 0.784 0.076 2.718 0.000 0.000
10 -0.783 -0.099 -2.635 0.000 0.000
11 51.878 0.202 0.137 0.000 0.000
12 50.168 -0.222 0.436 0.000 0.000
13 50.134 -0.240 0.222 0.000 0.000
14 48.645 -1.164 0.766 0.000 0.000
15 48.623 -1.175 0.632 0.000 0.000
16 42.923 5.222 0.323 0.000 0.000
17 47.189 -1.601 0.791 0.000 0.000
18 45.857 -1.120 2.850 0.000 0.000
19 44.604 -1.261 -1.432 0.000 0.000
20 43.505 12.574 -0.324 0.000 0.000
21 43.484 12.562 -0.458 0.000 0.000
22 52.038 -1.072 0.612 0.000 0.000
23 52.017 -1.084 0.478 0.000 0.000
24 49.374 -0.110 4.731 0.000 0.000
25 49.353 -0.122 4.597 0.000 0.000
26 46.867 -0.391 -3.834 0.000 0.000
27 46.846 -0.403 -3.968 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 37.055 0.144 0.098 0.000 0.000
2 0.214 0.018 0.111 0.000 0.000
3 3.179 0.005 -0.021 0.000 0.000
4 0.214 0.001 -0.022 0.000 0.000
5 3.200 -0.001 -0.021 0.000 0.000
6 0.477 -0.847 0.349 0.000 0.000
7 -2.884 8.004 -0.441 0.000 0.000
8 2.449 -0.525 0.144 0.000 0.000
9 0.784 0.076 2.718 0.000 0.000
10 -0.783 -0.099 -2.635 0.000 0.000
11 51.878 0.202 0.137 0.000 0.000
12 50.168 -0.222 0.436 0.000 0.000
13 50.134 -0.240 0.222 0.000 0.000
14 48.645 -1.164 0.766 0.000 0.000
15 48.623 -1.175 0.632 0.000 0.000
16 42.923 5.222 0.323 0.000 0.000
17 47.189 -1.601 0.791 0.000 0.000
18 45.857 -1.120 2.850 0.000 0.000
19 44.604 -1.261 -1.432 0.000 0.000
20 43.505 12.574 -0.324 0.000 0.000
21 43.484 12.562 -0.458 0.000 0.000
22 52.038 -1.072 0.612 0.000 0.000
23 52.017 -1.084 0.478 0.000 0.000
24 49.374 -0.110 4.731 0.000 0.000
25 49.353 -0.122 4.597 0.000 0.000
26 46.867 -0.391 -3.834 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 119 of 352

27 46.846 -0.403 -3.968 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 13.427 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 13.500 ft Governing Load Case : #7

Width (W2) = 13.500 ft Governing Load Case : #7

Depth (D2) = 1.000 ft Governing Load Case : #7

Area (A2) = 182.250 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

23 0.4369 0.4316 0.4339 0.4392 0.000

11 0.4338 0.4348 0.4355 0.4345 0.000

11 0.4338 0.4348 0.4355 0.4345 0.000

22 0.4367 0.4314 0.4344 0.4396 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

23 0.4369 0.4316 0.4339 0.4392

11 0.4338 0.4348 0.4355 0.4345

11 0.4338 0.4348 0.4355 0.4345

22 0.4367 0.4314 0.4344 0.4396

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 120 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 222.851 329.880 4453.381 3008.491

2 749.706 124.021 1674.289 10121.031

3 3028.119 713.386 9630.713 40879.612

4 12480.128 613.676 8284.631 168481.729

5 21251.289 732.061 9882.819 286892.402

6 16.428 39.835 537.771 221.773

7 1.528 27.727 374.316 20.623

8 28.375 103.370 1395.490 383.059

9 184.552 5.173 69.831 2491.452

10 133.660 5.039 68.033 1804.413

11 195.820 289.867 3913.201 2643.569

12 174.821 88.876 1199.824 2360.088

13 161.337 174.844 2360.388 2178.044

14 32.652 49.601 669.607 440.805

15 32.323 60.106 811.437 436.363

16 6.728 108.778 1468.509 90.823

17 23.274 47.110 635.989 314.201

18 32.670 12.840 173.335 441.046

19 28.534 25.119 339.107 385.207

20 2.817 109.447 1477.532 38.031

21 2.819 77.367 1044.459 38.054

22 37.020 64.804 874.855 499.767

23 36.617 82.942 1119.718 494.324

24 347.539 8.107 109.445 4691.775

25 314.620 8.341 112.605 4247.369

26 94.841 9.678 130.657 1280.358

27 92.103 9.349 126.206 1243.396

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 8.004 kip
Governing Restoring Force : 12.227 kip
Minimum Sliding Ratio for the Critical Load Case : 1.528

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 121 of 352

Critical Load Case for Overturning about X-Direction : 10


Governing Overturning Moment : -2.635 kip-ft
Governing Resisting Moment : 179.243 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 68.033

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -2.635 kip
Governing Restoring Force : 13.277 kip
Minimum Sliding Ratio for the Critical Load Case : 5.039
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -8.004 kip-ft
Governing Resisting Moment : 165.059 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 20.623

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 50.518 kip, Load Case # 22

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 122 of 352

From ACI Cl.11.3.1.1, Vc = 163.932 kip

Distance along X to design for shear,


Dx = 8.237 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 122.949 kip

Critical load case for Vux is # 22 20.352 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 163.932 kip

Distance along X to design for shear, Dz = 5.263 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 122.949 kip

Critical load case for Vuz is # 22 20.401 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 123 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 22

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.930 ft
a distance, Dx =

Ultimate moment, 68.208 kip-ft

Nominal moment capacity, Mn = 75.787 kip-ft

Required = 0.00148

Since OK

Area of Steel Required, As = 2.333 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 14.136 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 124 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.680 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 12

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.400 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.729 ft
=

Reinforcement ratio, = 0.00169

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 14.136 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 22

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.930 ft
a distance, Dz =

Ultimate moment, 68.020 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 125 of 352

Nominal moment capacity, Mn = 75.578 kip-ft

Required = 0.00168

Since OK

Area of Steel Required, As = 2.187 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.550 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.680 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.655 ft
=

Reinforcement ratio, = 0.00173

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 15.550 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 126 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.930 ft
at a distance, Dx =

Ultimate moment, 35.602 kip-ft

Nominal moment capacity, Mn = 39.558 kip-ft

Required = 0.00101

Since OK

Area of Steel Required, As = 2.041 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 8.646 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 8 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 127 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.930 ft
at a distance, Dx =

Ultimate moment, 35.602 kip-ft

Nominal moment capacity, Mn = 39.558 kip-ft

Required = 0.00077

Since OK

Area of Steel Required, As = 2.333 in2

Selected bar Size = #8


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#8 @ 18 in o.c.

Isolated Footing 39

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 128 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 129 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 130 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 37.053 -0.143 0.092 0.000 0.000
2 0.778 -0.007 0.230 0.000 0.000
3 2.615 -0.016 -0.143 0.000 0.000
4 0.774 -0.004 -0.073 0.000 0.000
5 2.640 0.004 0.027 0.000 0.000
6 0.477 0.847 0.349 0.000 0.000
7 2.449 0.525 0.144 0.000 0.000
8 -2.884 -8.004 -0.441 0.000 0.000
9 0.784 -0.076 2.718 0.000 0.000
10 -0.783 0.099 -2.635 0.000 0.000
11 51.874 -0.200 0.128 0.000 0.000
12 50.170 0.247 0.696 0.000 0.000
13 50.124 0.219 -0.061 0.000 0.000
14 48.645 1.180 0.926 0.000 0.000
15 48.616 1.163 0.453 0.000 0.000
16 47.186 1.603 0.784 0.000 0.000
17 42.920 -5.220 0.316 0.000 0.000
18 45.854 1.122 2.843 0.000 0.000
19 44.601 1.262 -1.439 0.000 0.000
20 52.038 1.088 0.772 0.000 0.000
21 52.009 1.071 0.299 0.000 0.000
22 43.505 -12.557 -0.164 0.000 0.000
23 43.476 -12.574 -0.637 0.000 0.000
24 49.374 0.127 4.891 0.000 0.000
25 49.345 0.110 4.418 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 131 of 352

26 46.867 0.408 -3.674 0.000 0.000


27 46.838 0.390 -4.147 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 37.053 -0.143 0.092 0.000 0.000
2 0.778 -0.007 0.230 0.000 0.000
3 2.615 -0.016 -0.143 0.000 0.000
4 0.774 -0.004 -0.073 0.000 0.000
5 2.640 0.004 0.027 0.000 0.000
6 0.477 0.847 0.349 0.000 0.000
7 2.449 0.525 0.144 0.000 0.000
8 -2.884 -8.004 -0.441 0.000 0.000
9 0.784 -0.076 2.718 0.000 0.000
10 -0.783 0.099 -2.635 0.000 0.000
11 51.874 -0.200 0.128 0.000 0.000
12 50.170 0.247 0.696 0.000 0.000
13 50.124 0.219 -0.061 0.000 0.000
14 48.645 1.180 0.926 0.000 0.000
15 48.616 1.163 0.453 0.000 0.000
16 47.186 1.603 0.784 0.000 0.000
17 42.920 -5.220 0.316 0.000 0.000
18 45.854 1.122 2.843 0.000 0.000
19 44.601 1.262 -1.439 0.000 0.000
20 52.038 1.088 0.772 0.000 0.000
21 52.009 1.071 0.299 0.000 0.000
22 43.505 -12.557 -0.164 0.000 0.000
23 43.476 -12.574 -0.637 0.000 0.000
24 49.374 0.127 4.891 0.000 0.000
25 49.345 0.110 4.418 0.000 0.000
26 46.867 0.408 -3.674 0.000 0.000
27 46.838 0.390 -4.147 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 13.427 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 13.500 ft Governing Load Case : #8

Width (W2) = 13.500 ft Governing Load Case : #8

Depth (D2) = 1.000 ft Governing Load Case : #8

Area (A2) = 182.250 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 132 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

11 0.4348 0.4338 0.4345 0.4354 0.000

21 0.4320 0.4373 0.4387 0.4335 0.000

20 0.4310 0.4363 0.4401 0.4348 0.000

11 0.4348 0.4338 0.4345 0.4354 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

11 0.4348 0.4338 0.4345 0.4354

21 0.4320 0.4373 0.4387 0.4335

20 0.4310 0.4363 0.4401 0.4348

11 0.4348 0.4338 0.4345 0.4354

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 224.880 351.325 4742.887 3035.879

2 2029.454 61.044 824.091 27397.631

3 955.767 104.993 1417.411 12902.855

4 3187.497 192.019 2592.257 43031.204

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 133 of 352

5 3732.863 559.734 7556.403 50393.647

6 16.428 39.835 537.771 221.773

7 28.375 103.370 1395.490 383.059

8 1.528 27.727 374.316 20.623

9 184.552 5.173 69.831 2491.452

10 133.660 5.039 68.033 1804.413

11 197.601 308.708 4167.558 2667.619

12 157.003 55.694 751.867 2119.536

13 176.558 636.882 8597.911 2383.528

14 32.201 41.043 554.083 434.707

15 32.664 83.884 1132.434 440.960

16 23.250 47.538 641.764 313.879

17 6.729 111.237 1501.704 90.846

18 32.623 12.871 173.763 440.408

19 28.497 24.993 337.406 384.710

20 36.465 51.401 693.912 492.274

21 37.036 132.592 1789.992 499.984

22 2.821 216.056 2916.750 38.080

23 2.816 55.597 750.556 38.013

24 302.775 7.842 105.871 4087.460

25 350.108 8.679 117.160 4726.460

26 91.044 10.099 136.336 1229.092

27 95.011 8.944 120.741 1282.653

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -8.004 kip
Governing Restoring Force : 12.227 kip
Minimum Sliding Ratio for the Critical Load Case : 1.528
Critical Load Case for Overturning about X-Direction : 10
Governing Overturning Moment : -2.635 kip-ft
Governing Resisting Moment : 179.243 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 68.033

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -2.635 kip
Governing Restoring Force : 13.277 kip
Minimum Sliding Ratio for the Critical Load Case : 5.039
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 8.004 kip-ft
Governing Resisting Moment : 165.059 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 20.623

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 134 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 50.518 kip, Load Case # 20

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 163.932 kip

Distance along X to design for shear,


Dx = 8.237 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 122.949 kip

Critical load case for Vux is # 20 20.369 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 135 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 163.932 kip

Distance along X to design for shear, Dz = 8.237 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 122.949 kip

Critical load case for Vuz is # 20 20.403 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 20

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 136 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.930 ft
a distance, Dx =

Ultimate moment, 68.215 kip-ft

Nominal moment capacity, Mn = 75.795 kip-ft

Required = 0.00148

Since OK

Area of Steel Required, As = 2.333 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 14.136 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.680 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 12

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.400 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.729 ft
=

Reinforcement ratio, = 0.00169

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 14.136 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 137 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 20

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.930 ft
a distance, Dz =

Ultimate moment, 68.086 kip-ft

Nominal moment capacity, Mn = 75.651 kip-ft

Required = 0.00169

Since OK

Area of Steel Required, As = 2.187 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.550 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 138 of 352

Available development length for bars, DL


5.680 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.655 ft
=

Reinforcement ratio, = 0.00173

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 15.550 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.930 ft
at a distance, Dx =

Ultimate moment, 35.602 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 139 of 352

Nominal moment capacity, Mn = 39.558 kip-ft

Required = 0.00101

Since OK

Area of Steel Required, As = 2.041 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 8.646 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 8 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.930 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 140 of 352

Ultimate moment, 35.602 kip-ft

Nominal moment capacity, Mn = 39.558 kip-ft

Required = 0.00077

Since OK

Area of Steel Required, As = 2.333 in2

Selected bar Size = #8


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#8 @ 18 in o.c.

Isolated Footing 40

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 141 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 142 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 143 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 37.675 -0.932 -0.919 0.000 0.000
2 1.919 -0.078 -0.071 0.000 0.000
3 1.601 -0.178 -0.204 0.000 0.000
4 1.945 0.020 0.042 0.000 0.000
5 1.513 0.056 0.049 0.000 0.000
6 0.331 -0.005 0.237 0.000 0.000
7 -6.442 4.264 0.125 0.000 0.000
8 6.156 -2.164 -0.281 0.000 0.000
9 -6.656 0.299 4.267 0.000 0.000
10 6.426 -0.270 -2.164 0.000 0.000
11 52.746 -1.305 -1.286 0.000 0.000
12 50.866 -1.155 -1.018 0.000 0.000
13 51.050 -1.374 -1.243 0.000 0.000
14 49.171 -1.148 -0.745 0.000 0.000
15 49.286 -1.284 -0.886 0.000 0.000
16 40.586 2.284 -0.624 0.000 0.000
17 50.664 -2.858 -0.949 0.000 0.000
18 40.415 -0.887 2.690 0.000 0.000
19 50.881 -1.343 -2.455 0.000 0.000
20 38.500 5.679 -0.805 0.000 0.000
21 38.615 5.543 -0.946 0.000 0.000
22 58.657 -4.606 -1.456 0.000 0.000
23 58.771 -4.742 -1.596 0.000 0.000
24 38.159 -0.665 5.822 0.000 0.000
25 38.274 -0.801 5.681 0.000 0.000
26 59.089 -1.575 -4.467 0.000 0.000
27 59.204 -1.711 -4.607 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 37.675 -0.932 -0.919 0.000 0.000
2 1.919 -0.078 -0.071 0.000 0.000
3 1.601 -0.178 -0.204 0.000 0.000
4 1.945 0.020 0.042 0.000 0.000
5 1.513 0.056 0.049 0.000 0.000
6 0.331 -0.005 0.237 0.000 0.000
7 -6.442 4.264 0.125 0.000 0.000
8 6.156 -2.164 -0.281 0.000 0.000
9 -6.656 0.299 4.267 0.000 0.000
10 6.426 -0.270 -2.164 0.000 0.000
11 52.746 -1.305 -1.286 0.000 0.000
12 50.866 -1.155 -1.018 0.000 0.000
13 51.050 -1.374 -1.243 0.000 0.000
14 49.171 -1.148 -0.745 0.000 0.000
15 49.286 -1.284 -0.886 0.000 0.000
16 40.586 2.284 -0.624 0.000 0.000
17 50.664 -2.858 -0.949 0.000 0.000
18 40.415 -0.887 2.690 0.000 0.000
19 50.881 -1.343 -2.455 0.000 0.000
20 38.500 5.679 -0.805 0.000 0.000
21 38.615 5.543 -0.946 0.000 0.000
22 58.657 -4.606 -1.456 0.000 0.000
23 58.771 -4.742 -1.596 0.000 0.000
24 38.159 -0.665 5.822 0.000 0.000
25 38.274 -0.801 5.681 0.000 0.000
26 59.089 -1.575 -4.467 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 144 of 352

27 59.204 -1.711 -4.607 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 15.219 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 11.500 ft Governing Load Case : #9

Width (W2) = 11.500 ft Governing Load Case : #9

Depth (D2) = 1.000 ft Governing Load Case : #9

Area (A2) = 132.250 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

27 0.6226 0.6091 0.5727 0.5862 0.000

27 0.6226 0.6091 0.5727 0.5862 0.000

26 0.6206 0.6082 0.5730 0.5854 0.000

23 0.6194 0.5820 0.5694 0.6068 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

27 0.6226 0.6091 0.5727 0.5862

27 0.6226 0.6091 0.5727 0.5862

26 0.6206 0.6082 0.5730 0.5854

23 0.6194 0.5820 0.5694 0.6068

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 145 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 30.843 31.302 359.973 354.700

2 139.994 153.720 1767.781 1609.934

3 60.188 52.638 605.340 692.158

4 534.215 258.954 2977.971 6143.478

5 189.693 215.683 2480.353 2181.465

6 2113.485 42.634 490.287 24305.080

7 1.571 53.541 615.718 18.066

8 6.005 46.185 531.124 69.057

9 22.059 1.545 17.764 253.682

10 48.569 6.069 69.798 558.542

11 27.804 28.217 324.497 319.744

12 30.595 34.721 399.287 351.845

13 25.805 28.522 328.003 296.757

14 30.060 46.300 532.449 345.686

15 26.914 39.029 448.830 309.514

16 13.225 48.425 556.887 152.091

17 12.335 37.142 427.131 141.849

18 33.949 11.201 128.817 390.411

19 26.334 14.404 165.644 302.836

20 5.136 36.223 416.559 59.066

21 5.273 30.908 355.445 60.638

22 8.522 26.962 310.057 98.000

23 8.289 24.627 283.212 95.323

24 43.635 4.981 57.283 501.800

25 36.281 5.114 58.815 417.231

26 25.053 8.834 101.592 288.105

27 23.091 8.577 98.641 265.550

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 4.264 kip
Governing Restoring Force : 6.698 kip
Minimum Sliding Ratio for the Critical Load Case : 1.571

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 146 of 352

Critical Load Case for Overturning about X-Direction : 9


Governing Overturning Moment : 4.267 kip-ft
Governing Resisting Moment : 75.796 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 17.764

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 4.267 kip
Governing Restoring Force : 6.591 kip
Minimum Sliding Ratio for the Critical Load Case : 1.545
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -4.264 kip-ft
Governing Resisting Moment : 77.024 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 18.066

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 56.821 kip, Load Case # 27

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 147 of 352

From ACI Cl.11.3.1.1, Vc = 139.646 kip

Distance along X to design for shear,


Dx = 4.263 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 104.735 kip

Critical load case for Vux is # 27 22.508 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 139.646 kip

Distance along X to design for shear, Dz = 4.263 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 104.735 kip

Critical load case for Vuz is # 23 22.364 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 148 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 23

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 4.930 ft
a distance, Dx =

Ultimate moment, 63.967 kip-ft

Nominal moment capacity, Mn = 71.074 kip-ft

Required = 0.00163

Since OK

Area of Steel Required, As = 1.987 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 14.611 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 149 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


4.680 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 10

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.000 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.729 ft
=

Reinforcement ratio, = 0.00166

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 14.611 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 27

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 4.930 ft
a distance, Dz =

Ultimate moment, 64.371 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 150 of 352

Nominal moment capacity, Mn = 71.523 kip-ft

Required = 0.00187

Since OK

Area of Steel Required, As = 1.939 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.743 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


4.680 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 18

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.980 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.655 ft
=

Reinforcement ratio, = 0.00182

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 7.743 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 151 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 4.930 ft
at a distance, Dx =

Ultimate moment, 20.961 kip-ft

Nominal moment capacity, Mn = 23.290 kip-ft

Required = 0.00072

Since OK

Area of Steel Required, As = 1.707 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 152 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 4.930 ft
at a distance, Dx =

Ultimate moment, 20.961 kip-ft

Nominal moment capacity, Mn = 23.290 kip-ft

Required = 0.00053

Since OK

Area of Steel Required, As = 1.987 in2

Selected bar Size = #9


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#9 @ 18 in o.c.

Isolated Footing 41

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 153 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 154 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 155 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 37.455 0.920 -0.924 0.000 0.000
2 1.750 0.047 -0.200 0.000 0.000
3 1.716 0.197 -0.077 0.000 0.000
4 1.747 -0.014 0.088 0.000 0.000
5 1.683 -0.060 0.001 0.000 0.000
6 0.331 0.005 0.237 0.000 0.000
7 6.156 2.164 -0.281 0.000 0.000
8 -6.442 -4.264 0.125 0.000 0.000
9 -6.656 -0.299 4.267 0.000 0.000
10 6.426 0.270 -2.164 0.000 0.000
11 52.436 1.287 -1.294 0.000 0.000
12 50.603 1.084 -1.309 0.000 0.000
13 50.651 1.398 -0.972 0.000 0.000
14 48.907 1.098 -0.929 0.000 0.000
15 48.938 1.294 -0.719 0.000 0.000
16 50.399 2.843 -0.956 0.000 0.000
17 40.321 -2.300 -0.630 0.000 0.000
18 40.150 0.872 2.683 0.000 0.000
19 50.615 1.327 -2.461 0.000 0.000
20 58.392 4.555 -1.640 0.000 0.000
21 58.423 4.751 -1.430 0.000 0.000
22 38.236 -5.729 -0.989 0.000 0.000
23 38.266 -5.533 -0.779 0.000 0.000
24 37.894 0.614 5.637 0.000 0.000
25 37.925 0.811 5.848 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 156 of 352

26 58.825 1.525 -4.651 0.000 0.000


27 58.855 1.721 -4.441 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 37.455 0.920 -0.924 0.000 0.000
2 1.750 0.047 -0.200 0.000 0.000
3 1.716 0.197 -0.077 0.000 0.000
4 1.747 -0.014 0.088 0.000 0.000
5 1.683 -0.060 0.001 0.000 0.000
6 0.331 0.005 0.237 0.000 0.000
7 6.156 2.164 -0.281 0.000 0.000
8 -6.442 -4.264 0.125 0.000 0.000
9 -6.656 -0.299 4.267 0.000 0.000
10 6.426 0.270 -2.164 0.000 0.000
11 52.436 1.287 -1.294 0.000 0.000
12 50.603 1.084 -1.309 0.000 0.000
13 50.651 1.398 -0.972 0.000 0.000
14 48.907 1.098 -0.929 0.000 0.000
15 48.938 1.294 -0.719 0.000 0.000
16 50.399 2.843 -0.956 0.000 0.000
17 40.321 -2.300 -0.630 0.000 0.000
18 40.150 0.872 2.683 0.000 0.000
19 50.615 1.327 -2.461 0.000 0.000
20 58.392 4.555 -1.640 0.000 0.000
21 58.423 4.751 -1.430 0.000 0.000
22 38.236 -5.729 -0.989 0.000 0.000
23 38.266 -5.533 -0.779 0.000 0.000
24 37.894 0.614 5.637 0.000 0.000
25 37.925 0.811 5.848 0.000 0.000
26 58.825 1.525 -4.651 0.000 0.000
27 58.855 1.721 -4.441 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 15.131 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 11.500 ft Governing Load Case : #9

Width (W2) = 11.500 ft Governing Load Case : #9

Depth (D2) = 1.000 ft Governing Load Case : #9

Area (A2) = 132.250 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 157 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

26 0.6071 0.6192 0.5825 0.5704 0.000

27 0.6058 0.6193 0.5843 0.5707 0.000

21 0.5787 0.6161 0.6049 0.5674 0.000

27 0.6058 0.6193 0.5843 0.5707 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

26 0.6071 0.6192 0.5825 0.5704

27 0.6058 0.6193 0.5843 0.5707

21 0.5787 0.6161 0.6049 0.5674

27 0.6058 0.6193 0.5843 0.5707

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 31.153 30.998 356.477 358.256

2 231.726 53.960 620.540 2664.845

3 54.733 140.863 1619.920 629.428

4 762.508 122.774 1411.901 8768.843

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 158 of 352

5 178.995 9283.048 106755.048 2058.448

6 2113.485 42.634 490.287 24305.080

7 6.005 46.185 531.124 69.057

8 1.571 53.541 615.720 18.066

9 22.059 1.545 17.764 253.682

10 48.569 6.069 69.798 558.542

11 28.071 27.931 321.211 322.814

12 32.486 26.909 309.450 373.587

13 25.207 36.243 416.796 289.878

14 31.318 36.985 425.323 360.153

15 26.578 47.820 549.932 305.651

16 12.355 36.749 422.616 142.079

17 13.079 47.713 548.699 150.412

18 34.395 11.179 128.562 395.540

19 26.539 14.312 164.585 305.193

20 8.587 23.853 274.315 98.750

21 8.235 27.373 314.786 94.707

22 5.068 29.348 337.500 58.282

23 5.251 37.288 428.807 60.382

24 46.995 5.120 58.885 540.441

25 35.633 4.939 56.798 409.780

26 25.793 8.456 97.243 296.617

27 22.860 8.860 101.887 262.893

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -4.264 kip
Governing Restoring Force : 6.698 kip
Minimum Sliding Ratio for the Critical Load Case : 1.571
Critical Load Case for Overturning about X-Direction : 9
Governing Overturning Moment : 4.267 kip-ft
Governing Resisting Moment : 75.796 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 17.764

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 4.267 kip
Governing Restoring Force : 6.591 kip
Minimum Sliding Ratio for the Critical Load Case : 1.545
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 4.264 kip-ft
Governing Resisting Moment : 77.024 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 18.066

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 159 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 56.486 kip, Load Case # 27

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 139.646 kip

Distance along X to design for shear,


Dx = 4.263 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 104.735 kip

Critical load case for Vux is # 26 22.373 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 160 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 139.646 kip

Distance along X to design for shear, Dz = 7.237 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 104.735 kip

Critical load case for Vuz is # 21 22.236 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 21

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 161 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 4.930 ft
a distance, Dx =

Ultimate moment, 63.604 kip-ft

Nominal moment capacity, Mn = 70.672 kip-ft

Required = 0.00162

Since OK

Area of Steel Required, As = 1.987 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 14.611 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


4.680 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 10

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.000 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.729 ft
=

Reinforcement ratio, = 0.00166

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 14.611 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 162 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 26

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 4.930 ft
a distance, Dz =

Ultimate moment, 63.988 kip-ft

Nominal moment capacity, Mn = 71.097 kip-ft

Required = 0.00186

Since OK

Area of Steel Required, As = 1.928 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.743 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 163 of 352

Available development length for bars, DL


4.680 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 18

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.980 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.655 ft
=

Reinforcement ratio, = 0.00182

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 7.743 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 4.930 ft
at a distance, Dx =

Ultimate moment, 20.961 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 164 of 352

Nominal moment capacity, Mn = 23.290 kip-ft

Required = 0.00072

Since OK

Area of Steel Required, As = 1.707 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 4.930 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 165 of 352

Ultimate moment, 20.961 kip-ft

Nominal moment capacity, Mn = 23.290 kip-ft

Required = 0.00053

Since OK

Area of Steel Required, As = 1.987 in2

Selected bar Size = #9


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#9 @ 18 in o.c.

Isolated Footing 42

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 166 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 167 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 168 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 36.651 0.030 0.107 0.000 0.000
2 0.139 0.066 0.025 0.000 0.000
3 2.916 0.016 -0.007 0.000 0.000
4 0.146 -0.040 -0.016 0.000 0.000
5 2.903 -0.004 -0.000 0.000 0.000
6 0.191 0.005 -0.160 0.000 0.000
7 0.732 2.705 0.100 0.000 0.000
8 -0.781 -2.635 -0.029 0.000 0.000
9 -2.922 -0.252 7.818 0.000 0.000
10 2.698 0.219 -0.894 0.000 0.000
11 51.311 0.041 0.150 0.000 0.000
12 48.944 0.138 0.089 0.000 0.000
13 48.977 -0.001 0.011 0.000 0.000
14 47.329 0.106 -0.102 0.000 0.000
15 47.350 0.019 -0.150 0.000 0.000
16 44.872 2.208 -0.047 0.000 0.000
17 43.662 -2.064 -0.150 0.000 0.000
18 41.950 -0.158 6.128 0.000 0.000
19 46.446 0.219 -0.842 0.000 0.000
20 48.289 4.429 0.233 0.000 0.000
21 48.310 4.342 0.185 0.000 0.000
22 45.869 -4.116 0.027 0.000 0.000
23 45.890 -4.203 -0.021 0.000 0.000
24 42.444 -0.302 12.583 0.000 0.000
25 42.465 -0.389 12.534 0.000 0.000
26 51.436 0.451 -1.357 0.000 0.000
27 51.457 0.364 -1.405 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 36.651 0.030 0.107 0.000 0.000
2 0.139 0.066 0.025 0.000 0.000
3 2.916 0.016 -0.007 0.000 0.000
4 0.146 -0.040 -0.016 0.000 0.000
5 2.903 -0.004 -0.000 0.000 0.000
6 0.191 0.005 -0.160 0.000 0.000
7 0.732 2.705 0.100 0.000 0.000
8 -0.781 -2.635 -0.029 0.000 0.000
9 -2.922 -0.252 7.818 0.000 0.000
10 2.698 0.219 -0.894 0.000 0.000
11 51.311 0.041 0.150 0.000 0.000
12 48.944 0.138 0.089 0.000 0.000
13 48.977 -0.001 0.011 0.000 0.000
14 47.329 0.106 -0.102 0.000 0.000
15 47.350 0.019 -0.150 0.000 0.000
16 44.872 2.208 -0.047 0.000 0.000
17 43.662 -2.064 -0.150 0.000 0.000
18 41.950 -0.158 6.128 0.000 0.000
19 46.446 0.219 -0.842 0.000 0.000
20 48.289 4.429 0.233 0.000 0.000
21 48.310 4.342 0.185 0.000 0.000
22 45.869 -4.116 0.027 0.000 0.000
23 45.890 -4.203 -0.021 0.000 0.000
24 42.444 -0.302 12.583 0.000 0.000
25 42.465 -0.389 12.534 0.000 0.000
26 51.436 0.451 -1.357 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 169 of 352

27 51.457 0.364 -1.405 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 13.282 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 13.333 ft Governing Load Case : #9

Width (W2) = 13.333 ft Governing Load Case : #9

Depth (D2) = 1.000 ft Governing Load Case : #9

Area (A2) = 177.778 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

27 0.4421 0.4439 0.4368 0.4350 0.000

27 0.4421 0.4439 0.4368 0.4350 0.000

11 0.4381 0.4384 0.4391 0.4389 0.000

11 0.4381 0.4384 0.4391 0.4389 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

27 0.4421 0.4439 0.4368 0.4350

27 0.4421 0.4439 0.4368 0.4350

11 0.4381 0.4384 0.4391 0.4389

11 0.4381 0.4384 0.4391 0.4389

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 170 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 1068.697 295.915 3945.528 14249.300

2 202.067 527.688 7035.842 2694.230

3 946.417 2088.624 27848.316 12618.887

4 332.017 817.136 10895.145 4426.894

5 3628.260 38347.427 511299.030 48376.799

6 2578.550 84.191 1122.542 34380.664

7 5.064 137.369 1831.592 67.515

8 4.911 446.426 5952.349 65.486

9 47.162 1.519 20.248 628.823

10 66.949 16.421 218.945 892.660

11 940.102 260.307 3470.764 12534.689

12 274.431 426.443 5685.901 3659.082

13 26136.286 3423.115 45641.538 348483.810

14 348.592 363.393 4845.234 4647.899

15 1934.409 246.204 3282.725 25792.119

16 16.198 760.317 10137.566 215.978

17 17.034 234.400 3125.328 227.126

18 217.814 5.599 74.652 2904.189

19 166.675 43.409 578.786 2222.328

20 8.462 160.709 2142.785 112.824

21 8.634 202.966 2706.218 115.117

22 8.811 1330.606 17741.415 117.486

23 8.632 1707.569 22767.592 115.087

24 114.278 2.746 36.617 1523.713

25 88.771 2.758 36.769 1183.608

26 86.531 28.778 383.710 1153.750

27 107.226 27.792 370.566 1429.674

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -2.635 kip
Governing Restoring Force : 12.943 kip
Minimum Sliding Ratio for the Critical Load Case : 4.911

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 171 of 352

Critical Load Case for Overturning about X-Direction : 9


Governing Overturning Moment : 7.818 kip-ft
Governing Resisting Moment : 158.300 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 20.248

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 7.818 kip
Governing Restoring Force : 11.873 kip
Minimum Sliding Ratio for the Critical Load Case : 1.519
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 2.635 kip-ft
Governing Resisting Moment : 172.572 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 65.486

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 49.916 kip, Load Case # 27

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 172 of 352

From ACI Cl.11.3.1.1, Vc = 161.909 kip

Distance along X to design for shear,


Dx = 5.180 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 121.431 kip

Critical load case for Vux is # 27 20.140 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 161.909 kip

Distance along X to design for shear, Dz = 8.154 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 121.431 kip

Critical load case for Vuz is # 26 20.030 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 173 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 26

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.846 ft
a distance, Dx =

Ultimate moment, 66.114 kip-ft

Nominal moment capacity, Mn = 73.460 kip-ft

Required = 0.00145

Since OK

Area of Steel Required, As = 2.304 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 7.681 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 174 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.596 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 21

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.310 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00164

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 7.681 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 27

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.846 ft
a distance, Dz =

Ultimate moment, 66.530 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 175 of 352

Nominal moment capacity, Mn = 73.922 kip-ft

Required = 0.00161

Since OK

Area of Steel Required, As = 2.196 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.350 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.596 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00172

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 15.350 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 176 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.846 ft
at a distance, Dx =

Ultimate moment, 34.181 kip-ft

Nominal moment capacity, Mn = 37.979 kip-ft

Required = 0.00082

Since OK

Area of Steel Required, As = 2.196 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 177 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.846 ft
at a distance, Dx =

Ultimate moment, 34.181 kip-ft

Nominal moment capacity, Mn = 37.979 kip-ft

Required = 0.00075

Since OK

Area of Steel Required, As = 2.304 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.681 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 43

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 178 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 179 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 180 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 43.777 0.003 -1.138 0.000 0.000
2 3.698 -0.175 -0.257 0.000 0.000
3 1.669 0.175 -0.123 0.000 0.000
4 3.649 0.067 -0.101 0.000 0.000
5 1.624 -0.067 -0.090 0.000 0.000
6 0.778 0.000 -0.626 0.000 0.000
7 -0.294 2.779 0.156 0.000 0.000
8 -0.294 -2.779 0.156 0.000 0.000
9 -12.292 0.000 11.233 0.000 0.000
10 10.895 0.000 -3.766 0.000 0.000
11 61.288 0.004 -1.594 0.000 0.000
12 61.438 -0.382 -2.234 0.000 0.000
13 61.430 0.391 -2.037 0.000 0.000
14 59.100 -0.238 -2.714 0.000 0.000
15 59.095 0.246 -2.591 0.000 0.000
16 53.542 2.227 -2.243 0.000 0.000
17 53.542 -2.220 -2.243 0.000 0.000
18 43.944 0.004 6.619 0.000 0.000
19 62.493 0.004 -5.380 0.000 0.000
20 57.774 4.209 -1.776 0.000 0.000
21 57.769 4.693 -1.653 0.000 0.000
22 57.774 -4.684 -1.776 0.000 0.000
23 57.769 -4.201 -1.653 0.000 0.000
24 38.578 -0.238 15.946 0.000 0.000
25 38.573 0.246 16.070 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 181 of 352

26 75.676 -0.238 -8.052 0.000 0.000


27 75.671 0.246 -7.929 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 43.777 0.003 -1.138 0.000 0.000
2 3.698 -0.175 -0.257 0.000 0.000
3 1.669 0.175 -0.123 0.000 0.000
4 3.649 0.067 -0.101 0.000 0.000
5 1.624 -0.067 -0.090 0.000 0.000
6 0.778 0.000 -0.626 0.000 0.000
7 -0.294 2.779 0.156 0.000 0.000
8 -0.294 -2.779 0.156 0.000 0.000
9 -12.292 0.000 11.233 0.000 0.000
10 10.895 0.000 -3.766 0.000 0.000
11 61.288 0.004 -1.594 0.000 0.000
12 61.438 -0.382 -2.234 0.000 0.000
13 61.430 0.391 -2.037 0.000 0.000
14 59.100 -0.238 -2.714 0.000 0.000
15 59.095 0.246 -2.591 0.000 0.000
16 53.542 2.227 -2.243 0.000 0.000
17 53.542 -2.220 -2.243 0.000 0.000
18 43.944 0.004 6.619 0.000 0.000
19 62.493 0.004 -5.380 0.000 0.000
20 57.774 4.209 -1.776 0.000 0.000
21 57.769 4.693 -1.653 0.000 0.000
22 57.774 -4.684 -1.776 0.000 0.000
23 57.769 -4.201 -1.653 0.000 0.000
24 38.578 -0.238 15.946 0.000 0.000
25 38.573 0.246 16.070 0.000 0.000
26 75.676 -0.238 -8.052 0.000 0.000
27 75.671 0.246 -7.929 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 19.337 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 17.667 ft Governing Load Case : #9

Width (W2) = 17.667 ft Governing Load Case : #9

Depth (D2) = 1.000 ft Governing Load Case : #9

Area (A2) = 312.111 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 182 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

26 0.4015 0.4010 0.3834 0.3840 0.000

27 0.4008 0.4013 0.3841 0.3836 0.000

27 0.4008 0.4013 0.3841 0.3836 0.000

26 0.4015 0.4010 0.3834 0.3840 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

26 0.4015 0.4010 0.3834 0.3840

27 0.4008 0.4013 0.3841 0.3836

27 0.4008 0.4013 0.3841 0.3836

26 0.4015 0.4010 0.3834 0.3840

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 14208.479 39.787 702.900 251016.460

2 144.660 98.450 1739.277 2555.667

3 138.383 197.014 3480.573 2444.769

4 377.892 250.762 4430.131 6676.086

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 183 of 352

5 362.516 267.998 4734.628 6404.457

6 N/A 38.028 671.827 N/A

7 8.370 149.012 2632.549 147.862

8 8.370 149.012 2632.549 147.862

9 N/A 1.537 27.150 N/A

10 N/A 7.662 135.360 N/A

11 12110.838 33.912 599.117 213958.134

12 141.534 24.227 428.011 2500.440

13 138.437 26.571 469.415 2445.729

14 222.902 19.510 344.683 3937.937

15 215.457 20.437 361.062 3806.407

16 22.530 22.376 395.307 398.025

17 22.607 22.376 395.307 399.397

18 11862.340 6.856 121.128 209568.006

19 14286.706 10.158 179.462 252398.465

20 12.424 29.441 520.132 219.488

21 11.144 31.635 558.889 196.870

22 11.164 29.441 520.132 197.224

23 12.448 31.635 558.889 219.906

24 179.713 2.678 47.303 3174.926

25 173.708 2.657 46.938 3068.848

26 257.787 7.606 134.381 4554.234

27 249.178 7.724 136.465 4402.137

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 2.779 kip
Governing Restoring Force : 23.261 kip
Minimum Sliding Ratio for the Critical Load Case : 8.370
Critical Load Case for Overturning about X-Direction : 9
Governing Overturning Moment : 11.233 kip-ft
Governing Resisting Moment : 304.971 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 27.150

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 11.233 kip
Governing Restoring Force : 17.263 kip
Minimum Sliding Ratio for the Critical Load Case : 1.537
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -2.779 kip-ft
Governing Resisting Moment : 410.949 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 147.862

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 184 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 74.385 kip, Load Case # 26

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 214.529 kip

Distance along X to design for shear,


Dx = 7.346 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 160.897 kip

Critical load case for Vux is # 26 32.133 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 185 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 214.529 kip

Distance along X to design for shear, Dz = 7.346 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 160.897 kip

Critical load case for Vuz is # 26 31.488 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 26

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 186 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 8.013 ft
a distance, Dx =

Ultimate moment, 137.626 kip-ft

Nominal moment capacity, Mn = 152.918 kip-ft

Required = 0.00230

Since OK

Area of Steel Required, As = 3.902 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 5.875 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 5.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


7.763 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 36

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 3.960 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00212

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 5.875 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 187 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 26

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 8.013 ft
a distance, Dz =

Ultimate moment, 140.989 kip-ft

Nominal moment capacity, Mn = 156.655 kip-ft

Required = 0.00260

Since OK

Area of Steel Required, As = 4.206 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 5.411 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 5.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 188 of 352

Available development length for bars, DL


7.763 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 39

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 4.290 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00253

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 5.411 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 8.013 ft
at a distance, Dx =

Ultimate moment, 85.078 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 189 of 352

Nominal moment capacity, Mn = 94.531 kip-ft

Required = 0.00172

Since OK

Area of Steel Required, As = 2.767 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 8.013 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 190 of 352

Ultimate moment, 85.078 kip-ft

Nominal moment capacity, Mn = 94.531 kip-ft

Required = 0.00141

Since OK

Area of Steel Required, As = 3.053 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Isolated Footing 44

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 191 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 192 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 193 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 36.400 -0.008 0.108 0.000 0.000
2 2.294 0.112 0.024 0.000 0.000
3 0.699 -0.179 -0.007 0.000 0.000
4 2.318 -0.041 -0.015 0.000 0.000
5 0.695 0.082 -0.001 0.000 0.000
6 0.191 -0.005 -0.160 0.000 0.000
7 -0.781 2.635 -0.029 0.000 0.000
8 0.732 -2.705 0.100 0.000 0.000
9 -2.922 0.252 7.818 0.000 0.000
10 2.698 -0.219 -0.894 0.000 0.000
11 50.960 -0.012 0.151 0.000 0.000
12 48.558 0.296 0.086 0.000 0.000
13 48.603 -0.364 0.015 0.000 0.000
14 46.974 0.175 -0.103 0.000 0.000
15 47.003 -0.238 -0.148 0.000 0.000
16 43.361 2.090 -0.149 0.000 0.000
17 44.571 -2.183 -0.046 0.000 0.000
18 41.648 0.183 6.128 0.000 0.000
19 46.144 -0.194 -0.841 0.000 0.000
20 45.515 4.397 0.026 0.000 0.000
21 45.543 3.984 -0.019 0.000 0.000
22 47.935 -4.148 0.232 0.000 0.000
23 47.963 -4.561 0.187 0.000 0.000
24 42.090 0.583 12.581 0.000 0.000
25 42.118 0.170 12.537 0.000 0.000
26 51.081 -0.170 -1.358 0.000 0.000
27 51.110 -0.583 -1.403 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 36.400 -0.008 0.108 0.000 0.000
2 2.294 0.112 0.024 0.000 0.000
3 0.699 -0.179 -0.007 0.000 0.000
4 2.318 -0.041 -0.015 0.000 0.000
5 0.695 0.082 -0.001 0.000 0.000
6 0.191 -0.005 -0.160 0.000 0.000
7 -0.781 2.635 -0.029 0.000 0.000
8 0.732 -2.705 0.100 0.000 0.000
9 -2.922 0.252 7.818 0.000 0.000
10 2.698 -0.219 -0.894 0.000 0.000
11 50.960 -0.012 0.151 0.000 0.000
12 48.558 0.296 0.086 0.000 0.000
13 48.603 -0.364 0.015 0.000 0.000
14 46.974 0.175 -0.103 0.000 0.000
15 47.003 -0.238 -0.148 0.000 0.000
16 43.361 2.090 -0.149 0.000 0.000
17 44.571 -2.183 -0.046 0.000 0.000
18 41.648 0.183 6.128 0.000 0.000
19 46.144 -0.194 -0.841 0.000 0.000
20 45.515 4.397 0.026 0.000 0.000
21 45.543 3.984 -0.019 0.000 0.000
22 47.935 -4.148 0.232 0.000 0.000
23 47.963 -4.561 0.187 0.000 0.000
24 42.090 0.583 12.581 0.000 0.000
25 42.118 0.170 12.537 0.000 0.000
26 51.081 -0.170 -1.358 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 194 of 352

27 51.110 -0.583 -1.403 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 13.195 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 13.333 ft Governing Load Case : #9

Width (W2) = 13.333 ft Governing Load Case : #9

Depth (D2) = 1.000 ft Governing Load Case : #9

Area (A2) = 177.778 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

27 0.4425 0.4396 0.4325 0.4354 0.000

26 0.4412 0.4403 0.4335 0.4343 0.000

11 0.4363 0.4362 0.4370 0.4371 0.000

11 0.4363 0.4362 0.4370 0.4371 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

27 0.4425 0.4396 0.4325 0.4354

26 0.4412 0.4403 0.4335 0.4343

11 0.4363 0.4362 0.4370 0.4371

11 0.4363 0.4362 0.4370 0.4371

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 195 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 3715.175 293.250 3909.999 49535.661

2 129.862 596.455 7952.740 1731.492

3 76.646 2057.760 27436.794 1021.946

4 353.628 970.392 12938.556 4715.040

5 167.310 11796.043 157280.567 2230.804

6 2578.550 84.191 1122.540 34380.665

7 4.911 446.426 5952.349 65.486

8 5.064 137.369 1831.592 67.515

9 47.162 1.519 20.248 628.823

10 66.949 16.421 218.945 892.660

11 3266.344 257.823 3437.636 43551.257

12 126.875 435.979 5813.055 1691.669

13 103.394 2551.803 34024.037 1378.592

14 210.696 357.285 4763.800 2809.285

15 154.755 249.292 3323.891 2063.394

16 16.756 234.413 3125.511 223.407

17 16.318 767.755 10236.729 217.567

18 186.781 5.574 74.316 2490.409

19 187.692 43.263 576.845 2502.556

20 8.208 1387.430 18499.073 109.443

21 9.062 1931.904 25758.716 120.830

22 8.992 160.807 2144.089 119.894

23 8.181 199.270 2656.930 109.085

24 58.940 2.732 36.433 785.871

25 201.724 2.743 36.578 2689.649

26 228.126 28.621 381.618 3041.683

27 66.683 27.720 369.594 889.105

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 2.635 kip
Governing Restoring Force : 12.943 kip
Minimum Sliding Ratio for the Critical Load Case : 4.911

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 196 of 352

Critical Load Case for Overturning about X-Direction : 9


Governing Overturning Moment : 7.818 kip-ft
Governing Resisting Moment : 158.300 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 20.248

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 7.818 kip
Governing Restoring Force : 11.873 kip
Minimum Sliding Ratio for the Critical Load Case : 1.519
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -2.635 kip-ft
Governing Resisting Moment : 172.572 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 65.486

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 49.580 kip, Load Case # 27

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 197 of 352

From ACI Cl.11.3.1.1, Vc = 161.909 kip

Distance along X to design for shear,


Dx = 5.180 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 121.431 kip

Critical load case for Vux is # 27 20.005 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 161.909 kip

Distance along X to design for shear, Dz = 5.180 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 121.431 kip

Critical load case for Vuz is # 27 19.918 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 198 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 27

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.846 ft
a distance, Dx =

Ultimate moment, 65.750 kip-ft

Nominal moment capacity, Mn = 73.056 kip-ft

Required = 0.00145

Since OK

Area of Steel Required, As = 2.304 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 7.681 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 199 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.596 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 21

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.310 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00164

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 7.681 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 27

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.846 ft
a distance, Dz =

Ultimate moment, 66.085 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 200 of 352

Nominal moment capacity, Mn = 73.427 kip-ft

Required = 0.00160

Since OK

Area of Steel Required, As = 2.196 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.350 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.596 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00172

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 15.350 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 201 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.846 ft
at a distance, Dx =

Ultimate moment, 34.181 kip-ft

Nominal moment capacity, Mn = 37.979 kip-ft

Required = 0.00082

Since OK

Area of Steel Required, As = 2.196 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 202 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.846 ft
at a distance, Dx =

Ultimate moment, 34.181 kip-ft

Nominal moment capacity, Mn = 37.979 kip-ft

Required = 0.00075

Since OK

Area of Steel Required, As = 2.304 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.681 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 45

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 203 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 204 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 205 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 56.769 -0.680 -1.311 0.000 0.000
2 6.839 -0.390 -0.467 0.000 0.000
3 2.679 0.107 0.018 0.000 0.000
4 5.412 0.052 0.063 0.000 0.000
5 1.992 -0.041 -0.003 0.000 0.000
6 6.894 0.414 -0.339 0.000 0.000
7 9.389 4.206 0.179 0.000 0.000
8 -8.906 -4.184 0.030 0.000 0.000
9 15.222 -0.041 3.451 0.000 0.000
10 -14.967 0.032 -3.494 0.000 0.000
11 79.476 -0.952 -1.836 0.000 0.000
12 85.700 -1.298 -2.494 0.000 0.000
13 84.515 -0.354 -1.612 0.000 0.000
14 87.984 -0.584 -2.585 0.000 0.000
15 87.243 0.006 -2.034 0.000 0.000
16 86.664 3.211 -1.972 0.000 0.000
17 72.027 -3.500 -2.091 0.000 0.000
18 91.330 -0.186 0.645 0.000 0.000
19 67.178 -0.128 -4.911 0.000 0.000
20 95.424 5.689 -1.925 0.000 0.000
21 94.683 6.279 -1.375 0.000 0.000
22 66.151 -7.734 -2.164 0.000 0.000
23 65.411 -7.144 -1.613 0.000 0.000
24 104.756 -1.105 3.309 0.000 0.000
25 104.015 -0.515 3.860 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 206 of 352

26 56.453 -0.989 -7.802 0.000 0.000


27 55.713 -0.399 -7.251 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 56.769 -0.680 -1.311 0.000 0.000
2 6.839 -0.390 -0.467 0.000 0.000
3 2.679 0.107 0.018 0.000 0.000
4 5.412 0.052 0.063 0.000 0.000
5 1.992 -0.041 -0.003 0.000 0.000
6 6.894 0.414 -0.339 0.000 0.000
7 9.389 4.206 0.179 0.000 0.000
8 -8.906 -4.184 0.030 0.000 0.000
9 15.222 -0.041 3.451 0.000 0.000
10 -14.967 0.032 -3.494 0.000 0.000
11 79.476 -0.952 -1.836 0.000 0.000
12 85.700 -1.298 -2.494 0.000 0.000
13 84.515 -0.354 -1.612 0.000 0.000
14 87.984 -0.584 -2.585 0.000 0.000
15 87.243 0.006 -2.034 0.000 0.000
16 86.664 3.211 -1.972 0.000 0.000
17 72.027 -3.500 -2.091 0.000 0.000
18 91.330 -0.186 0.645 0.000 0.000
19 67.178 -0.128 -4.911 0.000 0.000
20 95.424 5.689 -1.925 0.000 0.000
21 94.683 6.279 -1.375 0.000 0.000
22 66.151 -7.734 -2.164 0.000 0.000
23 65.411 -7.144 -1.613 0.000 0.000
24 104.756 -1.105 3.309 0.000 0.000
25 104.015 -0.515 3.860 0.000 0.000
26 56.453 -0.989 -7.802 0.000 0.000
27 55.713 -0.399 -7.251 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 26.607 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 13.167 ft Governing Load Case : # 10

Width (W2) = 13.167 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 173.361 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 207 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

24 0.7485 0.7427 0.7601 0.7659 0.000

24 0.7485 0.7427 0.7601 0.7659 0.000

24 0.7485 0.7427 0.7601 0.7659 0.000

24 0.7485 0.7427 0.7601 0.7659 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

24 0.7485 0.7427 0.7601 0.7659

24 0.7485 0.7427 0.7601 0.7659

24 0.7485 0.7427 0.7601 0.7659

24 0.7485 0.7427 0.7601 0.7659

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 60.862 31.566 415.622 801.343

2 42.109 35.176 463.151 554.438

3 133.698 780.924 10282.164 1760.355

4 303.407 248.471 3271.530 3994.853

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 208 of 352

5 342.094 5479.374 72145.086 4504.237

6 39.707 48.528 638.957 522.805

7 4.208 98.763 1300.385 55.405

8 2.043 282.438 3718.770 26.904

9 502.692 5.973 78.644 6618.776

10 173.657 1.579 20.797 2286.484

11 55.399 28.733 378.316 729.414

12 43.019 22.396 294.882 566.413

13 155.916 34.275 451.282 2052.894

14 97.576 22.048 290.294 1284.756

15 9693.817 27.838 366.531 127635.254

16 17.543 28.563 376.074 230.978

17 14.003 23.436 308.580 184.377

18 315.408 90.928 1197.215 4152.874

19 364.632 9.488 124.921 4800.984

20 10.672 31.532 415.167 140.514

21 9.610 43.902 578.041 126.536

22 5.958 21.295 280.386 78.445

23 6.398 28.341 373.153 84.240

24 59.147 19.755 260.111 778.766

25 126.122 16.840 221.724 1660.609

26 41.690 5.284 69.575 548.921

27 102.403 5.635 74.189 1348.307

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -4.184 kip
Governing Restoring Force : 8.549 kip
Minimum Sliding Ratio for the Critical Load Case : 2.043
Critical Load Case for Overturning about X-Direction : 10
Governing Overturning Moment : -3.494 kip-ft
Governing Resisting Moment : 72.661 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 20.797

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -3.494 kip
Governing Restoring Force : 5.519 kip
Minimum Sliding Ratio for the Critical Load Case : 1.579
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 4.184 kip-ft
Governing Resisting Moment : 112.562 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 26.904

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 209 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 101.540 kip, Load Case # 24

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 159.885 kip

Distance along X to design for shear,


Dx = 8.070 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 119.914 kip

Critical load case for Vux is # 24 40.906 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 210 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 159.885 kip

Distance along X to design for shear, Dz = 5.096 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 119.914 kip

Critical load case for Vuz is # 24 40.668 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 24

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 211 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.763 ft
a distance, Dx =

Ultimate moment, 132.576 kip-ft

Nominal moment capacity, Mn = 147.307 kip-ft

Required = 0.00299

Since OK

Area of Steel Required, As = 3.783 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 8.417 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 8.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.513 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 19

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 3.800 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.729 ft
=

Reinforcement ratio, = 0.00275

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 8.417 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 212 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 24

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.763 ft
a distance, Dz =

Ultimate moment, 133.474 kip-ft

Nominal moment capacity, Mn = 148.305 kip-ft

Required = 0.00344

Since OK

Area of Steel Required, As = 4.079 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 4.098 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 4.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 213 of 352

Available development length for bars, DL


5.513 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 38

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 4.180 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.655 ft
=

Reinforcement ratio, = 0.00336

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 4.098 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.763 ft
at a distance, Dx =

Ultimate moment, 32.798 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 214 of 352

Nominal moment capacity, Mn = 36.443 kip-ft

Required = 0.00080

Since OK

Area of Steel Required, As = 2.169 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.763 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 215 of 352

Ultimate moment, 32.798 kip-ft

Nominal moment capacity, Mn = 36.443 kip-ft

Required = 0.00073

Since OK

Area of Steel Required, As = 2.275 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.581 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 46

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 216 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 217 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 218 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 58.130 -0.314 3.347 0.000 0.000
2 12.198 0.278 3.234 0.000 0.000
3 3.854 -0.579 -0.115 0.000 0.000
4 9.985 -0.012 -0.585 0.000 0.000
5 2.899 0.078 0.008 0.000 0.000
6 -0.303 0.055 -0.121 0.000 0.000
7 -0.262 3.518 0.086 0.000 0.000
8 0.275 -3.457 0.041 0.000 0.000
9 -0.246 0.196 2.539 0.000 0.000
10 0.530 -0.241 -2.543 0.000 0.000
11 81.382 -0.439 4.686 0.000 0.000
12 93.761 0.221 9.143 0.000 0.000
13 91.747 -1.295 2.836 0.000 0.000
14 84.370 0.068 7.065 0.000 0.000
15 83.111 -0.879 3.123 0.000 0.000
16 69.062 2.527 3.892 0.000 0.000
17 69.492 -3.054 3.856 0.000 0.000
18 69.075 -0.131 5.854 0.000 0.000
19 69.696 -0.481 1.789 0.000 0.000
20 84.283 5.636 7.336 0.000 0.000
21 83.024 4.689 3.394 0.000 0.000
22 85.143 -5.524 7.263 0.000 0.000
23 83.884 -6.472 3.322 0.000 0.000
24 84.308 0.321 11.260 0.000 0.000
25 83.049 -0.627 7.318 0.000 0.000
26 85.551 -0.379 3.129 0.000 0.000
27 84.292 -1.327 -0.812 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 58.130 -0.314 3.347 0.000 0.000
2 12.198 0.278 3.234 0.000 0.000
3 3.854 -0.579 -0.115 0.000 0.000
4 9.985 -0.012 -0.585 0.000 0.000
5 2.899 0.078 0.008 0.000 0.000
6 -0.303 0.055 -0.121 0.000 0.000
7 -0.262 3.518 0.086 0.000 0.000
8 0.275 -3.457 0.041 0.000 0.000
9 -0.246 0.196 2.539 0.000 0.000
10 0.530 -0.241 -2.543 0.000 0.000
11 81.382 -0.439 4.686 0.000 0.000
12 93.761 0.221 9.143 0.000 0.000
13 91.747 -1.295 2.836 0.000 0.000
14 84.370 0.068 7.065 0.000 0.000
15 83.111 -0.879 3.123 0.000 0.000
16 69.062 2.527 3.892 0.000 0.000
17 69.492 -3.054 3.856 0.000 0.000
18 69.075 -0.131 5.854 0.000 0.000
19 69.696 -0.481 1.789 0.000 0.000
20 84.283 5.636 7.336 0.000 0.000
21 83.024 4.689 3.394 0.000 0.000
22 85.143 -5.524 7.263 0.000 0.000
23 83.884 -6.472 3.322 0.000 0.000
24 84.308 0.321 11.260 0.000 0.000
25 83.049 -0.627 7.318 0.000 0.000
26 85.551 -0.379 3.129 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 219 of 352

27 84.292 -1.327 -0.812 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 23.858 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 8.500 ft Governing Load Case : #7

Width (W2) = 8.500 ft Governing Load Case : #7

Depth (D2) = 1.000 ft Governing Load Case : #7

Area (A2) = 72.250 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

13 1.4048 1.3795 1.4349 1.4602 0.000

13 1.4048 1.3795 1.4349 1.4602 0.000

12 1.3562 1.3606 1.5392 1.5349 0.000

12 1.3562 1.3606 1.5392 1.5349 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

13 1.4048 1.3795 1.4349 1.4602

13 1.4048 1.3795 1.4349 1.4602

12 1.3562 1.3606 1.5392 1.5349

12 1.3562 1.3606 1.5392 1.5349

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 220 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 109.855 10.303 87.573 933.764

2 41.452 3.562 30.277 352.342

3 12.690 63.667 541.167 107.862

4 836.039 17.807 151.356 7106.330

5 87.675 855.250 7269.625 745.239

6 95.180 43.581 370.443 809.028

7 1.503 61.139 519.685 12.775

8 1.607 135.134 1148.639 13.661

9 27.005 2.086 17.729 229.541

10 23.546 2.235 19.001 200.144

11 104.922 9.840 83.641 891.841

12 236.744 5.720 48.624 2012.327

13 39.603 18.086 153.734 336.627

14 699.375 6.738 57.275 5944.689

15 53.412 15.041 127.850 454.000

16 15.812 10.264 87.243 134.404

17 13.152 10.416 88.538 111.794

18 304.405 6.825 58.014 2587.445

19 83.671 22.508 191.319 711.205

20 8.438 6.483 55.107 71.723

21 10.009 13.826 117.522 85.075

22 8.687 6.607 56.160 73.841

23 7.318 14.258 121.189 62.203

24 148.229 4.225 35.912 1259.945

25 74.918 6.415 54.523 636.803

26 127.148 15.401 130.904 1080.754

27 35.855 58.562 497.775 304.769

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 3.518 kip
Governing Restoring Force : 5.288 kip
Minimum Sliding Ratio for the Critical Load Case : 1.503

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 221 of 352

Critical Load Case for Overturning about X-Direction : 9


Governing Overturning Moment : 2.539 kip-ft
Governing Resisting Moment : 45.012 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 17.729

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 2.539 kip
Governing Restoring Force : 5.296 kip
Minimum Sliding Ratio for the Critical Load Case : 2.086
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -3.518 kip-ft
Governing Resisting Moment : 44.946 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 12.775

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 86.854 kip, Load Case # 12

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 222 of 352

From ACI Cl.11.3.1.1, Vc = 103.217 kip

Distance along X to design for shear,


Dx = 5.737 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 77.413 kip

Critical load case for Vux is # 12 31.895 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 103.217 kip

Distance along X to design for shear, Dz = 5.737 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 77.413 kip

Critical load case for Vuz is # 12 30.513 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 223 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 12

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 3.430 ft
a distance, Dx =

Ultimate moment, 64.959 kip-ft

Nominal moment capacity, Mn = 72.176 kip-ft

Required = 0.00226

Since OK

Area of Steel Required, As = 1.841 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 18.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 224 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.180 ft
=
Try bar size #5 Area of one bar = 0.310 in2

Number of bars required, Nbar = 6

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.860 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.724 ft
=

Reinforcement ratio, = 0.00210

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 18.000 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 12

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 3.430 ft
a distance, Dz =

Ultimate moment, 68.147 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 225 of 352

Nominal moment capacity, Mn = 75.719 kip-ft

Required = 0.00280

Since OK

Area of Steel Required, As = 2.105 in2

Selected Bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.896 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 15.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.180 ft
=
Try bar size #5 Area of one bar = 0.310 in2

Number of bars required, Nbar = 7

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.170 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.645 ft
=

Reinforcement ratio, = 0.00275

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 15.896 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 226 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.430 ft
at a distance, Dx =

Ultimate moment, 7.499 kip-ft

Nominal moment capacity, Mn = 8.332 kip-ft

Required = 0.00028

Since OK

Area of Steel Required, As = 1.400 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.917 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 227 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.430 ft
at a distance, Dx =

Ultimate moment, 7.499 kip-ft

Nominal moment capacity, Mn = 8.332 kip-ft

Required = 0.00026

Since OK

Area of Steel Required, As = 1.469 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.356 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 47

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 228 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 229 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 230 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 54.257 0.324 2.775 0.000 0.000
2 2.370 0.270 0.052 0.000 0.000
3 13.025 0.035 2.824 0.000 0.000
4 1.394 -0.013 -0.008 0.000 0.000
5 11.498 -0.044 -0.569 0.000 0.000
6 -0.303 -0.055 -0.121 0.000 0.000
7 0.275 3.457 0.041 0.000 0.000
8 -0.262 -3.518 0.086 0.000 0.000
9 -0.246 -0.196 2.539 0.000 0.000
10 0.530 0.241 -2.543 0.000 0.000
11 75.960 0.454 3.884 0.000 0.000
12 87.146 0.723 2.443 0.000 0.000
13 88.029 0.397 7.775 0.000 0.000
14 78.493 0.526 2.620 0.000 0.000
15 79.044 0.323 5.952 0.000 0.000
16 64.845 3.066 3.169 0.000 0.000
17 64.415 -2.514 3.205 0.000 0.000
18 64.428 0.144 5.167 0.000 0.000
19 65.049 0.494 1.102 0.000 0.000
20 79.265 6.119 2.819 0.000 0.000
21 79.817 5.915 6.151 0.000 0.000
22 78.406 -5.042 2.891 0.000 0.000
23 78.958 -5.246 6.224 0.000 0.000
24 78.431 0.274 6.815 0.000 0.000
25 78.983 0.070 10.148 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 231 of 352

26 79.674 0.974 -1.315 0.000 0.000


27 80.226 0.770 2.017 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 54.257 0.324 2.775 0.000 0.000
2 2.370 0.270 0.052 0.000 0.000
3 13.025 0.035 2.824 0.000 0.000
4 1.394 -0.013 -0.008 0.000 0.000
5 11.498 -0.044 -0.569 0.000 0.000
6 -0.303 -0.055 -0.121 0.000 0.000
7 0.275 3.457 0.041 0.000 0.000
8 -0.262 -3.518 0.086 0.000 0.000
9 -0.246 -0.196 2.539 0.000 0.000
10 0.530 0.241 -2.543 0.000 0.000
11 75.960 0.454 3.884 0.000 0.000
12 87.146 0.723 2.443 0.000 0.000
13 88.029 0.397 7.775 0.000 0.000
14 78.493 0.526 2.620 0.000 0.000
15 79.044 0.323 5.952 0.000 0.000
16 64.845 3.066 3.169 0.000 0.000
17 64.415 -2.514 3.205 0.000 0.000
18 64.428 0.144 5.167 0.000 0.000
19 65.049 0.494 1.102 0.000 0.000
20 79.265 6.119 2.819 0.000 0.000
21 79.817 5.915 6.151 0.000 0.000
22 78.406 -5.042 2.891 0.000 0.000
23 78.958 -5.246 6.224 0.000 0.000
24 78.431 0.274 6.815 0.000 0.000
25 78.983 0.070 10.148 0.000 0.000
26 79.674 0.974 -1.315 0.000 0.000
27 80.226 0.770 2.017 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 22.425 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 8.500 ft Governing Load Case : #8

Width (W2) = 8.500 ft Governing Load Case : #8

Depth (D2) = 1.000 ft Governing Load Case : #8

Area (A2) = 72.250 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 232 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

12 1.3252 1.3394 1.3871 1.3730 0.000

12 1.3252 1.3394 1.3871 1.3730 0.000

13 1.2885 1.2963 1.4482 1.4405 0.000

13 1.2885 1.2963 1.4482 1.4405 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

12 1.3252 1.3394 1.3871 1.3730

12 1.3252 1.3394 1.3871 1.3730

13 1.2885 1.2963 1.4482 1.4405

13 1.2885 1.2963 1.4482 1.4405

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 100.322 11.730 99.709 852.740

2 24.465 125.978 1070.811 207.952

3 345.243 4.225 35.911 2934.563

4 489.214 774.635 6584.401 4158.320

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 233 of 352

5 252.386 19.639 166.933 2145.284

6 95.180 43.581 370.443 809.028

7 1.607 135.134 1148.639 13.661

8 1.503 61.139 519.685 12.775

9 27.005 2.086 17.729 229.541

10 23.546 2.235 19.001 200.143

11 95.550 11.172 94.966 812.177

12 67.788 20.053 170.448 576.199

13 124.537 6.358 54.042 1058.566

14 84.844 17.048 144.910 721.172

15 139.212 7.550 64.176 1183.302

16 12.340 11.941 101.497 104.892

17 14.967 11.739 99.778 127.223

18 261.538 7.283 61.904 2223.070

19 76.827 34.430 292.652 653.027

20 7.363 15.983 135.858 62.584

21 7.663 7.369 62.636 65.135

22 8.850 15.433 131.183 75.225

23 8.559 7.214 61.319 72.752

24 163.159 6.549 55.668 1386.851

25 642.054 4.426 37.618 5457.460

26 46.485 34.406 292.454 395.126

27 59.137 22.573 191.869 502.666

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -3.518 kip
Governing Restoring Force : 5.288 kip
Minimum Sliding Ratio for the Critical Load Case : 1.503
Critical Load Case for Overturning about X-Direction : 9
Governing Overturning Moment : 2.539 kip-ft
Governing Resisting Moment : 45.012 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 17.729

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 2.539 kip
Governing Restoring Force : 5.296 kip
Minimum Sliding Ratio for the Critical Load Case : 2.086
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 3.518 kip-ft
Governing Resisting Moment : 44.946 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 12.775

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 234 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 81.544 kip, Load Case # 13

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 103.217 kip

Distance along X to design for shear,


Dx = 5.737 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 77.413 kip

Critical load case for Vux is # 13 29.820 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 235 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 103.217 kip

Distance along X to design for shear, Dz = 5.737 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 77.413 kip

Critical load case for Vuz is # 13 28.677 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 13

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 236 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 3.430 ft
a distance, Dx =

Ultimate moment, 61.055 kip-ft

Nominal moment capacity, Mn = 67.839 kip-ft

Required = 0.00212

Since OK

Area of Steel Required, As = 1.728 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 6.375 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 6.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.180 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 16

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.760 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00196

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 6.375 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 237 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 13

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 3.430 ft
a distance, Dz =

Ultimate moment, 63.692 kip-ft

Nominal moment capacity, Mn = 70.769 kip-ft

Required = 0.00244

Since OK

Area of Steel Required, As = 1.897 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 5.625 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 5.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 238 of 352

Available development length for bars, DL


3.180 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 18

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.980 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00243

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 5.625 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.430 ft
at a distance, Dx =

Ultimate moment, 7.499 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 239 of 352

Nominal moment capacity, Mn = 8.332 kip-ft

Required = 0.00028

Since OK

Area of Steel Required, As = 1.400 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.917 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.430 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 240 of 352

Ultimate moment, 7.499 kip-ft

Nominal moment capacity, Mn = 8.332 kip-ft

Required = 0.00026

Since OK

Area of Steel Required, As = 1.469 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.356 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 48

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 241 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 242 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 243 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 54.076 0.689 -1.219 0.000 0.000
2 4.812 -0.099 -0.419 0.000 0.000
3 4.034 0.385 0.025 0.000 0.000
4 4.234 0.043 0.064 0.000 0.000
5 2.761 -0.043 -0.008 0.000 0.000
6 6.894 -0.414 -0.339 0.000 0.000
7 -8.906 4.184 0.030 0.000 0.000
8 9.389 -4.206 0.179 0.000 0.000
9 15.222 0.041 3.451 0.000 0.000
10 -14.967 -0.032 -3.494 0.000 0.000
11 75.707 0.965 -1.706 0.000 0.000
12 80.454 0.394 -2.315 0.000 0.000
13 81.568 1.304 -1.490 0.000 0.000
14 83.493 0.023 -2.432 0.000 0.000
15 84.190 0.592 -1.916 0.000 0.000
16 68.796 3.511 -1.980 0.000 0.000
17 83.432 -3.200 -1.861 0.000 0.000
18 88.099 0.197 0.756 0.000 0.000
19 63.947 0.139 -4.800 0.000 0.000
20 61.661 7.173 -2.010 0.000 0.000
21 62.357 7.742 -1.495 0.000 0.000
22 90.934 -6.250 -1.772 0.000 0.000
23 91.630 -5.681 -1.256 0.000 0.000
24 100.266 0.544 3.463 0.000 0.000
25 100.962 1.113 3.979 0.000 0.000
26 51.963 0.428 -7.649 0.000 0.000
27 52.659 0.997 -7.133 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 54.076 0.689 -1.219 0.000 0.000
2 4.812 -0.099 -0.419 0.000 0.000
3 4.034 0.385 0.025 0.000 0.000
4 4.234 0.043 0.064 0.000 0.000
5 2.761 -0.043 -0.008 0.000 0.000
6 6.894 -0.414 -0.339 0.000 0.000
7 -8.906 4.184 0.030 0.000 0.000
8 9.389 -4.206 0.179 0.000 0.000
9 15.222 0.041 3.451 0.000 0.000
10 -14.967 -0.032 -3.494 0.000 0.000
11 75.707 0.965 -1.706 0.000 0.000
12 80.454 0.394 -2.315 0.000 0.000
13 81.568 1.304 -1.490 0.000 0.000
14 83.493 0.023 -2.432 0.000 0.000
15 84.190 0.592 -1.916 0.000 0.000
16 68.796 3.511 -1.980 0.000 0.000
17 83.432 -3.200 -1.861 0.000 0.000
18 88.099 0.197 0.756 0.000 0.000
19 63.947 0.139 -4.800 0.000 0.000
20 61.661 7.173 -2.010 0.000 0.000
21 62.357 7.742 -1.495 0.000 0.000
22 90.934 -6.250 -1.772 0.000 0.000
23 91.630 -5.681 -1.256 0.000 0.000
24 100.266 0.544 3.463 0.000 0.000
25 100.962 1.113 3.979 0.000 0.000
26 51.963 0.428 -7.649 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 244 of 352

27 52.659 0.997 -7.133 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 25.659 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 13.167 ft Governing Load Case : # 10

Width (W2) = 13.167 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 173.361 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

25 0.7190 0.7248 0.7458 0.7399 0.000

25 0.7190 0.7248 0.7458 0.7399 0.000

25 0.7190 0.7248 0.7458 0.7399 0.000

25 0.7190 0.7248 0.7458 0.7399 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

25 0.7190 0.7248 0.7458 0.7399

25 0.7190 0.7248 0.7458 0.7399

25 0.7190 0.7248 0.7458 0.7399

25 0.7190 0.7248 0.7458 0.7399

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 245 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 58.084 32.858 432.627 764.778

2 155.940 36.787 484.361 2053.216

3 39.039 596.829 7858.254 514.007

4 354.129 237.669 3129.312 4662.701

5 338.048 1779.589 23431.260 4450.964

6 39.707 48.528 638.957 522.805

7 2.043 282.438 3718.771 26.904

8 4.208 98.763 1300.385 55.405

9 502.692 5.973 78.644 6618.776

10 173.657 1.579 20.797 2286.483

11 52.695 29.809 392.488 693.822

12 135.126 22.994 302.760 1779.158

13 41.248 36.104 475.375 543.101

14 2375.366 22.516 296.460 31275.651

15 93.097 28.758 378.653 1225.774

16 13.499 23.934 315.136 177.731

17 17.099 29.398 387.075 225.139

18 289.300 75.443 993.339 3809.122

19 323.618 9.370 123.378 4260.975

20 6.111 21.804 287.088 80.459

21 5.707 29.561 389.216 75.140

22 9.355 32.996 434.443 123.171

23 10.353 46.817 616.428 136.309

24 115.984 18.231 240.046 1527.124

25 57.032 15.956 210.085 750.919

26 91.107 5.097 67.106 1199.578

27 39.464 5.514 72.600 519.603

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 4.184 kip
Governing Restoring Force : 8.549 kip
Minimum Sliding Ratio for the Critical Load Case : 2.043

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 246 of 352

Critical Load Case for Overturning about X-Direction : 10


Governing Overturning Moment : -3.494 kip-ft
Governing Resisting Moment : 72.661 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 20.797

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -3.494 kip
Governing Restoring Force : 5.519 kip
Minimum Sliding Ratio for the Critical Load Case : 1.579
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -4.184 kip-ft
Governing Resisting Moment : 112.562 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 26.904

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 97.862 kip, Load Case # 25

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 247 of 352

From ACI Cl.11.3.1.1, Vc = 159.885 kip

Distance along X to design for shear,


Dx = 8.070 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 119.914 kip

Critical load case for Vux is # 25 39.510 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 159.885 kip

Distance along X to design for shear, Dz = 8.070 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 119.914 kip

Critical load case for Vuz is # 25 39.200 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 248 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 25

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.763 ft
a distance, Dx =

Ultimate moment, 127.794 kip-ft

Nominal moment capacity, Mn = 141.994 kip-ft

Required = 0.00288

Since OK

Area of Steel Required, As = 3.642 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 13.761 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 13.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 249 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.513 ft
=
Try bar size #5 Area of one bar = 0.310 in2

Number of bars required, Nbar = 12

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 3.720 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.724 ft
=

Reinforcement ratio, = 0.00271

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 13.761 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 25

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.763 ft
a distance, Dz =

Ultimate moment, 128.962 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 250 of 352

Nominal moment capacity, Mn = 143.291 kip-ft

Required = 0.00344

Since OK

Area of Steel Required, As = 4.007 in2

Selected Bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 12.615 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 12.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.513 ft
=
Try bar size #5 Area of one bar = 0.310 in2

Number of bars required, Nbar = 13

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 4.030 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.645 ft
=

Reinforcement ratio, = 0.00330

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 12.615 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 251 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.763 ft
at a distance, Dx =

Ultimate moment, 32.798 kip-ft

Nominal moment capacity, Mn = 36.443 kip-ft

Required = 0.00080

Since OK

Area of Steel Required, As = 2.169 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 252 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.763 ft
at a distance, Dx =

Ultimate moment, 32.798 kip-ft

Nominal moment capacity, Mn = 36.443 kip-ft

Required = 0.00073

Since OK

Area of Steel Required, As = 2.275 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.581 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 49

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 253 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 254 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 255 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 29.205 -0.108 0.802 0.000 0.000
2 0.708 0.008 0.302 0.000 0.000
3 3.991 -0.003 0.077 0.000 0.000
4 0.715 -0.019 -0.079 0.000 0.000
5 3.766 -0.018 -0.024 0.000 0.000
6 4.008 0.195 -0.990 0.000 0.000
7 7.017 2.832 0.872 0.000 0.000
8 -2.713 -0.818 -0.186 0.000 0.000
9 -11.872 0.119 3.869 0.000 0.000
10 11.909 -0.023 -3.871 0.000 0.000
11 40.887 -0.151 1.123 0.000 0.000
12 44.208 -0.047 0.912 0.000 0.000
13 44.580 -0.066 0.465 0.000 0.000
14 45.933 0.173 -0.343 0.000 0.000
15 46.165 0.162 -0.622 0.000 0.000
16 47.072 2.448 0.077 0.000 0.000
17 39.288 -0.471 -0.770 0.000 0.000
18 31.961 0.278 2.475 0.000 0.000
19 50.986 0.164 -3.717 0.000 0.000
20 52.750 4.490 2.140 0.000 0.000
21 52.983 4.478 1.861 0.000 0.000
22 37.182 -1.350 0.447 0.000 0.000
23 37.415 -1.361 0.168 0.000 0.000
24 22.528 0.150 6.935 0.000 0.000
25 22.760 0.138 6.656 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 256 of 352

26 60.578 -0.078 -5.448 0.000 0.000


27 60.811 -0.090 -5.727 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 29.205 -0.108 0.802 0.000 0.000
2 0.708 0.008 0.302 0.000 0.000
3 3.991 -0.003 0.077 0.000 0.000
4 0.715 -0.019 -0.079 0.000 0.000
5 3.766 -0.018 -0.024 0.000 0.000
6 4.008 0.195 -0.990 0.000 0.000
7 7.017 2.832 0.872 0.000 0.000
8 -2.713 -0.818 -0.186 0.000 0.000
9 -11.872 0.119 3.869 0.000 0.000
10 11.909 -0.023 -3.871 0.000 0.000
11 40.887 -0.151 1.123 0.000 0.000
12 44.208 -0.047 0.912 0.000 0.000
13 44.580 -0.066 0.465 0.000 0.000
14 45.933 0.173 -0.343 0.000 0.000
15 46.165 0.162 -0.622 0.000 0.000
16 47.072 2.448 0.077 0.000 0.000
17 39.288 -0.471 -0.770 0.000 0.000
18 31.961 0.278 2.475 0.000 0.000
19 50.986 0.164 -3.717 0.000 0.000
20 52.750 4.490 2.140 0.000 0.000
21 52.983 4.478 1.861 0.000 0.000
22 37.182 -1.350 0.447 0.000 0.000
23 37.415 -1.361 0.168 0.000 0.000
24 22.528 0.150 6.935 0.000 0.000
25 22.760 0.138 6.656 0.000 0.000
26 60.578 -0.078 -5.448 0.000 0.000
27 60.811 -0.090 -5.727 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 15.620 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 12.667 ft Governing Load Case : #9

Width (W2) = 12.667 ft Governing Load Case : #9

Depth (D2) = 1.000 ft Governing Load Case : #9

Area (A2) = 160.444 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 257 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

27 0.5462 0.5457 0.5118 0.5124 0.000

27 0.5462 0.5457 0.5118 0.5124 0.000

27 0.5462 0.5457 0.5118 0.5124 0.000

27 0.5462 0.5457 0.5118 0.5124 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

27 0.5462 0.5457 0.5118 0.5124

27 0.5462 0.5457 0.5118 0.5124

27 0.5462 0.5457 0.5118 0.5124

27 0.5462 0.5457 0.5118 0.5124

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 246.683 33.192 420.429 3124.651

2 1510.513 41.080 520.341 19133.167

3 5290.625 181.726 2301.864 67014.578

4 669.688 156.299 1979.791 8482.714

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 258 of 352

5 795.005 577.524 7315.306 10070.067

6 71.918 14.185 179.682 910.964

7 5.487 17.829 225.830 69.508

8 13.058 57.250 725.160 165.396

9 51.123 1.576 19.963 647.562

10 780.514 4.647 58.861 9886.506

11 214.842 28.907 366.161 2721.330

12 728.413 37.427 474.073 9226.562

13 521.428 73.834 935.233 6604.754

14 201.819 102.077 1292.970 2556.373

15 217.341 56.420 714.657 2752.984

16 14.527 461.598 5846.910 184.010

17 67.198 41.166 521.431 851.174

18 100.720 11.321 143.395 1275.789

19 228.419 10.096 127.880 2893.308

20 8.554 17.945 227.298 108.348

21 8.602 20.703 262.232 108.963

22 22.693 68.473 867.322 287.439

23 22.580 183.277 2321.513 286.019

24 155.795 3.359 42.549 1973.406

25 170.048 3.518 44.558 2153.947

26 541.508 7.769 98.403 6859.100

27 471.506 7.410 93.858 5972.413

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 2.832 kip
Governing Restoring Force : 15.542 kip
Minimum Sliding Ratio for the Critical Load Case : 5.487
Critical Load Case for Overturning about X-Direction : 9
Governing Overturning Moment : 3.869 kip-ft
Governing Resisting Moment : 77.230 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 19.963

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 3.869 kip
Governing Restoring Force : 6.097 kip
Minimum Sliding Ratio for the Critical Load Case : 1.576
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -2.832 kip-ft
Governing Resisting Moment : 196.860 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 69.508

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 259 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 58.794 kip, Load Case # 27

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 153.813 kip

Distance along X to design for shear,


Dx = 4.846 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 115.360 kip

Critical load case for Vux is # 27 23.908 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 260 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 153.813 kip

Distance along X to design for shear, Dz = 4.846 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 115.360 kip

Critical load case for Vuz is # 27 23.277 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 27

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 261 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.513 ft
a distance, Dx =

Ultimate moment, 72.996 kip-ft

Nominal moment capacity, Mn = 81.107 kip-ft

Required = 0.00169

Since OK

Area of Steel Required, As = 2.189 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 14.550 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.263 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.729 ft
=

Reinforcement ratio, = 0.00165

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 14.550 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 262 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 27

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.513 ft
a distance, Dz =

Ultimate moment, 75.270 kip-ft

Nominal moment capacity, Mn = 83.633 kip-ft

Required = 0.00199

Since OK

Area of Steel Required, As = 2.270 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.281 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 263 of 352

Available development length for bars, DL


5.263 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 21

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.310 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.655 ft
=

Reinforcement ratio, = 0.00193

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 7.281 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.513 ft
at a distance, Dx =

Ultimate moment, 28.875 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 264 of 352

Nominal moment capacity, Mn = 32.083 kip-ft

Required = 0.00081

Since OK

Area of Steel Required, As = 1.984 in2

Selected bar Size = #9


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#9 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.513 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 265 of 352

Ultimate moment, 28.875 kip-ft

Nominal moment capacity, Mn = 32.083 kip-ft

Required = 0.00066

Since OK

Area of Steel Required, As = 2.189 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Isolated Footing 50

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 266 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 267 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 268 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 27.058 0.102 0.748 0.000 0.000
2 0.141 0.002 0.182 0.000 0.000
3 4.019 -0.008 0.158 0.000 0.000
4 0.156 0.012 -0.056 0.000 0.000
5 4.021 0.024 -0.041 0.000 0.000
6 4.008 -0.195 -0.990 0.000 0.000
7 -2.713 0.818 -0.186 0.000 0.000
8 7.017 -2.832 0.872 0.000 0.000
9 -11.872 -0.119 3.869 0.000 0.000
10 11.909 0.023 -3.871 0.000 0.000
11 37.881 0.143 1.047 0.000 0.000
12 41.132 0.065 0.630 0.000 0.000
13 41.153 0.032 0.566 0.000 0.000
14 43.044 -0.164 -0.544 0.000 0.000
15 43.057 -0.185 -0.584 0.000 0.000
16 36.712 0.464 -0.835 0.000 0.000
17 44.495 -2.455 0.012 0.000 0.000
18 29.384 -0.285 2.409 0.000 0.000
19 48.410 -0.171 -3.782 0.000 0.000
20 34.294 1.358 0.246 0.000 0.000
21 34.307 1.338 0.207 0.000 0.000
22 49.862 -4.481 1.939 0.000 0.000
23 49.875 -4.502 1.900 0.000 0.000
24 19.639 -0.141 6.734 0.000 0.000
25 19.652 -0.161 6.695 0.000 0.000
26 57.690 0.087 -5.649 0.000 0.000
27 57.703 0.066 -5.689 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 27.058 0.102 0.748 0.000 0.000
2 0.141 0.002 0.182 0.000 0.000
3 4.019 -0.008 0.158 0.000 0.000
4 0.156 0.012 -0.056 0.000 0.000
5 4.021 0.024 -0.041 0.000 0.000
6 4.008 -0.195 -0.990 0.000 0.000
7 -2.713 0.818 -0.186 0.000 0.000
8 7.017 -2.832 0.872 0.000 0.000
9 -11.872 -0.119 3.869 0.000 0.000
10 11.909 0.023 -3.871 0.000 0.000
11 37.881 0.143 1.047 0.000 0.000
12 41.132 0.065 0.630 0.000 0.000
13 41.153 0.032 0.566 0.000 0.000
14 43.044 -0.164 -0.544 0.000 0.000
15 43.057 -0.185 -0.584 0.000 0.000
16 36.712 0.464 -0.835 0.000 0.000
17 44.495 -2.455 0.012 0.000 0.000
18 29.384 -0.285 2.409 0.000 0.000
19 48.410 -0.171 -3.782 0.000 0.000
20 34.294 1.358 0.246 0.000 0.000
21 34.307 1.338 0.207 0.000 0.000
22 49.862 -4.481 1.939 0.000 0.000
23 49.875 -4.502 1.900 0.000 0.000
24 19.639 -0.141 6.734 0.000 0.000
25 19.652 -0.161 6.695 0.000 0.000
26 57.690 0.087 -5.649 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 269 of 352

27 57.703 0.066 -5.689 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 14.843 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 12.667 ft Governing Load Case : #9

Width (W2) = 12.667 ft Governing Load Case : #9

Depth (D2) = 1.000 ft Governing Load Case : #9

Area (A2) = 160.444 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

27 0.5262 0.5266 0.4930 0.4927 0.000

27 0.5262 0.5266 0.4930 0.4927 0.000

26 0.5260 0.5265 0.4931 0.4926 0.000

27 0.5262 0.5266 0.4930 0.4927 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

27 0.5262 0.5266 0.4930 0.4927

27 0.5262 0.5266 0.4930 0.4927

26 0.5260 0.5265 0.4931 0.4926

27 0.5262 0.5266 0.4930 0.4927

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 270 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 250.197 34.170 432.816 3169.167

2 7435.398 66.383 840.857 94181.704

3 1751.282 88.795 1124.737 22182.911

4 981.885 215.583 2730.716 12437.207

5 595.031 345.927 4381.739 7537.065

6 71.918 14.185 179.682 910.965

7 13.058 57.250 725.161 165.396

8 5.487 17.829 225.830 69.508

9 51.123 1.576 19.963 647.562

10 780.514 4.647 58.861 9886.507

11 216.546 29.574 374.602 2742.914

12 498.637 51.770 655.748 6316.074

13 1021.784 57.606 729.673 12942.601

14 204.028 61.699 781.527 2584.359

15 181.046 57.507 728.428 2293.247

16 65.432 36.404 461.115 828.809

17 13.961 2907.055 36822.700 176.842

18 93.739 11.093 140.506 1187.363

19 211.601 9.581 121.358 2680.276

20 21.480 118.486 1500.828 272.077

21 21.821 141.329 1790.173 276.394

22 8.249 19.059 241.419 104.482

23 8.212 19.462 246.516 104.015

24 155.447 3.245 41.103 1969.001

25 135.357 3.265 41.359 1714.527

26 469.255 7.237 91.664 5943.894

27 617.603 7.187 91.038 7822.977

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -2.832 kip
Governing Restoring Force : 15.542 kip
Minimum Sliding Ratio for the Critical Load Case : 5.487

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 271 of 352

Critical Load Case for Overturning about X-Direction : 9


Governing Overturning Moment : 3.869 kip-ft
Governing Resisting Moment : 77.230 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 19.963

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 3.869 kip
Governing Restoring Force : 6.097 kip
Minimum Sliding Ratio for the Critical Load Case : 1.576
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 2.832 kip-ft
Governing Resisting Moment : 196.860 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 69.508

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 55.789 kip, Load Case # 27

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 272 of 352

From ACI Cl.11.3.1.1, Vc = 153.813 kip

Distance along X to design for shear,


Dx = 4.846 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 115.360 kip

Critical load case for Vux is # 27 22.715 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 153.813 kip

Distance along X to design for shear, Dz = 7.820 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 115.360 kip

Critical load case for Vuz is # 27 22.085 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 273 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 27

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 5.513 ft
a distance, Dx =

Ultimate moment, 69.258 kip-ft

Nominal moment capacity, Mn = 76.953 kip-ft

Required = 0.00160

Since OK

Area of Steel Required, As = 2.189 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 14.550 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 274 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.263 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.729 ft
=

Reinforcement ratio, = 0.00165

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 14.550 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 27

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 5.513 ft
a distance, Dz =

Ultimate moment, 71.525 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 275 of 352

Nominal moment capacity, Mn = 79.473 kip-ft

Required = 0.00189

Since OK

Area of Steel Required, As = 2.155 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 14.550 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 14.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


5.263 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 11

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.655 ft
=

Reinforcement ratio, = 0.00184

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 14.550 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 276 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.513 ft
at a distance, Dx =

Ultimate moment, 28.875 kip-ft

Nominal moment capacity, Mn = 32.083 kip-ft

Required = 0.00081

Since OK

Area of Steel Required, As = 1.984 in2

Selected bar Size = #9


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#9 @ 18 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 277 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 5.513 ft
at a distance, Dx =

Ultimate moment, 28.875 kip-ft

Nominal moment capacity, Mn = 32.083 kip-ft

Required = 0.00066

Since OK

Area of Steel Required, As = 2.189 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18 in o.c.

Isolated Footing 51

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 278 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 279 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 280 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 39.220 -0.144 -0.073 0.000 0.000
2 5.782 0.012 0.133 0.000 0.000
3 0.473 -0.008 -0.165 0.000 0.000
4 5.485 -0.033 -0.052 0.000 0.000
5 0.472 -0.015 0.034 0.000 0.000
6 7.608 4.360 0.539 0.000 0.000
7 6.941 1.585 -0.561 0.000 0.000
8 -2.446 -0.473 0.251 0.000 0.000
9 -0.318 0.122 3.127 0.000 0.000
10 0.360 -0.088 -3.127 0.000 0.000
11 54.907 -0.202 -0.102 0.000 0.000
12 60.874 2.000 0.449 0.000 0.000
13 60.400 1.941 -0.165 0.000 0.000
14 65.490 6.798 0.942 0.000 0.000
15 65.194 6.761 0.558 0.000 0.000
16 64.788 8.070 0.326 0.000 0.000
17 57.279 6.424 0.976 0.000 0.000
18 58.981 6.900 3.277 0.000 0.000
19 59.524 6.732 -1.727 0.000 0.000
20 68.227 4.539 -0.549 0.000 0.000
21 67.931 4.502 -0.933 0.000 0.000
22 53.208 1.247 0.750 0.000 0.000
23 52.912 1.209 0.366 0.000 0.000
24 56.612 2.198 5.352 0.000 0.000
25 56.316 2.160 4.968 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 281 of 352

26 57.698 1.862 -4.655 0.000 0.000


27 57.402 1.825 -5.039 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 39.220 -0.144 -0.073 0.000 0.000
2 5.782 0.012 0.133 0.000 0.000
3 0.473 -0.008 -0.165 0.000 0.000
4 5.485 -0.033 -0.052 0.000 0.000
5 0.472 -0.015 0.034 0.000 0.000
6 7.608 4.360 0.539 0.000 0.000
7 6.941 1.585 -0.561 0.000 0.000
8 -2.446 -0.473 0.251 0.000 0.000
9 -0.318 0.122 3.127 0.000 0.000
10 0.360 -0.088 -3.127 0.000 0.000
11 54.907 -0.202 -0.102 0.000 0.000
12 60.874 2.000 0.449 0.000 0.000
13 60.400 1.941 -0.165 0.000 0.000
14 65.490 6.798 0.942 0.000 0.000
15 65.194 6.761 0.558 0.000 0.000
16 64.788 8.070 0.326 0.000 0.000
17 57.279 6.424 0.976 0.000 0.000
18 58.981 6.900 3.277 0.000 0.000
19 59.524 6.732 -1.727 0.000 0.000
20 68.227 4.539 -0.549 0.000 0.000
21 67.931 4.502 -0.933 0.000 0.000
22 53.208 1.247 0.750 0.000 0.000
23 52.912 1.209 0.366 0.000 0.000
24 56.612 2.198 5.352 0.000 0.000
25 56.316 2.160 4.968 0.000 0.000
26 57.698 1.862 -4.655 0.000 0.000
27 57.402 1.825 -5.039 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 17.474 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 8.167 ft Governing Load Case : #9

Width (W2) = 8.167 ft Governing Load Case : #9

Depth (D2) = 1.000 ft Governing Load Case : #9

Area (A2) = 66.694 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 282 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

21 1.1292 1.2284 1.2079 1.1087 0.000

20 1.1290 1.2290 1.2169 1.1169 0.000

14 1.0467 1.1965 1.2172 1.0674 0.000

20 1.1290 1.2290 1.2169 1.1169 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

21 1.1292 1.2284 1.2079 1.1087

20 1.1290 1.2290 1.2169 1.1169

14 1.0467 1.1965 1.2172 1.0674

20 1.1290 1.2290 1.2169 1.1169

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 170.416 339.118 2769.466 1391.730

2 680.004 59.463 485.616 5553.363

3 689.819 31.748 259.272 5633.521

4 232.126 147.843 1207.385 1895.700

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 283 of 352

5 340.453 155.334 1268.561 2780.362

6 2.020 16.340 133.444 16.496

7 5.345 15.103 123.343 43.654

8 7.996 15.081 123.160 65.300

9 39.747 1.549 12.648 324.603

10 58.976 1.657 13.532 481.637

11 160.520 319.427 2608.652 1310.914

12 17.715 78.981 645.015 144.676

13 18.136 212.745 1737.418 148.114

14 5.552 40.087 327.377 45.344

15 5.561 67.409 550.509 45.415

16 4.634 114.577 935.714 37.844

17 5.237 34.482 281.599 42.767

18 4.999 10.527 85.968 40.827

19 5.164 20.132 164.412 42.174

20 8.618 71.283 582.142 70.382

21 8.656 41.784 341.237 70.694

22 25.355 42.154 344.261 207.065

23 26.012 85.972 702.104 212.432

24 15.156 6.224 50.827 123.774

25 15.348 6.675 54.511 125.345

26 18.178 7.272 59.386 148.457

27 18.468 6.688 54.623 150.820

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 6


Governing Disturbing Force : 4.360 kip
Governing Restoring Force : 8.806 kip
Minimum Sliding Ratio for the Critical Load Case : 2.020
Critical Load Case for Overturning about X-Direction : 9
Governing Overturning Moment : 3.127 kip-ft
Governing Resisting Moment : 39.550 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 12.648

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 3.127 kip
Governing Restoring Force : 4.843 kip
Minimum Sliding Ratio for the Critical Load Case : 1.549
Critical Load Case for Overturning about Z-Direction : 6
Governing Overturning Moment : -4.360 kip-ft
Governing Resisting Moment : 71.914 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 16.496

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 284 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 62.782 kip, Load Case # 20

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 99.169 kip

Distance along X to design for shear,


Dx = 2.596 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 74.377 kip

Critical load case for Vux is # 20 21.779 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 285 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 99.169 kip

Distance along X to design for shear, Dz = 5.570 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 74.377 kip

Critical load case for Vuz is # 20 22.415 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 20

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 286 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 3.263 ft
a distance, Dx =

Ultimate moment, 46.075 kip-ft

Nominal moment capacity, Mn = 51.194 kip-ft

Required = 0.00166

Since OK

Area of Steel Required, As = 1.411 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 7.635 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.013 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 13

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.430 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00166

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 7.635 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 287 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 20

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 3.263 ft
a distance, Dz =

Ultimate moment, 44.671 kip-ft

Nominal moment capacity, Mn = 49.634 kip-ft

Required = 0.00177

Since OK

Area of Steel Required, As = 1.345 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.250 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 288 of 352

Available development length for bars, DL


3.013 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 7

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.400 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00179

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 15.250 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.263 ft
at a distance, Dx =

Ultimate moment, 6.522 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 289 of 352

Nominal moment capacity, Mn = 7.247 kip-ft

Required = 0.00025

Since OK

Area of Steel Required, As = 1.345 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.250 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.263 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 290 of 352

Ultimate moment, 6.522 kip-ft

Nominal moment capacity, Mn = 7.247 kip-ft

Required = 0.00023

Since OK

Area of Steel Required, As = 1.411 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.635 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 52

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 291 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 292 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 293 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 36.223 0.134 -0.080 0.000 0.000
2 4.589 0.003 0.204 0.000 0.000
3 0.915 -0.008 -0.245 0.000 0.000
4 4.571 0.016 -0.063 0.000 0.000
5 0.961 0.031 0.048 0.000 0.000
6 7.608 -4.360 0.539 0.000 0.000
7 -2.446 0.473 0.251 0.000 0.000
8 6.941 -1.585 -0.561 0.000 0.000
9 -0.318 -0.122 3.127 0.000 0.000
10 0.360 0.088 -3.127 0.000 0.000
11 50.713 0.188 -0.112 0.000 0.000
12 56.151 -1.964 0.576 0.000 0.000
13 56.049 -2.007 -0.321 0.000 0.000
14 61.190 -6.780 1.018 0.000 0.000
15 61.126 -6.807 0.457 0.000 0.000
16 53.683 -6.436 0.966 0.000 0.000
17 61.193 -8.082 0.317 0.000 0.000
18 55.385 -6.912 3.267 0.000 0.000
19 55.928 -6.744 -1.736 0.000 0.000
20 48.908 -1.229 0.826 0.000 0.000
21 48.844 -1.255 0.265 0.000 0.000
22 63.927 -4.521 -0.473 0.000 0.000
23 63.863 -4.547 -1.033 0.000 0.000
24 52.312 -2.180 5.428 0.000 0.000
25 52.248 -2.206 4.868 0.000 0.000
26 53.398 -1.844 -4.579 0.000 0.000
27 53.333 -1.871 -5.139 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 36.223 0.134 -0.080 0.000 0.000
2 4.589 0.003 0.204 0.000 0.000
3 0.915 -0.008 -0.245 0.000 0.000
4 4.571 0.016 -0.063 0.000 0.000
5 0.961 0.031 0.048 0.000 0.000
6 7.608 -4.360 0.539 0.000 0.000
7 -2.446 0.473 0.251 0.000 0.000
8 6.941 -1.585 -0.561 0.000 0.000
9 -0.318 -0.122 3.127 0.000 0.000
10 0.360 0.088 -3.127 0.000 0.000
11 50.713 0.188 -0.112 0.000 0.000
12 56.151 -1.964 0.576 0.000 0.000
13 56.049 -2.007 -0.321 0.000 0.000
14 61.190 -6.780 1.018 0.000 0.000
15 61.126 -6.807 0.457 0.000 0.000
16 53.683 -6.436 0.966 0.000 0.000
17 61.193 -8.082 0.317 0.000 0.000
18 55.385 -6.912 3.267 0.000 0.000
19 55.928 -6.744 -1.736 0.000 0.000
20 48.908 -1.229 0.826 0.000 0.000
21 48.844 -1.255 0.265 0.000 0.000
22 63.927 -4.521 -0.473 0.000 0.000
23 63.863 -4.547 -1.033 0.000 0.000
24 52.312 -2.180 5.428 0.000 0.000
25 52.248 -2.206 4.868 0.000 0.000
26 53.398 -1.844 -4.579 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 294 of 352

27 53.333 -1.871 -5.139 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 16.399 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 8.167 ft Governing Load Case : #9

Width (W2) = 8.167 ft Governing Load Case : #9

Depth (D2) = 1.000 ft Governing Load Case : #9

Area (A2) = 66.694 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

23 1.1690 1.0688 1.0461 1.1463 0.000

23 1.1690 1.0688 1.0461 1.1463 0.000

22 1.1635 1.0639 1.0535 1.1531 0.000

17 1.1530 0.9750 0.9820 1.1600 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

23 1.1690 1.0688 1.0461 1.1463

23 1.1690 1.0688 1.0461 1.1463

22 1.1635 1.0639 1.0535 1.1531

17 1.1530 0.9750 0.9820 1.1600

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 295 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 172.073 287.726 2349.761 1405.267

2 2311.242 35.817 292.504 18875.145

3 654.396 22.254 181.743 5344.235

4 462.923 115.294 941.565 3780.540

5 178.682 113.614 927.847 1459.234

6 2.020 16.340 133.444 16.496

7 7.996 15.081 123.160 65.300

8 5.345 15.103 123.343 43.654

9 39.747 1.549 12.648 324.603

10 58.976 1.657 13.532 481.637

11 161.434 269.935 2204.471 1318.376

12 16.838 57.405 468.809 137.509

13 16.457 103.015 841.291 134.402

14 5.250 34.973 285.616 42.875

15 5.225 77.767 635.101 42.670

16 4.948 32.953 269.119 40.406

17 4.405 112.271 916.881 35.970

18 4.730 10.006 81.720 38.631

19 4.888 18.989 155.074 39.921

20 23.975 35.662 291.242 195.798

21 23.445 110.840 905.194 191.465

22 8.177 78.228 638.866 66.777

23 8.122 35.752 291.977 66.331

24 14.294 5.740 46.878 116.738

25 14.109 6.395 52.223 115.220

26 17.190 6.923 56.540 140.381

27 16.929 6.162 50.323 138.257

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 6


Governing Disturbing Force : -4.360 kip
Governing Restoring Force : 8.806 kip
Minimum Sliding Ratio for the Critical Load Case : 2.020

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 296 of 352

Critical Load Case for Overturning about X-Direction : 9


Governing Overturning Moment : 3.127 kip-ft
Governing Resisting Moment : 39.550 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 12.648

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 9


Governing Disturbing Force : 3.127 kip
Governing Restoring Force : 4.843 kip
Minimum Sliding Ratio for the Critical Load Case : 1.549
Critical Load Case for Overturning about Z-Direction : 6
Governing Overturning Moment : 4.360 kip-ft
Governing Resisting Moment : 71.914 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 16.496

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 58.825 kip, Load Case # 22

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 297 of 352

From ACI Cl.11.3.1.1, Vc = 99.169 kip

Distance along X to design for shear,


Dx = 2.596 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 74.377 kip

Critical load case for Vux is # 23 20.469 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 99.169 kip

Distance along X to design for shear, Dz = 2.596 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 74.377 kip

Critical load case for Vuz is # 22 21.045 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 298 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 22

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 3.263 ft
a distance, Dx =

Ultimate moment, 43.263 kip-ft

Nominal moment capacity, Mn = 48.070 kip-ft

Required = 0.00155

Since OK

Area of Steel Required, As = 1.411 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 7.635 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 299 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.013 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 13

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.430 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00166

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 7.635 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 23

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 3.263 ft
a distance, Dz =

Ultimate moment, 41.996 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 300 of 352

Nominal moment capacity, Mn = 46.662 kip-ft

Required = 0.00166

Since OK

Area of Steel Required, As = 1.345 in2

Selected Bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.250 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.013 ft
=
Try bar size #4 Area of one bar = 0.200 in2

Number of bars required, Nbar = 7

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 1.400 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00179

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 15.250 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 301 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.263 ft
at a distance, Dx =

Ultimate moment, 6.522 kip-ft

Nominal moment capacity, Mn = 7.247 kip-ft

Required = 0.00025

Since OK

Area of Steel Required, As = 1.345 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.250 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 302 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.263 ft
at a distance, Dx =

Ultimate moment, 6.522 kip-ft

Nominal moment capacity, Mn = 7.247 kip-ft

Required = 0.00023

Since OK

Area of Steel Required, As = 1.411 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.635 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 53

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 303 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 304 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 305 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 73.165 -0.224 -0.182 0.000 0.000
2 6.303 -0.338 -0.300 0.000 0.000
3 4.162 0.219 0.178 0.000 0.000
4 6.105 0.068 0.030 0.000 0.000
5 4.085 -0.059 -0.038 0.000 0.000
6 11.712 0.322 -0.265 0.000 0.000
7 0.885 2.887 0.153 0.000 0.000
8 -0.095 -3.034 0.023 0.000 0.000
9 0.869 -0.001 3.206 0.000 0.000
10 -0.400 0.007 -3.168 0.000 0.000
11 102.431 -0.314 -0.255 0.000 0.000
12 110.274 -0.742 -0.892 0.000 0.000
13 110.082 0.350 -0.018 0.000 0.000
14 116.925 -0.150 -0.981 0.000 0.000
15 116.805 0.532 -0.435 0.000 0.000
16 107.246 2.555 -0.521 0.000 0.000
17 106.462 -2.181 -0.625 0.000 0.000
18 107.233 0.245 1.922 0.000 0.000
19 106.217 0.251 -3.178 0.000 0.000
20 105.459 4.114 -0.444 0.000 0.000
21 105.338 4.797 0.102 0.000 0.000
22 103.890 -5.359 -0.653 0.000 0.000
23 103.770 -4.676 -0.107 0.000 0.000
24 105.432 -0.507 4.441 0.000 0.000
25 105.311 0.176 4.987 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 306 of 352

26 103.401 -0.494 -5.758 0.000 0.000


27 103.281 0.189 -5.212 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 73.165 -0.224 -0.182 0.000 0.000
2 6.303 -0.338 -0.300 0.000 0.000
3 4.162 0.219 0.178 0.000 0.000
4 6.105 0.068 0.030 0.000 0.000
5 4.085 -0.059 -0.038 0.000 0.000
6 11.712 0.322 -0.265 0.000 0.000
7 0.885 2.887 0.153 0.000 0.000
8 -0.095 -3.034 0.023 0.000 0.000
9 0.869 -0.001 3.206 0.000 0.000
10 -0.400 0.007 -3.168 0.000 0.000
11 102.431 -0.314 -0.255 0.000 0.000
12 110.274 -0.742 -0.892 0.000 0.000
13 110.082 0.350 -0.018 0.000 0.000
14 116.925 -0.150 -0.981 0.000 0.000
15 116.805 0.532 -0.435 0.000 0.000
16 107.246 2.555 -0.521 0.000 0.000
17 106.462 -2.181 -0.625 0.000 0.000
18 107.233 0.245 1.922 0.000 0.000
19 106.217 0.251 -3.178 0.000 0.000
20 105.459 4.114 -0.444 0.000 0.000
21 105.338 4.797 0.102 0.000 0.000
22 103.890 -5.359 -0.653 0.000 0.000
23 103.770 -4.676 -0.107 0.000 0.000
24 105.432 -0.507 4.441 0.000 0.000
25 105.311 0.176 4.987 0.000 0.000
26 103.401 -0.494 -5.758 0.000 0.000
27 103.281 0.189 -5.212 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 29.650 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 8.167 ft Governing Load Case : # 10

Width (W2) = 8.167 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 66.694 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 307 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

14 1.9156 1.9123 1.8907 1.8940 0.000

14 1.9156 1.9123 1.8907 1.8940 0.000

15 1.9003 1.9120 1.9024 1.8907 0.000

14 1.9156 1.9123 1.8907 1.8940 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

14 1.9156 1.9123 1.8907 1.8940

14 1.9156 1.9123 1.8907 1.8940

15 1.9003 1.9120 1.9024 1.8907

14 1.9156 1.9123 1.8907 1.8940

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 185.366 228.162 1863.319 1513.821

2 24.145 27.189 222.043 197.180

3 32.367 39.759 324.702 264.333

4 119.265 266.155 2173.603 974.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 308 of 352

5 119.994 186.923 1526.535 979.948

6 33.724 40.916 334.144 275.414

7 1.886 35.609 290.806 15.404

8 1.633 219.377 1791.580 13.337

9 4013.041 1.696 13.848 32773.170

10 702.376 1.516 12.377 5736.068

11 178.995 220.320 1799.281 1461.795

12 81.001 67.458 550.907 661.505

13 171.559 3347.760 27340.037 1401.068

14 421.849 64.701 528.394 3445.101

15 119.108 145.789 1190.610 972.714

16 22.943 112.525 918.951 187.371

17 26.699 93.135 760.601 218.042

18 239.386 30.505 249.121 1954.985

19 231.127 18.285 149.328 1887.541

20 14.033 129.932 1061.115 114.605

21 12.023 567.270 4632.709 98.189

22 10.627 87.231 712.386 86.787

23 12.166 532.405 4347.971 99.355

24 113.891 12.997 106.141 930.109

25 327.618 11.562 94.422 2675.550

26 114.858 9.847 80.417 938.006

27 299.542 10.867 88.746 2446.259

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -3.034 kip
Governing Restoring Force : 4.955 kip
Minimum Sliding Ratio for the Critical Load Case : 1.633
Critical Load Case for Overturning about X-Direction : 10
Governing Overturning Moment : -3.168 kip-ft
Governing Resisting Moment : 39.216 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 12.377

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -3.168 kip
Governing Restoring Force : 4.802 kip
Minimum Sliding Ratio for the Critical Load Case : 1.516
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 3.034 kip-ft
Governing Resisting Moment : 40.463 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 13.337

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 309 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 107.594 kip, Load Case # 14

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 99.169 kip

Distance along X to design for shear,


Dx = 2.596 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 74.377 kip

Critical load case for Vux is # 14 37.331 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 310 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 99.169 kip

Distance along X to design for shear, Dz = 5.570 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 74.377 kip

Critical load case for Vuz is # 15 37.221 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 15

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 311 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 3.263 ft
a distance, Dx =

Ultimate moment, 76.334 kip-ft

Nominal moment capacity, Mn = 84.816 kip-ft

Required = 0.00277

Since OK

Area of Steel Required, As = 2.174 in2

Selected bar Size = #6


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 18.000 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#6 @ 18.000 in o.c.

Required development length for bars = =1.391 ft

Available development length for bars, DL


3.013 ft
=
Try bar size #6 Area of one bar = 0.440 in2

Number of bars required, Nbar = 5

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.200 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.719 ft
=

Reinforcement ratio, = 0.00260

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 18.000 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 312 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 14

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 3.263 ft
a distance, Dz =

Ultimate moment, 76.570 kip-ft

Nominal moment capacity, Mn = 85.078 kip-ft

Required = 0.00341

Since OK

Area of Steel Required, As = 2.420 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 4.363 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 4.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 313 of 352

Available development length for bars, DL


3.013 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 22

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.420 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.635 ft
=

Reinforcement ratio, = 0.00324

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 4.363 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.263 ft
at a distance, Dx =

Ultimate moment, 6.522 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 314 of 352

Nominal moment capacity, Mn = 7.247 kip-ft

Required = 0.00025

Since OK

Area of Steel Required, As = 1.345 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.250 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.263 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 315 of 352

Ultimate moment, 6.522 kip-ft

Nominal moment capacity, Mn = 7.247 kip-ft

Required = 0.00023

Since OK

Area of Steel Required, As = 1.411 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.635 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 54

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 316 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 317 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 318 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 70.586 0.228 -0.137 0.000 0.000
2 4.835 -0.223 -0.240 0.000 0.000
3 4.983 0.343 0.142 0.000 0.000
4 4.808 0.064 0.027 0.000 0.000
5 5.020 -0.072 -0.034 0.000 0.000
6 11.712 -0.322 -0.265 0.000 0.000
7 -0.095 3.034 0.023 0.000 0.000
8 0.885 -2.887 0.153 0.000 0.000
9 0.869 0.001 3.206 0.000 0.000
10 -0.400 -0.007 -3.168 0.000 0.000
11 98.820 0.319 -0.192 0.000 0.000
12 106.326 -0.360 -0.736 0.000 0.000
13 106.225 0.764 -0.028 0.000 0.000
14 113.297 -0.537 -0.863 0.000 0.000
15 113.234 0.165 -0.421 0.000 0.000
16 103.367 2.185 -0.571 0.000 0.000
17 104.151 -2.551 -0.467 0.000 0.000
18 104.138 -0.241 1.976 0.000 0.000
19 103.122 -0.247 -3.124 0.000 0.000
20 100.262 4.671 -0.535 0.000 0.000
21 100.199 5.374 -0.093 0.000 0.000
22 101.830 -4.801 -0.327 0.000 0.000
23 101.767 -4.099 0.116 0.000 0.000
24 101.803 -0.181 4.559 0.000 0.000
25 101.741 0.522 5.001 0.000 0.000
26 99.773 -0.194 -5.641 0.000 0.000
27 99.710 0.509 -5.199 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 70.586 0.228 -0.137 0.000 0.000
2 4.835 -0.223 -0.240 0.000 0.000
3 4.983 0.343 0.142 0.000 0.000
4 4.808 0.064 0.027 0.000 0.000
5 5.020 -0.072 -0.034 0.000 0.000
6 11.712 -0.322 -0.265 0.000 0.000
7 -0.095 3.034 0.023 0.000 0.000
8 0.885 -2.887 0.153 0.000 0.000
9 0.869 0.001 3.206 0.000 0.000
10 -0.400 -0.007 -3.168 0.000 0.000
11 98.820 0.319 -0.192 0.000 0.000
12 106.326 -0.360 -0.736 0.000 0.000
13 106.225 0.764 -0.028 0.000 0.000
14 113.297 -0.537 -0.863 0.000 0.000
15 113.234 0.165 -0.421 0.000 0.000
16 103.367 2.185 -0.571 0.000 0.000
17 104.151 -2.551 -0.467 0.000 0.000
18 104.138 -0.241 1.976 0.000 0.000
19 103.122 -0.247 -3.124 0.000 0.000
20 100.262 4.671 -0.535 0.000 0.000
21 100.199 5.374 -0.093 0.000 0.000
22 101.830 -4.801 -0.327 0.000 0.000
23 101.767 -4.099 0.116 0.000 0.000
24 101.803 -0.181 4.559 0.000 0.000
25 101.741 0.522 5.001 0.000 0.000
26 99.773 -0.194 -5.641 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 319 of 352

27 99.710 0.509 -5.199 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 28.743 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 8.167 ft Governing Load Case : # 10

Width (W2) = 8.167 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 66.694 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

14 1.8642 1.8523 1.8333 1.8452 0.000

15 1.8506 1.8543 1.8450 1.8413 0.000

15 1.8506 1.8543 1.8450 1.8413 0.000

14 1.8642 1.8523 1.8333 1.8452 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

14 1.8642 1.8523 1.8333 1.8452

15 1.8506 1.8543 1.8450 1.8413

15 1.8506 1.8543 1.8450 1.8413

14 1.8642 1.8523 1.8333 1.8452

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 320 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 176.952 293.694 2398.498 1445.106

2 33.271 30.929 252.587 271.713

3 21.861 52.940 432.345 178.531

4 114.953 277.518 2266.400 938.781

5 104.316 220.036 1796.965 851.911

6 33.724 40.916 334.144 275.414

7 1.633 219.377 1791.580 13.337

8 1.886 35.609 290.806 15.404

9 4013.041 1.696 13.848 32773.170

10 702.376 1.516 12.377 5736.068

11 170.676 283.277 2313.430 1393.852

12 161.684 79.053 645.600 1320.420

13 76.084 2064.426 16859.479 621.351

14 114.825 71.415 583.219 937.737

15 372.722 146.359 1195.263 3043.894

16 25.941 99.242 810.476 211.853

17 22.373 122.241 998.299 182.715

18 236.992 28.887 235.907 1935.432

19 228.661 18.106 147.867 1867.399

20 11.802 103.010 841.246 96.386

21 10.254 592.762 4840.892 83.742

22 11.646 171.154 1397.755 95.112

23 13.634 483.625 3949.605 111.344

24 309.595 12.264 100.152 2528.360

25 107.105 11.173 91.244 874.688

26 283.403 9.731 79.467 2314.454

27 107.869 10.552 86.178 880.926

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 3.034 kip
Governing Restoring Force : 4.955 kip
Minimum Sliding Ratio for the Critical Load Case : 1.633

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 321 of 352

Critical Load Case for Overturning about X-Direction : 10


Governing Overturning Moment : -3.168 kip-ft
Governing Resisting Moment : 39.216 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 12.377

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -3.168 kip
Governing Restoring Force : 4.802 kip
Minimum Sliding Ratio for the Critical Load Case : 1.516
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -3.034 kip-ft
Governing Resisting Moment : 40.463 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 13.337

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 104.255 kip, Load Case # 14

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 322 of 352

From ACI Cl.11.3.1.1, Vc = 99.169 kip

Distance along X to design for shear,


Dx = 2.596 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 74.377 kip

Critical load case for Vux is # 14 36.158 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 99.169 kip

Distance along X to design for shear, Dz = 2.596 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 74.377 kip

Critical load case for Vuz is # 14 36.106 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 323 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 14

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 3.263 ft
a distance, Dx =

Ultimate moment, 74.049 kip-ft

Nominal moment capacity, Mn = 82.276 kip-ft

Required = 0.00269

Since OK

Area of Steel Required, As = 2.107 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 15.229 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 15.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 324 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.013 ft
=
Try bar size #5 Area of one bar = 0.310 in2

Number of bars required, Nbar = 7

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.170 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.724 ft
=

Reinforcement ratio, = 0.00255

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 15.229 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 14

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 3.263 ft
a distance, Dz =

Ultimate moment, 74.163 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 325 of 352

Nominal moment capacity, Mn = 82.404 kip-ft

Required = 0.00318

Since OK

Area of Steel Required, As = 2.299 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 4.581 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 4.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.013 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 21

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.310 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.645 ft
=

Reinforcement ratio, = 0.00305

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 4.581 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 326 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.263 ft
at a distance, Dx =

Ultimate moment, 6.522 kip-ft

Nominal moment capacity, Mn = 7.247 kip-ft

Required = 0.00025

Since OK

Area of Steel Required, As = 1.345 in2

Selected bar Size = #4


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 15.250 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#4 @ 15 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 327 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.263 ft
at a distance, Dx =

Ultimate moment, 6.522 kip-ft

Nominal moment capacity, Mn = 7.247 kip-ft

Required = 0.00023

Since OK

Area of Steel Required, As = 1.411 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.635 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 55

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 328 of 352

Input Values

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 329 of 352

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 330 of 352

22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL


23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 65.384 -0.003 -3.543 0.000 0.000
2 12.847 0.182 -3.164 0.000 0.000
3 2.264 -0.276 -0.068 0.000 0.000
4 12.159 -0.029 0.575 0.000 0.000
5 2.318 0.056 -0.017 0.000 0.000
6 -0.585 0.073 -0.111 0.000 0.000
7 -0.487 2.887 0.074 0.000 0.000
8 0.695 -2.928 0.049 0.000 0.000
9 4.438 -0.647 2.521 0.000 0.000
10 -3.702 0.535 -2.582 0.000 0.000
11 91.538 -0.005 -4.961 0.000 0.000
12 102.431 0.413 -9.397 0.000 0.000
13 101.245 -0.455 -3.497 0.000 0.000
14 92.689 0.350 -7.611 0.000 0.000
15 91.948 -0.192 -3.923 0.000 0.000
16 77.135 2.422 -4.371 0.000 0.000
17 78.081 -2.230 -4.391 0.000 0.000
18 81.075 -0.405 -2.413 0.000 0.000
19 74.563 0.540 -6.496 0.000 0.000
20 92.554 4.889 -7.370 0.000 0.000
21 91.812 4.347 -3.683 0.000 0.000
22 94.445 -4.415 -7.410 0.000 0.000
23 93.704 -4.958 -3.723 0.000 0.000
24 100.434 -0.764 -3.454 0.000 0.000
25 99.692 -1.307 0.233 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 331 of 352

26 87.410 1.126 -11.620 0.000 0.000


27 86.669 0.583 -7.933 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 65.384 -0.003 -3.543 0.000 0.000
2 12.847 0.182 -3.164 0.000 0.000
3 2.264 -0.276 -0.068 0.000 0.000
4 12.159 -0.029 0.575 0.000 0.000
5 2.318 0.056 -0.017 0.000 0.000
6 -0.585 0.073 -0.111 0.000 0.000
7 -0.487 2.887 0.074 0.000 0.000
8 0.695 -2.928 0.049 0.000 0.000
9 4.438 -0.647 2.521 0.000 0.000
10 -3.702 0.535 -2.582 0.000 0.000
11 91.538 -0.005 -4.961 0.000 0.000
12 102.431 0.413 -9.397 0.000 0.000
13 101.245 -0.455 -3.497 0.000 0.000
14 92.689 0.350 -7.611 0.000 0.000
15 91.948 -0.192 -3.923 0.000 0.000
16 77.135 2.422 -4.371 0.000 0.000
17 78.081 -2.230 -4.391 0.000 0.000
18 81.075 -0.405 -2.413 0.000 0.000
19 74.563 0.540 -6.496 0.000 0.000
20 92.554 4.889 -7.370 0.000 0.000
21 91.812 4.347 -3.683 0.000 0.000
22 94.445 -4.415 -7.410 0.000 0.000
23 93.704 -4.958 -3.723 0.000 0.000
24 100.434 -0.764 -3.454 0.000 0.000
25 99.692 -1.307 0.233 0.000 0.000
26 87.410 1.126 -11.620 0.000 0.000
27 86.669 0.583 -7.933 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 26.026 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 8.833 ft Governing Load Case : # 10

Width (W2) = 8.833 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 78.028 ft2

Pressures at Four Corners

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 332 of 352

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

12 1.5410 1.5482 1.3845 1.3774 0.000

12 1.5410 1.5482 1.3845 1.3774 0.000

25 1.4370 1.4142 1.4183 1.4411 0.000

25 1.4370 1.4142 1.4183 1.4411 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

12 1.5410 1.5482 1.3845 1.3774

12 1.5410 1.5482 1.3845 1.3774

25 1.4370 1.4142 1.4183 1.4411

25 1.4370 1.4142 1.4183 1.4411

Check for stability against overturning and sliding

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 11643.648 10.878 96.090 102852.222

2 67.487 3.879 34.268 596.133

3 25.285 101.978 900.804 223.351

4 418.132 20.746 183.258 3693.496

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 333 of 352

5 125.414 421.365 3722.059 1107.825

6 76.345 50.014 441.793 674.378

7 1.943 75.914 670.577 17.161

8 2.117 126.987 1121.717 18.702

9 12.484 3.201 28.276 110.277

10 7.484 1.549 13.686 66.112

11 11138.554 10.406 91.922 98390.556

12 138.208 6.073 53.645 1220.838

13 124.075 16.150 142.657 1095.995

14 148.989 6.858 60.582 1316.072

15 269.632 13.210 116.690 2381.751

16 18.339 10.163 89.774 161.998

17 20.130 10.224 90.316 177.819

18 114.635 19.228 169.849 1012.611

19 79.842 6.640 58.656 705.270

20 10.662 7.073 62.478 94.179

21 11.907 14.055 124.148 105.180

22 12.021 7.162 63.267 106.189

23 10.631 14.157 125.055 93.907

24 73.370 16.233 143.390 648.102

25 42.624 238.552 2107.210 376.510

26 44.026 4.265 37.671 388.898

27 84.356 6.200 54.770 745.142

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 7


Governing Disturbing Force : 2.887 kip
Governing Restoring Force : 5.609 kip
Minimum Sliding Ratio for the Critical Load Case : 1.943
Critical Load Case for Overturning about X-Direction : 10
Governing Overturning Moment : -2.582 kip-ft
Governing Resisting Moment : 35.345 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 13.686

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -2.582 kip
Governing Restoring Force : 4.001 kip
Minimum Sliding Ratio for the Critical Load Case : 1.549
Critical Load Case for Overturning about Z-Direction : 7
Governing Overturning Moment : -2.887 kip-ft
Governing Resisting Moment : 49.543 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 17.161

Shear Calculation

Punching Shear Check

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 334 of 352

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 95.444 kip, Load Case # 12

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

From ACI Cl.11.3.1.1, Vc = 107.264 kip

Distance along X to design for shear,


Dx = 2.930 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 80.448 kip

Critical load case for Vux is # 12 35.389 kip

0.75 X Vc > Vux hence, OK

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 335 of 352

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 107.264 kip

Distance along X to design for shear, Dz = 5.904 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 80.448 kip

Critical load case for Vuz is # 12 34.036 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 12

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 336 of 352

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 3.596 ft
a distance, Dx =

Ultimate moment, 75.144 kip-ft

Nominal moment capacity, Mn = 83.493 kip-ft

Required = 0.00252

Since OK

Area of Steel Required, As = 2.135 in2

Selected bar Size = #5


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 16.563 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 16.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.346 ft
=
Try bar size #5 Area of one bar = 0.310 in2

Number of bars required, Nbar = 7

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.170 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.724 ft
=

Reinforcement ratio, = 0.00236

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 16.563 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 337 of 352

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 12

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 3.596 ft
a distance, Dz =

Ultimate moment, 78.398 kip-ft

Nominal moment capacity, Mn = 87.109 kip-ft

Required = 0.00311

Since OK

Area of Steel Required, As = 2.429 in2

Selected Bar Size = #5


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 14.196 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#5 @ 14.000 in o.c.

Required development length for bars = =1.000 ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 338 of 352

Available development length for bars, DL


3.346 ft
=
Try bar size #5 Area of one bar = 0.310 in2

Number of bars required, Nbar = 8

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.480 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.645 ft
=

Reinforcement ratio, = 0.00302

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 14.196 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.596 ft
at a distance, Dx =

Ultimate moment, 8.569 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 339 of 352

Nominal moment capacity, Mn = 9.521 kip-ft

Required = 0.00031

Since OK

Area of Steel Required, As = 1.455 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.663 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Design For Top Reinforcement Parallel to X Axis

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.596 ft
at a distance, Dx =

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 340 of 352

Ultimate moment, 8.569 kip-ft

Nominal moment capacity, Mn = 9.521 kip-ft

Required = 0.00028

Since OK

Area of Steel Required, As = 1.526 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.663 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Isolated Footing 56

Input Values

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 341 of 352

Footing Geomtery

Design Type : Calculate Dimension


Footing Thickness (Ft) : 12.000 in
Footing Length - X (Fl) : 40.000 in
Footing Width - Z (Fw) : 40.000 in
Eccentricity along X (Oxd) : 0.000 in
Eccentricity along Z (Ozd) : 0.000 in

Column Dimensions

Column Shape : Rectangular


Column Length - X (Pl) : 1.640 ft
Column Width - Z (Pw) : 1.640 ft

Pedestal

Include Pedestal? No
Pedestal Shape : N/A
Pedestal Height (Ph) : N/A
Pedestal Length - X (Pl) : N/A
Pedestal Width - Z (Pw) : N/A

Design Parameters

Concrete and Rebar Properties

Unit Weight of Concrete : 150.000 lb/ft3


Strength of Concrete : 4.000 ksi
Yield Strength of Steel : 60.000 ksi
Minimum Bar Size : #3
Maximum Bar Size : #10
Minimum Bar Spacing : 2.000 in
Maximum Bar Spacing : 18.000 in
Pedestal Clear Cover (P, CL) : 3.000 in
Footing Clear Cover (F, CL) : 3.000 in

Soil Properties

Soil Type : UnDrained


Unit Weight : 112.000 lb/ft3
Soil Bearing Capacity : 4.000 kip/ft2
Soil Surcharge : 0.000 kip/in2
Depth of Soil above Footing : 0.000 in
Undrained Shear Strength : 0.000 kip/in2

Sliding and Overturning

Coefficient of Friction : 0.500


Factor of Safety Against Sliding : 1.500
Factor of Safety Against Overturning : 1.500

------------------------------------------------------

Design Calculations

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 342 of 352

Footing Size

Initial Length (Lo) = 3.333 ft

Initial Width (Wo) = 3.333 ft

Load Combination/s- Service Stress Level


Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL
26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL
27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL
Load Combination/s- Strength Level
Load Combination
Load Combination Title
Number
1 DL
2 LL 1
3 LL 2
4 LL 3
5 LL 4
6 RLL
7 WL +X
8 WL -X
9 WL +Z
10 WL -Z
11 1.4 DL
12 1.2 DL + 1.6 LL 1 4 + 0.5 RLL
13 1.2 DL + 1.6 LL 2 3 + 0.5 RLL
14 1.2 DL + 1.6 RLL + 1.0 LL 1 4
15 1.2 DL + 1.6 RLL + 1.0 LL 2 3
16 1.2 DL + 1.6 RLL + 0.8 WL +X
17 1.2 DL + 1.6 RLL + 0.8 WL -X
18 1.2 DL + 1.6 RLL + 0.8 WL +Z
19 1.2 DL + 1.6 RLL + 0.8 WL -Z
20 1.2 DL + 1.6 WL+X + 1.0 LL 14 + 0.5 RLL
21 1.2 DL + 1.6 WL+X + 1.0 LL 2 3 + 0.5 RLL
22 1.2 DL + 1.6 WL-X + 1.0 LL 14 + 0.5 RLL
23 1.2 DL + 1.6 WL-X + 1.0 LL 2 3 + 0.5 RLL
24 1.2 DL + 1.6 WL+Z + 1.0 LL 14 + 0.5 RLL
25 1.2 DL + 1.6 WL+Z + 1.0 LL 2 3 + 0.5 RLL

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 343 of 352

26 1.2 DL + 1.6 WL-Z + 1.0 LL 14 + 0.5 RLL


27 1.2 DL + 1.6 WL-Z + 1.0 LL 2 3 + 0.5 RLL

Applied Loads - Service Stress Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 61.516 0.009 -2.971 0.000 0.000
2 2.988 0.419 0.015 0.000 0.000
3 11.466 -0.323 -3.006 0.000 0.000
4 3.052 -0.073 -0.005 0.000 0.000
5 11.423 0.047 0.563 0.000 0.000
6 -0.585 -0.073 -0.111 0.000 0.000
7 0.695 2.928 0.049 0.000 0.000
8 -0.487 -2.887 0.074 0.000 0.000
9 4.438 0.647 2.521 0.000 0.000
10 -3.702 -0.535 -2.582 0.000 0.000
11 86.122 0.013 -4.160 0.000 0.000
12 96.585 0.720 -2.696 0.000 0.000
13 96.755 -0.658 -8.439 0.000 0.000
14 87.294 0.360 -3.165 0.000 0.000
15 87.401 -0.501 -6.755 0.000 0.000
16 73.439 2.237 -3.704 0.000 0.000
17 72.494 -2.415 -3.684 0.000 0.000
18 76.434 0.412 -1.726 0.000 0.000
19 69.922 -0.533 -5.809 0.000 0.000
20 89.050 5.126 -2.965 0.000 0.000
21 89.157 4.264 -6.554 0.000 0.000
22 87.159 -4.179 -2.925 0.000 0.000
23 87.266 -5.040 -6.514 0.000 0.000
24 95.039 1.475 0.991 0.000 0.000
25 95.146 0.613 -2.598 0.000 0.000
26 82.015 -0.415 -7.175 0.000 0.000
27 82.122 -1.276 -10.764 0.000 0.000

Applied Loads - Strength Level


Axial Shear X Shear Z Moment X Moment Z
LC
(kip) (kip) (kip) (kip-ft) (kip-ft)
1 61.516 0.009 -2.971 0.000 0.000
2 2.988 0.419 0.015 0.000 0.000
3 11.466 -0.323 -3.006 0.000 0.000
4 3.052 -0.073 -0.005 0.000 0.000
5 11.423 0.047 0.563 0.000 0.000
6 -0.585 -0.073 -0.111 0.000 0.000
7 0.695 2.928 0.049 0.000 0.000
8 -0.487 -2.887 0.074 0.000 0.000
9 4.438 0.647 2.521 0.000 0.000
10 -3.702 -0.535 -2.582 0.000 0.000
11 86.122 0.013 -4.160 0.000 0.000
12 96.585 0.720 -2.696 0.000 0.000
13 96.755 -0.658 -8.439 0.000 0.000
14 87.294 0.360 -3.165 0.000 0.000
15 87.401 -0.501 -6.755 0.000 0.000
16 73.439 2.237 -3.704 0.000 0.000
17 72.494 -2.415 -3.684 0.000 0.000
18 76.434 0.412 -1.726 0.000 0.000
19 69.922 -0.533 -5.809 0.000 0.000
20 89.050 5.126 -2.965 0.000 0.000
21 89.157 4.264 -6.554 0.000 0.000
22 87.159 -4.179 -2.925 0.000 0.000
23 87.266 -5.040 -6.514 0.000 0.000
24 95.039 1.475 0.991 0.000 0.000
25 95.146 0.613 -2.598 0.000 0.000
26 82.015 -0.415 -7.175 0.000 0.000

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 344 of 352

27 82.122 -1.276 -10.764 0.000 0.000

Reduction of force due to buoyancy = 0.000 kip


Effect due to adhesion = 0.000 kip
Area from initial length and width, Ao = L X W = 11.111 ft2
o o
Min. area required from bearing pressure, Amin = P / q
max
= 24.607 ft2

Note: Amin is an initial estimation.


P = Critical Factored Axial Load(without self weight/buoyancy/soil).
qmax = Respective Factored Bearing Capacity.

Final Footing Size

Length (L2) = 8.833 ft Governing Load Case : # 10

Width (W2) = 8.833 ft Governing Load Case : # 10

Depth (D2) = 1.000 ft Governing Load Case : # 10

Area (A2) = 78.028 ft 2

Pressures at Four Corners

Pressure at Pressure at Pressure at Pressure at Area of footing


corner 1 corner 2 corner 3 corner 4 in uplift (Au)
Load Case (q1) (q2) (q3) (q4)
(kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2) (ft2)

13 1.4692 1.4577 1.3108 1.3223 0.000

13 1.4692 1.4577 1.3108 1.3223 0.000

24 1.3466 1.3722 1.3895 1.3638 0.000

24 1.3466 1.3722 1.3895 1.3638 0.000

If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero
and the pressure will be redistributed to remaining corners.

Summary of Adjusted Pressures at 4 corners Four Corners

Pressure at Pressure at Pressure at Pressure at


corner 1 (q1) corner 2 (q2) corner 3 (q3) corner 4 (q4)

Load Case (kip/ft2) (kip/ft2) (kip/ft2) (kip/ft2)

13 1.4692 1.4577 1.3108 1.3223

13 1.4692 1.4577 1.3108 1.3223

24 1.3466 1.3722 1.3895 1.3638

24 1.3466 1.3722 1.3895 1.3638

Check for stability against overturning and sliding

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 345 of 352

Factor of safety against Factor of safety against


-
sliding overturning

Load Case Along X- Along Z- About X- About Z-


No. Direction Direction Direction Direction

1 3928.063 12.322 108.842 34697.892

2 17.536 500.080 4417.370 154.900

3 35.866 3.853 34.039 316.814

4 101.389 1517.677 13406.151 895.604

5 247.608 20.527 181.319 2187.208

6 76.345 50.014 441.793 674.378

7 2.117 126.987 1121.717 18.702

8 1.943 75.914 670.577 17.161

9 12.484 3.201 28.276 110.277

10 7.484 1.549 13.686 66.111

11 3748.677 11.759 103.871 33113.315

12 75.225 20.082 177.394 664.488

13 82.357 6.426 56.764 727.484

14 137.387 15.638 138.140 1213.587

15 98.886 7.336 64.803 873.489

16 19.028 11.493 101.520 168.082

17 17.433 11.427 100.938 153.992

18 106.993 25.531 225.525 945.107

19 76.568 7.026 62.059 676.351

20 9.828 16.992 150.092 86.818

21 11.826 7.694 67.968 104.466

22 11.829 16.901 149.294 104.493

23 9.818 7.597 67.104 86.727

24 36.189 53.834 475.533 319.665

25 87.093 20.565 181.656 769.321

26 112.915 6.531 57.691 997.412

27 36.754 4.358 38.498 324.662

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - X Direction

Critical Load Case for Sliding along X-Direction : 8


Governing Disturbing Force : -2.887 kip
Governing Restoring Force : 5.609 kip
Minimum Sliding Ratio for the Critical Load Case : 1.943

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 346 of 352

Critical Load Case for Overturning about X-Direction : 10


Governing Overturning Moment : -2.582 kip-ft
Governing Resisting Moment : 35.345 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 13.686

Critical Load Case And The Governing Factor Of Safety For Overturning And Sliding - Z Direction

Critical Load Case for Sliding along Z-Direction : 10


Governing Disturbing Force : -2.582 kip
Governing Restoring Force : 4.001 kip
Minimum Sliding Ratio for the Critical Load Case : 1.549
Critical Load Case for Overturning about Z-Direction : 8
Governing Overturning Moment : 2.887 kip-ft
Governing Resisting Moment : 49.543 kip-ft
Minimum Overturning Ratio for the Critical Load Case : 17.161

Shear Calculation

Punching Shear Check

Total Footing Depth, D = 1.000ft


Calculated Effective Depth, deff = D - Ccover - 1.0 = 0.667 ft 1 inch is deducted from total depth to cater bar dia(US Convention).

For rectangular column, = Bcol / Dcol = 1.000

Effective depth, deff, increased until 0.75XVc Punching Shear Force

Punching Shear Force, Vu = 90.155 kip, Load Case # 13

From ACI Cl.11.12.2.1, bo for column= 9.228 ft

Equation 11-33, Vc1 = 336.183 kip

Equation 11-34, Vc2 = 273.970 kip

Equation 11-35, Vc3 = 224.122 kip

Punching shear strength, Vc = 0.75 X minimum of (Vc1, Vc2, Vc3) = 168.092 kip

0.75 X Vc > Vu hence, OK

Along X Direction

(Shear Plane Parallel to Global X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 347 of 352

From ACI Cl.11.3.1.1, Vc = 107.264 kip

Distance along X to design for shear,


Dx = 2.930 ft

Check that 0.75 X Vc > Vux where Vux is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the X axis.

From above calculations, 0.75 X Vc = 80.448 kip

Critical load case for Vux is # 13 33.362 kip

0.75 X Vc > Vux hence, OK

One-Way Shear Check

Along Z Direction

(Shear Plane Parallel to Global Z Axis)

From ACI Cl.11.3.1.1, Vc = 107.264 kip

Distance along X to design for shear, Dz = 2.930 ft

Check that 0.75 X Vc > Vuz where Vuz is the shear force for the critical load cases at a distance deff from the face of the column caused by bending
about the Z axis.

From above calculations, 0.75 X Vc = 80.448 kip

Critical load case for Vuz is # 13 32.190 kip

0.75 X Vc > Vuz hence, OK

Design for Flexure about Z Axis

(For Reinforcement Parallel to X Axis)

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 348 of 352

Calculate the flexural reinforcement along the X direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 13

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about Z axis is


performed at the face of the column at 3.596 ft
a distance, Dx =

Ultimate moment, 71.077 kip-ft

Nominal moment capacity, Mn = 78.974 kip-ft

Required = 0.00238

Since OK

Area of Steel Required, As = 2.017 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = = 2.000 in

Selected spacing (S) = 5.535 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 5.000 in o.c.

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 349 of 352

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.346 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 19

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.090 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.734 ft
=

Reinforcement ratio, = 0.00224

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, 5.535 in
distance between bars, Cd = Min. User Spacing) =

Check to see if width is sufficient to accomodate bars

Design for Flexure about X axis

(For Reinforcement Parallel to Z Axis)

Calculate the flexural reinforcement along the Z direction of the footing. Find the area of steel required, A, as per Section 3.8 of Reinforced Concrete
Design (5th ed.) by Salmon and Wang (Ref. 1)

Critical Load Case # 13

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about X axis is


performed at the face of the column at 3.596 ft
a distance, Dz =

Ultimate moment, 73.895 kip-ft

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 350 of 352

Nominal moment capacity, Mn = 82.106 kip-ft

Required = 0.00273

Since OK

Area of Steel Required, As = 2.207 in2

Selected Bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 4.981 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

Safe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 4.000 in o.c.

Required development length for bars = =1.000 ft

Available development length for bars, DL


3.346 ft
=
Try bar size #3 Area of one bar = 0.110 in2

Number of bars required, Nbar = 21

Because the number of bars is rounded up, make sure new reinforcement ratio < ρmax

Total reinforcement area, As_total = Nbar X (Area of one bar) = 2.310 in2
deff = D - Ccover - 0.5 X (dia. of one bar) 0.666 ft
=

Reinforcement ratio, = 0.00273

From ACI Cl.7.6.1, minimum req'd clear max (Diameter of one bar, 1.0, Min. 4.981 in
distance between bars, Cd = User Spacing) =

Check to see if width is sufficient to accomodate bars

Bending moment for uplift cases will be calculated based solely on selfweight, soil depth and surcharge loading.

As the footing size has already been determined based on all servicebility load cases, and design moment calculation is based on selfweight, soil depth
and surcharge only, top reinforcement value for all pure uplift load cases will be the same.

Design For Top Reinforcement Parallel to Z Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 351 of 352

Calculate the flexural reinforcement for Mx. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl. 7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.596 ft
at a distance, Dx =

Ultimate moment, 8.569 kip-ft

Nominal moment capacity, Mn = 9.521 kip-ft

Required = 0.00031

Since OK

Area of Steel Required, As = 1.455 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.663 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Design For Top Reinforcement Parallel to X Axis

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
Isolated Footing Design Page 352 of 352

First load case to be in pure uplift #

Calculate the flexural reinforcement for Mz. Find the area of steel required

The strength values of steel and concrete used in the formulae are in ksi

Factor from ACI Cl.10.2.7.3 = 0.850

From ACI Cl. 10.3.2, = 0.02851

From ACI Cl. 10.3.3, = 0.02138

From ACI Cl.7.12.2, = 0.00180

From Ref. 1, Eq. 3.8.4a, constant m = 17.647

Calculate reinforcement ratio for critical load case

Design for flexure about A axis is


performed at the face of the column 3.596 ft
at a distance, Dx =

Ultimate moment, 8.569 kip-ft

Nominal moment capacity, Mn = 9.521 kip-ft

Required = 0.00028

Since OK

Area of Steel Required, As = 1.526 in2

Selected bar Size = #3


Minimum spacing allowed (Smin) = 2.000 in

Selected spacing (S) = 7.663 in


Smin <= S <= Smax and selected bar size < selected maximum bar size...

The reinforcement is accepted.


According to ACI 318-05 Clause No- 10.6.4
Max spacing for Cracking Consideration = 7.500 in

UnSafe for Cracking Aspect.

Based on spacing reinforcement increment; provided reinforcement is

#3 @ 7 in o.c.

Print Calculation Sheet

file:///C:/Staad.foundation%205.3/CalcXsl/footing.xml 12/10/2019
CHAPTER V

CONCLUSIONS AND RECOMMENDATIONS

Conclusion

Through the conscientious work on the analysis and designing

of the elevated multipurpose building, the researcher come up to

the conclusions that the proposed design of the elevated

multipurpose building is with structural integrity in a flood prone

area following the rules, regulations, and specifications under

the National Structural Code of the Philippines 2010 Volume 1 and

the National Building Code of the Philippines; The 2004 Revised

Implementing Rules and Regulations of Presidential Decree 1096.

The designed and analyzed elevated structure is proven to

have the structural strength and economy using the calculations

using the STAAD Pro v.81 and adequate Microsoft excel programs

that gave satisfactory results on the overall integrity of the

structure.

The possible cause of failure depends not on the properties

of the material but on the stress system to which it is subjected


and it may not be possible to embody the result for all cases in

one comprehensive formula.

Recommendation

It is highly recommended that the user shall have the minimum

knowledge of the following:

• Microsoft Office Excel - for the computations of data, because

the analyzation and computation of the loads used and needed

to prove the strength of the proposed structure.

• AutoCAD Software – to be able to design the project’s

structure easily and with accurate dimensions of the designed

plans of the structure.

• STAAD Pro – to be able to analyze the design of the structure,

because the application provides a more accurate calculations

for the whole structure.

It is highly recommended that the user shall provide a soil

test analysis for the desired location to come up with an actual

and appropriate design of the structure.

For the researcher recommendation consider the earthquake

loads for a more detailed and substantial analysis and design.


CHAPTER VI

GENERAL NOTES

Standards and References

The following shall govern the design fabrication and

construction of the project.

• National Structural Code of The Philippines (N.S.C.P

2010) Vol. 1, Sixth Edition.

• In the interpretation of the drawing, indicated

dimensions shall govern.

• Construction notes and typical details apply to all

drawings unless otherwise shown or noted. Modify typical

details as directed to meet special conditions.

• All results of the material testing for concrete,

reinforcing bars & structural steel must be noted &

approved by the materials engineer/structural designer.


Notes on Reinforcement

Unless otherwise noted in plans, the yield strength of

reinforcing bars shall be:

• Footings , Footing Beams and Girders -------------

fy = 414 MPa ( 60,000 psi )

• Columns and Shear Walls --------------------------

fy = 414 MPa ( 60,000 psi )

• Beams and Girder ----------------------------------

fy = 414 MPa ( 60,000 psi )

• Non-load Bearing Wall Partitions ,Bedded Slabs , Floor

& Roof Slabs, Parapets ,Catch Basin, Side Walk --------

fy = 275 MPa ( 40,000 psi )

• All reinforcing bars size 10mm or larger shall be

deformed in accordance with the ASTM a-706 bars smaller

Than 10mm May Be Plain.

Notes on Footings

• Footings are designed for an allowance soil bearing pressure

of 96 kpa (2000psf). Contractor shall report to the engineer,

in writing the actual soil conditions uncovered and confirm

actual bearing capacity of soil before depositing concrete.


• Footing shall rest at least 1500mm below natural grade line

unless otherwise indicated in plans. No footing shall rest

on fill.

• In cases where the soil condition is such that the minimum

allowable soil pressure of 96kpa (2000 psf) cannot be attained

at a practical depths the use of micro piles, bored piles, or

driven piles may be adopted in lieu of standard isolated

footings.