Sunteți pe pagina 1din 7

Detailed of Power Calculation of RBS and Other Equipment

Power Calculation Example


RBS 2G 2302 1 unit
Quantity of PSU 1 pcs
PSU Output Maximum (each) 1200 W
PSU efficiency at 200 - 230 V 88 %
Power Consumption 1363.64 W
Constanta Load Sharing Each PSU (1.2 to 1.5) 1.2
Actual Power Consumption 1136.36 W
Round Up 1137 W

RBS 3G 3303 0 unit


Quantity of PSU 0 pcs
PSU Output Maximum (each) 600 W
PSU efficiency at 200 - 230 V 88 %
Power Consumption 0.00 W
Constanta Load Sharing Each PSU (1.2 to 1.5) 1.2
Actual Power Consumption 0.00 W
Round Up 0 W

TOTAL LOAD RBS 2G + 3G 1137 W

Quantity Power
Each PSU Output PSU
NO RBS Type of PSU Consumption
Maximum (W) Efficiency
(pcs) (W)

0 2G RBS
4 2216 2 1500 88% 3409
5 2106 3 1200 88% 4091
6 2116 2 1500 88% 3409

Battery Back Up Unit


3a PBC 6500 ( -48 vdc) 1 1400 88% 1591
3b PBC 6500 (+ 24 Vdc) 1 1200 88% 1364

Transmission
1 ML E 200 - -
2 ML TN amm2p 250 - -
3 ML TN amm6p 400 - -
4 ML TN amm20p 1000 - -

Other Equipment on Site


1 Alcatel Rectifier for TRM only 1 1000 90% 1111
2 Westindo 1 1500 93% 1613
3 Harrif 1 (48 V) 1 1500 95% 1579
4 Harrif 2 (24 V) 1 750 90% 833
5
FILL RBS TYPE & UNIT
(base on RBS product description)
(base on RBS product description)
(base on RBS product description)

(base on RBS product description)


3373.493976/1.2

FILL RBS TYPE & UNIT


(base on RBS product description)
(base on RBS product description)
(base on RBS product description)

(base on RBS product description)


3373.493976/1.2

Constanta Load
Sharing Each Actual Power Round Up Recommended
PSU (1.2 to 1.5 Consumption (W) (W) MCB for 1 PSU
for 200 - 230 V)

1.2 2840.9091 2841 7.75


1.2 3409.0909 3410 6.20
1.2 2840.9091 2841 7.75

1.5 1060.6061 1061


1.5 909.0909 910

- - 0
- - 0
- - 0
- - 0

- 1111.1111 1112
- 1612.9032 1613
- 1578.9474 1579
- 833.3333 834
REMARKS

COVERED BY PSU / RECTIFIER RBS


COVERED BY PSU / RECTIFIER RBS
COVERED BY PSU / RECTIFIER RBS
COVERED BY PSU / RECTIFIER RBS
AC POWER CALCULATION (USING PLN)
Site ID :
Site Name :
Project : Telkomsel Tinem Sumatera Area
Existing Power (PLN): 16.50 KVA

AC POWER
VOLTAGE
NO EQUIPMENT TYPE QTY CONSUMPTION REMARKS
TYPE
(W)
A Radio Cabinet
6 RBS2116 AC 2 5682

B BBU
4a PBC6500 (- 48 Vdc) 0 0
4a PBC6500 (+ 24 Vdc) 0 0

C RECTIFIER
1 Alcatel for TRM only 0 0
2 Westindo 1 modules 0 0
3 Harrif 1 (48 V) 1 modules 4 6316
4 Harrif 2 (24 V) 1 modules 0 0

D TRANSMISSION
ML E 0 -
ML TN amm2p 0 -
ML TN amm6p 0 -
ML TN amm20p 0 -

E OTHERS
1 Air Condition (PK) 2 0 0
2 Obstruction Lightning 250 0 0
3 Misselenous 500 1 500
4 Fire Alarm Panel 250 1 250
5
6

TOTAL POWER CONSUMPTION 12,748.00 Watt


STARTING UP POWER (20%) 2,549.60 Watt
TOTAL POWER REQUIRED 15,297.60 Watt
POWER FACTOR PLN 0.80
TOTAL POWER WITH ACTUAL POWER SUPPLY FROM PLN (80%) 19.12 KVA

POWER RECOMMENDATION 23.00 KVA


EXISTING PLN POWER 16.50 KVA

POWER STATUS UPGRADE PLN POWER FROM 16.5 TO 23 KVA