ePIC/ePIC II Data Logger Setup

Data Logger Setup


Table of Contents
Introduction and Overview............................................................................1
Data Logger Setup ......................................................................................1
View Data Menu................................................................................................... 3
Hourly Logger Data............................................................................................ 4
Daily Logger Data.............................................................................................. 5
Logger Parameters (P890 – P897) .......................................................................... 7

List of Figures
Figure 1: Data Logger Setup screen .................................................................1
Figure 2: Data Logger Setup Flow....................................................................3
Figure 3: View Data Menu display....................................................................4
Figure 4: Hourly Logger Data screen. ...............................................................5
Figure 5: Daily Logger Data screen. .................................................................6

List of Tables
Table 1: Logger Enable Status Values ..............................................................7
Table 2: Hourly Logger Freeze Buffer ...............................................................7
Table 3: Daily Logger Freeze Buffer .................................................................8

November 2007
i
MS-ePICLog-00 / Rev. A
Data Logger Setup ePIC/ePIC II

This page intentionally left blank.

ii November 2007
MS-ePICLog-00 / Rev. A
ePIC/ePIC II Data Logger Setup

Introduction and Overview


The ePIC provides a way to store and retrieve data logger historical records.
Information is stored as integer data in a first in/last out buffer. When a new data
record is added, the existing data moves one position down the buffer. The buffer
contains 240 records. When the buffer is full, the oldest record drops from the
buffer when a new record moves into the buffer.
The controller supports eight independent loggers. The minimum record interval is
one second and the maximum interval is approximately 18 hours (65535 seconds).
All data is averaged over the record interval with a sample rate of one per second.

Data Logger Setup


A great new addition to the controller feature list is the capability to log or store
any RPC parameter data. This data is “logged” at one-second intervals and then
accumulated for viewing in hourly averages and daily averages. Hourly averages
are stored for the previous 24 hours and daily averages for the past 30 days. This
feature can be used to track or monitor any parameter in the controller. Up to eight
parameters can be logged. Refer to the Parameter Listing for a complete listing of
the controller parameters.
If option 9, Data Logger Setup, is chosen from the Setup Menu, the Data
Logger Setup menu as shown in Figure 1 is displayed.

– DATA LOGGER SETUP –

Channel 1 source: >282


Channel 2 Source: 312
Channel 3 Source: 332
Channel 4 Source: 702
Channel 5 Source: 808
Channel 6 Source: 373
Channel 7 Source: 87
Channel 8 Source: 0
Freeze Channel: 0
Clear Log Buffer: (Press ENTER)

SELECT ITEM BY ARROW KEYS


PRESS MODIFY TO CHANGE
PRESS EXIT TO QUIT

Figure 1: Data Logger Setup screen

Refer to Figure 2 for a flow chart of Data Logger programming. Program each
channel as needed.

November 2007
1
MS-ePICLog-00 / Rev. A
Data Logger Setup ePIC/ePIC II

The cursor, which can be moved with the <Up / Down> arrow keys, indicates the
active item. Press <MODIFY> to edit or modify the selected item. When a
subordinate modification screen appears, make any necessary changes to the item
on the Enter New Value line. When complete, press <ENTER > to return to the
Data Logger Setup screen with the new information displayed or press <EXIT>
to abort the process. Eight channels are provided to “log” or store any RPC
parameter data.
Use “freeze channel” to select the channel to display under View Data Æ Hourly /
Daily Logger Data.
To “clear” all channel buffers and the “freeze channel”, select “clear log buffer” and
press <ENTER>. Changing the “source parameter” of a channel does not “clear”
that channel buffer.

2 November 2007
MS-ePICLog-00 / Rev. A
ePIC/ePIC II Data Logger Setup

Figure 2: Data Logger Setup Flow

View Data Menu


This menu allows you to look at different data when selected. Logger data can be
viewed by the hour or by the day.

November 2007
3
MS-ePICLog-00 / Rev. A
Data Logger Setup ePIC/ePIC II

--- VIEW DATA MENU ---

>1 - Dynagraph Data


2 - List Cycle Run Times
3 - Plot Cycle Run Times
4 - List Daily Run Times
5 - Plot Daily Run Times
6 - Run Time Segments
7 - Hourly Logger Data
8 - Daily Logger Data
9 - Aux. I/O Status

SELECT BY # OR ARROW KEYS THEN PRESS ENTER

Figure 3: View Data Menu display.

Hourly Logger Data


Any controller parameter can be “logged” using this function. Up to 8 channels are
provided to log data. Data from the selected “Freeze channel” is displayed. Setup is
done under Setup Menu Æ Data Logger Setup. It is possible to store and view data
such as maximum/minimum loads and casing pressure (or any external I/O data).
Data is gathered and stored each second and then made available to users either as
hourly or daily averages. Refer to Figure 4.
If option 7, Hourly Logger Data, is chosen from the View Data Menu, you may view
hourly average values from any of the 8 logger channels that have been previously
configured to store a parameter’s information. This setup is accomplished through
the Setup Menu Æ Data Logger Setup as previously described.

4 November 2007
MS-ePICLog-00 / Rev. A
ePIC/ePIC II Data Logger Setup

Page 1/3 --- HOURLY LOGGER DATA —

08/19/02@08:00:00 AM 86
08/19/02@07:00:00 AM 86
08/19/02@06:00:00 AM 86
08/19/02@05:00:00 AM 86
08/19/02@04:00:00 AM 86
08/19/02@03:00:00 AM 86
08/19/02@02:00:00 AM 86
08/19/02@01:00:00 AM 86
08/19/02@12:00:00 PM 86
08/19/02@11:00:00 PM 86

Freeze channel: >1

Figure 4: Hourly Logger Data screen.


The cursor indicates the active item. Only one item can be accessed – the “freeze
channel” selection. Press <MODIFY> to change the channel selection. When the
subordinate modification screen is displayed, you can change the “logger channel”
information to be displayed. When complete, press <ENTER> to return to the
Hourly Logger Data screen with the new information displayed or press <EXIT> to
abort the process. Use the PgUp and PgDn keys to move between the three screens
needed to display all 30 days of stored data. If a “Freeze channel” has not been
selected, the screen will display a “Logger Not Frozen” message.
Pressing the F2 key switches the display from Hourly Logger Data to Daily Logger
Data.

Daily Logger Data


Any controller parameter can be “logged” using this function. Up to 8 channels are
provided to log data. Data from the selected “Freeze channel” is displayed. Setup is
done under Setup Menu Æ Data Logger Setup. It is possible to store and view data
such as maximum/minimum loads and casing pressure (or any external I/O data).
Data is gathered and stored each second and then made available to users either as
hourly or daily averages.
If option 8, Daily Logger Data, is chosen from the View Data Menu, you may view
daily average values from any of the 8 logger channels that have been previously
configured to store a parameter’s information. This setup is accomplished through
the Setup Menu Æ Data Logger Setup as previously described. Refer to Figure 5.

November 2007
5
MS-ePICLog-00 / Rev. A
Data Logger Setup ePIC/ePIC II

Page 1/3 --- DAILY LOGGER DATA ---

08/19/02@07:25:11 AM 4657
08/18/02@07:25:11 AM 34075
08/17/02@07:25:11 AM 12532
08/16/02@07:25:11 AM 3560
08/15/02@07:25:11 AM 2471
08/14/02@07:25:11 AM 7390
08/13/02@07:25:11 AM 23131
08/12/02@07:25:11 AM 13244
08/11/02@07:25:11 AM 9876
08/10/02@07:25:11 AM 7690

Freeze channel: >1

Figure 5: Daily Logger Data screen.


The cursor indicates the active item. Only one item can be accessed – the “freeze
channel” selection. Press <MODIFY> to change the channel selection. When the
subordinate modification screen is displayed, you can change the “logger channel”
information to be displayed. When complete, press <ENTER> to return to the Daily
Logger Data screen with the new information displayed. Use the PgUp and PgDn
keys to move between the three screens needed to display all 30 days of stored
data. If a “Freeze channel” has not been selected, the screen will display a “Logger
Not Frozen” message.
Pressing the <F2> key switches the display from Daily Logger Data to Hourly
Logger Data.

6 November 2007
MS-ePICLog-00 / Rev. A
ePIC/ePIC II Data Logger Setup

Logger Parameters (P890 – P897)


Data Logging can be turned “on” by assigning a Parameter number to the Logger.
Data Logging can be turned “off” by changing the assigned Parameter number to
zero (0) for that channel. These parameters control all eight data logger channels.
Table 1 displays the options for this parameter.

Table 1: Logger Enable Status Values


Para # Hex # Attributes Default Description
890 37a rw-w-ee (0) Logger channel 1 source
891 37b rw-w-ee (0) Logger channel 2 source
892 37c rw-w-ee (0) Logger channel 3 source
893 37d rw-w-ee (0) Logger channel 4 source
894 37e rw-w-ee (0) Logger channel 5 source
895 37f rw-w-ee (0) Logger channel 6 source
896 380 rw-w-ee (0) Logger channel 7 source
897 381 rw-w-ee (0) Logger channel 8 source
898 382 rw-b-ra Logger freeze channel (Channels 1 – 8)
899 383 command Clear Logger History. Enter to Clear.

Table 2: Hourly Logger Freeze Buffer


Para # Hex # Attributes Default Description
900 384 ro-w-ra Hour log freeze buffer 00
901 385 ro-w-ra Hour log freeze buffer 01
902 386 ro-w-ra Hour log freeze buffer 02
903 387 ro-w-ra Hour log freeze buffer 03
904 388 ro-w-ra Hour log freeze buffer 04
905 389 ro-w-ra Hour log freeze buffer 05
906 38a ro-w-ra Hour log freeze buffer 06
907 38b ro-w-ra Hour log freeze buffer 07
908 38c ro-w-ra Hour log freeze buffer 08
909 38d ro-w-ra Hour log freeze buffer 09
910 38e ro-w-ra Hour log freeze buffer 10
911 38f ro-w-ra Hour log freeze buffer 11
912 390 ro-w-ra Hour log freeze buffer 12
913 391 ro-w-ra Hour log freeze buffer 13
914 392 ro-w-ra Hour log freeze buffer 14
915 393 ro-w-ra Hour log freeze buffer 15
916 394 ro-w-ra Hour log freeze buffer 16

November 2007
7
MS-ePICLog-00 / Rev. A
Data Logger Setup ePIC/ePIC II

917 395 ro-w-ra Hour log freeze buffer 17


918 396 ro-w-ra Hour log freeze buffer 18
919 397 ro-w-ra Hour log freeze buffer 19
920 398 ro-w-ra Hour log freeze buffer 20
921 399 ro-w-ra Hour log freeze buffer 21
922 39a ro-w-ra Hour log freeze buffer 22
923 39b ro-w-ra Hour log freeze buffer 23

Table 3: Daily Logger Freeze Buffer


Para # Hex # Attributes Default Description
930 3a2 ro-w-ra Daily log freeze buffer 00
931 3a3 ro-w-ra Daily log freeze buffer 01
932 3a4 ro-w-ra Daily log freeze buffer 02
933 3a5 ro-w-ra Daily log freeze buffer 03
934 3a6 ro-w-ra Daily log freeze buffer 04
935 3a7 ro-w-ra Daily log freeze buffer 05
936 3a8 ro-w-ra Daily log freeze buffer 06
937 3a9 ro-w-ra Daily log freeze buffer 07
938 3aa ro-w-ra Daily log freeze buffer 08
939 3ab ro-w-ra Daily log freeze buffer 09
940 3ac ro-w-ra Daily log freeze buffer 10
941 3ad ro-w-ra Daily log freeze buffer 11
942 3ae ro-w-ra Daily log freeze buffer 12
943 3af ro-w-ra Daily log freeze buffer 13
944 3b0 ro-w-ra Daily log freeze buffer 14
945 3b1 ro-w-ra Daily log freeze buffer 15
946 3b2 ro-w-ra Daily log freeze buffer 16
947 3b3 ro-w-ra Daily log freeze buffer 17
948 3b4 ro-w-ra Daily log freeze buffer 18
949 3b5 ro-w-ra Daily log freeze buffer 19
950 3b6 ro-w-ra Daily log freeze buffer 20
951 3b7 ro-w-ra Daily log freeze buffer 21
952 3b8 ro-w-ra Daily log freeze buffer 22
953 3b9 ro-w-ra Daily log freeze buffer 23
954 3ba ro-w-ra Daily log freeze buffer 24
955 3bb ro-w-ra Daily log freeze buffer 25
956 3bc ro-w-ra Daily log freeze buffer 26
957 3bd ro-w-ra Daily log freeze buffer 27
958 3be ro-w-ra Daily log freeze buffer 28
959 3bf ro-w-ra Daily log freeze buffer 29

8 November 2007
MS-ePICLog-00 / Rev. A