Non sheathed
1 H07V-U , H07V-R BS 6004 450/750 2000 4a 081/001/129 single core
(1.5 - 630 mm)
Non sheathed
2 H07V-K BS 6004 450/750 2000 4b 081/001/130 single core
(1.5 - 240 mm)
Armoured cables
5 Cu/XLPE/AWA/PVC BS 5467 600/1000 1997 4 081/001/122 single core
(50 - 630 mm)
6 Armoured cables
6 Cu/XLPE/SWA/PVC BS 5467 600/1000 1997 8 081/001/126 2 - 3 - 4 core
10 (1.5 - 400 mm²)
Armoured cables
7 Cu/XLPE/AWA/PVC BS 5467 600/1000 1997 13 081/001/124 5 cores
(1.5 - 70 mm)
6 Armoured cables
9 Cu/XLPE/SWA/LSF BS 6724 600/1000 1997 8 081/001/127 2 - 3 - 4 core
10 (1.5 - 400 mm)
Armoured cables
10 Cu/XLPE/SWA/LSF BS 6724 600/1000 1997 13 081/001/123 5 cores
(1.5 - 70 mm)
Thermosetting insulated
13 H07Z-U , H07Z-R BS 7211 450/750 1998 3a 081/001/119 non-sheated cable.Single core
(1.5 - 300 mm)
3. Yangına
Yangýnadayanıklılık / Fire
testitesti Resistant (IEC(IEC
60331 /
VDE 472.814 / BS 6387)
3. dayanýklýlýk / Fire Resistant 60331)
Yangýn sýrasýnda hayati önem taþýyan
sistemi
yangýnavedayanýklýlýðý
yangın pompaları) çalışması için
kesintisiz iletilmesi gerekmektedir. Nexans
86
In case of fire, some essential circuits must maintain the power supply for vital safety
equipment (emergency lighting, alarm systems and fire pumps...). The circuit
integrity performance under fire conditions is assessed on the basis of various tests
4. Duman Yoðunluðu / Smoke Density (IEC 61034)
which either
Yangýn measure
sýrasýnda resistance
kablodan yayýlantoduman
fire or oranýnýn
in combination measure resistance
görüþ mesafesini engellememesi gerekmektedir.
to fire with water spray and resistance to fire with mechanical shock. To meet such
NEXANS'ýn yangýna dayanýklý kablolarý IEC 61034-2 testinin koþullarýný saðlamaktadýr.
requirements NEXANS proposes fire resistant cables with mica tape + XLPE insulation.
These cable types meet IEC 60331, VDE 472.814, BS 6387 specifications.
In case of fire, smoke emission evolving from cables must be very low. NEXANS Fire Performance Cables
conform to the requirements of IEC 61034-2.
87
H07Z-R (HAR)
H07Z-U (HAR)
Yangına Dayanıklılık Testi / Fire Resistant( BS 6387 - D2)
450/750 V halojensiz, alev iletmeyen kablolar
Test 450/750V
Category Flame Temperaturefree,
halogen Testflame
Duration retardant cables
Used Su in veenergy
Yangına networks
dayanıklılık Testi
Resistance to Fire with Water ( BS 6387 - D3)
in refineries, mines, hotels, schools, tunnels, high
constructions, hospitals, power plants, data processing centers, business
Test Category Flame Temperature
centers where there is a riskTestofDuration
fire.
Yapýsý / Construction
W 650 ºC 15 min
1- Ýletken / Conductor: Bakýr / Copper
1
Y 750 ºC 15 min
Standartlar / Standards
Z 950 ºC 15 min
BS 7211, HD 22.9
Every 30 seconds mechanical shock device damages to BS 6387-D4 Mekanik darbe ve Yangına dayanıklılık Testi
the panel. Fire resistant with Mechanical shock according to BS 6387-D4
Her 30 saniyede bir panele mekanik şok uygulanmaktadır.
Teknik veriler / Technical Datas
Max. çalýþma sýcaklýðý 90 ºC
Max. kýsa devre sýcaklýðý: 250 ºC
Max. operating temperature 90 ºC
Short circuit temperature: 250 ºC
Cl
Br
Fl
Flame retardant Low smoke Halogen free Low toxicity Low corrosivity -20 / +60 °C
IEC 60332 - 1-2 IEC 61034 IEC 60754-1 IEC 60754-1 IEC 60754-2