Sunteți pe pagina 1din 20

Web Seminar:

New Web Examples


Access via Terminal Services and
Web Navigator
ƒ iPhone

© Siemens AG 2010. All rights reserved.


Installation on the WinCC Server (1)

1) Perform complete software installation


ƒ Microsoft Windows 2003 Server
ƒ Office 2003/2007
ƒ SIMATIC WinCC
ƒ SIMATIC WinCC
Wi CC W
Web
bNNavigator
i t
ƒ Other required software
2) Installation of the Microsoft Terminal Services

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Installation on the WinCC Server (2)

Installation of the Microsoft Terminal Services

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Installation on the WinCC Server (3)

Installation of the Microsoft Terminal Services

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Installation on the WinCC Server (4)

Installation of the Microsoft Terminal Services

Right-Click

Installation …..
Reboot …..

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Installation on the WinCC Server (5)

Important
p Information!
ƒ After the installation of the Terminal Server Services, no other software must
be installed!
ƒ Procedure:
ƒ Deinstallation of the Terminal Server Services
ƒ Installation of the software
ƒ New installation of the Terminal Server Services

ƒ Windows 2003 Server includes 5 Client Access Licenses for Terminal Server
clients. If more thin clients are needed, the required quantity has to be ordered
from Microsoft in the form of CALs.
ƒ Since with WinCC alwaysy the same Windows user is used that opens
p a new
session, always just one license is needed for the Terminal Server.
© Siemens AG 2010. All rights reserved.
Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Installation on the WinCC Server (6)

Creation of a Windows login for the Terminal Client access

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Installation on the WinCC Server (7)

ƒ Add the new user to the group “Remote Desktop Users”:

ƒ Log in once to the server as the new user so that the user receives a local profile.
ƒ If the Terminal Server Services are deinstalled (to install new software), all users are
removed d ffrom the
th group “Remote
“R t Desktop
D kt Users”
U ” anddhhave tto b
be added
dd d anew.

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Installation on the WinCC Server (8)

ƒ Create a shortcut to the WinCC Viewer on your desktop.


ƒ The Web client can be found at:
“C:\Program Files\Siemens\WinCC\WebNavigator\Client\bin”

ƒ Copy this shortcut to the desktop of


the Terminal Client user:
© Siemens AG 2010. All rights reserved.
Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Installation on the WinCC Server (8)

ƒ Test the Terminal Server:


ƒ Start
St t Æ Run
R Æ “mstsc”
“ t ”

ƒ Enter the server name or the


IP of the Terminal Server,
the user name & password.
ƒ Click
Cli k on “C
“Connect”.
t”
ƒ If the connection is successful,
log off again from the session.
ƒ C
CAUTION:
U O If a sshutdown
u do iss activated
ac a ed in the
e remote
e o e session,
sess o , the
eeentire
e co
computer
pu e will be
shut down. This can be prevented via policies and registry keys.
© Siemens AG 2010. All rights reserved.
Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Installation on the WinCC Server (9)

ƒ On the server, start your WinCC project; configure the Web Navigator
(S up off Web
(Set W b View
Vi Publisher
P bli h + W
Web bCConfigurator
fi + Wi
WinCC
CC user))
ƒ Start WinCC Runtime and test the Web client locally
ƒ Now open a session with “mstsc” and in the session, start the Web client.
ƒ If the Web client is functioning in the remote session, you can start to
prepare the mobile device for the access.

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
WinCC on Mobile Devices

A l iPh
Apple iPhone

WinCC +
Nokia
o a N97
9
Web Navigator
WLAN

Access Point

HTC/MDA
© Siemens AG 2010. All rights reserved.
Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
WinCC @ iPhone

Prerequisites:
ƒ WLAN activated on iPhone
ƒ Test: Ping from WinCC server to the IP of the iPhone
ƒ App for RDP client connection
WLAN Configuration

Required Apps
© Siemens AG 2010. All rights reserved.
Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
WinCC @ iPhone – The right App

ƒ Several apps are available in the App Store, with which an RDP connection
can be
b established:
bli h d

Recommended App

} Only RDP Connection to


the Console possible
(Session 0)

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
WinCC @ iPhone – iTap RDP Client

1
iTap RDP Client
Information about
the App
2

3
4

1 Delete
e ete connections
co ect o s
2 Edit current connection
3 Establish connection
4 Configure new connection
© Siemens AG 2010. All rights reserved.
Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
WinCC @ iPhone – Configuring the Connection

} IP or server name

3389 -> RDP d


default
f l port

Specify
p y Windows user name
and password

Resolution for the


remote session

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
WinCC @ iPhone – Activating the Connection

Establish connection …

Operation
p in the
remote session

Connection to the server is OK

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
WinCC @ iPhone – Web Client in Terminal Session

ƒ Start the Web client via the icon on the desktop


ƒ Zoom using two fingers to optimally view the window

ƒ Enter the name of the server, the WinCC user name and the password
ƒ At “Graphics
Graphics Runtime”,
Runtime , set the start screen and activate “Fit
Fit screen
screen”

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
WinCC @ iPhone – Web Client in Terminal Session

ƒ You can now operate WinCC Runtime


ƒ To open the keyboard, drag three fingers on
the display from top to bottom
ƒ With CTRL + ALT + P, the configuration of
the Web client can be called up
ƒ To end the remote session, drag three
fingers on the display from left to right

© Siemens AG 2010. All rights reserved.


Jan-2010 Webinar WinCC Web Examples 2010 Industry Sector
Thank you for your attention!

© Siemens AG 2010. All rights reserved.