3P Series Molded Case Circuit Breakers


Overview
Overview Features
Designed to provide branch and feeder • UL489 listed performance for branch
circuit overcurrent protection and
circuit protection in industrial control disconnecting means
panels, this line of Molded Case Circuit • Patented contact conductor designs
Breakers supplies protection against featuring high-speed “blow-open”
overload in conductors and short cir- action, providing superior performance
cuit in connected equipment such as when high level fault currents produce
extra-ordinary electromechanical forces
motors. They are UL listed for instal-
lation in UL 508 control panels. Their • Advanced arc extinguishing technology
small size, in relation to standard circuit • Toggle handle provides three positions
breakers or other comparable devices, (on/off/tripped) along with visual
indicators
saves panel space. Four frame sizes
• Manufactured in ISO 9000 certified
and all standard accessories are avail- facilities
able. • HACR (heating, air conditioning and Manufactured by Eaton Corporation
refrigeration) rated
Listings • G-Frame and F-Frame breakers are
• UL 489 MCCB, File: E7819 suitable for reverse feed
• Field-installed accessories: • K-Frame and L-Frame breakers include
UL file E64983 3-pole adjustable magnetic trip.
• CSA 22.2 No.5, File: 43556
• IEC 157-1
• NEMA Standards Pub. No. AB1-1993

Note: These parts available for sale to North American locations only.

Molded Case Circuit Breakers Technical Specifications


UL 489 Interrupting Ratings
Volts Type Federal
Circuit Breaker Ampere Rat- No. (rms Symmetrical Amperes) (kA)
of Specification Volts AC (50/60 Hz) Volts DC
Type ing at 40°C Poles
AC DC Trip* W-C-375b
240 480 600 250**
G-Frame 15 -100 3 480 250 N.I.T.U 13b 65 22 – 10
F-Frame 60 - 225 3 600 250 N.I.T.U 22a 65 35 18 10
K-Frame 250 - 400 3 600 250 I.T.U 23a 65 35 25 10
L-Frame 400 - 600 3 600 250 I.T.U 23a 65 35 25 22
*Note: N.I.T.U denotes non-interchangeable trip unit. I.T.U denotes interchangeable trip unit.
**Note: For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker

Molded Case Circuit Breakers Part Numbering System


G 3P - 020 - AUX
Accessory Description Code
AUX: auxiliary contact UVAC: undervoltage release
STAC: shunt trip AC UVDC: undervoltage release
STDC: shunt trip DC

Amp Rating

3 Pole

Molded Case Circuit Breaker Series (by frame size)


G: 15 to 100 Amp F: 60 to 225 Amp
K: 250 to 400 Amp L: 400 to 600 Amp

tCPR-30 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5


For latest prices, please check AutomationDirect.com

3P Series Molded Case Circuit Breakers


15 - 100 Amp G-Frame
G-Frame circuit breakers are available as a suitable for reverse feed use. All breakers
single unit, or with accessories pre-installed include base mounting hardware for panel
only. Accessories are not field installable mount applications.
on this frame size. G-Frame breakers are

G-Frame Series Three Pole Molded Case Circuit Breakers


Pre-Installed Ampere Voltage Interrupt
Part Number Price Description Accessories* Rating Capacity
G3P-015 $268.00 Molded case circuit breaker with non- None
adjustable thermal magnetic trip; line 15
G3P-015-AUX $320.00 and load lug terminals included. With auxiliary contact, SPDT
G3P-020 $268.00 Molded case circuit breaker with non- None
adjustable thermal magnetic trip; line 20
G3P-40 G3P-020-AUX $320.00 and load lug terminals included. With auxiliary contact, SPDT
G3P-025 $268.00 Molded case circuit breaker with non- None 25
adjustable thermal magnetic trip; line
G3P-030 $268.00 and load lug terminals included. None
G3P-030-AUX $320.00 With auxiliary contact, SPDT
G3P-030-STAC $320.00 Molded case circuit breaker with non- With 120 VAC shunt trip 30
adjustable thermal magnetic trip; line
G3P-030-STDC $320.00 and load lug terminals included. With 24 VDC shunt trip
G3P-030-UVAC $320.00 With 120 VAC undervoltage release
G3P-040 $268.00
Molded case circuit breaker with non-
None 40

GHMVD12B G3P-050 $268.00 adjustable thermal magnetic trip; line None 50


65kA
and load lug terminals included. 240VAC
G3P-060 $268.00 None 480VAC 22kA
10kA
G3P-060-AUX $320.00 With auxiliary contact, SPDT
G3P-060-STAC $320.00 Molded case circuit breaker with non- With 120 VAC shunt trip 60
adjustable thermal magnetic trip; line
G3P-060-STDC $320.00 and load lug terminals included. With 24 VDC shunt trip
G3P-060-UVAC $320.00 With 120 VAC undervoltage release
G3P-070 $268.00
Molded case circuit breaker with non-
None 70
G3P-080 $268.00 adjustable thermal magnetic trip; line None 80
and load lug terminals included.
G3P-090 $268.00 None 90
F0S03C G3P-100 $268.00 None
G3P-100-AUX $320.00
Molded case circuit breaker with non-
With auxiliary contact, SPDT
G3P-100-STAC $320.00 adjustable thermal magnetic trip; line With 120 VAC shunt trip 100
and load lug terminals included.
G3P-100-STDC $320.00 With 24 VDC shunt trip
G3P-100-UVAC $320.00 With 120 VAC undervoltage release
*Note: Available accessories are pre-installed on G-Frame and F-Frame Molded Case Circuit Breakers. They are not field installable
or interchangeable. G-frame terminals are factory-installed only. No replacement terminals available.
** For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker

3TA100G6K G-Frame Accessory Selection Guide


Part Number Price Description
GHMVD06B $69.00 NEMA 1/12 rotary handle for G-Frame. Position indicating; lock-off feature. Shaft length: 6”
GHMVD12B $76.00 NEMA 1/12 rotary handle for G-Frame. Position indicating; lock-off feature. Shaft length: 12”
F0S03C $297.00 NEMA 1/12 flex shaft cable operator for G-Frame. Flange mounted. Lockable. Cable length: 3’
F0S06C $331.00 NEMA 1/12 flex shaft cable operator for G-Frame. Flange mounted. Lockable. Cable length: 6’
3TA100G6K $54.00 Multi-wire connector to allow 6 wires to be connected to the G-frame. UL for copper only. 14-6AWG. Package of 3
GDIN $9.25 DIN rail clip adapter to allow mounting of G-Frame unit on 35mm DIN rail. Pkg of 1 includes mounting hardware.
GDIN
G-Frame Electrical Ratings
Frequency Amperes Contact Ar-
Volts
AWG Wire Range Specifications rangement
G-Frame Auxiliary Switch 240 VAC 50/60 Hz 6 1a/1b - SPDT
Circuit Ampere Wire AWG Metric Wire 120 VAC 50/60 Hz 1.1
Breaker Rating Type Wire Range mm2 G-Frame Shunt Trip
Range 24 VDC DC 5.7
15 - 20 14 - 10 2.5 - 4 120 VAC 50/60 Hz 0.05
G-Frame Cu/AI
25 - 100 10 - 1/0 4 - 50 G-Frame Undervoltage Dropout Voltage Pickup Voltage
Release Mechanism Min Max Max
38.5 77.0 VAC 93.5 VAC
VAC

tCPR-31 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5


For latest prices, please check AutomationDirect.com

3P Series Molded Case Circuit Breakers


15 - 100 Amp G-Frame
T ype G 3P 15-100 A m peres 3 Pole

CURRENT IN PERCENT OF BREAKER TRIP UNIT RATING

100,000
20,000

30,000

40,000

50,000
60,000
70,000
80,000
90,000
10,000
1000

2000

3000

4000

5000
6000
7000
8000
9000
100

200

300

400

500
600
700
800
900
50
60
70
80
90
10,000 10,000
Circuit Breaker Time/Current Curves

2 HOURS
2 HOURS

Catalog Type G3P 15-100 Amperes


For application and coordination purposes only. Based on
5,000 40˚C ambient, cold start. Connected with four (4) feet of 5,000

1 HOUR
rated wire (60/75˚C) per terminal. Tested in open air with
1 HOUR

current in all poles except for instantaneous trip, see below


˚
3,000 3,000

2,000 2,000
M ax im um Vo lts
Breaker AC Volts
Type 60 Hz
G 3P 480
1,000 1,000

Breaker Instantaneous Trip, Amperes


C ontin uous A mper es Single Pole 2 Poles in Series
15-60 500-1300 400-1100
500 70-100 1300-1800 700-1300 500

Interrupting Rating (UL Listed)


Breaker Symmetrical RMS Amperes
300 Type 240 Volts 480 Volts 300
G3P 65,000 22,000
200 200

100 100

1 MINUTE
1 MINUTE

50 50

30 30

20 20

10 10

M axim um
M inim um 5
5

3 3

2 2

TIME IN SECONDS
1 1

.5 .5
TIME IN SECONDS

.3 .3

.2 .2

.1 .1

.05 .05

.03 .03

Instantaneous Trip (See Tabulation above)


.02 .02

Maximum Interrupting Time

Interrupting Rating (See Tabulation Above


.01 .01

.005 .005

.003 .003

.002 .002

.001 .001
1000

2000

3000

4000

5000
6000
7000
8000
9000
100

200

300

400

500
600
700
800
900

10,000

20,000

30,000

40,000

50,000
60,000
70,000
80,000
90,000
100,000
50
60
70
80
90

CURRENT IN PERCENT OF BREAKER TRIP UNIT RATING C urve


TIME IN SECON

tCPR-32 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5


For latest prices, please check AutomationDirect.com

3P Series Molded Case Circuit Breakers –


Dimensions
15 - 100 Amp G-Frame
inches(mm)

60 - 225 Amp F-Frame


inches(mm)

tCPR-46 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5


For latest prices, please check AutomationDirect.com

3P Series Molded Case Circuit Breakers –


Accessories
Field Mountable Accessories
Rotary Handle
A universal rotary handle is available for each frame size of molded case
circuit breaker. The handles are suitable for use with NEMA 1, 12, 4 or
4x enclosures. Features include the following:
• Large handle easily accommodates gloves
• Global ON/OFF markings (I/ON, O/OFF) and TRIP indication on handle
• Access Handle Lock-Off by pressing arrow on handle insert
• Door interlock and defeater
• Metal shaft and base
• Pipe valve operation (ON=Vertical, OFF=Horizontal) with 90 degree rotation
• UL 489, IEC 947-1/-2, CSA

Rotary Handle Accessory Selection Guide


GHMVD12B Part Number Price Description
GHMVD06B $69.00 NEMA 1/12 black rotary handle for G-Frame MCCB. Shaft length: 6”

GHMVD12B $76.00 NEMA 1/12 black rotary handle for G-Frame MCCB. Shaft length: 12”

FHMVD12B $76.00 NEMA 1/12 black rotary handle for F-Frame MCCB. Shaft length: 12”

HM1R12X $108.00 NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 12”

HM1R24X $122.00 NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 24”

KHMVD12B $110.00 NEMA 1/12 black rotary handle for K-Frame MCCB. Shaft length: 12”

HM3R12X $133.00 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 12”

HM3R24X $148.00 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 24”

LHMVD12B $127.00 NEMA 1/12 black rotary handle for L-Frame MCCB. Shaft length: 12”

HM4R12X $174.00 NEMA 4/4X black rotary handle for L-Frame MCCB. Shaft length: 12”

HM4R24X $183.00 NEMA 4/4X black rotary handle for L-Frame MCCB. Shaft length: 24”
HM1R12X

Flex Shaft™ Flexible Handle


Meeting crucial time limits for shutdown procedures is easier with an
externally mounted handle. The flexible handle makes it possible to
operate the circuit breaker externally and can be used in enclosures of
varying depths and heights. It can be used with NEMA 1, NEMA 3R and
NEMA 12 enclosures, and it accepts up to three padlock shackles.
Note: A
 minimum bending radius of four inches is necessary for proper operation.

Flexible Handle Accessory Selection Guide


Part Number Price Description
F0S03C $297.00 NEMA 1/12 flex shaft cable operator for G-Frame MCCB. Cable length: 3’

F0S06C $331.00 NEMA 1/12 flex shaft cable operator for G-Frame MCCB. Cable length: 6’
F0S03C F1S03C $331.00 NEMA 1/12 flex shaft cable operator for F-Frame MCCB. Cable length: 3’

F1S06C $360.00 NEMA 1/12 flex shaft cable operator for F-Frame MCCB. Cable length: 6’

F3S03C $395.00 NEMA 1/12 flex shaft cable operator for K-Frame MCCB. Cable length: 3’

F3S06C $417.00 NEMA 1/12 flex shaft cable operator for K-Frame MCCB. Cable length: 6’

F4S04C $452.00 NEMA 1/12 flex shaft cable operator for L-Frame MCCB. Cable length: 4’

F4S06C $522.00 NEMA 1/12 flex shaft cable operator for L-Frame MCCB. Cable length: 6’

tCPR-48 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5


For latest prices, please check AutomationDirect.com

3P Series Molded Case Circuit Breakers –


Accessories
Field Mountable Accessories Auxiliary Contact
The auxiliary contact provides circuit breaker contact status information
by monitoring the position of the molded cross bar which contains the
moving contact arms. The auxiliary switch is used for remote indication
and interlock system verification, and consists of one SPDT switch housed
in a plug-in module. Each SPDT switch has one ‘a’ and one ‘b’ contact.
When the circuit breaker contacts are open, the ‘a’ contact is open and
the ‘b’ contact is closed.
Note:Field installable auxiliary contacts are not available for the G and F frame breakers.
For G and F frame auxiliary contacts, order breakers with -AUX as part of the part
number. Please see G and F-frame sections for available selections.

A1X3PK
Auxiliary Contact Accessory Selection Guide
Part Number Price Description
A1X3PK $195.00 Field installable auxiliary contact for K-Frame MCCB, SPDT, 18” pigtail leads
A1X4PK $200.00 Field installable auxiliary contact for L-Frame MCCB, SPDT, 18” pigtail leads

K-Frame Electrical Ratings 1,2 L-Frame Electrical Ratings 1,2


Max Frequency Max Dielectric Max Frequency Max Dielectric
Amperes Withstand Notes Amperes Withstand Notes
Volts Volts
Voltage Voltage
1. Endurance: 5000
600 50/60 Hz 6 1. Endurance: 5000 600 50/60 Hz 6 electrical operations
electrical operations L-Frame plus 1000 mechanical
K-Frame 125 DC 0.503
plus 1000 mechanical Auxiliary 125 DC 0.503 2500 operatons.
Auxiliary 2500 operatons.
Switch 2. Pigtail wire size: 18
2. Pigtail wire size: 18 AWG (0.82 mm²)
Switch 250 DC 0.253 AWG (0.82 mm²) 250 DC 0.25 3
3. Non-inductive load
3. Non-inductive load

Undervoltage Release
This product monitors a voltage (typically a line voltage) and trips the circuit breaker
when the voltage falls to between 70% and 35% of the solenoid coil rating. It consists
of a continuous rated solenoid, with a plunger and tripping lever mounted in a
plug-in module.
Note: The undervoltage release is a pre-installed accessory on G-Frame and F-Frame breakers.

Undervoltage Release Accessory Selection Guide


UVH3LP21K Part Number Price Description
UVH3LP08K $302.00 Field installable 110 - 127 VAC undervoltage release for K-Frame MCCB
UVH4LP08K $323.00 Field installable 110 - 127 VAC undervoltage release for L-Frame MCCB
UVH3LP21K $302.00 Field installable 24 VDC undervoltage release for K-Frame MCCB
UVH4LP21K $346.00 Field installable 24 VDC undervoltage release for L-Frame MCCB

Dropout Pickup Dropout Pickup


Supply Voltage Voltage VA Notes Supply Voltage Voltage VA Notes
Voltage Voltage
K-Frame Min Max Max L-Frame Min Max Max
Undervolt- 24 VDC 8.4 16.8 20.4 3.1 1. Endurance: 5000 Undervolt-
age Release electrical opera- age Release 24 VDC 2 8.4 16.8 20.4 3.1 1. Endurance:
5000 electrical
Mechanism 110 VAC 1.8 tions plus 1000
Mechanism 110 VAC 1.8
2
mechanical operations plus
120 VAC2 44.5 77.0 93.5 2.1 1000 mechani-
operatons. 120 VAC2 44.5 77.0 93.5 2.1 cal operatons.
2. 50/60 Hz
127 VAC2 2.4 127 VAC2 2.4 2. 50/60 Hz

tCPR-49 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5


For latest prices, please check AutomationDirect.com

3P Series Molded Case Circuit Breakers –


Accessories
Field Mountable Accessories
Shunt Trip
The Shunt Trip provides remote controlled tripping of the circuit breaker. Consisting of
an intermittent rated solenoid with a tripping plunger and a cutoff switch assembled
to a plug-in module, shunt trip coils are designed to be applied at specific AC or DC
voltages.

Shunt Trip Accessory Selection Guide


Part Number Price Description
SNT3P11K $302.00 Field installable 110/240 VAC / 110/125 VDC shunt trip for K-Frame MCCB.
SNT4RP11K $346.00 Field installable 110/240 VAC shunt trip for L-Frame MCCB
SNT3P04K $302.00 Field installable 12/24 VAC/DC shunt trip for K-Frame MCCB SNT3P04K
SNT4RP03K $346.00 Field installable 12/24 VAC/DC shunt trip for L-Frame MCCB

Supply Min Supply Min


Operating VA Voltage Operating VA Notes
Voltage Voltage Voltage
VAC 50/60 Hz VDC
K-Frame 12 9
45 12
8.4
35 1. Endurance: 5000
electrical operations
24 200 24 170
Shunt plus 1000 mechanical
Trip 110 100 110 77 110 operatons.
2. Approx. unlatching
120 120 120 77 130 time: 6 ms
127 140 125 77 140 Approx. total circuit
60 breaker contact open-
208 420 – – – ing time: 8 ms
220 470 – – –
240 550 – – –

Supply Min Min


VA Supply
Voltage Operating Operating VA Notes
Voltage
Voltage Voltage
VAC 50/60 Hz VDC
12 45 12 35 1. Endurance: 5000
L-Frame 9 9 electrical operations
24 200 24 170
Shunt plus 1000 mechanical
Trip 110 100 – – – operatons.
2. Approx. unlatching
120 120 – – – time: 6 ms
127 140 – – – Approx. total circuit
60 breaker contact open-
208 420 – – – ing time: 18 ms
220 470 – – –
240 550 – – –

tCPR-50 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5


For latest prices, please check AutomationDirect.com

3P Series Molded Case Circuit Breakers –


Accessories
Field Mountable Accessories
Six-wire Connector
This is a field installable multi-wire connector which allows six wires to be connected
to the load side (OFF) end terminals. It is used to distribute the load from the circuit
breaker to multiple devices without the use of separate distribution terminal blocks.
UL listed for copper only as used on the load side (OFF) end. Includes mounting
hardware, insulators and tin-plated aluminum connectors.

Six-wire Connector Accessory Selection Guide


Part Number Price Description 3TA100G6K
3TA100G6K $54.00 For G-Frame MCCBs. Pkg. of 3. Wire size: 14 - 6 AWG, copper
3TA150F6K $54.00 For F-Frame MCCBs. Pkg. of 3. Wire size: 14 - 6 AWG, copper

Replacement Lug Kit


Line and load terminals provide wire connecting capabilities for specific ranges of
continuous current ratings and wire types. Replacement lugs will accept wire types
Cu/AI as standard.

Replacement Lug Kit Accessory Selection Guide


Part Number Price Description
3TA225FD $80.00 Replacement lug kit for F-Frame MCCB. Wire range (1) #4-4/0 (25-95 mm²). 3TA401K
Package of (3) terminals.
Replacement lug kit for K-Frame MCCB. Wire range (2) 2/0-250 kcmil or (1) 2/0-500
3TA401K $84.00 kcmil (70-240 mm²). 3-pole kit (one terminal per pole and one terminal cover).
Replacement lug kit for L-Frame MCCB. 3-pole kit (one terminal per pole and one
3TA603LDK $104.00 terminal cover). Wire range 400-500 AWG (185-240 m²), 2 conductors.
Note: G-frame terminals are factory-installed only. No replacement terminals available.

Din Rail Mounting Clip


Din Rail Mount Clip Accessory Selection Guide
Part Number Price Description
GDIN $9.25 Clip for mounting G-Frame to 35 mm Din rail. Mounting hardware included. Pkg of 1

GDIN
NEMA 12 Safety Door Hardware
Type C361 door interlocking safety handle kits are designed for use with AutomationDi-
rect 3P series MCCBs and flexible handle, when mounted in an SDN12, or equivalent,
enclosure. These handles secure the SDN12 enclosure, protecting against unauthor-
ized entry while the MCCB is in the ON position. Use them on enclosures with right
side flanges only and material thickness from 16 gauge through 3/16”. All mounting
hardware is included for enclosures up to 40” tall. The addition of the C361KR roller
kit is necessary for enclosures taller than 40” that require a 3-point latch. See SDN12
Handle
Enclosures section for enclosure specifications in OFF
position
Safety Door Hardware Selection Guide
Part Number Price Description
Handle length: 4”. Mounting hardware included for enclosures up to 40” tall. For Release
C361KJ4 $240.00 taller enclosures that require a 3-point latch, the C361KR (purchase separately) will Screw
also be needed.
Handle length: 6”. Mounting hardware included for enclosures up to 40” tall. For
C361KJ6 $253.00 taller enclosures that require a 3-point latch, the C361KR (purchase separately) will
also be needed.
Door Interlocking safety roller kit for use with the C361KJ4 and C361KJ6 safety
C361KR $55.00 handle kits when the SDN12 series enclosure is taller than 40 inches and 3-point
latching is required. Kit includes roller and all hardware.
Safety Handle
Note: The 1/4” x 1/2” standard mill rectangular locking bar is not supplied with these kits. The bar is
supplied with the enclosures.
shown on enclosure

tCPR-51 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5

S-ar putea să vă placă și