Version 2.01
ZTE CORPORATION
NO. 55, Hi-tech Road South, ShenZhen, P.R.China
Postcode: 518057
Tel: (86) 755 26771900
Fax: (86) 755 26770801
URL: http://ensupport.zte.com.cn
E-mail: support@zte.com.cn
LEGAL INFORMATION
The contents of this document are protected by copyright laws and international treaties. Any reproduction or distribution of
this document or any portion of this document, in any form by any means, without the prior written consent of ZTE CORPO-
RATION is prohibited. Additionally, the contents of this document are protected by contractual confidentiality obligations.
All company, brand and product names are trade or service marks, or registered trade or service marks, of ZTE CORPORATION
or of their respective owners.
This document is provided “as is”, and all express, implied, or statutory warranties, representations or conditions are dis-
claimed, including without limitation any implied warranty of merchantability, fitness for a particular purpose, title or non-in-
fringement. ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the
information contained herein.
ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject
matter of this document. Except as expressly provided in any written license between ZTE CORPORATION and its licensee,
the user of this document shall not acquire any license to the subject matter herein.
ZTE CORPORATION reserves the right to upgrade or make technical change to this product without further notice.
Users may visit ZTE technical support website http://ensupport.zte.com.cn to inquire related information.
Revision History
Configuration
Preparation
Table of Contents
Preparing Documents .......................................................... 1
Preparing Tool and Software................................................. 1
Checking Configuration Conditions ........................................ 2
Preparing Documents
The following documents should be prepared.
� ** Network Planning Proposal
� ZXMW PR10 S400&S500 Digital Microwave System Configura-
tion Guide
Checking Configuration
Conditions
Before performing data configuration, check whether the following
conditions are satisfied.
� The NE equipment is powered on correctly.
� The communication on links among NE equipments is normal.
Data Planning
Table of Contents
Networking Information....................................................... 3
NE Properties ..................................................................... 4
Protection Property ............................................................. 5
IDU Information ................................................................. 5
ODU Information ................................................................ 5
IP Address Planning ............................................................ 5
Networking Information
Connection The following should be noted
between the
second-level 1. There is only one IP address of Q port, not R port.
equipments with
one jump
2. The IP address of Q port of two equipments should be set in
same network area.
NE Properties
TABLE 1 NE PROPERTIES
Item Property
Name 10.61.120.249
Item Property
location shanghai
Protection Property
TABLE 2 PROTECTION PROPERTY
Parameter Value
IDU Information
TABLE 3 IDU PROPERTIES
Parameter Value
Bandwidth 28 MHz
ODU Information
TABLE 4 ODU PROPERTIES
Parameter Value
IP Address Planning
TABLE 5 IP ADDRESS PLANNING
Table of Contents
Logging in to Web CIT ......................................................... 7
Configuring Protection Type ................................................15
Configuring E1 Capability....................................................17
Configuring Modulation Mode ..............................................18
Configuring System Bandwidth ............................................20
Configuring ODU Frequency ................................................22
Performing ODU Frequency Scanning ...................................24
Configuring Transmitting Power of ODU ................................28
Equipment IP Address Configuration.....................................31
Configuring SNMP Manager .................................................36
Configuring Trap Address ....................................................37
Setting NE Time ................................................................39
Controlling QoS Ethernet Flow Rate......................................41
Configuring Switch Level ....................................................46
Upgrading System .............................................................47
Checking Transceiving End Switch Log ..................................49
Type user name and password and click the LOGON button to
access the Web CIT system, as shown in Figure 5.
8. Type ipconfig /all and press Enter key. The command line
window displays the IP address of the destination IDU, as
shown in Figure 12.
Postrequisite Type user name and password and click the LOGON button to log
in to the Web CIT system.
END OF STEPS
Configuring E1 Capability
Prerequisites The Web CIT system is logged on successfully.
Context S400: S400 can be configured with 2 × E1, 4 × E1, 8 × E1 or 16 ×
E1.
S500: S500 can be configured with 2 × E1, 4 × E1, 8 × E1 or 16 ×
E1. If S500 with E1TU, it can be configured with 32 × E1.
Steps 1. Click Configuration > System > System in the left menu
bar, as shown in Figure 17.
Configuring Modulation
Mode
Prerequisites The Web CIT system is logged on successfully.
Context The system modulation mode is related to the maximum service
capacity and the system bandwidth.
14 MHz 8 E1 20 Mbps
28 MHz 16 E1 40 Mbps
14 MHz 16 E1 40 Mbps
Steps 1. Click Configuration > System > System in the left menu
bar, as shown in Figure 19.
Configuring System
Bandwidth
Prerequisites The Web CIT system is logged on successfully.
Context The system bandwidth is related to the maximum service capacity
and the system modulation mode. For details, refer to Configuring
Modulation Mode.
Steps 1. Click Configuration > System > System in the left menu
bar, as shown in Figure 21.
2. Select the bandwidth from the Band Width drop-down list box
on the right part of the configuration interface, as shown in
Figure 22.
13 GHz 266
26 GHz 1008
38 GHz 1260
Steps 1. Click Configuration > ODU > Frequency in the left menu
bar, as shown in Figure 23.
END OF STEPS
Configuring Transmitting
Power of ODU
Prerequisites The Web CIT system is logged on successfully.
Steps 1. Click Configuration > ODU > TPC in the left menu bar, as
shown in Figure 29.
2. Select Manual from the TPC Mode drop-down list box on the
right part of the configuration interface.
3. Select transmitting power of ODU from the drop-down list box
of Tx Power (dBm) on the right part of the configuration in-
terface, as shown in Figure 30.
Note:
For S400, if you want to modify Tx Power, Tx Status must be
Unmute.
For S500 without 1+1 protection, if you want to modify Tx
Power, Tx Status must be Unmute.
For S500 with 1+1 protection, if you want to modify Tx Power
of one ODU, you should change Tx Power of both ODU same
time.
Equipment IP Address
Configuration
Configuring Q Interface
Prerequisites The Web CIT system is logged on successfully.
Context Each IDU has two IP addresses in the same network segment, cor-
responding to Q interface (i.e. network interface) and R interface
(i.e. radio interface) respectively.
Steps 1. Click Configuration > TCP/IP Config > Q Interface in the
left menu bar, as shown in Figure 31.
Configuring R Interface
Prerequisites The Web CIT system is logged on successfully.
Context Each IDU has two IP addresses in the same network segment, cor-
responding to Q interface (i.e. network interface) and R interface
(i.e. radio interface) respectively.
Steps 1. Click Configuration > TCP/IP Config > Radio Interface in
the left menu bar, as shown in Figure 33.
2. Tick the Enabled check box in the OSPF area on the right part
of the configuration interface.
3. Click the Apply button to complete the configuration of dy-
namic routing.
END OF STEPS
Setting NE Time
Prerequisites The Web CIT system is logged on successfully.
Context To set the correct time and time zone for an NE, perform the fol-
lowing steps.
Steps 1. Click Configuration > System > Time Management in the
left menu bar, as shown in Figure 42.
4. When the priority scheme is 802.1p, user can set the 802.1p-
based priority, as shown in Figure 48.
5. When the priority scheme is DSCP, user can set the DSCP pri-
ority, as shown in Figure 49.
END OF STEPS
Note:
To implement handover between different switch level, IDU must
be rebooted. For both Mode 2(L3) and Mode 1(L2), the IP ad-
dress of the PC where user performs management operations and
IP address of the directly connected IDU must be in the same net-
work segment. For Mode 2(L3), the two IDUs of the two one-hop
equipments must be in different network segments respectively.
Steps 1. In the left menu, click Configuration > Switch Level >
Switch Level to select the switch level, and click Apply, as
shown in Figure 50.
2. Reboot IDU and log in the Web CIT system again. After doing
that, the switch level configuration takes effect.
END OF STEPS
Upgrading System
Prerequisites The Web CIT system is logged on successfully.
Steps 1. In the left menu, click Maintenance > System > System
Software, and click Apply, as shown in Figure 51.
END OF STEPS
END OF STEPS
Service Configuration
Table of Contents
Configuring Main Service ....................................................53
Configuring External Alarm Function ....................................59
Configuring E1 Service
Prerequisites The Web CIT system is logged on successfully.
Context To enable the E1 service, perform the following steps.
Steps 1. Click Configuration > MUX Interface > Tributary in the left
menu bar, as shown in Figure 55.
ETH Service
END OF STEPS
2. In the MAC Address Aging area, select the aging mode from
the Aging Mode drop-down list box, as shown in Figure 63.
and select the manual control mode from the Manual Control
drop-down list box, as shown in Figure 69 and Figure 70.
Configuration Check
Table of Contents
Checking NE Configuration..................................................63
Checking System Availability ...............................................64
Checking Radio Port ...........................................................64
Checking Trasceiving Power ................................................66
Checking Ethernet Transceiver Packages ...............................68
Checking NE Configuration
Prerequisites The system configuration is completed through Web CIT.
Context The checking items include: system status, protection mode, soft-
ware version, TCP/IP configuration, ODU and power control con-
figuration.
Steps 1. Check the system status.
Choose Quick Setup > Quick Config > System, and check
the name, location, contact information, system time, E1 used
capacity, bandwidth and modulation mode.
2. Check the protection mode.
Choose Quick Setup > Quick Config > Protection, and
check the protection type and protection mode.
3. Check the software version.
Choose Quick Setup > Quick Config > Software, and check
the software version.
4. Check TCP/IP configuration.
Choose Quick Setup > Quick Config > TCP/IP, and check
NE IP address/mask, radio IP address/mask and remote NE IP
address.
5. Check the ODU status.
Choose Quick Setup > Quick Config > ODU, and check the
receiving/transmitting frequency, the receiving/transmitting
power and the transmitting frequency step.
6. Check the system power control.
Choose Quick Setup > Quick Config > TPC, and check the
power control mode, maximum ATPC transmitting power, ATPC
lower threshold, higher ATPC threshold.
END OF STEPS
END OF STEPS
END OF STEPS
Checking Ethernet
Transceiver Packages
Prerequisites The Web CIT system is logged on successfully.
Context Data statistics for Ethernet port involves four common ports of Eth-
ernet and one wireless Ethernet port. The statistics is displayed
in three modes: current 15 minutes, history 15 minutes, and cur-
rent 24 hours. In each display mode, the statistics is displayed
according to the five ports respectively.
Note:
For port utilization, only the statistic data of wireless Ethernet port
is provided. Because the volume of statistic data of Ethernet is
very large, the display mode of history 15 minutes only provides
statistic data of one day.
Steps 1. In the left menu, click Performance > Ethernet > Current,
as shown in Figure 78.
END OF STEPS
CIT
- Craft Interface Terminal
IDU
- Indoor Unit
ODU
- Outdoor Unit
SNMP
- Simple Network Management Protocol
VLAN
- Virtual Local Area Network