Instrument and

Compressor Control Systems


Altronic Instrumentation and Compressor Control Products

CONTENTS
Altronic Instrumentation and Compressor Control Overview
An introduction to Altronic’s design and application philosophy............................................................................. 3

Annunciators and Compressor Controllers


DD-NT Digital Safety Shutdown Annunciator........................................................................................................ 4
DD-40NTV Digital Annunciator with Advanced Features and Communications......................................................... 4
DD-1500 System for Safety Shutdown, Monitoring, Compressor Control and Communication................................... 5
DE-3000 System for Safety Shutdown, Monitoring, Compressor Control and Communication................................6–7
Altronic Exacta21 System for Comprehensive Engine/Compressor Automation......................................................8–9

Speed/Hours/Timing Indication Instrumentation


ECMD Emissions Compliance Monitoring and Datalogging System....................................................................... 10
DTHO1201/3201 Universal Speed Monitoring Instruments with Hourmeter and Overspeed................................... 11
DH-100A Digital Hourmeter.............................................................................................................................. 11
DSG-1201 Digital Setpoint Gauge — Speed...................................................................................................... 11
DSG-1401 Digital Setpoint Gauge — Ignition Timing.......................................................................................... 11
DO-3300/3300A Digital Speed Switches........................................................................................................... 11

Temperature/Pressure/Vibration Instrumentation
45PHL Pressure Switch-Gauge with Low/High Setpoints..................................................................................... 12
DPS-1591 Digital Pressure Gauge with Dual Setpoints........................................................................................ 12
DPYH-1300U Series Universal Temperature Sensing Instruments (Pyrometers)..................................................... 13
DSG-1611DUPS/1682DUPS/1692DUS Digital/Bar-Graph Setpoint Gauges for Pressure, Temperature, Vibration
and other Variables........................................................................................................................................... 13
DPY-4118U-A Digital Pyrometer........................................................................................................................ 14
DPYH-4300U Series Universal Temperature Sensing Instruments (Pyrometers)..................................................... 14
DSM-43900DUS-Series Digital Setpoint Monitors for Temperatures..................................................................... 15
DSM-4600DUS-Series Digital Setpoint Monitors for Pressure, Temperature, and other Analog Parameters.............. 15
ETM-40 Universal Temperature Monitor/Scanner with ModBus Communications................................................... 16
DET-1600/1620 Detonation Sensing Monitor..................................................................................................... 17
VSM Vibration Sensing Monitor......................................................................................................................... 18

End Devices
GSV-Series Gas Shutoff Valve............................................................................................................................ 19
LLS-Series Liquid Level Switch......................................................................................................................... 19

Instrument Accessories
Pickups, Transducers, Barriers, Enclosures......................................................................................................... 20

Altronic Controls, Inc.


Facilities, Capabilities, and Typical Control Panels........................................................................................ 21–23

Note: Please see Altronic Ignition Systems and Engine Controls catalogs for information on Altronic air/fuel ratio, fuel
control and speed control products.

All rights reserved


© ALTRONIC, LLC 2012 2
ADI-C 3-12
Altronic Instrumention and Application Philosophy

AItronic has been a preferred provider of high-quality, digital instrumentation, control,


and safety/­shutdown systems to the energy p
­ roducing industries for more than 25
years. From design and field testing, to integrated manufact­uring and internal quality
control systems, Altronic instruments and controls are engineered and constructed
to meet the industry demand for reliable service and performance on an around-the-
clock basis.

To address the rigorous operational and environmental requirements of the oil and
gas marketplace, Altronic designs and builds all of its products to insure extended,
trouble-free service under the most demanding conditions. Dedicated devices, built
and continually updated to meet specific application requirements such as annuncia-
tion, temperature and pressure monitoring, and speed sensing, offer users a number
of oper­ational advantages over competitive products and approaches including:

Hardware availability and continuity Support


Unlike many products produced for In addition to direct support from the
less-demanding industrial applications, factory, Altronic products are supported
including PLCs (programmable logic by a worldwide network of factory-trained
controllers), Altronic instruments are built Distributor service technicians. Easily
and supported over extended periods of accessible documentation is available to
time. For operators of critical equipment, the end user via altronicinc.com. Altronic
including compressors, generators, and instrument products are also supported
pumps, this assures access to spare parts in most cases by both informed controls
and/or backward­compatible enhanced technicians and operations personnel.
designs well into the future.
Dedication to the oil and gas industry
Designed for difficult and hazardous Altronic has spent the last twenty-five
environments years designing and refining instrument
Service in the oil and gas industries products specifically to meet the needs
brings with it a unique set of challenges, of the oil and gas industries. Unlike many
including excessive temperature, other instrument manufacturers, Altronic
exposure to RFI (radio frequency does not attempt to bring products
interference), and corrosive elements manufactured for industrial applications
(moisture, salt spray, and H2S-hydrogen into demanding oilfield service. As a CERTIFIED FOR USE IN
HAZARDOUS LOCATIONS
sulfide gas). Altronic products are built to result, Altronic instrument products have NOTE: Most, but not all, Altronic digital
instruments and controls in this catalog
survive in these conditions and to provide earned a reputation within the petroleum are CSA certified and compliant with the
appropriate CE/ATEX regulations. Check
extended, trouble-free service. Most industries for reliability and serviceability each product listing for certification and
hazardous area classification.
Altronic products are certified by the that is unmatched by its peers.
Canadian Standards Association as safe
for use in hazardous areas.

All rights reserved


© ALTRONIC, LLC 2012 3
ADI-C 3-12
Annunciators and Compressor Controls

DD-NT Digital Annuciator Systems DD-40NTV Series Digital Annunciator supply 691200-3 include readout of igni-
Patented DD-NT annunciator systems, with Advanced Features and tion, DC and internal battery voltages and
available in 20- and 40­-point mod- Communications US Patent 6,738,244 pre-lube and post-lube functions.
els, continuously monitor and protect The latest version of the industry-stan- A sealed membrane keypad and powder-
gas compressors, dard annunciator, the DD-40NTV series coated aluminum enclosure ensure
generators, pumps, monitors up to 40 electrical contacts that maximum reliability in harsh and hazard-
and other types of represent limits on ous environments. The DD-40NTV series
critical equipment. critical operating annunciators are certified by Canadian
These solid-state parameters such as Standards Association (CSA) as suitable
systems scan the engine or process for use in Class I, Division 2, Groups C
connected electrical con- pressures, temper- and D areas.
tacts which may represent atures, levels, etc.
„„ Monitors up to 40 electrical
limits on functions such CERTIFIED Upon detection of
CLASS 1, DIV. 1 & 2,
contacts for fault
as pressure, temperature, GROUP D a fault from one of the moni-
„„ On-board tachometer/hourmeter/
level, etc. The first-out cause of fault tored points, the annunciator CERTIFIED overspeed
CLASS 1, DIV. 2,
is displayed and remembered to aid in displays the corresponding GROUPS C & D „„ Displays ignition, DC, and battery
troubleshooting and to minimize down- 2-digit fault code for that point and gen- voltages
time. Designed to replace mechanical erates an output signal (typically to close „„ User adjustable pre/post-lube
indicators, relays, and pneumatic flags, a fuel valve and ground the ignition). „„ Supports RS-232/485 ModBus RTU
the CSA-certified DD-NT systems indicate communications
The DD-40NTV annunciator offers integral
operating mode and specific cause of
tachometer and hourmeter functions as
fault. They can monitor for out-of-bounds
well as overspeed protection adjustable NOTE: The DD-40NTV annunciator may also
conditions prior to startup, and have a
from the front keypad. Other features be used with the 691200-1 Power Supply to
built-in class B bypass timer and on- emulate the function of the DD-40NTS system
carried over from the prior DD-NTS series
board sensor test capability.
include four configuration templates (two
„„ Front panel-mounted class B start-up of these simulate the older DD-NT 20 and
timer adjustment switch 40 point models), two programmed timers
„„ Redundant, long-life, field- for class B points and a programmable
replaceable lithium batteries
delay of the second shutdown output after
„„ Transient-protected sensor inputs can
fault detection. The annunciator contin-
withstand momentary contact with
ignition primary leads or other high- ues logic operation on the internal battery
voltage sources in the event the power becomes discon-
„„ One common logic unit (display) nected or fails.
connects to either a Division 1 or
Division 2 power supply The DD-40NTV series also provides a
„„ Quick-disconnect terminal strip ModBus compatible, RS-232/RS-485
assemblies for sensor and power serial communications interface for con-
connections
nection to an RTU or PLC. New features
in the NTV version when used with power

All rights reserved


© ALTRONIC, LLC 2012 4
ADI-C 3-12
Annunciators and Compressor Controls

DE-1500 Universal Process Loop thermocouple or temperature transducer, communications protocol. A full­-featured
Controller with one of the DE-1500 PID outputs PC-based monitoring and control software
The Altronic DE-1500 Universal Process controlling a compressor fin-fan or other package is included with each DE-1500
Loop Controller is designed to control cooling device. The DE-1500 can also system.
virtually any engine, compressor, or send a speed
„„ Universal, two-loop controller designed
industrial process. Using both digital setpoint to a
to control and monitor engines,
and analog inputs for parameters such as suitable governor compressors, or industrial processes
speed, temperature, and pressure, this or control device „„ Cost-effective alternative to
configurable control can use one or both (such as the pneumatic suction controllers and
of its independent PID outputs to dynami- Altronic GOV10) expensive electronic controls

cally adjust a process(es) to maintain a for RPM control „„ 2 independent PID loops, 2 pulsed
outputs, and 8 digital outputs
specified setpoint. of the compressor prime
available for control functions
mover (engine or electric
Among the many applications for the „„ Directly accepts 4 digital and 8
motor). CERTIFIED
analog inputs (thermocouple and/or
CLASS 1, DIV. 2,
DE-1500 is as a suction controller for GROUPS C & D
0-5VDC transducers plus 1 RPM)
compressors in gas production or process- For operators seeking inde-
„„ ModBus RTU communications
ing service. Continuously monitoring the pendent control and safety shutdown standard
compressor suction pressure, the DE- protection, the DE-1500 can be easily „„ Easily configurable via included
1500 can be con­figured to throttle the combined with other Altronic products, WindowsTM-based terminal program
gas pressure control valve either directly including the DD-40NTS digital annuncia-
or via an interposing I/P converter. Simi- tor. To facilitate integration with supervi-
larly, critical temperatures could also be sory monitor­ing and control systems, the
monitored and maintained via an input DE­-1500 fully supports the ModBus RTU

DE-1500 retrofit of an existing


pneumatic pressure controller

4-20mA Signal

Pressure Input

Supply Air PACT

Control Valve

All rights reserved


© ALTRONIC, LLC 2012 5
ADI-C 3-12
Annunciators and Compressor Controls
DE-3000 Series Configurable Safety the need for any knowledge of ladder-logic
Shutdown and Control System with or other functional programming languag-
Graphing Capabilities es. ModBus-RTU communications are
The DE-3000 Configurable Safety fully supported for remote monitoring and/
Shutdown and Control System uses or control applications.
state-of-the-art microcontrollers and
System operating and application perfor-
surface-mount PCB assembly technology
mance information such as engine speed,
to provide users of compressors and other
monitored pressures and temperatures,
critical rotating equipment with a sophis-
and the nature of detected alarms and
ticated, yet reliable, means of protecting
shutdowns is available via a robust, sixteen
and controlling both the prime mover and
position, sealed-membrane keypad and
the load machine (compressor, pump,
128 x 64-pixel graphics display with multi-
etc.). Incorporating an “intelligent” add-
color backlighting. The backlight colors will
on board system, the DE-3000 system is
change according to the condition of the
fully scalable, allowing users to incorpo-
engine. The backlight colors are as follows
rate a single control system technology
for the given engine conditions:
across a wide range of applications.
RED: FAULT / STOP “New” Display
The base DE-3000 configuration offers
GREEN: RUNNING
a number of digital and analog outputs,
YELLOW: TIMERS ACTIVE CERTIFIED
as well as thirty (30) inputs that can be
PURPLE: TEST MODE CLASS 1, DIV. 2,
GROUPS C & D
individually configured for use with switch
contacts, thermocouples, or analog trans- The display also has a graphing feature
ducers. Using one of two different add-on instead of a bar graph. Each analog chan-
terminal boards, medium and high-spec nel (including speed) may be viewed. The
applications can be accommodated with graphing screen is updated every minute
up to sixty (60) configurable inputs, twenty (which allows the user to see 90 minutes
(20) digital outputs, and four (4) user- of past data on the screen) and shows the
adjustable, analog PID outputs. This ap- most recent data to the left of the screen.
proach also allows for a single control sys- The last data is shown on the far right
tem to be used across a fleet of units, thus hand side of the screen. The graphing fea-
simplifying maintenance and part stocking ture will allow the user to view trending on
requirements, along with system training the panel. System configuration informa-
requirements for operating personnel. tion is stored in non-volatile memory as
are the associated system datalogs.
Ease of system setup and configuration
sets the DE-3000 apart from other PLC-
“Classic” Display
style or competitive controllers. USB-
based connectivity to the device and an
intuitive, WindowsTM-based terminal pro-
gram for system configuration eliminates

All rights reserved


© ALTRONIC, LLC 2012 6
ADI-C 3-12
Annunciators and Compressor Controls

„„ Specifically designed to protect, “New” Display Screens


monitor and control critical rotating Home Digital Graphing
machinery, such as engine or 100.0
motor-driven compressors, pumps
and generators operating in harsh/
RUNNING RUNNING
hazardous areas STATUS RUNNING SELECT CHANNEL FOR
SPEED 1000 RPM GRAPHING MODE> 01
„„ Completely scalable and expandable SUCTION 102.3 PSIA 0
DISCHARGE 300 PSIG
system allowing for use across a wide CH02 55.1 PSIA
range of applications
„„ Automatically and continuously optimizes “Classic” Display Screens
compressor efficiency and throughput via Home Digital Bar Graph
speed and capacity control STATUS RUNNING SUCTION 22 PSIA
SPEED 1000 RPM DISCHRG 100 PSIG
„„ Integral auto-start functionality for SUCTION 102.3 PSIA FILTR 10 PSIA
unmanned or highly-cyclic applications DISCHARGE 200 PSIG BOP 110 PSIG
„„ All system inputs can be individually
configured for:
— Sensor Type: Analog transducer
input, thermocouple input (type J
or K) or digital (switch) input
— Sensor Class: Class A, B or C logic
— Digital Input Sensor Run/Fault
Status: N.O. or N.C.
„„ Large color-changing display offers
optimal annunciation of all functions,
including on-screen graphing
„„ ModBus-RTU compatible, and easily
configurable via included WindowsTM-
based terminal program

1ST 2ND FREQUENCY ANALOG


DISPLAY DISCRETE ANALOG DIGITAL
TERMINAL BD. TERMINAL BD. (SPEED) P.I.D.
MODULE INPUTS INPUTS OUTPUTS
PART NO. PART NO. INPUTS OUTPUTS
DE-3000 691171-1 — 30 configurable 1 12 2
DE-3000 691171-1 691175-2 45 configurable 2 16 4
DE-3000 691171-1 691171-2 60 configurable 2 20 4
NOTE: All inputs are configurable for discrete, analog or thermocouple input.

All rights reserved


© ALTRONIC, LLC 2012 7
ADI-C 3-12
Annunciators and Compressor Controls

Exacta21 System for Comprehensive transducers, Type J and K thermocouples, intervals prior to shutdown and can also
switched digital inputs, RTDs, and resis- store up to 40 separate shutdowns.
Engine/Compressor Automation
tive inputs are all compatible with the Communications
The Exacta21 is an “all-in-one” prepro-
system, giving the user complete applica- Designed for operation in a “serial
grammed system, dedicated to monitor-
ing, controlling, tion flexibility. environment”, the Exacta21 has built-in
and optimizing Shutdowns, Annunciation & Monitoring RS232 and RS485/422 ports for commu-
gas compressors The first—and most critical—responsibil- nication. External connections to super-
and associated ity of the system is to ensure the safe visory control or communication systems
site equipment. operation of the engine and compressor. (including station controls and SCADA
It is focused on An unlimited number of shutdown and systems) are accomplished via ModBus
comprehensive, alarm setpoints can be added to any RTU protocol.
high spec control channel, including the normal high and Programming
and monitoring low values plus differentials, “calculated Combining the flexibility of a PLC with
applications (often shutdowns”, time delayed shutdown the programming ease of a dedicated,
managed by PLCs points, and for out-of-range data values. purpose-built controller, the Exacta21
or other high-end con- The “First-out-fault” is annunciated in uses object-oriented programming to con-
trols) where its processing the display, and the preconfigured actions figure the system for operation. Capable
CERTIFIED
CLASS 1, DIV. 2, power and large number (shutdown and/or alarm) are executed of addressing both simple and complex
GROUPS C & D
of inputs and outputs are automatically to maintain the safety of control protocols, virtually all compres-
required. The Exacta21 differs from most the unit and personnel. sor control functions are capable of
PLCs however, in that it accommodates automation, including shutdown, alarm,
Start/Stop and Capacity Control
configuration revi­sions directly from the pre-tube, post-lube, start/stop, and load
Each Exacta21 system can perform full
keypad or via a standard PC, and the ap- management.
startup, load, unload, and shutdown func-
plication core (where the design continu-
tions, including pre-lube, purge, crank, Hazardous Area Approval
ity is governed by a manufacturer and not
warm-up, and post-lube. Full capacity Unlike many industrial PLC controls, the
an individual programmer) of the configu-
control (load) is accomplished by adjust- Exacta21 system is CSA certified for use
ration programs are the same from unit
ing up to 15 PID control loops, making in Class I, Division 2, Group C and D
to unit. The Exacta21 offers significant
the system suitable for both reciprocating areas. This eliminates the need for ex-
enhancements over prior models, including
and screw compressors. pensive local approvals, explosion-proof
surface-mount construction and conformal
Data Capture enclosures, and maintenance-intensive
coating of electronic components, reduced
To aid in long-term monitoring and analy- purging systems.
board size, DIN rail mounting, and a fully
integrated power supply. sis, the Exacta21 Controller automatically
NOTE: Although the Altronic Exacta21 System
records all of the monitored temperature,
Input/Output Capacity and Flexibility replaces the Exacta Series XI Monitoring
pressures, and other analog inputs at and Control System, parts and service for the
Using “Smart” Analog and Discrete Input/
regular intervals, storing up to 1,400 Series XI will continue to be available
Output Boards, the Exacta21 is capable
records in its memory. For enhanced
of monitoring up to 192 signals including
troubleshooting, the Exacta21 records
temperature, pressure, level, and others.
40 records of data, taken at one second
4-20mA-based inputs, as well as 0-5VDC

All rights reserved


© ALTRONIC, LLC 2012 8
ADI-C 3-12
Annunciators and Compressor Controls

Why an Exacta21? „„ Application stability — both the


hardware and embedded application
The innovative Exacta21 System offers
are based on a repeatable engineering
users a stable hardware and application and manufacturing standard
platform that will be manufactured and „„ User and field configurable (password
supported in the long term, and a highly protected) with no knowledge of
expandable and flexible monitoring and ladder logic or other programming
languages required
control platform capable of servicing even
„„ Long-term access to field and factory-
the most demanding, control-intensive
based technical support
applications. While protected by a tiered
„„ Robust hardware specifically designed
security system insuring controlled for use in hazardous areas
access, this approach also gives the user „„ Upgrade and service parts available
the ability to make operational changes from Altronic Distributors worldwide
from the keypad without additional „„ On-board security and tracking for
hardware and/or software, and without a improved revision and parameter
adjustment control
detailed knowledge of ladder logic. Taken
together, these capabilities offer flexibil-
ity, serviceability, and expandability for
virtually any gas compressor application.

Control Panel Software


Accessible from a standard PC running HyperTerminalTM or other inexpensive com-
munication software, it displays a combination of analog inputs, shutdowns, alarms,
recorded history and events monitored by the Exacta21 System.

AGA 3 and AGA 8 Flow Calculations


The Altronic Exacta21 is capable of performing both AGA 3 and AGA 8 gas flow calcu-
lations, with up to five calculations performed simultaneously.

Program Revision Tracking


The Program Revision Tracking System is available as an option and offers the ability
to automatically record any changes to system configuration. This is an ideal tool for
configuration monitoring and accountability.

Data Capture and Trending


Using the data logging system within the Exacta21, the system is capable of download-
ing the monitored data to a PC-based spreadsheet and statistical analysis software
package for trending and performance analysis.

Optional Graphical User Interface


Remote monitoring and control of the Exacta21 system can be enhanced through the
addition of a graphical user interface (GUI), such as the package shown here.

All rights reserved


© ALTRONIC, LLC 2012 9
ADI-C 3-12
Emissions Monitoring

ECMD-100 The Altronic ECMD-100 series of emis-


Emissions Compliance Monitoring sions compliance monitoring and datalog-
and Datalogging Systems ging devices are designed to cost-effec-
„„ Full-featured, cost-effective engine tively assist operators of reciprocating
emissions monitoring system engines facing strict guidelines specific to
exhaust emissions monitoring and record-
„„ Monitors critical parameters associa-
ing. Built around a proven and stable plat-
ted with environmental regulations,
form of Altronic and optional third-party
including RICE-NESHAP
products, the ECMD systems offer users
— Temperatures
flexible access to the core monitoring
— Pressures
hardware in either a pre-packaged aux-
— Additional discrete and analog
iliary panel or as individual components
inputs
to be installed in new or existing engine
„„ Records up to one-hundred (100) control panels. sands of additional normal and fault
time and date stamped datalogs
datalogs for local and remote access,
accessible via USB interface All RICE-NESHAP requirements for moni- trending, and compliance reporting (120
— Data captured continuously and toring of critical catalyst-related tempera- days). Each ECMD system also supports
recorded in fifteen minute inter-
tures and pressures are monitored and full Modbus communications compat-
vals in accordance with current
RICE-NESHAP regulations recorded by the ECMD system. The ECMD ibility for integration with local HMI/moni-
system’s flexible input structure ensures toring systems and/or SCADA/telemetry
— An optional “Enhanced” version
allows for thousands of fifteen that the device will remain compatible devices. Ethernet (Modbus TCP, HTTP
minute datalogs to be recorded with future requirements which may call and FTP) connectivity is available in the
and accessed via an on-board for additional sensor technologies such as Enhanced System.
CompactFlash© Card
O2 and NOx monitoring. Its on-board alarm
„„ Available in a variety of configurations and shutdown output switches can also be
to suit specific application require- configured to insure that any out of com-
ments and budgets pliance operation associated with any of
— Both Standard and Enhanced the parameters alerts the operator locally
versions are available as loose or remotely, and/or shuts the monitored
components or pre-packaged in
equipment down automatically.
a NEMA 4X auxiliary panel for
simple installation on an appli-
cation where field modification Standard ECMD systems feature on-board
of the existing control panel is datalogging capable of retaining up to
not a viable option
one-hundred time/date-stamped records.
„„ Easily interfaced to SCADA or remote All monitored data is collected on 15
communication systems minute intervals (per RICE-NESHAP),
„„ For use in Class I, Division 2, Group with additional datalogs generated upon
C and D hazardous operating areas setpoint excursions (faults). Enhanced
ECMD systems record and retain thou-

All rights reserved


© ALTRONIC, LLC 2012 10
ADI-C 3-12
Speed/Hours/Timing Indication Instrumentation

DTHO-1201/3201 Universal netic pickups. The DH-100A is designed signal can be derived from the #1 cylinder
Speed Monitoring Instruments with to with­stand vibration and to give extend- ignition coil of a CD ignition system or a
Hourmeter and Overspeed ed service in hazardous and demanding magnetic pickup. Four individual setpoints
These digital tachometers are designed environments, eliminating the problems and output switches can be configured for
for universal use. They are high-quality, associated with mechanical devices. use in automation projects.
microprocessor-based devices that can Power consump- DSG-1401 Digital Setpoint Gauge
be powered from either a C.D. ignition tion is negligible Indicates engine ignition timing. Two
“shutdown lead” or a magnetic pickup, for (microamps) and timing setpoints/outputs can be config-
use on natural gas engines and other critical the device can be ured, with outputs three and four used to
rotating equipment. Both models include applied to virtu- provide rotation-confirm and fire-confirm
over­speed trip and hourmeter func­tions. ally any process. for engine automation projects.
Switches on the back of the unit
DTHO-1201 features a weather resistant DO-3300/D0-3300A
allow the hour count to be preset to
4-1/2" round case which Digital Speed Switches
any number, or reset to zero. When
can be mounted in an D0-3300 Series Digital Speed Switches
the power is discon­nected, the accumu-
industry-standard operate from CD ignition systems with
lated count is retained and the readout
cutout. It replaces no other signal or
can be obtained by depressing the button
the DT/DTH/DTO/ power source re-
on the front of the unit.
DTHO-1200-series quired. Applicable
tachometer instruments. DSG-1201/1401 Digital Setpoint to all spark-ignited
DTHO-3201 is packaged in Gauges for Speed & Timing Indication engines, the trip
a 4.19" X 5.00" Lexan case. The DSG-series instruments are built RPM is set in 10
It replaces DTO-1010, upon a common, microprocessor-based RPM increments by three rotary
DT/DTH/DTO-3200 platform and share a common set of switches on the front face of the
and the PT/PTH/PTO/ installation and op- device. Two models cover most
PTHO-2100 series erationonal features. speed-related applications.
devices. These high-level, DO-3300
DC-powered instru- General-purpose speed switch with an
These highly accurate devices
ments feature a input voltage range of 100-400VDC.
are simple to set up. No calibration is
unique digital/ana- Isolated output switch turns on above
required. Either device can be configured
log display, simple setpoint, off below setpoint.
to monitor engine RPM or higher speeds
user configuration via a sealed
of interest, including turbocharger RPM. DO-3300A
membrane keypad, multiple
CERTIFIED

An advanced filtering algorithm assures a


CLASS 1
DIV. 1 & 2 Special overspeed trip model designed for
setpoints, Form C (N/O or N/C) GROUP D

stable speed readout even during periods engines using ignition systems of 200VDC
output switches, are housed in a durable
of speed input fluctuation. primary voltage or lower. Can directly short
4-1/2" round Lexan enclosure, and have
DH-100A Digital Hourmeter the ignition system or trip safety relay
optional 4-20mA outputs.
This solid-state digital hourmeter operates switch or pneumatic valve.
DSG-1201 Digital Setpoint Gauge
directly from CD ignition systems, 8 to
Designed to provide an accurate indication
440VAC or VDC, or intrinsically-safe mag-
of speed. The required input frequency

All rights reserved


© ALTRONIC, LLC 2012 11
ADI-C 3-12
Temperature/Pressure/Vibration Instrumentation

45PHL Pressure Switch-Gauge 45PHL Pressure Ranges the application of outside power. In addi-
with Low/High Setpoints Gauge Range Part Number
tion to power, display, and output switch
The Altronic 45PHL-series pres­sure -30" Hg to 30 psi 45PHL-30V30 flexibility, the DPS­1591 DP incorporates
switch-gauges are the standard for me- -30" Hg to 100 psi 45PHL-30V100 a number of features designed to enable
chanical pressure gauges with low/high 0-30 psi 45PHL-30 its use in a wide range of applications and
switch contacts. 0-60 psi 45PHL-60 environments, including integral pres-
0-100 psi 45PHL-100 sure transducer built from high-quality
Incorporating the innovative “direct­ 0-160 psi 45PHL-160 stainless steel and incorporating a media-
drive” pressure-sensing technology devel- 0-200 psi 45PHL-200 isolated sensor with no internal o-rings,
oped and used for 0-300 psi 45PHL-300 silicone oil or welds. Featuring a large
precision pressure 0-500 psi 45PHL-500 digital and bar­graph display, this unique
test instrumenta- 0-600 psi 45PHL-600 instru­ment provides the actual monitored
tion, the 45PHL 0-1000 psi 45PHL-1000
value and an indication of that reading as
utilizes a special, 0-1500 psi 45PHL-1500
a percent of span between two selected
helically wound 0-2000 psi 45PHL-2000
points, as well as a reference to direction
coil of Inconel to 0-3000 psi 45PHL-3000
and amplitude of a rapid change in read-
0-5000 psi 45PHL-5000
properly determine and display the moni- ing. An adjustable software filter stabilizes
tored pressure. This approach eliminates readings where the monitored pressure
the internal gears and linkages used in DPS-1591 Digital Pressure Gauge
is fluctuating. The gauge also stores the
traditional bourdon-tube based gauges, with Dual Setpoints
highest and lowest filtered readings to
as well as their associated inaccuracy The advanced, highly accurate (±.25% of
which it has been exposed.
and poor reliability. The 45PHL offers the span), DPS-1591 Digital Pressure Gauge

user extended service life, high accuracy is a single point pressure monitoring de- Two individually adjustable setpoints can
(±1%), and repeatable readings across vice, ideal for use be configured to trip on a low or high
the range of application and environmen- in monitoring pro- setpoint, as well as on a loss of loop. Both
tal conditions. Fifteen different pressure cess pressures. The output switches (one per setpoint) can be
ranges are available and are listed below. device is designed configured for normally open or normally
to accept power closed operation making the DPS-1591
To insure simple retrofit in the field, the from the same two ideal for gas compressor panel service.
45PHL is packaged in a 4-1/2" round lines used for the
weather-resistant case design­ed to fit into 4-20mA proportional current
DPS-1591 Pressure Ranges:
industry-standard panel cutouts. The switch loop output. For applications
setpoint arrangement features two color- Gauge Range Part Number
not requiring the current loop,
-14.7 to 50 psig DPS-1591DP-50
coded low/high setpoint adjustment knobs the unit can be externally
-14.7 to 100 psig DPS-1591DP-100
on the front of the gauge. The 316 stainless powered with DC-power. Utiliz-
-14.7 to 200 psig DPS-1591DP-200
steel connection stem is user-adjustable in ing either power source, unit operation
-15 to 500 psig DPS-1591DP-500
the field for bottom or back connection. For (and setpoint protection) is backed up by
-15 to 1000 psig DPS-1591DP-1000
maximum corrosion resistance, the device a very long life internal lithium 3.6-volt -15 to 2500 psig DPS-1591DP-2500
features stainless steel components, includ- battery. Extended stand-alone service -15 to 5000 psig DPS-1591DP-5000
ing all rivets and screws. (4+years) can also be achieved without -15 to 9999 psig DPS-1591DP-9999

All rights reserved


© ALTRONIC, LLC 2012 12
ADI-C 3-12
Temperature/Pressure/Vibration Instrumentation

DPYH-1300U Series Universal DPYH-1379U monitors nine points with indicates the units and annunciates an
Temperature Sensing Instruments point 0 protected by the first high-limit alarm by number and type.
(Pyrometers) setpoint, and points 1–8 protected by the
Two (one on the DSG-1682DUPS) solid-
These are solid-state instruments that second common high-limit setpoint. Both
state, form C (N.O. and N.C.) output
give a continuous temperature readout output switches are N.O.
switches can each be assigned high and
and have an alarm/
low setpoint values which are retained
shutdown capability at DSG Digital/Bar-Graph Setpoint Gauge
indefinitely. The precision nature of these
a user-adjusted tem- for Pressure, Temperature, Vibration
switches allows these gauges to be used
perature limit. These and Other Variables
as control devices.
“universal” 1-, 2- and These advanced gauges monitor, display
9-point temperature and protect either one or two process vari- DSG-1611DUPS The single-point
monitors are housed in durable, ables. The DSG-1611 is a universal one- model has both 4–20mA proportional out-
4-1/2" round Lexan cases, can point model. The DSG-1682DUPS and put and RS-485 serial communications.
CERTIFIED
be configured for readout in CLASS 1 DSG-1692DUS are two-point versions. It replaces all prior models of the DSG-
DIV. 1 & 2
degrees Farenheit or Celsius, GROUP D 1301 and 1601 and can be programmed
DSG gauges can be
use industry-standard type J or K ther- for both a low and high output for each of
connected to either
mocouples, and can operate from either the two output switches.
type J or K thermo-
12-48VDC or CD ignition input power. The
output switches integral to each unit are
couples, 0–5 volts or DSG-1682DUPS This dual-channel
0–25mA (scalable) in- gauge is a single-loop PID controller offer-
suitable for use with Altronic annunciators
put signals. In the DSG-1692, ing the following modes of operation:
or other specified devices.
this choice is independent
CERTIFIED „„ 4-20mA output loop vs. the channel 1
The single- and dual-point DPYH-1300U for each of the two monitored CLASS 1
input OR channel 2 – channel 1
DIV. 2
models can be used on applications rang- points. All three versions have GROUPS C & D (differential)
ing from engine oil and water temperatures a RS-485 serial port and ModBus com- „„ Direct or inverse PID output based
to catalytic converter and turbocharger in- munications with 5 selectable baud rates. on the input of channel 1 or in
a “mapping” mode that allows
let/outlet protection. The 9-point model is Power requirement is 12–36Vdc, 0.25A
the channel 1 PID setpoint to be
designed to use channels 1 through 8 for maximum. modified by the monitored input of
engine cylinder exhaust temperature read- channel 2.
DSG gauges feature a sealed membrane
ings with point 0 used for turbocharger or
keypad and a high-resolution digital read- DSG-1692DUS In the standard dual-
catalytic converter monitoring.
out/bar-graph display which indicates the point model, each channel is indepen-
DPYH-1301U monitors one point with a reading as a percent SUCTION dently assigned for type J or K ther-
high-limit setpoint; it has output switches of transducer span or mocouple, 0–5 volts or 0–25mA input
for both N.O. and N.C. operation span between high/ CH1 psi signals. This allows the device to be used
DIF 1002
psi
low setpoints, with a CH2 1214
psi for one temperature and one pressure or
DPYH-1392U monitors two points with
reference to direction DISCHARGE two of either type. In addition, the device
an individual high-limit setpoint for each
and amplitude of a can be set up with a differential setpoint
channel; it has output switches for both
rapid change in read- CH2 psi
between the two monitored points.
N.O. and N.C. operation 0% 100%
ing. The display also CH1 212 psi

All rights reserved


© ALTRONIC, LLC 2012 13
ADI-C 3-12
Temperature/Pressure/Vibration Instrumentation

DPY-4118U-A Digital Pyrometer DPYH-4300U Digital Pyrometers with a common output switch. A typical ap-
The intrinsically-safe, internally ­powered Alarm Switch plication would use the device to monitor
DPY 4118U-A digital pyrometer is a cost­ These electronic instruments monitor individual engine cylinder temperatures
effective, accurate, and reliable alterna- temperatures using industry-standard type (up to 16) with a common shutdown on
tive to traditional mechanical switch- J or K thermocouples. Models are avail- the turbocharger inlet or post-catalyst
based temperature devices and analog able with 4, 6, 8, and 20-thermocouple temperatures.
meters/gauges. Offering 1° resolution and input channels. Readout can be config- Setpoints and normally-open output
1% ±3 degrees accuracy, these precision ured for degrees C. or F, and the device switches are integral to all DPYH-­4300U
devices can monitor up to 18 points of in- can be powered from either 12-48VDC series systems, enabling their use in the
terest using industry-standard type J or K or a CD ignition. Most models (with the temperature monitoring and protection
thermocouples. The device is powered exception of the DPYH-4320U ­series) role in conjunction with a digital annunci­
by long-life lithium batteries with a feature user-selectable thermocouple type ator or DC-operated relay. All DPYH-
10-minute readout period each time the (J or K) and a sealed membrane keypad. 4300U s­ eries instruments are housed in
front-panel membrane switch is activated. rugged, anodized aluminum enclosures for
Indication of both open thermo­couples DPYH-4354U monitors up to 4 separate maximum surviva­bility and reliability in
and low battery is given in the display inputs against a common setpoint. All
difficult operating environments.
to maintain trouble­-free service. The faults trip a common output switch.
DPY-4118U-A is housed in a gasketed,
powder-coated, alum­inum enclosure with DPYH-4394U accepts up to 4 sepa-
stainless steel hardware, making it ideal rate inputs, each monitored against

for oilfield service or other corrosive and an individually-adjustable setpoint. An

environmental­ly-demanding applications. individual output switch is provided for


each setpoint.

DPYH-4396U accepts up to 6 sepa-


rate inputs, each monitored against
an individually-adjustable setpoint. An
individual output switch is provided for
each setpoint.

CERTIFIED
DPYH-4398U accepts up to 8 sepa- CLASS 1
DIV 1 & 2
rate inputs, each monitored against GROUP D

an individually-adjustable setpoint. An
individual output switch is provided for
each setpoint.

CERTIFIED
CLASS 1 DPYH-4320U monitors up to 20
GROUP D
Intrinsically Safe thermocouples with 4 of those thermo-
couple input points monitored against a
common setpoint. All setpoint faults trip

All rights reserved


© ALTRONIC, LLC 2012 14
ADI-C 3-12
Temperature/Pressure/Vibration Instrumentation

DSM-43900DUS-Series Digital calibration, and individual high/low DSM-4600DUS an ideal “front end” data
Setpoint Monitors for Temperature setpoint values are accessible and adjust- collection device for use with supervisory
Designed specifically for monitoring able from the front of the device. Fault controllers such as the Altronic DE-Series
temperatures on en- information by sequence of occurrence systems and remote
gines, compressors, is available on both the unit display and monitoring (SCADA)
and other critical via the RS-485 serial port. ModBus RTU systems.
applications, these allows for remote communications of the
All models are
devices operate on monitored conditions.
12–30VDC powered,
12-30VDC power
DSM devices are housed in a gasketed, and feature a sealed
and use standard
powder-coated aluminum enclosure and membrane keypad as well as
type J or K thermocouples as
assembled using stainless steel hardware, a large, backlit LCD display
inputs. All DSM-43900DUS CERTIFIED CERTIFIED
CLASS 1 making them ideal for use in oilfield or for both the channel number CLASS 1
units feature ModBus RTU DIV. 1 & 2 DIV. 1 & 2
GROUPS C & D other environmentally-challenging ap- and the value of the monitored GROUPS C & D
communications via an inte-
plications. variable.
gral RS-485 output.
„„ DSM-43908DUS accepts up to 8
All DSM devices are housed in gasketed,
Each of the three “universal” devices type J or K thermocouple inputs
powder-coated aluminum enclosures and
has four individual setpoints (two high NOTE: This device can be configured
assembled using stainless steel hardware,
and two low) per channel and two output to simulate the popular DSM-4388DUS
model which it replaces. In this mode, making them ideal for oilfield or other
switches. These units may be used in
there is one high and one low setpoint environmentally-challenging applications.
alarm/shutdown service or in any other
per channel, and one Form C, solid-state
configuration where the monitored points „„ DSM-4688DUS accepts up to eight
output switch.
(8) analog transducer inputs –
serve two functions. The monitoring ca-
„„ DSM-43916DUS accepts up to 16 typically for monitoring temperatures
pability of the device is further extended type J or K thermocouple inputs and pressures.
through the incorporation of a unique
„„ DSM-43924DUS accepts up to 24 „„ DSM-4689DUS accepts up to eight
grouping function whereby all tempera- type J or K thermocouple inputs (8) analog transducer inputs for
ture input channels can be sorted into a pressure, temperature, and other
single- or two-group configuration with in- process monitoring, plus a discrete
DSM-4600DUS-Series Digital
speed input (from a CD ignition
dividual group setpoints attached to each Setpoint Monitors for Pressures, system). An hourmeter is also
(two high, two low, and two differential). Temperatures, and other Analog provided in the unit.
Parameters
All models feature a sealed membrane
These monitors provide cost-effective
keypad and large, backlit alphanumeric
multipoint monitoring of pressures,
display for indication of the channel
temperatures, or other process variables
number, the value of the monitored
on compressor packages and generator
temperature, and a bar-graph showing the
applications in a serial communications
position of the monitored temperature
environment. The ability to monitor and
between the low and high setpoints. All
display up to eight analog transducer in-
setup details, including thermocouple
puts, combined with an integral RS-485
type (J or K), temperature units (F. or C.),
communications capability makes the

All rights reserved


© ALTRONIC, LLC 2012 15
ADI-C 3-12
Temperature/Pressure/Vibration Instrumentation

ETM-40US Universal Temperature range, setpoints, and other configuration


Monitor/Scanner with ModBus Com- data. All fault information (alarm and
munications shutdown) is available on the display in
The ETM-40US Universal Temperature the order of occurrence, which aids in
Monitor/Scanner is a microprocessor- determining the origin of the fault condi-
based instrument that monitors up to 40 tion. This same fault information, the
process temperatures. While primarily monitored temperature values, and the
designed for monitoring critical tempera- status of all channels, can be accessed
tures on reciprocating engines and com- via a PC, PLC, or other supervisory control
pressors, the availability of 10-36VDC or system using the ModBus RTU protocol
100-250VAC as input power options, the (RS-485). System configuration and
suitability for use with either type J or K setup (including custom point labeling)
thermocouples, and the wide variety of is simple and accomplished by accessing
input and output module options allows the keypad on the front of the device or
for the application of the ETM-40US to via the ETM-40US terminal software.
virtu­ally any industrial process requiring CERTIFIED
For maximum durability in demanding CLASS 1
state-of-the-art temperature protection. DIV. 2
operating environments, the ETM-40US GROUPS C & D

Each of the monitored points is arranged is housed in a gasketed, powder-coated, Normal Operating Screen
in one of seven temperature groups (see NEMA 4 steel enclosure and assembled
chart). This allows the user to group using stainless steel hardware.
similar points (such as engine cylinder
exhaust temperatures or turbocharger NOTE: The ETM-40US is designed to
Fault Screen
physically interchange with its predecessors,
outlet temperatures) which can be mea-
the ETS-24 and ETS­40 temperature scanners.
sured against a set of common alarm,
shutdown, and differential setpoints. Low
ETM-40US Group/Setpoint Matrix
and high setpoint monitoring for each
channel is also available. The ability to Group Channel Numbers Common Setpoints Individual Setpoints Outputs
choose between two sets of setpoints for L1, H1, D1 L1, H1 1
1 01-XX
L2, H2, D2 L2, H2 2
each channel and for each group, along
L1, H1, D1 L1, H1 1
with the flexibility in mapping of those 1A XX-16
L2, H2, D2 L2, H2 2
setpoints to individual outputs, enables L1, H1, D1 L1, H1 1
2 17-18
the ETM-40US to be used for both alarm L2, H2, D2 L2, H2 2

and shutdown annunciation. L1, H1, D1 L1, H1 1


3 19-20
L2, H2, D2 L2, H2 2

The backlit, alphanumeric LCD display L1, H1, D1 L1, H1 1


4 21-XX
L2, H2, D2 L2, H2 2
offers all of the setup and monitored
L1, H1, D1 L1, H1 1
5 XX-36
information. A front panel, sealed­ L2, H2, D2 L2, H2 2
membrane keypad provides easy selection L1, H1, D1 L1, H1 3
6 37-40
L2, H2, D2 L2, H2 4
and adjustment of the displayed units,
Note: Shading indicates default selection as the device is shipped.

All rights reserved


© ALTRONIC, LLC 2012 16
ADI-C 3-12
Temperature/Pressure/Vibration Instrumentation

DET-1600/1620 Detonation Sensing a digital annunciator or other monitoring


Monitors device – acts as a final safety measure to
The Altronic DET-1600/1620 Detonation shut down the engine.
Sensing Monitors are 24VDC-powered,
The DET system is housed in a rugged,
32-bit microprocessor-based electronic
powder-coated, aluminum enclosure
instruments designed for use on natural
and features an integral 2x16 character
gas-fueled engines to detect detonation
backlit LCD to display the detonation and
and misfire and avoid consequential
misfire reference level numbers, engine
engine damage. Industry-standard, low-
cylinder labels, control and output switch
cost, piezoelectric vibration sensors are
status, the cause of shutdown log, and all
mounted directly on the engine and are
diagnostic messages. System configura-
used to transform the vibrations caused
tion is accomplished using an on-board CERTIFIED
by combustion into electrical signals CLASS 1
RS485 serial port and a powerful, yet DIV. 2
which are then evaluated by the DET- GROUPS C & D
easy to use, system configuration and
1600/1620. These values – generated for
monitoring program.
every cylinder on a cycle-by-cycle basis
HOME SCREEN GLOBAL SYSTEM STATUS
– are then measured against misfire and
„„ Moderately-priced system protects
detonation setpoints configured by the natural gas-fueled engines from
user for the monitored engine. The moni- destructive knock/detonation
tors accept up to 16 detonation sensors „„ Monitors the engine for in-cylinder
CYLINDER REF. NUMBER REF. NUMBER
wired to pluggable Phoenix-type connec- misfire conditions NUMBER VS VS
DETONATION MISFIRE
tors; the recommended configuration is „„ Automatic load reduction and engine SETPOINT SETPOINT

one sensor per cylinder. shutdown functionality


DETONATION SENSED INDIVIDUAL CYL STATUS
„„ Can be connected to most Altronic
The DET system can be configured to
digital ignition systems for automatic
take a number of control actions to pro- timing retard control in the event of
tect the monitored engine upon indication detonation
of detonation (or misfire). In many ap- „„ Model DET-1620 for large bore, slow BARGRAPH DISPLAY OF ALL CYLINDERS
plications, the DET will utilize one of two speed engines using Altronic’s CPU-
2000 ignition system
solid-state output switches to activate an
external unloader to reduce engine load.
Should that remedial action be unsuc- TERMINAL PROGRAM
cessful addressing the detonation issue,
the DET can be configured (when used in
conjunction with a digital ignition system)
to automatically retard the ignition tim-
ing. In the event that an ignition timing
adjustment also proves to be ineffective
in eliminating engine detonation, the
second output switch – typically tied to

All rights reserved


© ALTRONIC, LLC 2012 17
ADI-C 3-12
Temperature/Pressure/Vibration Instrumentation

VSM Vibration Sensing Monitor of the device using the system keypad
The VSM is a 32-bit microprocessor- or through the use of the VSM Terminal
based electronic instrument designed to Program included with each unit.
protect industrial engines, compressors,
The VSM is housed in a 6.50" x 6.50"
and associated equipment from damage
powder-coated aluminum case for maxi-
caused by excessive vibration. The moni-
mum durability in difficult applications.
tor accepts up to four (VSM-400) or eight
Rugged, pluggable Phoenix-type connec-
(VSM-800) industry-standard low-cost,
tors are used for all input/output connec-
broadband, piezoelectric vibration sensors
tions to assure long-term, reliable system
that are used to transform mechanical
service. Each VSM is also certified as
vibrations into electrical signals which are
safe for use in Class I, Division 2, Group
then evaluated by the VSM. The resulting
C and D hazardous operating areas by the
vibration levels are displayed on a LCD CERTIFIED
Canadian Standards Association (CSA). CLASS 1
display and are compared to user adjust- DIV. 2
GROUPS C & D
able setpoint levels (2 per channel). If a
„„ Effectively protects natural gas-
high vibration level surpasses a user- fueled engines from damage due to HOME SCREEN
configured setpoint value, an indication is excessive vibration CHANNEL VIBRATION
NUMBER/LABEL LEVEL
shown on the LCD and an output switch „„ A single VSM can monitor all
— one for alarm and one for shutdown — major vibration points of interest
is activated. on a natural gas or diesel engine,
compressor (air or gas), pump, or
With each input channel operating other process
independently of the other, the VSM can „„ Accepts up to 4 (VSM-400) or 8 GLOBAL SYSTEM STATUS
BARGRAPH SCREEN
be used as the monitoring device for (VSM-800) low-cost, piezoelectric
vibration sensors as system inputs
all of the vibration points of interest on
an application. For example, individual „„ Eliminates on-engine mechanical
vibration switches that are vulnerable
sensors mounted on a gas compres-
to misapplication, setpoint SHUTDOWN SETPOINT SCREEN
sor cooler, on each bank of the engine, tampering, and physical damage
and on the compressor cross-heads are
„„ Includes alarm and shutdown
individually configured for the appropriate setpoints and outputs
vibration characteristics and monitored
„„ Full Modbus RTU communications
by a single VSM device. RS-485 Modbus supported for remote monitoring
RTU communications is resident in the
device allowing the vibration data from
each channel to be communicated to a
control PC/PLC or remotely as a means of
determining the overhaul health and well-
being of the equipment. Configuration of
the device can be accomplished simply
and conveniently directly from the front

All rights reserved


© ALTRONIC, LLC 2012 18
ADI-C 3-12
End Devices

GSV-Series Gas Shutoff Valve The GSV can be safely used in hazardous a 2" NPT threaded connection for direct
The GSV-series Gas Shutoff Valve auto- areas with suitably approved safety shut- installation into the wall of the pressure
matically interrupts down and control systems, including all vessel or weld collar or can be adapted for
the flow of fuel in Altronic annunciators. The GSV features use in conjunction with an external float
the event that an an industry-standard body size and thread chamber. As condensate or other liquids
engine or process specifications, and can be used as a re- rise or fall within the monitored vessel
fault is detected placement for existing gas shutoff valves, (scrubber), the float/arm assembly on the
by a supervisory such as the M50. “wet” side of the LLS deflects and moves
safety shutdown „„ Two models; 2" NPT an arm, causing the single pole, double-
system such as — CD ignition powered (690040-1) throw micro-switch in the “dry” side to
the Altronic DD- or DE-series — 12–24 VDC powered (690045-1) trip. The connection between the two
CERTIFIED
annunciator/controllers. CLASS 1 „„ Simple, direct-acting valve latching cavities is a magnetic field and requires
DIV. 1 & 2
GROUPS C & D mechanism for improved reliability no ports or wiring orifices. Both low and
Two models are available: and extended service
high level monitoring applications can
CD Ignition Powered is opened manu- „„ Unique, highly-visible valve position be accommodated through the use of the
indicator/manual stop button
ally, is held open mechanically, and draws appropriate micro-switch contacts within
no electrical power. The valve closes when „„ Directly replaces traditional gas the device.
shutoff valves, including M50
its internal coil is energized by a pulse
The Altronic LLS Level Switch is designed
from a shutdown system.
LLS-Series Liquid Level Switch as an explosion-proof device and is certi-
12–24 VDC Powered (Failsafe) The Altronic LLS represents the next fied by CSA for use in Class 1, Division 1
is opened manually and held open electro- generation in liquid level and 2, Groups C and D hazardous areas.
mechanically. It uses a voltage regulator protection for gas compres- Designed to meet industry-standard
circuit to keep current draw independent sor scrubbing and dehydra- mounting and installation specifications
of the DC voltage applied and to a low tion units as well as other (body size and threads), the LLS can be
0.2 amps maximum in the energized applications. Featuring used as a replacement for existing single-
(open) mode. The valve closes when its a unique isolated cavity cavity designs, including the L1200.
internal coil is de-energized by a shut- for the electrical switch
down system. and wiring, the design „„ High/low liquid level protection
for gas compressors and other
of the LLS eliminates
An external indicator shows whether the applications
the possibility of
valve is open or closed. The valve has a „„ Dual chamber design delivers better
leakage and liquid contami-
positive closure and vents gasses after long-term service and reliability
nation of the electrical switch
shutdown. Mounted on the top of the valve CERTIFIED „„ All stainless-steel construction for
and connections– the leading CLASS 1

body, this indicator button can also be DIV. 1 & 2 superior corrosion resistance
cause of premature failure GROUPS C & D

used as a manual stop to close the valve „„ Directly replaces traditional liquid
of similar float switches cur-
and stop the flow of fuel to the engine. An level switches
rently in service.
internal micro-switch which actuates on
shutoff can be used for remote indication This high-quality, all stainless-steel,
of fuel status or for other purposes. float-activated design is equipped with

All rights reserved


© ALTRONIC, LLC 2012 19
ADI-C 3-12
Instrument Accessories

Altronic Magnetic Pickups Altronic Barriers


AItronic magnetic pickups (691118-X) The Altronic 690107 and 690108 series Barriers are designed
are high-sensitivity designs and are intrinsi- to accept input from an Altronic C.D. ignition system and to
cally-safe for use in Class I, Division 1, Groups A, B, output an intrinsically-safe signal to oper-
C, and D hazardous areas. The table below represents available ate most Altronic ignition-powered digital
pickup lengths. instruments. The table below identifies the
5/8-18 UNF-2A SUFFIX DIM. T" appropriate barrier for use with the appropri-
-1 1.75"
ate Altronic ignition system. When used with
-2 2.50"
the correct barrier, most Altronic digital instruments achieve full
.800 DIA -3 3.00"

-4 4.50" CSA certification for safe use in Class I, Division 1, Group D haz-
T 1.550
-6 6.00"
ardous areas without the need for an explosion-proof enclosure.
T + 1.550 1.75
CONNECTOR Please refer to the individual product data sheets and installa-
CLEARANCE
tion instructions for complete details on individual certifications.
Altronic Pressure and Temperature Transducers
Barrier Model Applicable Altronic Ignition Systems
A comprehensive line of moderately ­priced, yet high quality
690107 Altronic I, I-6, III, III-CPU, V, CPU-90/95, DISN
pressure transducers complements the Altronic line of control-
690108 Altronic II, II-CPU, CPU-2000
lers and monitoring instruments. A variety of pressure ranges are
available, with both psia and psig configurations available.
Industrial and Explosion-Proof Enclosures
A unique series of proprietary temperature transducers is also Enclosures for both the 4-1/2" round and rectangular JIC enclo-
available. These devices are manufactured in two ranges: +5°F sure instrument products are available as accessory items. Both
to 350°F (-15°C to 176°C) and -40°F to 450°F (-40°C to 232°C) enclosure varieties are available for purchase at the time the
and are ideal for monitoring process gas temperatures. The use instrument is ordered, and as an independent part number.
of temperature transducers also enables the use of the same
„„ (-W) Industrial Enclosure (690014-1)
monitoring devices used for monitoring pressures and other analog is a gasketed, anodized aluminum
inputs, such as the DSM-4688/4689DUS and the DSG-1601DU. enclosure available for 4-1/2" round
instruments only. The device retains its
Pressure Pressure Class I, Division 2, Group D rating when
691201 Series 691204 Series
mounted in this enclosure. It has a
bottom conduit entry for wiring and can
be wall or conduit ­mounted.

„„ (-X) Explosion-Proof Enclosure can be


used to achieve a Class I, Division 1,
Group D certification where necessary.
Temperaure Temperaure It is available for both 4-1/2" round
691202/212 Series 691203/213 Series
(690013-1) and rectangular JIC-cased
devices (690012-1).
NOTE:
OUTPUT CONNECTOR MATES WITH
PACKARD METRI-PACK #12065287

All rights reserved


© ALTRONIC, LLC 2012 20
ADI-C 3-12
Custom Control Panel Design and Manufacturing

Each AC panel follows the same sequence Construction and Testing/Validation of


of development. the Control Panel
Altronic Controls After the development and design stage,
Establishing the Specification
2350 Crist Road, Suite 1000 responsibility shifts to the Altronic Con-
Determining which points are to be
Garland, Texas 75040 trols production and quality assurance
monitored and/or how the engine is to be
Tel (972) 494-0522 group. A control
Fax (972) 530-7216 controlled through the start, warmup, run,
panel is much
sales.altronic.garland@hoerbiger.com and shutdown cycles is clearly the most
more than a box
critical portion of the panel development
full of boxes. A
process. Altronic field personnel, in con-
reliable panel that
junction with distributor sales and service
will provide the
groups, work closely with the customer to
customer with
properly understand the application and
long-term, trouble-
the desired control strategy.
free service must be constructed in accor-
Turning the Specification into a Reli- dance with a strict set of assembly guide-
Altronic Controls (AC) designs and builds able, Cost-Effective Design lines. This includes termination ferrules
custom, premium-quality control panels. Using Altronic instrumentation and and wire tags on every wire, well-routed
As of late 2011, AC is operating from control products—as well as complimen- tubing, separated low and high voltage
its new, larger (40% more space) facility tary products built by other manufactur- wiring, and high quality enclosures and
pictured here. Using Altronic CSA-certified ers—the engineers at AC must insure that finishes. It also means rigorously testing
instrumentation and controls, virtually any the provided specifications and control every electrical or process tubing point in
safety shutdown, engine control, or auto­ requirements are met with a reliable, cost­ the panel with either high pressure air or
mation panel requirement can be met. AC effective controls solution. This requires hydraulics, calibrating all transducers to
specializes in panels for the oil and gas in- attention to de- the instrument, and checking every func-
dustry that operate in challenging environ- tail and relies on tion in the panel.
ments including hazardous duty locations more than 100
man-years of
Installation and Commissioning
where instruments labeled as “suitable for
Drawing on its technical staff, as well as
use” simply do not measure up. cumulative con-
the expertise of Altronic Regional Man-
trol panel design
Designing and constructing control panels agers and authorized Distributors, the
experience at
for the oil and gas industry is a customer- Altronic Controls team is unparalleled in
Altronic Con-
intensive process. From the specification the industry in its ability to properly and
trols. It may also
phase, through the panel installation and economically install and start up a control
include further
commissioning effort, AC engineers, along panel. With trained Distributor installa-
consultation with
with distributor sales/service specialists, tion and service personnel located all over
the customer to
work close­ly with the customer to assure the world, the control panel end user is
suggest alternate design approaches or
that the panel approach, design, and assured of an effective, reasonably priced,
controls to better suit the application or
construction meet the operational, service, and timely response to any technical issue
budgetary requirements.
and environmental dura­bility requirements that might arise throughout the service
unique to each location and application. life of the product.

All rights reserved


© ALTRONIC, LLC 2012 21
ADI-C 3-12
Control Panels from Altronic Controls

Engine, compressor, and pump-monitoring and control panels are DE-3000 Monitoring and Control Panels
available in a range of sizes and shapes, with an equally broad DE-3000 panels from Altronic Controls offer additional function-
array of capabilities. From simple monitoring and protection ality and control capability in addition to monitoring and safety
to more active engine or process control, Altronic Controls can shutdown features. The DE-3000 panels can accept up to 62
deliver exactly the right mix of Altronic and non-Altronic hardware discrete, thermocouple or analog inputs with up to 24 outputs
to meet the specific needs and budget of the user. provided. Multiple alarm set points are available for each analog
input, and serial ModBus RTU and ASCII protocols allow direct
DD-40NTV Safety Shutdown Panels
remote access to system operating conditions via satellite, radio,
For the user seeking simple but effective engine/package protec-
cellular or landline communications. The DE-3000 also provides
tion, Altronic Controls offers Altronic DD-40 and DD-40NTV-
active, closed-loop control for a variety of functions, including
based shutdown panels. Designed for small and medium-sized
compressor slide valve and recycle valve control. See page 6 for
applications, these panels often feature high-quality 45PHL
a more complete description of DE system capabilities..
Pressure Switch-Gauges and other Altronic temperature monitor-
ing instrumentation. The familiar Altronic DD annunciators feature
a 2-digit display of mode or fault data which conveys essential
information common to any language and requiring no special
operator training for operation. Many thousands of these panels are
in operation today in gas fields all over the world. See page 4 for
further information.

All rights reserved


© ALTRONIC, LLC 2012 22
ADI-C 3-12
Altronic PLC+ Panels Altronic Exacta21 Monitoring and Altronic Air/Fuel Ratio Control Panels
Altronic offers customized PLC solutions Control Panels for Gas Compressors Built into a stand-alone enclosure, or
for a wide range of applications. The Altronic Controls offers a full line of integrated into a larger safety-shutdown or
Altronic PLC+ control panel pairs a proven control panels constructed around the control system, the Altronic EPC-series air/
Allen-Bradley PLC from Rockwell Automa- purpose-built Exacta21 gas engine or fuel ratio control systems can be packaged
tion with application-specific hardware compressor controller (see pages 8 and 9). to meet virtually any application require-
from Altronic for engine/compressor These high-end control systems—most ment. If you need to upgrade to meet new
functions such as detonation, vibration, frequently used on larger field gas com- emission requirements, an AC air/fuel ratio
governing, and air/fuel ratio control. This pression units, in gas processing service, auxiliary panel is an ideal “bolt-on” solu-
provides end users having a preference or on mainline gas transmission compres- tion where additional monitoring or control
for PLC technology with a high quality, sors—offer comprehensive monitoring and functionality is not required.
high reliability control solution tailored control capabilities, and often incorporate
specifically for engine/compressor control. advanced HMI (human machine inter-
A unique programming structure assures face) modules such as the MIDAS system.
ease of set up and operation with familiar
PLC configuration. These systems offer
MIDAS HMI Control System
comprehensive monitoring and control
MIDAS (Monitored Information Devices
capabilities using touchscreen HMIs such
And Systems) combines the advanced
as the MIDAS system (outlined below) and
display capabilities of a PLC-based sys-
can be expanded to cover virtually any ap-
tem with the reliability and serviceability
plication requirement.
of a control panel built around inde-
pendent, discrete devices. Using “pre-
manufactured” system data screens and
a standard display structure, the MIDAS
acts as a data collection and presenta-
tion hub. The touch screen provides an
advanced, user-configurable, graphical
data presentation, delivering centralized
access to critical information in parallel
with the individual instrument and control
displays and keypads within the panel.

All rights reserved


© ALTRONIC, LLC 2012 23
ADI-C 3-12
Altronic, LLC – A Member of
the HOERBIGER Group

The HOERBIGER Group

HOERBIGER Compression Technology is a business unit of HOERBIGER Holding AG,


Zug / Switzerland. HOERBIGER is active throughout the world as a leading player in the fields
of compression technology, automation technology and drive technology. Its 6,400 employees
achieve sales of around 1 billion Euro. The focal points of its business activities include key
components and services for compressors, gas engines and turbomachines, hydraulic systems and
piezo technology for vehicles and machine tools, as well as components and systems for shift and
clutch operations in vehicle drive trains of all kinds. Through innovations in attractive technological
niche markets, the HOERBIGER Group sets standards and delivers cutting-edge solutions for the
benefit of its customers.

ALTRONIC, LLC ALTRONIC CONTROLS Form ADI-C 3-12


712 Trumbull Avenue 2350 Crist Road, Suite 1000
Girard, Ohio 44420 USA Garland, Texas 75040
P: 330-545-4045 P: 972-494-0522
F: 330-545-3231 F: 972-530-7216