Temperature variation in a heat exchanger
4
5
6
HEAT EXCHANGERS
Applications
• Automobiles (Radiators, Air preheater, Exhaust gas heat removal)
• Gas turbines
• Cooling towers
• Industrial Furnaces (Economizers)
7
8
LMTD Method
[(T1 t1 ) (T2 t 2 )]
(T ) lm
(T t )
ln 1 1
(T2 t 2 )
For a Counter flow:
where
[(T t ) (T2 t1 )]
(T ) lm 1 2 T1 – Entry temperature of hot fluid
(T1 t 2 ) T2 – Exit temperature of hot fluid
ln
(T
2 1 t ) t1 – Entry temperature of cold fluid
t2 – Exit temperature of cold fluid
26
LMTD Formulae
2) Heat lost by hot fluid = Heat gained by cold fluid
Qh = Qc
A = π Di L Q = m x hfg
Where Where
Di – Inner diameter hfg – Latent heat (J/kg K)
27
DATA BOOK:
28
PROBLEMS
29
1. In a double pipe heat exchanger, hot fluid with a specific heat of 2300
J/kg-K enters at 380 oC and leaves at 300 oC. Cold fluid enters at 25oC and
leaves at 210 oC. Calculate the heat exchanger area required for
(i) Counter flow
(ii) Parallel flow.
Take overall heat transfer coefficient as 750 W/m2 K and mass flow rate of
hot fluid is 1 kg/s.
2. In a counter flow single pass heat exchanger is used to cool the engine
oil from 150o C to 55o C with water, available at 23o C as the cooling
medium. The specific heat of oil is 2125 J/kg K. The flow rate of cooling
water through the inner tube of 0.4 m diameter is 2.2 kg/s. The flow rate of
oil through the outer tube of 0.75 m diameter is 2.4 kg/s. If the value of the
overall heat transfer co-efficient is 240 W/m2K, how long must the heat
exchanger be to meet its cooling requirement?
30
LMTD Problems
1. In a double pipe heat exchanger, hot fluid with a specific heat of 2300
J/kg-K enters at 380 oC and leaves at 300 oC. Cold fluid enters at 25oC and
leaves at 210 oC. Calculate the heat exchanger area required for
(i) Counter flow
(ii) Parallel flow.
Take overall heat transfer coefficient as 750 W/m2 K and mass flow rate of
hot fluid is 1 kg/s.
Given:
Hot fluid Cold fluid
(T1, T2) (t1,t2)
Mass flow rate of hot fluid), mh = 1 kg/sec
Solution:
We know that,
Heat transfer, Q = mcCpc(t2 – t1) = mh Cph(T1 – T2)
=> Q = mhCph(T1 – T2)
[since Specific heat & flow rate of hot fluid is known]
Q = 184 x 103 W
We know that,
Heat transfer, Q = UA (∆T) lm (1)
[From HMT book, Pg no: 151]
where (∆T) lm - Logarithmic mean temperature difference (LMTD)
Inference:
Counter flow heat exchanger is more effective compared to parallel flow heat
exchanger
33
LMTD Problems
2. Water flows at the rate of 65 kg/min through a double pipe, counter flow
heat exchanger. Water is heated from 50o C to 75o C by an oil flowing
through the tube. The specific heat of the oil is 1.780 kJ/kg K. The oil
enters at 115o C and leaves at 70o C. The overall heat transfer co-efficient
is 340 W/m2K. Calculate the following
1. Heat exchanger area
2. Rate of heat transfer
Given:
Hot fluid – oil, Cold fluid – Water
(T1, T2) (t1,t2)
Mass flow rate of water (cold fluid), mc = 65 kg/min = 65/60 kg/s =1.08 kg/s
We know that,
Area, A = π x Di x L
L = A / (π x Di ) = 31.9 m
38