RCP2-1100/RCP2-1200
FPRC-1100/FPRC-1200
FEATURES
Description: • Menu Driven display
for user friendly
The Teledyne Paradise Datacom family of Redundant System monitor and control
Controllers is used to monitor and control amplifiers configured • Front Panel Display
in 1:1 and 1:2 redundant systems. of Signal Path
for intuitive operation
• Parallel I/O; Form C
The RCP2-1100 and FPRC-1100 controllers provide control of Contact Closure Outputs &
two amplifiers and their corresponding transfer switch. The Opto-Isolated Inputs
RCP2-1200 and FPRC-1200 controllers monitor and control • 1 Rack Unit height to max-
three amplifiers and two switches. imize cabinet space
• RS-232/485 Serial
Interface for Remote M&C
The RCP2/FPRC Series of redundant controller can be used in • Audible alarms
LNA, LNB, and SSPA systems as well as frequency converter • Removable power supplies
systems. They feature a full mimic panel and menu-driven • Field programmable
Vacuum Fluorescent Display all in one rack unit of cabinet firmware
space. Front panel fault lights and an audible alarm are • Windows®-based
available for fault detection. remote M&C Software
• Ethernet Port
Completely redundant power supplies are incorporated with OPTIONS
universal input and power factor correction. System control is • Remote Control Panel
available through the front panel (local mode), or through the • Control Panels for
Phase Combined SSPA
rear panel parallel I/O remote, or serial I/O remote modes. Systems
• Adapter cables for
The use of flash memory allows easy field programmable compatibility with previous
firmware updating. generation systems
• DC Operation
System Fault Signal Path VFD Display Auto / Manual Display Navigation
Identification Indicators mimic display Mode Key Keys
GENERAL SPECIFICATIONS
Characteristic Specification
Configurations RCP2-1100; 1:1 Redundant System
RCP2-1200; 1:2 Redundant System
FPRC-1100; 1:1 Redundant / Phase Combined System
FPRC-1200; 1:2 Fixed Phase Combined System
Switch Time Fault Detection, 20 - 50 msec
Total Switchover (including mechanical switch) - 100 msec maximum
Switch Drive 26 VDC @ 5 Amps
Alarm Input Closure to Ground, (Ground=OK / Open=Fault)
Serial Communication RS232 / RS485 4 wire
Parallel I/O
Status Outputs Form C Relay Contacts (10 sets)
Control Inputs Contact Closure to Ground
AC Input Power 85-265 VAC, 47-63 Hz, 1 A max, > 0.93 power factor
DC Input Power 36-72 VDC, Maximum DC Input current @ 48V - 2 Amps
(48 VDC Input Option)
Mechanical
Dimensions 1.75 in. H x 19.0 in. W x 13.3 in D [1RU]
44.5 mm H x 483 mm W x 338 mm D
Weight 5 lbs. (2.3 kg)
Temperature 0 to 50 °C operating
Relative Humidity 95% non-condensing
The image on the left shows the fault indicators for RCP2-1100 and FPRC-1100 models;
the figure to the right shows the fault indicators for RCP2-1200 and FPRC-1200 models.
RCP2-1100
1:1 Redundant System Controller
(Switched input)
FPRC-1100
∑ 1:1 Phase Combined System Controller
(Split input)
RCP2-1200
1:2 Redundant System Controller
(Switched input)
FPRC-1200
1:2 Phase Combined System Controller
(Split input)
- 1 0 0
Use and Disclosure of Data: The items described herein are controlled by the U.S. Government and authorized for export only to the coun-
try of ultimate destination for use by the ultimate consignee or end-user(s) herein identified. They may not be resold, transferred, or other-
wise disposed of, to any other country or to any person other than the authorized ultimate consignee or end-user(s), either in their original
form or after being incorporated into other items, without first obtaining approval from the U.S. government or as otherwise authorized by
U.S. law and regulations.
Proprietary and Confidential: The information contained in this document is the sole property of Teledyne Paradise Datacom. Any repro-
duction in part or as a whole without the written permission of Teledyne Paradise Datacom is prohibited.