TELAL HOTEL AND APARTMENT

COMPLIANCE STATEMENT FOR


STRUCTURED CABLING SYSTEM

Section
TECHNICAL SPECIFICATIONS COMPLIANCE REFERENCE REMARKS
No.
1.0 GENERAL
The proposed solution must be the latest available technology for the COMPLY Refer to Datasheets in Section
structured cabling system. 7, pages 1, 5, 12, 16, 17, 22,
24, 26-33, 40-41, and 44 for
the latest standards of the
CAT6, Fiber optic, CAT3 cables
and connectors & accessories.
The contractor shall install complete end-to-end UTP Cat – 6 cabling system COMPLY
solution.
The proposed solution of UTP Cat - 6 must be provided with a minimum of COMPLY Refer to section 9 for
25 years performance warranty. Warranty Services of Excel
Networking Brand
Wherever the standards (EIA / TIA, Cenelec, ISO) are not ratified, the latest COMPLY Refer to Datasheets in
"Draft" shall be referred. Section 7, pages 1, 5, 12, 16,
17, 22, 24, 26-33, 40-41, and
44 for the latest standards of
the CAT6, Fiber optic, CAT3
cables and connectors &
accessories.
Wherever applicable, the latest version of DIC – Telecom Department (DIC- COMPLY
EITC-DU) “Design Guidelines for Telecommunications Infrastructure for New
Building” shall be referred or The Latest Revision of Etisalat Guide line for
FTTH.
All components pertaining to structured cabling system shall be from a COMPLY
single manufacturer and mixing of components from different
manufacturers shall not be accepted.
Contractor to obtain approval on drawings from DU / Etisalat for COMPLY As per latest Du
Telecommunications system installation and shall meet the local authorities Regulations, consultant has
requirements. to apply for approval of
Design Drawings for Design
NOC. We as the contractor
then will apply for
Construction drawings after
approval of shop Drawings
for Construction NOC.
2.0 SYSTEM SPECIFICATION
TELAL HOTEL AND APARTMENT
COMPLIANCE STATEMENT FOR
STRUCTURED CABLING SYSTEM

Section
TECHNICAL SPECIFICATIONS COMPLIANCE REFERENCE REMARKS
No.
The MDF shall be installed in industry standard 19" cabinet COMPLY Refer to Datasheet in Section
7, Page 53-56, Part no. 542-
42810-GSBF-BK as the
1. proposed MDF.
Single mode fiber optic cables shall be installed between MDF and IDF or COMPLY
2. ACP
The fiber optic back bone cables shall be terminated on 19” fiber patch COMPLY
3. panel (2 core or multi core whatever applicable).
Locations of IDF shown on drawings are indicative only. The final location COMPLY
shall be as per DU/ETISALAT approval and all the multi core and 2 core fiber
optic cable shall be terminated if applicable.
4.
The ACP size and location shall be as per DU/Etisalat approval and 2 core COMPLY
fiber optic cables shall be terminated on approved enclosure.
5.
2 core drop fiber cable shall be having at least 2 steel wires as a strength COMPLY Refer to Section 7, Datasheet Cable design comprises 2
member. for 2-Core Singlemode F.O.C. Aramid Reinforced Plastic
on page 40-41 for Approved rods which is in line with
Du Fiber Cable. the local Telco
6. requirements
No. of cores to the office, retail and apartment will be as per latest COMPLY
7. Telecommunication Provider Standards.
2.1 SCOPE OF WORK
The contractor should install and hand over the project to DU/Etisalat as per COMPLY
there latest guideline.
3.0 PRODUCT SPECIFICATIONS:
Horizontal Cable:
The horizontal cable shall constitute of four (4) Twisted Pair (UTP), solid COMPLY AS NOTED Refer to Section 7, Page 1&2 Cable provided meets IEC
copper conductors AWG24. The outer sheath shall be LSZH and the cable for CAT6 Cable Datasheet, 60332-1 fire performance is
shall be specified up to 350 MHz or better and should have the following PVC Outer sheath. provided.
values or better for Attenuation and NEXT:
TELAL HOTEL AND APARTMENT
COMPLIANCE STATEMENT FOR
STRUCTURED CABLING SYSTEM

Section
TECHNICAL SPECIFICATIONS COMPLIANCE REFERENCE REMARKS
No.
Frequency Attenuation NEXT (dB) COMPLY Refer to Datasheet on Section Comply to all ISO/IEC, EN &
(MHz) (dB) 7, page 2 for the table of TIA standards requirements
compliance of the level of
1 2.0 74.3 Attenuation as per the latest
4 3.8 65.3 International standards.
10 6.0 59.3
16 7.6 56.3
20 8.5 54.8
31.2 10.6 51.9
62.5 15.3 47.4
100 19.6 44.3
250 32.3 38.3

• The horizontal cabling shall be star-wired. COMPLY


The maximum horizontal distance shall be 90Mtr. between the outlet and COMPLY
the patch panel (excluding patch cords and line cords).

• The horizontal cabling shall be free of taps and bridges. COMPLY
One cable shall be strictly used for one application; cable sharing will not be COMPLY
• acceptable.
The horizontal cables proposed must be from the same manufacturer COMPLY
as the other components proposed for outlets and patch panels etc.

All pairs are color coded and shall have an impedance of 100 ohms, with a COMPLY
• tolerance of +/- 15 Ohms
The cable shall be ETL listed COMPLY The cables are EC Verified &
Listed, complying with the
latest standard of CAT6 cable
as per Delta –Denmark which
is a third party Certification
• Body.
3.0 Work Area Telecommunications Outlet/Connector
TELAL HOTEL AND APARTMENT
COMPLIANCE STATEMENT FOR
STRUCTURED CABLING SYSTEM

Section
TECHNICAL SPECIFICATIONS COMPLIANCE REFERENCE REMARKS
No.
The Work Area telecommunications outlet/connector is the interface COMPLY
between the horizontal wiring and the work area.
The telecom outlet/connector shall be based on widely used RJ45 interface COMPLY Refer to Datasheet of RJ45
and shall feature excellent transmission performance and mechanical Connector/Keystone Jack as
strength per page 5-7, part no. 100-
011BK.
The telecom outlet/connector shall have characteristics of UTP Cat 6 COMPLY Refer to Datasheet of RJ45 Connectors are third party
enhanced up to 350MHz and shall be from the same structure cabling Connector/Keystone Jack as certified from 3P Labs –
system manufacturer. per page 5-7, part no. 100- Denmark. Certification
011BK. attached, refer on Section
7.
Telecommunications outlet/connector shall not allow more than only one COMPLY
single connection to horizontal cable as per TIA/EIA 568B standard.

The contact wires (connector) shall be coated with at least 50um of hard COMPLY Refer to Section 7, Page 6
gold.
The Outlet/Connector to be ETL listed COMPLY The connectors are EC Connectors are third party
Verified & listed. Connectors certified from 3P Labs –
comply to the latest standard Denmark. Certification
of CAT6 connector as per 3P attached, refer on Section
Labs – Denmark, which is a 7.
third party Certification Body,
refer to Section 7, pages 5-7.
All Cat 6 RJ45 outlets should be mounted in 25mm x 50mm shutters, in COMPLY Refer to Section 7, page 8-11
single or double gang faceplate. All RJ45 outlets should be fitted with spring for the datasheet of Faceplate
loaded sliding shutters to prevent the ingress of dirt and dust. with part no. 100-712, and
100-020 for the shutter.
It should be possible to use the same RJ45 interface module at the outlet COMPLY
end as well as the patch panel (IDF) end. Patch Cords & Line Cords:
TELAL HOTEL AND APARTMENT
COMPLIANCE STATEMENT FOR
STRUCTURED CABLING SYSTEM

Section
TECHNICAL SPECIFICATIONS COMPLIANCE REFERENCE REMARKS
No.
The patch cords and line cords shall constitute of two modular RJ45 plugs COMPLY Refer to Section 7, page 12 to
assembled on twisted pair stranded cable. The UTP stranded cable shall be 14 for the datasheet of the
constructed using AWG24 flexible cable. The sum length of all patch cords & CAT6 Patch cords, with part
line cords for one outlet shall not exceed 10Mtr. Under no circumstances no. 100-310 and 100-312.
shall locally assembled patch cords and line cords will be acceptable, all
must be factory made. All line and patch cords shall be Cat 6 rated and shall
be of the same material of horizontal cables, The characteristic impedance
of the pairs must be identical to that of the horizontal cables.

All cords shall be covered by the manufacturer’s warranty and certification. COMPLY

All cords shall be transferable to any channel without degrading channel COMPLY
or system performance and not be required to remain on the channel
where tests were performed in order to maintain certification

6.0 INSTALLATION
The vendor will accept complete responsibility for the design, COMPLY Refer to Section 4 for the
installation, certification, and support of the cabling system. Vendor Partnership Letter from
must show proof that he has been certified by the manufacturer’s on Manufacturer.
all of these issues.
The telecommunications technicians employed shall be fully trained COMPLY
and qualified by the manufacturer on the installation and testing of the
equipment to be installed. Evidence that the vendor is a current certified
installer of the manufacturer must be provided in writing prior to
commencing work on the structured cabling for the building.

The contractor/vendor shall not engage any sub-contractor to carry out the COMPLY
structured cabling work and shall show proof of a contractual relationship
with the manufacturer, and shall pass the manufacturer's certification to
purchaser.
The installation shall comply with the requirements of ISO-11801 Class E as COMPLY
appropriate.
The structured cabling system (cables, RJ45 outlets, panels etc) shall be COMPLY
labeled in accordance with EIA / TIA-606.
TELAL HOTEL AND APARTMENT
COMPLIANCE STATEMENT FOR
STRUCTURED CABLING SYSTEM

Section
TECHNICAL SPECIFICATIONS COMPLIANCE REFERENCE REMARKS
No.
7.0 TESTING
The contractor shall test and demonstrate on site, to the satisfaction of the COMPLY Testing shall be carried out
engineer, that the wiring is in full compliance with specific requirements of as per the Latest ISO/IEC
a Class - E installation (350 MHz). All the tests shall be carried out in 11801 Class E and as per
accordance with TIA/EIA standard. ANSI/TIA/EIA 568-C
Standard which is with up
to 250MHz.

The contractor shall provide test results (both hard copy and soft copy) for COMPLY
every data and every voice outlet using DTX1800 tester.

8.0 DOCUMENTATION
The contractor shall submit a set of documentation comprising of layouts COMPLY
showing cable route & position of all outlets, labeling scheme, layout of
cabinets and test results.
9.0 WARRANTY
The Manufacturer to provide through the specialist contractor 25 years COMPLY Refer to section 9 for
component and system performance warranty. Warranty Services of Excel
Networking Brand
10.0 GSM
Contractor shall provide the following and comply with requirements of Du COMPLY AS NOTED Under the scope of works of
GSM Department. MEP
Power supply and AC in GSM Room. COMPLY AS NOTED Under the scope of works of
MEP
Drain pit. COMPLY AS NOTED Under the scope of works of
MEP
Cable tray / trunking containment. COMPLY AS NOTED Under the scope of works of
MEP
Installation of GSM Cables. COMPLY AS NOTED Under the scope of works of
MEP
20 Pair (or as required by Du) cable installation between MDF and GSM COMPLY
room.
END OF SECTION