Sunteți pe pagina 1din 2

INTROS

Rope Inspection
Report
Test Number : Inspection date : 7/18/2023 6:40 AM
File : D:\Wintros_2.5_e\slb INTRON\J2.slb
Applicaion :

Rope
Diameter : 16.4 mm
N Full Length : 0 m Install date : 12/30/1899
Previous test date : 12/30/1899
Instrument

Unit : BU 16MB/USB S/N : 405088 version 5.15


Magnetic Head : MH 6-24 S/N : 1562

Test condition
Speed : 0.0 m/s
Travel direction : direct

Results
Segment examined length 29.72 m from -29.64 m
Maximum LMA value : 143.33 % at -0.06 m Minimum LMA value : -100.0 % at -28.81 m
Total length : where LMA is more 12% - 0.3 m where LMA is more 15% - 0.3 m
Maximum LF signal : -1.4 at -29.64 m ( threshold 10mV ) LF Noise : 2mV

LMA, % 143.3% LF
25
3
20

15 15% 2 20mV
12%
10
1 10mV
5
-29.64

0
-25 -20 -15 -10 -5 0
Distance, m Distance, m

9/18/2012 1
INTROS

LMA trace, %
150.0

100.0

50.0

0.0

-50.0

-100.0
-28 -26 -24 -22 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0
Distance, m

LF trace, mV

5.0

0.0

-5.0

-10.0

-28 -26 -24 -22 -20 -18 -16 -14 -12 -10 -8 -6 -4 -2 0
Distance, m

9/18/2012 2