Completed Procedure Report

Start Date/Time: 7/24/2016 8:30 AM On Demand: False


Completed Date/Time: 7/24/2016 8:52 AM In Progress: False
Trans. Date/Time: 7/24/2016 4:00 PM Completed By: SUWARDY, SYAHMUDIN
(1021775)
Approved Date/Time: Approved By:
line line line line

P2 U-100/U-1500 Day 10am


Plant status for 1000hrs

Please select current plant status (Normal or Abno


rmal)

Task Group Status: Normal 7/24/2016 8:30 AM

Normal Condition

Decision: True 7/24/2016 8:30 AM

Proceed with structured round?

Proceed with structured round?

Task Group Status: Yes 7/24/2016 8:30 AM

Yes

Decision: True 7/24/2016 8:30 AM

Fuel & Feed Gas Header-SP Fuel & Feed Gas Header-SP
Fuel & Feed Gas Header (Scan Point). Please scan t Fuel & Feed Gas Header (Sc
o unlock. an Point)

Task Group Status: Tag Scanned 7/24/2016 8:31 AM


010-PI-0155 34 BarG 7/24/2016 SUWARDY,
8:31:47 AM SYAHMUDIN
(1021775)

Fuel & Feed Gas Header


Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and Contact Panel Man if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and Contact Panel Man if necessary.
010-PI-0152 59 BarG 7/24/2016 SUWARDY,
8:31:48 AM SYAHMUDIN
(1021775)

Fuel & Feed Gas Header


Pressure Low : 6060 OPN - Pressure Low

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 1 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Pressure Low! Please check and Contact Panel Man if necessary.


Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and Contact Panel Man if necessary.
R-01002 A/B-SP R-01002 A/B-SP
R-01002 A/B (scan point) contain of R-01002A & R-0 Desulphurization Unit (Sca
1002B. Please scan to unlock. n Point)

Task Group Status: Tag Scanned 7/24/2016 8:44 AM


010-PI-0252A 48 BarG 7/24/2016 SUWARDY,
8:44:09 AM SYAHMUDIN
(1021775)

R-01002-A/B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
010-PI-0252B 48 BarG 7/24/2016 SUWARDY,
8:44:10 AM SYAHMUDIN
(1021775)

R-01002-A/B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
010-PI-0253 48 BarG 7/24/2016 SUWARDY,
8:44:11 AM SYAHMUDIN
(1021775)

R-01002-A/B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
E-01020 A/B-SP E-01020 A/B-SP
Oxygen pre heater (scan point). This scan point co Oxygen Pre Heater (Scan Po
ntain of E01020A/B, Cooling Water Jacket and F-010 int)
08. Please scan to unlock.

Task Group Status: Tag Scanned 7/24/2016 8:43 AM

E-01020A E-01020A
Oxygen pre heater A Oxygen Pre Heater

Task Group Status: 7/24/2016 8:43 AM


010-PI-2552 45 BarG 7/24/2016 SUWARDY,
8:43:36 AM SYAHMUDIN

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 2 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

(1021775)

E-01020A
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
E-01020B E-01020B
Oxygen pre heater B Oxygen Pre Heater

Task Group Status: 7/24/2016 8:43 AM


010-PI-2754 45 BarG 7/24/2016 SUWARDY,
8:43:38 AM SYAHMUDIN
(1021775)

E-01020B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
E-01003 E-01003
Waste heat boiler Waste Heat Boiler

Task Group Status: 7/24/2016 8:43 AM


010-PI-3152 50 BarG 7/24/2016 SUWARDY,
8:43:40 AM SYAHMUDIN
(1021775)

E-01003
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
ATR Cooling water jacket F-01008
ATR Cooling water jacket Cooling Water Jacket Vesse
l
Task Group Status: 7/24/2016 8:43 AM

G-01004A G-01004A
Cooling water jacket pump A Cooling water jacket pump
A
Task Group Status: Running 7/24/2016 8:43 AM
010-PI-2251A 0.6 BarG 6060 OPN - 7/24/2016 SUWARDY,
Pressure Low 8:43:49 AM SYAHMUDIN
(1021775)

G-01004A

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 3 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Pressure Low : 6060 OPN - Pressure Low


Pressure Low! Please check and contact panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
010-PI-2252A 5.6 BarG 7/24/2016 SUWARDY,
8:43:51 AM SYAHMUDIN
(1021775)

G-01004A
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
lube oil level 70 % 7/24/2016 SUWARDY,
8:43:52 AM SYAHMUDIN
(1021775)

G-01004A
Level Low : 6070 OPN - Level Low
Level Low! Please top up lube oil
G-01004B G-01004B
Cooling water jacket pump B Cooling water jacket pump
B
Task Group Status: Standby 7/24/2016 8:43 AM
010-PI-2251B BarG

G-01004B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
010-PI-2252B BarG

G-01004B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
lube oil level %

G-01004B
Level Low : 6070 OPN - Level Low
Level Low! Please top up lube oil
F-01001-SP F-01001-SP
F-01001 (Scan Point) contain of F-01001A/B and E-0 HP Steam Drum (Scan Point)
1003. Please scan to unlock

Task Group Status: Tag Scanned 7/24/2016 8:46 AM

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 4 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

F-01001A F-01001A
HP steam drum A HP Steam Drum

Task Group Status: 7/24/2016 8:46 AM


010-PI-3151 110 BarG 7/24/2016 SUWARDY,
8:46:12 AM SYAHMUDIN
(1021775)

F-01001A
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
010-LG-3151 45 % 7/24/2016 SUWARDY,
8:46:13 AM SYAHMUDIN
(1021775)

F-01001A
Level Low : 6070 OPN - Level Low
Level Low! Please check and contact panelman if necessary.
Level High : 6070 OPN - Level High
Level High! Please check and contact panelman if necessary.
F-01001B F-01001B
HP steam drum B HP Steam Drum

Task Group Status: 7/24/2016 8:46 AM


010-PI-3153 110 BarG 7/24/2016 SUWARDY,
8:46:15 AM SYAHMUDIN
(1021775)

F-01001B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
010-LG-3152 45 % 7/24/2016 SUWARDY,
8:46:16 AM SYAHMUDIN
(1021775)

F-01001B
Level Low : 6070 OPN - Level Low
Level Low! Please check and contact panelman if necessary.
Level High : 6070 OPN - Level High
Level High! Please check and contact panelman if necessary.
F-01008 F-01008
Cooling water jacket vessel Cooling Water Jacket Vesse
l

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 5 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Task Group Status: 7/24/2016 8:46 AM


010-LI-2251 100 % 6070 OPN - 7/24/2016 SUWARDY,
Level High 8:46:18 AM SYAHMUDIN
(1021775)

F-01008
Level Low : 6070 OPN - Level Low
Level Low! Please check and contact panelman if necessary.
Level High : 6070 OPN - Level High
B-01001-SP B-01001-SP
Primary Reformer B-01001 (Scan Point). This scan p Steam Reformer (Scan Point
oint contain of B-01001, E-01018II, E01012, E-0100 )
9, E-01013 and B-01002. Please scan to unlock.

Task Group Status: Tag Scanned 7/24/2016 8:46 AM

B-01001 B-01001
Primary Reformer Steam Reformer

Task Group Status: 7/24/2016 8:46 AM


010-PI-1254 1.6 BarG 7/24/2016 SUWARDY,
8:46:35 AM SYAHMUDIN
(1021775)

B-01001
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and contact panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and contact panelman if necessary.
E-01018 II E-01018-II
HP steam super heater HP Steam Superheater

Task Group Status: 7/24/2016 8:46 AM


010-PI-1253 110 BarG 7/24/2016 SUWARDY,
8:46:37 AM SYAHMUDIN
(1021775)

E-01018-II
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure Low! Please check and inform panelman if necessary.
E-01012 E-01012
Feed pre heater to pre reformer Feed Pre Heater Pre Reform
er
Task Group Status: 7/24/2016 8:46 AM
010-PI-1152 45 BarG 7/24/2016 SUWARDY,

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 6 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

8:46:40 AM SYAHMUDIN
(1021775)

E-01012
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
E-01009 E-01009
feed gas preheater to ATR Feed Pre Heater Secondery
Reformer
Task Group Status: 7/24/2016 8:46 AM
010-PI-2452 35 BarG 7/24/2016 SUWARDY,
8:46:41 AM SYAHMUDIN
(1021775)

E-01009
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
E-01013 E-01013
Natural gas pre heater Natural Gas Pre Heater

Task Group Status: 7/24/2016 8:46 AM


010-PI-0254 50 BarG 7/24/2016 SUWARDY,
8:46:46 AM SYAHMUDIN
(1021775)

E-01013
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-0255 50 BarG 7/24/2016 SUWARDY,
8:46:47 AM SYAHMUDIN
(1021775)

E-01013
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
B-01002 B-01002
Auxiliary burner Auxiliary Burner

Task Group Status: 7/24/2016 8:46 AM

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 7 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

010-PI-6151 5 BarG 7/24/2016 SUWARDY,


8:46:49 AM SYAHMUDIN
(1021775)

B-01002
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-6152 0.3 BarG 7/24/2016 SUWARDY,
8:46:50 AM SYAHMUDIN
(1021775)

B-01002
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
R-01003-SP R-01003-SP
Pre Reformer R-01003 (Scan Point). Please scan to Pre-Reformer (Scan Point)
unlock.

Task Group Status: Tag Scanned 7/24/2016 8:50 AM

R-01003 R-01003
Pre Reformer Pre-Reformer

Task Group Status: Online 7/24/2016 8:50 AM


010-PI-1101 45 BarG 7/24/2016 SUWARDY,
8:50:44 AM SYAHMUDIN
(1021775)

R-01003
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-1153 40 BarG 7/24/2016 SUWARDY,
8:50:45 AM SYAHMUDIN
(1021775)

E-01012
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
CT-01001-SP CT-01001-SP
Force Draft fan CT-01001 (Scan Point). Please scan Force Draft Fan (Scan Poin
to unlock. t)

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 8 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Task Group Status: Tag Scanned 7/24/2016 8:51 AM

CT-01001 CT-01001
Force Draft fan Force Draft Fan

Task Group Status: 7/24/2016 8:51 AM


010-TI-1351 350 C 7/24/2016 SUWARDY,
8:51:06 AM SYAHMUDIN
(1021775)

CT-01001
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-PI-1351 40 BarG 7/24/2016 SUWARDY,
8:51:07 AM SYAHMUDIN
(1021775)

CT-01001
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-1352 6 BarG 7/24/2016 SUWARDY,
8:51:08 AM SYAHMUDIN
(1021775)

CT-01001
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
ECT-01001-01 A 7/24/2016 SUWARDY,
8:51:09 AM SYAHMUDIN
(1021775)

CT-01001
010-TI-8455 40 C Temperature 7/24/2016 SUWARDY,
- Low 8:51:11 AM SYAHMUDIN
(1021775)

CT-01001
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8456 40 C 7/24/2016 SUWARDY,
8:51:13 AM SYAHMUDIN

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 9 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

(1021775)

CT-01001
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8451 50 C 7/24/2016 SUWARDY,
8:51:14 AM SYAHMUDIN
(1021775)

CT-01001
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8453 50 C 7/24/2016 SUWARDY,
8:51:15 AM SYAHMUDIN
(1021775)

CT-01001
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8452 50 C 7/24/2016 SUWARDY,
8:51:16 AM SYAHMUDIN
(1021775)

CT-01001
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8454 50 C 7/24/2016 SUWARDY,
8:51:17 AM SYAHMUDIN
(1021775)

CT-01001
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-LG-8451 70 % 7/24/2016 SUWARDY,
8:51:18 AM SYAHMUDIN
(1021775)

CT-01001
Level Low : 6070 OPN - Level Low
Level Low! Please check and inform panelman if necessary.

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 10 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Level High : 6070 OPN - Level High


Level High! Please check and inform panelman if necessary.
GCT-01001-01A Auto 7/24/2016 SUWARDY,
8:51:19 AM SYAHMUDIN
(1021775)

CT-01001
010-TI-8458 40 C 7/24/2016 SUWARDY,
8:51:20 AM SYAHMUDIN
(1021775)

CT-01001
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8457 40 C 7/24/2016 SUWARDY,
8:51:21 AM SYAHMUDIN
(1021775)

CT-01001
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
FCT-01001-01 A 7/24/2016 SUWARDY,
8:51:23 AM SYAHMUDIN
(1021775)

CT-01001
010-PDI-8454 30 % 7/24/2016 SUWARDY,
8:51:25 AM SYAHMUDIN
(1021775)

CT-01001
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PT-8401 1.5 BarG 7/24/2016 SUWARDY,
8:51:27 AM SYAHMUDIN
(1021775)

CT-01001
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-8451 0 BarG 7/24/2016 SUWARDY,
8:51:27 AM SYAHMUDIN
(1021775)

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 11 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

CT-01001
010-PI-8452 10 BarG 7/24/2016 SUWARDY,
8:51:28 AM SYAHMUDIN
(1021775)

CT-01001
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-8453 30 BarG 6060 OPN - 7/24/2016 SUWARDY,
Pressure Low 8:51:29 AM SYAHMUDIN
(1021775)

CT-01001
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-8457 0.1 BarG 7/24/2016 SUWARDY,
8:51:32 AM SYAHMUDIN
(1021775)

CT-01001
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-SI-8401 840 RPM 7/24/2016 SUWARDY,
8:51:37 AM SYAHMUDIN
(1021775)

CT-01001
CT-01002-SP CT-01002-SP
Induced Draft fan CT-01002 (Scan Point). Please sc Induce Draft Fan (Scan Poi
an to unlock. nt)

Task Group Status: Tag Scanned 7/24/2016 8:51 AM

CT-01002 CT-01002
Induced Draft fan Induce Draft Fan

Task Group Status: 7/24/2016 8:51 AM


010-TI-1751 380 C 7/24/2016 SUWARDY,
8:51:52 AM SYAHMUDIN
(1021775)

CT-01002
Temperature Low : Temperature - Low

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 12 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Temperature Low! Please check and inform panelman if necessary.


Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-PI-1751 40 BarG 7/24/2016 SUWARDY,
8:51:53 AM SYAHMUDIN
(1021775)

CT-01002
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-1752 6 BarG 7/24/2016 SUWARDY,
8:51:54 AM SYAHMUDIN
(1021775)

CT-01002
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
ECT-01002-01 A 7/24/2016 SUWARDY,
8:51:55 AM SYAHMUDIN
(1021775)

CT-01002
010-TI-8556 40 C Temperature 7/24/2016 SUWARDY,
- Low 8:51:57 AM SYAHMUDIN
(1021775)

CT-01002
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8555 40 C 7/24/2016 SUWARDY,
8:51:59 AM SYAHMUDIN
(1021775)

CT-01002
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8551 50 C 7/24/2016 SUWARDY,
8:52:06 AM SYAHMUDIN
(1021775)

CT-01002
Temperature Low : Temperature - Low

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 13 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Temperature Low! Please check and inform panelman if necessary.


Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8553 50 C 7/24/2016 SUWARDY,
8:52:08 AM SYAHMUDIN
(1021775)

CT-01002
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8552 50 C Temperature 7/24/2016 SUWARDY,
- Low 8:52:09 AM SYAHMUDIN
(1021775)

CT-01002
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8554 50 C 7/24/2016 SUWARDY,
8:52:11 AM SYAHMUDIN
(1021775)

CT-01002
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-LG-8551 70 % 7/24/2016 SUWARDY,
8:52:13 AM SYAHMUDIN
(1021775)

CT-01002
Level Low : 6070 OPN - Level Low
Level Low! Please check and inform panelman if necessary.
Level High : 6070 OPN - Level High
Level High! Please check and inform panelman if necessary.
GCT-01002-01A Auto 7/24/2016 SUWARDY,
8:52:14 AM SYAHMUDIN
(1021775)

CT-01002
010-TI-8558 40 C 7/24/2016 SUWARDY,
8:52:15 AM SYAHMUDIN
(1021775)

CT-01002
Temperature Low : Temperature - Low

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 14 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Temperature Low! Please check and inform panelman if necessary.


Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
010-TI-8557 40 C 7/24/2016 SUWARDY,
8:52:16 AM SYAHMUDIN
(1021775)

CT-01002
Temperature Low : Temperature - Low
Temperature Low! Please check and inform panelman if necessary.
Temperature High : Temperature - High
Temperature High! Please check and inform panelman if necessary.
FCT-01002-01 A 7/24/2016 SUWARDY,
8:52:17 AM SYAHMUDIN
(1021775)

CT-01002
010-PDI-8554 0 % 7/24/2016 SUWARDY,
8:52:19 AM SYAHMUDIN
(1021775)

CT-01002
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PT-8501 1.5 BarG 7/24/2016 SUWARDY,
8:52:23 AM SYAHMUDIN
(1021775)

CT-01002
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-8551 0 BarG 6060 OPN - 7/24/2016 SUWARDY,
Pressure Low 8:52:24 AM SYAHMUDIN
(1021775)

CT-01002
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-8552 10 BarG 7/24/2016 SUWARDY,
8:52:26 AM SYAHMUDIN
(1021775)

CT-01002
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 15 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Pressure High! Please check and inform panelman if necessary.


010-PI-8553 30 BarG 7/24/2016 SUWARDY,
8:52:27 AM SYAHMUDIN
(1021775)

CT-01002
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-8557 1 BarG 6040 OPN - 7/24/2016 SUWARDY,
Pressure 8:52:30 AM SYAHMUDIN
High (1021775)

CT-01002
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
Pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-SI-8501 865 RPM 7/24/2016 SUWARDY,
8:52:32 AM SYAHMUDIN
(1021775)

CT-01002
D-01501-SP D-01501-SP
Stripper D-01501 (Scan Point) contain of D-01501, Stripper (Scan Point)
E-01007, F-01004, F-01007 and E-01005. Please scan
to unlock.

Task Group Status: Tag Scanned 7/24/2016 8:37 AM

D-01501 D-01501
stripper Stripper

Task Group Status: 7/24/2016 8:37 AM


010-LG-3351 70 % 7/24/2016 SUWARDY,
8:37:53 AM SYAHMUDIN
(1021775)

D-01501
Level Low : 6070 OPN - Level Low
Level Low! Please check and inform panelman if necessary.
Level High : 6070 OPN - Level High
Level High! Please check and inform panelman if necessary.
G-01503A G-01503A
Condensate pump A condensate pump A

Task Group Status: Standby 7/24/2016 8:37 AM


015-PI-3351A BarG

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 16 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

G-01503A
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
015-PI-3352A BarG

G-01503A
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
lube oil level %

G-01503A
Level Low : 6070 OPN - Level Low
Level Low! Please top up lube oil
G-01503B G-01503B
Condensate pump B condensate pump B

Task Group Status: Running 7/24/2016 8:37 AM


015-PI-3351B 2 BarG 7/24/2016 SUWARDY,
8:37:58 AM SYAHMUDIN
(1021775)

G-01503B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
015-PI-3352B 8 BarG 7/24/2016 SUWARDY,
8:37:59 AM SYAHMUDIN
(1021775)

G-01503B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
lube oil level 70 % 7/24/2016 SUWARDY,
8:38:00 AM SYAHMUDIN
(1021775)

G-01503B
Level Low : 6070 OPN - Level Low
Level Low! Please top up lube oil
E-01007 E-01007

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 17 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Demin water pre heater Demin Water Pre Heater

Task Group Status: 7/24/2016 8:38 AM


010-LI-3252 45 % 7/24/2016 SUWARDY,
8:38:02 AM SYAHMUDIN
(1021775)

E-01007
Level Low : 6070 OPN - Level Low
Level Low! Please check and inform panelman if necessary.
Level High : 6070 OPN - Level High
Level High! Please check and inform panelman if necessary.
F-01004 F-01004
Final separator Final Separator

Task Group Status: 7/24/2016 8:38 AM


010-LI-3253 45 % 7/24/2016 SUWARDY,
8:38:04 AM SYAHMUDIN
(1021775)

F-01004
Level Low : 6070 OPN - Level Low
Level Low! Please check and inform panelman if necessary.
Level High : 6070 OPN - Level High
Level High! Please check and inform panelman if necessary.
F-01007 F-01007
process condensate intermediate tank Process Condensate Interme
diate Tank
Task Group Status: 7/24/2016 8:38 AM
010-LI-3352 75 % 7/24/2016 SUWARDY,
8:38:05 AM SYAHMUDIN
(1021775)

F-01007
Level Low : 6070 OPN - Level Low
Level Low! Please check and inform panelman if necessary.
Level High : 6070 OPN - Level High
Level High! Please check and inform panelman if necessary.
G-01002A G-01002A
Process condensate pump A Process condensate pump A

Task Group Status: Standby 7/24/2016 8:38 AM


010-PI-8251A BarG

G-01002A
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 18 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

pressure High : 6040 OPN - Pressure High


Pressure High! Please check and inform panelman if necessary.
010-PI-8252A BarG

G-01002A
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
lube oil level %

G-01002A
Level Low : 6070 OPN - Level Low
Level Low! Please top up lube oil
cooling water

G-01002A
G-01002B G-01002B
process condensate pump B Process condensate pump B

Task Group Status: Running 7/24/2016 8:38 AM


010-PI-8251B 28 BarG 7/24/2016 SUWARDY,
8:38:09 AM SYAHMUDIN
(1021775)

G-01002B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-8252B 68 BarG 7/24/2016 SUWARDY,
8:38:11 AM SYAHMUDIN
(1021775)

G-01002B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
lube oil level 70 % 7/24/2016 SUWARDY,
8:38:12 AM SYAHMUDIN
(1021775)

G-01002B
Level Low : 6070 OPN - Level Low
Level Low! Please top up lube oil
cooling water OK 7/24/2016 SUWARDY,
8:38:13 AM SYAHMUDIN
(1021775)

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 19 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

G-01002B
E-01005 E-01005
Circulation water heater Circulation Water Heater

Task Group Status: 7/24/2016 8:38 AM


010-LI-3251 50 % 7/24/2016 SUWARDY,
8:38:15 AM SYAHMUDIN
(1021775)

E-01005
Level Low : 6070 OPN - Level Low
Level Low! Please check and inform panelman if necessary.
Level High : 6070 OPN - Level High
Level High! Please check and inform panelman if necessary.
D-01001-SP D-01001-SP
Saturator D-01001 (Scan Point). This scan point co Saturator (Scan Point)
ntain of D-01001, G-01001A/B and F-01503. Please s
can to unlock.

Task Group Status: Tag Scanned 7/24/2016 8:40 AM

D-01001 D-01001
Saturator Saturator

Task Group Status: Online 7/24/2016 8:40 AM


010-LG-0351 50 % 7/24/2016 SUWARDY,
8:40:58 AM SYAHMUDIN
(1021775)

D-01001
Level Low : 6070 OPN - Level Low
Level Low! Please check and inform panelman if necessary.
Level High : 6070 OPN - Level High
Level High! Please check and inform panelman if necessary.
G-01001A G-01001A
Circulation water pump A Saturator circulation wate
r pump A
Task Group Status: Standby 7/24/2016 8:41 AM
010-PI-0352A BarG

G-01001A
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-0353A BarG

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 20 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

G-01001A
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
lube oil level %

G-01001A
Level Low : 6070 OPN - Level Low
Level Low! Please top up lube oil
cooling water

G-01001A
G-01001B G-01001B
Circulation water pump B Saturator circulation wate
r pump B
Task Group Status: Running 7/24/2016 8:41 AM
010-PI-0352B 50 BarG 7/24/2016 SUWARDY,
8:41:03 AM SYAHMUDIN
(1021775)

G-01001B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
010-PI-0353B 52 BarG 7/24/2016 SUWARDY,
8:41:04 AM SYAHMUDIN
(1021775)

G-01001B
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
lube oil level 70 % 7/24/2016 SUWARDY,
8:41:05 AM SYAHMUDIN
(1021775)

G-01001B
Level Low : 6070 OPN - Level Low
Level Low! Please top up lube oil
cooling water OK 7/24/2016 SUWARDY,
8:41:06 AM SYAHMUDIN
(1021775)

G-01001B
F-01503 F-01503

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 21 of 22
Completed Procedure Report P2 U-100/U-1500 Day 10am

Blow down drum Blow Down Vessel

Task Group Status: 7/24/2016 8:41 AM


015-PI-3551 5.6 BarG 7/24/2016 SUWARDY,
8:41:08 AM SYAHMUDIN
(1021775)

F-01503
Pressure Low : 6060 OPN - Pressure Low
Pressure Low! Please check and inform panelman if necessary.
pressure High : 6040 OPN - Pressure High
Pressure High! Please check and inform panelman if necessary.
No

Decision: False 7/24/2016 8:41 AM


Justify reason
Special task : Abnormal

Abnormal Condition

Decision: False 7/24/2016 8:41 AM

Copyright © 1999-2017 Invensys Systems, Inc. Report Date: 1/21/2017 2:16:53 PM Page 22 of 22