Sunteți pe pagina 1din 6

Power Cable

Low Voltage

XLPE Insulated
Power And Control Cables

Catalogue

PT KABELINDO MURNI Tbk


Wire and Cable Manufacturer
Power Cables
Catalogue
XLPE Low Voltage InsulaƟŽn
Power And Control Cables

Making The ConnecƟŽn


XLPE INSULATED

POWER AND CONTROL CABLES

Page
SUMMARY

4-5

Cu/XLPE 0.6/1 kV (N2XA) 6

Cu/XLPE/PVC 0.6/1 kV (N2XY) 7 - 11

Cu/XLPE/PVC 0.6/1 kV Control Cable (N2XY) 12 - 15

Cu/XLPE/SWA/PVC 0.6/1 kV (N2XRGbY) 16 - 20

Cu/XLPE/SWA/PVC 0.6/1 kV Control Cable (N2XRGbY) 21 - 24

Cu/XLPE/SFA/PVC 0.6/1 kV (N2XFGbY) 25 - 28

Cu/XLPE/SFA/PVC 0.6/1 kV Control Cable (N2XFGbY) 29 - 32

Cu/XLPE/DSTA/PVC 0.6/1 kV (N2XBY) 33 - 37

Cu/XLPE/DSTA/PVC 0.6/1 kV Control Cable (N2XBY) 38 - 41

Cu/XLPE/CWS/PVC 0.6/1 kV (N2XCY) 42 - 46

Cu/XLPE/CWS/PVC 0.6/1 kV Control Cable (N2XCY) 47 - 50

Cu/XLPE/CTS/PVC 0.6/1 kV (N2XSY) 51 - 55

Cu/XLPE/CTS/PVC 0.6/1 kV Control Cable (N2XSY) 56 - 59

60 - 66

67

Drum Dimension And Handling 69

Notes

sales@kabelindo.co.id 2
Introduction of company

The Company’s history was marked by the founding of PT. Kabel Indonesia (Kabelindo) in 1972,

the Company’s ownership was transferred to Indonesians and names was changed to PT. Kabelindo

Murni.

We produce and markets Bare Conductor, Low Voltage Cable, Medium Cable, Instrument Cable,

Control Cable, Telephone Cable, Fire Resistant Cable and Flame Retardant Cable. The quality assurance

of the products is the main issue that the Company emphasizes. The electrical cables produced by the

To Support the Company’s commitment to quality, the Company has the ISO 9001:2015 ISO 45001 :

3 www.kabelindo.co.id
GENERAL INFORMATION

Copper Conductor Resistance SNI IEC 60228

Class 1, 2 Class 5
Conductor Size DC. Resistance AC. Resistance AC. Resistance DC. Resistance
at 20 °C at 70 °C at 90 °C at 20 °C

sq.mm Madž͘;ёͬŬŵͿ Madž͘;ёͬŬŵͿ Madž͘;ёͬŬŵͿ Madž͘;ёͬŬŵͿ


1.5 12.1 14.484 15.43 13.3

2.5 7.41 8.870 9.45 7.98

4 4.61 5.518 5.88 4.95

6 3.08 3.687 3.93 3.30

10 1.83 2.191 2.33 1.91

16 1.15 1.377 1.47 1.21

25 0.727 0.870 0.927 0.780

35 0.524 0.627 0.669 0.554

50 0.387 0.463 0.494 0.386

70 0.268 0.321 0.342 0.272

95 0.193 0.231 0.247 0.206

120 0.153 0.183 0.196 0.161

150 0.124 0.148 0.160 0.129

185 0.099 0.119 0.128 0.106

240 0.075 0.093 0.099 0.080

300 0.060 0.075 0.080 0.064

400 0.047 0.058 0.064 0.049

500 0.037 0.045 0.051 0.038

630 0.028 0.041 0.042 0.029

are exerted on the tray.

designed and produced to pass direct burial test requirements

3. XLPE jacket is a very stable material against a wide range of chemicals.

sales@kabelindo.co.id 4
4. Recommended minimum bending radius of cables :

Minimum bending radius Minimum bending radius


of installed
10 x Diameter Cable 8 x Diameter Cable

Bend Radius

Bend Radius

enclosure shall be arranged so that all line conductors and the neutral conductor, if any, and the

ferrous material.

Due to the wide range of cables in the catalogue, it is advisable, when ordering, to provide as much

3. Number of cores.
4. Conductor size.
5. Colour of outer sheath.
6. Length of cables required and individual drum lengths.

ͻsŝƐƵĂů
ͻŝŵĞŶƐŝŽŶ
ͻŽŶĚƵĐtor resistance
ͻAC voltage test

All information is believed to be accurate at the time issue, Information contained in this catalogue may be
subject to change without notice

5 www.kabelindo.co.id

S-ar putea să vă placă și