Sunteți pe pagina 1din 75

Product Catalogue

Air Conditioner Solutions 2017


Product Categories

INTRODUCTION
D
DVMS
VRF

VMS O
DVM S Commercial

OUTDOOR
UTDOOR U
With its wide range of capacities and advanced
technology, the DVM system is the perfect

UNITS
cooling and heating solution for any type

NITS
of space from high-rise buildings to small
commercial buildings.
DVM S DVM S Water DVM S Eco

DVM S INDOOR UNITS


Single split

CAC Light Commercial


This one-to-one system that links outdoor
and indoor units is the most suitable air solution
for individual businesses to manage their own

CAC
air-conditioning system in small and medium-
sized commercial buildings.

Commercial Air Conditioner

FJM
Multi split

FJM Residential
indoor units, the FJM system is ideal for
residential spaces with multiple rooms to

CONTROL SYSETM
Free Joint Multi

2017 Samsung Air Conditioning Solutions 1 2 www.samsung.com/business


INTRODUCTION
SAMSUNG
Product Types

D
DVMS
VMS O
OUTDOOR
UTDOOR U
UNITS
NITS
HEAT PUMP HEAT RECOVERY MODULAR CHILLER WALL MOUNTED TYPE CONSOLE TYPE

DVM S INDOOR UNITS


DVM S DVM S Eco DVM S HR DVM S Water DVM S Chiller
Neo Forte AR5000 Boracay Console

CASSETTE TYPE CEILING TYPE FLOOR STANDING TYPE

CAC
360 Cassette 4 Way Cassette 4 Way Cassette (600x600) 1 Way Cassette 2 Way Cassette
Ceiling Ceiling(Large) Concealed Packaged

FJM
DUCT TYPE HYDRO(HOT WATER) VENTILATION UNIT

CONTROL SYSETM
HSP Duct MSP Duct LSP Duct OAP Duct
50oC 80oC ERV Plus ERV

2017 Samsung Air Conditioning Solutions 3 4 www.samsung.com/business


DVM S

INTRODUCTION
THE WORLD’S LARGEST CAPACITY

DVM S
World’s Largest

DVMS OUTDOOR UNITS


Single Module
30HP

DVM S INDOOR UNITS


VRF technology supports zone control, enabling users to adjust individual climate settings to suit their personal

Samsung’s VRF system air conditioners offer instant temperature control, user-friendly installation and advanced

CAC
available on the market. This air conditioning system is ideal for various environments, including large
commercial and residential buildings.

such as:

The world's largest capacity.


design.

Improved heating performance.


environments.

FJM
Decrease energy consumption and costs with a dual inverter system featuring simultaneous
compressor operation for higher performance.

Flexible installation. Ease installation and reduce labor costs with a lightweight design, extended piping length, and
elevation support.

Year-round climate control. Enjoy a comfortable environment even in extreme climates with advanced temperature
control and rapid cooling and heating.

CONTROL SYSETM
Smart management. Monitor system performance effectively with convenient web-based data access and management
from anywhere.

Reliable performance and durability.


corrosion resistance.

2017 Samsung Air Conditioning Solutions 5 6 www.samsung.com/business


DVM S DVM S

INTRODUCTION
THE WORLD’S LARGEST CAPACITY SMART EFFICIENCY

World’s Largest Single Module – 30HP


Samsung DVM S 30HP is the world’s largest and most compact single

DVMS OUTDOOR UNITS


module VRF system. It is also powerful and its 30HP system. The addition of an innovative hybrid heat exchanger increases the heat exchange area while an

areas.
* Based on internal benchmark studies as at September 2015.

Hybrid Heat Exchanger Upper Fin

More choice of capacity, even less cost

30HP unit, so you can reduce the installation and management costs and save valuable space.
Wide slit

DVM S INDOOR UNITS


Lower Fin

Corrugate

Maximize heating and cooling capacity with a conveniently sized design DVM S has achieved superior EER which far surpasses Samsung conventional systems EER at all ranges. On
average, DVM S boasts 13%* higher EER than Samsung conventional systems.
the world’s largest heating and cooling capacity without increasing its size enabling businesses to use their space

CAC
DVM S
5

2
8HP 10HP 12HP 14HP 16HP 18HP 20HP 22HP 24HP 26HP 28HP 30HP

FJM
More usable space - no compromise
Its compact size leaves you plenty of extra space that can be used for other purposes without compromising on Class leading energy

compressor with vapour injection system. It gives you


powerful quick cooling with minimum energy consumption.

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 7 8 www.samsung.com/business
DVM S DVM S

INTRODUCTION
SMART EFFICIENCY & SMART MANAGEMENT SMART MANAGEMENT

Adaptive sine wave control Reduced commissioning time


Thanks to the ACM, the commissioning time for DVM S has shortened considerably down to 50 minutes, and

DVMS OUTDOOR UNITS


shield wiring for communication. testing results are automatically stored and reported.

Samsung Conventional DVM S

[A] [A]

[Hz] [Hz]

Fast

DVM S INDOOR UNITS


*Based on Samsung’s internal test results with comparison of selected Samsung’s conventional models. Individual test results may vary.

SMART MANAGEMENT checking


Samsung provides an easy to use, smart management system that makes life simple. With this web-based
system, you can immediately access data and easily manage it for unsurpassed convenience, any time, anywhere.

Auto commissioning and Management (ACM) - Optional


DVM S has a smart, web-based management system that facilitates self-diagnosis, auto commissioning, auto
management, and mobile data transmission, which users can easily access and monitor via the web-based tool. It
provides easy and convenient management as you can control the system with smart phone and/or tablet.

WiFi Monitoring System – Optional

CAC
With Samsung S-checker device, you can easily and conveniently monitor the DVM S through smart device such
as smart phone or tablet. With self-diagnosis mode, DVM S automatically monitors its operation status and
displays an error code in response to signs of abnormal operation. Users can then identify and address the issue
promptly.

Samsung Conventional DVM S

Serial port F1/F2 communication lines Wifi connection Check multiple outdoor
equipment simultaneously

FJM
Wireless
communication
S-Checker

Smart Phone

Tablet PC

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 9 10 www.samsung.com/business
DVM S DVM S

INTRODUCTION
IMPROVED HEATING PERFORMANCE AND HIGH ENERGY EFFICIENCY FLEXIBLE INSTALLATION

Easy access Limit power consumption with Before & after peak power-demand control

Thanks to the small opening on the outdoor unit, checking the outdoor peak-demand control Maximum amount of electric current

DVMS OUTDOOR UNITS


status and setting option is easy, because users don't need to remove To help businesses manage better power consumption Reduced amount
of electric current
the entire front cover. and related costs better, DVM S offers power-demand
Less Energy
Consumption
businesses want to block excessive and wasteful energy
usage. Before After

operation

delivers reliable heating and lower temperatures, while more intelligent defrost and snow detection offer more
precise operation, saving valuable energy and expenses. between indoor and outdoor units promotes easier and safer wiring work, because the outdoor unit protects itself

DVM S INDOOR UNITS


if the communication cable is mistakenly connected to a power terminal.

Flexible installation with extended pipe


length and elevation
comfort in frigid
conditions.

Intelligent defrost so individual indoor


units perform capacity connection control and automatic
refrigerant equalization for more balanced performance
considers between units.
not only conventional factors but also air resistance to
Smaller footprint and lighter weight
Conventional 30HP

CAC
intelligently judge the defrost operation. Precise defrost
judgment avoids unnecessary defrosting thanks to the partial
load and lower ambient temperature operation. Ultimately,
users can enjoy less energy waste and more continuous
heating time.
DVM S 30HP

Easy and safe wiring


economy. Non-polar communication between indoor and outdoor units makes wiring work much easier. This is also safer
since the outdoor unit will protect itself in case the communication cable is connected to a power terminal by
Reduce maintenance and energy costs with intercoolers mistake.

FJM
Optimized refrigerant distribution control
to Shell & Tube and Double Tube type intercoolers. The higher heat exchange rate means optimal distribution,
lowering maintenance and energy costs. DVM S compensates for the long piping distance between outdoor units and indoor units by providing balanced
refrigerant distribution. The individual indoor units perform capacity connection control and automatic
Heat Exchanger Performance 150% refrigerant balancing to ensure balanced performance between the units.
115%
Normal operation is possible even when communication
100% cables are not connected correctly
Auto pressure

CONTROL SYSETM
correction Non-polarity

Indoor unit A Indoor unit B


Outdoor unit
Double Tube Shell & Tube PHE Intercooler

2017 Samsung Air Conditioning Solutions 11 12 www.samsung.com/business


DVM S DVM S

INTRODUCTION
CORE TECHNOLOGY CORE TECHNOLOGY & SMART OPERATION

Samsung is dedicated to supporting comfortable living and working environments based on the strength of Quick Cooling and Heating
its technologies. With its robust design, DVM S delivers the reliability and durability that users need to ensure
With compressor speed acceleration and simultaneous starting, DVM S provides quick cooling and heating

DVMS OUTDOOR UNITS


consistent performance at all times.
performance.

Asymmetric Scroll Design Quick Start (Simultaneous Operation)


[HZ]
Fast Frequency Acceleration
[HZ]
Fast Heating Performance
33% Higher Heating
100 100

80 80
maximum performance. 60 60

40 40
DVM S Samsung Conventional
20 20
5sec 90sec 7min 9min 10min
Sequential compressing Contradictory compressing 0 0

Loss Discharge Conventional Cooling Mode Heating Mode

DVM S INDOOR UNITS


* Based on Samsung lab test

1 2 Loss
2 1
1 Suction
1 2 Auto Oil Balancing
Suction Suction
Samsung DVM S ensures stable and equal oil balancing without requiring an extra oil balancing pipe.
* No friction loss in the compressor, thanks to sequential suction and * Suction from two different sides and discharge through one can cause colli-
discharge. sion of refrigerant gas which results in friction loss in the compressor. Samsung Conventional

Dual Smart Inverter (DSI) System + Inverter Compressor


2Pipe + Inverter Compressor
3Pipe
The 3rd generation innovative system, Dual Smart System, adopts a dual inverter compressor system that *Balance Pipe is necessary

CAC
VAR VAR Peak power-demand control
VAR FIX

VAR FIX FIX FIX


To help businesses better manage power consumption and related costs, DVM S can control peak current and
power consumption. This is especially useful when electric supply is not enough or when you want to block
excessive energy usage.

Maximum amount of electric current

FJM
Reduced amount
of electric current
DDI System
Dual Digital Inverter Compressor 3rd Generation Vapor Injection
Wider operation range of BLDC motor Frequency (20~140Hz) Less Energy
High-pressure
Consumption
Refrigerant
Discharge

CONTROL SYSETM
Before After
Low-pressure
Refrigerant
Suction

2017 Samsung Air Conditioning Solutions 13 14 www.samsung.com/business


DVM S DVM S ECO

INTRODUCTION
SMART OPERATION

78.40 Pa
High external static pressure
wide range of homes and small businesses. It is available in capacities of 4HP to 14HP, option of Single Phase for
To properly deal with unexpected and varying installation conditions, DVM S is

DVMS OUTDOOR UNITS


4HP to 6HP.
designed to manage high external static pressures up to 78.40pa.

Corrosion and frost resistance

formation to provide consistent heating performance. An anti-corrosive coating also helps the units to resist

DVM S INDOOR UNITS


corrosion from the elements.

Hydrophilic layer acrylic


resin+surfactant
Anti-corrosive
layer epoxy acrylic Flexible Piping Design
Raw aluminum
material
allows for a level difference of up to 50m between indoor and outdoor units, and a pipe length up to 160m. This

Corrosion resistant finishing on heat exchanger fin

CAC
Quiet operation for night time
DVM S has applied an operation control system to the outdoor fans to limit the maximum fan RPM and compressor
frequency to reduce noise during the night time. This option operates for 12 hours and reverts back to normal
settings in the morning so that residents can relax and rest peacefully with less distraction during the night.

FJM
The DVM S Eco has a 4 way piping system, with connections at

into many more places, including small and narrow spaces, and is
easier to install and maintain.

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 15 16 www.samsung.com/business
DVM S ECO DVM S WATER

INTRODUCTION
Control your cooling anywhere Temper the indoor environment with innovative water-based heating and
cooling technology
An optional Wi-Fi Kit lets you remotely control indoor units using a smartphone

DVMS OUTDOOR UNITS


App*. Anytime and anywhere you can turn them on and off, select the operating DVM S WATER is a high-capacity outdoor cooling and heating system, ideal for large buildings. Unique to other DVM
mode and temperature and utilize other functions. S models, the DVM S WATER air conditioning system uses water as its heat source, which connects to a cooling tower

performance despite changes in the surrounding environment. Its long piping and lightweight design also makes it
easy and economical to install almost anywhere.

features such as:


Samsung DVM S Eco includes an innovative Digital Inverter Better Performance
Compressor, an optimised heat exchanger with corrugated Increased energy savings. Save on energy consumption and costs with a dual inverter system and high-performance
compressors.

DVM S INDOOR UNITS


Ease installation and minimize effort with a lightweight design, extended piping length and
elevation support.

Convenient management. Monitor system performance effectively with convenient web-based data access and
management from anywhere.
Better Capacity
Premium comfort. Support comfortable living and working environments based on the combined strengths of various
technologies.

Corrugated Fin Inverter Scroll Compressor

Ultra-quiet operation

CAC
By producing less noise than conventional models, the DVM S Eco imposes fewer distractions on residential and
working environments. Its compact, unimposing design and specially shaped fan blades help reduce sound levels
up to 5 dB compared with Samsung conventional models, creating a more pleasant environment. Plus, its quiet
operation during the night time creates a restful environment with a reduced noise level of 2 - 8 dB.

FJM
Control your cooling anywhere - Optional
An optional Wi-Fi Kit lets you remotely control indoor units using a smartphone
App*. Anytime and anywhere you can turn them on and off, select the operating

CONTROL SYSETM
mode and temperature and utilize other functions.
eco-and budget conscious businesses. With these technologies, DVM S WATER boasts 8 percent higher EER than
*Available on iPhones and Android devices. A Wi-Fi connection is required.

11 percent higher rate.

2017 Samsung Air Conditioning Solutions 17 18 www.samsung.com/business


DVM S WATER DVM CHILLER

INTRODUCTION
Easy to move and install modular design
The third-generation innovative system, DDI, adopts a dual inverter compressor system. Both inverter Its modular design and compact size reduce the time,

DVMS OUTDOOR UNITS


compressors operate simultaneously, providing compressor longevity and balanced oil distribution for quick cost and effort to transport, move and install it on site.
cooling and heating to save energy and the environment. Plus, the upgraded vapor injection system increases

Independent cooling and heating


Easily Increase Performance & Save Space
operate each indoor unit. This means users can set different temperatures for various spaces at the same time,
heating some rooms or areas of the building, while cooling others.
maintenance costs and frees up valuable space,
while expanding overall capacity.

DVM S INDOOR UNITS


Simply expand capacity on demand

expand capacity from 12 to 320 ton in various ways to optimize energy and space savings or a balance of both.

Work Silently at Night


A Night Silent Mode means it operates at 3 different levels
and works silently at night. It adjusts the speed of the
compressors and fans, so they supply the required cooling,
but provide a better sound performance.
Decreased maintenance and energy costs

CAC
Water
DVM S WATER features advanced PHE technology, which improves
Powerful Heating Performance
while maintenance and energy costs.

Refrigerant

Water Refrigerant

Simplify installation with a cost-saving, adaptable design

FJM
communication between indoor and outdoor units promotes easier, safer wiring work, because the outdoor unit
protects itself if the communication cable is mistakenly connected to a power terminal. Powerful Heating Performance

Wide Temperature Range of Operation


Economical design and setup
50

Cooling -15oC ~ 48oC 40


At 22HP, the large-unit capacity of DVM S WATER facilitates o
48 C
Heating -25oC ~ 43oC 30 o
economical installation with a smaller footprint and lighter weight 43 C
20
– an ideal solution for larger buildings. ~
~

CONTROL SYSETM
10
o
0 -15 C o
-25 C
-10

Temperature o Cooling Heating

2017 Samsung Air Conditioning Solutions 19 20 www.samsung.com/business


DVM CHILLER DVM S HR

INTRODUCTION
PREMIUM HEAT RECOVERY

Heat environments effortlessly and continuously for ultimate comfort


The DVM Chiller's advanced technology delivers a consistently

DVMS OUTDOOR UNITS


higher performance and reduces wasted energy. It Evaporative Condenser
for reliable warmth and comfort. In addition, it supports agile operation through simultaneous cooling and heating.

Non-stop heating
DVM S HR can operate continuously in heating mode with
Energy saving operation(ESEER)
Inverter Scroll Compressor (SISC)

rotational defrost operation. Because the heating mode


runs for a longer period of time, users can enjoy a warmer
Various modes for different types of operational requirements
and more pleasant environment.

DVM S INDOOR UNITS


Rotational Operation

Simultaneous cooling and heating


Rotational Operation

Low Season Low Season 2 High Season Peak Season STEP 0 : Normal Heating Operation STEP 3 : Non-stop Heating Operation
Single outdoor units can operate all indoor
units in both cooling and heating mode.
They can also simultaneously operate
in cooling and heating mode, when
necessary, providing more operational Heating Heating Heating Heating Heating Defrosting
freedom.
STEP 1 : Non-stop Heating Operation STEP 2 : Non-stop Heating Operation

Centrally control all systems


To maximize operational convenience and the value of your existing units, an integrated control system lets you
centrally manage both outdoor and indoor units, such as the DVM chiller, VRF, and Air Side equipment.
Heating Defrosting Heating Defrosting Heating Heating

CAC
Fine-tuned control

sub-cooler. Improved performance and reduced noise create a pleasant temperature controlled environment.

Heating
Heating operation for
indoor environments where
heating load occurs due to
the outdoor environment.

FJM
Cooling
Cooling operation for
indoor environments
where cooling load oc-
curs all year round due
to devices and lighting
that generate heat.

CONTROL SYSETM
Recommended
Sites
Hotel Hospital

2017 Samsung Air Conditioning Solutions 21 22 www.samsung.com/business


MCU

INTRODUCTION
MODE CONTROL UNIT

MCU indoor/outdoor unit compatibility table


DVM S
OUTDOOR UNITS

DVMS OUTDOOR UNITS


SPECIFICATION

Outdoor Unit MCU Indoor Unit

MCU-S6NEE1N
MCU-S4NEE1N
AM****N****
MCU-S4NEE2N
MCU-S2NEK1N

Model Description

Below 6 indoor units, below 56 kW


MCU-S6NEE1N

Below 4 indoor units, below 56 kW


MCU-S4NEE1N
MCU Kit

Below 2 large capacity indoor unit, be-


MCU-S4NEE2N

Below 2 indoor units, below 28 kW


MCU-S2NEK1N

2017 Samsung Air Conditioning Solutions 23 24 www.samsung.com/business


DVM S DVM S

INTRODUCTION
COMBINATION TABLE COMBINATION TABLE

STANDARD COMBINATION (ENERGY SAVING) COMPACT COMBINATION (SPACE SAVING)


System Model System Model

DVMS OUTDOOR UNITS


Single No. of Capactity of Single Unit (HP) Single No. of Capactity of Single Unit (HP)
Module Modules Module Modules
8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP 22 HP 24 HP 26 HP 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP 22 HP 24 HP 26 HP
8 AM080FXVAGH/TK 1 1 8 AM080FXVAGH/TK 1 1
10 AM100FXVAGH/TK 1 1 10 AM100FXVAGH/TK 1 1
12 AM120FXVAGH/TK 1 1 12 AM120FXVAGH/TK 1 1
14 AM140FXVAGH/TK 1 1 14 AM140FXVAGH/TK 1 1
16 AM160FXVAGH/TK 1 1 16 AM160FXVAGH/TK 1 1
18 AM180FXVAGH/TK 1 1 18 AM180FXVAGH/TK 1 1
20 AM200FXVAGH/TK 1 1 20 AM200FXVAGH/TK 1 1

DVM S INDOOR UNITS


22 AM220FXVAGH/TK 1 1 22 AM220FXVAGH/TK 1 1
24 AM240HXVAGH/TK 1 1 24 AM240HXVAGH/TK 1 1
26 AM260HXVAGH/TK 1 1 26 AM260HXVAGH/TK 1 1
28 AM280HXVAGH1TK 1 1 1 28 AM280HXVAGH1TK 1 1
30 AM300HXVAGH1TK 2 1 1 30 AM300HXVAGH1TK 2 1 1
32 AM320HXVAGH1TK 2 1 1 32 AM320HXVAGH1TK 2 1 1
34 AM340HXVAGH1TK 2 1 1 34 AM340HXVAGH1TK 2 1 1
36 AM360HXVAGH1TK 2 1 1 36 AM360HXVAGH2TK 2 1 1
38 AM380HXVAGH1TK 2 1 1 38 AM380HXVAGH2TK 2 1 1
40 AM400HXVAGH1TK 2 1 1 40 AM400HXVAGH1TK 2 1 1
42 AM420HXVAGH1TK 2 1 1 42 AM420HXVAGH1TK 2 1 1

CAC
44 AM440HXVAGH1TK 2 2 44 AM440HXVAGH1TK 2 2
46 AM460HXVAGH1TK 3 2 1 46 AM460HXVAGH2TK 2 1 1
48 AM480HXVAGH1TK 3 1 1 1 48 AM480HXVAGH2TK 2 1 1
50 AM500HXVAGH1TK 3 1 1 1 50 AM500HXVAGH2TK 2 1 1
52 AM520HXVAGH1TK 3 1 1 1 52 AM520HXVAGH2TK 2 2
54 AM540HXVAGH1TK 3 1 1 1 54 AM540HXVAGH1TK 3 1 1 1
56 AM560HXVAGH1TK 3 1 2 56 AM560HXVAGH1TK 3 1 2
58 AM580HXVAGH1TK 3 1 2 58 AM580HXVAGH2TK 3 1 1 1
60 AM600HXVAGH1TK 3 1 2 60 AM600HXVAGH2TK 3 1 1 1

FJM
62 AM620HXVAGH1TK 3 1 2 62 AM620HXVAGH2TK 3 1 1 1
64 AM640HXVAGH1TK 3 1 2 64 AM640HXVAGH2TK 3 1 2
66 AM660HXVAGH1TK 3 3 66 AM660HXVAGH1TK 3 3
68 AM680HXVAGH1TK 4 2 2 68 AM680HXVAGH2TK 3 2 1
70 AM700HXVAGH1TK 4 1 1 2 70 AM700HXVAGH2TK 3 2 1
72 AM720HXVAGH1TK 4 1 1 2 72 AM720HXVAGH2TK 3 1 1 1
74 AM740HXVAGH1TK 4 1 1 2 74 AM740HXVAGH2TK 3 1 2

CONTROL SYSETM
76 AM760HXVAGH1TK 4 1 1 2 76 AM760HXVAGH2TK 3 1 2
78 AM780HXVAGH1TK 4 1 3 78 AM780HXVAGH2TK 3 3
80 AM800HXVAGH1TK 4 1 3 80 AM800HXVAGH1TK 4 1 3

2017 Samsung Air Conditioning Solutions 25 26 www.samsung.com/business


DVM S DVM S

INTRODUCTION
COMBINATION TABLE SPECIFICATION

COOLING ONLY COMBINATION


DVM S Standard
System Model

DVMS OUTDOOR UNITS


Model Code AM080FXVAGH/TK AM100FXVAGH/TK AM120FXVAGH/TK
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50

Single No. of Capactity of Single Unit (HP) HP 8.00 10.00 12.00


Module Modules 8 HP 10 HP 12 HP 14 HP 16 HP 18 HP 20 HP 22 HP 24 HP 26 HP 28 HP 30 HP
Capacity Cooling [kW] 22.40 28.00 33.60
Cooling [Btu/hr] 76,400 95,500 114,600

8 AM080MXVAGC/TS 1 1 Power Input Cooling [kW] 5.00 6.80 8.40


Cooling [kW] 8.00 10.90 13.50
10 AM100MXVAGC/TS 1 1 Current Input MCA [A] 18.00 (MCA) 21.10 (MCA) 25.00 (MCA)

12 1 1
MFA [A]
AM120MXVAGC/TS Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW]
25.00
4.48
32.00
4.12
32.00
4.00

14 AM140MXVAGC/TS 1 1 Compressor
Type SSC Scroll x 1 SSC Scroll x 1 SSC Scroll x 1
Output [kW x n] (4.96) (6.39) (6.39)
16 AM160MXVAGC/TS 1 1 Model Name DS-GB052FAVASG x 1 DS-GB066FAVBSG x 1 DS-GB066FAVBSG x 1
Type
18 AM180MXVAGC/TS 1 1 Output x n [W]
Propeller
400.0 x 1
Propeller
400.0 x 1
Propeller
400.0 x 1

20 AM200MXVAGC/TS 1 1 Fan Air Flow Rate [CMM]


External Static Pressure [mmAq]
170 170 220
8.00 8.00 8.00
22 AM220MXVAGC/TS 1 1

DVM S INDOOR UNITS


External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm]
24 AM240MXVAGC/TS 1 1 Liquid Pipe [Φ, inch]
9.52
3/8"
9.52
3/8"
12.70
1/2"

26 AM260MXVAGC/TS 1 1 Piping
Connections
Gas Pipe [Φ, mm]
Gas Pipe [Φ, inch]
19.05 22.22 28.58
3/4" 7/8" 1 1/8"
28 AM280MXVAGC/TS 1 1 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m]
30 1 1
110.0 110.0 110.0
AM300MXVAGC/TS Sound Pressure [dB(A)] 57.0 58.0 62.0
Sound
32 AM320MXVAGC/TS 2 1 1 Sound Power [dB(A)]
Net Weight [kg]
77.0
184.5
79.0
184.5
81.0
184.5

34 AM340MXVAGC/TS 2 1 1 External
Dimension
Shipping Weight [kg] 200.5 200.5 200.5
Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 880 x 1,695 x 765 880 x 1,695 x 765
36 AM360MXVAGC/TS 2 1 1 Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 948 x 1,887 x 832 948 x 1,887 x 832
Operating
38 AM380MXVAGC/TS 2 1 1 Temp. Range
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0

40 AM400MXVAGC/TS 2 1 1
42 AM420MXVAGC/TS 2 1 1
44 AM440MXVAGC/TS 2 2
46 AM460MXVAGC/TS 2 1 1
48 AM480MXVAGC/TS 2 1 1 DVM S Standard

CAC
Model Code AM140FXVAGH/TK AM160FXVAGH/TK AM180FXVAGH/TK
50 AM500MXVAGC/TS 2 1 1 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50

52 AM520MXVAGC/TS 2 1 1 Capacity
HP
Cooling [kW]
14.00
40.00
16.00
45.00
18.00
50.40

54 AM540MXVAGC/TS 2 1 1 Cooling [Btu/hr] 136,500 153,500 172,000


Power Input Cooling [kW] 8.90 11.00 12.88
56 AM560MXVAGC/TS 2 1 1 Cooling [kW] 14.30 17.60 20.70

58 AM580MXVAGC/TS 2 1 1 Current Input MCA [A]


MFA [A]
25.00 (MCA)
32.00
32.00 (MCA)
40.00
39.10 (MCA)
50.00

60 AM600MXVAGC/TS 2 2 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 4.49 4.09 3.91
Type SSC Scroll x 1 SSC Scroll x 2 SSC Scroll x 2
62 AM620MXVAGC/TS 3 1 1 1 Compressor Output [kW x n] (6.13) (4.96x2) (6.39x2)

64 AM640MXVAGC/TS 3 1 1 1 Model Name


Type
DS-GB066FAVASG x 1
Propeller
DS-GB052FAVASG x 2
Propeller
DS-GB066FAVBSG x 2
Propeller

66 AM660MXVAGC/TS 3 1 1 1 Output x n [W] 620.0 x 2 620.0 x 2 620.0 x 2


Fan Air Flow Rate [CMM] 260 260 290
68 AM680MXVAGC/TS 3 1 1 1

FJM
External Static Pressure [mmAq] 8.00 8.00 8.00

70 AM700MXVAGC/TS 3 1 1 1 External Static Pressure [Pa]


Liquid Pipe [Φ, mm]
78.45
12.70
78.45
12.70
78.45
15.88

72 AM720MXVAGC/TS 3 1 1 1 Liquid Pipe [Φ, inch] 1/2" 1/2" 5/8"


Piping Gas Pipe [Φ, mm] 28.58 28.58 28.58
74 AM740MXVAGC/TS 3 2 1 Connections Gas Pipe [Φ, inch] 1 1/8" 1 1/8" 1 1/8"

76 3 1 1 1
Installation Limitation [Max Length] [m]
AM760MXVAGC/TS
200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0

78 AM780MXVAGC/TS 3 1 1 1 Sound
Sound Pressure [dB(A)]
Sound Power [dB(A)]
61.0
81.0
63.0
83.0
64.0
86.0
80 AM800MXVAGC/TS 3 1 1 1 Net Weight [kg] 233.0 276.0 298.0
External Shipping Weight [kg] 252.0 295.0 317.0
82 AM820MXVAGC/TS 3 1 2 Dimension Net Dimensions (WxHxD) [mm] 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765

CONTROL SYSETM
84 AM840MXVAGC/TS 3 1 2
Shipping Dimensions (WxHxD) [mm] 1,363 x 1,887 x 832 1,363 x 1,887 x 832 1,363 x 1,887 x 832
Operating
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
86 AM860MXVAGC/TS 3 1 2 Temp. Range

88 AM880MXVAGC/TS 3 1 2 * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m.
90 AM900MXVAGC/TS 3 3 2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 27 28 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S Standard DVM S Standard

DVMS OUTDOOR UNITS


Model Code AM200FXVAGH/TK AM220FXVAGH/TK AM240HXVAGH/TK Model Code AM320HXVAGH1TK AM340HXVAGH1TK AM360HXVAGH1TK
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 20.00 22.00 24.00 HP 32.00 34.00 36.00
Capacity Cooling [kW] 56.00 61.60 67.20 Capacity Cooling [kW] 89.60 95.20 101.60
Cooling [Btu/hr] 191,100 210,200 229,300 Cooling [Btu/hr] 305,700 324,800 346,700
Power Input Cooling [kW] 15.19 17.35 17.10 Power Input Cooling [kW] 23.59 25.75 26.25
Cooling [kW] 24.40 27.80 26.83 Cooling [kW] 37.90 41.30 42.10
Current Input MCA [A] 42.50 (MCA) 44.50 (MCA) 60.50 (MCA) Current Input MCA [A] 67.50 (MCA) 69.50 (MCA) 69.50 (MCA)
MFA [A] 63.00 63.00 75.00 MFA [A] 90.00 90.00 90.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.69 3.55 3.93 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.80 3.70 3.87
Type SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 2 Type SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 3
Compressor Output [kW x n] (6.13x2) (6.39x2) (6.39x2) Compressor Output [kW x n] (6.39) + (6.39x2) (6.39) + (6.39x2) (6.39) + (6.39x2)
Model Name DS-GB066FAVASG x 2 DS-GB066FAVBSG x 2 DS-GB066FAVBSG x 2 Model Name DS-GB066FAVBSG x 3 DS-GB066FAVBSG x 3 DS-GB066FAVBSG x 3
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] 620.0 x 2 620.0 x 2 620.0 x 2 Output x n [W] 400.0 x 1 + 620.0 x 2 400.0 x 1 + 620.0 x 2 (620.0 x 2) x 2
Fan Air Flow Rate [CMM] 275 290 310 Fan Air Flow Rate [CMM] 220 + 290 220 + 290 255 + 290
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00

DVM S INDOOR UNITS


External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 15.88 15.88 15.88 Liquid Pipe [Φ, mm] 19.05 19.05 19.05
Liquid Pipe [Φ, inch] 5/8" 5/8" 5/8" Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4"
Piping Gas Pipe [Φ, mm] 28.58 28.58 34.92 Piping Gas Pipe [Φ, mm] 34.92 34.92 41.28
Connections Gas Pipe [Φ, inch] Connections Gas Pipe [Φ, inch]
1 1/8" 1 1/8" 1 3/8" 1 3/8" 1 3/8" 1 5/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 65.0 66.0 67.0 Sound Pressure [dB(A)] 67.0 67.0 67.0
Sound Sound
Sound Power [dB(A)] 87.0 89.0 91.0 Sound Power [dB(A)] 88.0 90.0 90.0
Net Weight [kg] 298.0 298.0 356.0 Net Weight [kg] 184.5 + 298.0 184.5 + 298.0 233.0 + 298.0
External Shipping Weight [kg] 317.0 317.0 371.0 External Shipping Weight [kg] 200.5 + 317.0 200.5 + 317.0 252.0 + 317.0
Dimension Net Dimensions (WxHxD) [mm] 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765 Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 + 1,295 x 1,695 x 765 880 x 1,695 x 765 + 1,295 x 1,695 x 765 (1,295 x 1,695 x 765) x 2
Shipping Dimensions (WxHxD) [mm] 1,363 x 1,887 x 832 1,363 x 1,887 x 832 1,363 x 1,887 x 832 Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 + 1,363 x 1,887 x 832 948 x 1,887 x 832 + 1,363 x 1,887 x 832 (1,363 x 1,887 x 832) x 2
Operating Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Cooling [ ℃]
Temp. Range Temp. Range

DVM S Standard DVM S Standard

CAC
Model Code AM260HXVAGH/TK AM280HXVAGH1TK AM300HXVAGH1TK Model Code AM380HXVAGH1TK AM400HXVAGH1TK AM420HXVAGH1TK
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 26.00 28.00 30.00 HP 38.00 40.00 42.00
Capacity Cooling [kW] 72.80 78.60 84.00 Capacity Cooling [kW] 106.60 112.80 117.60
Cooling [Btu/hr] 248,400 268,200 286,600 Cooling [Btu/hr] 363,700 384,900 401,300
Power Input Cooling [kW] 19.30 19.40 21.28 Power Input Cooling [kW] 28.35 28.20 32.54
Cooling [kW] 30.28 31.10 34.20 Cooling [kW] 45.40 44.58 52.20
Current Input MCA [A] 63.80 (MCA) 57.00 (MCA) 64.10 (MCA) Current Input MCA [A] 76.50 (MCA) 88.80 (MCA) 87.00 (MCA)
MFA [A] 75.00 75.00 90.00 MFA [A] 100.00 100.00 125.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.77 4.05 3.95 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.76 4.00 3.61
Type SSC Scroll x 2 SSC Scroll x 3 SSC Scroll x 3 Type SSC Scroll x 4 SSC Scroll x 3 SSC Scroll x 4
Compressor Output [kW x n] (6.76x2) (6.39) + (4.96x2) (6.39) + (6.39x2) Compressor Output [kW x n] (4.96x2) + (6.39x2) (6.39) + (6.76x2) (6.39x2) + (6.39x2)
Model Name DS-GB070FAVASG x 2 DS-GB066FAVBSG x 1 + DS-GB052FAVASG x 2 DS-GB066FAVBSG x 3 Model Name DS-GB052FAVASG x 2 + DS- GB066FAVBSG x 2 DS-GB066FAVBSG x 1 + DS- GB070FAVASG x 2 DS-GB066FAVBSG x 4
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] 620.0 x 2 400.0 x 1 + 620.0 x 2 400.0 x 1 + 620.0 x 2 Output x n [W] (620.0 x 2) x 2 (620.0 x 2) x 2 (620.0 x 2) x 2
Fan Air Flow Rate [CMM] 310 220 + 255 220 + 290 Fan Air Flow Rate [CMM] 255 + 290 255 + 310 290 x 2

FJM
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00
External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 19.05 19.05 19.05 Liquid Pipe [Φ, mm] 19.05 19.05 19.05
Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4" Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4"
Piping Gas Pipe [Φ, mm] 34.92 34.92 34.92 Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28
Connections Gas Pipe [Φ, inch] Connections Gas Pipe [Φ, inch] 1 5/8" 1 5/8" 1 5/8"
1 3/8" 1 3/8" 1 3/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 67.0 66.0 66.0 Sound Pressure [dB(A)] 68.0 68.0 69.0
Sound Sound
Sound Power [dB(A)] 91.0 85.0 87.0 Sound Power [dB(A)] 90.0 91.0 91.0
Net Weight [kg] 356.0 184.5 + 276.0 184.5 + 298.0 Net Weight [kg] 276.0 + 298.0 233.0 + 356.0 298.0 x 2
External Shipping Weight [kg] 371.0 200.5 + 295.0 200.5 + 317.0 External Shipping Weight [kg] 295.0 + 317.0 252.0 + 371.0 317.0 x 2
Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 + 1,295 x 1,695 x 765 880 x 1,695 x 765 + 1,295 x 1,695 x 765 Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2
1,295 x 1,695 x 765

CONTROL SYSETM
Shipping Dimensions (WxHxD) [mm] 1,363 x 1,887 x 832 948 x 1,887 x 832 + 1,363 x 1,887 x 832 948 x 1,887 x 832 + 1,363 x 1,887 x 832 Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 2 (1,363 x 1,887 x 832) x 2 (1,363 x 1,887 x 832) x 2
Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Cooling [ ℃] Cooling [ ℃]
Temp. Range Temp. Range

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer. * If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m. 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m.
2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.) 3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit *PDM kit: Pressure Drop Modulation kit
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 29 30 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S Standard DVM S Standard

DVMS OUTDOOR UNITS


Model Code AM440HXVAGH1TK AM460HXVAGH1TK AM480HXVAGH1TK Model Code AM560HXVAGH1TK AM580HXVAGH1TK AM600HXVAGH1TK
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 44.00 46.00 48.00 HP 56.00 58.00 60.00
Capacity Cooling [kW] 123.20 128.80 135.20 Capacity Cooling [kW] 156.80 163.20 168.20
Cooling [Btu/hr] 420,400 439,500 461,300 Cooling [Btu/hr] 535,000 556,900 573,900
Power Input Cooling [kW] 34.70 34.15 34.65 Power Input Cooling [kW] 43.10 43.60 45.70
Cooling [kW] 55.60 54.80 55.60 Cooling [kW] 69.10 69.90 73.20
Current Input MCA [A] 89.00 (MCA) 94.50 (MCA) 94.50 (MCA) Current Input MCA [A] 114.00 (MCA) 114.00 (MCA) 121.00 (MCA)
MFA [A] 125.00 125.00 125.00 MFA [A] 150.00 150.00 150.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.55 3.77 3.90 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.64 3.74 3.68
Type SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 4 Type SSC Scroll x 5 SSC Scroll x 5 SSC Scroll x 6
Compressor Output [kW x n] (6.39x2)x2 (6.39)x2 + (6.39x2) (6.39) + (6.39) + (6.39x2) Compressor Output [kW x n] (6.39) + (6.39x2)x2 (6.39) + (6.39x2)x2 (4.96x2) + (6.39x2)x2
Model Name DS-GB066FAVBSG x 4 DS-GB066FAVBSG x 4 DS-GB066FAVBSG x 4 Model Name DS-GB066FAVBSG x 5 DS-GB066FAVBSG x 5 DS-GB052FAVASG x 2 + DS-GB066FAVBSG x 4
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] (620.0 x 2) x 2 (400.0 x 1) x 2 + 620.0 x 2 400.0 x 1 + (620.0 x 2) x 2 Output x n [W] 400.0 x 1 + (620.0 x 2) x 2 (620.0 x 2) x 3 (620.0 x 2) x 3
Fan Air Flow Rate [CMM] 290 x 2 220 x 2 + 290 220 + 255 + 290 Fan Air Flow Rate [CMM] 220 + 290 x 2 255 + 290 x 2 255 + 290 x 2
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00

DVM S INDOOR UNITS


External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 19.05 19.05 19.05 Liquid Pipe [Φ, mm] 19.05 19.05 19.05
Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4" Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4"
Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28 Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28
Connections Gas Pipe [Φ, inch] Connections Gas Pipe [Φ, inch]
1 5/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8" 1 5/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 69.0 69.0 68.0 Sound Pressure [dB(A)] 70.0 70.0 70.0
Sound Sound
Sound Power [dB(A)] 92.0 90.0 90.0 Sound Power [dB(A)] 92.0 92.0 93.0
Net Weight [kg] 298.0 x 2 184.5 x 2 + 298.0 184.5 + 233.0 + 298.0 Net Weight [kg] 184.5 + 298.0 x 2 233.0 + 298.0 x 2 276.0 + 298.0 x 2
External Shipping Weight [kg] 317.0 x 2 200.5 x 2 + 317.0 200.5 + 252.0 + 317.0 External Shipping Weight [kg] 200.5 + 317.0 x 2 252.0 + 317.0 x 2 295.0 + 317.0 x 2
Dimension Net Dimensions (WxHxD) [mm] (880 x 1,695 x 765) x 2 + 1,295 x 1,695 x 765 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 2 Dimension Net Dimensions (WxHxD) [mm]
(1,295 x 1,695 x 765) x 2 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3
Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 2 (948 x 1,887 x 832) x 2 + 1,363 x 1,887 x 832 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 2 Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 2 (1,363 x 1,887 x 832) x 3 (1,363 x 1,887 x 832) x 3
Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Cooling [ ℃] Cooling [ ℃]
Temp. Range Temp. Range

DVM S Standard DVM S Standard

CAC
Model Code AM500HXVAGH1TK AM520HXVAGH1TK AM540HXVAGH1TK Model Code AM620HXVAGH1TK AM640HXVAGH1TK AM660HXVAGH1TK
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 50.00 52.00 54.00 HP 62.00 64.00 66.00
Capacity Cooling [kW] 140.20 145.60 151.20 Capacity Cooling [kW] 173.60 179.20 184.80
Cooling [Btu/hr] 478,400 496,800 515,900 Cooling [Btu/hr] 592,300 611,500 630,600
Power Input Cooling [kW] 36.75 38.63 40.94 Power Input Cooling [kW] 47.58 49.89 52.05
Cooling [kW] 58.90 62.00 65.70 Cooling [kW] 76.30 80.00 83.40
Current Input MCA [A] 101.50 (MCA) 108.60 (MCA) 112.00 (MCA) Current Input MCA [A] 128.10 (MCA) 131.50 (MCA) 133.50 (MCA)
MFA [A] 125.00 125.00 150.00 MFA [A] 200.00 200.00 200.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.81 3.77 3.69 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.65 3.59 3.55
Type SSC Scroll x 5 SSC Scroll x 5 SSC Scroll x 5 Type SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6
Compressor Output [kW x n] (6.39) + (4.96x2) + (6.39x2) (6.39) + (6.39x2) + (6.39x2) (6.39) + (6.39x2) + (6.39x2) Compressor Output [kW x n] (6.39x2) + (6.39x2)x2 (6.39x2) + (6.39x2)x2 (6.39x2)x3
Model Name DS-GB066FAVBSG x 3 + DS- GB052FAVASG x 2 DS-GB066FAVBSG x 5 DS-GB066FAVBSG x 5 Model Name DS-GB066FAVBSG x 6 DS-GB066FAVBSG x 6 DS-GB066FAVBSG x 6
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] 400.0 x 1 + (620.0 x 2) x 2 400.0 x 1 + (620.0 x 2) x 2 400.0 x 1 + (620.0 x 2) x 2 Output x n [W] (620.0 x 2) x 3 (620.0 x 2) x 3 (620.0 x 2) x 3
Fan Air Flow Rate [CMM] 220 + 255 + 290 220 + 290 x 2 220 + 290 x 2 Fan Air Flow Rate [CMM] 290 x 3 290 x 3 290 x 3

FJM
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00
External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 19.05 19.05 19.05 Liquid Pipe [Φ, mm] 22.22 22.22 22.22
Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4" Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8"
Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28 Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98
Connections Gas Pipe [Φ, inch] 1 5/8" 1 5/8" 1 5/8" Connections Gas Pipe [Φ, inch] 2 1/8" 2 1/8" 2 1/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 69.0 69.0 69.0 Sound Pressure [dB(A)] 70.0 70.0 71.0
Sound Sound
Sound Power [dB(A)] 90.0 91.0 92.0 Sound Power [dB(A)] 93.0 93.0 94.0
Net Weight [kg] 184.5 + 276.0 + 298.0 184.5 + 298.0 x 2 184.5 + 298.0 x 2 Net Weight [kg] 298.0 x 3 298.0 x 3 298.0 x 3
External Shipping Weight [kg] 200.5 + 295.0 + 317.0 200.5 + 317.0 x 2 200.5 + 317.0 x 2 External Shipping Weight [kg] 317.0 x 3 317.0 x 3 317.0 x 3
Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 2 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 2 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 2 Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3

CONTROL SYSETM
Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 2 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 2 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 2 Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 3 (1,363 x 1,887 x 832) x 3 (1,363 x 1,887 x 832) x 3
Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Cooling [ ℃] Cooling [ ℃]
Temp. Range Temp. Range

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer. * If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m. 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m.
2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.) 3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit *PDM kit: Pressure Drop Modulation kit
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 31 32 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S Standard DVM S Standard

DVMS OUTDOOR UNITS


Model Code AM680HXVAGH1TK AM700HXVAGH1TK AM720HXVAGH1TK Model Code AM800HXVAGH1TK
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50
HP 68.00 70.00 72.00 HP 80.00
Capacity Cooling [kW] 190.40 196.80 201.80 Capacity Cooling [kW] 224.80
Cooling [Btu/hr] 649,700 671,500 688,600 Cooling [Btu/hr] 767,000
Power Input Cooling [kW] 51.50 52.00 54.10 Power Input Cooling [kW] 60.95
Cooling [kW] 82.60 83.40 86.70 Cooling [kW] 97.70
Current Input MCA [A] 139.00 (MCA) 139.00 (MCA) 146.00 (MCA) Current Input MCA [A] 158.50 (MCA)
MFA [A] 200.00 200.00 200.00 MFA [A] 200.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.70 3.78 3.73 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.69
Type SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 7 Type SSC Scroll x 7
Compressor Output [kW x n] (6.39)x2 + (6.39x2)x2 (6.39) + (6.39) + (6.39x2)x2 (6.39) + (4.96x2) + (6.39x2)x2 Compressor Output [kW x n] (6.39) + (6.39x2)x3
Model Name DS-GB066FAVBSG x 6 DS-GB066FAVBSG x 6 DS-GB066FAVBSG x 5 + DS- GB052FAVASG x 2 Model Name DS-GB066FAVBSG x 7
Type Propeller Propeller Propeller Type Propeller
Output x n [W] (400.0 x 1) x 2 + (620.0 x 2) x 2 400.0 x 1 + (620.0 x 2) x 3 400.0 x 1 + (620.0 x 2) x 3 Output x n [W] (620.0 x 2) x 4
Fan Air Flow Rate [CMM] 220 x 2 + 290 x 2 220 + 255 + 290 x 2 220 + 255 + 290 x 2 Fan Air Flow Rate [CMM] 255 + 290 x 3
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00

DVM S INDOOR UNITS


External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45
Liquid Pipe [Φ, mm] 22.22 22.22 22.22 Liquid Pipe [Φ, mm] 22.22
Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8" Liquid Pipe [Φ, inch] 7/8"
Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98 Piping Gas Pipe [Φ, mm] 53.98
Connections Gas Pipe [Φ, inch] Connections Gas Pipe [Φ, inch]
2 1/8" 2 1/8" 2 1/8" 2 1/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0
Sound Pressure [dB(A)] 70.0 70.0 71.0 Sound Pressure [dB(A)] 71.0
Sound Sound
Sound Power [dB(A)] 93.0 93.0 93.0 Sound Power [dB(A)] 94.0
Net Weight [kg] 184.5 x 2 + 298.0 x 2 184.5 + 233.0 + 298.0 x 2 184.5 + 276.0 + 298.0 x 2 Net Weight [kg] 233.0 + 298.0 x 3
External Shipping Weight [kg] 200.5 x 2 + 317.0 x 2 200.5 + 252.0 + 317.0 x 2 200.5 + 295.0 + 317.0 x 2 External Shipping Weight [kg] 252.0 + 317.0 x 3
Dimension Net Dimensions (WxHxD) [mm] (880 x 1,695 x 765) x 2 + (1,295 x 1,695 x 765) x 2 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 3 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 3 Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,695 x 765) x 4
Shipping Dimensions (WxHxD) [mm] (948 x 1,887 x 832) x 2 + (1,363 x 1,887 x 832) x 2 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 3 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 3 Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 4
Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Operating -5.0 ~ 48.0
Cooling [ ℃] Cooling [ ℃]
Temp. Range Temp. Range

DVM S Compact
DVM S Standard

CAC
Model Code AM740HXVAGH1TK AM760HXVAGH1TK AM780HXVAGH1TK Model Code AM360HXVAGH2TK AM380HXVAGH2TK
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50
HP 74.00 76.00 78.00 HP 36.00 38.00
Capacity Cooling [kW] 207.20 212.80 218.40 Capacity Cooling [kW] 100.80 106.40
Cooling [Btu/hr] 707,000 726,100 745,200 Cooling [Btu/hr] 343,900 363,100
Power Input Cooling [kW] 55.98 58.29 60.45 Power Input Cooling [kW] 25.50 27.70
Cooling [kW] 89.80 93.50 96.90 Cooling [kW] 40.33 43.78
Current Input MCA [A] 153.10 (MCA) 156.50 (MCA) 158.50 (MCA) Current Input MCA [A] 80.00 (MCA) 83.00 (MCA)
MFA [A] 200.00 200.00 200.00 MFA [A] 90.00 100.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.70 3.65 3.61 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.95 3.84
Type SSC Scroll x 7 SSC Scroll x 7 SSC Scroll x 7 Type SSC Scroll x 3 SSC Scroll x 3
Compressor Output [kW x n] (6.39) + (6.39x2) + (6.39x2)x2 (6.39) + (6.39x2) + (6.39x2)x2 (6.39) + (6.39x2)x3 Compressor Output [kW x n] (6.39) + (6.39x2) (6.39) + (6.76x2)
Model Name DS-GB066FAVBSG x 7 DS-GB066FAVBSG x 7 DS-GB066FAVBSG x 7 Model Name DS-GB066FAVBSG x 3 DS-GB066FAVBSG x 1 + DS-GB070FAVASG x
Type Type 2
Propeller Propeller Propeller Propeller Propeller
Output x n [W] 400.0 x 1 + (620.0 x 2) x 3 400.0 x 1 + (620.0 x 2) x 3 400.0 x 1 + (620.0 x 2) x 3 Output x n [W] 400.0 x 1 + 620.0 x 2 400.0 x 1 + 620.0 x 2
Fan Air Flow Rate [CMM] 220 + 290 x 3 220 + 290 x 3 220 + 290 x 3 Fan Air Flow Rate [CMM] 220 + 310 220 + 310

FJM
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00
External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45
Liquid Pipe [Φ, mm] 22.22 22.22 22.22 Liquid Pipe [Φ, mm] 19.05 19.05
Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8" Liquid Pipe [Φ, inch] 3/4" 3/4"
Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98 Piping Gas Pipe [Φ, mm] 41.28 41.28
Connections Gas Pipe [Φ, inch] 2 1/8" 2 1/8" 2 1/8" Connections Gas Pipe [Φ, inch] 1 5/8" 1 5/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0
Sound Pressure [dB(A)] 71.0 71.0 71.0 Sound Pressure [dB(A)] 68.0 68.0
Sound Sound
Sound Power [dB(A)] 93.0 93.0 94.0 Sound Power [dB(A)] 91.0 91.0
Net Weight [kg] 184.5 + 298.0 x 3 184.5 + 298.0 x 3 184.5 + 298.0 x 3 Net Weight [kg] 184.5 + 356.0 184.5 + 356.0
External Shipping Weight [kg] 200.5 + 317.0 x 3 200.5 + 317.0 x 3 200.5 + 317.0 x 3 External Shipping Weight [kg] 200.5 + 371.0 200.5 + 371.0
Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 3 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 3 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 3 Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 + 1,295 x 1,695 x 765 880 x 1,695 x 765 + 1,295 x 1,695 x 765

CONTROL SYSETM
Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 3 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 3 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 3 Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 + 1,363 x 1,887 x 832 948 x 1,887 x 832 + 1,363 x 1,887 x 832
Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Operating -5.0 ~ 48.0 -5.0 ~ 48.0
Cooling [ ℃] Cooling [ ℃]
Temp. Range Temp. Range

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer. * If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m. 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m.
2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.) 3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit *PDM kit: Pressure Drop Modulation kit
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 33 34 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S Compact DVM S Compact

DVMS OUTDOOR UNITS


Model Code AM460HXVAGH2TK AM480HXVAGH2TK AM500HXVAGH2TK Model Code AM620HXVAGH2TK AM640HXVAGH2TK AM680HXVAGH2TK
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 46.00 48.00 50.00 HP 62.00 64.00 68.00
Capacity Cooling [kW] 128.80 134.40 140.00 Capacity Cooling [kW] 173.60 179.20 190.40
Cooling [Btu/hr] 439,500 458,600 477,700 Cooling [Btu/hr] 592,300 611,500 649,700
Power Input Cooling [kW] 34.49 36.65 36.40 Power Input Cooling [kW] 44.80 47.00 51.80
Cooling [kW] 54.68 58.08 57.11 Cooling [kW] 70.61 74.06 82.43
Current Input MCA [A] 100.50 (MCA) 102.50 (MCA) 113.00 (MCA) Current Input MCA [A] 138.00 (MCA) 141.00 (MCA) 144.00 (MCA)
MFA [A] 125.00 125.00 125.00 MFA [A] 175.00 175.00 175.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.73 3.67 3.85 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.88 3.81 3.68
Type SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 4 Type SSC Scroll x 5 SSC Scroll x 5 SSC Scroll x 6
Compressor Output [kW x n] (6.39x2) + (6.76x2) (6.39x2) + (6.76x2) (6.39x2) + (6.76x2) Compressor Output [kW x n] (6.39) + (6.39x2) + (6.76x2) (6.39) + (6.76x2)x2 (6.39x2)x2 + (6.39x2)
Model Name DS-GB066FAVBSG x 2 + DS- GB070FAVASG x 2 DS-GB066FAVBSG x 2 + DS- GB070FAVASG x 2 DS-GB066FAVBSG x 2 + DS-GB070FAVASG x 2 Model Name DS-GB066FAVBSG x 3 + DS-GB070FAVASG x 2 DS-GB066FAVBSG x 1 + DS-GB070FAVASG x 4 DS-GB066FAVBSG x 6
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] (620.0 x 2) x 2 (620.0 x 2) x 2 (620.0 x 2) x 2 Output x n [W] 400.0 x 1 + (620.0 x 2) x 2 400.0 x 1 + (620.0 x 2) x 2 (620.0 x 2) x 3
Fan Air Flow Rate [CMM] 290 + 310 290 + 310 310 x 2 Fan Air Flow Rate [CMM] 220 + 310 x 2 220 + 310 x 2 290 x 2 + 310
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00

DVM S INDOOR UNITS


External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 19.05 19.05 19.05 Liquid Pipe [Φ, mm] 22.22 22.22 22.22
Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4" Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8"
Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28 Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98
Connections Gas Pipe [Φ, inch] 1 5/8" 1 5/8" 1 5/8" Connections Gas Pipe [Φ, inch] 2 1/8" 2 1/8" 2 1/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 69.0 70.0 70.0 Sound Pressure [dB(A)] 71.0 71.0 71.0
Sound Sound
Sound Power [dB(A)] 92.0 93.0 93.0 Sound Power [dB(A)] 94.0 94.0 95.0
Net Weight [kg] 298.0 + 356.0 298.0 + 356.0 356.0 x 2 Net Weight [kg] 184.5 + 356.0 x 2 184.5 + 356.0 x 2 298.0 x 2 + 356.0
External Shipping Weight [kg] 317.0 + 371.0 317.0 + 371.0 371.0 x 2 External Shipping Weight [kg] 200.5 + 371.0 x 2 200.5 + 371.0 x 2 317.0 x 2 + 371.0
Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2 Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 2 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 3
Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 2 (1,363 x 1,887 x 832) x 2 (1,363 x 1,887 x 832) x 2 Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 2 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 2 (1,363 x 1,887 x 832) x 3
Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Cooling [ ℃] Cooling [ ℃]
Temp. Range Temp. Range

DVM S Compact DVM S Compact

CAC
Model Code AM520HXVAGH2TK AM580HXVAGH2TK AM600HXVAGH2TK Model Code AM700HXVAGH2TK AM720HXVAGH2TK AM740HXVAGH2TK
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 52.00 58.00 60.00 HP 70.00 72.00 74.00
Capacity Cooling [kW] 145.60 162.40 168.00 Capacity Cooling [kW] 196.00 201.60 207.20
Cooling [Btu/hr] 496,800 554,100 573,200 Cooling [Btu/hr] 668,800 687,900 707,000
Power Input Cooling [kW] 38.60 42.89 45.05 Power Input Cooling [kW] 54.00 53.75 55.95
Cooling [kW] 60.56 68.18 71.58 Cooling [kW] 85.88 84.91 88.36
Current Input MCA [A] 116.00 (MCA) 125.50 (MCA) 127.50 (MCA) Current Input MCA [A] 147.00 (MCA) 157.50 (MCA) 160.50 (MCA)
MFA [A] 150.00 150.00 150.00 MFA [A] 175.00 175.00 200.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.77 3.79 3.73 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.63 3.75 3.70
Type SSC Scroll x 4 SSC Scroll x 5 SSC Scroll x 5 Type SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6
Compressor Output [kW x n] (6.76x2)x2 (6.39) + (6.39x2) + (6.76x2) (6.39) + (6.39x2) + (6.76x2) Compressor Output [kW x n] (6.39x2)x2 + (6.76x2) (6.39x2) + (6.39x2) + (6.76x2) (6.39x2) + (6.76x2)x2
Model Name DS-GB070FAVASG x 4 DS-GB066FAVBSG x 3 + DS-GB070FAVASG x 2 DS-GB066FAVBSG x 3 + DS-GB070FAVASG x 2 Model Name DS-GB066FAVBSG x 4 + DS-GB070FAVASG x 2 DS-GB066FAVBSG x 4 + DS- GB070FAVASG x 2 DS-GB066FAVBSG x 2 + DS-GB070FAVASG x 4
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] (620.0 x 2) x 2 400.0 x 1 + (620.0 x 2) x 2 400.0 x 1 + (620.0 x 2) x 2 Output x n [W] (620.0 x 2) x 3 (620.0 x 2) x 3 (620.0 x 2) x 3
Fan Air Flow Rate [CMM] 310 x 2 220 + 290 + 310 220 + 290 + 310 Fan Air Flow Rate [CMM] 290 x 2 + 310 290 + 310 x 2 290 + 310 x 2

FJM
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00
External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 19.05 19.05 19.05 Liquid Pipe [Φ, mm] 22.22 22.22 22.22
Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4" Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8"
Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28 Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98
Connections Gas Pipe [Φ, inch] Connections Gas Pipe [Φ, inch]
1 5/8" 1 5/8" 1 5/8" 2 1/8" 2 1/8" 2 1/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 70.0 70.0 70.0 Sound Pressure [dB(A)] 71.0 71.0 71.0
Sound Sound
Sound Power [dB(A)] 93.0 93.0 93.0 Sound Power [dB(A)] 95.0 95.0 95.0
Net Weight [kg] 356.0 x 2 184.5 + 298.0 + 356.0 184.5 + 298.0 + 356.0 Net Weight [kg] 298.0 x 2 + 356.0 298.0 + 356.0 x 2 298.0 + 356.0 x 2
External Shipping Weight [kg] 371.0 x 2 200.5 + 317.0 + 371.0 200.5 + 317.0 + 371.0 External Shipping Weight [kg] 317.0 x 2 + 371.0 317.0 + 371.0 x 2 317.0 + 371.0 x 2
Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 2 880 x 1,695 x 765 + (1,295 x 1,695 x 765) x 2 Dimension Net Dimensions (WxHxD) [mm]
(1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3

CONTROL SYSETM
Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 2 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 2 948 x 1,887 x 832 + (1,363 x 1,887 x 832) x 2 Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 3 (1,363 x 1,887 x 832) x 3 (1,363 x 1,887 x 832) x 3
Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Operating -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Cooling [ ℃] Cooling [ ℃]
Temp. Range Temp. Range

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer. * If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m. 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m.
2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.) 3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit *PDM kit: Pressure Drop Modulation kit
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 35 36 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S Compact DVM S Cooling Only

DVMS OUTDOOR UNITS


Model Code AM760HXVAGH2TK AM780HXVAGH2TK Model Code AM140MXVAGC/TS AM160MXVAGC/TS AM180MXVAGC/TS
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 76.00 78.00 HP 14.00 16.00 18.00
Capacity Cooling [kW] 212.80 218.40 Capacity Cooling [kW] 40.00 45.00 50.40
Cooling [Btu/hr] 726,100 745,200 Cooling [Btu/hr] 136,500 153,500 172,000
Power Input Cooling [kW] 55.70 57.90 Power Input Cooling [kW] 10.08 12.10 14.20
Cooling [kW] 87.39 90.84 Cooling [kW] 16.20 19.40 22.80
Current Input MCA [A] 171.00 (MCA) 174.00 (MCA) Current Input MCA [A] 25.00 (MCA) 32.00 (MCA) 39.10 (MCA)
MFA [A] 200.00 200.00 MFA [A] 32.00 40.00 50.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.82 3.77 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.97 3.72 3.55
Type SSC Scroll x 6 SSC Scroll x 6 Type SSC Scroll x 1 SSC Scroll x 1 SSC Scroll x 1
Compressor Output [kW x n] (6.39x2) + (6.76x2)x2 (6.76x2)x3 Compressor Output [kW x n] (6.39) (7.81) (7.81)
Model Name DS-GB066FAVBSG x 2 + DS-GB070FAVASG x 4 DS-GB070FAVASG x 6 Model Name DS-GB066FAVB x 1 DS4GJ5080FVA x 1 DS4GJ5080FVA x 1
Type Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] (620.0 x 2) x 3 (620.0 x 2) x 3 Output x n [W] 620.0 x 2 620.0 x 2 620.0 x 2
Fan Air Flow Rate [CMM] 310 x 3 310 x 3 Fan Air Flow Rate [CMM] 255 255 290
External Static Pressure [mmAq] 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00

DVM S INDOOR UNITS


External Static Pressure [Pa] 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 22.22 22.22 Liquid Pipe [Φ, mm] 12.70 12.70 15.88
Liquid Pipe [Φ, inch] 7/8" 7/8" Liquid Pipe [Φ, inch] 1/2" 1/2" 5/8"
Piping Gas Pipe [Φ, mm] 53.98 53.98 Piping Gas Pipe [Φ, mm] 28.58 28.58 28.58
Connections Gas Pipe [Φ, inch] 2 1/8" 2 1/8" Connections Gas Pipe [Φ, inch] 1 1/8" 1 1/8" 1 1/8"
Installation Limitation [Max Length] [m] 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 72.0 72.0 Sound Pressure [dB(A)] 61.0 63.0 64.0
Sound Sound
Sound Power [dB(A)] 96.0 96.0 Sound Power [dB(A)] 81.0 83.0 84.0
Net Weight [kg] 356.0 x 3 356.0 x 3 Net Weight [kg] 225.0 252.0 252.0
External Shipping Weight [kg] 371.0 x 3 371.0 x 3 External Shipping Weight [kg] 244.0 271.0 271.0
Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,695 x 765) x 3 (1,295 x 1,695 x 765) x 3 Dimension Net Dimensions (WxHxD) [mm] 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,695 x 765
Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 3 (1,363 x 1,887 x 832) x 3 Shipping Dimensions (WxHxD) [mm] 1,363 x 1,887 x 832 1,363 x 1,887 x 832 1,363 x 1,887 x 832
Operating -5.0 ~ 48.0 -5.0 ~ 48.0 Operating
Cooling [ ℃] Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Temp. Range Temp. Range

DVM S Cooling Only DVM S Cooling Only

CAC
Model Code AM080MXVAGC/TS AM100MXVAGC/TS AM120MXVAGC/TS Model Code AM200MXVAGC/TS AM220MXVAGC/TS AM240MXVAGC/TS
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 8.00 10.00 12.00 HP 20.00 22.00 24.00
Capacity Cooling [kW] 22.40 28.00 33.60 Capacity Cooling [kW] 56.00 61.60 67.20
Cooling [Btu/hr] 76,400 95,500 114,600 Cooling [Btu/hr] 191,100 210,200 229,300
Power Input Cooling [kW] 4.98 6.36 8.62 Power Input Cooling [kW] 16.62 19.68 17.87
Cooling [kW] 8.00 10.20 13.80 Cooling [kW] 26.60 31.60 28.70
Current Input MCA [A] 18.00 (MCA) 22.80 (MCA) 25.00 (MCA) Current Input MCA [A] 42.00 (MCA) 44.50 (MCA) 44.50 (MCA)
MFA [A] 25.00 32.00 32.00 MFA [A] 63.00 63.00 63.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 4.50 4.40 3.90 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.37 3.13 3.76
Type SSC Scroll x 1 SSC Scroll x 1 SSC Scroll x 1 Type SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 2
Compressor Output [kW x n] (5.18) (5.18) (6.39) Compressor Output [kW x n] (5.18x2) (5.18x2) (6.39x2)
Model Name DS-GB052FAVB x 1 DS-GB052FAVB x 1 DS-GB066FAVB x 1 Model Name DS-GB052FAVB x 2 DS-GB052FAVB x 2 DS-GB066FAVB x 2
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] 830.0 x 1 830.0 x 1 830.0 x 1 Output x n [W] 620.0 x 2 620.0 x 2 620.0 x 2
Fan Air Flow Rate [CMM] 170 170 220 Fan Air Flow Rate [CMM] 290 290 320

FJM
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00
External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 9.52 9.52 12.70 Liquid Pipe [Φ, mm] 15.88 15.88 15.88
Liquid Pipe [Φ, inch] 3/8" 3/8" 1/2" Liquid Pipe [Φ, inch] 5/8" 5/8" 5/8"
Piping Gas Pipe [Φ, mm] 19.05 22.22 28.58 Piping Gas Pipe [Φ, mm] 28.58 28.58 34.92
Connections Gas Pipe [Φ, inch] 3/4" 7/8" 1 1/8" Connections Gas Pipe [Φ, inch] 1 1/8" 1 1/8" 1 3/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 57.0 61.0 62.0 Sound Pressure [dB(A)] 65.0 65.0 67.0
Sound Sound
Sound Power [dB(A)] 77.0 80.0 81.0 Sound Power [dB(A)] 87.0 89.0 89.0
Net Weight [kg] 185.0 185.0 190.0 Net Weight [kg] 280.0 280.0 322.0
External Shipping Weight [kg] 197.0 197.0 202.0 External Shipping Weight [kg] 299.0 299.0 344.0
Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 880 x 1,695 x 765 880 x 1,695 x 765 Dimension Net Dimensions (WxHxD) [mm] 1,295 x 1,695 x 765 1,295 x 1,695 x 765 1,295 x 1,795 x 765

CONTROL SYSETM
Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 948 x 1,887 x 832 948 x 1,887 x 832 Shipping Dimensions (WxHxD) [mm] 1,363 x 1,887 x 832 1,363 x 1,887 x 832 1,363 x 1,987 x 832
Operating Operating
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Temp. Range Temp. Range

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer. * If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m. 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m.
2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.) 3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit *PDM kit: Pressure Drop Modulation kit
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 37 38 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S Cooling Only DVM S Cooling Only

DVMS OUTDOOR UNITS


Model Code AM260MXVAGC/TS AM280MXVAGC/TS AM300MXVAGC/TS Model Code AM380MXVAGC/TS AM400MXVAGC/TS AM420MXVAGC/TS
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 26.00 28.00 30.00 HP 38.00 40.00 42.00
Capacity Cooling [kW] 72.80 78.60 84.00 Capacity Cooling [kW] 106.60 112.00 117.60
Cooling [Btu/hr] 248,400 268,200 286,600 Cooling [Btu/hr] 363,700 382,200 401,300
Power Input Cooling [kW] 21.41 23.39 26.33 Power Input Cooling [kW] 31.78 33.88 36.30
Cooling [kW] 34.30 37.50 42.20 Cooling [kW] 51.00 54.40 58.20
Current Input MCA [A] 60.00 (MCA) 65.00 (MCA) 65.00 (MCA) Current Input MCA [A] 76.50 (MCA) 83.60 (MCA) 86.50 (MCA)
MFA [A] 75.00 75.00 75.00 MFA [A] 90.00 100.00 100.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.40 3.36 3.19 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.35 3.31 3.24
Type SSC Scroll x 2 SSC Scroll x 2 SSC Scroll x 2 Type SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 4
Compressor Output [kW x n] (6.39x2) (6.76x2) (7.81x2) Compressor Output [kW x n] (7.81) + (5.18x2) (7.81) + (5.18x2) (5.18x2) + (5.18x2)
Model Name DS-GB066FAVB x 2 DS-GB070FAVA x 2 DS4GJ5080FVA x 2 Model Name DS4GJ5080FVA x 1 + DS- GB052FAVB x 2 DS4GJ5080FVA x 1 + DS- GB052FAVB x 2 DS-GB052FAVB x 4
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] 620.0 x 2 620.0 x 2 620.0 x 2 Output x n [W] (620.0 x 2) x 2 (620.0 x 2) x 2 (620.0 x 2) x 2
Fan Air Flow Rate [CMM] 320 340 340 Fan Air Flow Rate [CMM] 255 + 290 290 x 2 290 x 2
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00

DVM S INDOOR UNITS


External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 19.05 19.05 19.05 Liquid Pipe [Φ, mm] 19.05 19.05 19.05
Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4" Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4"
Piping Gas Pipe [Φ, mm] 34.92 34.92 34.92 Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28
Connections Gas Pipe [Φ, inch] 1 3/8" 1 3/8" 1 3/8" Connections Gas Pipe [Φ, inch] 1 5/8" 1 5/8" 1 5/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 67.0 69.0 69.0 Sound Pressure [dB(A)] 67.0 68.0 68.0
Sound Sound
Sound Power [dB(A)] 89.0 90.0 90.0 Sound Power [dB(A)] 90.0 90.0 91.0
Net Weight [kg] 330.0 335.0 342.0 Net Weight [kg] 252.0 + 280.0 252.0 + 280.0 280.0 x 2
External Shipping Weight [kg] 352.0 357.0 364.0 External Shipping Weight [kg] 271.0 + 299.0 271.0 + 299.0 299.0 x 2
Dimension Net Dimensions (WxHxD) [mm] 1,295 x 1,795 x 765 1,295 x 1,795 x 765 1,295 x 1,795 x 765 Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2 (1,295 x 1,695 x 765) x 2
Shipping Dimensions (WxHxD) [mm] 1,363 x 1,987 x 832 1,363 x 1,987 x 832 1,363 x 1,987 x 832 Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 2 (1,363 x 1,887 x 832) x 2 (1,363 x 1,887 x 832) x 2
Operating Operating
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Temp. Range Temp. Range

DVM S Cooling Only DVM S Cooling Only

CAC
Model Code AM320MXVAGC/TS AM340MXVAGC/TS AM360MXVAGC/TS Model Code AM440MXVAGC/TS AM460MXVAGC/TS AM480MXVAGC/TS
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 32.00 34.00 36.00 HP 44.00 46.00 48.00
Capacity Cooling [kW] 89.60 95.20 101.60 Capacity Cooling [kW] 123.20 129.00 134.40
Cooling [Btu/hr] 305,700 324,800 346,700 Cooling [Btu/hr] 420,400 440,200 458,600
Power Input Cooling [kW] 26.04 28.30 29.76 Power Input Cooling [kW] 39.36 38.43 40.53
Cooling [kW] 41.80 45.40 47.80 Cooling [kW] 63.20 61.60 65.00
Current Input MCA [A] 67.30 (MCA) 69.50 (MCA) 69.50 (MCA) Current Input MCA [A] 89.00 (MCA) 97.00 (MCA) 104.10 (MCA)
MFA [A] 75.00 80.00 80.00 MFA [A] 100.00 125.00 125.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.44 3.36 3.41 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.13 3.36 3.32
Type SSC Scroll x 3 SSC Scroll x 3 SSC Scroll x 3 Type SSC Scroll x 4 SSC Scroll x 3 SSC Scroll x 3
Compressor Output [kW x n] (5.18) + (5.18x2) (6.39) + (5.18x2) (6.39) + (5.18x2) Compressor Output [kW x n] (5.18x2)x2 (7.81) + (7.81x2) (7.81) + (7.81x2)
Model Name DS-GB052FAVB x 3 DS-GB066FAVB x 1 + DS-GB052FAVB x 2 DS-GB066FAVB x 1 + DS-GB052FAVB x 2 Model Name DS-GB052FAVB x 4 DS4GJ5080FVA x 3 DS4GJ5080FVA x 3
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] 830.0 x 1 + 620.0 x 2 830.0 x 1 + 620.0 x 2 (620.0 x 2) x 2 Output x n [W] (620.0 x 2) x 2 (620.0 x 2) x 2 (620.0 x 2) x 2
Fan Air Flow Rate [CMM] 170 + 290 220 + 290 255 + 290 Fan Air Flow Rate [CMM] 290 x 2 255 + 340 290 + 340

FJM
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00
External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 19.05 19.05 19.05 Liquid Pipe [Φ, mm] 19.05 19.05 19.05
Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4" Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4"
Piping Gas Pipe [Φ, mm] 34.92 34.92 41.28 Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28
Connections Gas Pipe [Φ, inch] 1 3/8" 1 3/8" 1 5/8" Connections Gas Pipe [Φ, inch] 1 5/8" 1 5/8" 1 5/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 66.0 67.0 66.0 Sound Pressure [dB(A)] 68.0 70.0 70.0
Sound Sound
Sound Power [dB(A)] 89.0 90.0 90.0 Sound Power [dB(A)] 92.0 91.0 91.0
Net Weight [kg] 185.0 + 280.0 190.0 + 280.0 225.0 + 280.0 Net Weight [kg] 280.0 x 2 252.0 + 342.0 252.0 + 342.0
External Shipping Weight [kg] 197.0 + 299.0 202.0 + 299.0 244.0 + 299.0 External Shipping Weight [kg] 299.0 x 2 271.0 + 364.0 271.0 + 364.0
Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 + 1,295 x 1,695 x 765 880 x 1,695 x 765 + 1,295 x 1,695 x 765 (1,295 x 1,695 x 765) x 2 Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,695 x 765) x 2 1,295 x 1,695 x 765 + 1,295 x 1,795 x 765 1,295 x 1,695 x 765 + 1,295 x 1,795 x 765

CONTROL SYSETM
Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 + 1,363 x 1,887 x 832 948 x 1,887 x 832 + 1,363 x 1,887 x 832 (1,363 x 1,887 x 832) x 2 Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 2 1,363 x 1,887 x 832 + 1,363 x 1,987 x 832 1,363 x 1,887 x 832 + 1,363 x 1,987 x 832
Operating Operating
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Temp. Range Temp. Range

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer. * If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m. 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m.
2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.) 3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit *PDM kit: Pressure Drop Modulation kit
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 39 40 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S Cooling Only DVM S Cooling Only

DVMS OUTDOOR UNITS


Model Code AM500MXVAGC/TS AM520MXVAGC/TS AM540MXVAGC/TS Model Code AM620MXVAGC/TS AM640MXVAGC/TS AM660MXVAGC/TS
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 50.00 52.00 54.00 HP 62.00 64.00 66.00
Capacity Cooling [kW] 140.00 145.60 151.20 Capacity Cooling [kW] 173.60 179.20 185.60
Cooling [Btu/hr] 477,700 496,800 515,900 Cooling [Btu/hr] 592,300 611,500 633,300
Power Input Cooling [kW] 42.95 46.01 44.20 Power Input Cooling [kW] 52.37 54.63 56.09
Cooling [kW] 68.80 73.80 70.90 Cooling [kW] 84.00 87.60 90.00
Current Input MCA [A] 107.00 (MCA) 109.50 (MCA) 109.50 (MCA) Current Input MCA [A] 132.30 (MCA) 134.50 (MCA) 134.50 (MCA)
MFA [A] 125.00 125.00 125.00 MFA [A] 150.00 150.00 150.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.26 3.16 3.42 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.31 3.28 3.31
Type SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 4 Type SSC Scroll x 5 SSC Scroll x 5 SSC Scroll x 5
Compressor Output [kW x n] (5.18x2) + (7.81x2) (5.18x2) + (7.81x2) (6.39x2) + (7.81x2) Compressor Output [kW x n] (5.18) + (5.18x2) + (7.81x2) (6.39) + (5.18x2) + (7.81x2) (6.39) + (5.18x2) + (7.81x2)
Model Name DS-GB052FAVB x 2 + DS4GJ5080FVA x 2 DS-GB052FAVB x 2 + DS4GJ5080FVA x 2 DS-GB066FAVB x 2 + DS4GJ5080FVA x 2 Model Name DS-GB052FAVB x 3 +DS4GJ5080FVA x 2 DS-GB066FAVB x 1 + DS- GB052FAVB x 2 + DS-GB066FAVB x 1 + DS-GB052FAVB x 2 +
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] (620.0 x 2) x 2 (620.0 x 2) x 2 (620.0 x 2) x 2 Output x n [W] 830.0 x 1 + (620.0 x 2) x 2 830.0 x 1 + (620.0 x 2) x 2 (620.0 x 2) x 3
Fan Air Flow Rate [CMM] 290 + 340 290 + 340 320 + 340 Fan Air Flow Rate [CMM] 170 + 290 + 340 220 + 290 + 340 255 + 290 + 340
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00

DVM S INDOOR UNITS


External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 19.05 19.05 19.05 Liquid Pipe [Φ, mm] 22.22 22.22 22.22
Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4" Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8"
Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28 Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98
Connections Gas Pipe [Φ, inch] Connections Gas Pipe [Φ, inch] 2 1/8" 2 1/8" 2 1/8"
1 5/8" 1 5/8" 1 5/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 70.0 70.0 71.0 Sound Pressure [dB(A)] 71.0 71.0 71.0
Sound Sound
Sound Power [dB(A)] 92.0 93.0 93.0 Sound Power [dB(A)] 93.0 93.0 93.0
Net Weight [kg] 280.0 + 342.0 280.0 + 342.0 322.0 + 342.0 Net Weight [kg] 185.0 + 280.0 + 342.0 190.0 + 280.0 + 342.0 225.0 + 280.0 + 342.0
External Shipping Weight [kg] 299.0 + 364.0 299.0 + 364.0 344.0 + 364.0 External Shipping Weight [kg] 197.0 + 299.0 + 364.0 202.0 + 299.0 + 364.0 244.0 + 299.0 + 364.0
Dimension Net Dimensions (WxHxD) [mm] 1,295 x 1,695 x 765 + 1,295 x 1,795 x 765 1,295 x 1,695 x 765 + 1,295 x 1,795 x 765 Dimension Net Dimensions (WxHxD) [mm] 880 x 1,695 x 765 + 1,295 x 1,695 x 765 + 1,295 x 1,795 x 880 x 1,695 x 765 + 1,295 x1,695 x 765 + 1,295 x 1,795 x (1,295 x 1,695 x 765) x 2 + 1,295 x 1,795 x 765
(1,295 x 1,795 x 765) x 2
Shipping Dimensions (WxHxD) [mm] 1,363 x 1,887 x 832 + 1,363 x 1,987 x 832 1,363 x 1,887 x 832 + 1,363 x 1,987 x 832 (1,363 x 1,987 x 832) x 2 Shipping Dimensions (WxHxD) [mm] 948 x 1,887 x 832 + 1,363 x 1,887 x 832 + 1,363 x 1,987 x 948 x 1,887 x 832 + 1,363 x 1,887 x 832 + 1,363 x 1,987 x (1,363 x 1,887 x 832) x 2 + 1,363 x 1,987 x 832
Operating Operating
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Temp. Range Temp. Range

DVM S Cooling Only DVM S Cooling Only

CAC
Model Code AM560MXVAGC/TS AM580MXVAGC/TS AM600MXVAGC/TS Model Code AM680MXVAGC/TS AM700MXVAGC/TS AM720MXVAGC/TS
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 56.00 58.00 60.00 HP 68.00 70.00 72.00
Capacity Cooling [kW] 156.80 162.60 168.00 Capacity Cooling [kW] 190.60 196.00 201.60
Cooling [Btu/hr] 535,000 554,800 573,200 Cooling [Btu/hr] 650,400 668,800 687,900
Power Input Cooling [kW] 47.74 49.72 52.66 Power Input Cooling [kW] 58.11 60.21 62.63
Cooling [kW] 76.50 79.70 84.40 Cooling [kW] 93.20 96.60 100.40
Current Input MCA [A] 125.00 (MCA) 130.00 (MCA) 130.00 (MCA) Current Input MCA [A] 141.50 (MCA) 148.60 (MCA) 151.50 (MCA)
MFA [A] 150.00 150.00 150.00 MFA [A] 175.00 175.00 175.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.28 3.27 3.19 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.28 3.26 3.22
Type SSC Scroll x 4 SSC Scroll x 4 SSC Scroll x 4 Type SSC Scroll x 5 SSC Scroll x 5 SSC Scroll x 6
Compressor Output [kW x n] (6.39x2) + (7.81x2) (6.76x2) + (7.81x2) (7.81x2)x2 Compressor Output [kW x n] (7.81) + (5.18x2) + (7.81x2) (7.81) + (5.18x2) + (7.81x2) (5.18x2) + (5.18x2) + (7.81x2)
Model Name DS-GB066FAVB x 2 + DS4GJ5080FVA x 2 DS-GB070FAVA x 2 + DS4GJ5080FVA x 2 DS4GJ5080FVA x 4 Model Name DS4GJ5080FVA x 3 + DS- GB052FAVB x 2 DS4GJ5080FVA x 3 + DS-GB052FAVB x 2 DS-GB052FAVB x 4 + DS4GJ5080FVA x 2
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] (620.0 x 2) x 2 (620.0 x 2) x 2 (620.0 x 2) x 2 Output x n [W] (620.0 x 2) x 3 (620.0 x 2) x 3 (620.0 x 2) x 3
Fan Air Flow Rate [CMM] 320 + 340 340 x 2 340 x 2 Fan Air Flow Rate [CMM] 255 + 290 + 340 290 x 2 + 340 290 x 2 + 340

FJM
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00
External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 19.05 19.05 19.05 Liquid Pipe [Φ, mm] 22.22 22.22 22.22
Liquid Pipe [Φ, inch] 3/4" 3/4" 3/4" Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8"
Piping Gas Pipe [Φ, mm] 41.28 41.28 41.28 Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98
Connections Gas Pipe [Φ, inch] 1 5/8" 1 5/8" 1 5/8" Connections Gas Pipe [Φ, inch] 2 1/8" 2 1/8" 2 1/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 71.0 72.0 72.0 Sound Pressure [dB(A)] 71.0 71.0 72.0
Sound Sound
Sound Power [dB(A)] 93.0 93.0 93.0 Sound Power [dB(A)] 93.0 93.0 94.0
Net Weight [kg] 330.0 + 342.0 335.0 + 342.0 342.0 x 2 Net Weight [kg] 252.0 + 280.0 + 342.0 252.0 + 280.0 + 342.0 280.0 x 2 + 342.0
External Shipping Weight [kg] 352.0 + 364.0 357.0 + 364.0 364.0 x 2 External Shipping Weight [kg] 271.0 + 299.0 + 364.0 271.0 + 299.0 + 364.0 299.0 x 2 + 364.0
Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,795 x 765) x 2 (1,295 x 1,795 x 765) x 2 (1,295 x 1,795 x 765) x 2 Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,695 x 765) x 2 + 1,295 x 1,795 x 765 (1,295 x 1,695 x 765) x 2 + 1,295 x 1,795 x 765 (1,295 x 1,695 x 765) x 2 + 1,295 x 1,795 x 765

CONTROL SYSETM
Shipping Dimensions (WxHxD) [mm] (1,363 x 1,987 x 832) x 2 (1,363 x 1,987 x 832) x 2 (1,363 x 1,987 x 832) x 2 Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 2 +1,363 x 1,987 x 832 (1,363 x 1,887 x 832) x 2 + 1,363 x 1,987 x 832 (1,363 x 1,887 x 832) x 2 + 1,363 x 1,987 x 832
Operating Operating
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Temp. Range Temp. Range

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer. * If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m. 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m.
2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.) 3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit *PDM kit: Pressure Drop Modulation kit
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 41 42 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S Cooling Only DVM S Cooling Only

DVMS OUTDOOR UNITS


Model Code AM740MXVAGC/TS AM760MXVAGC/TS AM780MXVAGC/TS Model Code AM860MXVAGC/TS AM880MXVAGC/TS AM900MXVAGC/TS
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 74.00 76.00 78.00 HP 86.00 88.00 90.00
Capacity Cooling [kW] 207.20 212.80 218.40 Capacity Cooling [kW] 240.80 246.60 252.00
Cooling [Btu/hr] 707,000 726,100 745,200 Cooling [Btu/hr] 821,600 841,400 859,900
Power Input Cooling [kW] 65.69 63.88 67.42 Power Input Cooling [kW] 74.07 76.05 78.99
Cooling [kW] 105.40 102.50 108.10 Cooling [kW] 118.70 121.90 126.60
Current Input MCA [A] 154.00 (MCA) 154.00 (MCA) 169.50 (MCA) Current Input MCA [A] 190.00 (MCA) 195.00 (MCA) 195.00 (MCA)
MFA [A] 175.00 175.00 200.00 MFA [A] 225.00 225.00 225.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.15 3.33 3.24 Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.25 3.24 3.19
Type SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6 Type SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6
Compressor Output [kW x n] (5.18x2)x2 + (7.81x2) (5.18x2) + (6.39x2) + (7.81x2) (5.18x2) + (6.39x2) + (7.81x2) Compressor Output [kW x n] (6.39x2) + (7.81x2)x2 (6.76x2) + (7.81x2)x2 (7.81x2)x3
Model Name DS-GB052FAVB x 4 + DS4GJ5080FVA x 2 DS-GB052FAVB x 2 + DS-GB066FAVB x 2 + DS4GJ5080FVA x 2 DS-GB052FAVB x 2 + DS-GB066FAVB x 2 + DS4GJ5080FVA x 2 Model Name DS-GB066FAVB x 2 + DS4GJ5080FVA x 4 DS-GB070FAVA x 2 + DS4GJ5080FVA x 4 DS4GJ5080FVA x 6
Type Propeller Propeller Propeller Type Propeller Propeller Propeller
Output x n [W] (620.0 x 2) x 3 (620.0 x 2) x 3 (620.0 x 2) x 3 Output x n [W] (620.0 x 2) x 3 (620.0 x 2) x 3 (620.0 x 2) x 3
Fan Air Flow Rate [CMM] 290 x 2 + 340 290 + 320 + 340 290 + 320 + 340 Fan Air Flow Rate [CMM] 320 + 340 x 2 340 x 3 340 x 3
External Static Pressure [mmAq] 8.00 8.00 8.00 External Static Pressure [mmAq] 8.00 8.00 8.00

DVM S INDOOR UNITS


External Static Pressure [Pa] 78.45 78.45 78.45 External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 22.22 22.22 22.22 Liquid Pipe [Φ, mm] 22.22 22.22 22.22
Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8" Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8"
Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98 Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98
Connections Gas Pipe [Φ, inch] 2 1/8" 2 1/8" 2 1/8" Connections Gas Pipe [Φ, inch] 2 1/8" 2 1/8" 2 1/8"
Installation Limitation [Max Length] [m] 200 200 200 Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0 Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 72.0 72.0 72.0 Sound Pressure [dB(A)] 73.0 74.0 74.0
Sound Sound
Sound Power [dB(A)] 94.0 94.0 94.0 Sound Power [dB(A)] 94.0 95.0 95.0
Net Weight [kg] 280.0 x 2 + 342.0 280.0 + 322.0 + 342.0 280.0 + 330.0 + 342.0 Net Weight [kg] 330.0 + 342.0 x 2 335.0 + 342.0 x 2 342.0 x 3
External Shipping Weight [kg] 299.0 x 2 + 364.0 299.0 + 344.0 + 364.0 299.0 + 352.0 + 364.0 External Shipping Weight [kg] 352.0 + 364.0 x 2 357.0 + 364.0 x 2 364.0 x 3
Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,695 x 765) x 2 + 1,295 x 1,795 x765 1,295 x 1,695 x 765 + (1,295 x 1,795 x 765) x 2 1,295 x 1,695 x 765 + (1,295 x 1,795 x 765) x 2 Dimension Net Dimensions (WxHxD) [mm] (1,295 x 1,795 x 765) x 3 (1,295 x 1,795 x 765) x 3 (1,295 x 1,795 x 765) x 3
Shipping Dimensions (WxHxD) [mm] (1,363 x 1,887 x 832) x 2 + 1,363 x 1,987 x 832 1,363 x 1,887 x 832 + (1,363 x 1,987 x 832) x 2 1,363 x 1,887 x 832 + (1,363 x 1,987 x 832) x 2 Shipping Dimensions (WxHxD) [mm] (1,363 x 1,987 x 832) x 3 (1,363 x 1,987 x 832) x 3 (1,363 x 1,987 x 832) x 3
Operating Operating
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0 Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Temp. Range Temp. Range

DVM S Cooling Only

CAC
Model Code AM800MXVAGC/TS AM820MXVAGC/TS AM840MXVAGC/TS
Power Supply (Outdoor Unit) [Φ, #, V, Hz] 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 80.00 82.00 84.00
Capacity Cooling [kW] 224.20 229.60 235.20
Cooling [Btu/hr] 765,000 783,400 802,500
Power Input Cooling [kW] 69.40 72.34 70.53
Cooling [kW] 111.30 116.00 113.10
Current Input MCA [A] 174.50 (MCA) 174.50 (MCA) 174.50 (MCA)
MFA [A] 200.00 200.00 200.00
Energy Efficiency Ratio EER (Nominal Cooling) [kW/kW] 3.23 3.17 3.33
Type SSC Scroll x 6 SSC Scroll x 6 SSC Scroll x 6
Compressor Output [kW x n] (5.18x2) + (6.76x2) + (7.81x2) (5.18x2) + (7.81x2)x2 (6.39x2) + (7.81x2)x2
Model Name DS-GB052FAVB x 2 + DS-GB070FAVA x 2 + DS4GJ5080FVA x 2 DS-GB052FAVB x 2 + DS4GJ5080FVA x 4 DS-GB066FAVB x 2 + DS4GJ5080FVA x 4
Type Propeller Propeller Propeller
Output x n [W] (620.0 x 2) x 3 (620.0 x 2) x 3 (620.0 x 2) x 3
Fan Air Flow Rate [CMM] 290 + 340 x 2 290 + 340 x 2 320 + 340 x 2

FJM
External Static Pressure [mmAq] 8.00 8.00 8.00
External Static Pressure [Pa] 78.45 78.45 78.45
Liquid Pipe [Φ, mm] 22.22 22.22 22.22
Liquid Pipe [Φ, inch] 7/8" 7/8" 7/8"
Piping Gas Pipe [Φ, mm] 53.98 53.98 53.98
Connections Gas Pipe [Φ, inch] 2 1/8" 2 1/8" 2 1/8"
Installation Limitation [Max Length] [m] 200 200 200
Installation Limitation [Max Height] [m] 110.0 110.0 110.0
Sound Pressure [dB(A)] 73.0 73.0 73.0
Sound
Sound Power [dB(A)] 94.0 94.0 94.0
Net Weight [kg] 280.0 + 335.0 + 342.0 280.0 + 342.0 x 2 322.0 + 342.0 x 2
External Shipping Weight [kg] 299.0 + 357.0 + 364.0 299.0 + 364.0 x 2 344.0 + 364.0 x 2
Dimension Net Dimensions (WxHxD) [mm] 1,295 x 1,695 x 765 + (1,295 x 1,795 x 765) x 2 1,295 x 1,695 x 765 + (1,295 x 1,795 x 765) x 2 (1,295 x 1,795 x 765) x 3

CONTROL SYSETM
Shipping Dimensions (WxHxD) [mm] 1,363 x 1,887 x 832 + (1,363 x 1,987 x 832) x 2 1,363 x 1,887 x 832 + (1,363 x 1,987 x 832) x 2 (1,363 x 1,987 x 832) x 3
Operating
Cooling [ ℃] -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0
Temp. Range

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer. * If you wish to install an outdoor unit module with a capacity of over 66 HP, then please contact your local Samsung Dealer.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m. 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB, Equivalent refrigerant piping : 7,5m, Level differences: 0m.
2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 2) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.) 3) If outdoor unit is located in a higher position than indoor unit, level difference is 110m or under. (if level difference is higher than 50m, make a decision simulating by PDM kit installation guide software (whether the PDM kit should be installed or not.)
*PDM kit: Pressure Drop Modulation kit *PDM kit: Pressure Drop Modulation kit
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 43 44 www.samsung.com/business


DVM S HR DVM S HR

INTRODUCTION
SPECIFICATION SPECIFICATION

DVMS OUTDOOR UNITS


DVM S (Heat Recovery) DVM S (Heat Recovery)

DVM S INDOOR UNITS


CAC
FJM
* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB
2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
3) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB
3) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 45 46 www.samsung.com/business
DVM S HR DVM S ECO

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S ECO
Model Code

DVMS OUTDOOR UNITS


1, 2, 220-240, 50 1, 2, 220-240, 50 1, 2, 220-240, 50
HP 4 5 4
DVM S (Heat Recovery) Capacity 12.1 14.0 12.1
41,200 48,000 41,200
Maximum number of connectible indoor units 6 8 6

Power Input 3.60 4.00 2.89

17.5 19.5 14.0

Current Input 24.0 27.0 22.0


32.0 40.0 32.0

3.36 3.50 4.19


Ratio

Type Twin BLDC Rotary Twin BLDC Rotary Twin BLDC Rotary
Compressor 4.12 4.12 4.12
Model Name
Type Propeller Propeller Propeller

DVM S INDOOR UNITS


125 x 1 139 x 1 125 x 2
Fan
64.00 70.00 100.00
3.00 3.00 3.00
29.40 29.40 29.40
9.52 9.52 9.52
15.88 15.88 15.88

Piping 5/8 5/8 5/8


Connections

30 30 50
Sound 52 55 50
External Dimen- 79 83.5 100
940 x 998 x 330 940 x 998 x 330 940 x 1,210 x 330

Operating °C -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0


Temp. Range

DVM S ECO

CAC
Model Code AM040FXMDGH/TK AM050FXMDEH/TK AM050FXMDGH/TK
3,4,380-415,50 1, 2, 220-240, 50 3,4,380-415,50
HP 4 5 5
12.1 14.0 14.0
Capacity 41,200 47,800 47,800
Maximum number of connectible indoor units 6 8 8

Power Input 2.99 3.69 3.69

4.8 17.9 6. 2

Current Input 10.0 24.0 12.0


20.0 32.0 20.0
4.05 3.79 3.79
Ratio 4.47 4.43 4.43
Type Twin BLDC Rotary Twin BLDC Rotary Twin BLDC Rotary
Compressor 4.12 4.12 4.12
Model Name

FJM
Type Propeller Propeller Propeller
125 x 2 125 x 2 125 x 2
Fan
100.00 100.00 100.00
3.00 3.00 3.00
* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. 29.40 29.40 29.40
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB 9.52 9.52 9.52
2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB
Piping 15.88 15.88 15.88
3) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. Connections 150 150 150
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.
50 50 50
Sound 50 51 51
External Dimen- 100 100 100

CONTROL SYSETM
940 x 1,210 x 330 940 x 1,210 x 330 940 x 1,210 x 330

Operating °C -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0


Temp. Range

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB
* The maximum height of installation limitation for piping connections is only allowable when using PDM kits. PDM kit: Pressure Drop Modulation kit
* MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 47 48 www.samsung.com/business


DVM S ECO DVM S ECO

INTRODUCTION
SPECIFICATION SPECIFICATION

DVM S ECO DVM S ECO Anti Corrosion

DVMS OUTDOOR UNITS


Model Code AM080FXMDGC/EA
1, 2, 220-240, 50 3,4,380-415,50 3,4,380-415,50
HP 6 6 8
Capacity 15.5 15.5 22.4
52,900 52,900 76,400
Maximum number of connectible indoor units 9 9 13

Power Input 4.31 4.31 5.72

21.0 7.3 9.7

Current Input 32.0 12.0 18.0


40.0 20.0 25.0

3.60 3.60 3.92


Ratio

Type Twin BLDC Rotary Twin BLDC Rotary Inverter Scroll


Compressor 4.12 4.12 4.96

DVM S INDOOR UNITS


Model Name DS-GB052FAVAD
Type Propeller Propeller Propeller
125 x 2 125 x 2 180 x 2
100.00 100.00 135.00
Fan
3.00 3.00 3.00
29.40 29.40 29.40
9.52 9.52 9.52

Piping 19.05 19.05 19.05


Connections 150 150 100
50 50 30
Sound 53 53 56
External Dimen- 103 103 135
940 x 1,210 x 330 940 x 1,210 x 330 940 x 1,420 x 330

Operating °C -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0


Temp. Range

DVM S ECO DVM S ECO Anti Corrosion

CAC
Model Code AM100KXMDGH/TK AM120KXMDGH/TK AM140KXMDGH/TK
3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
HP 10 12 14
Capacity 28.0 33.5 40.0
95,500 114,300 136,500
Maximum number of connectible indoor units 18 21 26

Power Input 7. 29 8.7 7 10.59

11.5 13.7 16.5

Current Input 21.5 23.5 32.0


30.0 30.0 40.0

3.84 3.82 3.78


Ratio

Type Inverter Scroll Inverter Scroll Inverter Scroll


5.18 6.39 6.76

FJM
Compressor Model Name DS-GB052FAVB DS-GB066FAVB DS-GB070FAVA
Type Propeller Propeller Propeller
244 x 2 244 x 2 244 x 2
165.00 166.00 180.00
Fan
3.00 3.00 3.00
29.40 29.40 29.40
9.52 12.7 12.7

Piping 22.22 28.58 28.58


Connections 160 160 160
40 40 40
Sound 58 59 62
External Dimen-

CONTROL SYSETM
145 155 162
940 x 1,630 x 460 940 x 1,630 x 460 940 x 1,630 x 460

Operating °C -5.0 ~ 48.0 -5.0 ~ 48.0 -5.0 ~ 48.0


Temp. Range
* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB
* Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB * The maximum height of installation limitation for piping connections is only allowable when using PDM kits. PDM kit: Pressure Drop Modulation kit
* The maximum height of installation limitation for piping connections is only allowable when using PDM kits. PDM kit: Pressure Drop Modulation kit * MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.
* MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

2017 Samsung Air Conditioning Solutions 49 50 www.samsung.com/business


DVM CHILLER DVM CHILLER

INTRODUCTION
SPECIFICATION SPECIFICATION

DVMS OUTDOOR UNITS


(Without Pump) (With Pump)

DVM S INDOOR UNITS


CAC
FJM
* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB
2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB 2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB
3) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions. 3) Sound level was acquired in an anehonic room. Thus actual noise level may be different depending on the installation conditions.
4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps. 4) MCA : Minimum Circuit Amps, MFA: Maximum Fuse Amps.

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 51 52 www.samsung.com/business
INTRODUCTION
DVMS OUTDOOR UNITS
DVM S INDOOR UNITS
CAC
* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB 1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB
2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB 2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB

FJM
CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 53 54 www.samsung.com/business
INTRODUCTION
DVMS OUTDOOR UNITS
DVM S
INDOOR UNITS

* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB
2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB

2017 Samsung Air Conditioning Solutions 55 56 www.samsung.com/business


DVM S 360 CASSETTE

INTRODUCTION
INDOOR LINE-UP
CASSETTE

Model

360 Cassette 4 Way 4 Way (600x600) 1 Way 2 Way

DVMS OUTDOOR UNITS


2.2

2.8

3.2

3.6

4.5
Capacity
(kW) 5.6

6.0

7.1

9.0

11.2

12.8

14.0

DVM S INDOOR UNITS


CONSOLE, CEILING & FLOOR STANDING

Model
Floor Standing Floor Standing Ceiling Console
2.8

Capacity 3.6
(kW)
5.6
7.1
14
28

The circular-shaped 360 Bladeless Cassette is Samsung’s latest innovative design for air conditioning indoor
DUCT
Model
standard for multi-directional cassette units.
Duct S Slim Duct MSP Duct HSP Duct Big Duct

2.2

Evenly circulates & cools every corner

CAC
2.8

3.6

4.5

5.6

Capacity
7.1
an optimal even cooling performance without creating cold draft. A circular outlet discharges cool air in all
(kW) 9.0

11.2

12.8

14.0 Conventional 360 Cassette


16.0

18.0

22.4

FJM
28.0

WALL MOUNTED
Model
AR5000 Boracay
1.5

2.2

2.8

CONTROL SYSETM
3.6
Capacity
(kW) 4.5

5.6

7. 1 Booster Fan

8.2

2017 Samsung Air Conditioning Solutions 57 58 www.samsung.com/business


360 CASSETTE 4 WAY CASSETTE

INTRODUCTION
Comfort Cooling

DVMS OUTDOOR UNITS


Circular LED Display Window

DVM S INDOOR UNITS


The 360 Bladeless Cassette combines revolutionary
performance with an elegant design which will
blend in and enhance any setting. The unit features a
stylish panel and intuitive LED display that allows
users to change the
4-Way Cassette great for residential and light commercial applications with limited roof space.

Samsung 4-way cassette enables users to manipulate the angles of

Users can individually set the opening angles of the four blades at
Circular to Perfectly Fit in Everywhere
the same angle or different angles (32° - 65°) to create the right
cooling environment.

CAC
the style of any
room. Lightweight build 4 Way Cassette Conventional

The Samsung 4 Way Cassette indoor unit is now lighter in weight at


40%
All round simpler & intuitive control
percent lighter than conventional products.
Premium Dial Remote Control 17kg 29kg

Users have the option of a wheel dial wireless remote controller with a

FJM
dedicated button for comfort cooling.

Virus Doctor Kit


4 Way Cassette Conventional

3.6m
4.6m

CONTROL SYSETM
Wi-Fi Kit
ceilings of up to 3.6m. And the high ceiling mode delivers even more
Users also have the option to add on a Wi-Fi® Kit to remotely control their

2017 Samsung Air Conditioning Solutions 59 60 www.samsung.com/business


4 WAY CASSETTE 1 WAY CASSETTE

INTRODUCTION
Slim and Quiet
Samsung's aerodynamically designed Turbo Fan minimises blade

DVMS OUTDOOR UNITS


maintenance easier.
conventional models. The Turbo Fan's wide blades also provide These high-performing units are so subtle that they can blend
evenly distributed cool air from four separate outlets so that the seamlessly into interiors of any types and styles.
entire room can cool down faster.

31kg

Weight
9.9kg
Easy Blade Cleaning
Lighter Indoor Unit

Conventional

DVM S INDOOR UNITS


Samsung applies ABS cabinets into its 1-Way Cassette to

DVM S
provide a light weight (10.5kg) indoor unit. The slim and
maintenance even easier. light weight design makes installation and maintenance
a breeze.
3.6 kW R410A model
* Excluding panel

Noise level
26%
Quiet Operation
30dB Down

25dB 32%
Down
Complement any interior with a sleek, Classic Pattern
work place
lightweight design

SAMSUNG

Company A

SAMSUNG
is not only more comfortable for employees but also aids
The new Samsung 4 Way Cassette indoor air conditioner comes in a productivity. Whether operating on high or
choice of patterns with a simple panel to better match the interior

CAC
Low Fan Speed High Fan Speed
clever blade construction keeps the unit clean for a tidy appearance.

Check valve:
Prevents drain water
OPTIONAL FEATURES from reversing

Minimizes
Virus Doctor Kit Remaining
Drain Water
drain water that could drip into
Samsung’s Virus Doctor device generates active hydrogen H your interior space.
Eliminates Complete Neutralize Freedom from W

contaminants and active oxygen (OH-radical) in the air by Subtype H1N1 Bacteria Active Oxygen Allergens

FJM
Virus Eradication
turning them into harmless H2O. This optional device can be
easily installed by inserting into the indoor unit.
ONE-WAY FLOW CLEAN CEILING NO OVERFLOW NO STAGNATION

Virus Doctor Kit

Wi-Fi Kit

CONTROL SYSETM
Wi-Fi and Wi-Fi Direct® are registered trademarks of Wi-Fi Alliance.

2017 Samsung Air Conditioning Solutions 61 62 www.samsung.com/business


2 WAY CASSETTE MSP CEILING DUCTED

INTRODUCTION
Compact But Powerful Powerful and Flexible

DVMS OUTDOOR UNITS


create a pleasant environment for you.

Ideal for Long and Narrow Places


Strong and Large Coverage Area MSP Duct LSP Duct
45%
Decreased
The MSP Ceiling Ducted design has the advantage of producing
greater static pressure than most other Samsung
space-saving as compared to
conventional 4-Way cassette.
305mm 230mm

DVM S INDOOR UNITS


600mm 1,180mm 575mm
890mm
0~25mmAq 0~6mmAq

Conventional 2Way Cassette


servicing more people with more cool air.

Narrow Width
1030mm
The 2Way Cassette unit dimensions allow for easy installation into
standard ceiling grids (600W x 600D) for a
650mm

600mm

900mm

*Measured without control box.


600mm

Cross Flow Fans


Twin Cross Flow Fan

CAC
rooms of any dimension so no corner is overlooked.

20o
Auto Surround Swing
60o

The External Static Pressure Control combines with the simplicity of the MSP Ceiling Ducted’s design to

keeping your environment pleasant and comfortable.

FJM
2Way Cassette Conventional

minimal disturbance that it is conducive for use at night-time when sleeping.


Optimum Temperature Control
The Optimum Temperature Control function detects and 18OC
minimises temperature difference between the top and 19OC
Easy to Maintain
A 20OC Time and maintenance costs are reduced as you can easily remove

CONTROL SYSETM
A
the bottom panel to access and service the parts.

* C
O

2017 Samsung Air Conditioning Solutions 63 64 www.samsung.com/business


HSP CEILING DUCTED SLIM CEILING DUCTED

INTRODUCTION
Powerful and Flexible Silent and Flexible

DVMS OUTDOOR UNITS


ceiling.

25mmAq Rear Side Air Inlet Bottom Side Air Inlet

20mmAq
Company A
HSP Duct

HSP Duct

Diffuser

Diffuser
TEX
TEX

Flexible Installation
Suction Duct
Suction Duct

11.2 ~ 14kW 22.4kW / 28kW

DVM S INDOOR UNITS


HSP Duct LSP Duct

Strong and Large Coverage Area surrounding space.


HSP Ceiling Ducted features greater static pressure than
most of slim ducts. This enables you to design more inlets
and outlets with longer duct work to provide more cool air 0~25mmAq 0~6mmAq Easier Drain Pump Installation
to larger areas.

CAC
Various installation options

World’s lightest weight

900mm

FJM
Silent Operation with the Static Pressure Control
700mm 200 mm
Narrower

Easy access, easy maintenance


Easy to Maintain

CONTROL SYSETM
Time and maintenance costs are reduced since parts are easily
accessible by removing the button panel.

2017 Samsung Air Conditioning Solutions 65 66 www.samsung.com/business


OAP CEILING DUCTED

INTRODUCTION
AR5000 SERIES

Samsung’s new Outdoor Air Processing Ceiling Ducted (OAP) is an outside

DVMS OUTDOOR UNITS


fresh air treatment unit with integrated

Air conditioning indoor units and an Outdoor Air Processing Ceiling Ducted
unit can be connected to the same
Triangular Architecture for Powerful Cooling
extends the saving with lower energy consumption.

Wide Operation Range


Outdoor Air Processing Ceiling Ducted can supply fresh air to the interior area through cooling or heating

DVM S INDOOR UNITS


Cools Faster, Farther, and Wider

Heating Ventilating Cooling


also ensure that air is cooled and expelled faster and further. So that refreshingly cool air can reach every corner
of your room.
Flexible Installation
Height
390mm

a variety of areas and installation options. TEX

CAC
Noise Level
Quiet Operation
55dB(A)

42dB(A)
40dB(A) 39%* wider air inlet 22%* bigger fan blower 54%* wider air outlet
Silver Coated Filter More Air Flow More Air Out
O.A.P Duct
Office

Library

*Compared against Samsung conventional model AQV09TWS.


cooling comfort.
* Comparison is based on 5HP Duct.
Easy Clean Filter

Flexible Static Pressure Control

FJM
Low Static
Pressure

Standard

High Static
Pressure

CONTROL SYSETM
Samsung Conventional
percent more energy than conventional products for more economical and practical operation.

2017 Samsung Air Conditioning Solutions 67 68 www.samsung.com/business


CONSOLE CEILING

INTRODUCTION
Slim and Elegant Console
The slim and elegant Samsung Console indoor unit is designed to

DVMS OUTDOOR UNITS


maintaining an optimal indoor temperature. Samsung’s console air
conditioning solution makes any environment more pleasant and

Slim Design Slim yet Functional Ceiling Unit

design easily integrates into any decor.

DVM S INDOOR UNITS


Small package, big performance

larger units.

2-Way Installation Under Ceiling Floor Standing


Depending on the available space and the purpose
Stay-clean

CAC
Sophisticated Control
Fast Cooling, Long Distance e Wind

a single BLDC motor to reduce noise.


2-Way Air Outlets

FJM
There are two separate air outlets for cooling and heating. The cooling air comes out from the upper part of the
air to reach every corner of the room.

Simple Display
The simple display design with its rounded corners adds a neat and tidy feeling to your interior.

CONTROL SYSETM
- Red : Error
- Orange : Filter Alarm
Time Limit + Operating Pattern

2017 Samsung Air Conditioning Solutions 69 70 www.samsung.com/business


CONCEALED FLOOR STANDING

INTRODUCTION
Super
provides strong and

DVMS OUTDOOR UNITS


long-range cooling with reliable performance.

it cools a large room in an instance.


Samsung Concealed Floor Standing unit offers the utmost in versatility in solving your cooling and heating

DVM S INDOOR UNITS


Duct installation for a large space

Effective Cooling System

high ceilings and windows conditions while delivering consistent cooling performance.

Mirage
The superior technologies built in provide the
experience of absolute comfort.

CAC
School Hotel
4 Way auto swing
There’s no need for two air conditioners to cool one large area if you use Mirage.
Silent operation 4 Way Auto Swing cools every

makes spaces more comfortable and carefree than ever before.

Full touch panel control

FJM
78dBA

55dBA
50dBA Less modern luxury to your room.
40dBA Noise
27dBA
Keyboard Typing

Voice chatting

Library

Concealed

CONTROL SYSETM
Auto shutter

Noise Level Comparison


not in use.

2017 Samsung Air Conditioning Solutions 71 72 www.samsung.com/business


HYDRO UNIT ERV PLUS/ERV

INTRODUCTION
DVMS OUTDOOR UNITS
headaches and dizziness.

DVM S INDOOR UNITS


The Samsung ERV (Energy Recovery Ventilation) system air conditioner provides fresh and healthy air from

Drive energy savings with unparalleled heat exchange and automated


temperature control
Samsung ERV and ERV Plus deliver exceptional cooling and heating all year round by employing the following
heat recovery method:
Streamline operation with all-in-one cooling and heating
1.

2. The remaining surface of the heat exchange area transfers heat energy while preventing the discharged contaminants

CAC
from re-entering.

Integrated cooling and heating 3.

indoors during the summer.

Auto Mode

connections with BACnet and LonWorks interface kits.

FJM
Extreme Climates Mild Climates
(Winter and Summer) (Spring and Fall)

Damper Damper

Exhaust Air Return Air Exhaust Air Return Air

Outdoor Air Supply Air Outdoor Air Supply Air

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 73 74 www.samsung.com/business
ERV PLUS/ERV AH U KIT

INTRODUCTION
Smart CO2 Detection
2 with the optional CO2 Sensor. Users can also attach a

DVMS OUTDOOR UNITS


savings and improved performance and effectivity.
level.
Features includes:

Variable capacity
Moisture Heat O 2 O2 CO CO
2.5HP - 40HP
O2
Heat Recovered
and Fresh Air
Polluted CO Simple BMS application
and Cold Air

O2

DVM S INDOOR UNITS


CO
0-10V
O2
CO

Discharge air temperature control


Dust

Polluted Cold and Dry Air


and Humid Air

Outdoor unit
Indoor Outdoor Communication F1, F2
element
Direct
O2 Expansion
Heat Recovered Coil
CO
EEV Kit
Polluted
and Fresh Air and Cold Air
CO
O2
O2
CO EEV Control
Dust
Liquid Pipe

CAC
Polluted Cold and Dry Air
and Humid Air

Eva in AHU Fan Control


Sensor Sensor
Flexible Setup*
Exhaust Return Return Air Exhaust Air Fresh Air Supply Air
The ERV system can be installed vertically or horizontally. This Air Air

FJM
more than one unit. Users can reduce the number of service holes Room
Sensor
by installing ERV with the control box facing a single service hole
Outdoor Supply
(applicable to ERV only). Air Air Fan Feedback

Space for
service AHU Controller

Outdoor Supply
Air Air Gas pipe
Eva_out Sensor

CONTROL SYSETM
Reversed
installation

Exhaust Return
Air Air

2017 Samsung Air Conditioning Solutions 75 76 www.samsung.com/business


DVM S

INTRODUCTION
SPECIFICATION

DVM S 360 Cassette


Model Code AM045KN4DEH AM056KN4DEH AM071KN4DEH

DVMS OUTDOOR UNITS


INDOOR UNIT
System Mode HP/HR HP/HR HP/HR

4.5 5.6 7.1


Capacity

SPECIFICATION
Power Input 26 30 34

Current Input 0.18 0.21 0.25

Type Turbo Fan Turbo Fan Turbo Fan

Fan 65 x 1 65 x 1 65 x 1

14.50 / 13.50 / 12.50 16.00 / 14.50 / 13.50 18.00 / 16.00 / 14.00

6.35 6.35 9.52

12.7 12.7 15.88


tions

DVM S INDOOR UNITS


Drain Pipe

Sound 33 / 31 / 29 34 / 32 / 29 36 / 33 / 30

21.0 21.0 21.0


sion (Outdoor
Unit) 947 x 281 x 947 947 x 281 x 947 947 x 281 x 947

Panel Model PC4NUDMAN PC4NUDMAN PC4NUDMAN

Panel Net Weight 3.6 3.6 3.6

Net Dimension (WxHxD)

360 Cassette
Model Code AM090KN4DEH AM112KN4DEH AM128KN4DEH

CAC
System Mode HP/HR HP/HR HP/HR

9.0 11.2 12.8


Capacity

Power Input 55 53 77

Current Input 0.42 0.41 0.62

Type Turbo Fan Turbo Fan Turbo Fan

Fan 65 x 1 97 x 1 97 x 1

22.00 / 18.50 / 16.00 25.50 / 21.00 / 17.50 29.50 / 24.00 / 19.00

9.52 9.52 9.52

tions 15.88 15.88 15.88

Drain Pipe

FJM
Sound 40 / 36 / 32 40 / 36 / 32 42 / 38 / 33

21.0 24.0 24.0


sion (Outdoor
Unit) 947 x 281 x 947 947 x 365 x 947 947 x 365 x 947

Panel Model PC4NUDMAN PC4NUDMAN PC4NUDMAN

Panel Net Weight 3.6 3.6 3.6

Net Dimension (WxHxD)

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Panel
Controllers (Optional)
(Optional)

PC4NUDMAN PC4NBDMAN PC4NUNMAN PC4NBNMAN


(360 CST dedicated)

2017 Samsung Air Conditioning Solutions 77 78 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

360 Cassette 4 Way Cassette (600 X 600 )


Model Code AM140KN4DEH Model Code AM036FNNDEH AM045FNNDEH AM056FNNDEH AM060FNNDEH

DVMS OUTDOOR UNITS


System Mode HP/HR System Mode HP/HR HP/HR HP/HR HP/HR

14.0 3.6 4.5 5.6 6


Capacity Capacity

Power Input 91 Power Input 20 23 28 31

Current Input 0.75 Current Input 0.19 0.22 0.27 0.3

Type Turbo Fan Type Turbo Fan Turbo Fan Turbo Fan Turbo Fan
Fan
97 x 1 65 x 1 65 x 1 65 x 1 65 x 1
Fan

31.50 / 26.50 / 21.00 10.5 / 9.5 / 8.0 11.5 / 10.2 / 9.0 13.0 / 11.0 / 9.5 13.5 / 12.0 / 10.2

9.52 6.35 6.35 6.35 6.35

15.88 12.7 12.7 12.7 12.7


tions tions

DVM S INDOOR UNITS


Drain Pipe Drain Pipe

44 / 40 / 35 Sound 34 / 30 /26 36 / 34 / 32 39 / 36 / 33 40 / 38 / 35
Sound

24.0 12.0 12.0 12.0 12.0


sion (Outdoor sion (Outdoor
Unit) Unit) 575 x 250 x 575 575 x 250 x 575 575 x 250 x 575 575 x 250 x 575
947 x 365 x 947

Panel Model PC4NUDMAN Panel Model PC4SUSMAN PC4SUSMAN PC4SUSMAN PC4SUSMAN

Panel Net Weight 3.6 Panel Net Weight 2.7 2.7 2.7 2.7

Net Dimension (WxHxD) Net Dimension (WxHxD) 670 x 45 x 670 670 x 45 x 670 670 x 45 x 670 670 x 45 x 670

4 Way Cassette S (600 X 600) 4 Way Cassette


Model Code AM015HNNDEH AM022FNNDEH AM028FNNDEH Model Code AM045FN4DEH AM056FN4DEH AM071FN4DEH

CAC
System Mode HP/HR HP/HR HP/HR System Mode HP/HR HP/HR HP/HR

1.5 2. 2 2.8 4.5 5.6 7.1


Capacity Capacity

Power Input 18 18 18 Power Input 32 32 45

Current Input 0.17 0.17 0.17 Current Input 0.22 0.22 0.31

Type Turbo Fan Turbo Fan Turbo Fan Type Turbo Fan Turbo Fan Turbo Fan
Fan
Fan 65 x 1 65 x 1 65 x 1 65 x 1 65 x 1 65 x 1

8.2 / 7.0 / 6.3 9.0 / 7.7 / 6.5 10.0 / 8.5 / 7.5 14.5 / 13.5 / 12.5 15.0 / 14.0 / 13.0 17.0 / 15.5 / 14.5

6.35 6.35 6.35 6.35 6.35 9.52

12.7 12.7 12.7 12.7 12.7 15.88


tions tions
Drain Pipe Drain Pipe

FJM
Sound 30 / 28 / 23 32 / 29 / 25 33 / 30 / 26 Sound 33 / 32 / 30 33 / 32 / 30 35 / 34 / 33

12.0 12.0 12.0 15.5 15.5 15.5


sion (Outdoor sion (Outdoor
Unit) 575 x 250 x 575 575 x 250 x 575 575 x 250 x 575 Unit) 840 x 204 x 840 840 x 204 x 840 840 x 204 x 840

Panel Model PC4SUSMAN PC4SUSMAN PC4SUSMAN Panel Model PC4NUSKAN PC4NUSKAN PC4NUSKAN

Panel Net Weight 2.7 2.7 2.7 Panel Net Weight 5.8 5.8 5.8

Net Dimension (WxHxD) 670 x 45 x 670 670 x 45 x 670 670 x 45 x 670 Net Dimension (WxHxD) 950 x 45 x 950 950 x 45 x 950 950 x 45 x 950

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Panel Individual Panel
Controllers (Optional) Controllers (Optional)
(Optional) (Optional)

PC4SUSMAN PC4SUSMEN PC4NUSKAN PC4NBSKAN PC4NUSKEN


(360 CST dedicated) (360 CST dedicated)

2017 Samsung Air Conditioning Solutions 79 80 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

4 Way Cassette 1 Way Cassette


Model Code AM090FN4DEH AM112FN4DEH AM128FN4DEH AM140FN4DEH Model Code AM028FN1DEH AM036FN1DEH AM056JN1DEH AM071JN1DEH

DVMS OUTDOOR UNITS


System Mode HP/HR HP/HR HP/HR HP/HR System Mode HP/HR HP/HR HP/HR HP/HR

9.0 11.2 12.8 14.0 2.8 3.6 5.6 7.1


Capacity Capacity

Power Input 62 78 73 89 Power Input 45 50 55 80

Current Input 0.43 0.55 0.51 0.62 Current Input 0.23 0.25 0.28 0.4

Type Turbo Fan Turbo Fan Turbo Fan Turbo Fan Type
Fan
65 x 1 65 x 1 97 x 1 97 x 1 17 x 1 17 x 1 54 x 1 54 x 1
Fan
19.5 / 18.0 / 16.5 26.0 / 24.0 / 22.0 28.0 / 26.0 / 23.0 30.0 / 28.0 / 26.0 7.00 / 6.00 / 5.00 8.00 / 7.00 / 6.00 16.00 / 14.00 / 12.50 17.00 / 15.50 / 14.00

9.52 9.52 9.52 9.52 6.35 6.35 6.35 9.52

15.88 15.88 15.88 15.88 12.7 12.7 12.7 15.88


tions tions

DVM S INDOOR UNITS


Drain Pipe Drain Pipe

Sound 39 / 36 / 33 40 / 38 / 35 42 / 40 / 35 44 / 41 / 35 Sound 29 / 27 / 24 35 / 31 / 27 36 / 33 / 31 39 / 37 / 34

15.5 17.0 19.0 19.0 10.5 10.5 14.5 14.5


sion (Outdoor sion (Outdoor
Unit) 840 x 204 x 840 840 x 246 x 840 840 x 288 x 840 840 x 288 x 840 Unit) 970 x 135 x 410 970 x 135 x 410

Panel Model PC4NUSKAN PC4NUSKAN PC4NUSKAN PC4NUSKAN Panel Model PC1NUSMAN PC1NUSMAN PC1BWSMAN PC1BWSMAN

Panel Net Weight 5.8 5.8 5.8 5.8 Panel Net Weight 3 3 6.3 6.3

Net Dimension (WxHxD) 950 x 45 x 950 950 x 45 x 950 950 x 45 x 950 950 x 45 x 950 Net Dimension (WxHxD)

1 Way Cassette 2 Way Cassette


Model Code AM017HN1DEH AM022FN1DEH AM022HN1DEH Model Code AM056FN2DEH AM071FN2DEH

CAC
System Mode HP/HR HP/HR HP/HR System Mode HP/HR HP/HR

1.7 2. 2 2. 2 5.6 7.1


Capacity Capacity

Power Input 24 24 25 Power Input 70 75

Current Input 0.14 0.2 0.15 Current Input 0.38 0.4

Type Type
Fan Fan
27 x 1 17 x 1 27 x 1 14 14

4.80 / 4.30 / 4.10 6.00 / 5.00 / 4.00 5.10 / 4.60 / 4.30 14 / 13 / 12 15 / 14 / 13

6.35 6.35 6.35 6.35 9.52

12.7 12.7 12.7 12.7 15.88


tions tions
Drain Pipe Drain Pipe

FJM
Sound 27 / 24 / 21 27 / 25 / 23 27 / 25 / 23 Sound 38 / 37 / 35 41 / 39 / 37

8.0 10.5 8.0 21.0 22.0


sion (Outdoor sion (Outdoor
Unit) 740 x 135 x 360 970 x 135 x 410 740 x 135 x 360 Unit) 890 x 230 x 575 890 x 230 x 575

Panel Model PC1MWSKAN PC1NUSMAN PC1MWSKAN Panel Model PC2NUSMEN PC2NUSMEN

Panel Net Weight 2.6 3 2.6 Panel Net Weight 4 4

Net Dimension (WxHxD) 900 x 25 x 420 900 x 25 x 420 Net Dimension (WxHxD)

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Panel Individual Panel
Controllers (Optional) PC1MWSKAN (1.7~2.2kW) PC1NUSMAN (2.2~3.6kW) PC1NUPMAN (2.2~3.6kW) Controllers (Optional)
(Optional) PC1NWSMAN (2.2~3.6kW) PC1BWSEAN (5.6~7.1kW) PC1BWPEAN (5.6~7.1kW) (Optional)
PC1BWSMAN (5.6~7.1kW)
Fluid type Classic type Sliding type PC2NUSMEN
(360 CST dedicated)

2017 Samsung Air Conditioning Solutions 81 82 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

Duct S Duct S
Model Code AM036HNMPKH AM045HNMPKH AM056HNMPKH

DVMS OUTDOOR UNITS


System Mode HP/HR HP/HR HP/HR

3.6 4.5 5.6


Capacity

Power Input 50 60 70

Current Input 0.5 0.6 0.7

Type Sirocco Fan Sirocco Fan Sirocco Fan


Fan
153 x 1 153 x 1 153 x 1

12.0 / 9.5 / 8.0 14.0 / 11.0 / 8.0 16.0 / 13.5 / 11.0

6.35 6.35 6.35

DVM S INDOOR UNITS


12.7 12.7 12.7
tions
Drain Pipe

Sound 29 / 26 / 23 31 / 28 / 24 32 / 29 / 25

25.5 25.5 25.5


sion (Outdoor
Unit) 850 x 250 x 700 850 x 250 x 700 850 x 250 x 700

Air Filter Type "Removable / Washable / "Removable / Washable / "Removable / Washable /


Mildew proof" Mildew proof" Mildew proof"

Duct S Duct S
Model Code AM071HNMPKH AM090HNMPKH AM112HNMPKH Model Code

CAC
System Mode HP/HR HP/HR HP/HR

7.1 9.0 11.2


Capacity Capacity

Power Input 120 145 165 Power Input


Current Input 1.0 1.2 1.4 Current Input

Type Sirocco Fan Sirocco Fan Sirocco Fan


Fan Fan
153 x 1 153 x 1 244 x 1

22.0 / 19.0 / 16.0 29.0 / 25.0 / 22.0 35.0 / 29.0 / 22.0

9.52 9.52 9.52

15.88 15.88 15.88


tions tions

FJM
Drain Pipe Drain Pipe

Sound 37 / 33 / 29 38 / 35 / 32 38 / 35 / 32 Sound
25.5 33.0 38.5
sion (Outdoor sion (Outdoor
Unit) 850 x 250 x 700 1200 x 250 x 700 1300 x 300 x 700 Unit)
"Removable / Washable / "Removable / Washable / "Removable / Washable /
Air Filter Type Air Filter Type
Mildew proof" Mildew proof" Mildew proof"

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Drain Individual Drain
Controllers Pump Controllers Pump
(Optional) (Optional) (Optional) (Optional)

(External Type) (External Type)

2017 Samsung Air Conditioning Solutions 83 84 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

Slim Duct Slim Duct


Model Code AM022KNLDEH AM028KNLDEH AM036KNLDEH Model Code AM090KNLDEH AM112KNLDEH AM128KNLDEH AM140KNLDEH

DVMS OUTDOOR UNITS


System Mode HP/HR HP/HR HP/HR System Mode HP/HR HP/HR HP/HR HP/HR

2. 2 2.8 3.6 9.0 11.2 12.8 14.0


Capacity Capacity

Power Input 30 34 40 Power Input 170 170 200 220

Current Input 0.25 0.28 0.33 Current Input 0.96 0.96 1.28 1.43

Type Sirocco Fan Sirocco Fan Sirocco Fan Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan

69 x 1 69 x 1 69 x 1

6.00 / 4.90 / 3.80 7.05 / 5.15 / 4.35 8.20 / 6.50 / 4.90 29.00 / 27.00 / 25.00 31.20 / 29.00 / 27.00 34.00 / 32.00 / 30.00 36.00 / 34.00 / 32.00
Fan Fan
0.0 / 1.0 / 3.0 0.0 / 1.0 / 3.0 0.0 / 1.0 / 3.0 0.00 / 3.00 / 6.00 0.00 / 3.00 / 6.00 0.00 / 3.00 / 6.00 0.00 / 3.00 / 6.00

0.00 / 9.81 / 29.42 0.00 / 9.81 / 29.42 0.00 / 9.81 / 29.42 0.00 / 29.42 / 58.84 0.00 / 29.42 / 58.84 0.00 / 29.42 / 58.84 0.00 / 29.42 / 58.84

DVM S INDOOR UNITS


6.35 6.35 6.35 9.52 9.52 9.52 9.52

12.7 12.7 12.7 tions


15.88 15.88 15.88 15.88

tions Drain Pipe Drain Pipe

Sound 26 / 23 / 19 28 / 24 / 19 31 / 26 / 20 Sound 37 / 36 / 34 37 / 36 / 34 37 / 36 / 34 39 / 38 / 36

15.3 15.3 15.7 40.5 40.5 42.0 42.0


sion (Outdoor sion (Outdoor
Unit) 700 x 199 x 440 700 x 199 x 440 700 x 199 x 440 Unit)

Air Filter Type Air Filter Type

Slim Duct MSP Duct


Model Code AM045KNLDEH AM056KNLDEH AM071KNLDEH

CAC
System Mode HP/HR HP/HR HP/HR

4.5 5.6 7.1


Capacity

Power Input 90 95 120

Current Input 0.52 0.53 0.6

Type Sirocco Fan Sirocco Fan Sirocco Fan

11.00 / 9.60 / 8.30 12.00 / 10.50 / 9.00 16.50 / 15.00 / 13.50


Fan
0.00 / 2.00 / 4.00 0.00 / 2.00 / 4.00 0.00 / 2.00 / 4.00

0.00 / 19.61 / 39.23 0.00 / 19.61 / 39.23 0.00 / 19.61 / 39.23

6.35 6.35 9.52

FJM
12.7 12.7 15.88
tions
Drain Pipe

Sound 35 / 31 / 26 36 / 34 / 31 38 / 36 / 33

24.5 24.5 30.5


sion (Outdoor
Unit) 900 x 199 x 600 900 x 199 x 600

Air Filter Type

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Drain Individual
Individual Drain MDP-E075SEE3D
Controllers Pump Controllers
Controllers Pump MDP-M075SGU1D
(Optional) (Optional) (Optional)
(Optional) (Optional) MDP-M075SGU2D
MDP-M075SGU3D

(Turkish)

2017 Samsung Air Conditioning Solutions 85 86 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

MSP Duct HSP Duct


Model Code AM056KNMDEH AM071KNMDEH AM090KNMDEH Model Code AM112FNHDEH AM128FNHDEH AM140FNHDEH

DVMS OUTDOOR UNITS


System Mode HP/HR HP/HR HP/HR System Mode HP/HR HP/HR HP/HR

5.6 7.1 9.0 11.2 12.8 14.0


Capacity Capacity

Power Input 130 190 240 Power Input 510 560 625

Current Input 1.10 1.25 1.30 Current Input 3.6 3.75 3.9

Type Sirocco Fan Sirocco Fan Sirocco Fan Type Sirocco Fan Sirocco Fan Sirocco Fan

124 124 130

14.50 / 13.00 / 11.50 18.50 / 17.00 / 15.50 19.50 / 18.00 / 16.50 32 / 27 / 23 35 / 31 / 26 39 / 33 / 28


Fan Fan
0.00 / 4.00 / 8.00 0.00 / 4.00 / 8.00 4.00 / 6.00 / 8.00 5.0 / 10.0 / 20.0 5.0 / 10.0 / 20.0 5.0 / 10.0 / 20.0

0.00 / 4.00 / 8.00 0.00 / 39.23 / 78.45 39.23 / 58.84 / 78.45 49.0 / 98.1 / 196.1 49.0 / 98.1 / 196.1 49.0 / 98.1 / 196.1

DVM S INDOOR UNITS


6.35 9.52 9.52 9.52 9.52 9.52

12.7 15.88 15.88 15.88 15.88 15.88


tions tions
Drain Pipe Drain Pipe

Sound 35 / 33 / 31 39 / 35 / 31 40 / 37 / 34 Sound 43 / 41 / 39 45 / 43 / 42 46 / 45 / 44

28.5 28.5 32.5 62.0 62.0 62.0


sion (Outdoor sion (Outdoor
Unit) 900 x 260 x 480 900 x 260 x 480 Unit)

Air Filter Type Air Filter Type

MSP Duct HSP Duct


Model Code AM112KNMDEH AM128KNMDEH AM140KNMDEH AM160KNMDEH1 Model Code AM220FNHDEH AM280FNHDEH

CAC
System Mode HP/HR HP/HR HP/HR HP/HR System Mode HP/HR HP/HR

11.2 12.8 14.0 16.0 22.4 28.0


Capacity

Power Input 260 370 410 485 Power Input 530 790

Current Input 1.17 1.67 1.86 2.24 Current Input 3.8 5.9

Type Sirocco Fan Sirocco Fan Sirocco Fan Sirocco Fan Type Sirocco Fan Sirocco Fan

130 218 218 370

27.00 / 25.00 / 23.00 32.00 / 30.00 / 28.00 37.00 / 34.00 / 31.00 43.00 / 38.00 / 30.50 58 / 52 / 47 72 / 65 / 58
Fan Fan
4.00 / 8.00 / 12.00 4.00 / 8.00 / 14.00 4.00 / 8.00 / 14.00 4.00 / 8.00 / 14.00 5.0 / 15.0 / 25.0 5.0 / 15.0 / 28.0

39.23 / 78.45 / 117.68 39.23 / 78.45 / 137.29 39.23 / 78.45 / 137.29 39.23 / 78.45 / 137.29 49.03 / 147.1 / 245.17 49.03 / 147.1 / 274.59

9.52 9.52 9.52 9.52 9.52 9.52

FJM
15.88 15.88 15.88 15.88 19.05 22.23
tions tions
Drain Pipe Drain Pipe

Sound 41 / 40 / 38 41 / 40 / 38 42 / 39 / 36 43 / 40 / 36 Sound 45 / 43 / 41 48 / 46 / 43

36.0 48.5 48.5 50.5 89.0 89.0


sion (Outdoor sion (Outdoor
Unit) Unit)

Air Filter Type Air Filter Type

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Drain MDP-E075SEE3D Individual Drain Drain
Controllers Pump MDP-M075SGU1D Controllers Pump Pump
(Optional) (Optional) MDP-M075SGU2D (Optional) (Optional) (Optional)
MDP-M075SGU3D

MDP-G075SP MDP-G075SQ MDP-N047SNC1D


(External Type) (Internal Type)

2017 Samsung Air Conditioning Solutions 87 88 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

O.A.P Wall Mounted (AR5000)


Model Code AM140JNEPEH AM220JNEPEH AM280JNEPEH Model Code

DVMS OUTDOOR UNITS


System Mode HP HP HP System Mode HP/HR HP/HR HP/HR
14.0 22.4 28.0 3.6 4.5 5.6
Capacity
Capacity

Power Input 220 300 370


Power Input 20 31 27
Current Input 1.6 2. 2 3
Current Input 0.15 0.24 0.21
Type Sirocco Fan Sirocco Fan Sirocco Fan
Type
183 400 400
Motor 27 27 27
18 28 35 Fan
Fan 7.1 / 5.7 / 4.6 8.9 / 7.5 / 6.0 11.8 / 10.0 / 8.2
5.0 / 20.39 / 25.0 10.0 / 23.45 / 25.0 10.0 / 25.49 / 27.5
6.35 6.35 6.35
49.0 / 199.82 / 245.0 98.0 / 229.81 / 245.0 98.0 / 249.8 / 269.5
1/4 1/4 1/4
9.52 9.52 9.52

DVM S INDOOR UNITS


12.7 12.7 12.7
15.88 19.05 22.22 tions
tions
Drain Pipe ID18 Hose ID18 Hose ID18 Hose
5/8 3/4 7/8

Refrigerant Refrigerant Control Method

Sound 42 46 47 Sound 37 / 34 / 30 41 / 38 / 34 39 / 36 / 33

51.0 85.0 85.0 9.6 9.6 14.5


sion (Outdoor sion (Outdoor
Unit) Unit) 826 x 261 x 261 826 x 261 x 261

Air Filter Type Accessories Included Included Included

Wall Mounted (AR5000) Wall Mounted (AR5000)


Model Code Model Code

CAC
System Mode HP/HR HP/HR HP/HR System Mode HP/HR HP/HR
1.5 2. 2 2.8
7.1 82
Capacity
Capacity

Power Input 14 15 16
Power Input 41 55
Current Input 0.12 0.13 0.13
Current Input 0.31 0.42
Type
Type
Motor 27 27 27
Fan Motor 27 27
4.4 / 4.2 / 3.8 5.4 / 4.7 / 4.0 5.7 / 5.0 / 4.3 Fan
6.35 6.35 6.35
9.52 9.52
1/4 1/4 1/4

12.7 12.7 12.7 tions


tions

FJM
Drain Pipe
Drain Pipe ID18 Hose ID18 Hose ID18 Hose

Refrigerant Control Method Refrigerant Control Method

Sound 28 / 25 / 24 33 / 29 / 25 36 / 31 / 25 Sound

7.9 7.9 8.0 14.5 14.5


sion (Outdoor sion (Outdoor
Unit) 750 x 249 x 246 750 x 249 x 246 750 x 249 x 246 Unit)

Accessories Included Included Included Accessories

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Drain Individual
Controllers Pump Controllers
(Optional) (Optional) (Optional)

MDP-N047SNC0D
MDP-N047SNC1D

2017 Samsung Air Conditioning Solutions 89 90 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

Wall Mounted (Boracay) Wall Mounted (Boracay)


Model Code Model Code

DVMS OUTDOOR UNITS


System Mode HP HP System Mode HP HP

1.5 2. 2 5.6 6.8


Capacity Capacity

Power Input 32 32 Power Input 48 51

Current Input 0.2 0.2 Current Input 0.27 0.28

Type Type

Motor 19 19 Motor 28 28
Fan Fan
14.4 / 12.9 / 11.2 15.7 / 14.1 / 12.9

6.35 6.35 6.35 9.52

DVM S INDOOR UNITS


tions 12.7 12.7 12.7 15.88
tions
Drain Pipe Drain Pipe ID18 Hose ID18 Hose

Refrigerant Control Method Refrigerant Control Method


Sound Sound 39 / 36 / 33 40 / 38 / 35

8.5 8.5 12.5 12.5


sion (Outdoor sion (Outdoor
Unit) 820 x 285 x 277 820 x 285 x 277 Unit)

Wall Mounted (Boracay) Console


Model Code Model Code AM022KNJDEH AM045KNJDEH AM028FNJDEH

CAC
System Mode HP HP HP System Mode HP/HR HP/HR HP/HR

2. 2 4.5 2.8
2.8 3.6 4.5
Capacity
Capacity

Power Input 16 36 30
Power Input 38 42 47
Current Input 0.13 0.3 0.25
Current Input 0.22 0.23 0.27
Type Turbo Fan Turbo Fan Turbo Fan
Type
Fan Motor 37 37 37
Motor 19 19 28
Fan 6.30 / 5.40 / 4.90 11.30 / 9.80 / 8.20 7.00 / 6.00 / 5.00
7.0 / 6.2 / 5.5 8.5 / 7.5 / 6.6 13.9 / 12.4 / 11.2
6.35 6.35 6.35
6.35 6.35 6.35
tions 12.7 12.7 12.7
12.7 12.7 12.7
tions

FJM
Drain Pipe ID18 Hose ID18 Hose ID18 Hose
Drain Pipe ID18 Hose ID18 Hose ID18 Hose Refrigerant Control Method
Refrigerant Control Method Sound 34 / 32 / 30 42 / 39 / 36 38 / 36 / 34
Sound 31 / 29 / 26 36 / 33 / 29 38 / 35 / 33 15.5 16.0 16.0
sion (Outdoor
9.0 9.0 12.5 Unit) 720 x 620 x 199 720 x 620 x 199 720 x 620 x 199
sion (Outdoor
Unit) 820 x 285 x 277 820 x 285 x 277 Accessories

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Wireless Individual Wireless
Controllers Remote Controllers Remote
(Optional) Controller (Optional) Controller
(Default) (Default)

2017 Samsung Air Conditioning Solutions 91 92 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

Console Floor Standing


Model Code AM036FNJDEH AM056FNJDEH Model Code AM036FNFDEH AM056FNFDEH AM071FNFDEH

DVMS OUTDOOR UNITS


System Mode HP/HR HP/HR System Mode HP/HR HP/HR HP/HR

3.6 5.6 3.6 5.6 7.1


Capacity

Capacity
Power Input 35 62
Current Input 0.29 0.49 Power Input 50 110 110

Type Turbo Fan Turbo Fan Current Input 0.24 0.53 0.53

Motor 37 37 Type Sirocco Fan Sirocco Fan Sirocco Fan


Fan Fan
8.50 / 7.50 / 6.50 13.00 / 11.50 / 10.00 10.00 / 8.50 / 6.00 15.50 / 14.00 / 11.00 15.50 / 14.00 / 11.00

6.35 6.35 6.35 9.52 9.52

12.7 12.7 12.7 15.88 15.88

DVM S INDOOR UNITS


tions tions
Drain Pipe ID18 Hose ID18 Hose Drain Pipe ID18 Hose ID18 Hose ID18 Hose

Refrigerant Control Method Refrigerant Control Method


Sound 39 / 37 / 34 43 / 40 / 37 Sound 37 / 32 / 27 40 / 36 / 32 40 / 36 / 32

16.0 16.0 23.0 28.5 28.5


sion (Outdoor sion (Outdoor
Unit) 720 x 620 x 199 720 x 620 x 199 Unit) 945 x 600 x 220

Accessories Accessories

Ceiling/Console PAC
Model Code Model Code AM140JNPDKH AM280JNPDKH/

CAC
System Mode HP/HR HP/HR

14 28
Capacity
Capacity
Power Input
Power Input 190 955
Current Input
Current Input 0.9 4.73

Type Sirocco Fan Sirocco Fan

Fan Motor 154 700


Fan
35.00 / 30.50 / 27.50 70.00 / 60.00 / 50.00

9.52 9.52

tions

FJM
15.88 22.22
tions
Drain Pipe Drain Pipe ID18 Hose
Refrigerant Control Method Refrigerant Control Method
Sound Sound 54 / 47 58 / 54

48.0 115.0
sion (Outdoor sion (Outdoor
Unit) Unit)

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Wireless Individual Wireless
Controllers Remote Controllers Remote
(Optional) Controller (Optional) Controller

TK (Default) TK (Default)
(Turkish) (Turkish) (Turkish) (Turkish)

2017 Samsung Air Conditioning Solutions 93 94 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

DVMS OUTDOOR UNITS


DVM S INDOOR UNITS
CAC
FJM
* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Product Specification in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB
1) Nominal cooling capacities are based on: Indoor temperature : 27o C DB, 19o C WB / Outdoor temperature : 35o C DB
2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB
2) Nominal heating capacities are based on: Indoor temparature : 20o C DB, 15o C WB / Outdoor temperature : 7o C DB, 6o C WB

CONTROL SYSETM
Individual Individual
Controllers Controllers
(Optional) (Optional)

2017 Samsung Air Conditioning Solutions 95 96 www.samsung.com/business


DVM S DVM S

INTRODUCTION
SPECIFICATION SPECIFICATION

ERV Plus ERV Plus

DVMS OUTDOOR UNITS


Model Code AM050FNKDEH Model Code AM100FNKDEH
Features Type Features Type

70 Temperature Exchange 70
Temperature Exchange
70 70
74 74
Effective 60 62
60 62
ciency 66 Effective
Outside Air Processing Cooling 1 (DX Coil / Element) 5.1 (3.6 / 1.5) Outside Air Processing Cooling 1 (DX Coil / Element) 10.5 (7.1 / 3.4)
Capacity Cooling 2 (DX Coil / Element) 6.5 (4.0 / 2.5) Capacity Cooling 2 (DX Coil / Element) 13.2 (8.0 / 5.2)
500 / 500 / 360 1000 / 1000 / 690

DVM S INDOOR UNITS


16.3 / 10.2 / 8.7 15.3 / 9.2 / 7.6
Fan 160 / 100 / 85 Fan 150 / 90 / 75
Motor Type BLDC Motor Type BLDC
Motor Output 180 Motor Output 70
Motor 2 Motor 2
220 510
Power Input High 140 Power Input High 350
Low 90 Low 235
Turbo 1.7 Turbo 3.7
Current Input High 1.0 Current Input High 2.4
Low 0.6 Low 1.6
Option Code 15617152380 Option Code 0156171C2373
6.35 6.35
Piping 12.7 Piping 12.7
Connections Connections

CAC
12.7 12.7
Type R410A Type R410A
Refrigerant Refrigerant
Control Method Control Method
Sound 36 / 32 / 28 Sound 36 / 33 / 31
61.0 90.0
door Unit) door Unit)
200 250
Accessory Air Filter Accessory Air Filter
Type Natural Evaporating Type Type Natural Evaporating Type
1 1
2.7 5.4
Optional Optional
0.02~0.49 0.02~0.49

FJM
Accessory Accessory

Humidity Sensor Option Humidity Sensor Option


Around Unit Around Unit
Ambient Ambient
Condition OA Condition OA
RA RA
* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Optional Individual Optional
Controllers Items Controllers Items
(Optional) (Optional) (Optional) (Optional)

(Humidifier) (Humidifier)

2017 Samsung Air Conditioning Solutions 97 98 www.samsung.com/business


CAC

INTRODUCTION
INDOOR LINE-UP

Cassette

Model

DVMS OUTDOOR UNITS


360 Cassette 4 Way Inverter 4 Way On Off
4.5
Capacity 7.1
(kW)
11.2
14.0

CAC
Duct

Model

INDOOR UNITS

DVM S INDOOR UNITS


Duct S Inverter Duct S On Off
4.5
5.6
7.1
Capacity
9.0
(kW)
11.2
12.8
14.0

Floor Standing

Model

Floor Standing Inverter

CAC
Capacity 11.2
(kW) 14

Console

Model

Big Ceiling On Off

Capacity 10.26
(kW) 15.83

FJM
Ceiling

Model

Big Ceiling
10

CONTROL SYSETM
Capacity 14
(kW)
16

2017 Samsung Air Conditioning Solutions 99 100 www.samsung.com/business


CAC

INTRODUCTION
CAC
Overview
Samsung’s single split unit is smart choice for conserving both running

DVMS OUTDOOR UNITS


costs and energy consumption. This

smart inverter technology. Samsung Ceiling Air Conditioner


(CAC) Single not only offers silent operation but also provides
outstanding cooling and heating performance. provides outstanding
SPECIFICATION
cooling and heating performance.

features such as:

DVM S INDOOR UNITS


Decrease energy consumption by up to 50 percent
with a digital inverter system featuring an economical mode.
Weather severe temperatures dependably and maximize
comfort with wide temperature allowance.

New Energy Label

technologies

to support
businesses in saving costs and the environment. Plus, CAC
Single with its smart technologies fully

consumption labelling for air conditioners


as per EU Directive 2011/626/EU

14kW

which means real cost savings and less energy waste. The EU has established new regulations to drastically cut

in 2013. To further support this initiative, the EU is introducing an improved energy labelling system to provide
consumers a better idea of how much electricity their units consume.

Up to 50 percent less energy use 600

500

After reaching the set temperature, the digital inverter air conditioner Saving

changes its operation mode to economical.


400

300
621.4 Wh/h
302 Wh/h

percent in energy consumption compared to non-inverter (Wh/h) 200

air conditioners.
Multi-unit operation
3.5 + 3.5
Instead of connecting just one indoor unit, users can connect two, three
5.2 + 5.2 or four indoor units with a single outdoor
6.0 + 6.0 5.2 + 5.2
+ 5.2
5.2 + 5.2 3.5 + 3.5
7.1 + 7.1 + 5.2 + 3.5 + 3.5
one cycle within the same mode via one remote controller for up to four
*4 Way & Mini4 Way CST is available.
rooms. This system is ideal for spaces

2017 Samsung Air Conditioning Solutions 101 102 www.samsung.com/business


CAC CAC

INTRODUCTION
SPECIFICATION SPECIFICATION

DVMS OUTDOOR UNITS


Indoor AC024KN4DKH/TC AC036KN4DKH/TC AC048KN4DKH/TC Indoor AC052JN4DEH/AF AC071JN4DEH/AF AC100JN4DEH/AF
Model Code Model Code
Outdoor AC024KXADKH/TC AC036KXADKH/TC AC048KXADKH/TC Outdoor AC052JX4DEH/AF AC071JX4DEH/AF AC100JX4DEH/AF
Cooling [kW] 2.20 / 7.03 / 8.00 2.99 / 10.55 / 11.99 3.49 / 14.07 / 15.50 Cooling [kW] 1.47 / 4.98 / 5.28 2.08 / 7.18 / 7.77 3.22 / 10.26 / 10.57
Capacity Capacity
Cooling [Btu/h] 7,500 / 24,000 / 27,300 10,230 / 36,000 / 40,940 11,940 / 48,000 / 52,880 Cooling [Btu/h] 5,000 / 17,000 / 18,000 7,100 / 24,500 / 26,500 11,000 / 35,000 / 37,000
Power Input Cooling (Min / Std / Max) [kW] 0.35 / 2.52 / 3.95 0.60 / 3.67 / 4.70 0.80 / 5.00 / 6.44 Power Input Cooling (Min / Std / Max) [kW] 0.35 / 1.60 / 1.70 0.38 / 2.45 / 3.00 0.7 / 3.6 / 4.8
Current Input Cooling (Min / Std / Max) [kW] 2.00 / 11.20 / 17.00 3.00 / 16.20 / 20.40 3.70 / 21.70 / 28.00 Current Input Cooling (Min / Std / Max) [kW] 2.20 / 7.20 / 8.00 2.30 / 11.00 / 13.00 4.0 / 16.0 / 21.0
MCA [A] 10.80 20.80 23.70
MCA [A] 21.50 24.50 33.50 Power
Power MFA [A] 12.50 25.00 27.50
MFA [A] 23.65 26.95 36.85

DVM S INDOOR UNITS


EER (Nominal Cooling) [W/W] 3.11 2.93 2.85
EER (Nominal Cooling) [W/W] 2.79 2.87 2.81
6.35 6.35 9.52
6.35 9.52 9.52 Connections 12.7 15.88 15.88
15.88 15.88 15.88 Piping Installation Max. Length [m] 30 30 50
Piping Installation Max. Length [m] 50 50 75 Installation Max. Height [m] 15 15 30
Connections Installation Max. Height [m] 30 30 30 Type R410A R410A R410A
Type R410A R410A R410A Refrigerant
Refrigerant Factory Charging [kg] 1.1 1.3 2.5
Factory Charging [kg] 1.5 3.0 3.5 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50
1,2,220-240,50/60 1,2,220-240,50/60 1,2,220-240,50/60 Type Turbo Turbo Turbo
Type Turbo Fan Turbo Fan Turbo Fan Motor Output [W] 65 65 97
Fan
Fan Motor Output [W] 65 97 97 Air Flow Rate (High / Mid / Low) [CMM] 18.00 / 15.00 / 13.00 21.00 / 18.00 / 16.00 33.0 / 26.0 / 19.0
Air Flow Rate (High / Mid / Low) [CMM] 17.50 / 15.90 / 14.30 31.20 / 25.50 / 19.80 32.40 / 27.10 / 22.80 Drain
Drain Sound Sound Pressure (High / Mid / Low) [dB(A)] 37.0 / 34.0 / 31.0 43.0 / 40.0 / 37.0 43.0 / 38.0 / 33.0
Sound Sound Pressure (High / Mid / Low) [dB(A)] 36.0 / 33.0 / 29.0 44.0 / 39.0 / 33.0 45.0 / 41.0 / 37.0 External DimensionNet Weight [kg] 14.5 14.5 18
External DimensionNet Weight [kg] 21 24 26 (Indoor Unit) Net Dimensions (WxHxD) [mm] 840 x 204 x 840 840 x 204 x 840 840 x 288 x 840

CAC
(Indoor Unit) Net Dimensions (WxHxD) [mm] 947 x 281 x 947 947 x 365 x 947 947 x 365 x 947 Panel model PC4NUSKAN PC4NUSKAN PC4NUSKAN
Panel model PC4NUDMAN PC4NUDMAN PC4NUDMAN Panel Size Panel Net Weight [kg] 5.9 5.9 5.9
Panel Size Panel Net Weight [kg] 3.6 3.6 3.6 Net Dimensions (W×H×D) [mm] 950 x 45 x 950 950 x 45 x 950 950 x 45 x 950
Net Dimensions (W×H×D) [mm] 1,000 x 66 x 1,000 1,000 x 66 x 1,000 1,000 x 66 x 1,000 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50
1,2,220-240,50/60 1,2,220-240,50/60 1,2,220-240,50/60 Type BLDC Rotary BLDC Rotary Twin BLDC Rotary
Type Twin BLDC Rotary Twin BLDC Rotary Twin BLDC Rotary Model UG4T150LNBEQ UG4T200FUAE4 UG8T300LNBJU
Compressor
Output [kW] 4.45 5.92 2.82
Model UG4T200FUAE4 UG8T300FUBJU UG5T450FUEJX
Compressor Oil Type POE POE
Output [kW] 1.78 2.82 4.12
Air Flow Rate (Cooling) [CMM] 40 41 60
Oil Type POE Fan
Air Flow Rate (Cooling) [l/s] 666.67 683.33 1,000.00
Fan Air Flow Rate (Cooling) [CMM] 58.5 78 111
Sound Sound Pressure (Cooling / Heating) [dB(A)] 47.0 / 48.0 49.0 / 51.0 55.0 / 57.0
Sound Sound Pressure (Cooling / Heating) [dB(A)] 49.0 / 51.0 52.0 / 54.0 53.0 / 54.0

FJM
External Dimension
External DimensionNet Weight [kg] 50.5 72.0 90 (Outdoor Unit) Net Weight [kg] 36 45 67
(Outdoor Unit) Net Dimensions (WxHxD) [mm] 880 x 798 x 310 940 x 998 x 330 940 x 1,210 x 330
Operating Cooling [°C] -5~48 -5~48 -5~48
Operating Cooling [°C] -15~50 -15~50 -15~50 Temp. Range Heating [°C] -15~24 -15~24 -15~24

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Panel Individual Panel
Controllers (Optional) Controllers (Optional)
(Optional) (Optional)

MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00 AR-KH00E PC4NUDMAN PC4NBDMAN PC4NUNMAN PC4NBNMAN MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00 AR-KH00E PC4NUSKAN PC4NBSKAN PC4NUSKEN
(360 CST dedicated) (360 CST dedicated)

2017 Samsung Air Conditioning Solutions 103 104 www.samsung.com/business


CAC CAC

INTRODUCTION
SPECIFICATION SPECIFICATION

DVMS OUTDOOR UNITS


Indoor AC140JN4DEH/AF Indoor AC120JN4SEH/AF AC140JN4SEH/AF
Model Code Model Code
Outdoor AC140JX4DGH/AF Outdoor AC120JX4SGH/AF AC140JX4SGH/AF
Cooling [kW] 3.19 / 14.07 / 14.21 Cooling [kW] 11.72 13.19
Capacity Capacity
Cooling [Btu/h] 10,900 / 48,000 / 48,500 Cooling [Btu/h] 40,000 45,000
Power Input Cooling (Min / Std / Max) [kW] 1.30 / 5.20 / 6.30 Power Input Cooling (Min / Std / Max) [kW] 4.25 5.13
Current Input Cooling (Min / Std / Max) [kW] 3.00 / 8.50 / 9.50 Current Input Cooling (Min / Std / Max) [kW] 7.3 8.8
MCA [A] 13.70 MCA [A] 11.00 13.00
Power Power
MFA [A] 15.10 MFA [A] 16.00 20.00

DVM S INDOOR UNITS


EER (Nominal Cooling) [W/W] 2.71
EER (Nominal Cooling) [W/W] 2.76 2.57
9.52
9.52 9.52
15.88
15.88 15.88
Piping Installation Max. Length [m] 50
Connections Piping Installation Max. Length [m] 50 50
Installation Max. Height [m] 30
Connections Installation Max. Height [m] 30 30
Type R410A
Refrigerant Factory Charging [kg] 2.7 2.7
Factory Charging [kg] 2. 2
1,2,220-240,50 1,2,220-240,50 1,2,220-240,50
Type Turbo Type Turbo Fan Turbo Fan
Motor Output [W] 97 Motor Output [W] 97 97
Fan Fan
Air Flow Rate (High / Mid / Low) [CMM] 31.00 / 24.00 / 19.00 Air Flow Rate (High / Mid / Low) [CMM] 31.00 / 28.00 / 25.00 33.00 / 29.00 / 25.00
Drain Air Flow Rate (High / Mid / Low) [l/s] 516.67 / 466.67 / 416.67 550.00 / 483.33 / 466.67
Sound Sound Pressure (High / Mid / Low) [dB(A)] 44.0 / 40.0 / 36.0 Sound Sound Pressure (High / Mid / Low) [dB(A)] 44 / 42 / 40 45 / 43 / 41
External DimensionNet Weight [kg] 18 External DimensionNet Weight [kg] 18 18
(Indoor Unit) Net Dimensions (WxHxD) [mm] 840 x 288 x 840 (Indoor Unit) Net Dimensions (WxHxD) [mm] 840 x 288 x 840 840 x 288 x 840

CAC
Panel model PC4NUSKAN Panel model PC4NUSKAN PC4NUSKAN
Panel Size Panel Net Weight [kg] 5.9 Panel Size Panel Net Weight [kg] 5.8 5.8
Net Dimensions (W×H×D) [mm] 950 x 45 x 950 Net Dimensions (W×H×D) [mm] 950 x 45 x 950 950 x 45 x 950
3,4,380-415,50
3,4,380-415,50 3,4,380-415,50
Type Twin BLDC Rotary
Type Rotary Rotary
Model UG5T450FUFJX
Compressor Model UG3T450BUAHY UG3T530BUAHY
Output [kW] 4.12 Compressor
Output [kW] 4.375 5.185
Oil Type
Oil Type POE POE
Fan Air Flow Rate (Cooling) [CMM] 70.0 Air Flow Rate (Cooling) [CMM] 105 105.0
Fan
Sound Sound Pressure (Cooling / Heating) [dB(A)] 57.0 / 59.0 Air Flow Rate (Cooling) [l/s] 1,750.00 1,750.00

FJM
External DimensionNet Weight [kg] 89 External DimensionNet Weight [kg] 96 97
(Outdoor Unit) Net Dimensions (WxHxD) [mm] 932 x 1,162 x 375 (Outdoor Unit) Net Dimensions (WxHxD) [mm] 932 x 1,162 x 375 932 x 1,162 x 375
Operating Operating Cooling [°C] 21.0 ~ 48.0 21.0 ~ 48.0
Temp. Range Cooling [°C] -5~48 Temp. Range Heating [°C] -5.0 ~ 24.0 -5.0 ~ 24.0

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Panel Individual Panel
Controllers (Optional) Controllers (Optional)
(Optional) (Optional)

MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00 PC4NUSKAN PC4NBSKAN PC4NUSKEN MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00 PC4NUSKAN PC4NBSKAN PC4NUSKEN

2017 Samsung Air Conditioning Solutions 105 106 www.samsung.com/business


CAC CAC

INTRODUCTION
SPECIFICATION SPECIFICATION

DVMS OUTDOOR UNITS


Indoor AC035JNMDEH/AF AC052JNMDEH/AF AC071JNMDEH/AF Indoor AC090JNMDEH/AF AC100JNMDEH/AF AC120JNMDEH/AF
Model Code Model Code
Outdoor AC035JXMDEH/AF AC052JXMDEH/AF AC071JXMDEH/AF Outdoor AC090JXMDEH/AF AC100JXMDEH/AF AC120JXMDGH/AF
Cooling [kW] 1.00 / 3.52 / 4.10 1.47 / 4.98 / 5.28 1.85 / 7.18 / 7.62 Cooling [kW] 2.93 / 8.79 / 9.96 3.02 / 10.26 / 10.57 2.93 / 12.31 / 12.46
Capacity Capacity
Cooling [Btu/h] 3,350 / 12,000 / 14,000 5,000 / 17,000 / 18,000 6,300 / 24,500 / 26,000 Cooling [Btu/h] 10,000 / 30,000 / 34,000 10,300 / 35,000 / 37,000 10,000 / 42,000 / 42,500
Power Input Cooling (Min / Std / Max) [kW] 0.33 / 1.15 / 1.35 0.35 / 1.60 / 1.70 0.47 / 2.50 / 3.23 Power Input Cooling (Min / Std / Max) [kW] 0.9 / 3.37 / 4.6 0.8 / 3.9 / 4.9 1.05 / 4.74 / 5.90
Current Input Cooling (Min / Std / Max) [kW] 2.10 / 5.30 / 6.20 2.20 / 7.30 / 8.00 2.80 / 11.60 / 14.10 Current Input Cooling (Min / Std / Max) [kW] 4.7 / 15.0 / 20.0 4.4 / 18.5 / 21.5 2.10 / 8.00 / 9.20
MCA [A] 10.00 12.70 22.70 MCA [A] 24.70 24.70 14.70
Power Power
MFA [A] 11.00 13.97 25.00 MFA [A] 27.50 27.50 16.20

DVM S INDOOR UNITS


EER (Nominal Cooling) [W/W] 3.06 3.11 2.87 EER (Nominal Cooling) [W/W] 2.61 2.63 2.60
Piping 6.35 6.35 6.35 9.52 9.52 9.52
Connections 9.52 12.7 15.88 15.88 15.88 15.88
Installation Max. Length [m] 20 30 30 Piping Installation Max. Length [m] 50 50 50
Installation Max. Height [m] 15 15 15 Connections Installation Max. Height [m] 30 30 30
Type R410A R410A R410A Type R410A R410A R410A
Refrigerant Refrigerant
Factory Charging [kg] 0.9 1 1.3 Factory Charging [kg] 2.5 2.5 2. 2
1,2,220-240,50 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50
Type Sirocco Fan (BLDC) Sirocco Fan (BLDC) Sirocco Fan (BLDC) Type Sirocco Fan (BLDC) Sirocco Fan (BLDC) Sirocco Fan (BLDC)
Motor Output [W] 153 153 153 Motor Output [W] 153 153 153
Air Flow Rate (High / Mid / Low) [CMM] 9.20 / 7.40 / 5.80 18.70 / 16.50 / 14.00 23.00 / 20.00 / 17.00 Air Flow Rate (High / Mid / Low) [CMM] 29.0 / 25.0 / 22.0 33.0 / 27.0 / 22.0 38.00 / 32.00 / 25.00
Fan Fan
0.00 / 2.50 / 4.00 0.00 / 3.00 / 15.00 0.00 / 3.00 / 15.00 0.0 / 4.0 / 15.0 0.0 / 4.0 / 15.0 0.00 / 5.20 / 15.00
External Static Pressure [Pa] 0.00 / 24.52 / 39.23 0.00 / 29.42 / 147.10 0.00 / 29.42 / 147.10 External Static Pressure [Pa] 0.0 / 39.2 / 147.0 0.0 / 39.2 / 147.0 0.00 / 50.99 / 147.10
Drain Drain

CAC
Sound Sound Pressure (High / Mid / Low) [dB(A)] 32.0 / 29.0 / 26.0 33.0 / 30.0 / 27.0 36.0 / 32.0 / 28.0 Sound Sound Pressure (High / Mid / Low) [dB(A)] 41.0 / 38.0 / 34.0 39.0 / 36.0 / 33.0 42.0 / 38.0 / 34.0
External DimensionNet Weight [kg] 20.0 25.2 25.2 External DimensionNet Weight [kg] 25.0 32.0 32.5
(Indoor Unit) Net Dimensions (WxHxD) [mm] 700 x 199 x 600 850 x 250 x 700 850 x 250 x 700 (Indoor Unit) Net Dimensions (WxHxD) [mm] 850 x 250 x 700 1200 x 250 x 700 1200 x 250 x 700
1,2,220-240,50 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50 3,4,380-415,50
Type BLDC Rotary BLDC Rotary BLDC Rotary Type BLDC Rotary BLDC Rotary Twin BLDC Rotary
Model UG9A090FUAER UG4T150LNBEQ UG4T200FUAE4 Model UG8T300LNBJU UG8T300LNBJU UG5T450FUFJX
Compressor Compressor
Output [kW] 2.77 4.45 5.92 Output [kW] - - 4.12
Oil Type POE POE POE Oil Type
Fan Air Flow Rate (Cooling) [CMM] 37 40 41 Fan Air Flow Rate (Cooling) [CMM] 60 60 70
Sound Sound Pressure (Cooling / Heating) [dB(A)] 47.0 / 48.0 47.0 / 48.0 49.0 / 51.0 Sound Sound Pressure (Cooling / Heating) [dB(A)] 54.0 / 56.0 55.0 / 57.0 57.0 / 58.0

FJM
External DimensionNet Weight [kg] 29.5 36 45 External DimensionNet Weight [kg] 67 67 89
(Outdoor Unit) Net Dimensions (WxHxD) [mm] 720 x 548 x 265 790 x 548 x 285 880 x 638 x 310 (Outdoor Unit) Net Dimensions (WxHxD) [mm] 880 x 967 x 320 880 x 967 x 320 932 x 1,162 x 375
Operating Operating
Temp. Range Cooling [°C] -5~48 -5~48 -5~48 Temp. Range Cooling [°C] -5~48 -5~48 -5~48

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Drain Individual Drain
Controllers Pump Controllers Pump
(Optional) (Optional) (Optional) (Optional)

MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00 MDP-G075SP MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00 MDP-G075SP
(External Type) (External Type)

2017 Samsung Air Conditioning Solutions 107 108 www.samsung.com/business


CAC CAC

INTRODUCTION
SPECIFICATION SPECIFICATION

DVMS OUTDOOR UNITS


Indoor AC140JNMDEH/AF AC160JNMDEH/AF Indoor AC120JNMSEH/AF AC140JNMSEH/AF
Model Code Model Code
Outdoor AC140JXMDGH/AF AC160JXMDGH/AF Outdoor AC120JXMSGH/AF AC140JXMSGH/AF
Cooling [kW] 3.19 / 13.77 / 13.92 3.22 / 15.83 / 16.12 Cooling [kW] 11.43 12.9
Capacity Capacity
Cooling [Btu/h] 10,900 / 47,000 / 47,500 00/ 54,000 / 55,000 Cooling [Btu/h] 39,000 44,000
Power Input Cooling (Min / Std / Max) [kW] 1.30 / 5.30 / 6.50 1.08 / 6 .07 / 6.35 Power Input Cooling (Min / Std / Max) [kW] 4.4 5.43
Current Input Cooling (Min / Std / Max) [kW] 2.50 / 9.00 / 10.00 2.20/9.70 / 10.00 Current Input Cooling (Min / Std / Max) [kW] 7.5 9.2
MCA [A] 14.70 15.50 MCA [A] 12.00 14.00
Power Power
MFA [A] 16.20 17.10

DVM S INDOOR UNITS


MFA [A] 16.00 20.00
EER (Nominal Cooling) [W/W] 2.60 2.61 EER (Nominal Cooling) [W/W] 2.60 2.38
9.52 9.52 9.52 9.52
15.88 19.05 15.88 15.88
Piping Installation Max. Length [m] 50 50
Piping Installation Max. Length [m] 50 50
Connections Installation Max. Height [m] 30 30 Connections Installation Max. Height [m] 30 30
Type R410A R410A
Refrigerant Factory Charging [kg] 2.6 2.7
Factory Charging [kg] 2. 2 3.5
1,2,220-240,50 1,2,220-240,50
1,2,220-240,50 1,2,220-240,50
Type Sirocco Fan Sirocco Fan
Type Sirocco Fan (BLDC) Sirocco Fan (BLDC)
Motor Output [W] 153 153
Motor Output [W] 153 244
Air Flow Rate (High / Mid / Low) [CMM] 38.00 / 32.00 / 25.00 43.00 / 35.00 / 27.00
Air Flow Rate (High / Mid / Low) [CMM] 42.00 / 34.00 / 27.00 49.00 / 43.00 / 37.00 Fan
Fan 0.00 / 5.20 / 15.00 0.00 / 5.20 / 15.00
0.00 / 5.20 / 15.00 0.00 / 5.20 / 15.00
External Static Pressure [Pa] 0.00 / 50.96 / 147.00 0.00 / 50.96 / 147.00
External Static Pressure [Pa] 0.00 / 50.99 / 147.10 0.00 / 50.99 / 147.10
Drain
Drain

CAC
Sound Sound Pressure (High / Mid / Low) [dB(A)] 43.0 / 39.0 / 34.0 44.0 / 40.0 / 35.0 Sound Sound Pressure (High / Mid / Low) [dB(A)] 42 / 38 / 34 43 / 39 / 34
External DimensionNet Weight [kg] 32.5 38.0 External DimensionNet Weight [kg] 32.5 32.5
(Indoor Unit) (Indoor Unit) Net Dimensions (WxHxD) [mm] 1,200 x 250 x 700 1,200 x 250 x 700
Net Dimensions (WxHxD) [mm] 1200 x 250 x 700 1300 x 300 x 700
3,4,380-415,50 3,4,380-415,50 3,4,380-415,50 3,4,380-415,50
Type Twin BLDC Rotary Twin BLDC Rotary Type Rotary Rotary
Model UG5T450FUFJX UG5T450FUFJX Model UG3T450BUAHY UG3T530BUAHY
Compressor Compressor
Output [kW] 4.12 4.12 Output [kW] 4.375 5.185
Oil Type Oil Type POE POE
Fan Air Flow Rate (Cooling) [CMM] 70 70 Fan Air Flow Rate (Cooling) [CMM] 105 105
Sound Sound Pressure (Cooling / Heating) [dB(A)] 57.0 / 59.0 57.0 / 59.0 Sound Sound Pressure (Cooling / Heating) [dB(A)] 55 / 56 55 / 56
External DimensionNet Weight [kg] 96 97

FJM
External Dimension et Weight [kg]
N 89 97
(Outdoor Unit) Net Dimensions (WxHxD) [mm] 932 x 1,162 x 375 932 x 1,162 x 375 (Outdoor Unit) Net Dimensions (WxHxD) [mm] 932 x 1,162 x 375 932 x 1,162 x 375
Operating Operating Cooling [°C] 21.0 ~ 48.0 21.0 ~ 48.0
Temp. Range Cooling [°C] -5~48 -5~48 Temp. Range Heating [°C] -5.0 ~ 24.0 -5.0 ~ 24.0

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Drain Individual Drain
Controllers Pump Controllers Pump
(Optional) (Optional) (Optional) (Optional)

MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00 MDP-G075SP MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00 MDP-G075SP
(External Type) (External Type)

2017 Samsung Air Conditioning Solutions 109 110 www.samsung.com/business


CAC CAC

INTRODUCTION
SPECIFICATION SPECIFICATION

DVMS OUTDOOR UNITS


Indoor Indoor AC140JNCDEH/EU AC160JNCDEH/EU
Model Code
Outdoor Model Code
Outdoor AC140JXADEH/EU AC160JXADGH/EU
System Mode Cooling Only Cooling Only
System Mode Heat Pump Heat Pump
Cooling [kW] 10.26 15.83
Capacity Cooling [kW] 4.30 / 14.00 / 15.40 4.30 / 15.00 / 17.30
Cooling [Btu/h] 35,000 54,000 Capacity
Cooling [Btu/h] 14,700 / 47,800 / 52,500 14,700 / 51,200 / 59,000
Power Input Cooling (Min / Std / Max) [kW] 3.38 5.22
Power Input 0.90 / 5.28 / 6.40
Current Input Cooling (Min / Std / Max) [kW] 16 24
Current Input 1.70 / 8.20 / 9.80

DVM S INDOOR UNITS


MCA [A] 26.70 36.70
Power MCA [A] 26.70 14.70
MFA [A] 30.00 40.50 Power
MFA [A] 30.00 16.20
EER (Nominal Cooling) [W/W] 3.04 3.03
EER (Nominal Cooling) [W/W] 3.01 2.84
Liquid Pipe [Ø, mm] 9.52 9.52
Liquid Pipe [Ø, mm] 9.52 9.52
Piping Gas Pipe [Ø, mm] 15.88 15.88 Gas Pipe [Ø, mm] 15.88 15.88
Connections Installation Max. Length [m] 50 75 Piping Installation Max. Length [m] 75 75
Installation Max. Height [m] 30 30 Connections Installation Max. Height [m] 30 30
1,2,220-240,50/60 1,2,220-240,50/60
1,2,220-240,50
Type Sirocco Sirocco Type Sirroco Sirroco
Fan Motor Output [W] 153 244 Motor Output [W] 244 37.00 / 31.00 / 26.00
Air Flow Rate (High / Mid / Low) [CFM] 918.22 / 812.27 / 671.00 1,306.69 / 1,094.80 / 918.22 Fan
-
Drain Drain Pipe [Ø, mm] Drain Drain Pipe [Ø, mm]

CAC
Sound Sound Pressure (High / Mid / Low) [dB(A)] 48.0 / 44.0 / 40.0 51.0 / 47.0 / 43.0 Sound -
External DimensionNet Weight [kg] 33.0 42
External DimensionNet Weight [kg] 42.0 -
(Indoor Unit) Net Dimensions (WxHxD) [mm] 1,350 x 235 x 675 1,650 x 235 x 675 (Indoor Unit) -
1,2,220-240,50/60 1,2,220-240,60 1,2,220-240,50
Type Twin BLDC Rotary Twin BLDC Rotary Type Twin BLDC Rotary Twin BLDC Rotary
Compressor
Output [kW] 2.82 4.01 Compressor Output [kW] 4.12 4.12
Oil Type Oil Type POE
Fan Air Flow Rate (Cooling) [CFM] 50 110.0 Fan Air Flow Rate (Cooling) [CMM] 100 115
Sound Sound Pressure (Cooling / Heating) [dB(A)] 52 55 Sound Sound Pressure (Cooling / Heating) [dB(A)] 56.0 / 58.0
External DimensionNet Weight [kg] 62 90 External DimensionNet Weight [kg] 88.0 96.0

FJM
(Outdoor Unit) Net Dimensions (WxHxD) [mm] 880 x 967 x 320 940 x 1,420 x 330 (Outdoor Unit) 940 x 1420 x 330
Operating Operating
Cooling [°C] -15~50 -15~50 Cooling [°C] -15~50 -15~50
Temp. Range Temp. Range

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
Individual Individual
Controllers Controllers
(Optional) (Optional)

MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00 MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00

2017 Samsung Air Conditioning Solutions 111 112 www.samsung.com/business


FJM

INTRODUCTION
OUTDOOR / INDOOR LINE-UP

FJM 5kW 6kW

DVMS OUTDOOR UNITS


SPECIFICATION
7.8 kW 10kW

DVM S INDOOR UNITS


Duct

Model

LSP (Slim)
2.6
Capacity
3.5
(kW)

CAC
5.2

Wall Mounted

Model

FJM
2.0
2.5
Capacity
3.5
(kW)
5.0
6.8
* Concerning exact capacity for each model above, please refer to the specification sheet in detail.

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 113 114 www.samsung.com/business
FJM FJM

INTRODUCTION
Samsung Free Joint Multi adopts the innovative Twin Brushless Direct Current (BLDC) rotary compressor for

DVMS OUTDOOR UNITS


70 percent compared to the conventional Single BLDC compressor, offering smoother, more consistent operation.
High-quality moving parts such as robust bearings, as well as premium matching rollers and vanes, produce a
high degree of stability and durability.

optimized cooling system for residences and smaller buildings with limited installation space. Its lightweight,
small-scale build and one-button auto-addressing enable easy and low-cost installation, while its uniquely quiet With its superior insulation and low vibration, FJM offers a comforting environment undisturbed by bothersome
noise levels typical of standard air conditioning systems. Residents can enjoy a more restful night and employees
can increase focus levels with less disturbance.

DVM S INDOOR UNITS


such as:

High performance. Samsung Free Joint Multi adopts the innovative Twin Brushless Direct Current (BLDC) rotary compressor for

Easy installation. Ease installation and minimize effort with a small footprint 70 percent compared to the conventional Single BLDC compressor, offering smoother, more consistent operation.
and one-button auto-addressing. High-quality moving parts such as robust bearings, as well as premium matching rollers and vanes, produce a
Low noise levels. Enjoy a more peaceful home or work environment with quiet high degree of stability and durability.
operation, thanks to double-layered sound insulation.

Featuring a suite of energy-optimizing technologies, Samsung FJM delivers top-

Quiet Operation

CAC
Plus, CAC Single with its smart technologies fully complies with new European
Double-layered sound insulation material fully covers the compressor to absorb and
minimize the noise for quieter operation, making it more discreet despite its high-quality
performance.

design and premium moving parts, the FJM air conditioning system delivers balanced performance for high

FJM
building exterior clean
esign
ensit and neat.
tr ty

Samsung Free Joint Multi adopts the innovative Twin Brushless Extremely Low Vibration
Direct Current (BLDC) rotary compressor for Tw s
s
New Sine Wave Controller Conventional Square Wave Controller
70 percent compared to Sine Wave Controller
the conventional Single BLDC compressor, offering smoother, Highly Stable Moving Parts
Current
All Samsung FJM models have adopted a newly developed Sine
more consistent operation. High-quality moving parts such as

CONTROL SYSETM
Wave

Wave Controller. Smoother current waves result in a soft acoustic


robust bearings, as well as premium matching rollers and vanes,
quality and overall noise reduction.
produce a high degree of stability and durability. t
Torque
Ripple

2017 Samsung Air Conditioning Solutions 115 116 www.samsung.com/business


FJM FJM

INTRODUCTION
SPECIFICATION SPECIFICATION

DVMS OUTDOOR UNITS


FJM 2 TICKS FJM 2 TICKS
Model Code Outdoor AJ18FCJ3EC AJ21FCJ3EC AJ27HCJ4EC Model Code Outdoor AJ34HCJ5EC
Cooling [kW] 5 6 7.8 Cooling [kW] 10
Capacity Capacity
Cooling [Btu/h] 17,100 20,500 26,600 Cooling [Btu/h] 34,100

Power Input Cooling (Min / Std / Max) [kW] 1.42 1.78 2.3 Power Input Cooling (Min / Std / Max) [kW] 2.95

Current Input Cooling (Min / Std / Max) [kW] 6.5 8.1 10.5 Current Input Cooling (Min / Std / Max) [kW] 13.5

DVM S INDOOR UNITS


MCA [A] 12.00 13.70 17.20 MCA [A] 26.62
Power Power
MFA [A] 13.75 15.63 19.38 MFA [A] 29.69

EER (Nominal Cooling) [W/W] 3.52 3.37 3.39 EER (Nominal Cooling) [W/W] 3.39

NEA Ticks 2 Ticks 2 Ticks 2 Ticks NEA Ticks 2 Ticks

Liquid Pipe [Ø, mm] 6.35 6.35 6.35 Liquid Pipe [Ø, mm] 6.35

Gas Pipe [Ø, mm] 9.52 9.52 9.52 Gas Pipe [Ø, mm] 9.52

Installation Max. Length [m] 25 25 25 Installation Max. Length [m] 25


Piping Piping
Connections Connections
Installation Max. Height [m] 15 15 15 Installation Max. Height [m] 15

Type R410A R410A R410A Type R410A


Refrigerant Refrigerant
Factory Charging [kg] 2 2 2.4 Factory Charging [kg] 3

CAC
1,2,220-240,50 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50

Type Twin BLDC Rotary Twin BLDC Rotary Twin BLDC Rotary Type Twin BLDC Rotary

Model UG4T200FUAE4 UG4T200FUAE4 UG4T200FUAE4 Model UG8T300FUBJU


Compressor Compressor
Output [kW] 5.92 5.92 5.92 Output [kW] 9.17

Oil Type POE POE POE Oil Type POE

Fan Air Flow Rate (Cooling) [CMM] 35.74 41.37 56.79 Fan Air Flow Rate (Cooling) [CMM] 70.58

Sound Sound Pressure (Cooling / Heating) [dB(A)] 44 47 50 Sound Sound Pressure (Cooling / Heating) [dB(A)] 54

FJM
Net Weight [kg] 47.5 47.5 58 Net Weight [kg] 71.6
External Dimension External Dimension
(Outdoor Unit) (Outdoor Unit)
Net Dimensions (WxHxD) [mm] 880 x 638 x 310 880 x 638 x 310 880 x 798 x 310 Net Dimensions (WxHxD) [mm] 940 x 998 x 330
Operating Operating
Temp. Range Cooling [°C] 10.0 ~ 46.0 10.0 ~ 46.0 10.0 ~ 46.0 Cooling [°C] 10.0 ~ 46.0
Temp. Range

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product. * Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB * Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 117 118 www.samsung.com/business
FJM

INTRODUCTION
SPECIFICATION

CONTROL SYSTEM

DVMS OUTDOOR UNITS


FJM 2 TICKS
Model Code Outdoor AJ09FBADEC AJ12FBADEC AJ18FBADEC AJ24FBADEC
Wall Mounted Wall Mounted Wall Mounted Wall Mounted
Features Type (AR5000) (AR5000) (AR5000) (AR5000)
1,2,220-240,50 1,2,220-240,50 1,2,220-240,50 1,2,220-240,50

Cooling [kW] 2.5 3.5 5 6.8


Capacity
Cooling [Btu/h] 8,500 11,900 17,100 23,200

Type

Fan Motor Output [W] 20 20 27 27

Air Flow Rate (High / Mid / Low) [CMM] 7.74 / 7.07 / 6.40 9.08 / 8.08 / 7.07 17.29 / 14.89 / 12.49 16.69 / 14.89 / 13.09

DVM S INDOOR UNITS


Drain Drain Pipe [Ø, mm] ID18 HOSE ID18 HOSE ID18 HOSE ID18 HOSE

Sound Pressure (High/Mid/Low) [dB(A)] 31 / 27 / 19 30 / 19 41 / 33 / 23 43 / 37 / 25

Net Weight [kg] 9.5 9.5 13 13


External
Dimension
Net Dimension (WxHxD) [mm] 826 x 261 x 261 826 x 261 x 261 1,065 x 301 x 294 1,065 x 301 x 294

Individual Wireless
Controllers Remote
(Optional) Controller
(Default)
MWR-WE10N MWR-SH10N MWR-SH00N MR-EH00

FJM 2 TICKS

CAC
Model Code Outdoor AJ12FBMDEC AJ18FBMDEC
Features Type Duct S Duct S

1,2,220-240,50 1,2,220-240,50

Cooling [kW] 3.5 5


Capacity
Cooling [Btu/h] 11,900 17,100

Type Sirocco fan Sirocco fan

Fan Motor Output [W] 153 153

Air Flow Rate (High / Mid / Low) [CMM] 12.00 / 9.50 / 8.00 21.00 / 18.00 / 15.00

FJM
Drain Drain Pipe [Ø, mm]

Sound Pressure (High/Mid/Low) [dB(A)] 32 / 29 / 26 35 / 32 / 29

Net Weight [kg] 25 25


External
Dimension
Net Dimension (WxHxD) [mm] 850 x 250 x 700 850 x 250 x 700

* Product Specifications in the Publication can be changed without a prior notice. Because there is always an ongoing improvement on our product.
* Nominal cooling capacities are based on; Indoor temperature : 27°C DB, 19°C WB / Outdoor temperature : 35°C DB

Individual Drain
Controllers Pump
(Optional) (Optional)

MWR-WE10 MWR-WH00 MWR-SH00 MR-EH00 AR-MRK-A10N MDP-G075SP


MWR-WH02 (External Type)

2017 Samsung Air Conditioning Solutions 119 120 www.samsung.com/business


CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
Manage and monitor single or multiple
S-NET 3 units conveniently from a central, remote location
This integrated software connects to the internet to control the

DVMS OUTDOOR UNITS


system air conditioners through DMS from a single computer.

DMS 2.5
DMS 2.5 is an internet-based management device that stores and
manages all the data relevant to the air conditioners.

DVM S INDOOR UNITS


Samsung Control System offers convenient, centralised control of individual indoor units or entire groups of
On / Off Controller multiple units. Using a variety of controls, users can centrally manage and control multiple functions on their air
The On/Off controller controls the air conditioners individually or in conditioning units.
groups supporting many other functions.

Integrated Management

CAC
Samsung’s Integrated Management System provides an easy way to manage a large number of air conditioning
units at once. This integrated system helps users control, monitor, manage and maintain every little detail of their
air conditioning needs. Supporting convenient and optimised management, Samsung’s Integrated Management
System is an ideal solution for managing large and middle-sized buildings with many indoor and outdoor units.
Wired R/C, Wireless R/C
The individual remote controllers are used to control single indoor
units more conveniently. System Controller
Samsung’s control system offers various control options for indoor units. Users can control multiple units
individually or simultaneously in groups to optimise convenience.

FJM
Building Management
Touch Centralized Controller Samsung Building Management System (BMS) makes it possible to control and monitor the air conditioning
This 7" Touch Screen CRC controller is the optimised management network using the remote control and monitoring function. Optimum control keeps the air conditioning system
solution for mid-size site.

CONTROL SYSETM
Applications

2017 Samsung Air Conditioning Solutions 121 122 www.samsung.com/business


CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
S-NET 3
S-NET 3 manages a group of buildings through Data Management Servers (DMS 2.5) that individually manage

DVMS OUTDOOR UNITS


DVM S INDOOR UNITS
Fully integrated PC management software

Up to 16 DMS 2.5 connection through the Ethernet

Centralized management of up to 4,096 indoor units including ERV, ERV Plus and AHU

Scheduled / Zone control

Error/Operation history management

CAC
Power distribution management and analysis

DMS 2.5

FJM
CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 123 124 www.samsung.com/business
CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
Control and Monitoring DMS 2.5
Users can control and monitor up to 4,096 indoor units, including ERV, ERV The New Data Management Server (DMS) 2.5 can manage a variety of different air conditioning units, and the

DVMS OUTDOOR UNITS


PLUS and AHU. Wireless and wired remote control restrictions provide newly upgraded functions can automatically manage the air conditioning system for users.
greater visibility on operations. The range of control includes temperature
limit setting, operation mode lock and multiple/all indoor unit selection. Built-in web server for PC-independent management and remote access control
In addition, an icon-based indoor unit display mode enables easier and
Multiple upper-level control access (S-NET 2, Web-client)
more intuitive usability.
Centralized management of up to 256 indoor units including ERV, ERV PLUS and AHU
Power Distribution Management
User editable control logic
Users can ensure optimal power usage with a data query for power
distribution and operation times. Administrators can then generate and Accessible level management
print power distribution reports for a complete survey on the operations. Dynamic security management

DVM S INDOOR UNITS


different electricity rates and a group setting for the power distribution Operation & error history management
summary. Weekly/Daily schedule control

Schedule Control Power distribution function

S-NET 3 provides easy-to-read graphical schedule settings, enabling Current time management even during power failure (for 24 hours)

Data storage in non-volatile memory and SD memory

Emergency stop function with simple contact interface

History Management

CAC
S-NET 3 offers error and event history management, as well as report
generation and printing, so users can readily identify and resolve issues.
There is also operation history management for indoor units.

Zone management DMS 2.5


With S-NET 3, users can customize the management structure regardless PIM Watt Hour Meter
of the installation structure. They can also create and edit control zones

FJM
and manage the tree structure for the control zones.

Cycle monitoring
S-NET 3 enables users to monitor outdoor / indoor unit cycle data. (The

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 125 126 www.samsung.com/business
CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
Monitoring of Air-Conditioning Operation Accessible Level Management
DMS 2.5 enables administrator to specify the scope of unit control and monitoring by each users.

DVMS OUTDOOR UNITS


checked in the control room. This helps to reduce service lead time and keep the units up and running.

DVM S INDOOR UNITS


Dynamic User Security Management
General users, managers, and administrators can be registered separately by ID and password. Administrators
(utility managers) have the authority to set access levels for DMS 2.5 functions by users.

Easy Control & Monitoring Admin Manager User


Functions
Users can control and monitor up to 256 indoor units, including ERV, ERV PLUS, AHU, DVM CHILLER and FCU Kit, Access All Changeable
via the Internet. The control functions include on/ off operation mode, and fan speed and temperature settings.
Control/Monitoring O O O

Zone management O O X

Schedule O O O

CAC
Power distribution O O X

O X X

Control for Unoccupied Room


DMS 2.5 offers useful function for accommodations. Using this function, manager can keep the room temperature
when guest goes out for a while. And manager can pre-cool or pre-heat the room temperature before guest
Indoor Unit Operation History Management enters the room.
DMS 2.5 features operation history for indoor units, which records data for up to 6 months. The operation history

FJM
stores the following parameters:

CONTROL SYSETM
Storage Period - Up to 6 months

2017 Samsung Air Conditioning Solutions 127 128 www.samsung.com/business


CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
Enhanced Graphical Display Rapid & Easy Service Response

DVMS OUTDOOR UNITS


based, colour-coded unit control makes it easy to recognise indoor unit status, while a handy, stylish controller at your private email account in the event of malfunction.
makes management even more convenient.

Color indication and icons make it


easy to recognize indoor unit status

Malfunction
User-friendly icon-based unit control
E-mail

DVM S INDOOR UNITS


Remote Service

Convenient &
stylish controller

User Editable Control Logic

CAC
Powerful Data Backup used and reduced for various operation conditions.

Critical data is safely stored on the DMS 2.5 SD memory card, including:

Room

Outdoor
WINTER SUMMER

FJM
Logic Outdoor temp < Room temp Room temp < Outdoor temp Outdoor temp < 10 Outdoor temp > 25
Data Back-up
Control Turn ON ERV (Cool air Intake Turn ON Air Conditioner Heating mode Cooling mode
UP)

EHP / ERV / AHU Arithmetic Equation EHP / ERV / AHU


Parameters AND Function Parameters change
OR
Temperature, Power, Mode...... <, >, =, =>, =<, Average Setting temp, Power, Mode, Fan speed......

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 129 130 www.samsung.com/business
CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
CENTRALIZED CONTROL
Useful History Management Operation History
Samsung offers a host of interface modules designed to support superior control of indoor and outdoor units.
DMS 2.5 records indoor unit operation and error occurrence history. 2. Daily accumulated operation on time

DVMS OUTDOOR UNITS


Recorded history makes it convenient to analyse air-conditioner
operation and perform unit maintenance. Error History
1. Error occurred unit name
2. Error details
3. Error occurrence/clear time
4. Error state (solved / unsolved )

Smart Central Management

DVM S INDOOR UNITS


DMS 2.5, the Control and Monitoring Zone edition, offers smart
centralised zone management. The restrictions on wireless and wired B Zone
remote controller provide better visibility on operations. It can also
A Zone
manage temperature limit setting and operation mode restriction.

A Zone Cooling only/No remote controller/ Minimum setting temperature in cooling is 20OC MCM-A202DN MCMA300N

B Zone Cooling only/Remote controller use

Touch Centralized Controller | MCM-A300N


Power Distribution System Indoor Unit Operation State

CAC
DMS 2.5 can connect power distribution system to 256 5th Floor
140kWh
indoor units to provide data query for watt-hour, usage time 4th Floor Energy saving control
610kWh
and usage ratio. One year power distribution data is saved
3rd Floor
460kWh

DMS 2.5 also provides current actual power consumption 2nd Floor
360kWh
1. Operation Data Accumulation
monitoring, as well as current type electricity meter support and Power Distribution 1st Floor
180kWh
(CT ratio input).
2. Data Extract
- Excel Format

FJM
Easy and Intuitive UI
Watt-hour Meter Interface Module
operation condition
2.5 power distribution, displaying power consumption for each watt-
hour meter. It connects up to eight watt-hour meters and features a
pulse interface for each meter.

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 131 132 www.samsung.com/business
CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
On/Off Controller
Control and Monitoring
MCM – A300N

DVMS OUTDOOR UNITS


color and icon

* MCM-A202DN is compatible with MCM-A202A and MCM-A202B

DVM S INDOOR UNITS


Zone Management for multiple units

MIM-N01
Communication interface module between outdoor units and the upper
recognize each zone
level controller which has different communication type

CAC
Schedule Control

including: temperature setting, mode and fan speed

MIM-N10
Communication interface module between ERV and the upper level

FJM
CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 133 134 www.samsung.com/business
CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
Wi-Fi Kit INDIVIDUAL CONTROL
MIM-H03N Samsung's individual control system has a variety of wired and wireless controllers that enable you to easily

DVMS OUTDOOR UNITS


control your air conditioners. You can choose the one that best suits your air conditioning environment.

Wireless Remote Controller MR-EH00

(This function is available in certain outdoor unit model)

DVM S INDOOR UNITS


Premium Wireless Dial Remote Controller AR-KH00E
Wi-Fi Kit Connection
Schedule Control

System F1/F2/F3 Wireless (Wi-Fi)


Wired Remote Controller MWR-WE11N

CAC
air conditioner
Router*

Samsung
Smart
Wireless AP Wired(LAN)
home
server

* Mobile app wirelessly connects to Wi-Fi kit through the wireless AP.
If your mobile phone is not connected to the wireless AP, it connects through Samsung Smart Home Server

Inside of building

FJM
* Connection through Samsung Smart Home Server

Outside of building

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 135 136 www.samsung.com/business
CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
WPremium LED Touch Screen BUILDING MANAGEMENT MODULE
Wired Remote Controller MWR-SH10N Samsung Building Management System (BMS) provides various control functions for integrated management of

DVMS OUTDOOR UNITS


environment.

BACnet Gateway
With the BMS control and monitoring function, BACnet gateway makes it easy to control the air conditioning
network in various ways. BACnet gateway can control up to 256 indoor units, used in combination with S-NET 3.

DVM S INDOOR UNITS


Control Monitoring
ERV Wired Controller MWR-VH12N On/Off control Filter alarm reset On/Off control Thermo On/Off
Operation mode User control restriction Operation mode Power distribution
Temperature setting Operation mode lock Set/Room temperature Operation mode lock
Fan speed/direction Set temperature limit Fan speed/direction Set temperature limit
ERV operation mode Emergency stop ERV operation mode In/Out contact state
ERV fan speed Output contact control ERV fan speed Emergency stop
Filter alarm Error code
User control restriction

CAC
Connection

Wireless Signal Receiver MWR-A10N


RS485

Ethemet

FJM
External Room Sensor MWR-TA

BACnet BMS

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 137 138 www.samsung.com/business
CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
LonWorks Gateway MIM-B18N (DMS-Lnet) Watt-hour Meter Interface Module MIM-B16N PIM (Pulse Input Module)
LonWorks gateway is an interface for Lon-Connection to LonWorks management system, providing you with a

DVMS OUTDOOR UNITS


consumption for each watt-hour meter.
in combination with S-NET 3.

DVM S INDOOR UNITS


Control Monitoring

Connection
Connection

CAC
Supports Max.8
PIM
RS485
FTT-10A

FJM
Supports Max.8
Indoor Unit
Outdoor Unit

LonWork BMS

CONTROL SYSETM
2017 Samsung Air Conditioning Solutions 139 140 www.samsung.com/business
CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
Remotely monitor operations 24/7 for the ultimate in convenient control Group Management Remote Fault Detection
Zen Manager enables seamless remote control and 24-hour monitoring via the Internet. It offers users reports

DVMS OUTDOOR UNITS


RMS MST-R5D

DVM S INDOOR UNITS


Report User Friendly Widget
Air conditioning system

CAC
ZenManager Mobile RM center
Mobile App Data Analysis

FJM
RM center RMS Web

CONTROL SYSETM
RMS Server

RMS Mobile Web


DMS2

2017 Samsung Air Conditioning Solutions 141 142 www.samsung.com/business


CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
GUESTROOM MANAGEMENT MODULE NEW DVM-PRO
Guest Room Management system saves you energy and money on cooling an unoccupied room. The air Samsung’s new DVM-Pro is an advanced design and automation tool that can be used in AutoCAD-based

DVMS OUTDOOR UNITS


conditioner is activated when Key-Tag is in place and turns off when Key-Tag is removed. CAD mode or Windows®-based Sales mode. This new program can help you in selecting the right type of air
conditioner equipment so that you can easily and precisely design your air conditioning system.
External Contact Interface Module MIM-B14

Samsung Guestroom Management System saves users the energy and money wasted on cooling an unoccupied
Sales Mode
room. The air conditioner is activated when the Key-Tag is in place and turns off when the Key-Tag is removed. The Sales Mode enables users to customise their air conditioning system by selecting the following categories:

DVM S INDOOR UNITS


Download! http://pvi.samsung.com Download Center Software NEW DVM-Pro
(Wall-mounted Type Indoor Units : Only models that include EEV support state output function.)
* E-mail : dvm.pro@samsung.com

Error

CAC
Key-Tag Window Open Sensor Malfunction Alarm Extemal Device Control

CAD mode
The CAD mode provides quick, easy, precise design, enabling users to customize their air conditioning system

FJM
using AutoCAD add-on software. (AutoCAD is not included in New DVM-PRO.) This mode features:

CONTROL SYSETM
* Contact to Samsung HQ or
Distributors for NEW DVM-Pro!

2017 Samsung Air Conditioning Solutions 143 144 www.samsung.com/business


CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
Line-up

Optimize performance and energy savings with seamless AHU connectivity DVM, CAC
MODEL
CLASSIFICATION PRODUCT IMAGE APPLICATION
(New Communication
Samsung AHU Kit allows DVM S outdoor units to connect to air handling units (AHUs), which results in energy Protocol)

DVMS OUTDOOR UNITS


MST-P3P MST-P3P
S-NET 3
MST-S3W Cassette & Ceiling
Controller
Features includes: Integrated DMS 2.0 MIM-D00A Cassette & Ceiling
Management
System DMS 2.5 MIM-D01AN Including(DVM chiller, FCU kit)

PIM
MIM-B16N MIM-B16
(Electricity meter)
Interface Module
SIM
MIM-B12N
(RS485 Comm. Electricity meter)
Building
ZenManager MST-R5D MST-R5D Mobile
Management
Building LonWorks Gateway(New) MIM-B18N MIM-B18 Including(DVM chiller, FCU kit)
Management Gateway
Module BACnet Gateway(New) MIM-B17N MIM-B17 Including(DVM chiller, FCU kit)
Interface
LonWorks Gateway Interface - MIM-B07
Module

DVM S INDOOR UNITS


Centralized Touch Controller MCM-A300N -

Function Controller MCM-A100 MCM-A100 Cassette & Ceiling


Controller
On/Off Controller MCM-A202DN MCM-A202D Cassette & Ceiling

Operation Mode Selection Switch MCM-C200 -

Centralized MIM-B14 MIM-B14


Control
MTFC
System MCM-C210N
(Multi Tenant Function Controller)
Outdoor unit - MIM-B13D For connecting Centralized control system
Centralized Control
Communication F1, F2 Interface Module Interface Module MIM-N10 MIM-N10 ERV

FCU interface module MIM-F10N

EEV Kit Compatible interface module MIM-N01 MIM-N01 Old & New protocol
Zone Control Package
MWR-ZS00N MWR-ZS00 Duct S Inverter Models
(Zone Controller & Relay)
Zone Controller MWR-ZS10N MWR-ZS10 Duct S Inverter Models
EEV Control MWR-WE11N 360 CST air folw display
Wired Remote Controller MWR-WE10N MWR-WE10 Cassette, Duct & Ceiling
Liquid Pipe MWR-WW00N - DVM S Hydro Unit

CAC
Wired Remote Controller MCM-A00N For DVM chiller

Wired Remote Controller MWR-TH01 Cassette, Duct & Ceiling

MWR-WH00 Connect Wire length : 10m (SEC)


Wired Remote Controller -
MWR-WH02 Connect Wire length : 3m (SSEC)
System
Controller MWR-SH10N Touch controller, Built in Temperature sensor

MWR-SH00N MWR-SH00

Eva in AHU Fan Control


Controller MWR-VH12N MWR-VH02 ERV
Sensor Sensor
Wireless Remote Controller (H/P) MR-EH00 MR-EH00
Return Air Exhaust Air Fresh Air Individual
Supply Air Control System Wireless Remote Controller (C/O) MR-EC00 MR-EC00
MR-DC00
MR-DH00
MR-AC01

FJM
Room Wireless Remote Controller MR-AH01 Cassette, Duct & Ceiling
Sensor
AR-KH00E

Fan Feedback Wi-Fi Kit MIM-H03N


MIM-H03
MIM-H03R (*)

- MIM-A00
AHU Controller contact interface module
DVM S Series (for Ducted indoor unit)
MRK-A10N MRK-A10N
Wireless Signal Receiver package Single Global Duct
Gas pipe (With Receiver wire) MRK-A00
Duct (Wireless remote controller)
MRW-10A
Eva_out Sensor
MRW-TA MRW-TA

CONTROL SYSETM
Sensor MRW-TS MRW-TS For Zone Controller

ERV CO2 Sensor MOS-C1 MOS-C1

S-Converter (S-NET Pro) MIM-C02N MIM-C02N Converter for communication with PC


Test Run Tool
S-Checker MIM-C10N - Connection with mobile device

2017 Samsung Air Conditioning Solutions 145 146 www.samsung.com/business


CONTROL SYSTEM CONTROL SYSTEM

INTRODUCTION
Accessories Accessories

MODEL Image Model APPLICATION


CLASSIFICATION IMAGE DVM S APPLICATION
(New Communication Protocol) 15.0 kW and below

MDP-E075SEE3D MDP-E075SEE3 Slim Duct(2.0 ~ 14.0 kW) Over 15.0 kW ~ 40.0 kW and below

DVMS OUTDOOR UNITS


MDP-M075SGU1D MDP-M075SGU1 M.S.P Duct(9.0/11.2 kW) Over 40.0 kW ~ 45.0 kW and below
M.S.P Duct(12.8/14.0 kW)
MDP-M075SGU2D MDP-M075SGU2
H.S.P Duct(11.2/14.0 kW) Over 45.0 kW ~ 70.3 kW and below

MDP-M075SGU3D MDP-M075SGU3 M.S.P Duct(5.6/ 7.1 kW)


Over 70.3 kW ~ 98.4 kW and below
Drain Pump
MDP-N047SNC0D Fresh Air Intake Duct (14.0 kW)
Over 98.4 kW ~ 135.2 kW and below
H.S.P Duct(22.4/28.0 kW)
MDP-N047SNC1D MDP-N047SNC1
Fresh Air Intake Duct (22.4/28.0 kW)
Over 135.2 kW
- MDP-G075SP

22.4 kW and below


- MDP-G075SQ Global Duct (Internal Type)
Over 22.4 kW ~ 70.3 kW and below
MXD-A38K2A - 8~12 HP

DVM S INDOOR UNITS


PDM Kits Over 70.3 kW ~ 135.2 kW and below
MXD-A12K2A - 14~16 HP
(High Elevation Kits)
Over 135.2 kW
MXD-A58K2A - 18~22 HP

MXD-K025AN - 7.0 ~ 8.75 kW AHU 135.2 kW and below

MXD-K050AN - 14.0 ~ 17.5 kW AHU 140.2 kW and Over

MXD-K075AN - 21.0 ~ 26.25 kW AHU


135.2 kW and below
AHU Kits
MXD-K100AN - 28.0 ~ 35.0 kW AHU
140.2 kW and Over
MXD-A64K100E - AHU EEV Kit (10HP)
45.0 kW and below (for 4 rooms)
MCM-D201N - Control Kit (PBA, 10HP~40HP)

Distribution Header 70.3 kW and below (for 8 rooms)


MVO-VA050100 - 500 CMH (ERV Plus)

Over 70.3 kW ~ 135.2 kW and below (for 8 rooms)


MVO-VA100100 - 1,000 CMH (ERV Plus)

PC4NUDMAN PC4NUDMAN NASA, Square MCU-S6NEK2N

CAC
PC4NBDMAN PC4NBDMAN NASA, Square - Black MCU-S4NEK3N
4 Way Cassette
Front Panel MCU
PC4NUNMAN PC4NUNMAN MCU-S2NEK2N

PC4NBNMAN PC4NBNMAN
MCU-S1NEK1N
PC4NUSKA (Korea)
PC4NUSKAN
PC4NUSMA (China)
MXD-E24K132A
PC4NUSKE (Korea)
PC4NUSKEN 4Way Cassette S - Classic
PC4NUSME (China)
MXD-E24K200A 2 Indoor
4 Way Cassette 4Way Cassette S - Classic
PC4NUSKFN
Front Panel (North America)
MXD-E32K200A
PC4NBSKAN PC4NBSKA 4Way Cassette S - Black

MXD-E24K232A
- P4SMA 4Way Cassette

EEV Kit MXD-E24K300A


PC4SUSMAN PC4SUSMB

FJM
4 Way Cassette 3 Indoor
PC4SUSMEN PC4SUSMF MXD-E32K224A

PC1MWSKAN, PC1NWSMAN, PC1BWSMAN - 1Way Cassette (New Air Fluid Design) (1.7~2.2kW)
MXD-E32K300A
Slim 1Way Cassette
PC1NUSMAN PSSMA
(2.2~3.5kW)
MEV-E24SA
Slim 1Way Cassette
1 Way Cassette Front Panel PC1BWSEAN - 1 Indoor
(5.6~7.1kW)
Slim 1Way Cassette Z-Sliding MEV-E32SA
PC1NUPMAN PC1NUPMA
(2.2~3.5kW)
Slim 1Way Cassette Z-Sliding MXD-A38K2A 8~12 HP
PC1BWPEAN -
(5.6~7.1kW)

2 Way Cassette Front Panel PDM Kit MXD-A12K2A 14~16 HP

CONTROL SYSETM
PC2NUSMEN 2Way Cassette

4Way Cassette S
MSD-CAN1 MSD-CAN1 MXD-A58K2A 18~26 HP
Virus Doctor
MSD-EAN1 MSD-EAN1 ERV, Global Duct

Motion Detect Sensor MCR-SMA MCR-SMA

2017 Samsung Air Conditioning Solutions 147 148 www.samsung.com/business

S-ar putea să vă placă și