Documente Academic
Documente Profesional
Documente Cultură
Job Title
Software Consultants (Pty) Ltd Client
Internet: http://www.prokon.com
E-Mail : mail@prokon.com Calcs by Checked by Date
-500
500
Y
Design approach:
The column is designed using the following procedure:
(1) The column design charts are constructed.
(2) The design axis and design ultimate moment are determined .
(3) The design axial force and moment capacity is checked on
the relevant design chart.
(4) The procedure is repeated for each load case.
(5) The critical load case is identified as the case yielding the lowest
safety factor about the design axis
Through inspection:
Load case 12 is critical.
lo = ß . l
= .75 ×5.6
= 4.200 m
+ =
Mxbot=22.3 kNm
+ =
Mybot=16.8 kNm
Interaction Diagram
20E3
12E3
Axial load (kN)
10E3
8000
6000
4000
-2500
-2000
-1500
-1000
2000
1000
1500
2000
2500
3000
-500
0.00
500
627 kNm
-2000
Moment distribution along the height of the column for bending about the design axis:
The final design moments were calculated as the vector sum of the X- and Y- moments
of the critical load case. This also determined the design axis direction
Stresses at the top end of the column for the critical load case 12
Eurocode 2 - 2004
Y D
M
500
74.4°
74.4°
X X
0
-500
-500
500
M
D Y
0
Safety
Load case Axis N (kN) M1 (kNm) M2 (kNm) Mi (kNm) Madd (kNm) Design M (kNm) M' (kNm) factor
Safety
Load case Axis N (kN) M1 (kNm) M2 (kNm) Mi (kNm) Madd (kNm) Design M (kNm) M' (kNm) factor
Safety
Load case Axis N (kN) M1 (kNm) M2 (kNm) Mi (kNm) Madd (kNm) Design M (kNm) M' (kNm) factor
Safety
Load case Axis N (kN) M1 (kNm) M2 (kNm) Mi (kNm) Madd (kNm) Design M (kNm) M' (kNm) factor
-500
500
Y
Design approach:
The column is designed using the following procedure:
(1) The column design charts are constructed.
(2) The design axis and design ultimate moment are determined .
(3) The design axial force and moment capacity is checked on
the relevant design chart.
(4) The procedure is repeated for each load case.
(5) The critical load case is identified as the case yielding the lowest
safety factor about the design axis
Through inspection:
Load case 12 is critical.
lo = ß . l
= .75 ×5.21
= 3.907 m
+ =
Mxbot=93.9 kNm
+ =
Mybot=337.4 kNm
Interaction Diagram
20E3
12E3
Axial load (kN)
10E3
8000
6000
4000
-2500
-2000
-1500
-1000
2000
1000
1500
2000
2500
3000
-500
0.00
500
1188 kNm
-2000
Moment distribution along the height of the column for bending about the design axis:
The final design moments were calculated as the vector sum of the X- and Y- moments
of the critical load case. This also determined the design axis direction
Stresses at the top end of the column for the critical load case 12
Eurocode 2 - 2004
Y D
M
500
252.6°
252.6°
X X
0
-500
-500
500
M
D Y
0
Safety
Load case Axis N (kN) M1 (kNm) M2 (kNm) Mi (kNm) Madd (kNm) Design M (kNm) M' (kNm) factor
Safety
Load case Axis N (kN) M1 (kNm) M2 (kNm) Mi (kNm) Madd (kNm) Design M (kNm) M' (kNm) factor