Documente Academic
Documente Profesional
Documente Cultură
2018 Statistical analysis of electrical and mechanical breakdown stress for insulation performance in high voltage power transformer
Statistical analysis of electrical and mechanical breakdown stress for insulation performance in high voltage power transformer
Nihat Pamuk
Abstract
In electrical power system, variety of solid, liquid and gaseous materials are used for insulation target to protect the incipient failure inside the
high voltage power transformers. The insulation is practically ended when the insulation system has become fragile enough to ourish cracks
under the electrical and mechanical stresses to which it is subjected. The electrical and mechanical stresses are induced by short circuit
currents, thermal expansion and contraction of the conductors and vibration. The dielectric strength of insulation is not vitally diminished by
brittleness alone, but electrical breakdown will rapidly follow the improvement of ensuing cracks. The purpose of this paper is to brie y cover
the methods favourable for determining the insulating value of the insulation on high voltage power transformer windings and bushings. Many
failures of insulation are caused by the entrance of moisture. Insulating materials used on high voltage power transformer windings have a
high af nity for moisture from the surrounding atmosphere or oil. Effects of the stressed oil volume and stressing time on the breakdown
stress of high voltage power transformer insulation were experimentally investigated. The factors in uencing the effects and the results
obtained based on them were statistically analysed and systematized by the Weibull distribution method. A Four-dimensional volume theory
allowing good estimation of breakdown stress in terms of speci c probable values has been established.
Request full-text
Citations (4) References (13)
Identi cation of Critical Values Based on Natural Ester Oils as Potential Insulating Liquid for
High Voltage Power Transformers
Article Dec 2017
Nihat Pamuk
View
... In this concept stressed oil volume is roughly 500 ÷ 5000 cm 3 for oil gaps width 3 ÷ 30
mm. This is considered to be suf cient to obtain smaller deviation of test results
according to literature [6,9, 23] . Stressed oil volume is calculated between at surfaces of
electrodes. ...
https://www.researchgate.net/publication/289278422_Statistical_analysis_of_electrical_and_mechanical_breakdown_stress_for_insulation_perfor… 1/3
17.08.2018 Statistical analysis of electrical and mechanical breakdown stress for insulation performance in high voltage power transformer
P Gabrić A Mikulecky D Ilić
View Show abstract
... Crude vegetable oils extracted from oil seeds have a dark colour and include solid
constituents such as bres, proteins and liquid [9]. Both fats and oil are triglyceride esters
of fatty acids, but fats include a relatively high percentage of saturated triglyceride and
would freeze to solid below room temperature [10] . Inherently, the palm oil is de ned as
stabilized oil owing to its chemical combinations. ...
Investigation of the usage of palm oils with the aim of insulation in high voltage power system
equipments
Article Oct 2015
Nihat Pamuk
View
Recommended publications
Discover more publications, questions and projects in High Voltage
Article
Electric power systems include a large number of expensive and crucial power cable systems over many decades. Every power cable is composed of at least two
components; an electrical conductor, and the conductor insulation which prevents direct contact or unsafe proximity between conductor and other objects. The
need to provide adequate electrical insulation which will also permit heat to be... [Show full abstract]
Read more
Article
Power transformer is one of the most expensive and strategically signi cant components of any power system, so that they are crucial parts of high voltage
energy generation and transmission systems. Therefore their function is essential to power system reliability. This paper presents the life and long term
degradation of oil impregnated cellulosic insulating materials used in power... [Show full abstract]
Read more
https://www.researchgate.net/publication/289278422_Statistical_analysis_of_electrical_and_mechanical_breakdown_stress_for_insulation_perfor… 2/3
17.08.2018 Statistical analysis of electrical and mechanical breakdown stress for insulation performance in high voltage power transformer
Article
Identi cation of Critical Values Based on Natural Ester Oils as Potential Insulating Liquid
for Hig...
December 2017 · Journal of Polytechnic
Read more
Conference Paper
The problem of a high-voltage applied to a wedge-shaped oil gap in power transformers is considered as far as induced distortions and tangential electric stresses
are concerned. Near-tip distortions and electric stress concentration occur due to the essentially difference in the relative permittivity between the insulating oil
and the pressboard. When the magnitude of tangential electric... [Show full abstract]
Read more
Discover more
https://www.researchgate.net/publication/289278422_Statistical_analysis_of_electrical_and_mechanical_breakdown_stress_for_insulation_perfor… 3/3