Sunteți pe pagina 1din 2

IMS Specifications

Sensing method Through-beam Diffuse reflective Retro reflective

NPN E3TT -N E3TD -N E3TR -N

E3T-
Model
PNP E3TT -P E3TD -P E3TR -P
5~30mm(Non-glossy white
Sensing distance 0~500mm/1m 100mm(*1) 200mm(*2)
paper50*50mm)

Compact Photoelectric Sensor Sensing object


Opaque materials of
Opaque materials Opaque materials
max. φ2mm

INSTRUCTION MANUAL
Opaque materials of φ0.5mm(sensing distance φ2mm(sensing
Min. sensing target
φ2mm 10mm) distance100mm)

Max. 20% at rated sensing


! WARNING Hysteresis
distance

Response time Max.1ms


Thank you for selecting IMS product.This sheet primarily describes precautions
required in installing and operating the product.Before operating the product,read Power supply 10~30VDC(including ripple Max.10%(p-p))
the sheet thoroughly to acquire sufficient knowledge of the product.For your Current consumption Max. 20mA
convenience,keep the sheet at your disposal.
Light source Red LED(650nm)

! CAUTION Operation mode Light ON/Dark ON

Output NPN or PNP open collector output


Failure to follow these instructions may result in serious injury or death:
Fail-safe device must be installed when using the unit with machinery that may Load current Max. 100mA (Residual voltage:Max. 3V),Load voltage:Max. 26.4VDC
cause serious injury or substantial economic loss. (e.g. nuclear power control, Reverse polarity protection、output shot-circuit protection、
Circuit protection
medical equipment, ships, vehicles, railways, aircraft, combustion apparatus, Over current protection
safety equipment, crime/disaster prevention devices,etc.) Indicators Operation indicator:Red,Output indicator:Green
Failure to follow these instructions may result in product damage:
Insulation resistance Min. 20MΩ ( at 500VDC megger )
Do not use this unit over rated voltage;
Do not use this unit where there is flammable or explosive gas; Noise strength ±240V the square wave noise(pulse width:1μs)by the noise simulator
Do not use this unit where there is vibration or impact; Dielectric strength 1000VAC 50/60Hz for 1 minute
In cleaning the unit, do not use water or an oil-based detergent.
1.5mm or 300m/s² amplitude at frequency of 10 to 55Hz in each of
Vibration resistance
X,Y,Z direction for 2 hours
Ordering information
Shock resistance 500m/s² in X,Y,Z directions for 3 times
E3T D 1 M N L T C (Light source code) Sunlight:Max. 11,000lx ,
Ambient illumination
Incandescent lamp:Max. 3,000lx (Receiver illumination)
Connection type L Cable type
C Connector type Ambient temperature Operation:-25 ~ 55 ℃,Storage:-40 ~ 70 ℃(with no icing)

Response time 1ms Ambient humidity Operation and storage:35 ~ 85 %RH(with no condensation)
M 0.25ms Degree of protection IP64(IEC standards)

Sensitivity T available Material Case:PBT,Lens:PMMA


Fixed
φ2.6mm,3P,Length:2m (Through-beam type:3P/4P,Length:1.5m)
L Light on Cable (AWG28,Core wire diameter 0.08mm,No. of core wire:16,Insulator
Operation mode
D Dark on out diameter:0.8mm)
S Selectable
Accessory Fixing bracket,screw
N NPN
P PNP Weight Approx. 40g Approx. 25g
Output O NPN+PNP
D 5V (*1) Reflector:KY-R4
C Relay (*2) Reflector:KY-6
A Analog
Sensing distance unit Unit:mm
Sensing distance M Unit:m Control output circuit diagram
(slot series use 30/50 to refer slot distance)
Number Sensing distance
① NPN open collector output
T Through-beam
Sensing method(slot series is none) D Diffuse reflective
R Retro reflective (Brown)+V
V Convergent Reflective
B Polarization opaquing
Stability Load
Item
E3T Photoelectric sensor (green) Over (Black)
output
Main circuit

current
Operation protection
Control box (red) Max.100mA
10-30VDC

Functions of indicators and keys


(Blue)0V
LED1:sensor output status
LED2:transmission power adjustment status
Key1
Key1:Increase the transmitting power
Key2:Reduce the transmitting power Key2
② PNP open collector output
Operation instruction
Short press key1 one time:Increase the transmitting power slightly. When the power (Brown)+V
up to the maximum, LED2 will blink at an interval of 0.25s.
Short press key2 one time:Decrease the transmitting power slightly. When the power
down to the minimum, LED2 will blink at an interval of 0.5s. Stability
(green) Over (Black)
Long press key1:When the long press time reaches 2s, the transmitting output
Main circuit

current
Operation protection
power will continue to increase. The voltage will no longer change after release the (red) Max.100mA
10-30VDC
button. When the LED2 flashing, it means the power reaches the maximum. Load
Long press key2:When the long press time reaches 2s, the transmitting power will
(Blue)0V
continue to decrease. The voltage will no longer change after release the button.
When the LED2 flashing, it means the power reaches the minimum.
Save setting:The parameter will be automatically saved to EEPROM and does not
need to be set next power on.
Connections Mounting & Adjustment
Through-beam Diffuse reflective Installation
Confirm that the sensing surface of sensor is parallel with the surface of each sensing
object.

Please use screw M2 to mount the sensor,set the tightening torque under 0.3N.m.

※1:Load connection for NPN output;


※2:Load connection for PNP output;

Operating timing diagram

When installing the sensor, please refer to the direction of movement of the detected
object.(refer to the following)

Optical axis adjustment


After placing the sensing target, adjust the sensor up and down, left and right to
determine the indicator operation area, and fix the sensor in the center of the area.
Diffuse reflective

※ The waveforms of”Operation indicator”and”Transistor output”are for Light on mode.


Retro reflective
Dimensions
Through-beam type

(Emitter) (Receiver)
OPR:Operation STB:Stability
indicator indicator
( Red) ( Green)

Optical axis Optical axis

Caution for using


of emitter of receiver

1、Please make sure the wiring is correct before power-on.


2、Use a visor or a hood so that excessive light(e.g. sunlight, spotlight)does not directly
enter into the inclination angle of the sensor.
3、When more than 2 sets of Through-beam type sensor are used closely,it might cause inter-
Cable φ2.6 Cable φ2.6 ference to each other. Be sure to put enough space between them in order to avoid malfunction.
1.5m 1.5m
4、Sensor can mulfunction due to light entering from adjacent sensor, so sensors must be
installed with enough seperated distance.
Diffuse reflective type 5、If the sensor is installed directly on a flat surface, the reflection off the surface may cause
malfunction. Make sure there is enough space between the sensor and the surface.
6、If the sensor is wired with a high voltage line or power line, it may cause product damage
or malfunction. Use separate wiring or a dedicated conduit.
7、Please use short cables for wiring the sensors. Power surge from extended wiring may cause
product malfunction;
8、When the lens is stained by foreign substances, clean the lens lightly with dry cloth. Do not
use chemical or organic solvents.

Main product
Photoelectric sensor Liquid level sensor
Light curtain Label sensor
Proximity sensor Hall sensor
Pressure sensor Pressure meter
Counting sensor Counting machine
Control box
Distance sensor Dust sensor

Intellisense Microelectronics
Tel:0592-8268993
Tax:0592-8268997
Web:www.chinasensors.cn
E-mail:sales@chinasensors.com.cn
Add:1F NO. 34 Guanri Rd, Xiamen software Park,Xiamen P.R. China

S-ar putea să vă placă și