Sunteți pe pagina 1din 2

TDS software

Scope:

After creating Inputs data of transformer, software create detailed inputs according to
data base setups that included in .Software creates total Practical Variants that Satisfies
Limits and orders of User. This limit defines as setups for software according to
workshop limits or other matters. Created variants, can be sorted by very parameters that
generated by software like TOC (Total ownership cost), Weight of core, weight of total
transformer, Height of transformer, losses;. Local target for TOC in windings is ( A*Gcu
+ C*PK + E * Gpsp + F*Gpap ) and local Target for TOC in core is (B*Gfe + D*P0 ) .
After sorting, the best design can be choice by user as final design . Out put of soft ware
includes a lot of information about details of transformer that may be quoted to customer.
This software creates transformer designs from 2MVA till 600MVA (in single and
1800MVA in three phases) and 0.4KV to 750KV.

Summary of capabilities:

1. All type of transformers such as separate winding, auto and multi-winding, Furnace,
Multi-limb transformers can be designed.
2. Designing of Single or three-phase transformer with multiple core construction (3/0,
3/2, 2/0, etc.) is possible.
3. Off-Circuit as well as On-Load Tap changing type for each Terminals.
4. All tap-changing system such as Bridge, Linear, Reverse, Coarse-Fine system
5. Any winding arrangement in radial direction.
6. Any winding types: Layer, Disk, Helical, IL and other special types for regulating
windings and also any user defined type can be designed.
7. Optimization variants of design by considering TOC (Total Ownership Cost) and
also any user defined. In this software optimization done in two steps: 1) Automatic
analyzing step: software in step 1 of automatic analyzing find best cooling channels
position inside core for best temperature distribution in every variant in different parts of
core stack between two axial cooling channels of core.2) Automatic analyzing step:
software in step 2 of automatic analyzing find best wire, turn of windings , width of
windings , Height of windings ,Losses,... for TOC calculation.
8. All load combination modes are creating automatically by software and all related
parameters such as losses, temperatures, Active and reactive magnetic field, Hot spots
etc, could be calculate automatically .
9. All one and three phase short circuit modes and related results such as forces, line
and phase currents, voltages , currant angle, etc in transformer and feeding and loading
transition lines can be calculated automatically by software. Also NGR parameters can be
checkered by these tools of software for evaluating of Neutral BIL.
10. All connection modes of tap windings to main windings in different tap position
create automatically for Calculation of Impedance Voltages between all Terminals in all
Tap positions.
11. Eddy losses of tank and yoke beams, pressing plates and other metal parts could be
calculated in any load mode by magnetic field method.
12. Short circuit forces in any short circuit modes with depended results such as inner
and outer forces, forces on clamping plate and end supports, number of radial and axial
supports , workshop forces , and also tensions in any part of windings and supports and
etc could be calculated.
13. Automatic check of input values for not defined or mistakes with full guide for user
to recheck it.
14. Automatic check and filtering and sorting output results in text and graph modes
according to user defined criteria.( for example if desired Impedance voltage in a
connection mode be very low or very high and software couldn't reach any result
automatically , this graph show 100% filtering for this.)
15. Calculation of inrush current in any terminal with depended parameters such as
damping time, pick and effective current in any switching angle, etc.
16. Auto analyze windings connection to create desired Vector Group and define best
choose for position of end leads of windings.
17. Over loading guide calculation for normal cyclic loading and long time emergency
loading acc. to IEC 60354 and related results such Minimum rest time ,ageing rate ,
K1 ,K2 , etc.
18. Auto suggestion of tap changer class for one and three phase transformer with
graphical guide for connection of windings to tap changer.
19. Series and parallel connection Parts of windings: all Windings Could be Connected
in Series parts on Different limbs or parallel parts on Different limbs or Series parts on
same limbs or parallel parts on same limbs.
20. Segment base calculation for sub programs and exact calculation: Software
automatically create segments corresponding to windings for exact calculation in short
circuit forces, eddy losses of windings, etc.
21. Library analyzing: Library analyzing of Transformer is a very powerful and Flexible
tool for Refining and doing more calculation for automatic based designs.
22. Add or remove user for user list with Personal password for each user. This tool is
included for security and signing design by user.
23- any kind of oil field transformer like GENERATOR STEP-UP (GSU), Step down
transformer, AUXILIARY (UAT), STATION SERVICE (SST),TRANSFORMERS,
Mobile transformers, Very High current transformers , …

Optional:

In the case of difference between technologies included in this software with yours, it
could be possible to add or change in software.