Sales Enquiry Catalogue

Volume Dampers – AMCA 500D

Volume Control Damper – AMCA 500D – Single skin Blade Construction

Model :VCD-B11 / 21 A/B


(A-Parallel; B- Opposed Operation)
Construction :Galvanized Steel / Stainless Steel
Blade :3 – V Blade (Single Skin)
Leakage :Class- II
Installation :V/H
Drive :Manual (Quadrant)

Volume control dampers are square and rectangular type with both parallel blade operation and opposed blade operation, Low leakage blade
construction, is to suit for high performance applications where dampers are subjected to face quiet, efficient, rattle free operation.
VCD GB 10/20 Series is a galvanized steel high performance low leakage volume control damper, to ensure lowest resistance to airflow in HVAC systems
with velocities to 2000 fpm (10.2 m/sec.) and 4” w.g. (1000Pa) may be installed vertically or horizontally (with blades running horizontally) and is rated for
airflow and leakage class 2 in either direction. The standard construction is suitable for a leakage of air flow in either direction.

Volume Dampers – AMCA 500D

Volume Control Damper – Heavy Duty– Single skin Blade Construction

Model :VCD-B41A/B (A-Parallel; B- Opposed Operation)


Construction :Galvanized Steel/ Stainless Steel
Blade :3 – V Blade (Single Skin)
Leakage :Class- II
Installation :V/H
Drive :Manual (Quadrant)

Volume control dampers are square and rectangular type with both parallel blade operation and opposed blade operation, Low leakage blade
construction, is to suit for high performance applications where dampers are subjected to face quiet, efficient, rattle free operation.
VCD GB 40 Series is a galvanized steel high performance low leakage volume control damper, to ensure lowest resistance to airflow in HVAC systems with

https://beteccad.com/air-distributiongeneral/volume-control-dampers/volume-control-damper 1/2
12/10/2019 Volume Control Damper | BetecCad
velocities to 2000 fpm (10.2 m/sec.) and 4” w.g. (1000Pa) may be installed vertically or horizontally (with blades running horizontally) and is rated for airflow
and leakage class 2 in either direction.
CompanyThe|standard construction
News & Events is suitable
| Global Network for |a leakage of air flow in either direction.
Contact us SEARCH ‫ﺗﺣدﯾد اﻟﻠﻐﺔ‬
‫ﺗدﻋﻣﮫ‬

About us Products Catalogue Certifications Gallery Projects Sales Services

Quick Links Locations

About Us UAE USA Company


Products India Saudi Arabia News & Events
Catalogue Malaysia Qatar Global Network
Certifications Kuwait Oman Contact Us
Gallery Jordan Egypt
Projects Singapore South Korea
Sales Hong kong
Services

BETEC CAD. © 2015 . All rights reserved.

https://beteccad.com/air-distributiongeneral/volume-control-dampers/volume-control-damper 2/2

S-ar putea să vă placă și