LVM Series
Compact Direct Operated
Isolated structure
Diaphragm isolates the solenoid drive body from the fluid. [Option]
Solenoid
drive body
Area of
the fluid
Diaphragm Plate
Wetted part material (Metal free)
Body/Plate
PEEK
Choice of
VCH
VDW
LVM095
Note) Kalrez® is a registered trademark of E. I. du Pont de Nemours and Company or its affiliates.
527 A
Meeting the most advanced needs of process control
Compact Direct Operated 2/3 Port
Valve chamber volume Unit: µL
Diaphragm Difference
valve in volume Visible change
in volume
ON status OFF status
(Valve open) (Valve closed)
Rocker
type No change
ON status OFF status
in volume
Space-saving Unit: mm
Series LVM090 LVM10/100 LVM150 LVM200
Valve width 9.5 13 16 20
Manifold pitch 10.5 14 17 21 C
Valve width A
Highly integrated resin manifold
Material: Acrylic (Made to Order)
· Highly flexible fluid path design
· Steric fluid path structure
· Simplification of piping
· Visualization of the fluid B
528
LVM Series
Solenoid Valve for Chemical Liquids [Option]
Piping/Mounting Variations
Body ported
• M5 thread • Tubing type
Manual
(Option)
Bracket (Option)
Bracket
(Option)
2 x M5 x 0.8 Tubing
Base mounted
Without sub-plate
VCH
VDW
SX10
O-ring
VQ
LVM
B • With sub-plate
A
LVM
(Rocker type)
Material: Material:
PFA or PVDF PVDF Material:
PVDF
A Valve chamber volume
B Body/Plate material∗: PEEK
C Diaphragm material:
EPDM or FKM or Kalrez®
∗ Plate material PFA can be selected for the LVM10/100
base mounted type. LVM10/100 LVM15/150 LVM20/200
Kalrez® is a registered trademark of E. I. du Pont de
Nemours and Company or its affiliates.
529 A
Series Variations
Orifice Valve
Valve Number Operating pressure
Model Valve type diameter width
construction of ports range
(mm) (mm)
LVM09R3 N.C.
Diaphragm type 2
direct operated
LVM09R4 poppet N.O. −75 kPa to 0.2 MPa 1.1 9.5
(Rocker type)
LVM095R Universal 3
Diaphragm type
LVM11 direct operated N.C. 2 0 to 0.25 MPa 1.5 13
poppet
LVM10R1 N.C.
2
LVM10R2 N.O. −75 kPa to 0.25 MPa 1.4 13
LVM102R Universal 3
LVM10R3 N.C.
LVM10R4 N.O. 2
−75 kPa to 0.25 MPa 1.4 13
LVM10R6 N.C.
LVM105R Universal 3
LVM15R3 N.C.
Diaphragm type 2
direct operated
LVM15R4 poppet
N.O. −75 kPa to 0.25 MPa 1.6 16
(Rocker type) (Max. 0.6 MPa) (1)
LVM155R Universal 3
LVM20R1 N.C.
2
LVM20R2 N.O. −75 kPa to 0.25 MPa 2 20
LVM202R Universal 3
LVM20R3 N.C.
2
LVM20R4 N.O. −75 kPa to 0.3 MPa 2 20
LVM205R Universal 3
530
LVM Series
Flow rate characteristics Fluid Volume Power
of valve Weight consumption
Water Air temperature chamber (g) Page
Kv[m2] Cv C[dm2/(S·bar)] b (°C) (µL) (W)
2.5
at inrush
0.034 0.04 0.13 0.22 11 30 P.535 to 539
1
at holding
P.535 to 541
0 to 50
0.025 0.03 0.1 0.2
(No condensation)
20 34 1.5 VCH
VDW
SX10
5.5 VQ
at inrush
0.034 0.04 0.13 0.22
(0.012) (0.015) (0.05) (0.2)
50 45 P.542 to 545 LVM
1
High-pressure type is
at holding indicated in brackets.
∗ The values of Kv and Cv are based on JIS B 2005:1995, C and b are based on JIB B 8390:2000.
531
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids
LVM09/090 Series
How to Order [Option]
A 532
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids LVM09/090 Series
u u
i i
y y
t t
r r
o o
e e
q q
w !0 w !0
VCH
LVM095R
VDW
u SX10
VQ
LVM
i
w !0
Kalrez® is a registered trademark of E. I. du Pont de Nemours and Company or its affiliates.
533 A
LVM09/090 Series
2 x ø2.1 13.6
Mounting hole
Approx. 5
3
5.5 4
32
LVM09R4
1 2 3
7
3
.6
.6
4 4 4 5.5
ø3
ø3
x
x
2
3
LVM095R LVM09R3
LVM09R3, LVM095R
534
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids
LVM10/100 Series
How to Order [Option]
Series
Number
Symbol Valve type Connection
of ports
102R 3 Universal 1
3 2
VCH
Body ported LVM 11 5 A
VDW
Base mounted LVM 10R3 5 A 1 SX10
Series CE-compliant VQ
Number Nil None
Symbol Valve type
of ports Q
Function
CE-compliant
LVM
Nil Standard
10R3 N.C. Y With power-saving circuit
Lead wire length
IN OUT Nil 300 mm
(Symbol 1) (Symbol 2) ∗ For the LVM11, the type with
power-saving circuit is standard. 6 600 mm
10 1000 mm
535 A
LVM10/100 Series
Specifications
Water Air
Valve construction
Kv Cv C b
Direct operated poppet 0.034 0.04 0.13 0.22
Rocker type 0.025 0.03 0.1 0.2
∗ The values of Kv and Cv are based on JIS B 2005:1995, C and b are based on JIB B 8390:2000.
Base mounted
(With sub-plate)
A 536
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids LVM10/100 Series
LVM10R1 LVM10R2
!2 !0 !2 !0
!1 !1
y y
t t VCH
u i u i VDW
o !3 o !3
SX10
r r
w e w VQ
e
q q LVM
LVM102R
537 A
LVM10/100 Series
!2 !0 !2 !0 !2 !0
!1 !1 !1
y y y
t t t
u i u i u i
o !3 o !3 o !3
r r r
w e w e w e
q !4 q !4 q !4
LVM105R
A 538
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids LVM10/100 Series
25.4
19
2 x ø3.2
UL1007
AWG22
52.5
M5 x 0.8 x 3.5
M5 x 0.8 x 3.5 IN port
OUT port
5
5
2
0.8
16 13
LVM10R1-- (N.C.)
LVM10R2-- (N.O.) VCH
LVM102R-- (Universal)
VDW
SX10
(8.25) 1.8 VQ
LVM
Lead wire length
1 2 3
N.C. N.O.
13 16
5.5
2 x ø2.8
UL1007
AWG22 4.5
16.5
LVM10R2
57
1 2 3 1 2 3
14.6
7
5.1
2.6
9.5
5.5
3
5.5
2 x ø2.8 3 x ø2.8
12.5
4.5 4.5 4.5
16.5 16.5
LVM102R
∗ The broken lines indicate with bracket.
539
LVM10/100 Series
13 16 20.5
<13.5>
UL1007 16.5
AWG22 <18.5>
2 x ø2.2
7
(6.5)
Mounting hole
8.5
4
2x
ø3
4.5 .9
57.5
Push type
24.5
Manual override
1 2 3
LVM10R4
9.5
N.C. N.O.
7
∗ The figures in brackets < > indicate the values for PFA plate material
3
(wetted part material “E, F, G”). In the case of PFA plate material
(wetted part material “E, F, G”), there is no ø1.6 positioning hole.
(6.5)
(6.5)
4
8.5
8.5
8.5
3x 2x 2x
ø3. ø3. ø3.
4.5 4.5 9 4.5 9 4.5 4.5 9
24.5 24.5 24.5
8.5 ± 0.1
4.25
7
4.25
3 x ø1.5 2 x ø1.5 IN
C0.2 or less When using a positioning pin for C0.2 or less
mounting, please use ø1.5 and
1 (N.C), IN OUT
2 (COM), OUT height 2 or less.
Not required for LVM10R6
540
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids LVM10/100 Series
19 1 2 3
2 x ø3.5 Mounting hole N.C. N.O.
(16)
11
24.5
21
12
Plug 5 IN port
27
36 LVM10R4
13 16 1 2 3
N.C. N.O.
UL1007
AWG22
(16)
11
IN port 10 OUT port
LVM10R6
Push type
73.5
Manual override
1 2 3 1 2 3
N.C. N.O. N.C. N.O.
25.5
(16)
(16)
VCH
11
11
11
IN port
3 x M6 x 1, 1/4-28UNF 6 Plug 1 (N.C) port 10 3 (N.O) port
VDW
2
5
OUT port (LVM10R3, 10R4) 6
2 (COM) port (LVM105R) LVM105R
Plug (LVM10R6)
SX10
∗ The broken lines indicate with bracket.
13
VQ
2 x M3 x 0.5 Thread length 5
For direct mounting
LVM
ø 1.8
M6 x 1,1/4-28UNF
ø 3.8
5 0.2
7
Details of thread
541
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids
LVM15/150 Series
How to Order [Option]
Function CE-compliant
155R 3 Universal 1 Symbol Specifications Nil None
3 2 Y Standard (With power-saving circuit) Q CE-compliant
HY High-pressure type (With power-saving circuit)
i i
o o
y y
t t
u u
r r
w w
e e
q q
!0 !0
VCH
LVM155R
VDW
SX10
VQ
i
LVM
t
Component Parts: LVM15R3, 15R4, 155R
u No. Description Material
1 Plate PEEK
r 2 Diaphragm assembly EPDM/FKM/Kalrez®
3 Body PBT
4 Slide bushing assembly PPS/Stainless steel
w 5 Armature assembly —
6 Coil assembly —
e q 7 Sleeve SUY
8 Board assembly —
!0 9 Casing PBT
10 Interface gasket EPDM/FKM/Kalrez®
543 A
LVM15/150 Series
2 x ø2.7
10.5 Mounting hole
16
.15
R2
2x
5.5
2.5
48.6
5.5
15
2.
9
xR
2
1 2 3 LVM15R4
N.C. N.O.
.15
.15
ø1.4 depth 2.3 4.5 ø1.4 depth 2.3 4.5
R2
R2
2x
2x
2.5
2.5
5.5
5.5
.15 2x .15
R2 R2 R2
2x .15 2x
LVM155R LVM15R3
2 x M2.5 x 0.45
Min. 0
Min. 0
2 x M2.5 x 0.45
Effective thread length
Effective thread length
4.5 or more
4.5 or more
5.25 5.5
10.5 ± 0.1
10.5 ± 0.1
5.25
5.5
3 x ø2.1 2 x ø2.1 IN
C0.2 or less 4.5 3 (N.O) C0.2 or less 4.5
Not required for LVM15R3
1 (N.C), IN OUT
When using a positioning pin for 2 (COM), OUT When using a positioning pin for
mounting, please use ø1.2 and mounting, please use ø1.2 and
height 2 or less. height 2 or less.
544
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids LVM15/150 Series
33
27 2 x ø3.2
Mounting hole
22
15
16
UL1007
60.6
1 2 3
N.C. N.O.
VCH
(12)
VDW
7
7
6
M6×1,1/4-28UNF, None
ø3.8
ø2
LVM15R3: None
LVM15R4: None
LVM155R: 2 (COM.) port
5 0.2
Details of thread
545
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids
LVM20/200 Series
How to Order [Option]
Series
Number
Symbol Valve type
of ports
20R2 N.O.
IN OUT
(Symbol 3) (Symbol 2)
202R 3 Universal 1
3 2
205R 3 Universal 1
3 2 Wetted part material
Symbol Plate Diaphragm
A PEEK EPDM Sub-plate material/
B PEEK FKM Port size
C PEEK Kalrez® Nil Without sub-plate
1 Rc1/8 PVDF
1F G1/8 PVDF
1N NPT1/8 PVDF
A 546
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids LVM20/200 Series
Specifications
547 A
LVM20/200 Series
!0 !0
i i
o o
y y
t t
u r u r
!1 !1
e e
q q
w w
LVM202R
!0
i
o
y
Component Parts: LVM20R1, 20R2, 202R
t No. Description Material
u r 1 Plate PEEK
2 Diaphragm assembly EPDM/FKM/Kalrez®
!1
3 Body PBT
4 Slide bushing assembly PPS/Stainless steel
5 Armature assembly —
e 6 Coil assembly —
q 7 Sleeve SUY
8 Board assembly —
9 Casing PBT
10 Plug NBR
11 O-ring NBR
w
Kalrez® is a registered trademark of E. I. du Pont de Nemours and Company or its affiliates.
A 548
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids LVM20/200 Series
!0 !0
i i
o o
y y
t t
u r u r
!1 !1
e e
q q
w !2 w !2
VCH
LVM205R
VDW
SX10
!0 VQ
i
LVM
w !2
Kalrez® is a registered trademark of E. I. du Pont de Nemours and Company or its affiliates.
549 A
LVM20/200 Series
2 x ø3.4
13
Mounting hole
31
20 24
UL1007
1 2 3
N.C. N.O.
6
2 x ø3.4
6.8
LVM20R2
58
1 2 3 1 2 3
N.C. N.O. N.C. N.O.
9
6
2 x ø3.4 3 x ø3.4
LVM20R1 LVM202R
550
Compact Direct Operated
2/3 Port Solenoid Valve for Chemical Liquids LVM20/200 Series
13
2 x ø3.4
Mounting hole
31
20 24
UL1007
Approx. 300
.7
ø5
x
2
58
1 2 3 ø2 depth 3
N.C. N.O. 11 6.8
VCH
9
LVM20R4
11 11
VDW
ø2 depth 3 ø2 depth 3
SX10
VQ
5
3x
ø5.7 2x
ø5.7 LVM
LVM205R LVM20R3
13 ± 0.1
3 x ø2.3
C0.2 or less IN
2 x ø2.3
6.5 ± 0.1
551
LVM20/200 Series
18
25
33
20 24
UL1007
74
1 2 3
N.C. N.O.
8.5
8.5
552
LVM Series
Specific Product Precautions 1
Be sure to read this before handling the products. Contact SMC when it is used in
conditions other than the specifications.
Warning
1. Do not use this product in applications which may adversely affect human Please use a fan or take other measures to disperse heat and
life (e.g. medical equipment connected to the human body for drip infusion). keep temperatures within the specified range when mounting
the solenoid valves inside control panels, etc. Be especially
2. Confirm the specifications. careful when using three or more adjacent valves with mani-
Give careful consideration to the operating conditions such as the application, fluid folds and keeping them continuously energized for extended
and environment, and use within the operating ranges specified in this catalog. period, as this may result in dramatic increases in temperature.
3. Fluid 11. Low temperature environments
Be sure to confirm the compatibility between the component material Be aware that the valve changeover time becomes extremely long
and the fluid. when the ambient and fluid temperature becomes 15°C or less as
a reference when compared to the valve changeover time at room
4. Maintenance space temperature (approx. 25°C). Diaphragm material: Kalrez®
The installation should allow sufficient space for maintenance activities. Kalrez® is a registered trademark of E. I. du Pont de Nemours and
5. Fluid pressure range Company or its affiliates.
Fluid pressure should be within the allowable pressure range.
Selection
6. Ambient environment
Use within the allowable ambient temperature range. Be sure that the
fluid used does not touch the external surface of the product. Caution
7. Countermeasures against static electricity Leakage voltage
Take measures to prevent static electricity since some fluids can The leakage voltage should be 2% or less of the rated voltage. If
cause static electricity. the leakage voltage exceeds this value, solenoid valve may not
turn OFF.
8. Pressure (including vacuum) holding
It is not usable for an application such as holding the pressure Mounting
(including vacuum) inside of a pressure vessel because air leakage is
entailed in a valve.
9. Cannot be used as an emergency shutoff valve, etc.
Caution
1. Always tighten threads with the proper tightening torque.
The valves presented in this catalog are not designed for safety applications
such as an emergency shutoff valve. If the valves are used in this type of When mounting the solenoid valve, tighten it with the proper VCH
system, other reliable safety assurance measures should also be adopted. tightening torque shown below.
10. Extended periods of continuous energization Tightening Torque for Base Mounting VDW
If solenoid valves are to be continuously energized for extended periods of time, use Location Model Thread size Proper tightening torque N·m
valves with power-saving circuits to minimize the amount of heat released by the coil. LVM09R3, 09R4, 095R M2 0.1 to 0.14 SX10
Power-saving circuit waveform (example) Base mounted, LVM10R3, 10R4, 10R6, 105R M2 0.15 to 0.2
Current consumption
Body mounting LVM15R3Y, 15R4Y, 155RY M2.5 0.25 to 0.35 VQ
(At inrush 3.3 W) LVM20R3, 20R4, 205R M3 0.4 to 0.6
(At holding 0.9 W) 2. Mount the solenoid valve on the horizontal surface. LVM
Applicable model: All models
0V 3. Remove dust from the solenoid valve mounting surface
Approx. 100 msec
completely. The surface roughness of the mounting surface
Energization period of solenoid valve should be Rz3.2 or less.
Applicable model: Base mounted
∗ Power consumption for the waveform shown above is that of the LVM09/090.
∗ For the LVM15/150, the type with power-saving circuit is standard. 4. When mounting the solenoid valves next to each other, the valve
∗ For the LVM10/100, the inrush is 50 msec.
pitch should be the value or more shown in the table below.
When a solenoid valve without a power-saving circuit is continuously energized for
long periods of time, temperature increase from coil heat release can result in wors- Series LVM09/090 LVM10/100 LVM15/150 LVM20/200
ening performance and shortened service life of the solenoid valve, as well as ad- Valve pitch 10.5 14 17 21
verse effects on peripheral equipment in the vicinity. For this reason, when valves Applicable model: All models
are to be continuously energized for extended periods, use a fan or take other mea-
sures to disperse heat and keep valve surface temperatures at 70°C or less. Warning
The table below shows reference values for continuously energized
5. If air leakage increases or equipment does not oper-
valves (single unit) when surface temperature is 70°C or less.
ate properly, stop operation.
Series LVM09/090 LVM10/100 LVM20/200 After mounting, perform suitable function and leak tests to
Period of continuous confirm that the mounting is correct.
5 min. or less 30 min. or less 30 min. or less
energization
Duty ratio 50% or less
6. Since the body (orifice shape) is designed to elimi-
Ambient temperature 25°C or less
nate residual liquid, mounting in a vertical direction
Power-saving circuit
with the coil at the top is recommended.
None
When residual liquid is not considered, any mounting orienta-
∗ Duty ratio: ON time/(ON time + OFF time)
∗ For the LVM15/150, the type with power-saving circuit is standard. tion is available.
553 A
LVM Series
Specific Product Precautions 2
Be sure to read this before handling the products. Contact SMC when it is used in
conditions other than the specifications.
Caution Warning
1. Preparation before piping Liquid (chemicals)
Before piping is connected, it should be thoroughly blown out with air (flushing) Component crystallizes or clots depending on its nature. Leakage will occur
or washed to remove chips, cutting oil and other debris from inside the pipe. when a crystallized or clotted component is caught between the sealing parts.
2. When tubing is connected to the body ported solenoid valve, Take measures to clean such component if necessary.
insert the tubing straight into the insertion part for a complete fit. Water
Select appropriate tubing while referring to the table below. Install a filter strainer of about 100 mesh on the inlet side of the piping.
Tube inside Tubing outside diameter
Model
diameter (I.D.) (O.D.) (after mounting)
Air
Compressed air filtered with a filter with filtration rating of 5 µm or less,
LVM10R1, 10R2, 102R ø2.5 or less ø4.5 or less
which is mounted on the inlet side of the piping, should be used.
LVM20R1, 20R2, 202R ø3.1 or less ø6.8 or less
The holding force varies by the tubing material. Be sure to confirm the holding force of Operating Environment
each material before operation.
After connecting the tubing, care should be taken not to put excessive force (tensile
force, compression, bending, etc.) on the tubing. If an external force of 20 N or more is
applied to the insertion part, this may cause leakage or damage to the insertion part.
Warning
1. Do not use the product in a place where there is
3. When the tubing is long or according to the operating conditions,
contact with corrosive gases, chemicals or liquids.
tubing may thrash about, causing damage to the tubing insertion
part of the solenoid valve, or the tubing to come off or deteriorate. 2. Do not use in explosive atmospheres.
In this case, secure the tubing to prevent its uncontrolled movement. 3. Do not use in locations subject to excessive vibration or impact.
Impact resistance of this solenoid valve is 150 m/s2. Vibration
4. When piping the fitting to the solenoid valve, the installation resistance of this solenoid valve is 30 m/s2.
method and tightening torque value may vary depending on the
4. Do not use in locations where radiated heat will be
seal structure (shape) or material of the fitting to be used. Check
received from nearby heat sources.
the methods and precautions recommended by the fitting manu-
facturer to be used, and be sure to check for leakage.
Maintenance
The table below shows the tightening method using the KQ series.
Model Location Thread size
Tightening
method
Tightening torque N·m
(Reference)
Warning
After tightening by hand, 1. Removing the product
LVM11 Body M5 tighten 1/6 to 1/4 turn with Material PEEK: 0.5 to 0.7 Shut off the fluid supply and release the fluid pressure in the
a tightening tool. system. Shut off the power supply. Remove the product.
LVM10R3, 10R4,
After tightening by hand,
Material PVDF: 0.6 to 0.8 2. Before operating, remove residual chemicals and
M6 or 1/4-28UNF tighten 1/6 to 1/4 turn with
10R6, 105R a tightening tool.
Material PFA: 0.2 to 0.25 completely replace it with deionized water, air, etc.
After tightening by hand, 3. Do not disassemble the product.
LVM15R3Y, 15R4Y, M6 or 1/4-28UNF tighten 1/6 to 1/4 turn with Material PVDF: 0.6 to 0.8 Products which have been disassembled cannot be guaran-
155RY Base mounted a tightening tool. teed. If disassembly is necessary, contact SMC.
(With sub-plate)
Tighten approximately
Rc1/8 or NPT1/8 Material PVDF: 0.5 to 0.6
LVM20R3, 20R4,
4 turns. Return of Product
205R After tightening by hand,
G1/8 tighten 1/3 to 1/2 turn with Material PVDF: 0.4 to 0.6
a tightening tool. Warning
If the product to be returned is contaminated or is
Wiring possibly contaminated with substances that are
harmful to humans, for safety reasons, please
contact SMC beforehand and then employ a special-
Caution ist cleaning company to decontaminate the product.
1. Use electrical circuits which do not generate chattering in their contacts. After the decontamination prescribed above has
2. Use voltage which is within ±10% of the rated voltage. been carried out, submit a Product Return Request
However, when the response time is important, control the Sheet or the Detoxification/Decontamination Certifi-
voltage to avoid variation on the minus side. cate to SMC and await SMC’s approval and further
3. Apply the correct voltage. instructions before attempting to return the item.
Applying incorrect voltage may cause a malfunction or a burned coil. Please refer to the International Chemical Safety
4. Connect the wires so that an external force of Black Red Cards (ICSC) for a list of harmful substances.
greater than 10 N is not applied to the lead wire. If you have any further questions, please don’t hesi-
Otherwise the coil will burn. tate to contact your SMC sales representative.
5. Units with power-saving circuits use
polarized electrical connections.
Red (+), Black (–) Lead wire color
A 554