28 Name Heater Duty Reactor Cooling Prod Cooler Duty Recyl Comp Power Condenser Duty
29 Heat Flow (kJ/h) 1.629e+006 -1.151e+006 3.131e+006 2.327e+004 1.446e+006
30 Name Reboiler Duty Pump Power
31 Heat Flow (kJ/h) 2.367e+006 5957
32
33
Unit Ops
34 Operation Name Operation Type Feeds Products Ignored Calc Level
35 Feed Stream Mixed
Recycle Mixer Mixer No 500.0 *
36 Recycle
37 Mixed To Reactor
Feed Heater Heater No 500.0 *
38 Heater Duty
39 To Reactor Dummy Liquid
40 Reactor Cont. Stirred Tank Reactor Reactor Cooling From Reactor No 500.0 *
41 Reactor Cooling
42 From Reactor Condensed Mixture
E-100 Cooler No 500.0 *
43 Prod Cooler Duty
44 Condensed Mixture Liquid
V-100 Separator No 500.0 *
45 Vapour
46 Vapour Purge
Purge Splitter Tee No 500.0 *
47 Recycled
48 Recycled To Recycle
Recycle Compressor Compressor No 500.0 *
49 Recyl Comp Power
50 Recycle Recycle To Recycle Recycle No 3500 *
51 Liquid Methanol
52 Reboiler Duty Dummy
Distilation Distillation No 2500 *
53 Water
54 Condenser Duty
55 Water Source To Condenser
P-100 Pump No 500.0 *
56 Pump Power
57 Methanol Final Product
Condenser Heat Exchanger No 500.0 *
58 To Condenser Water Return
59 ADJ-1 Adjust No 3500 *
60 Final Product shipping
Methanol Storage Tank No 500.0 *
61 Vent
62
63 Hyprotech Ltd. Aspen HYSYS Version 2006 (20.0.0.6728) Page 2 of 2
Licensed to: LEGENDS * Specified by user.