EN4604-005 WL
---------- -
| |
| ------------ Wire type code
|
------------------- Standard P/N (Not written on the wire)
(Ref. para. 4)
3. Wire Types
There are two families of wire types:
A. United States (US)
The United States (US) wire types are installed on A300/A310/A300-600. Their core diameter has US diameters.
e.g. AKA gauge 24 has 19 strands diameter 0.127 mm (0.0050 in.) .
B. Metric (M) types:
The Metric (M) wire types are installed on the other Airbus A/C for weight saving.
e.g. CF gauge 24 has 19 strands diameter 0.12 mm (0.0047 in.) .
C. Wire type interchangeability table
NOTE: The tables that follow give the interchangeability between wire types. for example, if a DK is not available, you can replace it by a DM.
Although these wires have different structures, they are fully interchangeable (for a given marking type).
| RH | RK |
|--------|--------|
| ST | GJ |
|--------|--------|
| TT | MH |
|--------|--------|
| UE | UU |
-------------------
(b) ABS -> EN
-------------------
| WIRE | WIRE |
| TYPE | TYPE |
| CODE | CODE |
|--------|--------|
| VJ | VV |
|--------|--------|
| VR | MJ |
---------|---------
(c) ABS/ASNE/EN -> EN
-------------------
| WIRE | WIRE |
| TYPE | TYPE |
| CODE | CODE |
|--------|--------|
| DK/DM | DR |
|--------|--------|
| PG/PN | DRB |
|--------|--------|
| QG/QL | DRC |
|--------|--------|
| RH/RK | DRD |
|--------|--------|
| ST/GJ | MLA |
|--------|--------|
| TT/MH | MLB |
|--------|--------|
| UE/UU | MLC |
|--------|--------|
| VJ/VV | MLD |
|--------|--------|
|HA/VR/MJ| MME |
------------------|
4. Wire Type Codes
NOTE: The tables that follow give the characteristics and the related P/Ns for each wire type. For a wire type code, if there are several related P/Ns, these wires have the same structure and the P/Ns are fully interchangeable.
Tables 1-A to 1-Y give the list of the wire type codes in alphabetic sequence and the related standard P/Ns (US and Metric wire type families).
It is the wire type code which is written on the wire and not the standard P/N.
NOTE: You must use the applicable tools to strip the wires (US or Metric). Refer to ESPM chapter 20-25-11.
TABLE 1-A
-------------------------------------------------------------------------------
| Single-core and Multicores Identification Coding |
| Normal Use - Unshielded - T < 200 C (392 F) |
-------------------------------------------------------------------------------
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
-------------------------------------------------------------------------------
| AD | Aluminum (UV laser | PI/PTFE | |ABS0949 |
| | marking) | | | |
| |180 deg.C (356 deg.F)| | | |
| ADA | Aluminum (Ink jet | PI/PTFE 1 ADA | |ABS1354 |
| | marking) | Single-core | | |
| |180 deg.C (356 deg.F)| Use only for | | |
| | |multicore cable| | |
| | | | | |
| ADB | Ink jet marking | PI/PTFE 2 ADA| |ABS1354 |
| |180 deg.C (356 deg.F)| | | |
| ADC | Ink jet marking | PI/PTFE 3 ADA| |ABS1354 |
| |180 deg.C (356 deg.F)| | | |
| ADD | Ink jet marking | PI/PTFE 4 ADA| |ABS1354 |
| |180 deg.C (356 deg.F)| | | |
| ADE | Ink jet marking | PI/PTFE 5 ADA| |ABS1354 |
| |180 deg.C (356 deg.F)| | | |
| AKA | 600V-200 C (392 F) | KAPTON/PTFE | ex AK |NSA935012 |
| AKB | 600V-200 C (392 F) | KAPTON/FEP | SNIAS 451242/78 |NSA935012 |
-------------------------------------------------------------------------------
TABLE 1-B
-------------------------------------------------------------------------------
| Single Wire Identification Coding |
| Panel Wiring - T < 200 C (392 F) |
-------------------------------------------------------------------------------
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
-------------------------------------------------------------------------------
| BE | 600V-200 C (392 F) | PTFE | MIL-W-16878 |NSA935041 |
| BF | 600V-200 C (392 F) | PTFE | |E0260 |
| BJ |180 deg.C (356 deg.F)| XL-ETFE | |ABS0826 |
| | (landing gear only) | | | |
| BP |180 deg.C (356 deg.F)| XL-ETFE | |ABS0820 |
| | (landing gear only) | | | |
-------------------------------------------------------------------------------
TABLE 1-C
-------------------------------------------------------------------------------
| Single Wire Identification Coding |
| Normal Use - Unshielded T = 200 C (392 F) |
-------------------------------------------------------------------------------
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
-------------------------------------------------------------------------------
| CF | 600V-200 C (392 F) | KAPTON/FEP | | E0261 |
| | (Ink jet or hot | | | |
| | stamp marking) | | | |
| | CF-C | FEP or PTFE | | E0261 |
| | (Co2 laser marking) | | | |
| | CF-U | FEP or PTFE | | E0261 |
| | UV laser marking) | | | |
| | CF-Y | FEP or PTFE | | E0261 |
| |YAG/X3 laser marking | | | |
-------------------------------------------------------------------------------
TABLE 1-D
-------------------------------------------------------------------------------
| Single-core and Multicores Identification Coding |
| Normal Use - Unshielded - T > 200 C (392 F) |
-------------------------------------------------------------------------------
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
-------------------------------------------------------------------------------
| DE | 600V | PTFE-KAPTON-PTFE | AIR 4524 |EN2267-008 |
| |260 deg.C (500 deg.F)| | |(ex. |
| | | | | NSA935130)|
| | | 2 DE | |EN2267-007 |
| | | | |(ex. |
| | | | | NSA935248)|
| | | 3 DE | |EN2267-007 |
| | | | |(ex. |
| | | | | NSA935248)|
| DG | 600V | KAPTON-GLASS-PTFE| AIR 4524 |NSA935131 |
| |260 deg.C (500 deg.F)| | | or |
| | | | |EN2854-003A|
| DJ | 600V | PTFE-FIREPROOF | AIR 4524 |NSA935132 |
| |260 deg.C (500 deg.F)| SILICA | | |
| DK | 600V | PTFE-KAPTON-PTFE | | E0262 |
| |260 deg.C (500 deg.F)| | | |
| | (Ink jet marking) | PTFE-KAPTON-PTFE | | E0262 |
| | DK-C | | | |
| | (CO2 laser marking) | | | |
| | DK-U | PTFE-KAPTON-PTFE | | E0262 |
| | (UV laser marking) | | | |
| | DK-Y (YAG X3 laser | PFFE-KAPTON-PTFE | | E0262 |
| | marking) | | | |
| DL | 600V | PTFE-FIREPROOF- | MIL-W-25038/3 | E0437 |
| |260 deg.C (500 deg.F)| SILICA | or prEN2234 | |
| DM | 600V | PI/PTFE | |EN2267-008A|
| | (UV laser marking) | Single wire | | |
| DMA | 600V | Single-core | |EN2267-007A|
| |260 deg.C (500 deg.F)| use only for | | |
| | (Ink jet marking) | multicore cable | | |
| TYPE | | | | |
| CODE | | | | P/N |
-------------------------------------------------------------------------------
| HA | 600V MULTI | 5 DK12 | | E0287 |
| |260 deg.C (500 deg.F)| KAPTON-PTFE | | |
| HB | 600V MULTI | 1 XE + 4 DK | | E0263 |
| |200 deg.C (392 deg.F)| KAPTON-PTFE | | |
| HC | 600V MULTI | 1 XE + 10 DK | | E0292 |
| |200 deg.C (392 deg.F)| KAPTON - PTFE | | |
| HD |MULTIWIRE AOP SYSTEM | 4 CF + RG316 | | E0299 |
| |200 deg.C (392 deg.F)| ADF SYSTEM | | |
| HE |BUS WIRE 200 C(392 F)| PTFE - KAPTON | | E0259 |
| HG |MULTIWIRE 600V- | 1 UD + 4 XM | | E0300 |
| |200 deg.C (392 deg.F)| FEP | | |
| HH |EXTENSIBLE CORD | CF-FEP sheath | | E0385 |
| |200 deg.C (392 deg.F)| | | |
| HL |EXTENSIBLE CORD | CF-FEP sheath | | E0488 |
| |200 deg.C (392 deg.F)| | | |
| HM |THERMOCOUPLE CHROMEL | PTFE | | E0527 |
| |260 deg.C (500 deg.F)| | | |
| HN |THERMOCOUPLE ALUMEL | PTFE | | E0528 |
| |260 deg.C (500 deg.F)| | | |
| HP |CHROMEL ALUMEL | HM + HN | | E0529 |
| |260 deg.C (500 deg.F)| PTFE | | |
| HQ |THERMOCOUPLE | FEP/POLYIMIDE | |ABS1704 |
| |200 deg.C (392 deg.F)| | | |
| HX |MULTIWIRE | PTFE | |ABS1527 |
| |260 deg.C (500 deg.F)| 1 DR16 | | |
| |UV laser marking |+3 DR18 | | |
| | |+6 DR20 | | |
| | |+8 DR24 | | |
| HY |MULTIWIRE | PTFE | |ABS1529 |
| |260 deg.C (500 deg.F)| 1 DR18 | | |
| |UV laser marking |+5 DR24 | | |
| | |+2 MLB24 | | |
-------------------------------------------------------------------------------
TABLE 1-K
-------------------------------------------------------------------------------
| Quad Cable Identification Coding |
|-----------------------------------------------------------------------------|
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
-------------------------------------------------------------------------------
| KB | Quadrax for digital | FEP | | ABS0972* |
| | transmission | | | |
| |125 deg.C (257 deg.F)| | | |
| KD | Quadrax | FEP | | ABS1503 |
| |125 deg.C (257 deg.F)| | | |
| KG | Twinax | PTFE - FEP | | EN3375-003|
| |200 deg.C (392 deg.F)| | | |
|-----------------------------------------------------------------------------|
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
|-------|---------------------|-------------------|---------------|-----------|
| SE | 600V-260 C (500 F) | KAPTON/PTFE | AIR 4524 |NSA935171 |
| SF | 600V-200 C (392 F) | KAPTON-FEP SHEATH | AIR 4524 |NSA935172 |
|SFA/SFB| 600V-200 C (392 F) | KAPTON-FEP SHEATH | |NSA935172 |
| SG | 600V-200 C (392 F) | PTFE/KAPTON/ | |NSA935173 |
| | | FEP 130pF/m | | |
| SJ | 600V-200 C (392 F) | 1 CF | | E0270 |
| | Ink jet marking | | | |
| | SJ-C | PI | | E0270 |
| | CO2 laser marking | | | |
| | SJ-U | PI | | E0270 |
| | UV laser marking | | | |
| | SJ-Y | PI | | E0270 |
| | YAG-X3 laser marking| | | |
| ST | 600V-260 C (500 F) | 1 DK | | E0271 |
| | Ink jet marking | KAPTON/PTFE | | |
| | ST-C | | | E0271 |
| | CO2 laser marking | | | |
| | ST-U | | | E0271 |
| | UV laser marking | | | |
| | ST-Y | | | E0271 |
| | YAG-X3 laser marking| | | |
| SW | 600V-200 C (392 F) | KAPTON-PTFE | | E0291 |
| | | FEP 130pF/m | | |
| SX | 600V-180 C (356 F) | XL-ETFE | | ABS0823 |
| | (Landing gear only) | | | |
-------------------------------------------------------------------------------
TABLE 1-T
-------------------------------------------------------------------------------
| Cable Identification Coding |
| Pair Twisted, Shielded and Insulated |
|-----------------------------------------------------------------------------|
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
|-------|---------------------|-------------------|---------------|-----------|
| TC | 600V-180 C (356 F) | XL-ETFE | | ABS0824 |
| | (landing gear only) | | | |
| TG | 600V-260 C (500 F) | KAPTON-PTFE | AIR 4524 |NSA935211/ |
| | | KAPTON SHEATH | |213 |
| TJ | 600V-150 C (302 F) | KAPTON-FEP SHEATH | AIR 4524 |NSA935212 |
|TJA/TJB| 600V-200 C (392 F) | 2 AKA/AKB | |NSA935214 |
| | | KAPTON-FEP SHEATH | | |
| TK | 600V-200 C (392 F) | 2 CF | | E0272 |
| | Ink jet marking | KAPTON-FEP | | |
| | TK-B | | | E0272 |
| | UV laser marking | | | |
| | TK-C | | | E0272 |
| | CO2 laser marking | | | |
| | TK-U | | | E0272 |
| | UV laser marking | | | |
| | TK-Y | | | E0272 |
| | YAG-X3 laser marking| | | |
| TT | 600V-260 C (500 F) | 2 DK | | E0273 |
| | Ink jet marking | PI-PTFE | | |
| | TT-C | | | E0273 |
| | CO2 laser marking | | | |
| | TT-U | | | E0273 |
| | UV laser marking | | | |
| | TT-Y | | | E0273 |
| | YAG-X3 laser marking| | | |
-------------------------------------------------------------------------------
TABLE 1-U
-------------------------------------------------------------------------------
| Cable Identification Coding |
| Three Twisted, Shielded and Insulated |
|-----------------------------------------------------------------------------|
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
|-------|---------------------|-------------------|---------------|-----------|
| UC |180 deg.C (356 deg.F)| XL-ETFE | | ABS0825 |
| | (Landing gear only) | | | |
| UD | 600V-200 C (392 F) | 3 CF | | E0274 |
| | Ink jet marking | KAPTON-FEP | | |
| | UD-B | | | E0274 |
| | UV laser marking | | | |
| | UD-C | | | E0274 |
| | CO2 laser marking | | | |
| | UD-U | | | E0274 |
| | UV laser marking | | | |
| | UD-Y | | | E0274 |
| | YAG-X3 laser marking| | | |
| UE | 600V-260 C (500 F) | 3 DK | | E0275 |
| | Ink jet marking | KAPTON-PTFE | | |
| | UE-C | | | E0275 |
| | CO2 laser marking | | | |
| | UE-U | | | E0275 |
| | UV laser marking | | | |
| | UE-Y | PI/FEP | | E0275 |
| | YAG-X3 laser marking| | | |
| UG | 600V-260 C (500 F) | KAPTON-PTFE | AIR 4524 |NSA935251/ |
| | | KAPTON SHEATH | |254 |
| UK | 600V-150 C (302 F) | KAPTON-FEP SHEATH | AIR 4524 |NSA935252 |
| | | | |/253 |
|UKA/UKB| 600V-200 C (392 F) | 3 AKA/AKB | |NSA935252 |
| | | KAPTON-FEP SHEATH | |/253 |
| UU | 600V-260 C (500 F) | PTFE/PI | |EN2714-011C|
-------------------------------------------------------------------------------
TABLE 1-V
-------------------------------------------------------------------------------
| Cable Identification Coding |
| Four and Five Twisted, Shielded and Insulated |
|-----------------------------------------------------------------------------|
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
|-------|---------------------|-------------------|---------------|-----------|
| VH | 600V-260 C (500 F) | PI/PTFE | | ABS0311 |
| VJ | 600V-260 C (500 F) | PI/PTFE | | ABS0323 |
| VM | 600V-260 C (500 F) | PI/PTFE | |EN2714-003D|
| VNA |180 deg.C (356 deg.F)| 1 AD | | ABS1356 |
| | UV laser marking | Single-core | | |
| VNB |180 deg.C (356 deg.F)| 2 VNA | | ABS1356 |
| | UV laser marking | | | |
| VNC |180 deg.C (356 deg.F)| 3 VNA | | ABS1356 |
| | UV laser marking | | | |
| VND |180 deg.C (356 deg.F)| 4 VNA | | ABS1356 |
| | UV laser marking | | | |
| VR | 600V-260 C (500 F) | KAPTON/PTFE 5 DK | 462205/84 | ABS0124 |
| VV | 600V-260 C (500 F) | PI/PTFE 4 DMA | |EN2714-011D|
-------------------------------------------------------------------------------
TABLE 1-W
-------------------------------------------------------------------------------
| Coaxial Cable Identification Coding |
|-----------------------------------------------------------------------------|
| WIRE | TYPE | INSULATOR | SPECIFICATION | STANDARD |
| TYPE | | | | P/N |
| CODE | | | | |
|------|---------------------|-------------------|----------------|-----------|
| WA | COAXIAL | POLYIMIDE-PTFE | |NSA935358 |
| |200 deg.C (392 deg.F)| | | |
| WB | COAXIAL | POLYIMIDE-PTFE | |NSA935359 |
| |200 deg.C (392 deg.F)| | | |
| WC | TRIAXIAL | PTFE | | E0349 |
| |200 deg.C (392 deg.F)| | | |
| WD | DOUBLE SHIELD | FEP | | E0406 |
| |200 deg.C (392 deg.F)| | | |
| WF | TWINAX | KAPTON-FEP | | ABS0386 |
| |200 deg.C (392 deg.F)| | | |
| WJ | TWINAX | PTFE-FEP | |EN3375-004 |
| |200 deg.C (392 deg.F)| | | |
| WQ | COAXIAL | PTFE-FEP | MIL-C-17D | ABS0710 |
| |200 deg.C (392 deg.F)| | | |
| WR | DOUBLE SHIELD COAX | PTFE-FEP | | E0738 |
| |200 deg.C (392 deg.F)| | | |
| WX | COAXIAL-200 C(392 F)| 2 CF | | E0807 |
| |200 deg.C (392 deg.F)| | | |
| WZ | COAXIAL-200 C(392 F)| FEP | |EN4604-003 |
NOTE: YY is the AWM/AWL code of a wire that is a vendor sub-assembly of an equipment and whose type could be given by the CMM of the equipment.
5. Gauges
The table that follows gives the list of wire gauges and the related sections.
----------------------------------------------------------------------
| | EN | |
| AWG | WIRE | REAL SECTION |
| GAUGE | GAUGE |--------------------------------------------|
| | CODE | IN mm2 | IN IN2 |
|-----------|-----------|----------------------|---------------------|
| 26 | 001 | 0.15 | 0.2 x 10-3 |
| 24 | 002 | 0.25 | 0.3 x 10-3 |
| 22 | 004 | 0.40 | 0.5 x 10-3 |
| 20 | 006 | 0.60 | 0.9 x 10-3 |
| 18 | 010 | 1.00 | 1.5 x 10-3 |
| 16 | 012 | 1.20 | 2 x 10-3 |
| 14 | 020 | 2.00 | 3 x 10-3 |
| 12 | 030 | 3.00 | 4 x 10-3 |
| 10 | 050 | 5.00 | 7 x 10-3 |
NOTE: On the electrical drawings only, the large gauges have a special codification.
---------------------------------
| DRAWING GAUGE | AWG GAUGE |
|-----------------|-------------|
| 100 | 0 |
| 200 | 00 |
| 300 | 000 |
| 400 | 0000 |
---------------------------------
6. Manufacturer Identification
A. Identification by Printing of External Sheaths
This identification has a series of figures printed horizontally.
If the wire external diameter is less then 1.27 mm (0.0500 in.) , vertical printing is permitted.
(1) United States (US) wire types :
Printing (as per SPEC 451242/78) with a pitch of 300 mm (11.8110 in.) plus or minus 50 mm (1.9685 in.) pitch along the whole length of the wire. It must be of the type :
AA-BB-C-22
Example : AKA - FF - L - 20
The code consists of 4 groups of letters or figures. The groups are separated by a dash or a space.
Group 1 : Two or three letters identify the wire type code (Ref. tables 1-A to 1-Y).
e.g. AKA
Group 2 : Two letters identify the manufacturer and the country (Ref. table 2). e.g. FF (FILOTEX/FRANCE).
Group 3 : One or two letters indicate the year of manufacture (Ref. table 3).
e.g. L (1973)
Group 4 : Wire gauge.
e.g. 20
Example :
AKA - FF - L - 20
| | | |------- Wire Gauge
Wire Type Code | | |
Wire per NSA935012 -----| | |------------ Year of Manufacture (1973)
|---------------- Country and Manufacturer Code
( FRANCE - FILOTEX )
(2) Metric (M) wire types :
(a) ASN/NSA Standard P/Ns
Group 3 : One letter indicates the coating code for laser marking (Ref. table 4).
e.g. C (FEP)
Group 4 : Two letters identify the country of manufacture (Ref. table 2).
e.g. FR (FRANCE)
Group 5 : One letter identifies the manufacturer (Ref. table 2).
e.g. A (FILECA)
Group 6 : Two numbers indicate the year of manufacture (Ref. table 3).
e.g. 91 (1991)
Example (FROM 1991) :
CF 24 C FR A 91
Wire Type Code | | | | | |
Wire per E0261 -----| | | | | |----------- Year of manufacture
Wire Gauge --------| | | |-------------- Manufacturer Code
| |----------------- Country of manufacture
Coating code --------------|
(Ref. table 4)
(b) EN Standard P/Ns
- UP TO 1998:
Example:
EN2266-005 A 002 P FR A 98
----- -- -- - -- - --
| | | | | | |-----
Manufacture Year Code
| | | | | | (Ref. table 3)
| | | | | |---------
Manufacturer Code (Ref. table 2)
| | | | |--------------
Country of Manufacture
| | | | (Ref. table 2)
| | | |------------------
Core insulator color code
(Ref. table 7 and 8)
| | | ---------------------- Wire gauge code
| | ---------------------------- Code letter for number of cores
| (Ref. table 9)
|-------------------------------------- Standard P/N
- FROM TO 1998:
Example:
EN CF U 24 FR A 98
-- -- - -- -- - --
| | | | | | |----- Manufacture Year Code (Ref. table 3)
| | | | | |--------- Manufacturer Code (Ref. table 2)
| | | | |-------------- Country of Manufacture (Ref. table 2)
| | | |------------------ AWG Wire gauge
| | |----------------------- Specific Code (Ref. tables 1-A to 1-Y)
| |---------------------------- Wire type code (Ref. tables 1-A to 1-Y)
|
|--------------------------------- Reference to EN Standard wire
(c) Fiberglass cable
Example:
LF XXX 00
-- --- -
| | |---- Manufacture Year Code
| |--------- Manufacturer and country of manufacture codes
Printing of composition element reference and its color on each element (e.g. : CF20X-FA-A).
Element color as per para. 6.
(c) Shielded single-core cables :
- Printing of element reference on the element.
Mandatory printing of the assembly reference on external sheath.
- For laser printed cable, marking only on the external sheath.
Marking on the element is optional.
(d) Shielded multi-core cables :
- Printing of element reference on each element.
Optional printing of the assembly reference on the external sheath except indications on specific sheets. Each marking is linked by a dashed line.
- For laser printed cable, marking only of the external sheath.
Marking on the element is optional.
Element color as per para. 6.
(3) Coaxial Cables
Printing on external sleeve must be white, green or black.
- SOLUTION 1 :
Example 1 (up to 1986) :
WD AA F A
| | | |
| | | ----- Manufacturer code (Ref. table 2)
Wire Type code | | |
| ----------- Country code (Ref. table 2)
------------------ Manufacturing year code (Ref. table 3)
Example 2 (From 1987 to 1990) :
WD AB FR A
| | | |
| | | ----- Manufacturer code (Ref. table 2)
Wire Type code | | |
| ----------- Country code (Ref. table 2)
------------------ Manufacturing year code (Ref. table 3)
Example 3 (From 1991) :
WD FR A 91
| | | |
| | | ----- Manufacturing year code (Ref. table 3)
Wire type code | | |
| ----------- Manufacturer code (Ref. table 2)
------------------ Country code (Ref. table 2)
- SOLUTION 2 :
MIL Marking code :
e.g. : RG400/U, manufacturing year code, country or manufacturer.
7. TABLE 7 - Single-Core Cable - Insulation Color Code
A. As per MIL.STD.681B
-------------------------------------------------------------------------------
| COLOR | INSULATION COLOR |
| CODE | |
|-----------|-----------------------------------------------------------------|
| 0 | Black |
|-----------|-----------------------------------------------------------------|
| 1 | Brown |
|-----------|-----------------------------------------------------------------|
| 2 | Red (as per FEDERAL STANDARD 595a Ref. 31302) |
|-----------|-----------------------------------------------------------------|
| 3 | Orange (as per FEDERAL STANDARD 595a Ref. 22510) |
|-----------|-----------------------------------------------------------------|
| 4 | Yellow (as per FEDERAL STANDARD 595a Ref. 23655) |
|-----------|-----------------------------------------------------------------|
| | Light green | Reserved for gauge 22 |
| | | (as per FEDERAL STANDARD 595a |
| | | Ref. 24585, 24664, 24670, 24672) |
| 5 |----------------|------------------------------------------------|
| | Dark green | For other gauges and sheath |
| | |(equivalent to FEDERAL STANDARD 595a Ref. 34108)|
|-----------|-----------------------------------------------------------------|
| 6 | Light blue (as per FEDERAL STANDARD 595a Ref. 35488) |
|-----------|-----------------------------------------------------------------|
| 7 | Violet |
|-----------|-----------------------------------------------------------------|
| 8 | Grey |
|-----------|-----------------------------------------------------------------|
| 9 | White |
-------------------------------------------------------------------------------
B. As per EN (Only for Single-Core Cables)
---------------------------- ----------------------------
| COLOR | INSULATION | | COLOR | INSULATION |
| CODE | COLOR | | CODE | COLOR |
|-----------|--------------| |-----------|--------------|
| A | Red | | H | Orange |
|-----------|--------------| |-----------|--------------|
| B | Blue | | J | Purple |
|-----------|--------------| |-----------|--------------|
| C | Yellow | | K | Violet ** |
|-----------|--------------| |-----------|--------------|
| D | Green | | L | Light Red ** |
|-----------|--------------| |-----------|--------------|
| E | White | | P | * |
|-----------|--------------| |-----------|--------------|
| F | Black | | Q | * |
|-----------|--------------| |-----------|--------------|
| G | Brown | | R | * |
---------------------------- |---------------------------
| S | * |
----------------------------
** The color can be different depending of the wire type.
* For these codes the color depends on the cable size code :
-------------------------------------------------------------------
| CABLE | COLOR CODE |
| SIZE |-------------------------------------------------------|
| CODE | P | Q | R | S |
|---------|-------------|-------------|-------------|-------------|
| 001 | White | Pink | White | Light green |
|---------|-------------|-------------|-------------|-------------|
| 002 | White | White | Light blue | White |
|---------|-------------|-------------|-------------|-------------|
| 004 | Light green | Light green | White | Light green |
|---------|-------------|-------------|-------------|-------------|
| 006 | White | Pink | Light green | White |
|---------|-------------|-------------|-------------|-------------|
| 010 | White | White | White | White |
|---------|-------------|-------------|-------------|-------------|
| 012 | White | Light green | Light blue | White |
|---------|-------------|-------------|-------------|-------------|
| 020 | White | Pink | White | White |
|---------|-------------|-------------|-------------|-------------|
| 030 | White | White | White | White |
|---------|-------------|-------------|-------------|-------------|
| 050 | White | Light green | White | White |
|---------|-------------|-------------|-------------|-------------|
| 051 | White | Light green | White | White |
|---------|-------------|-------------|-------------|-------------|
| 090 | White | - | White | White |
|---------|-------------|-------------|-------------|-------------|
| 140 | White | - | White | White |
|---------|-------------|-------------|-------------|-------------|
| 220 | White | - | White | White |
|---------|-------------|-------------|-------------|-------------|
| 340 | White | - | White | White |
-------------------------------------------------------------------
8. TABLE 8 - Multi-Cores Cables - Insulation Color Code (only for EN P/Ns)
The tables that follow give the insulation color code for the cables and the insulation color for the core(s) in relation to the number of cores in the cable.
To find the insulation color code of a cable :
- Refer to the insulation color code allocation table to find the possible insulation color codes depending on the EN P/N.
- Find the color code depending on the number and the color of the cores in the cable.
A. Insulation Color Code Allocation Table and Insulation Color Code A
(Ref. Fig. 001)
B. Insulation Color Code B or C
(Ref. Fig. 002)
C. Insulation Color Code D or Q
(Ref. Fig. 003)
D. Insulation Color Code F, G or P
(Ref. Fig. 004)
E. Insulation Color Code H, J or R
(Ref. Fig. 005)
Figure 001.1 / Graphic SH 001.1 Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Insulation Color Code Allocation Table and Insulation Color Code A
Figure 002.1 / Graphic SH 002.1 Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code B and C (for EN P/Ns)
Figure 003.1 / Graphic SH 003.1 Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code D and Q (for EN P/Ns)
Figure 004.1 / Graphic SH 004.1 Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code F, G or P (for EN P/Ns)
Figure 005.1 / Graphic SH 005.1 Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code H, J or R (for EN P/Ns)
Figure 006.1 / Graphic SH 006.1 Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code For EN2346 and EN4608 P/Ns
GY Grey
O Orange
P Purple
PK Pink
R Red
V Violet
W White
Y Yellow
NOTE: The code N is obsolete for cables. When you see this on a cable it is the some as BK.
3. Cable Number
All cables connected on the aircraft must be identified. It is the functional identification of the cable.
NOTE: If necessary, one more figure is added after these two groups to identify the color of the cable.
If necessary, one more figure is added (letter "S") to identify the safety cable.
NOTE: Some cables have the FIN 0000-000X. These cables do not have an electrical function. They are used to increase the diameter of the harness to which they belong.
2314 - 9904 R
2792 - 0162 B S
---- ---- - -
| | | |
| | | ----- S = safety cable code (if necessary)
| | |
| | -------- Wire color code (if necessary)
| |
| -------------- No. of the cable in the circuit
|
--------------------- No. of the circuit defined by ATA Spec 100
B. Cable Marking
Cable marking procedures depend on the category of the cables.
There are three main categories of cable:
- Printable cables.
- Non-printable cables.
- Cables without marking.
(1) Printable cables
(Ref. Fig. 001)
(a) Definition
Printable cables are identified by direct marking of the identification on the insulation, at regular intervals.
NOTE: You must install identification sleeves on branches and junctions (only if branch and junction lengths are more than
1 m (3.28 ft.) ).
NOTE: If the harness has no branches, you must attach a VB marking to the harness at intervals of
2 m (6.56 ft.) . This is not applicable if the harness is supplied in raceways or if other interval values are specified in the design document.
(b) Operation
Cables are identified with sleeves NSA937201.
-------------------------------------------------------------
NOTE: When a safety cable is in aluminum, the sleeve must be pink and printed in black.
1 Single-core cables
(Ref. Fig. 002)
- These cables are identified with sleeves NSA 937201 ME.
- Sleeve length must be between
25 mm (0.9842 in.) and 35 mm (1.3779 in.) .
2 Sheathed multi-core cables (cores of different colors)
(Ref. Fig. 003)
a The multi-core cable and the cores have different identification markings (only A300 / A300-600 / A310).
The cable will have one (or several) sleeve at each end with the information below:
- the identification of each cable with its color code,
- the identification of the assembly (the multi-core cable).
b The multi-core cable and the cores have the same identification marking (A320 to A380 family).
The color code is used to connect the cables (cables of the same color).
3 Sheathed multi-core cables (cores of same color)
(Ref. Fig. 002)
(only A300 / A300-600 / A310)
Each cable has an identification number.
If the cable is shielded, the shield will also have an identification sleeve.
4 Twisted cables without sheath
(Ref. Fig. 002)
NOTE: You can use sleeves to identify the optical cable, because they are easy to make. If you use a shrink sleeve, do not shrink it after installation.
NOTE: A specific label ABS0724 or NSA931025 is installed adjacent to the optical connectors to show the special precautions related to this type of connector.
NOTE: You must not use cable ties to attach the label. This can cause damage to the cable.
NOTE: For labels and sleeves, all colors are permitted except pink and red.
The number of repairs on a coaxial cable is identified adjacent to the end component with:
- E0248 label or equivalent,
- E0683 self-adhesive label or equivalent.
If the above labels are not available, you can use NSA937201 sleeve or equivalent (not shrunk).
(7) Cables without markings
- Very short cables shorter than
75 mm (2.9527 in.) and ground pick-up cables (ferrule-to- ferrule or to connector) are not identified.
- Cables used for circuit breaker monitoring (only for A320 program),
- Monitoring cables between two adjacent "in-line" circuit breakers (only for A330, A340 and A380),
- Cables in small VUs (BF type - flexible cables) are not printable.
- Bonding cables shorter than
300 mm (11.8110 in.) .
Figure 001.1 / Graphic SH 001.1 Cable Functional Identification - Example for Printable Cables
Figure 002.1 / Graphic SH 002.1 Cable Functional Identification - Example for Non-Printable Cables
Figure 003.1 / Graphic SH 003.1 Cable Functional Identification - Example for Non-Printable Cables
Figure 004.1 / Graphic SH 004.1 Cable Functional Identification - Specific Identification Marking
(1) Harness
A harness is a group of cables attached together.
All cables are identified (Ref. chapter 20-32-22).
A vendor or the airframe manufacturer can supply some harnesses (for example in some radio or fuel systems). Such harnesses will have a FIN and will be identified as all other components.
If supplied by a vendor (code YY), it will have a part number.
If made by the airframe manufacturer, it will have a drawing number.
Only the graphic symbol on the wiring diagram will identify the difference between two such cases.
(2) Wiring segregations or routes
For safety and to prevent possible interference, electrical harnesses are routed in relation to their type and function in a number of physically isolated routes. These wiring segregations or routes are divided into categories related to
the aircraft type.
A 2-digit reference is used to identify these categories (Ref. chapter 20-33-20).
2. Harness identification
A. Principle
Flags and labels on harnesses give many types of data:
- Positioning data such as the frame:
These positioning flags give harness pick-up points for correct installation of the harness on the aircraft.
- Functional data (routes, sub-routes):
These functional identification labels must show the routes in the harness and be in a position to prevent all risks of errors caused by in-service retrofit work.
- Functional Item Number (FIN) identification at harness end:
You must identify harness ends with E0248A labels (4 holes) where the identification of the end is shown.
For typical harnesses, these labels are white with black printing and are attached with two cable ties NSA935401.
NOTE: In severe environment areas, you must use and attach labels E0248A (6 holes) with three cable ties NSA935401.
NOTE: Positioning flags must stay in position on the aircraft and not be moved from their initial position.
NOTE: Labels for route identification can be bonded on the structure (frame).
NOTE: Positioning flags must stay in position on the aircraft and not be moved from their initial position.
NOTE: If, adjacent to the last clamp, the last identification is with a white label E0248, label ASNA5107 is only used to increase the mechanical protection of the harness below the clamp and the positioning flag.
NOTE: As an alternative, you can use a sleeve (e.g. NSA937201ME) but you must not shrink it.
NOTE: A special label ABS0724 or NSA931025 is installed adjacent to the optical connectors to show special precautions related to this type of connector.
Figure 001.1 / Graphic SH 001.1 Harness Functional Identification - Example of Identification on Harness
Figure 002.1 / Graphic SH 002.1 Harness Functional Identification - Example of Marking on Harnesses
Figure 003.1 / Graphic SH 003.1 Harness Functional Identification - Identification with E0683 Description and Installation (for A318/A319/A320/A321 only)
Figure 004.1 / Graphic SH 004.1 Harness Functional Identification - Positioning and Identification with E0248 Description and Installation (for A330/A340 and A380 only)
Figure 005.1 / Graphic SH 005.1 Harness Functional Identification - Flag Installation on Optical Cables
NOTE: Boxes, panels or equipment containing parts with voltages exceeding 42 V which are liable to expose maintenance personnel to hazardous operations must have a label reading: "CAUTION HIGH VOLTAGE INSIDE". This label must
have
6 mm (0.2362 in.) white letters on a red background.
NOTE: Identical components which have the same function in the same circuit are differentiated by a suffix number.
The general rule is that an even suffix identifies a component on the right-hand side and an odd suffix identifies a component on the left-hand side.
Example: 14CA1
Example: nnnnVBnnn
- The 1st, 2nd, 3rd and 4th numerical digits indicate the partner allocation number.
- The two-letter code indicates the fictitious circuit (V) and the type of component.
- The last three numbers indicate the multiple elements of the component. (It is possible to use only one number)
(c) For circuit VU, the FIN format consists of 7 to 9 digits:
Example: 1115VU1
- The 1st and 2nd numerical digits indicate the partner allocation number.
- The 3rd and 4th numerical digits (00) indicate a main assembly containing sub-assemblies.
- For the 4th digit:
An odd number indicates the left side. (Except 5)
An even number indicates the right side.
Number "5" indicates a panel located on the aircraft centerline.
- The two-letter code indicates the fictitious circuit (V) and the type of component (U).
- The last three numbers indicate the multiple elements of the component. (It is possible to use only one number)
B. Fictitious Circuit (letter V)
Fictitious circuits (letter V) are allocated to types of components that cannot be identified as part of a specific system circuit.
(1) The codes of these fictitious circuits are:
VB = Cable bundle/harness
VC = Connector (appended letter A, B, etc. is added to identify the free connector: E.g. 1204VC A)
NOTE: For A380, there is no space or dash before the appended letter.
- The EFCS harnesses and the different VU panels to which they are connected.
The EFCS harnesses and equipment are clearly identified by a pink or red mark.
Identification of each item is made by a permanent label that shows the functional item number. (FIN)
3. Electrical Items Functional-Identification Marking
(Ref. Fig. 001)
(Ref. Fig. 002)
(Ref. Fig. 003)
(Ref. Fig. 004)
The ways to mark the items depend on the item categories and location.
There are three ways to mark:
- Self-adhesive label (ABS0724, E0470, E0683 or NSA931025).
- Identification Sleeve (E0646, NSA937201 or NSA937203).
The functional identification of equipment may be given on white sleeves when it is difficult to install labels near the equipment.
These sleeves must be positioned immediately after the identification of the connector, or include this identification.
Functional identification sleeves must be fitted where equipment is removable from its front face.
- Identification label (ABS1475 or E0248) with NSA935401 (TY-RAP type).
NOTE: If reading of the label proves to be difficult during the maintenance operation, or in case of ambiguity, a second label that shows the type of equipment as indicated on the wiring diagram will also be added to the loom.
The ways to mark must be designed taking into account temperature ranges and environmental constraints.
NOTE: In non-pressurized area, it is necessary to bond label with material number 09-008C and to apply varnish material number 07-018 to the label.
Bond a self-adhesive label to the support near the ground module or point.
(d) Stud-type or modular terminal blocks (VT)
The terminal blocks are identified by a label fixed to the support, near the rail.
(e) Miscellaneous equipment
On circuit breakers or coded equipment items directly connected on aircraft, etc. install a self-adhesive label on the support near the equipment.
NOTE: Relays with the spike suppression function must be identified with an additional blue mark on the structure adjacent to the FIN label.
(f) Relays
1 On A380:
- Use identification label ABS0724-006A013 for Normal relays on Normal system. (Label has white background with black letters)
- Use identification label ABS0724-006P013 for Normal relays on EFCS system. (Label has pink background with black letters)
- Use identification label ABS0724-006B013 for spike suppression relay on Normal system. (Label has blue background with black letters)
- Use identification label ABS0724-006 for spike suppressioN relay on EFCS system. (Label has blue and pink background with black letters)
(g) Specific Items
All specific EFCS equipment items (connectors, terminal blocks, relays) are identified clearly and permanently with a pink or red adhesive label (E0248) bonded to the structure near each item.
B. Item Identification on Cable Bundles
(Ref. Fig. 005)
(Ref. Fig. 006)
(1) Marking type
Bundles of items are identified:
- For cables subjected to temperatures above
150 deg.C (302.00 deg.F) , with E0248 labels and NSA935401 cable-tie (TY-RAP type).
- For wiring subjected to temperatures above
260 deg.C (500.00 deg.F) , with NSA937201 sleeves.
This identification sleeve or label has:
- In all cases, the FIN of the item.
- When the bundle ends in a VU, the VU number.
- And if necessary, the functional designation.
- On harness with diameter less than
5 mm (0.1968 in.) , the identification label must be replaced by a sleeve NSA937201.
NOTE: In vibration areas or in Severe Weather and Moisture Prone (SWAMP) areas, you must use a label E0248 16HP (6 holes) with three tie-wrap NSA935401.
NOTE: It is necessary to shrink the sleeves in electrical power centers or in areas that have severe environnemental conditions.
NOTE: Identification sleeves must be in a position as near as possible to the connection you must identify (max. distance
100 mm (3.9370 in.) ). If necessary, you can attach these sleeves with cable ties to prevent sliding.
NOTE: Identification sleeves can be shrunk. In this case, it must still be possible to turn, slide and read them.
(2) Operation
These types of marking are made of plastic.
They are white for standard bundles or pink for the bundles of EFCS items, with FIN marking in black.
They are installed on the cable bundle at 130 mm (5.1181 in.) maximum from the end.
If the harness has no branch, you must attach a VB marking to the harness at intervals of 2 m (6.56 ft.) . This is not applicable if the harness is supplied in raceways and if other interval values are specified in the design documents.
Labels are not necessary on branches shorter than 1 m (3.28 ft.) .
Their position on the bundle will make correct reading possible when the bundle terminations are connected.
Safety cables are identified by a pink colored sleeve or with the letter "S" printed at the end of the P/N. (E.g.: 3151-0309S)
NOTE: When segregation is required, the identification is installed on one bundle and does not include the other routes.
Install an identification label E0248 on the ARINC 600 and 404A connectors (ABS0831, E0161, E0163, E0165, E0086, E0145, E0147, E0726 and E0729 ) or derived connectors.
(b) Optical connectors
(Ref. Fig. 007)
- A specific label ABS0724 or NSA931025 is installed near the optical connectors to indicate particular precautions related to this type of connector.
NOTE: You must use lacing tape NSA8420 to attach the identification labels. The use of NSA935401 is not permitted to prevent damage to optical fiber harnesses.
NOTE: To make installation of the identification easier, the use of a sleeve is permitted. If you use a shrink sleeve, you must not shrink it to prevent damage.
NOTE: If the splice is inside a split textile conduit, the identification label must be over the split textile conduit.
3 Reducing splices
No identification sleeve.
(f) Diode
A diode is identified by a sleeve NSA935201, on the cable, positioned alongside the diode.
(g) Pressure Seal (VP)
The pressure seals through which the cable bundle is routed are identified by two E0248 labels with NSA935401 (TY-RAP type), one on each side of the seal.
(h) Coded equipment items directly connected on aircraft
With or without cut-to-length: Install a label E0248.
(i) Specific items
All specific EFCS equipment items (connectors, terminal blocks, relays, circuit-breakers) are clearly and permanently identified with pink or red labels (E0248) printed in black, which are indelible and clearly visible and bonded to
the structure near the items.
(j) Shielding continuity connection
CAUTION: DO NOT USE METAL LABELS IN BOXES THAT CONTAIN ELECTRICAL ITEMS AND WIRING. IF THERE IS CHAFING OF THE CABLE INSULATION OR THE ELECTRICAL COMPONENTS, SUCH LABELS CAN
CAUSE SHORT CIRCUITS.
NOTE: A large VU is an electrical assembly consisting only of CF/DM/DR-type cables where the radius of curvature is equal to 6xD.
A small VU is an electrical assembly consisting mainly of BF-type cables with low radius of curvature equal to 3xD.
The electrical boxes have a label E0470 with the VU identification Number and a label NSA931025 with the Aircraft Number (MSN)
(2) Small VUs
In small VUs, the cables (BF or CF type) have the sleeve E0646MF (EX NSA937204 MF) marked with the identification of the connection terminal of the related end.
But this type of sleeve is not used for the items below:
- Cut-off receptacle (VC)
- Modular terminal blocks (VT)
- Ground point (VN)
- Illuminated VU plugs (LF)
- Diode module (VD)
Figure 001.1 / Graphic SH 001.1 Electrical Item Functional-Identification - Marking Types E0248, E0470, E0646 (ex NSA937204), NSA937201, NSA937203
Figure 002.1 / Graphic SH 002.1 Electrical Items Functional Identification - Unplugged ventilation holes
Figure 006.1 / Graphic SH 006.1 Electrical Item Functional Identification - Examples of Marking on Harnesses
Figure 008.1 / Graphic SH 008.1 Electrical Item Functional-Identification - Example of Marking in Small VUs
A B C D F G H J P Q R
EN2267 X X X
EN2714 X X X X X X X X
1 WHITE
2 WHITE BLUE
L_ES_203221_0_AAM0_01_01
Figure 001 (Sheet 1) / 20-32-21 - Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Insulation Color Code Allocation Table and Insulation Color Code A
FOR INSULATION COLOR CODE B: CABLE INSULATION IS LIGHT BLUE FOR WIRE GAUGE
CODES 002/006/012
CABLE INSULATION IS WHITE FOR OTHER WIRE GAUGE CODES
FOR INSULATION COLOR CODE C: CABLE INSULATION IS WHITE WHATEVER THE WIRE GAUGE CODE.
1 WHITE
2 WHITE BLUE
3 WHITE BLUE ORANGE
WHITE BLUE ORANGE GREEN
WHITE BLUE ORANGE GREEN RED
WHITE BLUE ORANGE GREEN RED BLACK
WHITE BLUE ORANGE GREEN RED BLACK YELLOW
WHITE BLUE ORANGE GREEN RED BLACK YELLOW VIOLET
WHITE BLUE ORANGE GREEN RED BLACK YELLOW VIOLET GREY
10 WHITE BLUE ORANGE GREEN RED BLACK YELLOW VIOLET GREY BROWN
L_ES_203221_0_A DM0_01_01
Figure 002 (Sheet 1) / 20-32-21 - Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code B and C (for EN P/Ns)
12mm TO 17mm
2 nd
1.5mm TO 3mm
12mm TO 17mm
3 rd
3.5m m TO 5mm
12mm TO 17mm
4 th
12mm TO 17mm
8 th
3m m TO 6mm 3.5m m TO 5mm
Figure 003 (Sheet 1) / 20-32-21 - Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code D and Q (for EN P/Ns)
FOR INSULATION COLOR CODE F: CABLE INSULATION IS LIGHT BLUE FOR WIRE GAUGE CODES 002/006/012.
CABLE INSULATION IS WHITE FOR OTHER WIRE GAUGE CODES.
FOR INSULATION COLOR CODE G: CABLE INSULATION IS WHITE WHATEVER THE WIRE GAUGE CODE.
FOR INSULATION COLOR CODE P: CABLE INSULATION IS LIGHT BLUE FOR WIRE
GAUGE CODES 002/006/012.
CABLE INSULATION IS WHITE FOR OTHER WIRE
GAUGE CODES.
NUMBER OF CORES
COLORS
IN CABLE
1 WHITE *
2 RED BLUE
3 RED BLUE YELLOW
RED BLUE YELLOW GREEN
RED BLUE YELLOW GREEN WHITE
RED BLUE YELLOW GREEN WHITE BLACK
RED BLUE YELLOW GREEN WHITE BLACK BROWN
RED BLUE YELLOW GREEN WHITE BLACK BROWN ORANGE
RED BLUE YELLOW GREEN WHITE BLACK BROWN ORANGE PURPLE
10 RED BLUE YELLOW GREEN WHITE BLACK BROWN ORANGE PURPLE G R E Y
* FOR CODE F: LIGHT GREEN FOR WIRE GAUGE CODE 004 AND LIGHT YELLOW FOR WIRE
GAUGE CODE 001.
Figure 004 (Sheet 1) / 20-32-21 - Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code F, G or P (for EN P/Ns)
NUMBER OF CORES
IN CABLES COLORS
LIGHT DARK
5 BLACK * YELLOW RED
BLUE GREEN
2 WHITE BLUE
3 WHITE BLUE YELLOW
WHITE BLUE YELLOW GREEN
Figure 005 (Sheet 1) / 20-32-21 - Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code H, J or R (for EN P/Ns)
FOR EN2 346 AND EN4608, THERE IS NO INSULATION COLOR CODE IN THE P/N
IDENTIFICATION. THE TABLE THAT FOLLOWS GIVES THE COLOR OF THE STRIPES
STAMPED ON THE INSULATION OF THE CORES.
1 RED
2 RED BLUE
3 RED BLUE YELLOW
RED BLUE YELLOW GREEN
RED BLUE YELLOW GREEN BLACK
RED BLUE YELLOW GREEN BLACK BROWN
RED BLUE YELLOW GREEN BLACK BROWN ORANGE
RED BLUE YELLOW GREEN BLACK BROWN ORANGE PURPLE
RED BLUE YELLOW GREEN BLACK BROWN ORANGE PURPLE GREY
L_ES_203221_0_APM0_01_01
Figure 006 (Sheet 1) / 20-32-21 - Wires Identification by the Manufacturer - Insulation Color Code Table 8 - Code For EN2346 and EN4608 P/Ns
PITCH 75 mm MAX.
(2.952 in)
NSA937201
OR
NSA937203
OR CABLE
E0646 MARKING
- SPECIFIC CASE: SLEEVE (OR SLEEVING)
4 4 2211 0187
- PRINTABLE CABLES:
HOT STAMP
L_ES_203222_0_AAM0_01_01
Figure 001 (Sheet 1) / 20-32-22 - Cable Functional Identification - Example for Printable Cables
2322 0122
150 mm
(5.91 in) MAX.
2232 0042
2232 0041
RED RED
2322 0025 R
YELLOW OR 2322 0025 YELLOW
0026 Y 0027 B
BLUE BLUE
L_ES _203222_0_ACM0_01_02
Figure 002 (Sheet 1) / 20-32-22 - Cable Functional Identification - Example for Non-Printable Cables
2232 1301 R
OR
RECTO VERSO
OR
OR
NOTE: WHEN THE IDENTIFICATION SLEEVE SIZE IS TOO SMALL, THE IDENTIFICATION WILL BE
MARKED ON SEVERAL SLEEVES.
ONLY FOR A320/A340/A380: (MUL TI-CORE CABLE AND THE PARTS HAVE THE SAME
IDENTIFICATION NUMBER)
RED CORE
YELLOW CORE
Figure 003 (Sheet 1) / 20-32-22 - Cable Functional Identification - Example for Non-Printable Cables
BLACK WHITE
BLACK WHITE
L_ES_203222_0_A MM0_01_02
Figure 004 (Sheet 1) / 20-32-22 - Cable Functional Identification - Specific Identification Marking
PART NUMBER
L9299812500000
CA CODE LB682 / 8125VB VB NUMBER
SER PL1001
WHITE BACKGROUND
SERIAL NUMBER
Figure 001 (Sheet 1) / 20-32-23 - Harness Functional Identification - Example of Identification on Harness
Figure 002 (Sheet 1) / 20-32-23 - Harness Functional Identification - Example of Marking on Harnesses
C10/PL
PRINTED AREA
1S/1SF/1SL
A
PRINTED
IDENTIFICATION LABEL E0683 AREA
A A
POSITION ON HARNESS:
- HARNESSES ROUTED FROM TOP TO BOTTOM OF AIRCRAFT:
REFERENCE AXIS
10 mm
CLAMP
(0.3937 in)
HARNESS
10 mm
MARKER TOWARDS FRONT OF AIRCRAFT (0.3937 in)
FORWARD CLAMP
REFERENCE AXIS
CLAMP
RH SIDE
10 mm
(0.3937 in) L_ES _203223_0_A AM0_01_02
Figure 003 (Sheet 1) / 20-32-23 - Harness Functional Identification - Identification with E0683 Description and Installation (for A318/A319/A320/A321 only)
CABLE TIE
NSA935401 HARNESS
1S/1SF/1S1
POSITION ON HARNESS:
E0248-6 H
40 mm ± 10 m m
CLAMP 1.575 in ± 0.394 in
NSA5516
REFERENCE AXIS
POSITIONING FLAG 10 mm
ABS5342 (BLUE) 0.394 in
10 mm E0 24 8-6H
POSITIONING FLAG
0.394 in
ABS5342 (BLUE)
F35 1S/1SF/1S1
FORWARD *
RH SIDE **
FR35
40 mm ± 10 m m
REFERENCE AXIS
1.575 in ± 0.394 in
Figure 004 (Sheet 1) / 20-32-23 - Harness Functional Identification - Positioning and Identification with E0248 Description and Installation (for A330/A340 and A380 only)
1. CUT A PIECE OF THE TAPE TO A LENGTH RELATED TO THE DIAMETER OF THE OPTICAL CABLES.
10 mm
FOLDING AXIS (0.394 in)
ADHESIVE SIDE
FOLDING AXIS 10 mm
(0.394 in)
10 mm
(0.394 in)
OPTICAL CABLES
4. PUT THE TWO SIDES OF THE TAPE TOGETHER TO BOND IT. TO REMOVE THE TAPE,
PULL THE ENDS OF THE TAPE TO UNBOND THE FLAG.
Figure 005 (Sheet 1) / 20-32-23 - Harness Functional Identification - Flag Installation on Optical Cables
HINGE
DOOR STRUCTURE
SPARE CONDUIT
1M
HARNESS LABEL ABS5342
E0248
CAUTION
RED MARKING
L_ES_203223_0_AJM0_01_03
E0248 LABEL
(WHITE, YELLOW OR PINK COLORED)
E0248
5HA
ITEM
LABEL TIE-WRAP NSA93540 1
TO PRINT
CONDITIONING
SUPPORT
NUMBER OR LETTER
ONE OR TWO CHARACTERS
L_ES_203251_0_AAM0_01_01
Figure 001 (Sheet 1) / 20-32-51 - Electrical Item Functional-Identification - Marking Types E0248, E0470, E0646 (ex NSA937204), NSA937201, NSA937203
IDENTIFICATION OF UNPLUGGED
VENTILATION HOLES
VENTILATION HOLES
IDENTIFICATION LINES
FILLED HOLES
Figure 002 (Sheet 1) / 20-32-51 - Electrical Items Functional Identification - Unplugged ventilation holes
1PU1 2RN4
T R- 1
2RN4.A
1PU1.A ACP-AVNCS
COMPT
IDENTIFICATION OUTSIDE VU
VU
103VU
1660VCA
103VU
ELECTRICAL HARNESS
1XG
SHELF
RACK + EQUIPMENT
1XG 92VU
GPCU
IDENTIFICATION LABEL
END PLATE
(ABS0724 OR ASNE0470)
MODULE
THE EL ECTRICAL COM PONENTS
ARE PLACED ON EITHER SIDE OF
THE END PLATE
FRONT VIEW TOP VIEW
L_ES _203251_0_ARM0_01_00
5 VC- A
IDENTIFICATION SLEEVE
NSA937201
VS1
VS2
E0248 E0248
SPLICE GROUP
DIODE OR SPLICE
VC
OR
VCA
IDENTIFICATION SLEEVE
NSA937201
PANEL
E0248 E0248
ADHESIVE LABELS
(E0470)
ON EACH SIDE OF THE PANEL L_ES _203251_0_ADM0_01_00
Figure 006 (Sheet 1) / 20-32-51 - Electrical Item Functional Identification - Examples of Marking on Harnesses
BLACK WHITE
- FUEL ROUTING:
RED WHITE
L_ES_203251_0_AEM0_01_01
E0470
ADHESIVE LABEL
STAMPED "5HA"
E0646MF
(EX NSA937204MF)
SLEEVES (UNICUT)
E0248 LABEL WITH
NSA935401 CABLE TIE
1
2
5 5HA
10
EQUIPMENT
1
4SX
2
MODULAR
VN VT TERMINAL
VC BLOCK (VT)
PANEL
E0646MF ADHESIVE LABEL
(EX NSA937207MF) E0470
SLEEVES CIRCULAR CONNECTOR (VC)
(UNICUT)
Figure 008 (Sheet 1) / 20-32-51 - Electrical Item Functional-Identification - Example of Marking in Small VUs