ABSTRACT
The objective of this work was to test the impact of coagulant and flocculant at the stage of mechanical wastewater
treatment on the wastewater treatment plant operation, performed in the A2O process. In this paper, the principles
of correct conduct of coagulation in wastewater treatment have been discussed. It appears from the research per-
formed that significant elimination of BOD5 such as 20÷30%, total suspended matter up to 90%, COD up to 50%
and total nitrogen at 30% level was achieved supported by the coagulation process in the pre-settling tanks. Ap-
proximately 50% of phosphorus was eliminated after the mechanical part. Additionally, a significant impact of
Superfloc flocculant on the effectiveness of the solid phase separation (activated sludge) in the secondary settling
tank was noted under diversified flow conditions.
81
Journal of Ecological Engineering Vol. 19(6), 2018
Figure 1. Flow diagram of the biological part in JAMNO Wastewater Treatment Plant
82
Journal of Ecological Engineering Vol. 19(6), 2018
BOD5, total suspended matter and total phospho- loads entering the biological part. Therefore, by
rus. The analyses were performed in the waste- increased effectiveness of elimination of the solid
water treatment plant laboratory using recom- phase from wastewater stream in the pre-settling
mended laboratory methods: COD Merck method tanks, the load of biological chambers with pol-
1.14541.0001, BOD5 – PN-EN 1899, total sus- lutants is reduced, resulting in practical benefits.
pended matter – PN-EN 872, total phosphorus – Those benefits originate, first and foremost, from
Merck method 1.14729.0001. the reduction of excess sludge increase, with a si-
Furthermore, variations of the height of the multaneous reduction of the oxygen consumption
clarified zone in secondary settling tanks No 1 and demand. By applying such solution we strive
and No 2, monitored in March 2016, are present- for improvement of the economic and energetic
ed in this paper. Variations of the clarified zone wastewater treatment effectiveness.
are illustrated in a graph based on the on-line The coagulation process conducted before the
record of Turbimax CUS71D Endress+Hauser pre-settling tanks definitely improved the quality
probe, under normal wastewater flow conditions of mechanically purified wastewater. Neverthe-
(during a single day) and during water hammer- less, the lack of chemical support of sedimen-
ing (two days). At the same time, SUPERFLOC tation process in the pre-settling tanks contrib-
polymer was added during the experiment into uted, in connection with the periodical prob-
settling tank No 2 to improve the deposit sedi- lem of preliminary sludge disposal (due to low
mentation rate. Secondary settling tank No 1 op- temperature), to deterioration of the solid phase
erated without flocculant additive, which allowed separation results. The height of sludge laying in
for comparison and testing of its effectiveness in pre-settling tanks at that period (without chemi-
phase separation. cal support from PRAESTOL 2530 flocculant),
measured with hand-operated Burkle Vampire
Sampler, was approximately 1 metre below the
RESEARCH RESULTS wastewater table. Reintroduction of the chemi-
cal support from PRAESTOL 2530 caused re-
Supporting of wastewater treatment with co- duction of sludge layer height in the pre-settling
agulant and polymer in the mechanical stage is tanks down to approximately 3.4 metre below the
particularly significant due to high variability of wastewater table.
raw wastewater composition, practically during The absence of chemical sedimentation sup-
the entire year. Variability of concentration of the port in the analysed period caused a significant
analysed indicators in raw wastewater and after deterioration of the mechanical wastewater treat-
sedimentation in the pre-settling tank is illustrat- ment results. Table 1 shows examples of the anal-
ed in Figures 2–5. The presence of pre-settling ysed parameters values achieved after the pre-set-
tanks supported by chemical precipitation al- tling tank without flocculant application, which
lows for reduction and stabilisation of pollutant are similar to those of raw wastewater.
Figure 2. COD values in raw wastewater (ChZT s) and after pre-settling tank No 1 (ChZT 1) in 2015
83
Journal of Ecological Engineering Vol. 19(6), 2018
Figure 3. BOD5 values in raw wastewater (BZT5 s) and after pre-settling tank No 1 (BZT5 1) in 2015
Figure 4. Total suspended matter values in raw wastewater (Zaw. Og. s) and beyond the pre-settling tank No 1
(Zaw. Og. 1) in 2015
Figure 5. Total phosphorus values in raw wastewater (P og. s) and beyond the pre-settling tank No 1 (P og. 1)
in 2015
84
Journal of Ecological Engineering Vol. 19(6), 2018
During the research period, the performance tent. The PIX – 113 preparation, which has been
of the secondary settling tanks was also observed. applied for many years, considerably eliminates
Flocculant is added in Koszalin wastewater treat- hydrogen sulphide from wastewater. Further-
ment plant, depending on needs, also into the more, it improves the condition of the activated
secondary settling tanks, in which the activated sludge thus improving the operation of the bio-
sludge is separated from the purified wastewater logical part of the plant. During a long-term op-
through sedimentation. Under normal flow condi- eration of said wastewater treatment plant, it was
tions, such separation proceeds without any distur- noted that cessation or reduction of coagulant
bance, and the sludge sedimentation rate depends addition to raw wastewater led to an excessive
on its concentration. If the sludge concentration increase of the total phosphorus concentration
is high, the rate of its sedimentation considerably in the supernatant water and effluents from the
decreases. In Figure No 6, variations of the height sludge management returned to the main stream
of activated sludge in the secondary settling tanks of raw wastewater. An additional advantage of
under variable flow conditions, during addition of using PIX in preliminary chemical precipitation
Superfloc C 18450 polymer, are illustrated. The performed at the mechanical part of the waste-
difference of height between a well-concentrated water treatment plant, can be the reduction of
sludge layer in the pre-settling tank No 2, sup- biological reactors volume and operating costs,
ported by addition of Superfloc C 18530, and the particularly reduction of electrical power con-
concentrated sludge layer without the reagent sumption cost. This operation had an impact on
was, during water hammering, maximum 50 cm. reduction of the excess sludge volume, whereas
Under normal flow conditions, this difference the increased volume of the preliminary sludge
was 20 cm on average (Maciołek, 2016). The (30÷60% reduction of the total suspended matter)
difference in sludge layer height was determined promoted the process of anaerobic stabilisation of
through direct on-line measurements of height mixed sludge. It appears from laboratory tests and
of the clarified layer using Turbimax CUS71D observation of the wastewater treatment plant op-
Endress+Hauser probes, set for “distance from eration, that pre-settling tanks make an important
water to the dead zone” measurement mode. The and essential part before the biological process of
added flocculant (quarternary polyamine) caused, biogenic compounds elimination. They protect
under normal flow conditions (1 day), a quick the biomass from elution of phosphorus eliminat-
change of the sludge concentration, which was ing bacteria and allow for intensification of the
confirmed by the on-line record. The height of the nitrogen and phosphorus elimination from waste-
clarified zone during polymer addition remained water. Improperly performed preliminary coagu-
similar to that under low flow conditions. During lation process may deteriorate the denitrification
an increased inflow of wastewater, the sludge was and nitrification effectiveness [Malej, 2000a,
intensely mixed and agitated, causing interference Malej, 2008, Szyszko, 2015]. The speed of those
in readings. This may prove limited application of processes is reduced radically.
Turbimax CUS71D probes set for “distance from
water to the dead zone” measurement mode under
normal flow conditions. CONCLUSIONS
The “Jamno” Wastewater Treatment Plant
also collects wastewater from rural areas. Such Total phosphorus is eliminated in „Jamno”
wastewater features high hydrogen sulphide con- Wastewater Treatment Plant approximately at the
Table 1. Listing of parameters of mechanically treated wastewater beyond the pre-settling tank no 1 without floc-
culant added
Tested parameter
Date
COD [mg/l O2] BOD5 [mg/l O2] Tot. s.m. [mg/l] Tot. P [mg/l]
2018–02–06 1900 560 1200 25,8
2018–02–20 2340 1380 1300 29,2
2018–02–27 1306 400 550 22,7
2018–03–06 1142 - 430 16,3
Average value 1672 780 870 23,5
85
Journal of Ecological Engineering Vol. 19(6), 2018
Figure 6. Variations of height of the clarified zone in the secondary sedimentation tanks No 1 (blue) and No 2
(green) with flow rate shown in the background (full graph – grey) and the measurements of turbidity (violet)
under normal wastewater flow conditions – 1th day (left area) and during water hammers – 2nd and 3rd day (middle
and right areas). SUPERFLOC indicates the area in the course of addition of the polymer improving sludge
sedimentation rate
level of 50%, already after the mechanical stage chamber before the secondary settling tanks; this
of wastewater treatment supported by prelimi- allows for considerable improvement of the phos-
nary precipitation with iron (III) sulphate (VI) phorus elimination efficiency.
with the trade name of PIX – 113. Furthermore, In the event of intensified rainfall, causing in-
the coagulant doses of 50 – 100 g/m3 allow for creased hydraulic load in the secondary settling
BOD5 reduction by approximately 50 – 60%, thus tanks, the use of the polymer ultimately led to the
reducing the reactors capacity by half. achievement of positive effects, preventing flota-
High variability of raw wastewater compo- tion of the sludge outside overflow channels of
sition caused, as indicated by the test results of the secondary settling tanks.
2015 presented herein, very high variations in
the biological part load during the year, when the
coagulant and flocculant were not added into the REFERENCES
pre-settling tanks,. Such irregularity may imply a
non-uniform increase of the excess sludge, oxy- 1. Cherchi C., Onnis-Hayden A., El-Shawabkeh
gen consumption and demand, concentration of I.N., Gu A.Z. 2009. Implication of using different
carbon sources for denitrification in wastewater
nitrogen forms and the external and internal recir- treatments. Water Environment Research, 81(8),
culation degree associated therewith. 788–799.
Despite the application of a highly efficient 2. Dziubek, A.M., Kowal, A.L. 1988. High-pH co-
biological dephosphatization method, it is still agulation-adsorption: a new technology for water
necessary to add PIX before the pre-settling treatment and reuse, Water Science and Technol-
tanks. The PIX-113 coagulant can be added in ogy, 21, 1183–1188.
said wastewater treatment plant simultaneously 3. Dincer K., Kargi F. 2000. Effects of operating pa-
into the biological reactors and to the distribution rameters on performances of nitrification and deni-
86
Journal of Ecological Engineering Vol. 19(6), 2018
trification processes. Bioprocess Engineering, 23, rzystaniem zewnętrznego źródła węgla organicz-
75–80. nego. Rocznik Ochrona Środowiska, 18, 885–896.
4. Duan, J., Gregory, J. 2003. Coagulation by hydro- 10. Malej J., Boguski A. 2000. Zmiany ilościowe
lysing metal salts, Advances in Colloid and Inter- ładunku zanieczyszczeń w cieczy nadosadowej w
face Science, 100 –102, 475–502. procesie zagęszczania osadu czynnego. Rocznik
5. Hansen B. 2002. Chemiczne oczyszczanie ścieków Ochrony Środowiska.
– stare i nowe zastosowania. Nowe rozwiązania 11. Malej J. 2008. Wysoko sprawne oczyszczal-
problemów technicznych w oczyszczalniach nie ścieków a zagrożenia kąpielisk publicznych.
ścieków. Materials from a scientific and techni- Wodociągi – Kanalizacja, No. 11.
cal seminar held in Świnoujście and Copenhagen. 12. Malej J. 2000. Właściwości osadów ściekowych
Szczecin. oraz wybrane sposoby ich unieszkodliwiania i uty-
6. Klaczyński E. 2013. Oczyszczalnia ścieków – lizacji. Rocznik Ochrony Środowiska
chemiczne usuwanie fosforu, Wodociągi – Kanali- 13. Piaskowski K., Ćwikałowska M. 2007. Profil zmi-
zacja, No 2. an stężenia ortofosforanów podczas oczyszczania
7. Lemmer H. 2000. Przyczyny powstawania i zwal- ścieków i przeróbki osadów ściekowych. Rocznik
czania osadu spęczniałego. ATV monography se- Ochrony Środowiska.
ries. Wydawnictwo Seidel-Przywecki. Szczecin. 14. Przywara L. 2006. Warunki i możliwości usu-
8. Maciołek P. 2016. Wpływ polimeru kationowego wania fosforanów i fosforu ogólnego ze ścieków
Superfloc C 18530 na właściwości sedymentacyjne przemysłowych. rozprawa doktorska, Politechnika
osadu czynnego w zróżnicowanych warunkach Krakowska.
przepływu. Technologia Wody, 3(47). 15. Szyszko M. 2015. Wpływ strącania wstępnego po-
9. Maciołek P., Szymański K., Janowska B. 2016. limerem organicznym na szybkość denitryfikacji,
Usuwanie azotu ze ścieków komunalnych z wyko- www.eko-dok.pl
87