Sunteți pe pagina 1din 28

PART H - BILLS OF QUANTITIES

SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 1 - WORK BELOW LOWEST FLOOR


FINISH

Excavate, get out, part return, fill in and ram and


deposit and spread in making up levels where
directed within the site and remainder load and cart
away

A Oversite to reduce level m3 23

B Pad footing not exceeding 1.50m deep (Provisional) m3 63

C Trench for ground beam not exceeding


1.50m deep m3 10

________________________________________

D 150mm Thick bed of hardcore as described, spread,


levelled, well rammed and consolidated, watered and
blinded with fine sand, well rolled in and finished
under apron slab (measured separately) m2 33

Concrete Grade 15 as described

E 50mm Thick blinding screed, spread and levelled


under pad footing m2 53

F 50mm Thick ground beam m2 20

G 50mm Thick ground floor slab m2 155

H 50mm Thick apron slab m2 33

Reinforced concrete Grade 30 as described

J Pad footing m3 14

K Column stump m3 1

To Collection :

MPOB H(b)/1/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 1 - WORK BELOW LOWEST FLOOR


FINISH (Cont'd)

Reinforced concrete Grade 30 as described

A Ground beam m3 6

B 125mm Thick ground floor slab m2 155

C 125mm Thick apron slab m2 33

Mild steel reinforcement bar as described

D 6mm Diameter as links in column stump kg. 42

E 6mm Ditto as starter bar in apron slab kg. 35

High tensile steel reinforcement bar as


described

Pad footing

F 12mm Diameter kg. 800

G 6mm Ditto as ties kg. 60

Column Stump

H 10mm Diameter kg. 125

Floor Slab

J 10mm Diameter kg. 2,053

To Collection :

MPOB H(b)/1/2
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 1 - WORK BELOW LOWEST FLOOR


FINISH (Cont'd)

High tensile steel reinforcement bar as


described (Cont'd)

Ground Beam

A 25mm Diameter kg. 21

B 20mm Ditto kg. 100

C 16mm Ditto kg. 123

D 12mm Ditto kg. 415

E 10mm Ditto as stirrups kg. 514

Layer of steel reinforcement to MS : 145 1987 as


described (Ref. No. A7) weighing not less than 3.02
kg/m2 well lapped at joints and embebbed in
concrete (measured nett-no allowance made for
laps)

F Apron slab m2 33

Sawn formwork as described

G Sides of pad footing m2 43

H Ditto column stump m2 18

J Ditto ground beam m2 98

K Edge of concrete not exceeding 100mm high m 20

To Collection :

MPOB H(b)/1/3
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 1 - WORK BELOW LOWEST FLOOR


FINISH (Cont'd)

A Prepare and apply a layer of 0.25mm thick polythene


sheet well lapped at joints as specified (measured
nett - no allowance made for laps under ground floor
slab) m2 155

B Approved termiticide chemical treatment applied


strictly in accordance to the manufacturer's
recommendation and instruction prior to the pouring
of concrete for foundations, ground floor slab, ground
beam and apron slab including Guarantee against any
termite attack to the Works for a period of two (2)
years from the date of Practical Completion of the
works to the approval of the S.O m2 420

To Collection :

Collection

From Page No. H(b)/1/1 ...............................

From Page No. H(b)/1/2 ...............................

From Page No. H(b)/1/3 ...............................

From Page No. H(b)/1/4 ...............................

TOTAL ELEMENT NO. 1 - WORK BELOW LOWEST


FLOOR FINISH - CARRIED TO SUMMARY :

MPOB H(b)/1/4
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 2 - FRAME

Reinforced concrete Grade 30 as described

A Column m3 2

B Roof beam m3 5

Mild steel reinforcement bar as described

Column

C 6mm Diameter as links kg. 113

Roof Beam

D 6mm Diameter as stirrup kg. 170

High tensile steel reinforcement bar as described

Column

E 10mm Diameter kg. 230

Roof Beam

F 16mm Diameter kg. 7

G 12mm Ditto kg. 503

Sawn formwork as described

H Sides of column m2 45

J Sides and soffit of roof beam m2 76

TOTAL ELEMENT NO. 2 - FRAME - CARRIED TO


SUMMARY :

MPOB H(b)/2/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 3 - ROOF

TENDERER PROPOSED PROPRIETORY LIGHT


WEIGHT STEEL ROOF TRUSS SYSTEM

A i) The tenderer shall design, fabricate and deliver to


side and furnish at his expense all necessary
materials, tools, hoists, staging, temporary bracing,
etc for the safe and proper erection of the
fabricated light weight steel trusses complete with
rafter, top and bottom chords, ties, struts, bearers,
wall plates, packing pieces, steel truss connectors,
straps, mild steel holding bolts, battens and other
associated and obvious item required for the works
all to the satisfaction of the S.O.

B ii) The design of light weight steel roof trusses shall


be by an approved manufacturer of fabricated roof
trusses. The light weight steel roof trusses shall be
designed all in accordance with the specification
and Architect's/Engineer's drawing. The
Contractor shall note that the light weight steel roof
trusses shall be design to suit the roof covering,
ceiling, aircond duct, piping, wiring trays, etc. in the
case where the roof trusses is designed at centres
which does not suit or facilitate the fixing of the
ceiling, the Contractor shall include in his design of
the roof trusses for any additional bearers, tie
beams, ceiling joist, etc required to facilities the
ceiling panels. The Contractor shall deemed to have
thoroughly acquainted himself with this
requirements and allow for such additional cost
due to extra members required as no claim on this
will be entertained

C The Contractor shall note that he shall be solely


responsible for the adequacy and sufficiency of the
roof trusses and members provided for the ceiling
panels

To Collection :

MPOB H(b)/3/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 3 - ROOF (Cont'd)

TENDERER PROPOSED PROPRIETORY LIGHT

WEIGHT STEEL ROOF TRUSS SYSTEM (Cont'd)

Guarantee

A The Contractor shall provide a written guarantee


from the Manufacturer for a period of twenty five
(25) years and as approved by the S.O. from the
date of practical completion to cover against faulty
materials workmanship, installation and other
defect or design fault, hereby all failure or
fabricated light weight steel roof trusses system in
the whole or in part to be rectified at no cost Item - -

Rates to include

B Rates for light weight steel roof trusses and rafters


shall include for all necessary materials, approved
five (5) years of anti corrosion coating,
fabrications, delivery to site, hoisting and fixing in
position, all fixing accessories including mild steel
holding downs bolts or ram setting, all ancillary
works and temporary works for the complete
installation of the trusses. Rate for the light weight
steel trusses shall also included for design fees and
all necessary cost for patent right design,
trademark or named Item - -

C The design of the whole roof truss system shall be


properly examined and certified by a
PROFESSIONAL STRUCTURAL ENGINEER. The
Contractor is required to produce and submit to the
S.O. the certified proposed drawings together with
his Tender Document and if accepted thereafter to
submit not less than two (2) sets certified working
and as-built drawings during and after construction Item - -

To Collection :

MPOB H(b)/3/2
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 3 - ROOF (Cont'd)

TENDERER PROPOSED PROPRIETORY LIGHT

WEIGHT STEEL ROOF TRUSS SYSTEM (Cont'd)

A Design, supply, fabricate and deliver to site


including fixing and hoisting in position approved
type patented propriatory light weight steel roof
trusses roof structural system from approved roof
Manufacturer and installer including all steel roof
truss, rafter, chord, bearers, tie, strut, packing
piece, truss connector, straps, tie rod, purlin,
painting and other associated works, material and
labour required for the complete installation of the
fabricated light weight steel roof trusses to the
approval of the Engineer's approximately 6m
height from ground level (approximately 215m2) L.S -

Roof Covering

B 0.47mm Thick TCT - metal deck clean colorbond


steel roofing sheet with colour to be selected by S.O.
and to be fixed by approved specialist to purlin
(measured separately) in accordance with
manufacturer's instruction (measured nett-no
allowance made for laps) m2 215

C Single layer of 50mm thick compressed


rockwool insulation (32kg/m3 density) as
described laid over chicken wire mesh (measured
separately) m2 215

D Layer of single sided alumimium 2.5mm thick foil


building paper fixed to steel trusses all done in
accordance with manufacturer's instruction
(measured nett-no allowance made for laps) m2 215

To Collection :

MPOB H(b)/3/3
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 3 - ROOF (Cont'd)

Roof Covering (Cont'd)

A One layer of an approved chicken wire mesh secure


fastened to mild steel members (measured
separately) m2 215

B 250mm x 12mm Thick cement fascia board


including all necessary work. m 60

C 32 Gauge galvanised iron flashing as described


1070mm girth four times bent with one end fixed to
brickwall and another end dressed over roof
covering m 11

D 32 Gauge galvanised iron flashing as described


400mm girth two times bent and dressed over roof
covering m 16

________________________________________

E Prepare and apply one coat metallic primer, one


undercoat and two finishing coats of approved
gloss enamel paint as described to match roof
colour to general surface of flashing m2 18

F Prepare and apply one coat alkali resisting primer


sealer and two coats of emulsion paint as described
to general surfaces of fascia board m2 31

To Collection :

MPOB H(b)/3/4
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 3 - ROOF (Cont'd)

Collection :

From Page No. H(b)/3/1 ………………………

From Page No. H(b)/3/2 ………………………

From Page No. H(b)/3/3 ………………………

From Page No. H(b)/3/4 ………………………

TOTAL ELEMENT NO. 3 - ROOF - CARRIED TO


SUMMARY :

MPOB H(b)/3/5
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 4 - EXTERNAL WALL

A Half brickwall in cement and sand brick in


composition mortar (1:3) as described reinforced
with and including brick reinforcement m2 142

B One - brickwall in clay brick ditto as fire rated party


wall m2 4

C Horizontal damp proof course as described laid on


half brick wall lapped at joints and junctions
(measured nett-no allowance made for laps) m 44

D Ditto one brickwall ditto m 9

E 6mm Diameter mild steel as described bonding tie


450mm girth, one end hooked and cast into concrete
and other end built into joints of brickworks including
perforation in formwork No. 273

TOTAL ELEMENT NO. 4 - EXTERNAL WALL -


CARRIED TO SUMMARY :

MPOB H(b)/4/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 5 - INTERNAL WALL

A Half brickwall in cement and sand brick in


composition mortar (1:3) as described reinforced
with and including brick reinforcement m2 146

B One - brickwall in clay brick ditto as fire rated party


wall m2 55

C Horizontal damp proof course as described laid on


half brick wall lapped at joints and junctions
(measured nett-no allowance made for laps) m 39

D Ditto one brickwall ditto m 9

E 6mm Diameter mild steel as described bonding tie


450mm girth, one end hooked and cast into concrete
and other end built into joints of brickworks including
perforation in formwork No. 63

TOTAL ELEMENT NO. 5 - INTERNAL WALL -


CARRIED TO SUMMARY :

MPOB H(b)/5/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 6 - WINDOWS

A Reinforced concrete Grade 30 as described lintols m3 1

B 6mm Diameter mild steel reinforcement bar as


described as stirrup in lintol kg. 68

C 10mm Ditto high tensile steel reinforcement bar as


described in lintol kg. 135

D Sawn formwork as described to sides and soffit of


lintol m2 26

Supply, deliver to site and fix approved Natural


Anodised aluminium window frame as described
infilled with glass (measured separately) including all
necessary frames, transome, mullions, glazing
materials, glazing beads, fixing screws, ironmongeries
and accessories

E Composite adjustable and fixed glass louvres window


overall size 1800mm x 1700mm high comprising of 3
nos. equal adjustable louvres panels each size 600mm
x 1200mm high and 3 nos. equal fixed louvres panels
each size 600mm x 500mm high at the top (Type W1) No. 12

F Ditto overall size 1200mm x 1700mm high


comprising of 2 nos. equal adjustable louvres panels
each size 600mm x 1200mm high and 2 nos. equal
fixed louvres panels each size 600mm x 500mm high
at the top (Type W2) No. 2

G Ditto fixed glass louvres top hung window overall size


1800mm x 500mm high comprising of 3 nos. equal
fixed louvres panels each size 600mm x 500mm high.
(Type HW2) No. 2

To Collection :

MPOB H(b)/6/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 6 - WINDOWS (Cont'd)

A 10mm Diameter mild steel solid security bar fix


through window frame (measured separately) m 168

B 6mm Thick clear glass louvres blades 150mm wide


with ground and polished edges and fixing both ends
into clips of louvres stiles m 192

C Prepare and apply one coat alkyd based rust


preventing primer and two finishing coats of
approved gloss enamel paint to general surfaces of
metal work not exceeding 100mm girth as described
security bar m 168

To Collection :

Collection :

From Page No. H(b)/6/1 …………………………

From Page No. H(b)/6/2 …………………………

TOTAL ELEMENT NO. 6 - WINDOWS - CARRIED TO


SUMMARY :

MPOB H(b)/6/2
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 7 - DOORS

A Reinforced concrete Grade 30 as described lintols m3 1

B 6mm Diameter mild steel reinforcement bar as


described as stirrup in lintol kg. 23

C 10mm Ditto high tensile steel reinforcement bar as


described in lintol kg. 53

D Sawn formwork as described to sides and soffit of


lintol m2 9

E 50mm x 150mm x 150mm High precast concrete


Grade 20 as described heelstone including all moulds,
finishing fair on exposed surface, bedded in cement
mortar (1:3) and cast to profile of door frame with
and including all necessary formwork and 10mm
diameter mild steel dowel bar 100mm long No. 8

Supply, deliver to site and install approved 162mm


wide hot dipped zincalume door frame in standard
frame profile and including cornices and special wire
brick and/or brackets striker plate, spreader bar,
mounting bracket cushioning rubber buffers, rust
proof cadmium-plated on stainless steel hinges, and
fixing screws and ironmongeries including all
necessary cement and sand (1:3) mortar infill all in
accordance to manufacturer's instruction

F 1.2mm Thick frame size 900mm x 2600mm high for


single leaf composite flush door (Type D1) No. 4

G 1.2mm Thick ditto 900mm x 2100mm high for single


leaf timber panel door (Type D2) No. 6

H 1.2mm Thick ditto 750mm x 2100mm high for single


leaf PVC door (Type D3) No. 4

To Collection :

MPOB H(b)/7/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 7 - DOORS (Cont'd)

Skeleton frame plywood flush door in Wrot Group 'A'


timber as described constructed of 25mm x 100mm
thick top, intermediate and bottom rail, covered both
sides with 6mm thick plywood with and including
38mm x 10mm thick edging piece all round and
mitred at angle

A 38mm Thick composite door overall size 900mm x


2100mm high (Type D1) No. 4

B 38mm Thick panel door overall size 900mm x


2100mm high (Type D2) No. 6

C 38mm Thick PVC door overall size 750mm x


2100mm high (Type D3) No. 4

Supply and fix the following ironmongeries including


all necessary matching screws

D SS Knob trim with heavy duty forget 8" x 2"


escutcheon mortice deadbolt by key outside and
thumturn inside with 3/4" lachbolt c/w acces No. 10

E Indicator knob lockset No. 4

_________________________________________

F Knotting, stopping and apply one coat primer one


undercoat and two finishing coats gloss enamel paint
as described on general surfaces of flush door m2 42

G 10mm Diameter mild steel solid security bar fix


through window frame (measured separately) m 15

To Collection :

MPOB H(b)/7/2
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 7 - DOORS (Cont'd)

A 6mm Thick frosted glass louvres blades 150mm wide


with ground and polished edges and fixing both ends
into clips of louvres stiles m 15

To Collection :

Collection :

From Page No. H(b)/7/1 …………………

From Page No. H(b)/7/2 …………………

From Page No. H(b)/7/3 …………………

TOTAL ELEMENT NO. 7 - DOORS - CARRIED TO


SUMMARY :

MPOB H(b)/7/3
PART H - BILLS OF QUANTITIES SECTION 1 - SECTIONAL COMPLETION 1
SECTION 2 - BUILDING WORKS BILL NO. 1 - HOUSES (2 UNITS)

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 8 - INTERNAL WALL FINISHES

A 20mm Thick cement and sand (1:6) mixed with an


approved plasticiser as described plainface to wall
and column m2 430

B 13mm Thick cement and sand (1:3) as


described backing screed to receive wall tiles
(measured separately) to walls and columns m2 30

C 200mm x 200mm x 7mm Thick ceramic wall tiles laid


in colour and patterns by the S.O. bedded and jointed
in cement mortar (1:3) and pointed in coloured
cement on backing screed (measured separately) to
walls and columns m2 30

D Prepare and apply one coat of alkali resisting primer


sealer and two coats emulsion paint as described to
plastered wall and column m2 430

TOTAL ELEMENT NO. 8 - INTERNAL WALL


FINISHES - CARRIED TO SUMMARY :

MPOB H(b)/8/16
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 9 - INTERNAL FLOOR FINISHES

Cement and sand (1:3) as described

A 13mm Thick paving trowelled smooth to floor m2 135

B 13mm Thick screed to floor to received ceramic floor m2 9


tiles

C 13mm Thick ditto to drop or riser 50mm high m 3

200mm x 200mm x 8.5mm Thick Ceramic floor tiles


laid in colour and pattern and approved by the S.O.,
bedded and jointed in cement and sand (1:3) mortar
as described and pointed with cement mortar (1:3) as
described

D Laid to floor m2 9

E Laid to drop or riser 50mm high m 3

TOTAL ELEMENT NO. 9 - INTERNAL FLOOR


FINISHES - CARRIED TO SUMMARY :

MPOB H(b)/9/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 10 - INTERNAL CEILING FINISHES

A 100mm x 50mm Sawn pressure treated Group 'B'


timber as described ceiling joist m 306

B 50mm x 50mm Ditto nogging m 146

C 75mm x 13mm Wrot pressure treated Group 'C'


timber decorative cornice m 180

D 3.2mm Thick asbestos free ceiling sheet lining set out


symmetrically from centre of room in panel of
1200mm x 600mm fixed to timber frame (measured
separately) m2 148

E Extra over for forming accesss panel overall size


600mm x 600mm including all additional
timber framing No. 2

F Prepare and apply one coat alkali resisting primer


sealer and two coats of emulsion paint as described to
general surfaces of ceiling board m2 148

G Knotting, stopping and apply coat primer, one


undercoat and two finishing coats gloss enamel paint
as described on general surfaces of woodwork not
exceeding 100mm girth m 180

TOTAL ELEMENT NO. 10 - INTERNAL CEILING


FINISHES - CARRIED TO SUMMARY :

MPOB H(b)/10/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 11 - EXTERNAL FINISHES

Floor

Cement and sand (1:3) as described paving


trowelled smooth

A 20mm Thick to apron m2 62

B 20mm Thick to drop or riser 100mm high m 2

Wall

Cement and sand (1:6) as described mixed with an


approved plasticiser externally as described
plainface to the following surfaces

C 20mm Thick to wall and column m2 179

Prepare and apply one coat alkali resisting


primer sealer and two coats of 'weathershield'
paint as described on plastered surfaces

D Wall and column m2 179

Ceiling

E 50mm x 100mm Sawn pressure treated Group 'B'


timber as described ceiling joist m 43

F 50mm x 50mm Ditto nogging m 21

G 75mm x 13mm Wrot pressure treated Group 'C'


timber decorative cornice m 69

To Collection :

ECER-BS Agropolitan BQ/1/1


PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 11 - EXTERNAL FINISHES

Ceiling (Cont'd)

A 3.2mm Thick asbestos free ceiling sheet lining set


out symmetrically from centre of room in panel of
1200mm x 600mm fixed to timber frame
(measured separately) m2 66

B Prepare and apply one coat alkali resisting primer


sealer and two coats of emulsion paint as described
to general surfaces of ceiling board m2 66

To Collection :

Collection :

From Page No. H(b)/11/1 …………………

From Page No. H(b)/11/2 …………………

TOTAL ELEMENT NO. 11 - EXTERNAL FINISHES -


CARRIED TO SUMMARY :

ECER-BS Agropolitan BQ/1/2


PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 12 - BUILDER'S WORK IN


CONNECTION WITH SERVICES

Reinforced concrete Grade 30 as described

A 200mm Thick water closet stooling m2 7

B 75mm Thick concrete counter top m2 3

C Layer of steel reinforcement to MS : 145 1987 as


described (Ref. No. A8) weighing not less than 3.95
kg/m2 well lapped at joints and embebbed in
concrete (measured nett-no allowance made for
laps) m2 3

D Extra over for temporary boxing no 2

Sawn formwork as described

E Sides and soffit of concrete counter top m2 3

F Edge of water closet stooling exceeding 200mm high


and not exceeding 300mm high m 3

Cement and sand (1:3) screed as described

G 20mm Thick to receive ceramic floor tiles (measured


separately) to water closet stooling m2 4

H 20mm Thick to water closet stooling 200mm high m 4

J 20mm Thick to receive ceramic floor tiles (measured


separately) to counter top m2 3

To Collection :

ECER-BS Agropolitan BQ/1/21


PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY. RATE AMOUNT


(RM) (RM)

ELEMENT NO. 12 - BUILDER'S WORK IN


CONNECTION WITH SERVICES (Cont'd)

200mm x 200mm x 7mm Thick ceramic tiles laid in


colour and pattern and approved by the S.O., bedded
and jointed in cement and sand (1:3) mortar as
described and pointed with cement mortar (1:3) as
described

A Water closet stooling m2 4

B Extra over for cove tile m 4

C Concrete counter top m2 3

D Edge of water closet stooling 200mm high m 4

To Collection :

Collection :

From Page No. H(b)/12/1 …………………

From Page No. H(b)/12/1 …………………

TOTAL ELEMENT NO. 12 - BUILDER'S WORK IN


CONNECTION WITH SERVICES - CARRIED TO
SUMMARY :

ECER-BS Agropolitan BQ/1/22


PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 -RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 13 - SANITARY FITTINGS

Supply and fix the following in approved sanitary


fittings and appliances, including storing and
assembling, bedding, plugging and screwing with
matching screws, cutting and pining or building
brackets, jointing and connection to cold water
services and soil pipes and making good all works
disturbed all to manufacturer's recomendations and
S.O approval :-

Squatting Water Closet

A Squatting pan water closet with 'P' trap, complete


with high level cistern and cover, fittings and integral
foot rest No. 2

C Shower rose and arm complete with chrome plated


stop cock No. 2

Kitchen Sink

D Approved single bowl single drainer stainless steel


sink complete with 13mm diameter swivel spout
pillar tap, 40mm 'P' or 'S' trap with 40mm stainless
steel waste outlet fitting with rubber plug and bead
chain stay, plugged and screwed to tiled brickwall
with approved painted cast iron supports as specified No. 2

Bib Tap

A Bib tap No. 4

Floor Trap

B PVC floor trap cover overall size 150mm x 150mm No. 4

To Collection :

MPOB H(b)/13/1
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 -RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 13 - SANITARY FITTINGS (Cont'd)

Supply and fix the following in approved sanitary


fittings and appliances, including storing and
assembling, bedding, plugging and screwing with
matching screws, cutting and pining or building
brackets, jointing and connection to cold water
services and soil pipes and making good all works
disturbed all to manufacturer's recomendations and
E.R's approval :- (Cont'd)

Bib Tap

A Bib tap No. 2

Floor Trap

B PVC floor trap cover overall size 150mm x 150mm No. 3

To Collection :

Collection :

From Page No. H(b)/13/1 …..……………….

From Page No. H(b)/13/2 …..……………….

TOTAL ELEMENT NO. 13 - SANITARY FITTINGS -


CARRIED TO SUMMARY :

MPOB H(b)/13/2
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

ITEM DESCRIPTION UNIT QTY RATE AMOUNT


(RM) (RM)

ELEMENT NO. 14 - EXTERNAL WORK WITHIN


BUILDING LOT (ALL PROVISIONAL)

Perimeter Drain

A Excavate trench for perimeter drain not exceeding


1.50m deep and average 600mm deep get out, part
return, fill in and ram and deposit and spread in
making up levels where directed within the site and
remainder load and cart away m 64

B 50mm Thick lean concrete Grade 15 as described


blinding screed, spread and levelled under drain bed
laid to fall m2 4

C Concrete Grade 20 as described drain bed laid to fall m3 4

D Sawn formwork as described to edge of drain


exceeding 100mm not exceeding 200mm high m 128

E 230mm Diameter half round approved glazed precast


concrete Grade 20 perimeter drain 40mm thick and
cast in 600mm lengths and jointed in cement and
sand (1:3) as described mortar laid to falls on
concrete bed (measured seperately) including
concrete surround, ends, angle and junctions m 64

F Half brickwall in common bricks in completion


cement and sand (1:4) as described to sides of drain m2 18

G 20mm Thick cement and sand (1:4) as described


rendering to top and sides of drain wall m2 29

Precast concrete Grade 20 as described

H 600mm x 450mm x 50mm Thick concrete cover No. 15

TOTAL ELEMENT NO. 14 - EXTERNAL WORK


WITHIN BUILDING LOT (ALL PROVISIONAL) -
CARRIED TO SUMMARY :

MPOB H(b)/14/26
PART H - BILLS OF QUANTITIES
SECTION 2 - BUILDING WORKS BILL NO. 1 - RUMAH PEKERJA

SUMMARY

Element
Description Amount (RM)
No.

1 WORK BELOW LOWEST FLOOR FINISH

2 FRAME

3 ROOF

4 EXTERNAL WALL

5 INTERNAL WALL AND PARTITION

6 WINDOWS

7 DOORS

8 INTERNAL WALL FINISHES

9 INTERNAL FLOOR FINISHES

10 INTERNAL CEILING FINISHES

11 EXTERNAL FINISHES

12 BUILDER'S WORK IN CONNECTION WITH SERVICES

13 SANITARY FITTINGS

14 EXTERNAL WORK WITHIN BUILDING LOT (ALL PROVISIONAL)

X 2

TOTAL - CARRIED TO SUMMARY OF TENDER :

MPOB H(b)/15/1

S-ar putea să vă placă și