VSP

MICROCODE VERSION 70-02-80-00/00-MO92


RELEASED 03/21/2012

New supported features and functions for Version 70-02-80-00/00-MO92


1. Mainframe & OPEN System
NONE

2. Mainframe System
NONE

3. OPEN System

3-1 Support for HMO67


Description New Host Mode Option 067 is available to change the E_D_TOV value used for error
detection in direct Fibre Channel connection. Restricted Mode – Technical Support
Permission Required to Use
Changed Part DKCMAIN, Config
Note Set HMO067 to OFF on all ports within the storage system before downgrading the micro-
program to an unsupported version. (Online/offline)

The change of contents for Version 70-02-80-00/00-MO92


1 Data inconsistency in data migration from EMC storage
Phenomena After data migration is performed from EMC to RAID700 using FICON
Data Migration, a host job may end abnormally on the target volume due
to data inconsistency. The following phenomena may occur.
- When DB2 is executed, the error message DSNB224I or DSNB226I is
generated. (No Rec Found or Invalid track Format)
- When a host I/O is received, EQC (Format’x8’, Message’x9’, Byte18-
19:x6388) occurs, and the host job ends abnormally.
(Note) Even if the above phenomena do not occur, the volume for which
data migration is performed using FICON Data Migration may already
have a data inconsistency.
Severity (High, Medium, Low) High
Conditions of Occurrence The failure may occur when all the following conditions are met.
A. RAID700 Ver.70-01-62-00/00 and later
B. Data is migrated using FICON Data Migration
C. The source external storage is EMC
D. A link failure occurs while mapping a registered path during data
migration Note: The link failure in D. is not a link down, but is a bit error
caused by a signal problem.
Affected Products/Version DKCMAIN: 70-01-62-00/00 and higher
HTP: 70-01-63 and higher
Fixed Product/Version DKCMAIN: 70-02-80-00/00 HTP: 70-02-75
Category Mainframe
Changed Part DKCMAIN, HTP

HDS Confidential 1 of 8
2 Data inconsistency Copy-on-Write Snapshot P-VOL or S-VOL
Phenomena One of the following phenomena may occur.
a) When the pairsplit operation is performed for a Copy-on-Write
Snapshot (hereinafter referred to as “CoW”) pair and data is read from S-
VOL, the updated P-VOL data after the pairsplit operation is read instead
of the P-VOL data before the pairsplit operation. As a result, a file system
problem occurs, or applications detect errors.
b) When the pairresync –restore operation is performed for a CoW pair,
and P-VOL data is read while the CoW pair is in the COPY(RS-R) status
or in the PAIR status, the P-VOL data before the pairresync –restore
operation is read instead of the S-VOL data before the pairresync –restore
operation. As a result, a file system problem occurs, or applications detect
errors.
Severity (High, Medium, Low) High
Conditions of Occurrence Phenomenon a) may occur when all the following conditions A, B, and C
are met.
A. RAID700: All the current versions
B. System Option 737 is set to OFF
C. The following shows the conditions for each CoW pair configuration.
C1. Multiple CoW pairs are defined for one P-VOL
C2. One or more CoW pairs described above are in the PSUS status
C3. During P-VOL data update (*1), the pairsplit operation is
performed for the above-described CoW pair in the PAIR status
*1) Data update that occurs in following four environments C3-1 to C3-4
C3-1. Configuration that contains only CoW pairs Write I/O is issued to
P-VOL from the host
C3-2. Configuration where a CoW pair is combined with a TrueCopy pair
P-VOL is TrueCopy S-VOL. While the TrueCopy pair is in the COPY or
PAIR status, initial copy or update copy of TrueCopy pair is performed
C3-3. Configuration where a CoW pair is combined with a Universal
Replicator pair P-VOL is Universal Replicator S-VOL. While the
Universal Replicator pair is in the COPY or PAIR status, initial copy or
update copy of the Universal Replicator pair is performed
C3-4. Configuration where a CoW pair is combined with a ShadowImage
pair P-VOL is ShadowImage S-VOL. While the ShadowImage pair is in
the COPY(RS), PAIR, PSUS(SP), or COPY(SP) status, a copy operation
is performed for the ShadowImage pair.
C4. The CoW pair for which the pairsplit operation is performed does not
have the CTG configuration

Phenomena b) may occur with the following conditions A, B, H, I met.


A. RAID700: All the current versions
B. System Option 737 is set to OFF
H. While a read or write I/O is issued to CoW P-VOL, the pairresync –
restore operation is performed.
I. The above-described pairresync –restore operation is the second or later
pairresync –restore operation for the same P-VOL after the pair is created
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Copy-on-Write Snapshot, TrueCopy, Universal Replicator, ShadowImage
Changed Part DKCMAIN

HDS Confidential 2 of 8
3 HDD may become blocked when SATA-E mode is used
Phenomena When the SATA-E mode is used for SATA HDD, CHK2 may occur due
to a write sequence error. Depending on the number of times the error
occurs a day, the following phenomena occur, and LDEV and/or MP are
blocked and data loss occurs in the worst case.
- It occurs four times in the same drive port -> SIM RC=df6xyy or df7xyy
- It occurs eight times in the same drive port -> The drive port is blocked.
SIM RC=df8xyy or df9xyy is reported.
- Both ports of the same HDD are blocked -> HDD is blocked.
SIM RC=ef0xyy is reported.
- HDD is blocked by exceeding redundancy in same ECC -> LDEVs in
the same ECC group are blocked. SIM RC=dfaxyy or dfbxyy is reported.
- It occurs 128 times in the same logical DMA -> Logical DMA is
blocked.SIM RC=cf6xyy is reported.
- Multiple logical DMAs in the same DMA are blocked -> DMA is
blocked. SIM RC=cf83xx is reported.
- All logical DMAs in the same DKA PCB are blocked -> MP is blocked.
SIM RC=3073xx is reported.
In addition, if this error occurs when there is no redundancy in the same
ECC or when correction read is performed for recovery of a write
sequence error , PIN slot(s) occur(s) and SIM RC=ff4xyy is reported.
Severity (High, Medium, Low) High
Conditions of Occurrence The WSEQ# information may become invalid when all the following
conditions A to C are met.
A. RAID700 micro-program version 70-01-01-00/00 and later
B. The SATA-E mode is used
C. SSB EC=13dc (Write Pending 65% or more) is reported
(Note): In reality, the phenomenon may occur when “Write Pending of
the CLPR to which the HDD that uses the SATA-E mode belongs is 68%
or more”. But in the case of monitoring data, a brief increase in Write
Pending may not be indicated in the data, so check if SSB is output to
determine whether the condition is met. When the WSEQ# information
becomes invalid, if the SATA HDD data is read using the WSEQ#
information, a write sequence error occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Open or Mainframe
Changed Part DKCMAIN

4 Volume deletion failure with SN message 3205-6535 output


Phenomena When a VOL without LUN path definition was deleted, Storage
Navigator message 3205-6535 was output and the operation was disabled.
Severity (High, Medium, Low) High
Conditions of Occurrence The problem occurs when an MP reset occurs during LUN path deletion.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Open or Mainframe
Changed Part DKCMAIN

HDS Confidential 3 of 8
5 SCP remaining with SSB output and possible I/O stall
Phenomena When an MP failure (CHK1B, CHK3, or WCHK1) occurred during
SETCACHE command processing from IBM utility (IDCAMS) or
TDMF (Transparent Data Migration Facility) tool processing, SCP
remained. SSB=7321, 7330, 7328, 7343, 7353, 7373, 7383, 73B0, 73C0,
7393, 73A3, 7230, 7428 or 749F was output and I/O stall might occur.
Severity (High, Medium, Low) High
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Mainframe host connection
(2) SETCACHE command executed from IDCAMS or the TDMF tool.
(3) An MP failure occurs. (CHK1B, CHK3, WCHK1)
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Mainframe
Changed Part DKCMAIN

6 Incorrect response time display


Phenomena When response delay such as I/O time-out frequently occurred, port
response time of Performance Monitor was displayed smaller than the
actual I/O response time.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Performance Monitor is installed.
(2) Host I/O response is delayed.
(3) Port or WWN information is displayed on Performance Monitor.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Open
Changed Part DKCMAIN

7 Failure of monitoring display after SVP code exchange


Phenomena With the following performed, Storage Navigator error message 5105-
66017 was output and monitoring data could not be displayed.
(1) Monitoring data was collected with the monitoring switch ON.
(2) SVP micro-program was downgraded to a version earlier than 70-02-
53/00 and then the sample interval was changed.
(3) SVP micro-program was upgraded to version 70-02-53/00 or higher.
(4) Monitoring data was collected.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when monitoring data is collected in the following
order.
(1) SVP micro-program version 70-02-53/00 and higher is used.
(2) Monitoring data is collected with the monitoring switch ON.
(3) SVP micro-program downgraded to version earlier than 70-02-53/00.
(4) Sample interval is changed.
(5) SVP micro-program is upgraded to version 70-02-53/00 or higher
(6) Monitoring data is collected.
Affected Products/Version SVP: 70-02-53/00 and higher
Fixed Product/Version SVP: 70-02-77/00
Category Performance Manager
Changed Part SVP

HDS Confidential 4 of 8
8 Failure of resync operation for UR for Mainframe pair
Phenomena A resync operation for a UR for Mainframe pair that used 3390-A failed
with SSB=8F78 output. At the time, SSB=D996 was output on RCU side.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) Universal Replicator for Mainframe
(2) Emulation type is 3390-A.
(3) Volumes whose volume size falls into the following ranges are used.
7792Cyl to 8183Cyl, 15583Cyl to 16366Cyl, 23374Cyl to 24550Cyl,
32278Cyl to 32733Cyl, 40069Cyl to 40917Cyl, 47860Cyl to 49100Cyl,
56764Cyl to 57284Cyl, 64555Cyl to 65467Cyl, 72346Cyl to 73651Cyl,
81250Cyl to 81834Cyl, 89041Cyl to 90018Cyl, 96832Cyl to 98201Cyl,
105736Cyl to 106385Cyl, 113527Cyl to 114568Cyl, 121318Cyl to
122752Cyl, 130222Cyl to 130935Cyl, 138013Cyl to 139118Cyl,
145804Cyl to 147302Cyl, 153595Cyl to 155485Cyl, 162499Cyl to
163669Cyl, 170290Cyl to 171852Cyl, 178081Cyl to 180036Cyl,
186985Cyl to 188219Cyl, 194776Cyl to 196403Cyl, 202567Cyl to
204586Cyl, 211471Cyl to 212770Cyl, 219262Cyl to 220953Cyl,
227053Cyl to 229137Cyl, 234844Cyl to 237320Cyl, 243748Cyl to
245504Cyl, 251539Cyl to 253687Cyl, 259330Cyl to 261870Cyl
Affected Products/Version DKCMAIN: 70-02-54-00/00 and higher
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Universal Replicator for Mainframe
Changed Part DKCMAIN

9 Link-down on all ports of CHT/CHG PCB


Phenomena During post-processing for an MPB failure, link-down occurred in all
ports of mounted CHT/CHG PCBs. At the completion of post-processing,
SSB=B6FB or B6F3 was output.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) CHT/CHG PCBs are installed.
(2) An MPB failure occurs.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Open
Changed Part DKCMAIN

10 Failed to recover the blocked MPB after replacement


Phenomena When a failure occurred in an MPB and the MPB was blocked, the
blocked MPB was replaced but the blockage could not be recovered.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) An ownership is being migrated.
(2) A failure occurs in the ownership migration source MPB and the MPB
is blocked.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Open or Mainframe
Changed Part DKCMAIN

HDS Confidential 5 of 8
11 CHK3 with SSBs output during Mainframe I/O processing
Phenomena During Mainframe I/O processing, CHK3 occurred and SSB=35A0 and
160F were output. (In rare cases, WCHK1 occurred and SIM=3073xx
was output.)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur during Mainframe I/O processing.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Mainframe
Changed Part DKCMAIN

12 Operation failures
Phenomena Any of the following phenomena might occur.
(1) PS OFF was disabled and SIM=388F00 was output.
(2) MPB replacement failed and SVP message ONL2788E was output.
(3) MPB removal failed and SVP message ONL2788E was output.
(4) Parity group migration in a CLPR failed.
(5) Cache maintenance (replacement, installation, removal) failed and
SVP message ONL2788E was output.
(6) An I/O to an LDEV that was a target of following operations turned
time-out by an operation accompanied with LDEV ownership migration
(such as MPB maintenance/ failure, LUSE connection/release, SI pair
creation/release, Snapshot pair creation/deletion, JNL VOL
addition/deletion, ownership migration by CCI/Storage Navigator).
Severity (High, Medium, Low) Low
Conditions of Occurrence Problem may occur when any of the following operations is performed.
(1) PS OFF
(2) MPB replacement
(3) MPB removal
(4) Parity group migration in CLPR
(5) Cache maintenance (replacement, installation, removal)
(6) An operation with ownership migration such as MPB
maintenance/failure, LUSE connection/release, SI pair creation/release,
Snapshot pair creation/deletion, JNL VOL addition/deletion, and
ownership migration by CCI/Storage Navigator.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Open or Mainframe
Changed Part DKCMAIN

13 Wrong Object ID returned by GET of standard MIB


Phenomena A value returned by GET (sysObjectID 1.3.6.2.1.1.2.0) of standard MIB
(Management Information Base) in SNMP was not the Hitachi Object ID
(1.3.6.1.4.1.116.3.11.4.1.1) Microsoft Object ID (1.3.6.1.4.1.311.1.3.1.1)
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when standard MIB is obtained.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-77/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 6 of 8
14 SSB=3289/A443 output and blockage of HDD port/HDD/ECC
Phenomena The following phenomena might occur:
- SSB=3289 and A443 were output due to CHK2.
- If above phenomena frequently occurred, HDD ports might be blocked.
- If both of HDD ports were blocked, the HDD was blocked.
- If multiple HDDs within an ECC were blocked, the ECC was blocked.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when an LDEV defined on an SATA-E HDD is
used.
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Open or Mainframe
Changed Part DKCMAIN

15 Unable to select 40 or higher CU#, or operation failure


Phenomena During LDEV creation from Storage Navigator, the following occurred.
Phenomenon 1: 40 and higher CU numbers could not be selected.
Phenomenon 2: If 40 or a higher CU number was selected, Storage
Navigator message 3305-001074 was output and the operation failed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
Phenomenon 1:
(1) SM is installed with "64KLDEV/SI/VM Extension1/
FCv2/FCSE/DP/CoW/TPF" of SM function checked.
(2) An LDEV is installed by VLL function of Storage Navigator.
Phenomenon 2:
(1) SM is removed with "64KLDEV/SI/VM Extension1/
FCv2/FCSE/DP/CoW/TPF" of SM function unchecked.
(2) An LDEV of CU number 40 or higher is installed by VLL function of
Storage Navigator.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-77/00
Category Storage Navigator
Changed Part SVP

16 Unable to receive failure logs due to deadlock


Phenomena Due to a deadlock in a background task during SVP online micro-
program exchange, a pop-up window of "Wait.. Ending Background
Task" remained displayed and no progress was made, which led to
receiving module being unable to receive failure logs such as SIM.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem may occur in rare cases when a deadlock occurs between
failure information receiving module and SIM display window due to a
conflict between message transfer processing to SIM display window
executed every 10 seconds by the failure information receiving module
and logging off from SVP.
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-77/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 7 of 8
17 No action code displayed on SVP
Phenomena SIM=307600 was output and the action code was not displayed on SVP.
Severity (High, Medium, Low) Low
Conditions of Occurrence The problem occurs when SIM=307600 is output. (When FM SUM value
error is detected by periodical diagnosis due to a FM failure in MPB.)
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-77/00
Category Open or Mainframe
Changed Part SVP

18 MP blockage with SSB=1644 output


Phenomena With external path blocked, an MP was blocked with SSB=1644 output.
Severity (High, Medium, Low) Low
Conditions of Occurrence Unknown
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Open
Changed Part DKCMAIN

19 ABEND of LDEV format due to CHK3/WCHK1


Phenomena During Mainframe LDEV format processing, CHK3 (SSB=160F) or
WCHK1 (SSB=32FE) occurred and the format could not be completed.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem may occur when all the following conditions are met.
(1) Mainframe environment
(2) Multiple Mainframe LDEVs belong to the same MPB.
(3) A host I/O is being processed to the above LDEVs (as stated in (2)).
(4) LDEV Format is performed at the above LDEVs (as stated in (2)).
(5) A failure reset (CHK3, CHK1B, CHK4 or hang-up reset) occurs, or
WCHK1 MP blockage(s) occur at some MPs (not all the MPs) in the
above MPB (as stated in (2)).
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 70-02-80-00/00
Category Mainframe
Changed Part DKCMAIN
20 Incorrect capacity of CVS volume
Phenomena During RAID group installation, if a CVS VOL was created with Block
and Division free space by number specified, a VOL in unexpected size
was created.
Severity (High, Medium, Low) Medium
Conditions of Occurrence The problem occurs when all the following conditions are met.
(1) A CVS VOL is created with Block and Division free space by number
specified at an operation of Define Configuration & Install, RAID group
installation, or Make Volume from SVP.
(2) The capacity of volume created by the above operation is "free
space/specified division number > 1.999TB (4294967295 blocks)".
Affected Products/Version SVP: All
Fixed Product/Version SVP: 70-02-77/00
Category Open or Mainframe
Changed Part SVP

HDS Confidential 8 of 8