Sunteți pe pagina 1din 1

Cleanroom Cleaning Procedures

Establish a Cleaning Protocol

The Institute for Environmental Vacuuming or tack rolling The second vacuuming removes
Sciences preferred Cleanroom should be used to pull loose loosened particles and cleaner
cleaning Protocol can be summed particles from surfaces. Wiping residues. It is a method tested
up in three words: provides mechanical energy to over time to be most reliable
remove more tightly bound and can be applied to most
Vacuum, Wipe, Vacuum. particles and cleaning solutions general Cleanroom cleaning
break the surface tensions and applications
reduce adhesion forces.

Step 1 3 Ceiling Panels Step 2 3 Light Fixtures Step 3 3 HEPA Filters


Vacuum with a soft brush Vacuum horizontal surfaces Use extreme caution not to
attachment. with a soft brush attachment. contact HEPA filter.
Wipe gently in a single direction Wipe surfaces of egg crate light Vacuum with a soft brush
using slightly overlapping diffusers with a woven polyester attachment.
strokes. wipe dampened with DI water. Wipe horizontal surfaces of egg
Tack roll in a single direction, Open unit. Wipe bulbs. Vacuum crate diffusers with a woven
again using slightly overlapping horizontal surfaces with soft polyester wipe dampened with
strokes. brush attachment. DI water.
Remove spots with a commercial Close unit. Wipe trim pieces. Vacuum with a soft brush
cleaner, DI water and a polyester attachment. Wipe trim pieces.
wiper.
Vacuum with a soft brush
attachment

Step 4 3 Sprinkler Heads Step 5 3 Walls


Gently wipe exposed surfaces Vacuum with a soft brush Mop from top to bottom using
only with a woven polyester wipe attachment. slightly overlapping strokes.
dampened with DI water. Wipe with a woven polyester Use a minimum of liquid to avoid
Use extreme caution not to wipe dampened in a 16:1 splashing or dripping
activate. solution of DI water and a Tack roll from top to bottom.
commercial cleaning detergent. Remove spots with a commercial
Wipe in one direction only using cleaner and woven polyester
slight overlapping strokes. wipe.
Mop entire surface with a Vacuum with a soft brush
commercial wall cleaning system. attachment

Step 6 3 Glass Surfaces Step 7 3 Piping & Process Equipment


Squirt commercial glass cleaner Consult with a process engineer; Wipe top to bottom whenever
on woven polyester wipe. group leader or equipment possible, using slightly
Apply to surface with a operator prior to cleaning any overlapping strokes..
dampened wipe. Squeegee (from process equipment. Use a minimum of liquid on
top to bottom if on a vertical Clean only exterior surfaces. Do wipes.
surface) to remove excess liquid. not clean in or near processing Wipe from top to bottom and
Wipe with a dry woven polyester areas. avoid any splashing or dripping
wipe. Use wipes damped with solution of cleaning solution.
of IPA and commercial cleansers. Vacuum with a soft brush
First vacuum with a soft brush attachment.
attachment.

Step 8 3 Floors

Vacuum surface. The rinse water should be left Failure to change the water on a
Wash floor with a 16:1 solution on the floor long enough too regular basis can lead to cross
of DI water and a floor cleanser completely saturate any film contamination, dragging
using a clean, non3 build3up. potentially damaging
contaminating mop head. Then the rinse water should be contamination from one area to
Rinse with DI water and a new, mopped up, making sure to the next.
clean non3particulating mop change the water after mopping After the floor is dry, it should
head every 10 to 15 square feet of be vacuumed.
floor surface.
The water change is critical to
the operation.

122 F Commerce Park Drive, Barrie, ON L4N 8W8, Canada