Known Parameters :

Height of earth Retained, h = 3 m


Unit weight of soil = 19 kN/m2
Unit weight of concrete = 25 kN/m2
angle of internal friction of soil, φ = 30°
Slope of backfill, β = 25°
soil-wall interface friction, δ = 25°
Surcharge pressure on backfill, ws = 0 kN/m2

Wall Dimensions :

Assumed depth of foundation, d = m


Total height of the wall, H = m
Safe Bearing Capacity of soil = kN/m2

Thickness of base slab, t = mm


Thickness of stem at base = mm
Thickness of stem at top = mm

3 of 6 24-12-2019, 17:51
Cantilever Retaining Wall Design http://www.iitg.ac.in/amurali/CWdesign/design.php?step=9

Seismic earth Pressure analysis :

Lateral Earth Pressure Coefficients (Mononobe-Okabe's)

Coefficient Seismic Static

Active NAN 0.504

Passive 2.604 3

Lateral Earth Pressures and distance of their point of application from bottom
of the base footing

Surcharge Soil

Net seismic force NAN NAN

Static component 0 kN @ 2.338 m 104.696 kN @ 1.559 m

dynamic component NAN kN @ 3.086 m NAN kN @ 2.338 m

Resultant pressures at the base and moment of forces about the bottom of the heel.
weight and moment calculations

4 of 6 24-12-2019, 17:51
Cantilever Retaining Wall Design http://www.iitg.ac.in/amurali/CWdesign/design.php?step=9

Reinforcement Design :

eccentricity of vertical reaction from CG of design


Reinforcement footing,calculations
e = NAN m

Toe Heel Stem


/m2 is less than safe bearing capacity
Effective thickness, (mm) 264 264 262
o
2
Design shear force, (kN/m) kN/m . So, no tension
81.698 58.793at base74.535

Nominal Shear stress, (MPa) 0.309 0.22 0.28


C
Design Moment, (kNm/m) 52.872 51.546 105.984
F
S Required % of steel for shear 0.19 0.12 0.18

A shear-key has %
Required been provided
of steel to balance the sliding
for flexure 0.22 force: 0.21 0.46
D
Area of steel required, (mm2/m) 580.8 554.4 1205.2
W
D Maximum spacing allowed, (mm) 195 204 167
Passive resistance provided by shear key = 57.48 kN
Factor of safety against sliding, FSsliding = NAN