SILO D-PUMP
1. Equipment Technical Details:
D-pump is the conveying vessel. This is used for fly ash conveying form intermediate silo (6000t)
to silo (50000t).
2. Pre-checks and Action By Field Engineer
Ensure fluidizing blower, IAC in running condition.
Ensure dome valves working properly.
Ensure D-pump inlet MIV is open condition.
Ensure silo vent fan and pulse jetting is working.
Ensure Silo selection dump valves are operate properly and are in auto mode.
Check the availability of STAC.
3. Operating Procedure:
Start the selected STAC and start the line flushing.
Select the D-pump conveying in auto mode.
Check the dome valves operation and seal pressure (>5.5 kg/cm2).
Check the fluidizing of D-pump.
Ensure the blower heater temperature ok.
Check the conveying is going properly.
Frequently check the conveying pressure (2.3 kg/cm2).
For any abnormalities record logbook and inform shift in-charge.
PHYSICALLY CHECK BOTTOM ASH HOPPER AFTER OPENING THE MAN HOLE
DOOR AS LIKE FOREIGN MATERIAL AFTER THAT CHECK THE ROTATION OF
CLINKER GRINDER IN FORWARD AND REVERSE DIRECTION.
CHECK THE OIL LEVEL FREENESS.
PHYSICALLY ALL VALVE CHECKING MANUALLY OPERATION THROUGH PLC
AS WELL.
FIRST ENSURE SLURRY AND ASH WATER SUMP CLEANING AND THEN FILL
THE SUMP.
CHECK THE SEAL PRESSURE OF ALL DOME VALVE PHYSICALLY.
CHECK THE LINE VACUUM AND SHUT OFF VACUUM OF ALL PASSES.
CHECK FLUIDIZING BLOWER AIR OF INDIVIDUAL HOPPER.
CHECK THE PURZING OF BUFFER HOPPER AND SILO BAG FILTER.
IF ANY PROBLEM OBSERVED IN EQUIPMENT THEN INFORM TO SHIFT IN
CHARGE/ OPERATION IN CHARGE IMMEDIATLY.