P R OT E C T I O N

MiCOM P891
Circuit Breaker
Trip / Close Module

P891 is suitable for application with protection relays where


relay independent tripping and closing functionality is
desired.

Independent circuit breaker indication is provided by two


LEDS allowing for direct wiring of the circuit breaker's 52A
and 52B contacts. With the wide voltage supply range
capability, integration into any battery supply system is
simple.

Configure the module to integrate with feeder management


relay functions such as autoreclosing and check
synchronizing and provide a secure CB control solution.

Pushbutton covers are provided to prevent inadvertent


operation of pushbutton switches. This safety feature allows
the module to be used under the most stringent operating
procedures. These covers can also be removed if not
required.

Customer Benefits
• Control to suit
customers' operational
procedures.
• Simple and robust
design
• Clear status indication

AREVA T&D
APPLICATION HARDWARE DESCRIPTION

The MiCOM P891 Trip/Close module can be applied to The module is housed in a 10TE Midos Case, suitable
directly control a circuit breaker or other plant such as for either rack or panel mounting. Pushbuttons can be
motorised line isolator switches requiring fitted with color coded push button covers and these
open(trip)/close control. can be locked by the user by means of a padlock or
other suitable locking device.
> Typical Application
> Features
The application shows the P891 combined with the
P14x and P991 to provide a complete feeder scheme • Close and Trip pushbuttons
solution. The P891 provides relay independent tripping • Red and Green LED indication for device open
and closing functionality. This functionality can also be and close indication
integrated with the protection relay to make use of relay • Universal power supply for LED indication circuit
functions such as check synchronising or
• Two N/O output contacts per pushbutton
autoreclosing.
• Removable Pushbutton covers(optional)
• ANSI Labelling

Fig.1 Typical scheme application

+ Close + Trip
52A 52B
T P991 P14x P891

2 1 2
Va
Close – – Trip 2 3 4
Vb
2 5 6
Vc Close PB
2 7 8
1 9 10 Trip
Input
1 11 12 CB Closed
+ Trip
8 13 14 A
9 15 16
8 17 18 B
Trip PB
9 19 20
8 21 22 C
9 23 24
Input
8 25 26 N CB Open
9
27 28

29 30 SEF

31 32
Shorting
Bars

Use MICOM P891


for secure control
of circuit breakers.
2>3
OUTPUT CONTACTS PRODUCT USE

> Standard Contacts The P891 output contacts are designed to be wired
directly into control circuits. However care should be
taken so that the Pushbutton output contact break
General purpose output contacts for signalling, tripping
capacity is not exceeded. In the case of circuit breaker
and alarming.
applications, the breaker's auxiliary contacts are used
to interrupt the trip/close circuit current once the
> Contact Ratings
breaker is operated.
• Make & Carry 3Amps for 3s
• Carry 250 A dc for 30ms
10 A continuous INSTALLATION
• Break DC: 50W resistive
DC: 62.5W inductive The generic safety guide SFTY/4L M/B11 should be
(L/R = 50ms) read before installing or using the P891 Trip/Close
AC: 2500VA Module.
AC: 2500VA inductive
(P.F. = 0.7)
EMC COMPLIANCE
• Maxima 10A and 300V
Compliance with the
• Loaded contact 10,000 operations minimum
89/336/EEC European Commission
• Unloaded contact 100,000 operations minimum
Directive on EMC

PRODUCT SAFETY Compliance with the


LED INPUTS
European Commission
73/23/EEC Low voltage directive
> Voltage Ratings

• DC operative range 19-300V dc P891 THIRD PARTY COMPLIANCES


• AC operative range 24-265V rms, 50/60Hz
File Number : E202519
C UL
fi US Original Issue Date : 18-01-2005
(Complies with Canadian and
US requirements)

Figure2 P891 connection detail and rear terminal block detail

CASE EARTH
2

RED LED
4
AC or DC
VX Aux Supply
4

VAUX 6
RED LED
6

RED 1
8
8

RED RED 1
10
10

PUSHBUTTON

RED 2 12
12

RED 2
14
14
16

VAUX GREEN LED


16
GREEN LED AC or DC
18

VX Aux Supply
18
GREEN 1
20
22

20

GREEN 2 GREEN 1
24

22
GREEN
PUSHBUTTON
24
26

GREEN 2
26
28

MiCOM P891

Compact case size, for easy mounting alongside


MIDOS and MiCOM protection relays
DEVICE TRACK RECORD-SWITCH MODULES
>> MMLZ - Auxiliary modules used in multiple hardwired scheme
applications since 1989.
>> Complements MIDOS and MiCOM relays, plus MMLG and
P99x test blocks.

MiCOM is a registered trademark of AREVA. All trade names or trademarks mentioned herein whether registered or not, are the property of their owners. - 389191982 RCS PARIS - Printed in France - SONOVISION-ITEP
AUTOMATION-L3-P891-BR-03.05-0847-GB - © - AREVA - 2005. AREVA, the AREVA logo and any alternative version thereof are trademarks and service marks of AREVA.

AREVA T&D Worldwide Contact Centre: Our policy is one of continuous development. Accordingly the
http://www.areva-td.com/contactcentre/ design of our products may change at any time. Whilst every
effort is made to produce up to date literature, this brochure
Tel.: +44 (0) 1785 250 070 should only be regarded as a guide and is intended for
information purposes only. Its contents do not constitute an offer
for sale or advise on the application of any product referred to in
www.areva-td.com it. We cannot be held responsible for any reliance on any
decisions taken on its contents without specific advice.
www.areva-td.com/protectionrelays

S-ar putea să vă placă și