Version: 1.0
Last Update Date: 2018-06-06
Last Update By: Muruganandham T
1
Physical Damage Case
In general, physical damage is caused by misuse, accident, modification, unsuitable physical or operating environment or improper
maintenance. Some common physical damage case will be shown as follow. Frontline can use this for reference to classify the physical damage
case since those cases will be not covered by Base Warranty service.
1. Obvious CID Issue as per CID Guideline (Not apply for New / Open Box Machine)
a. Crack / Gap / Pressure / Leakage / Damage Issue - Action needed from Vendor before escalate to Lenovo Technical team:
Step 1: Identifying CID – Check Servicer Tips / Any QI or Known Issue found?
Answer: If Yes, proceed with QI. Else, go to Step 2. Unless, customer reported >3 machines with same symptoms then Vendor
should escalate to Lenovo Technical team.
Step 2: Machine covered under a TPP / ADP warranty upgrade?
Answer: If yes, please make sure symptom reported is covered under TPP / ADP. Else, inform customer that the symptoms
reported will not be covered under Base Warranty or TPP/ ADP warranty and ask them how they wish to proceed.
2. Mechanical Part (Verify with CID Guidelines before escalate to Lenovo Technical Team)
b. Part Required: Palm rest / Keyboard Bezel / Keyboard
During Vendor Engineer onsite: If engineer onsite found that there is CID, then Vendor should not replace for customer
3. Lenovo supports CID parts replacement for functional failure case, Only if the failure symptom is not caused by/related to CID area.
2
Contents
Physical Damage.1-Abrasion/Scratch/Nicks [S] ............................................................................................................................................. 4
3
Physical Damage.1-Abrasion/Scratch/Nicks [S]
Issue Introduction
LP1 Abrasion/Scratch No Display / Lines on Display / Damage possibly caused due: Follow repairable/un-repairable instruction.
/Nicks Blur Display / Flickering Issue / 1. Improper handling of tools,
Abnormal Color on Display 2. Incompatible screws/connectors using Follow cosmetic criteria for CID cosmetic
excessive force inspection
3. Improper transportation or packaging
4. Physical damage caused secondary
damage on part, e.g., machine drop,
distort, mixed etc.
4
HP1 Abrasion/Scratch HDD Error in POST / Can’t Damage possibly caused due: Follow repairable/un-repairable instruction.
/Nicks Detect HDD while POST / 1. Improper handling of tools,
Abnormal Noise from HDD / 2. Incompatible screws/connectors using Follow cosmetic criteria for CID cosmetic
Bad Sector excessive force inspection
3. Improper transportation or packaging
4. Physical damage caused secondary
damage on part, e.g., machine drop,
distort, mixed etc.
5
Visual Explanations for Each Code
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
S1 System Yes
CID
Board and
Circuit [S1C] [S1A]
S2 System Yes
Non-CID, if shape is completely fit
CID
Board
Screw CID as original screw, alert tech team [S2C] [S2A]
Holes/Locati
on Holes
6
S3 External Connectors CID Yes
Scratch
Abrasion
[S3C] [S3A]
7
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
S7 Chipsets(Includi CID No
ng Internal Damage
CPU,GPU,ROM, [S7C]
BIOS chips, I/O [S7R]
chips, and
other ICs)
Scratch
8
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LP1-SH LCD Panel Surface Yes
CID
[LP1SHC] [LP1SHA]
9
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Deep Scratches
10
Physical Damage.2-Crack/Break/Distortion/Disposition/Part Missing [D]
Issue Introduction
Issue CID Phenomenon Reported Issue Issue Causes Notes
Code
D Cracks/Break/Dispo Machine Cant Power On / Hang Damage possibly caused due: Follow repairable/un-repairable instruction.
1,3,4,6,7, sition/Distortion/P or Crash at Lenovo POST / Blue 1. Improper handling of tools,
8 art Missing. Screen (BSOD) / Battery Charge 2. Incompatible screws/connectors using Follow cosmetic criteria for CID cosmetic
Including smash Failure /Display, keyboard, excessive force inspection
and bump corners, connectors not function, etc. 3. Improper transportation or packaging
soldering pad and 4. Machine physical damage caused
component secondary damage of parts, e.g., drop,
missing, etc. distort, etc.
LP2 Liquid Leakage / No Display / Lines on Display / Damage possibly caused due: Follow repairable/un-repairable instruction.
Internal Cracked/ Blur Display / Flickering Issue / 1. Improper handling of tools,
LCD Pressing Abnormal Color on Display 2. Incompatible screws/connectors using Follow cosmetic criteria for CID cosmetic
Damage/ Broken excessive force inspection
LCD Panel/ Damage 3. Improper transportation or packaging
Mylar/ Damage / 4. Machine physical damage caused
Missing Hinge/ secondary damage of parts, e.g., drop,
Damage LCD distort, etc.
Assembly/ Damage
LCD Cable
11
KP2 Keyboard Keys Posting Error 021x / Keyboard Damage possibly caused due: Follow repairable/un-repairable instruction.
Broken or Key’s Not Responding / Erratic 1. Improper handling of tools,
Damaged/ Mouse Movement Touchpad / 2. Incompatible screws/connectors using Follow cosmetic criteria for CID cosmetic
Keyboard Cable TrackPoint or Mouse Not excessive force inspection
Broken Responding / Caps Lock 3. Improper transportation or packaging
Indicator No Longer Appears / 4. Machine physical damage caused
Touchpad or TrackPoint Button secondary damage of parts, e.g., drop,
Not Responding / Key Stuck or distort, etc.
Sticky
TP2 Touchpad Button Posting Error 021x / Keyboard Damage possibly caused due: Follow repairable/un-repairable instruction.
or Surface Peel Off Key’s Not Responding / Erratic 1. Improper handling of tools,
/ Wear Off Mouse Movement Touchpad / 2. Improper transportation or packaging Follow cosmetic criteria for CID cosmetic
TrackPoint or Mouse Not 3. Machine physical damage caused inspection
Responding / Caps Lock secondary damage of parts, e.g., drop,
Indicator No Longer Appears / distort, etc.
Touchpad or TrackPoint Button
Not Responding / Key Stuck or
Sticky
HP2 Component / HDD Error in POST / Can’t Damage possibly caused due: Follow repairable/un-repairable instruction.
Connector Damage Detect HDD while POST / 1. Improper handling of tools,
or Dented / HDD Abnormal Noise from HDD / 2. Incompatible screws/connectors using Follow cosmetic criteria for CID cosmetic
Screw Loose or Bad Sector excessive force inspection
Missing / 3. Improper transportation or packaging
Damaged Screw 4. Machine physical damage caused
Hole / Cover secondary damage of parts, e.g., drop,
Dented distort, etc.
12
CP2 Machine Crack on mechanical parts / Damage possibly caused due: Follow repairable/un-repairable instruction.
Unintentional Hinge loose / screw loose 1. Improper handling of tools,
Drops and Bumps / 2. Incompatible screws/connectors using Follow cosmetic criteria for CID cosmetic
Cosmetic Damage excessive force inspection
3. Improper transportation or packaging
4. Machine physical damage caused
secondary damage of parts, e.g., drop,
distort, etc.
PP2 AC Adapter Cable Machine Cant Power On / Damage possibly caused due: Follow repairable/un-repairable instruction.
Broken / Internal Hang or Crash at Lenovo 1. Improper handling of tools,
Cable Broken POST / Blue Screen (BSOD) / 2. Incompatible screws/connectors using Follow cosmetic criteria for CID cosmetic
Battery Charge Failure / excessive force inspection
Battery loose 3. Improper transportation or packaging
4. Machine physical damage caused
secondary damage of parts, e.g., drop,
distort, etc.
13
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
D1 System Board Yes
Smash Corner CID
and Circuit
[D1C] [D1A]
Board Distortion
14
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
D4 Internal Sockets CID
& Brackets Yes
[D4C]
[D4A]
* Engineer should
Cracks
dismount the FRU parts
Cracks in gentle with care,
Count as SID case if it is
a return part.
Distortion
Disposition
Cracks
15
Yes
CID
[D3A]
[D3C]
External
D3 connectors
Yes
CID
[D6A]
[D6C]
Switches &
D6
Buttons
Distortion
16
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
D7 Chips (Including
CID
CPU,GPU,SB,NB, No
BIOS chips, I/O [D7C]
chips, and other Internal Damage
ICs)
[D7A]
17
D8 Components Yes
CID
(Including
[D8A]
capacitors, [D8C]
resistors,
inductance,
MOS, etc.) Crack
Part Missing
Part Missing
Distortion
Crack
PAD damaged
18
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LP2-CK LCD Panel - Yes
CID
Liquid Leakage /
Internal Cracked [LP2CKC] [LP2CKA]
19
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LP2-PD LCD Panel - Yes
LCD Pressing Damage CID
LCD Pressing
Damage [LP2PDC] [LP2PDA]
How it happen: 20
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LP2-BP LCD Panel - Yes
CID
Broken LCD Broken Glass on edge
Panel [LP2BPC] [LP2BPA]
21
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LCD Panel Yes
CID
Mylar -
Damage Mylar, [LP2DMC] [LP2DMA]
LP2-DM Missing/Without
Mylar
Damaged Mylar
Damaged Mylar
22
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LCD Panel Yes
CID
Mylar -
Damage Hinge, Damaged Hinge [LP2DHC] [LP2DHA]
LP2-DH Missing/Without
Hinge
Damaged Hinge
23
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LCD Panel Yes
LCD Cover Forced Open CID
Assembly -
LCD Cover [LP2DAC] [LP2DAA]
LP2-DA Forced Open /
Hinge Broken
Off / LCD
Cover Dented
Hinge Broken Off
24
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LCD Panel Cable - No
CID
Damage LCD Intentional damage
Cable [LP2DCC]
LP2-DC [LP2DCR]
Note:
Broken LCD cable in
LCD Assembly which
is not possible to
touch / break it, and
Broken LCD Cable
this should consider
as CID (customer
damage it) / SID
(may due to the
careless engineer)
25
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Battery Yes
CID
26
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Battery Yes
CID
Attention:
Need to handle
carefully since
sometime may
relate to safety
issue.
Battery Broken
27
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Ethernet (LAN) Port Yes
CID
EP2-LB Covered for single
Broken Ethernet [EP2LBC] case (Unintentional
Port Latch drops and bumps)
[EP2LBA]
Note:
Please alert
technical team if
batch issue found.
28
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Keyboard Yes
CID
KP2-CI
Keys broken / wear [KP2CIC] [KP2CIR]
off / foreign
materials cause ***NOTE:
malfunction / other If more than 1 case
cosmetic issue reported /
complaints by
GA/KA, kindly
inform Lenovo Tech
Keys Broken or Damaged
Team.
29
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Keyboard CID No
KP2-CB Internal Damage
[KP2CBC]
Keyboard Cable [KP2CBR]
Broken
Remark:
Broken Keyboard cable
in Keyboard Assembly
which is not possible
to touch / break it, and
this should consider as
Keyboard Cable Broken
CID (customer damage
it) / SID (may due to
the careless engineer)
30
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Touchpad CID Yes
TP2-BS
Touchpad Button [TP2BSR]
[TP2BSC]
or
Touchpad Surface
31
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Hard drive CID No
HP2-CD Internal Parts
[HP2CDC]
Component /
Connector Damage [HP2CDR]
or Dented
32
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Hard drive Screw / CID No
HP2-SC Screw Hole Internal Damage
[HP2SCC]
HDD Screw Loose
[HP2SCR]
33
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Hard drive CID No
HP2-DH Base Dented Internal Damage
[HP2DHC]
Dented or Hole
[HP2DHR]
Corner Dented
Hole in Cover
34
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LCD Bezel Yes
CID
CP2-LB
LCD Bezel Crack [CP2LBC] [CP2LBA]
Note:
Please alert technical team if
batch issue found.
35
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LCD Lock
CID
CP2-LL Yes
LCD Lock Broken
[CP2LLC]
[CP2LLA]
Note:
Please alert technical team if
batch issue found.
36
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Base Cover Yes
ADP Accept, affecting structure CID
CP2-BC
[CP2BCC] [CP2BCA]
Note:
Please alert technical team if
batch issue found.
37
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Keyboard bezel / Yes
CID
CP2-KP Palm rest
[CP2KPC] [CP2KPA]
Note:
Please alert technical team
if batch issue found.
38
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
External Port of Yes
CID
CP2-EP Cover
[CP2EPC] [CP2EPA]
Note:
Please alert technical team
if batch issue found.
39
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Bezel / Cover No
SID
CP2-SH
[CP2SHC] [CP2SHR]
Note:
Please alert technical team
if batch issue found.
40
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Base Cover Yes
CID
CP2-FM Covered for single case
Footer missing [CP2FMC] (Unintentional drops and
bumps)
[CP2FMA]
Footer missing No
Not Covered for batch
issue (Improper
Maintenance / Damage
from intentional misuse)
[CP2FMR]
Note:
Please alert technical team
if batch issue found.
41
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Power Cable Yes
CID
[PP2PCC] [PP2PCR]
PP2-PC
Note:
Please alert technical team
if batch issue / BURN case
found.
42
Physical Damage.3-Pin Damage [P]
HP3 Pin Damage, HDD Error in POST / Can’t Damage possibly caused due: Follow
Including Pin Detect HDD while POST / 1. Improper handling of tools, repairable/un-repairable
bent, missing, Abnormal Noise from HDD / 2. Incompatible screws/connectors using excessive force instruction.
broken, etc. Bad Sector 3. Improper transportation or packaging
4. Machine physical damage caused secondary damage of Follow cosmetic criteria for
parts, e.g., drop, distort, etc. CID cosmetic inspection
43
Mechanical Part on Board-MM
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
P4 CPU Socket No
Pin Bent CID/SID
Internal Damage
[P4A]
[P4C]
Pin Bent
44
Mechanical Part on hard drive
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
Hard drive No
CID
HP3-PB connector Internal Damage
[HP3PBC]
Drive Pin Bent [HP3PBR]
Or
PIN Raised
PIN Raised
45
Chemical Damage.1- Oxidation/Liquid Spillage/Mold/Corrosion/ [C]
Issue Introduction
Issue CID Reported Issue Issue Causes Notes
Code Phenomenon
C Oxidation Machine Can’t Power Damage possibly caused due: Follow repairable/un-repairable
1,3,4,5,6, /Liquid spillage/ On / Hang or Crash at a) Improper handling of PC, e.g. liquid spill instruction.
7,8 Mold & Lenovo POST / Blue b) Caused by a failure to follow specification requirements
Corrosion Screen (BSOD) / regarding usage, storage or transportation of the product. Follow cosmetic criteria for CID
Battery Charge Failure Example: Product usage/storage/transportation in a condition cosmetic inspection
/Display, keyboard, that exceeds the values specified in the user manual
connectors not (Humidity, Temperature, Dust, Air Pollution etc.)
function, etc.
LC1 Oxidation No Display / Lines on Damage possibly caused due: Follow repairable/un-repairable
/Liquid spillage/ Display / Blur Display a) Improper handling of PC,e.g. liquid spill instruction.
Mold & / Flickering Issue / b) Caused by a failure to follow specification requirements
Corrosion Abnormal Color on regarding usage, storage or transportation of the product. Follow cosmetic criteria for CID
Display Example: Product usage/storage/transportation in a condition cosmetic inspection
that exceeds the values specified in the user manual
(Humidity, Temperature, Dust, Air Pollution etc.)
46
KC1 Keyboard Posting Error 021x / Damage possibly caused due: Follow repairable/un-repairable
Oxidation Keyboard Key’s Not a) Improper handling of PC,e.g. liquid spill instruction.
/Liquid spillage/ Responding / Erratic b) Caused by a failure to follow specification requirements
Mold & Mouse Movement regarding usage, storage or transportation of the product. Follow cosmetic criteria for CID
Corrosion Touchpad / TrackPoint Example: Product usage/storage/transportation in a condition cosmetic inspection
or Mouse Not that exceeds the values specified in the user manual
Responding / Caps (Humidity, Temperature, Dust, Air Pollution etc.)
Lock Indicator No
Longer Appears /
Touchpad or
TrackPoint Button Not
Responding / Key
Stuck or Sticky
47
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
C1 Board and Circuit Yes
CID
[C1A]
[C1C]
Corrosion
PCB Corrosion
48
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
C4 Internal Yes
CID
Sockets;
[C4A]
Internal [C4C]
Brackets;
Card readers
internal
connector
Corrosion Rust
C3 External Yes
CID
Connectors
[C3C]
[C3R]
Rust Rust
49
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
C7 Chipsets (Including Yes
CID
chips, silicon, ICs)
[C7A]
[C7C]
Corrosion
C8 Components Yes
CID
(Including Rust
[C8A]
capacitors, [C8C]
resistors)
Corrosion
50
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LC1-PB Board and Yes
CID
Circuit
[LC1PBA]
[LC1PBC]
51
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LC1-MI LCD Panel / LCD Yes
CID
Assembly / LCD
Module – Screw [LC1MIC] [LC1MIA]
Spots; Edge of
LCD; Internal
Sockets;
Internal
Brackets;
internal
connector
Rusty happened on screw Spots
52
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
KC1-LS Keyboard Yes
CID
[KC1LSA]
Liquid Spill [KC1LSC]
53
Chemical Damage.2-Burn/Charred/Explode [B]
Issue Introduction
Issue CID Reported Issue Issue Causes Notes
Code Phenomenon
B Burn/Charred/E Machine Cant Power Damage possibly caused due: Follow repairable/un-repairable instruction.
1,3,4,7,8 xplode/Bubbled On / Hang or Crash at a) Improper handling of PC, e.g. liquid spill,
Lenovo POST / Blue frequently hot plug/unplug, etc. Follow cosmetic criteria for CID cosmetic
Screen (BSOD) / Battery b) Caused by a failure to follow specification inspection
Charge Failure /Display, requirements regarding usage, storage or
keyboard, connectors transportation of the product. Example: Product
not function, etc. usage/storage/transportation in a conditions that
exceed the values specified in the user manual
(Humidity, Temperature, Dust, Air Pollution etc.)
54
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
B1 Board and CID Yes
Circuit [B1C]
[B1A]
Claim as CID if BATCH claims
burned/charred components
or Integrated Circuits with no
evidence of liquid spillage or
external port pin bent. Escalate
Burn evidence
55
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
B7 Chips(Including CID Yes
chips, silicon, ICs)
[B7C] [B7A]
56
B8 Components CID Yes
(Including
capacitors, [B8C]
resistors) [B8A]
Claim as CID if BATCH claims
burned/charred components
or Integrated Circuits with no
evidence of liquid spillage or
external port pin bent. Escalate
Lenovo Tech Team and reject
Burn Burn
the claims.
[B8D]
57
Unauthorized Repair.1-Wrong Parts on Board [R]
Issue Introduction
Issue CID Reported Issue Issue Causes Notes
Code Phenomenon
R Unauthorized Machine Cant Power On / Hang or Damage possibly caused due: Follow repairable/un-repairable
1,4,7,8 repair evidence Crash at Lenovo POST / Blue Screen Improper repair of PC by service people instruction.
including wrong (BSOD) / Battery Charge Failure or customer
parts on bard, /Display, keyboard, connectors not Follow cosmetic criteria for CID cosmetic
re-soldering, function, etc. inspection
jumping wire,
etc.
HR1 Foreign material HDD Error in POST / Can’t Detect HDD Damage possibly caused due: Follow repairable/un-repairable
on drive – while POST / Abnormal Noise from Improper repair of PC by service people instruction.
Foreign Label, HDD / Bad Sector or customer
Ink Mark on Follow cosmetic criteria for CID cosmetic
Label, Residual inspection
adhesive
58
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
R1 Board and Circuit CID No
[R1C] [R1R]
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
R7 Chips (Including chips, CID No
silicon, ICs)
[R7C] [R7R]
Re-Glue
59
R8 Components (Including CID No
capacitors, resistors)
[R8C] [R8R]
Re-Soldering
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
HR1-RA Hard drive CID No
60
HR1-FL Hard drive CID No
Foreign Label
[HR1FLC] [HR1FLR]
61
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
HR1-SI Hard drive CID No
[HR1SIC] [HR1SIR]
62
Label Damage-Label Missing or Damage [L]
Issue Introduction
Issue CID Reported Issue Issue Causes Notes
Code Phenomenon
L Label missing or / Damage possibly caused due: Follow repairable/un-repairable instruction.
1 damaged on Improper repair of PC by service people or
board which customer themselves Follow cosmetic criteria for CID cosmetic
impacted any Liquid spilt/burn/oxidation, etc. chemical inspection
identification of damage on label,
the part PN or
the barcode
LL1 Label missing or / Damage possibly caused due: Follow repairable/un-repairable instruction.
damaged on Improper repair of PC by service people or
panel which customer themselves Follow cosmetic criteria for CID cosmetic
impacted any Liquid spilt/burn/oxidation, etc. chemical inspection
identification of damage on label,
the part PN or
the barcode
63
HL1 Label missing or / Damage possibly caused due: Follow repairable/un-repairable instruction.
damaged on Improper repair of PC by service people or
hard drive customer themselves Follow cosmetic criteria for CID cosmetic
which impacted Liquid spilt/burn/oxidation, etc. chemical inspection
any damage on label,
identification of
the part PN or
the barcode,
Missing of Seal
label
64
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
L1 Board and Circuit CID No
Label Missing
[L1C] [L1R]
65
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
LCD Panel / LCD CID No
LL1-PB Module / LCD
Assembly [LL1PBC] [LL1PBR]
66
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
HL1-PO Hard Drive Label CID No
HDD Label been Peeled Off
[HL1POC] [HL1POR]
67
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
HL1-PS Hard Drive Label CID No
HDD Serial Number Barcode Peeled Off
[HL1PSC] [HL1PSR]
Note:
If the HDD label peels
off or the scratch was
smaller than those
pictures then we can
accept under Base
Warranty, else Reject
as CID
68
CID Code Defect Area Visual Examples of Issued CID CID Criteria ADP Support
HL1-SL Hard Drive Seal CID No
Drive Seal Label
Label
been Peeled Off
[HL1SLC] [HL1SLR]
69
Accidental Damage Protection (ADP) /
ThinkPad Protection (TPP)
Latest Terms and Conditions of ADP:
https://download.lenovo.com/lenovo/lsw/lenovo_pc_devices_services_agreement_feb2017-ap-english.pdf
70
e. Cosmetic damage (e.g., scratches, dents, or cracks that do not affect the product’s functionality or structural integrity);
i. Damage from abuse, misuse, unauthorized modification, unsuitable physical or operating environments, improper maintenance by anyone other than Lenovo-authorized
service providers, removal of original parts or alteration of product or identification labels;
ii. Damage caused by a product not covered under this Agreement or caused by biohazards or human or animal bodily fluids; or
iii. Theft, loss or damage from fire, flood, or natural disaster, war, terrorism, acts of God
1] Limitation of one replacement product. If the cost per claim exceeds the price of the product, the product will be replaced. Tablet claim cap: limited to one claim per 12 months.
2] This service is available in the country or region in which you purchased your Accidental Damage Protection coverage, and is not transferable should the system travel to another country.
3] If you are entitled to on-site warranty service under the Limited Lenovo Warranty, and the Service Provider determines your Product can be repaired at your location, then the Service
Provider will repair or exchange your product at your location. Some repairs may need to be completed at a service center. If so, the Service Provider will send the product to the service center
at its expense. If you purchase an on-site warranty with Accidental Damage Protection, on-site service level repairs will be limited to LCD and non-customer replaceable keyboards. If we
cannot complete the repair at the first on-site visit, then the system will be shipped to Lenovo’s Service Center to complete the repair. on-site service may not be available in all regions.
4] Cosmetic damage, e.g.: scratches, dents, or cracks that do not affect the product’s functionality or structural integrity. All products and offers are subject to availability.
71
5] Effective December 2014. Lenovo reserves the right to alter product offerings and specifications at any time, without notice. Lenovo makes every effort to ensure accuracy of all information
but is not liable or responsible for any editorial, photographic or typographic errors. All images are for illustration purposes only.
For full Lenovo product, service and warranty specifications visit www.lenovo.com. The following are trademarks or registered trademarks of Lenovo: Lenovo, the Lenovo logo, For Those Who
Do and ThinkPad.
Other company, product and service names may be trademarks or service marks of others. ©2016 Lenovo. All rights reserved.
Replacement Machine
If a replacement system is required, the customer will have the option to purchase a new ADP coverage for that new system, if desired. The coverage
for the original machine ceases when a replacement is provided. The coverage period terminates immediately if your Product is replaced under this
Agreement.
Repairs
ADP allows for ONE time repair per 12 months, i.e. one claim per year. Also, ADP allows for ONE time replacement per contracted year(s).
Limitation of one replacement product. If the cost per claim exceeds the price of the product, the product will be replaced. The ADP coverage period
terminates immediately if your Product is replaced under this Agreement.
72
Where is the Repair Performed?
If the machine is entitled to onsite services, the repair may be performed at customer’s site. If the problem cannot be resolved onsite, then the
machine may be repaired at our repair depot centers or it is also known as Customer Carry-In Services (CCI)*.
Waiting Period
When Service is purchased subsequent to the purchase of your Product, you may not exercise your rights to Service for thirty (30) days from the
purchase date of the Service. Lenovo reserves the right to inspect your Product prior to agreeing to provide Service, when Service is purchased
subsequent to the purchase of your Product.
73
End of
CID/SID Guideline