For the electronic measurement of currents: DC, AC, pulsed...,
with galvanic isolation between the primary circuit and the secondary
circuit.
16135
Features
Electrical data
●● Closed loop (compensated)
IPN Primary nominal current rms 200 A current transducer using the Hall
IPM Primary current, measuring range 0 .. ± 420 A effect
RM Measuring resistance @ TA = 70°C TA = 85°C ●● Isolated plastic case recognized
RM min RM max RM min RM max according to UL 94-V0.
with ± 12 V @ ± 200 A max 0 71 0 69 Ω
@ ± 420 A max 0 14 0 12 Ω Advantages
with ± 15 V @ ± 200 A max 0 100 23 98 Ω
●● Excellent accuracy
@ ± 420 A max 0 28 23 26 Ω
●● Very good linearity
ISN Secondary nominal current rms 100 mA
●● Low temperature drift
K N Conversion ratio 1 : 2000
●● Optimized response time
VC Supply voltage (+ 5 %) ± 12 .. 15 V
●● Wide frequency bandwidth
IC Current consumption @ ± 15 V 17 + IS mA
●● No insertion losses
●● High immunity to external
Accuracy - Dynamic performance data
interference
XG Overall accuracy @ IPN, TA = 25°C ± 0.5 % ●● Current overload capability.
εL Linearity error < 0.1 %
Applications
Typ Max
IO Offset current @ IP = 0, TA = 25°C ± 0.2 mA ●● AC variable speed drives and
IOM Magnetic offset current 1) @ IP = 0 and specified RM, servo motor drives
after an overload of 3 x IPN ± 0.1 mA ●● Static converters for DC motor
IOT Temperature variation of IO - 40°C .. + 85°C ± 0.12 ± 0.4 mA drives
tra Reaction time to 10 % of IPN step < 500 ns ●● Battery supplied applications
tr Response time 2) to 90 % of IPN step < 1 µs ●● Uninterruptible Power Supplies
di/dt di/dt accurately followed > 100 A/µs (UPS)
BW Frequency bandwidth (- 3 dB) DC .. 100 kHz ●● Switched Mode Power Supplies
(SMPS)
General data ●● Power supplies for welding
TA Ambient operating temperature - 40 .. + 85 °C applications.
TS Ambient storage temperature - 40 .. + 90 °C Application domain
RS Secondary coil resistance @ TA = 70°C 33 Ω
@ TA = 85°C 35 Ω ●● Industrial.
m Mass 78 g
Standards EN 50178: 1997
Notes: 1) The result of the coercive force (Hc) of the magnetic circuit
2)
With a di/dt of 100 A/µs.
Page 1/3
31October2011/version 16 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com
Current Transducer LF 205-S
Isolation characteristics
Vd Rms voltage for AC insulation test, 50/60 Hz, 1 min 3.5 kV
Vw Impulse withstand voltage 1.2/50 µs 8.8 kV
Ve Partial discharge extinction voltage rms @ 10 pC > 2 kV
Min
dCp Creepage distance 11 mm
dCI Clearance 10.2 mm
CTI Comparative Tracking Index (group IIIa) 175
Applications examples
Safety
When operating the transducer, certain parts of the module can carry hazardous
voltage (eg. primary busbar, power supply).
Ignoring this warning can lead to injury and/or cause serious damage.
This transducer is a build-in device, whose conducting parts must be inaccessible
after installation.
A protective housing or additional shield could be used.
Main supply must be able to be disconnected.