Sunteți pe pagina 1din 1

Page no.

Project

YOUR COMPANY LOGO Subject


Designed by
Checked by
Date 1/3/2020

DESIGN OF CORBEL BASED ON ( ACI-2002) (Grid "P" & "RB")


As
PROJECT Ref 11.9.0.0 AC1-02
350
COL LOCATION (For Precast Support)

Concrete f'c N/mm2 = 32

700
Steel fy N/mm2 = 420

Total ult load (Vu) 1328 KN


Col width bw = 1000 mm
Bearing pad
Allow bearing stress(ult) 0.75ff'c(N/mm2)= 16.8 N/mm2
Area of Pad(mm2)= 79,048 Length = 200 Area provided 100,000 mm2
Width = 500
Depth of corbel from shear(mm)

Vu=f*.2*fc*bw*d =
Depth required d= 244 mm
Cover to reinf c= 50 mm
Total Depth(mm) = 294 Provide 700 mm

Reinforcement
Moment Mu = Vu*a+Nu*(h-d) kN-m
where a= 50+2/3*width of pad= 183 mm
Nu=.2*Vu(kN) 265.6 kN
Moment Mu = = 257 kN-m
qn =Mu/bd2 = = 0.675 Rho = 0.00165
Af mm2 = 1073 mm2
Direct tension Reinf An Nu/ffy = 762 mm2

Shear friction Reinf Avf) Vu/ffym = 3811 mm2


Total Reinf As(mm ) is m=
2 1
greater of the following

a) As= (Af+ An)= 1835 mm2


b) As= (2/3*Avf+An)= 3304 mm2
c) As= min 2112 mm2

Dia of bars 25 6.73 Nos Provide 7

Shear Reinf mm2 Ah=.5*(As-An) 1271 mm2

16 6.32 Nos Provide 7