Sunteți pe pagina 1din 1

GENERAL NOTES

1. ALL DIMENSIONS ARE IN MM ONLY WRITTEN DIMENSION ARE TO


BE FOLLOWED. DIMENSIONS IN STRUCTURAL DRAWING SHOULD
NOT BE SCALED.
TRAP DOOR MACHINE ROOM BEAM SCHEDULE & REINF. DETAIL 2. STRUCTURAL DRAWING SHOULD BE READ IN CONNECTION WITH
RELEVANT ARCHITECTURAL DRAWING, IN CASE OF DISCREPANCY
BETWEEN ARCHITECTURAL AND STRUCTURAL DRAWING SHOULD
REINFORCEMENT STIRRUPS BE IMMEDIATELY BROUGHT TO NOTICE OF OFFICE OF SE(P),
WZ-(V)/SE, RCC,CPWD, RAIPUR.
TOTAL 3. M-25MIX- DESIGN MIX CONCRETE AND TMT BARS (FE-500D) SHALL
C/C WIDTH LEFT SUPPORT MID SPAN RIGHT SUPPORT LEFT SUPPORT MID SPAN RIGHT SUPPORT BE USED IN CONSTRUCTION.
SLAB DEPTH
S.NO. SPAN (mm)
BEAM (mm)
(m) B DIA LEG C/C DISTANCE DIA LEG C/C DISTANCE DIA LEG C/C DISTANCE
D TOP BOTTOM TOP BOTTOM TOP BOTTOM (mm) GED (mm) (m) X1 (mm) GED (mm) (m) X2 (mm) GED (mm) (m) X3 REINFORCING STEEL
1 M1 1.2 200 450 4-16Ø 3-16Ø 4-16Ø 3-16Ø 4-16Ø 3-16Ø 8Ø 2 100 As per 8Ø 2 100 As per 8Ø 2 100 As per
UP 2 M2 2.4 200 450 3-16Ø 3-16Ø 3-16Ø 3-16Ø 3-16Ø 3-16Ø 8Ø 2 100 typical
detail of
8Ø 2 150 typical
detail of
8Ø 2 100 typical
detail of beam
1. ALL REINFORCING STEEL WILL BE OF TESTED QUALITY
CONFIRMING TO IS: 1786 LATEST.
3 M3 3.6 200 450 3-12Ø 3-12Ø 3-12Ø 3-12Ø 3-12Ø 3-12Ø 8Ø 2 100 beam in 8Ø 2 150 beam in 8Ø 2 100 in 2. REFER TO HIGH YIELD STRENGTH DEFORMED BARS WITH
CHARACTERISTIC STRENGTH OF 500 N/SQ.MM.
4 M4 3.6 200 450 3-16Ø 3-16Ø 3-16Ø 3-16Ø 3-16Ø 3-16Ø 8Ø 2 100 8Ø 2 150 8Ø 2 100
Drawing Drawing Drawing No. 3. THE CLEAR COVER TO REINFORCEMENT SHALL BE AS FOLLOWS:-
No. No. FOUNDATION 50MM
DETAILS DETAILS COLUMNS 40MM
5 N1 1.2 200 450 4-12Ø 3-12Ø 4-12Ø 3-12Ø 4-12Ø 3-12Ø 8Ø 2 100 8Ø 2 100 DETAILS 8Ø 2 100
GRADE BEAM 50MM
6 N2 2.4 200 450 3-12Ø 3-12Ø 3-12Ø 3-12Ø 3-12Ø 3-12Ø 8Ø 2 100 8Ø 2 150 8Ø 2 100 WALL 50MM
FLOOR BEAM 30MM
H J K 7 N3 3.6 200 450 3-12Ø 3-12Ø 3-12Ø 3-12Ø 3-12Ø 3-12Ø 8Ø 2 100 8Ø 2 150 8Ø 2 100
SLABS 20MM*
8 N4 3.6 200 450 3-12Ø 3-12Ø 3-12Ø 3-12Ø 3-12Ø 3-12Ø 8Ø 2 100 8Ø 2 150 8Ø 2 100 * COVER TO SECONDARY REINFORCEMENT ALSO SHALL NOT BE
1200 2400 LESS THAN 20MM.

4. LAP LENGTH TO BE 50*DIA OF BAR MINIMUM.


M1 M2 5. SLAB BARS IN SHORTER DIRECTION SHALL BE BELOW BARS FOR
THE LONGER DIRECTION.
8 8 6. IN BEAMS, FIRST STIRRUP SHALL BE AT NO MORE THAN 40MM
FROM FACE OF THE SUPPORTING MEMBER.
7. IN BEAMS TOP BARS ARE NOT TO BE SPLICED IN THE END
QUARTERS OF THE SPAN, AND THE BOTTOM BARS ARE NOT TO BE
SPLICED AT MIDDLE HALF OF THE SPAN.

S1 S1 TABLE SHOWING DETAILS OF SLAB


REINFORCEMENT IN SLAB
M4
M3

M4
3600

3600

S. SLAB TYPE OF SLAB


SLAB
MAIN REINF. TOP EXTRA AT DISTRIBUTION # THIS DRAWING SHALL BE READ ALONG
NO. NO. THICKNESS
BOTHWAYS SUPPORT BAR WITH ARCHITECTURAL DRAWING NO. -
1. S1 TWO WAY 250 12 # @ 150 C/C 12 # @ 300 C/C 8 # @ 150 C/C

2. S2 TWO WAY 125 10 # @ 150 C/C 10 # @ 300 C/C 8 # @ 150 C/C


M1 M2
6 6
1200 2400

H J K

MACHINE ROOM TOP LVL.

H J K BEAM BEAM

1200 2400
N1 N2

2400
8 8

1900
TRAP DOOR REVISION DATE CHANGE
MACHINE ROOM BOTTOM LVL.
SIGN. OF VETTING AUTHORITY
S2 S2 BEAM
DETAIL OF EXTRA REINF. AROUND BEAM
N4
N3

N4
3600

3600

OPENING IN SLAB

1050
600

600
FL.LVL.
TERRACE FLOOR LVL.

N1 N2 SIGN. OF STRUCTURAL CONSULTANT


6 6
1200 2400 SLAB REINF.

SECTION E-E
H J K
REFERENCE DRAWINGS NO.
1. ARCHITECTURAL

STRUCTURAL DRAWING
PROJECT: Structural Consultants : DWG.TITLE: SCALE REVISION DATE
PROPOSED VVPAT STORAGE BUILDING Architect : STRUCTURAL ENGINEER VVPAT
15 OCT '19
TEKNO ENGINEERING CONSULTANTS
VVPAT UNIT AT DURG (C.G)
A-15, Sector - 01, Shankar Nagar MACHINE ROOM DETAILS N.T.S R0 DWG. NO.
CGPWD SARVOTTAM MUNJWANI
CLIENT: Above Jaya Medical, Raipur - 492001 TEC / CGPWD-DURG/ VVPAT / LIFT /
CHHATTISGARH PUBLIC WORKS DEPARTMENT M.TECH(STRUC) IIT DELHI, B.E. (CIVIL) DRAWN DESIGN CHECKED
Telephone +91 771 - 4051331 ST -25
EXECUTIVE ENGINEER, DURG DIVISION TEC Mobile +91 8871738000 , +91 9893033353 SANDEEP SARVOTTAM SARVOTTAM