Sunteți pe pagina 1din 1

USP

MICROCODE VERSION 50-05-28-00/00


RELEASED 04/14/06

Newly supported features and functions for Version 50-05-28-00/00


NONE

The change of contents for Version 50-05-28-00/00


1 WCHK1 Occurred when Invalid Frame Received
Phenomena When an Invalid frame was received from host interface, WCHK1
occurred on CHP (CHF processor).
Severity (High, Medium, Low) High
Conditions of Occurrence This problem occurs when all the following conditions (A-D) are met.
A. USP/NSC (XP12000/XP10000)
B. Receiving an invalid frame (Frame CRC error etc.)
C. CHF PCB (8HSR/16HS/16HSR/32HS/32HSR/32FSR)
D. SSB B408 is output
Affected Products/Version DKCMAIN: All
Fixed Product/Version DKCMAIN: 50-05-28-00/00
Category OPEN
Changed Part DKCMAIN

2 Added NAS Guard Logic for Improper Pair RESYNC


Phenomena During an IMPORT of the secondary volume with True Copy (TC),
Shadow Image (SI), or Universal Replicator (UR) in NAS Blade, if a
RESYNC performs without deleting the target file system by improper
operation, the system management information in the primary and the
secondary volumes and the management information in the NAS OS
become inconsistent. As a result, the file system cannot be mounted.
Severity (High, Medium, Low) High
Conditions of Occurrence This problem occurs when all the following conditions are met.
A. RAID500 (ALL versions)
B. Using SI, TC, or UR in NAS Blade
C. During an IMPORT of the secondary volume, perform a pair RESYNC
without deleting the target file system
D. After above C, a failover occurs, or the NAS OS is rebooted.
Causes and Updates Improper pair RESYNC operation with SI, TC, or UR in NAS Blade
The micro-programs have been modified to prevent the improper pair
RESYNC operation from being performed in this case.
Affected Products/Version DKCMAIN/SVP: All
Fixed Product/Version DKCMAIN: 50-05-28-00/00
SVP: 50-05-24/00
NAS OS: 03-05-01
Category NAS
Changed Part DKCMAIN/ SVP/ NAS

HDS Confidential 1 of 1