Land Transport Main Roads Division QA/QC Form

Date: 04-09/09/2018 Laboratory


Type of Mix: A/C Wearing Course Contractor: BIN HAFEEZ GEN. CONT
Type of Test: Asphaltic Concrete Marshall Data Test Method: [] ASTM D 1559 Report Ref: N/A IR No. : N/A
Location: Mafraq Asphalt Plant

Bitumen (AC) Grade: 60/50 (GB) 1.0371 (GSB) 2.909 (GSE) 2.926
Flow Stiffness
Weight of Sample g Density Volume Total % Voids % Specimen Hight Stability
% A.C % A.C Bulk Reading kN/mm
No. by Wt. by Wt. Dry volum Measured
Corrected
of Agg of Mix SSD in Sample In e M3 Bulk Max A.C Ag. Voids Ag. Filled Total mm Correction Reading mm
Air Water Theo. Mix Factor
in Air kN Kgf Kgf
1 1303.7 1294.5 790.2 513.5 2.521 1.00 13.25 1351 1351 2.45 551
2 1304.9 1296.1 789.5 515.4 2.515 1.00 16.01 1633 1633 2.50 653
3 1303.5 1296.6 791.8 511.7 2.534 1.00 13.83 1410 1410 2.30 613

Average 3.0 2.523 2.774 7.3 84.1 8.6 15.9 43.4 9.0 14.36 1465 1465 2.4 606
1 1305.2 1298.8 797.5 507.7 2.558 1.04 16.59 1692 1760 2.30 765
2 1308.5 1301.3 798.6 509.9 2.552 1.00 15.30 1560 1560 2.60 600
3 1305.7 1299.0 793.2 512.5 2.535 1.00 16.93 1726 1726 2.60 664

Average 3.5 2.548 2.751 8.6 84.5 6.9 15.5 52.3 7.4 16.27 1659 1682 2.5 676
Remarks:

Contractor.: Consultant.:
Lab technician.: Material Eng.: Material Inspector.: Material Eng.:

Page 1 of 1 QA/QC SL­22
Land Transport Main Roads Division QA/QC Form

Date: 04-09/09/2018 Laboratory


Type of Mix: A/C Wearing Course Contractor: BIN HAFEEZ GEN. CONT
Type of Test: Asphaltic Concrete Marshall Data Test Method: [] ASTM D 1559 Report Ref: N/A IR No. : N/A
Location: Mafraq Asphalt Plant

Bitumen (AC) Grade: 40/50 (GB) 1.0371 (GSB) 2.909 (GSE) 2.926
Flow Stiffness
Weight of Sample g Density Volume Total % Voids % Specimen Hight Stability
% A.C % A.C Bulk Reading kN/mm
No. by Wt. by Wt. Dry volum Measured
Corrected
of Agg of Mix SSD in Sample In e M3 Bulk Max A.C Ag. Voids Ag. Filled Total mm Correction Reading mm
Air Water Theo. Mix Factor
in Air kN Kgf Kgf
1 1312.2 1308.8 801.2 511.0 2.561 1.00 17.88 1823 1823 3.20 570
2 1313.8 1310.1 805.1 508.7 2.575 1.04 16.62 1695 1763 2.80 630
3 1313.4 1309.4 804.5 508.9 2.573 1.04 20.85 2126 2211 3.00 737

Average 4.0 2.570 2.727 9.9 84.8 5.3 15.2 61.8 5.8 18.45 1881 1932 3.0 646
1 1318.1 1315.5 812.6 505.5 2.602 1.04 19.63 2002 2082 3.55 586
2 1318.4 1316.6 810.3 508.1 2.591 1.04 17.25 1759 1829 3.90 469
3 1319.3 1317.3 813.2 506.1 2.603 1.04 17.02 1736 1805 3.40 531

Average 4.5 2.599 2.704 11.3 85.3 3.4 14.7 73.5 3.9 17.97 1832 1905 3.6 529
Remarks:

Contractor.: Consultant.:
Lab technician.: Material Eng.: Material Inspector.: Material Eng.:

Page 1 of 1 QA/QC SL­22
Land Transport Main Roads Division QA/QC Form

Date: 04-09/09/2018 Laboratory


Type of Mix: A/C Wearing Course Contractor: BIN HAFEEZ GEN. CONT
Type of Test: Asphaltic Concrete Marshall Data Test Method: [] ASTM D 1559 Report Ref: N/A IR No. : N/A
Location: Asphalt Plant Mafraq

Bitumen (AC) Grade: 40/50 (GB) 1.0371 (GSB) 2.909 (GSE) 2.926
Flow Stiffness
Weight of Sample g Density Volume Total % Voids % Specimen Hight Stability
% A.C % A.C Bulk Reading kN/mm
No. by Wt. by Wt. Dry volum Measured
Corrected
of Agg of Mix SSD in Sample In e M3 Bulk Max A.C Ag. Voids Ag. Filled Total mm Correction Reading mm
Air Water Theo. Mix Factor
in Air kN Kgf Kgf
1 1326.0 1324.8 817.5 508.5 2.605 1.04 15.23 1553 1615 3.80 425
2 1322.8 1322.0 816.8 506.0 2.613 1.04 17.92 1827 1900 4.30 442
3 1324.5 1323.6 816.1 508.4 2.603 1.04 16.80 1713 1782 4.30 414

Average 5.0 2.607 2.682 12.6 85.1 2.3 14.9 81.2 2.8 16.65 1698 1766 4.1 427
1 0.0 ### 1.04 0 0 #DIV/0!
2 0.0 ### 1.04 0 0 #DIV/0!
3 0.0 ### 1.04 0 0 #DIV/0!

Average ### 2.926 ### ### ### ### ### ### ### 0 0 #DIV/0! #DIV/0!
Remarks:

Contractor.: Consultant.:
Lab technician.: Material Eng.: Material Inspector.: Material Eng.: