Sunteți pe pagina 1din 3

Pipe with fan interpolation for air density

given data/ name unit

area 0.05406 m2
length 0.0456 m
weight 54 kg

trial 1 trial 2
heater temperature 310.25 K 321.15
power 42 W 85
air temperature 299.15 K 299.25
Pressure drop ∆p 0.43 mbar 0.42
∆T 11.1 K 21.9
α 69.9923008469 71.7957554349
density 1.16527 kg/m3 1.1648895
velocity w 8.54 m/s 8.54
heat capacity 1.0073 1.007305
kinematic viscosity 0.000015667 0.000015676
thermal conductivity 0.026468 0.0246753
Reynold number 24856.3222059105 24842.0515437612
Nusselt number 120.5851941446 132.6786887225
n for air density interpolation for viscosity
T in C air density in kg/m3 T in C v in m2/s*10^-6
20 1.1881 20 15.13
40 1.112 40 16.92
trial 1 trial 1
26 1.16527 26 15.667
trial 2 trial 2
26.1 1.16489 26.1 15.676
trial 3 trial 3
26.2 1.164509 26.2 15.685

trial 3
330.35
121
299.35
0.42
31
72.2017352285 interpolation for heat capacity
1.164509 T in C
8.54 20
1.00731 40
0.000015685 trial 1
0.0265 26
24827.7972585273 trial 2
124.2414764686 26.1
trial 3
26.2
interpolation for thermal conductivity
T in C λ in W/K.m
20 0.02603
40 0.2749
trial 1
26 0.026468
trial 2
26.1 0.0246753
trial 3
26.2 0.0265

for heat capacity


Cp in kJ/kg*K
1.007
1.008

1.0073

1.007305

1.00731

S-ar putea să vă placă și