Sunteți pe pagina 1din 2

Aquaculture Aquaculture Aquaculture

Biobrane Biobrane Biobrane Protect Biobrane Standards


Aqua 1050 Aqua 1550 Aqua 2050 Meshes 332 Activ 1002
Flexible semi closed cage system (SCCS) Technical properties
Flexible semi closed cage Weight 1 050 g/m² 1 500 g/m² 2250 g/m² 340 g/m² 1 050 g/m² EN ISO 2286-2
system (SCCS)
Width 267 cm 180 cm 178 cm 267 cm 267 cm -
Tensile strength 400/400 daN/5 cm 1 000/800 daN/5 cm 1300/1300daN/5 cm 230/160 daN/5 cm 430/430 daN/5 cm EN ISO 1421
(warp/weft)
Department of fisheries ask you to reduce fish escape risk, collect the sludge and improve fish welfare? Tear strength 55/50 daN 200/180 daN 150/250 daN 30/15 daN 55/50 daN DIN 53.363
(warp/weft)
Here is the most cost-efficient solution to produce robust fishes together with a drastic decrease of external threats. Adhesion 12 daN/5 cm 15 daN/5 cm 25 daN/5cm 7 daN/5cm 12 daN/cm EN ISO 2411
It is the smartest way to farm fish with the quickest return on investment compared to standard open net pens and
land-based facilities that are expensive solutions when used for a full cycle of fish-growth. Characteristics 100% blackout Coating certified non toxic for fish Porosity 14% Antibacterial -

Hight 6 Certifications
Norm - NS 9415 NS 9415 - OCDE 203 - ASTM E 2180 -
5

4
Flame retardancy

Double wall
Filters

3 M1/NFP 92-507
B1/DIN 4102-1 M2/NFP 92-507
Rating - - - -
2 G1/GOST 30244-94 B1/DIN 4102-1
Telescopic

Serge Ferrari and Biobrane are registered


VKF 5.3/SN 198898

trademarks of Serge Ferrari sas.


Euroclass - - B-s2,d0/EN 13501-1 B-s2,d0/EN 13501-1 -

9223 - Septembre 2018 - V3.01


-

Low 0
s y y
ru ) lit lit tio
n op isk tio ce
Vi D... bi kes) ta llu dr r Ra na
n
/
s G a
st a or O2 pe n te Labels, guarantees, recycling
ite , A e int m Po / ca io
r Las ice t ur ter ish ing Es er
s ain
ul h nv M 3 years

S
Pa RS, ra wa F
Fis
/
ia S peopic Fo co guarantee

GB
With S+, Serge Ferrari goes further than the Standards...
r , m d
cte loom te sc ee Biobrane (consult us for further information)

/Ba (B al tele F Aqua 2050


ae tim s to
Al
g Op ank Standard Flexible semi
(th
open cage closed cage The technical data above are average values with a +/- 10% tolerance. The buyer of our products is fully responsible for their application or their transformation concerning any
possible third party. The buyer of our products is responsible for their implementation and installation according to the standards, use and customs and safety rules of the countries
where they are used. For information on our contractual warranty, please refer to the relevant terms and conditions. The values quoted above represent results of tests performed
in compliance with common design practices and are provided for only to enable customers to make the best use of our products. Our products are subjects to evolutions due to
technical progress, we remain entitled to modify the characteristics of our products at any time. The buyer of our products is responsible for checking the validity of the above data.

«Our research shows that consumers are more and more demanding for fish certifications and expect
their fish farmers to be aligned with their expectations. Quality Warning
Serge Ferrari is leading the way with a strong believe in sustainable technologies insuring a low The use of reinforced membranes for fish farming makes sense today but in order to warranty longevity and reliability
environmental footprint. in the specific application of semi closed cages, there are some quality issue to be aware of:
- The adhesion between the coating (PVC or TPU) and the base fabric (polyester) is key for the seams longevity: fatigue
This is why flexible sea based closed system represents the best solution available on the market today.»
can happen thanks to loads from waves and current. There is a risk of delamination especially if the coating is

Photo : Thinkshell, Botngaard - DPS Lovenly


calendered.
- Elongation: if you consider a positive pressure into the cage to maintain its shape tensioned, the membrane needs
Serge Ferrari is world leader of innovative membranes with a solid experience in fish farming to behave with very low elongation and keep its shape as defined. If not, the cage will be potato like and the
applications and has come up with its most durable solution. overpressure will be hard to maintain.
Serge Ferrari composite materials are the most adapted thanks to the Precontraint technology. They enable very low
_O
 ur technology is tried and tested since 2015 and 3 cycles in Norway and it comes with a strong
elongation under loads, comply with the Norwegian Standard NS 9415 and come with strong warranties!
warranty and lifetime expected over 10 years!
_O
 ur worldwide network of installers can provide the most performing service close to your
working area.
_ F ew other prototypes have been tested around the world with some severe breakdowns
especially with rigid closed systems that cannot absorb the loads of waves. This flexible solution
is adapted to semi exposed location with high Hs and Vc. Serge Ferrari SAS
+ 33 (0)4 74 97 41 33
sergeferrari.com
AQUACULTURE: Protect the fish. Preserve the sea.

BLACK OUT COVER FOR HATCHERY

SLAUGHTERY
SOLAR PROTECTION FOR EXTERNAL SMOLT TANKS DEDICATED COVERS
FLEXIBLE SELF
STANDING COVER
WAITING CAGE FOR
CLOSED CAGE BROODSTOCK
Postsmolt &
Ongrowth

FRESH WATER TOW BAG

FRESH WATER DEPOT


FLEXIBLE & TELESCOPIC HOSE

PATENTED
TECHNOLOGY

BLACK OUT COVER FOR HATCHERY FRESH WATER DEPOT / FLEXIBLE TANKS CLOSED CAGE FLEXIBLE TELESCOPIC INTAKES SPECIAL COVERS FOR SLAUGHTERY: ODOR, DUST, BACTERIAL CONTAMINATION

Artificial lighting to improve growth rate from Save operating costs from wellboat with huge Flexible closed cage technology to grow fish A patented technology to pump water from Translucent and antistatic roof for halls Antibacterial translucent covers for waste
egg to smolt. flexible and floating fresh water tanks to be towed or from smolt to harvest without sealice, mortality, different depths for an optimal temperature: with a special surface treatment against UV treatment tanks, waterproof, odor proof,
installed on location with a capacity up to 10 000 m . 3 predator threats and fish escape risk. 80 m below the sea level. aging, moisture and dust. flame retardant and chemical resistant.
It is also possible to use for SCCS in protected location.

Biobrane Aqua 1050-50275 Biobrane Aqua 1550-1071 Biobrane Aqua 2050-1071 FTH: Flexible Telescopic Hose Protect Meshes 332-50201 Biobrane Activ 1002-50800

S-ar putea să vă placă și